• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 3
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influencia de superplastificantes, ultra-som e revestimento com silicato de sodio nas propriedades de concreto

Rodrigues, Flavio Aparecido 14 July 2018 (has links)
Orientador : Ines Joekes / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-14T01:41:20Z (GMT). No. of bitstreams: 1 Rodrigues_FlavioAparecido_M.pdf: 4891674 bytes, checksum: 14b402c0d1dc2be145f14f42d04c1664 (MD5) Previous issue date: 1991 / Mestrado
2

Taliscas de bambu em matrizes de concreto : caracteristicas fisico-mecanicas

Argollo Ferrão, André Munhoz de, 1965- 15 December 1992 (has links)
Orientador : Wesley Jorge Freire / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-07-18T11:39:56Z (GMT). No. of bitstreams: 1 ArgolloFerrao_AndreMunhozde_M.pdf: 3513941 bytes, checksum: aed159571f6e512ada084bfbc43052e6 (MD5) Previous issue date: 1992 / Mestrado / Mestre em Engenharia Agrícola
3

Analise numerica de vigas de concreto de alta resistencia considerando a não-linearidade fisica

Soriano, Julio, 1967- 06 August 1996 (has links)
Orientador: Aloisio Ernesto Assan / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-21T14:32:20Z (GMT). No. of bitstreams: 1 Soriano_Julio_M.pdf: 2636023 bytes, checksum: 766ac59fe762c572aece3f1447b7687c (MD5) Previous issue date: 1996 / Resumo: Resultados experimentais de vigas em Concreto de Alta Resistência são confrontados com aproximações numéricas resultantes do programa ROOF, o qual sofreu alterações em algumas de suas rotinas de cálculo para representar o comportamento desse material. Algumas relações constitutivas indicadas por pesquisadores do CAR foram apreciadas e empregadas nesse trabalho. Aplica-se o método dos elementos finitos considerando-se a não-linearidade do material e resolução do sistema pelo método iterativo de Newton-Raphson. Para para incremento de carga obtém-se como resultados delocamentos, tensões e deformações ao concreto e do aço, bem como informações concementes ao processo de fissuração. ...Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: Test results for high-strength concrete beams are compared with numerical values obtained with the computer code ROOF. Some routines of this finite element code were adapted to represent the behavior of such material. Constitutive relationships proposed by several investigators of the high-strength concrete properties were analized and employed in this work. The finite element method was used taking into account the nonlinear material behavior of the concrete. The solution of the nonlinear problem was performed using the Newton-Raphson technique. For each load increment information concemed with displacements, stresses and strains in concrete and steel points are available as well as the distribution of the cracking along the beam length. ...Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Estruturas / Mestre em Engenharia Civil
4

Contribuição ao estudo das lajes mistas protendidas

Almeida, Audrey Gregori Melchert de 08 July 1998 (has links)
Orientador: Luiz Roberto Sobreira de Agostini / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-24T13:57:21Z (GMT). No. of bitstreams: 1 Almeida_AudreyGregoriMelchertde_M.pdf: 2945704 bytes, checksum: 307b35c63c16d7b0aee456c48a30ad5b (MD5) Previous issue date: 1998 / Resumo: Apresenta-se neste trabalho um procedimento de verificação do dimensionamento de lajes mistas protendidas, compostas por vi gotas pré-moldadas com seção transversal em forma de PI invertido, protendidas pelo sistema de pré-tração e complementadas na obra com o lançamento de concreto local. Foram previstos na fase de construção três casos de escoramento com 0,1 ou 2 estais. Assim, desenvolveu-se uma rotina para a verificação automatizada destas lajes. Apresenta-se também o método das fibras de fluência utilizado na determinação das perdas de protensão, o problema da retração diferencial e o cálculo das perdas progressivas, importantes para este tipo de estrutura / Abstract: This dissertation presents a procedure to verify the calculation of composite prestressed concrete slabs. This is formed by precast beams with inverted PI cross section, prestressed by the pretensioning system and finished in the construction site with local concrete. Were foreseen three supportable cases in the construction stage with O, 1 or 2 supports. Therefore, it was developed a program to automatized verification of these slabs. Were also considerate in the determination of the losses of prestress the fibers of creep method, the problem of differential shrinkage and progressives losses, very importants for this kind of structure / Mestrado / Estruturas / Mestre em Engenharia Civil
5

INFLUÊNCIA DO TAMANHO DO CORPO DE PROVA NOS RESULTADOS DE ENSAIOS DE MÓDULO DE DEFORMAÇÃO E RESISTÊNCIA À COMPRESSÃO E SUAS CORRELAÇÕES PARA CONCRETOS PRODUZIDOS EM GOIÂNIA - GO / INLUENCE OF THE SIZE OF THE SPECIMEN IN THE RESULTS OF THE TESTS OF MODULUS OF ELASTICITY AND COMPRESSIVE STRENGTH AND THEIR CORRELATIONS FOR CONCRETE MADE IN GOIÂNIA GO

MARTINS, Danilo Gomes 03 October 2008 (has links)
Made available in DSpace on 2014-07-29T15:03:32Z (GMT). No. of bitstreams: 1 dissertacaoDanilo.pdf: 2147690 bytes, checksum: c918dd24c275d43fcca4fc1283e857a6 (MD5) Previous issue date: 2008-10-03 / Even though the different sizes of cylindrical specimens for tests in concrete are standardized to get the simple compressive strength and the modulus of elasticity, this factor is not usually studied in most researches. So, the goal of this thesis was to evaluate the influence of the size of the specimens in the initial tangent modulus of elasticity (Eci) and in the compressive strength (fc), correlate the values of fc and Eci, and compare the values of modulus of elasticity that were estimated by the equations proposed by the Brazilian code (NBR 6118/2003) and by the American norm (ACI 318/2002). Concretes with three levels of strength were used after 28 days: 25MPa, 30MPa and 40MPa. They were all proportionally mixed with materials of the region and supplied by only one concrete batching plant of Goiânia GO. The tests of compressive strength and initial tangent modulus of elasticity were done in cylindrical specimens of 100 x 200 mm and 150 x 300 mm after 28 days. The samples were collected during the delivery of the concrete in the construction sites. For each truck, ten specimens were molded, five of 100 x 200 mm and five of 150 x 300 mm. Of the 600 specimens that were molded, 240 tests of compressive strength and 360 tests of modulus of elasticity were done. The cure was in a tank with water saturated with limestone. After the tests were done, the statistical analysis of the results was done. The variance analysis (ANOVA) indicated that the size of the specimen exerts influence only on the results of the initial tangent modulus of elasticity (Eci). There is a tendency for the specimens of 100 x 200 mm to show greater results for the modulus of elasticity of the concrete than the specimens of 150 x 300 mm. In the compressive strength, only the level of strength significantly exerted influence on the results. It was also observed that the NBR 6118/2003 overestimates the values of modulus of elasticity of the researched concretes and the results are better adequate to the model proposed by the ACI 318/02. / Apesar dos parâmetros de ensaios, como o tamanho do corpo de prova, influenciarem nos resultados do módulo de deformação e da resistência a compressão, normalmente esse fator não é estudado na maioria das pesquisas. Assim, esta dissertação objetivou avaliar a influência do tamanho dos corpos de prova no módulo de deformação tangente inicial (Eci), e na resistência a compressão (fc), correlacionar os valores de fc e Eci e comparar os valores de módulo de deformação alcançados com os valores estimados pelas equações propostas pela norma brasileira (NBR 6118/2003) e pelo amaericana (ACI 318/2002). Utilizaram-se concretos com três níveis de resistência aos 28 dias: 25MPa, 30MPa e 40Mpa, todos dosados com materiais da região e fornecidos por uma mesma central de concreto de Goiânia - GO. Os ensaios de resistência à compressão e de módulo de deformação tangente inicial foram realizados em corpos de prova cilíndricos de 100 x 200 mm e 150 x 300 mm aos 28 dias. As amostras foram coletadas durante a entrega do concreto nas obras. A cada caminhão, eram moldados dez corpos de prova, cinco de 100 x 200 mm e cinco de 150 x 300 mm. Foram moldados 600 corpos de prova, onde realizaram-se 240 ensaios de resistência à compressão e 360 de módulo de deformação. A cura foi em tanque com água saturada com cal. Após a realização dos ensaios, fez-se a análise estatística dos resultados obtidos. A análise de variância (ANOVA) indicou que o tamanho do corpo de prova exerce influência apenas nos resultados do módulo de deformação tangente inicial (Eci). Houve uma tendência dos corpos de prova de 100 x 200 mm apresentarem maiores resultados para o módulo de deformação do concreto que os corpos de prova 150 x 300 mm. Na resistência à compressão, como já era esperado, apenas a classe de resistência influenciou significativamente nos resultados. Observou-se também que a NBR-6118/2003 superestima os valores de módulo de deformação dos concretos estudados e que os resultados obtidos se adequam melhor ao modelo proposto pelo ACI318/02.

Page generated in 0.0571 seconds