• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2872
  • 668
  • 28
  • 11
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • Tagged with
  • 3605
  • 1860
  • 1287
  • 920
  • 799
  • 633
  • 577
  • 415
  • 398
  • 380
  • 373
  • 362
  • 362
  • 362
  • 362
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Apoio e carregamento indiretos em vigas de concreto de alta resistencia

Ribeiro, Flavia Conceição Veneziani 24 May 1999 (has links)
Orientador: Gilson Battiston Fernandes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-25T02:43:35Z (GMT). No. of bitstreams: 1 Ribeiro_FlaviaConceicaoVeneziani_M.pdf: 3834401 bytes, checksum: 42faf6a148fd530d36c45b319152b048 (MD5) Previous issue date: 1999 / Resumo: Este trabalho aborda as situações de apoio e carregamento indiretos em vigas de concreto de alta resistência. A parte experimental consistiu no ensaio de três conjuntos de vigas, apoiada e suporte, de mesmas dimensões, em forma de T no plano horizontal. As vigas foram ensaiadas com arranjos de armadura de suspensão e carregamentos distintos. Foi analisado o comportamento das vigas e armadura dando ênfase à armadura de suspensão disposta na região de interseção entre as vigas. Os resultados obtidos mostram que uma armadura concentrada na região de volume comum às duas vigas é mais eficiente para a transmissão dos esforços na interseção / Abstract: This research deals with the situations of indirect loading and indirect supporting in beams of high strength concrete. The experimental study consisted in tests of three horizontal T-shaped specimens, composed by supported and supporting beams. The loading and hanger reinforcement arrangements were different in the tests. The behavior of beams and reinforcement was studied emphasizing the hanger reinforcement at the intersection of the beams. Tests demonstrated that a reinforcement placed within the common volume is more efficient to transfer the loads at the intersection / Mestrado / Estruturas / Mestre em Engenharia Civil
32

Evaluación de la Puzolana Natural del Distrito de Chongos Alto como adición en la elaboración de concretos para F ́C=175, 210, 245 Kg/cm2- Huancayo- 2016

Giraldez Candiotti, Lilia Fiorella 09 February 2018 (has links)
En la búsqueda por reducir el impacto de contaminación del cemento, se plantean diversas soluciones que permitan reducir la contaminación ya sea durante la fabricación o uso del producto (cemento), encontrando en las adiciones minerales como la puzolana natural un considerable reemplazo del cemento, ya que mientras menos cemento se use menos será la contaminación. En esta investigación se ha realizado el estudio y análisis de la puzolana natural del distrito de Chongos Alto en el comportamiento del concreto en estado fresco como endurecido, ya que al adicionar la puzolana natural se sustituye parcialmente la cantidad de cemento. Para tal fin se desarrolló una mezcla patrón para cada F’c= 175 kg/cm2 , 210 kg/cm2 y 245 kg/cm2 con los siguientes componentes: cemento Portland tipo IP + agregados + agua.
33

Avaliação do comportamento eletroquímico de sistemas de reparo para estruturas de concreto com corrosão de armaduras. / Evaluation of electrochemical behavior of repair systems for concrete structures with reinforcement corrosion.

Grochoski Garcia, Maurício Luiz 14 April 2008 (has links)
A cada dia os custos econômicos e sociais da corrosão de armaduras nas estruturas de concreto armado têm se tornado mais significativos nas economias dos países, tanto desenvolvidos, quanto em desenvolvimento. Em 2004, a Alemanha gastou aproximadamente 90 bilhões de euros com manutenção e reparo de estruturas de concreto armado, o correspondente a 50% do total gasto na construção civil deste país. Essa parcela é ainda maior no caso da Itália, onde chega a 57% (UEDA & TAKEWAKA, 2007). Esses gastos mostram o crescimento do mercado mundial de reparo e proteção de estruturas de concreto. Esse mercado já conta com várias soluções disponíveis e a cada dia novos produtos surgem, e outros tantos estão em estudo, seja para a prevenção ou para terapia da corrosão. Diante dessa gama de produtos e sistemas para prevenção e reparo, os engenheiros responsáveis por prescrevê-los para as obras de recuperação, reforço e proteção, precisam conhecer adequadamente o seu comportamento e sua real eficácia, ou seja, precisam dispor de metodologias para bem avaliar a viabilidade técnica e econômica dos sistemas e dos produtos disponíveis. O estudo desenvolvido durante esta tese procurou, de forma bastante abrangente, avaliar o comportamento eletroquímico, em campo e em laboratório, de seis diferentes sistemas de reparo para estruturas de concreto com corrosão de armaduras, com características bastante distintas. Em campo foi proposto e aplicado um método deavaliação e comparação destes sistemas, utilizando como parâmetros o potencial e a intensidade de corrosão. Em laboratório, além destes parâmetros eletroquímicos, outros parâmetros físicos e mecânicos também foram avaliados. ) Os resultados obtidos em campo mostraram tendências de comportamento bastante interessantes dos sistemas de reparo avaliados, que, apesar do prazo curto para a realização do experimento (2 anos), permitiram extrair algumas informações importantes acerca do comportamento destes na situação real de uso. Além disso, esta pesquisa mostrou que o método de avaliação aqui proposto é bastante promissor. Os resultados de laboratório, além de contribuir para o entendimento do comportamento dos diferentes sistemas, mostraram a complexidade da avaliação dos sistemas de reparo e a necessidade de consideração das variáveis importantes no problema. / Social and economic costs due to reinforcement corrosion are becoming even more significant all over the world, in developed countries and also in under development ones. In 2004, Germany has spent approximately 90 billion euros with maintenance and repair of concrete structures, what corresponds to 50% of all money spent on Germany\'s civil construction sector. In Italy, this percentage is even greater, reaching 57% (UEDA & TAKEWAKA, 2007). These facts show an increase in the world market of maintenance and repair of concrete structures. There are already many maintenance and repair solutions available and there are more solutions being released every day. Due to this great diversity of solutions, the engineer responsible for recommending their use, must know properly their behavior and real efficiency. This study aimed to evaluate the electrochemical behavior of six different repair systems for concrete with reinforcement corrosion, on-site and in the laboratory. On site an evaluation and comparison method based on corrosion potential and intensity was proposed and applied. In the laboratory, besides these parameters, physical and mechanical ones were also evaluated. Despite the experiment\'s short duration (2 years), the on-site results showed interesting behavior trends for the evaluated systems, allowing some important information about them to be extracted. Nevertheless, the proposed method has showed itself to be very promising. The results obtained in thelaboratory have made great contribution on understanding the systems repair\'s behaviors. Furthermore they showed the complexity of this theme and the necessity of consideration of all playing variables.
34

Caracterización mecánica del concreto usando ensayos no destructivos de resonancia por impacto y vibración ambiental

Gonzales Paliza, Edson Mauricio 24 September 2016 (has links)
Este trabajo explora el manejo de métodos no destructivos para la caracterización mecánica y evaluación de la calidad de concretos de mediana resistencia. Los métodos no destructivos tomados en cuenta para esta investigación fueron el ensayo de resonancia por impacto y el ensayo de vibración basado en respuestas ambientales. Los ensayos de resonancia por impacto fueron comparados con el ensayo de resistencia a la compresión en dos campañas experimentales. La primera campaña se llevó a cabo en 20 especímenes de concreto fabricados y curados en laboratorio, con el propósito de realizar un monitoreo continuo del desarrollo del módulo de elasticidad dinámico del concreto en el tiempo. En la segunda campaña, se evaluaron 265 especímenes provenientes de diferentes proyectos de la ciudad de Lima, con finalidad de obtener una correlación entre el módulo de elasticidad dinámico y la resistencia a la compresión. Las correlaciones preliminares fueron validadas en 181 especímenes adicionales. Por otra parte, los ensayos de vibración ambiental se aplicaron para monitorear de forma continua el desarrollo del módulo de elasticidad estático del concreto desde el momento del vaciado. Estos resultados se compararon con los obtenidos en laboratorio a través del método tradicional de lectura del módulo de elasticidad de cuerda. Además se analizó la relación entre el módulo de elasticidad dinámico y el módulo de elasticidad estático del concreto. La aplicación de ensayos no destructivos son de gran interés en el campo de la mecánica de materiales. En el caso del concreto permiten determinar algunas propiedades mecánicas, desde edades muy tempranas, de forma rápida y sin la necesidad de realizar largas y costosas campañas de laboratorio. / Tesis
35

Resistência à tração de diferentes tipos de ancoragens embutidas em elementos de concreto armado / Tensile behavior of differents types of anchors embedded in reinforced concrete

Silva, Patrícia Cândida Souza da 20 July 2018 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2018. / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) e Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES). / Este trabalho refere-se à análise do desempenho de diferentes ancoragens pré-instaladas em estruturas de concreto armado e submetidas à tração direta. Para isso, foram realizados 34 ensaios de arrancamento em blocos de concreto armado com dimensões 350 x 200 x 900 mm. Os tipos de ancoragem testados foram divididos em cinco grupos, contendo ancoragens com ganchos com 45°, ganchos com 180°, dobras com 90°, conectores com cabeça e barras retas com complementação de barras transversais complementares soldadas. O comprimento de embutimento variou em uma série com 60 mm e outro com 110 mm, sendo a primeira executada com barras de diâmetro nominal igual a10 mm e a segunda, barras com 16 mm. Os resultados obtidos com os ensaios possibilitaram avaliar comparativamente o comportamento dos modelos quanto às deformações nas armaduras de flexão e na barra ancorada, deslocamentos relativos da ancoragem, cargas últimas, modos de ruptura e geometrias de ruptura. Foi feita uma análise geral da influência do tipo de terminação mecânica da ancoragem na determinação da capacidade resistente quando submetidas à tração e com o modo de ruptura do concreto, e ainda foram realizadas análises dos modelos teóricos de estimativa de resistência das seguintes recomendações: ACI 318 (2014), fib Bulletin 58 (2011), EOTA /ETAG Nº 001 – Anexo C (1997); Regan (2000) e Sperry et. al (2017). Foi possível observar que a ruptura com geometria cônica determinada para conectores com cabeça, acontecem com ancoragens com ganchos com 45° e 180°, dobras com 90° e barras retas com barras transversais complementares. A avaliação dos diferentes tipos de ancoragem, comprovou que esse parâmetro poderia ser levado em consideração na determinação da capacidade última resistente, assim como definido por Regan (2000). O modelo teórico que teve o melhor desempenho para os modelos avaliados foi o de Regan (2000). / This research was conducted to analyze the performance of different anchors pre-installed in reinforced concrete and subjected to tensile loading. For this, 34 pullout tests were performed on reinforced concrete blocks with dimensions 350 x 200 x 900 mm. The types of anchors tested were divided into five groups, containing anchors with hooks with 45 °, hooks with 180 °, bends with 90 °, headed studs and straight bars with complementation of complementary cross bars welded. The embedment lengths varied in a series with 60 mm and the other one with 110 mm, the first one executed with bars of nominal diameter equal to 10 mm and the second one, bars with 16 mm. The results obtained with the tests allowed evaluating comparatively the behavior of the models for the deformations in the flexural reinforcement and in the anchored bar, relative displacements of the anchorage, ultimate loads, failure modes and the failure plane geometries. A general analysis of the influence of the k coefficient on the determination of the capacity of anchors subjected to tensile loading and with the failure mode of the concrete breakout, was made the analyzes of theoretical models of resistance estimation of the following recommendations were also performed: ACI 318 (2014), fib Bulletin 58 (2011), EOTA / ETAG No. 001 - Annex C (1997); Regan (2000) and Sperry et. al (2017). It was possible to observe that the failure with conical geometry determined for connectors with head, happen with anchors with hooks with 45 ° and 180 °, bends with 90 ° and straight bars with complementary cross bars. The evaluation of the different types of anchorage proved that this parameter could be considered in determining the ultimate resistant capacity, as defined by Regan (2000). The theoretical model that had the best performance for the models evaluated was that of Regan (2000).
36

Análise de pavimentos de edifícios utilizando a analogia de grelha

Reis, Eduardo Martins dos January 2007 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-graduação em Engenharia Civil / Made available in DSpace on 2012-10-23T07:10:48Z (GMT). No. of bitstreams: 1 244863.pdf: 3442980 bytes, checksum: 6175829578d1f8940cdf7645703a9863 (MD5) / No procedimento manual empregado para determinação dos esforços e deformações nos pavimentos de edifícios em concreto armado, adota-se a decomposição da estrutura em lajes e vigas para a análise individual de cada elemento. Neste trabalho, será realizado um estudo sobre avaliação de esforços de pavimentos utilizando a técnica da analogia de grelha, considerando-se a interação lajeviga-pilar, num comparativo com outros processos, como o método dos elementos finitos e métodos simplificados. Ainda sim, será necessário avaliar alguns parâmetros que podem modificar os resultados na modelagem de um painel de lajes, sendo desta forma, importante analisar o efeito de cada um deles separadamente, entre eles, a rigidez à torção da viga e a influência da disposição da malha sobre o pavimento. In the manual process employed for the determination of the efforts and deformations in the pavements of concrete buildings, the decomposition of the structure is adopted in slab and beams for the individual analysis of each element. In this work, will be made a study about evaluation of the pavement bending moments using the technique of the grid analogy, being considered the interaction slabbeam-column, in a comparative one with other processes, as the method of the finite elements and simplified methods. Finally, it will be necessary to evaluate some parameters that can modify the results in the modelling of a panel of slabs, being this way, important to analyze the effect separately of each one of them, among them, the torsion to rigidity of the beam and the influence of the disposition of the mesh on the pavement.
37

Análise de alternativas de projeto para pavimentos sem vigas em concreto armado

Dal Prá, Artur Antonio January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Civil, Florianópolis, 2012 / Made available in DSpace on 2013-06-25T20:31:59Z (GMT). No. of bitstreams: 1 313677.pdf: 4959228 bytes, checksum: 82cc017309057d2ebf700ff5ffd05ac3 (MD5) / Há diversas alternativas estruturais para pavimentos em concreto armado de edificações, podendo ser empregados sistemas sem vigas (lajes lisas, nervuradas e maciças), sistemas convencionais (de lajes, vigas e pilares), ou até mesmo combinar ambos os sistemas, aproveitando as vantagens específicas de cada um deles conforme os fins a que se destinam. Cada uma destas opções tem seu uso direcionado às características geométricas de cada projeto. Ou seja, os vãos a ser vencidos e as diversas possibilidades de posicionamento dos pilares. O mercado imobiliário mostra-se competitivo, então é apropriado combinar qualidade, baixo custo e rapidez. Dependendo das características da obra, justifica-se privilegiar algum determinado aspecto dentre os demais. Este trabalho se propõe a avaliar, de maneira comparativa, algumas soluções para estruturas de pavimentos sem vigas, nas diferentes alternativas construtivas: lajes maciças sem vigas (com e sem armadura para evitar a punção), laje lisa nervurada com cubetas e alternativa para pavimento convencional de laje-vigapilar. Para fazer tal estudo, definem-se dois diferentes projetos, onde ocorre o dimensionamento das alternativas citadas e obtenção dos índices de consumo para direcionar anteprojetos e estimar viabilidade de alternativas. Conclui-se que não é adequado afirmar que determinada alternativa é sempre mais viável em detrimento de outra, pois cada caso tem suas particularidades e a análise de viabilidade deve compreender as consequências impostas por cada alternativa, como a influência do Estado Limite de Serviço e os aspectos arquitetônicos.<br> / Abstract : There are several alternatives for structural concrete floors of buildings, can be employed without beams systems (flat slabs, ribbed and solid , conventional systems (slabs, beams and columns), or even combine both systems, taking the specific advantages of each of them according to their intended purposes. Each of these options has its use targeted to geometric characteristics of each project. That is, the gaps to be overcome and the various possibilities for positioning of the collumns. The real estate market seems to be competitive, then it is appropriate to combine quality, low cost and speed. Depending on the characteristics of the work is justified to focus a preference among the others. This study aims to assess in a comparative way some solutions to structural floors without beams in different constructive alternatives: solid slabs without beams (with and without reinforcement to avoid punch), ribbed slab with buckets and alternative to conventional floor slab-beam-column. To make such study were defined two different projects, which were calculated the alternatives mentioned and provided parameters for direct projects and estimate the feasibility of alternatives. Conclude that it isn#t appropriate to say that a particular alternative is always more viable over another, because each case has its own peculiarities and feasibility analysis should consider the consequences imposed by each alternative, as the influence of the Service State and architectural aspects.
38

Punção em lajes cogumelo de concreto armado com capitéis / Punching strength of reinforced concrete mushroom slabs with column capitals

Lima Neto, Aarão Ferreira 29 June 2012 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2012. / Submitted by Alaíde Gonçalves dos Santos (alaide@unb.br) on 2013-03-12T11:02:40Z No. of bitstreams: 1 2012_AaraoFerreiraLimaNeto.pdf: 13715701 bytes, checksum: 0ac40e8cad702a927575a133d4dde7ed (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2013-03-13T11:36:48Z (GMT) No. of bitstreams: 1 2012_AaraoFerreiraLimaNeto.pdf: 13715701 bytes, checksum: 0ac40e8cad702a927575a133d4dde7ed (MD5) / Made available in DSpace on 2013-03-13T11:36:48Z (GMT). No. of bitstreams: 1 2012_AaraoFerreiraLimaNeto.pdf: 13715701 bytes, checksum: 0ac40e8cad702a927575a133d4dde7ed (MD5) / O capitel é um elemento estrutural usado para facilitar a transferência das cargas nas lajes para os pilares em pavimentos sem vigas. Eles são bastante utilizados no combate à punção, apesar de até hoje existirem poucos estudos desenvolvidos com o objetivo de avaliar sua eficiência e a influência das diversas variáveis de projeto no comportamento e resistência de ligações laje-pilar com capitéis. Este trabalho tem como objetivo contribuir para o entendimento do comportamento de lajes cogumelo, avaliando ainda as recomendações apresentadas pelas normas de projeto. Foram analisadas experimentalmente 12 lajes de concreto armado sob carregamento simétrico, sendo destas 2 lajes lisas, usadas como referência, e 10 lajes cogumelo, com variação da seção transversal dos pilares, assim como na seção transversal e inclinação dos capitéis. Foram utilizados nas lajes concreto com resistência à compressão variando de 32 a 46 MPa, não sendo utilizadas armaduras de cisalhamento. E com as armaduras de flexão distribuídas ortogonalmente. As lajes eram quadradas com lado de 2600 mm e espessura de 140 mm, com segmentos de pilares de seção quadrada, retangular e circular. As principais variáveis foram as seções transversais dos capitéis, modificadas de acordo com a seção do pilar, suas inclinações, que variaram na razão de 1:1,5, 1:2, 1:3 e 1:4 e sua espessura que foi de 110 mm para a primeira inclinação e de 55 mm para as demais. São apresentados e analisados resultados de cargas últimas e modos de ruptura, padrões de fissuração, flechas, deformações do concreto e da armadura de flexão principal. São também apresentadas comparações entre as cargas de ruptura observadas e estimadas de acordo com as recomendações das normas NBR 6118 (2007) e EUROCODE2 (2004), assim como as estimativas pela Teoria da Fissura Crítica de Cisalhamento, desenvolvida por MUTTONI (2008). Por fim, as lajes foram analisadas através de modelos computacionais não-lineares axissimétricos, empregando um software que utiliza o método dos elementos finitos (MEF), objetivando compreender melhor o mecanismo de ruptura por punção de lajes com capitel. Os resultados mostraram a eficiência dos capitéis no aumento da capacidade resistente, com ganhos de até 80% em relação às lajes sem capitéis, assim como maior ductilidade nos modos de ruptura. Foi possível comprovar a previsão da localização da superfície de ruptura para lajes apoiadas em capitéis com inclinações de até 1:2. _______________________________________________________________________________________ ABSTRACT / The capital is a structural element used to facilitate the transfer of loads on the slab for the columns on floors without beams. They are widely used to combat punching, although to date there are few studies with the aim of evaluating its effectiveness and influence of various design variables on the behavior and strength of slab-column connections with capitals. This paper aims to contribute to the understanding of the behavior of mushroom slabs, still assessing the recommendations made by the design standards. Twelve (12) reinforced concrete slabs under symmetrical loading were experimentally analyzed, with 2 flat slabs for reference, and 10 mushroom slabs with variations in the cross section of the columns and capitals and its inclination as well. Concrete with compressive strength ranging from 32 to 46 MPa was used, all of them without shear reinforcement and with the same two-way flexural reinforcement. The slabs were square with sides measuring 2600 mm and thickness of 140 mm, with short length columns with square, rectangular or circular cross sections. The main variables were the cross sections of the capitals, which varied according to the columns cross section shapes, and their inclinations of 1:1.5, 1:2, 1:3 and 1:4. Results for failure loads and modes, crack patterns, deflections, concrete and steel strains are presented and analyzed. Comparisons between experimental and estimated failure loads according to the codes NBR 6118 (2007) and EUROCODE2 (2004) are presented and discussed, including estimates given by the Critical Shear Crack Theory developed by MUTTONI (2008). Finally, the slabs were analyzed through non-linear axisymmetric computational models, using a finite element software, in order to better understand the punching failure mechanism of mushroom slabs with capitals. The results showed the efficiency of the capital to increase the punching resistance of the slabs, with gains of up to 80% compared to the slabs without capitals, and more ductility for the failure modes as well. It was also possible to prove the prediction for the failure surface position in slabs supported by capital with inclinations of up to 1:2.
39

Punção em lajes lisas com armadura de cisalhamento submetidas a carregamento excêntrico e apoiadas sobre pilares retangulares

Oliveira, Marcos Honorato de 03 1900 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2013. / Submitted by Alaíde Gonçalves dos Santos (alaide@unb.br) on 2013-07-19T14:54:30Z No. of bitstreams: 1 2013_MarcosHonoratodeOliveira.pdf: 38148080 bytes, checksum: 5660b8bb69e2078dc6186be5ea890f0a (MD5) / Approved for entry into archive by Leandro Silva Borges(leandroborges@bce.unb.br) on 2013-07-19T17:30:34Z (GMT) No. of bitstreams: 1 2013_MarcosHonoratodeOliveira.pdf: 38148080 bytes, checksum: 5660b8bb69e2078dc6186be5ea890f0a (MD5) / Made available in DSpace on 2013-07-19T17:30:34Z (GMT). No. of bitstreams: 1 2013_MarcosHonoratodeOliveira.pdf: 38148080 bytes, checksum: 5660b8bb69e2078dc6186be5ea890f0a (MD5) / O fenômeno de punção em lajes lisas é um fator determinante na elaboração e nas verificações de projeto deste tipo de sistema construtivo. Quando a ligação laje-pilar está submetida a carregamento excêntrico o número de variáveis envolvidas na formulação é consideravelmente maior em relação à situação de carregamento simétrico, o que aparentemente reduz a precisão do método de verificação para este caso. O emprego da armadura de cisalhamento é uma solução bastante utilizada para aumentar a resistência à punção da ligação laje-pilar. É com base nestas informações que este trabalho propõe um estudo de lajes lisas com e sem utilização de armadura de cisalhamento submetidas a carregamento simétrico ou excêntrico. Foram analisadas experimentalmente dezesseis modelos locais de laje lisa apoiada sobre um pilar retangular interno. As lajes foram armadas ao cisalhamento com armadura do tipo double-headed stud e submetidas a carregamento simétrico e excêntrico. As lajes possuíam dimensões quadradas com 2500 mm de lado e 180 mm de espessura, moldadas com concreto usinado de resistência média em torno de 50 MPa. O pilar de cada modelo possuía seção transversal com dimensões retangulares de 200mm por 400mm. As principais variáveis de ensaio foram a utilização ou não de armadura de cisalhamento, a taxa de armadura de cisalhamento, o número de camadas da armadura de cisalhamento, o tipo de carregamento (simétrico ou excêntrico) e o eixo de flexão dos modelos submetidos ao carregamento excêntrico. São apresentados os resultados de carga última, dos deslocamentos verticais, das deformações na armadura de flexão, das deformações na armadura de cisalhamento, das deformações no concreto e também a posição e inclinação da superfície de ruptura das lajes e o mapa de fissuração de cada laje. Os resultados experimentais coletados foram adicionados a um banco de dados criado para uma análise de desempenho das recomendações sobre a verificação da resistência à punção de algumas normas de projeto. As normas analisadas foram: NBR 6118 (2007), Eurocode 2 (2004), ACI 318M (2008) e também foram avaliadas as prescrições utilizadas para as estimativas de resistência à punção da Teoria da Fissura Crítica de Cisalhamento (TFCC). Algumas das principais contribuições deste trabalho foram a adaptação do Método da Superfície de Resistência Mínima (MSRM) para o caso de lajes submetidas a carregamento simétrico e a proposta de uma nova formulação para este método no caso de lajes submetidas a carregamento excêntrico. _______________________________________________________________________________________ ABSTRACT / The punching shear phenomenon in flat slabs is a main factor in the design of this type of structural system. When the slab-column connection is subjected to eccentric loading the number of involved variables in the formulation is considerably higher if compared to the situation of symmetrical loading, which apparently reduces the accuracy of the verification method for this case. The use of shear reinforcement is a solution often used to increase the punching shear strength in the slab-column connection. It is based on these information that this work proposes a study of the use of flat slabs with shear reinforcement and subjected to symmetrical and eccentric loading. Sixteen local models of flat slab supported on a rectangular internal column were tested. The slabs had shear reinforcement consisting of double-headed studs and were subjected to symmetrical and eccentric loading. The slabs had square dimensions with a side of 2,500 mm and with a thickness of 180 mm, casted concrete with average compressive strength around 50MPa. The column of each model had rectangular dimensions: 200 mm wide by 400 mm long. The principal test’s variables were the use of shear reinforcement, the rate of shear reinforcement, the number of layers of shear reinforcement, the type of load (symmetrical or eccentric) and the bending axis in the case of to eccentric loading . The results consist of vertical displacements of the slabs, strains in the bending and shear reinforcement, strains on the concrete and also the position and inclination of the failure surface of the slabs and cracking map of each slab. The experimental results collected were added to a database created for a comparative analysis of design code recommendations on punching shear strength. The codes analyzed were: NBR 6118 (2007), Eurocode 2 (2004), ACI 318M (2008) .The procedure used to estimate the ultimate punching shear strength of the Critical Shear Crack Theory (CSCT) was also evaluated. Some of the main contributions of this work were an adaptation of Surface of Minimum Shear Resistance (SMSR) for the case of slabs subjected to symmetrical loading and a new formulation for this method in the case of slabs subjected to eccentric loading.
40

Avaliação do comportamento eletroquímico de sistemas de reparo para estruturas de concreto com corrosão de armaduras. / Evaluation of electrochemical behavior of repair systems for concrete structures with reinforcement corrosion.

Maurício Luiz Grochoski Garcia 14 April 2008 (has links)
A cada dia os custos econômicos e sociais da corrosão de armaduras nas estruturas de concreto armado têm se tornado mais significativos nas economias dos países, tanto desenvolvidos, quanto em desenvolvimento. Em 2004, a Alemanha gastou aproximadamente 90 bilhões de euros com manutenção e reparo de estruturas de concreto armado, o correspondente a 50% do total gasto na construção civil deste país. Essa parcela é ainda maior no caso da Itália, onde chega a 57% (UEDA & TAKEWAKA, 2007). Esses gastos mostram o crescimento do mercado mundial de reparo e proteção de estruturas de concreto. Esse mercado já conta com várias soluções disponíveis e a cada dia novos produtos surgem, e outros tantos estão em estudo, seja para a prevenção ou para terapia da corrosão. Diante dessa gama de produtos e sistemas para prevenção e reparo, os engenheiros responsáveis por prescrevê-los para as obras de recuperação, reforço e proteção, precisam conhecer adequadamente o seu comportamento e sua real eficácia, ou seja, precisam dispor de metodologias para bem avaliar a viabilidade técnica e econômica dos sistemas e dos produtos disponíveis. O estudo desenvolvido durante esta tese procurou, de forma bastante abrangente, avaliar o comportamento eletroquímico, em campo e em laboratório, de seis diferentes sistemas de reparo para estruturas de concreto com corrosão de armaduras, com características bastante distintas. Em campo foi proposto e aplicado um método deavaliação e comparação destes sistemas, utilizando como parâmetros o potencial e a intensidade de corrosão. Em laboratório, além destes parâmetros eletroquímicos, outros parâmetros físicos e mecânicos também foram avaliados. ) Os resultados obtidos em campo mostraram tendências de comportamento bastante interessantes dos sistemas de reparo avaliados, que, apesar do prazo curto para a realização do experimento (2 anos), permitiram extrair algumas informações importantes acerca do comportamento destes na situação real de uso. Além disso, esta pesquisa mostrou que o método de avaliação aqui proposto é bastante promissor. Os resultados de laboratório, além de contribuir para o entendimento do comportamento dos diferentes sistemas, mostraram a complexidade da avaliação dos sistemas de reparo e a necessidade de consideração das variáveis importantes no problema. / Social and economic costs due to reinforcement corrosion are becoming even more significant all over the world, in developed countries and also in under development ones. In 2004, Germany has spent approximately 90 billion euros with maintenance and repair of concrete structures, what corresponds to 50% of all money spent on Germany\'s civil construction sector. In Italy, this percentage is even greater, reaching 57% (UEDA & TAKEWAKA, 2007). These facts show an increase in the world market of maintenance and repair of concrete structures. There are already many maintenance and repair solutions available and there are more solutions being released every day. Due to this great diversity of solutions, the engineer responsible for recommending their use, must know properly their behavior and real efficiency. This study aimed to evaluate the electrochemical behavior of six different repair systems for concrete with reinforcement corrosion, on-site and in the laboratory. On site an evaluation and comparison method based on corrosion potential and intensity was proposed and applied. In the laboratory, besides these parameters, physical and mechanical ones were also evaluated. Despite the experiment\'s short duration (2 years), the on-site results showed interesting behavior trends for the evaluated systems, allowing some important information about them to be extracted. Nevertheless, the proposed method has showed itself to be very promising. The results obtained in thelaboratory have made great contribution on understanding the systems repair\'s behaviors. Furthermore they showed the complexity of this theme and the necessity of consideration of all playing variables.

Page generated in 0.0462 seconds