Spelling suggestions: "subject:"one team"" "subject:"one beam""
51 |
Evaluating the potential for cone beam CT to improve the suspected scaphoid fracture pathway: InSPECTED - A single-centre feasibility studySnaith, Beverly, Harris, M., Hughes, J., Spencer, N., Shinkins, B., Tachibana, A., Bessant, G., Robertshaw, S. 01 April 2022 (has links)
Yes / The suspected scaphoid fracture remains a diagnostic conundrum with over-treatment a common risk-averse strategy. Cross-sectional imaging remains the gold standard with MRI recommended but CT used by some because of easier access or limited MRI availability. The aim of this feasibility study was to evaluate whether cone beam computed tomography (CBCT) could support early diagnosis, or exclusion, of scaphoid fractures.
Patients with a suspected scaphoid were recruited fracture between March and July 2020. All underwent a 4-view X-ray. If this examination was normal, they were immediately referred for a CBCT scan of the wrist. Those with a normal scan were discharged to research follow-up at 2 and 6-weeks.
68 participants were recruited, 55 had a normal or equivocal X-ray and underwent CBCT. Nine additional radiocarpal fractures (16.2%) were demonstrated on CBCT, the remainder were discharged to research follow-up. Based on the 2-week and 6-week follow up three patients (4.4%) were referred for MRI to investigate persistent symptoms with no bony injuries identified.
CBCT scans enabled a rapid pathway for the diagnosis or exclusion of scaphoid fractures, identifying other fractures and facilitating early treatment. The rapid pathway also enabled those with no bony injury to start rehabilitation, suggesting that patients can be safely discharged with safety-net advice following a CBCT scan.
|
52 |
Avaliação da tomografia computadorizada Cone Beam como método de proservação de lesões periapicais após o tratamento endodôntico em pacientes com fissura labiopalatina / Evaluation of cone beam computed tomography as a method of follow-up of periapical lesions after endodontic treatment in patient with cleft lip and palateDextre, Tulio Lorenzo Olano 29 June 2012 (has links)
O objetivo deste trabalho foi comparar a eficácia da Tomografia Computadorizada Cone Beam e a Radiografia Periapical como métodos de proservação de lesões periapicais após o tratamento endodôntico. Foram avaliadas no estudo Radiografias e Tomografias de 1.462 indivíduos com fissura labiopalatina no Hospital de Reabilitação de Anomalias Craniofaciais Universidade de São Paulo, que compareceram para o tratamento endodôntico entre os anos 2009 e 2011. De acordo com os critérios de inclusão, foram selecionados 46 dentes unirradiculares com lesão periapical, os quais foram divididos nos grupos: avaliação Radiográfica (Grupo I) e avaliação Tomográfica (Grupo II). Os dados foram analisados por meio do escore PAI para as alterações periapicais encontradas. Nos resultados observou-se que houve diferença estatisticamente significativa nos grupos estudados. Em 34 casos os escores atribuídos às Tomografias dos dentes avaliados foram maiores do que os escores atribuídos às Radiografias Periapicais dos mesmos dentes avaliados, comprovando a maior precisão da Tomografia Computadorizada Cone Beam. Desta forma, a análise dos resultados obtidos neste trabalho permite constatar que a Tomografia Computadorizada Cone Beam é mais eficaz na proservação de lesões periapicais do que a Radiografia Periapical após o tratamento endodôntico em pacientes com fissura labiopalatina. / The aim of this study was to compare the effectiveness of Cone Beam Computed Tomography and periapical radiography as a follow-up method of periapical lesions after endodontic treatment. We evaluated in the study radiographs and tomography scans of 1,462 individuals with cleft lip and palate at the Hospital of Rehabilitation of Craniofacial Anomalies - University of Sao Paulo who came for treatment endodontic between the years 2009 and 2011. According to inclusion criteria were selected 46 single-rooted teeth with periapical lesions, which were divided into groups radiographic evaluation (Group I) and tomographic evaluation (Group II). Data were analyzed using the PAI score for periapical changes found. The results were observed that statistically significant differences in the groups studied. In 34 cases the CT scores attributed to the teeth evaluated were higher than the scores attributed to the radiographs of same teeth evaluated, demonstrating the greater precision of Cone Beam Computed Tomography. Thus, analysis of results obtained in this work demonstrates that the Cone Beam Computed Tomography is more effective in follow-up of periapical lesions than periapical radiography after endodontic treatment in patients with cleft lip and palate.
|
53 |
Avaliação dos componentes anatômicos do sistema estomatognático de crianças com bruxismo, por meio de imagens obtidas por tomografia computadorizada cone beam / Evaluation of the anatomical structures of the stomatognathic system in children with bruxism by cone beam computed tomographySabbatini, Iliana Ferraz 09 January 2012 (has links)
Dentre as atividades parafuncionais do sistema estomatognático, pode-se salientar o bruxismo, o qual pode se manifestar tanto durante o sono (BS), quanto durante o dia (Bruxismo Diurno BD) ocorrendo em distintos estados de consciência (sono e vigília). A Classificação Internacional dos Distúrbios do Sono define o bruxismo como “um distúrbio com movimentos de padrão desordenado do sistema mastigatório que envolve o ranger ou apertar dos dentes durante o sono”. O diagnóstico de bruxismo é realizado clinicamente, com base no relato de uma história prévia recente de sons de ranger de dentes que ocorreram pelo menos de 3 a 5 noites por semana, durante 6 meses. A presença de facetas de desgaste dental, manifestações de dor matinal nos músculos mastigatórios, a hipertrofia do músculo masseter, a hipersensibilidade ou estalo da Articulação Temporomandibular (ATM), impressões dentais na bochecha ou língua e mobilidade dental, entre outros, são sinais característicos desta parafunção. Não obstante, frente à crescente valorização do aspecto funcional, a avaliação não deve se restringir apenas ao exame clínico. Nesse sentido, a imaginologia vem se tornando um recurso de valor inestimável para a determinação de um diagnóstico. Assim, o objetivo do presente trabalho é descrever as possíveis alterações dos componentes anatômicos da articulação temporomandibular (ATM), de crianças com bruxismo, por meio da análise de imagens obtidas pela técnica de Tomografia Computadorizada Cone Beam. Com base nos critérios de inclusão e exclusão, foram selecionados 20 indivíduos, entre 7 e 11 anos de idade, do sexo masculino e feminino, em atendimento na Clínica Infantil da FORP USP. Na avaliação clínica para diagnóstico de bruxismo, foi evidenciado a presença de todas, ou algumas das seguintes alterações: presença de facetas de desgaste dental, fraturas de restaurações, fraturas dentais, impressões dentais em bochechas e língua, dor na ATM, ruído na ATM, dor nos músculos masseter e temporal. O exame tomográfico foi realizado em um aparelho de tomografia i-CAT e durante as reconstruções multiplanares, antes de gerar as imagens, o volume total do paciente foi transferido para o scanner com a utilização do plano de Frankfurt paralelo ao solo. Na análise de variáveis categóricas, utilizou-se teste Exato de Fisher e teste de Fisher com a extensão de Freeman-Halton. Foi considerado estatisticamente significante valor de p ≤ 0,05. Em algum grau, todos os pacientes relataram dor à palpação dos músculos temporal e masseter, assim como à palpação da ATM. A presença de alterações na ATM somente apresentou significância estatística na presença de osteófitos na região articular do lado direito em associação com dor na articulação temporomandibular ipsilateral (p=0,04). Erosões e esclerose não foram encontradas em nenhum paciente e aplainamento foi um achado na totalidade dos indivíduos, porém, não apresentando relação estatísticamente significante quando cruzado com achados clínicos. A presença de dor no músculo temporal e a relação horizontal côndilo-fossa contralateral, apresentaram significância estatística (p<0,05). No músculo masseter essa associação apresentou significância estatística com a relação horizontal côndilo-fossa ipsilateral (p=0,01). Os achados sugerem que o bruxismo pode promover alterações significativas nas estruturas do sistema estomatognático desde a infância. / Among the parafunctional activities of masticatory system, bruxism can be higlighted. It occurs during sleep (Sleep Bruxism - SB) or wakefulness (Awake Bruxism - DB), which occur in two different states of consciousness (sleep and wakefulness). The International Classification of Sleep Disorders defines bruxism as \"a movement disorder with a stereotyped pattern of the masticatory system that involves teeth grinding or clenching during sleep.\" Bruxism is clinically diagnosed based on reports of teeth grinding noises that occurred at least three to five nights per week for 6 months. Also, the presence of wear facets, matutinal pain in the masticatory muscles, masseter muscle hypertrophy, temporomandibular joint (TMJ) noise or hypersensitivity, dental impressions on the cheek or tongue and tooth mobility, among others, are hallmarks of this parafunction. However, the evaluation should not be restricted to clinical examination since functional aspects are gaining importance. As consequence, imaging has become an invaluable resource for diagnosis. The objective of this paper is to describe possible changes in temporomandibular joint (TMJ) anatomical components in children with bruxism by Cone Beam Computed Tomography image analysis. Based on the inclusion and exclusion criteria, Twenty 7-11-years old male and female children treated at Ribeirão Preto Pediatric Dentistry Clinic, University of São Paulo, Brazil, were selected. The presence of all or some of the following changes was used in clinical evaluation for bruxism diagnosis in the present study: presence of wear facets, fractures in fillings, dental fractures, dental impressions in cheek and tongue, TMJ pain and clicking, masseter and temporalis muscles pain. The CT scan was performed on a i-CAT CT device and during multiplanar reconstructions, before obtaining image, the total volume of the patient was transferred to the scanner using the Frankfurt plane parallel to the ground. In Statistical analysis Fisher\'s exact test and Fisher\'s test with the Freeman-Halton extension were used for categorical variables. Values of p ≤ 0.05 were considered statistically significant. In the results, all patients reported pain on palpation of the temporalis and masseter muscles, as well as TMJ palpation. Erosions and sclerosis were not found. Flattening was present in all individuals, however, no statistical significance was found between this feature and clinical findings. The presence of osteophytes in the TMJ was associated with ipsilateral pain in temporomandibular joint palpation (p = 0.04). There was an association between pain in the contralateral temporal muscle and the condyle-fossa relationship in the horizontal direction (p <0.05). There was also a correlation between pain in the ipsilateral masseter muscle and the condyle-fossa relationship in the horizontal direction (p = 0.01). In conclusion, our findings suggest that bruxism can promote significant changes in the structures of the stomatognathic system since childhood.
|
54 |
Avaliação qualitativa de biomateriais utilizados para enxertia em alvéolos dentais, em mandíbulas de suínos, por meio da tomografia computadorizada Cone Beam / Qualitative evaluation of biomaterials used in pig mandibles dental cavities graftings, by means of Cone-Beam computed tomographyAzevedo, Ana Cláudia 17 June 2013 (has links)
A invenção da Tomografia Computadorizada revolucionou o método de diagnóstico. Apesar de ser um exame de custo elevado, sua confiabilidade é de grande valia. Na década de noventa foram descritos os primeiros relatos da tomografia computadorizada Cone Beam para o uso na Odontologia. Esses aparelhos de tomografia computadorizada por feixe cônico, Cone Beam ou volumétrica são mais compactos, de menor custo e com menor tempo de exposição à radiação ao paciente, quando comparados aos aparelhos de tomografia computadorizada médica ou Fan Beam. Diante da grande utilização de implantes osseointegrados, algumas dificuldades foram despontando, visto que também paralelamente a este, os defeitos ósseos necessitavam de correção. Então os enxertos ósseos ou biomateriais de enxertia passaram a ser a alternativa que possibilitava a correção dessas perdas ósseas. Com o objetivo de estudar e avaliar qualitativamente os biomateriais de enxertia, inseridos em alvéolos dentais, em mandíbulas de suínos, por meio da tomografia computadorizada Cone Beam, utilizou-se de 20 mandíbulas dissecadas de porco, dos quais foram extraídos quatro dentes e nesses alvéolos foram introduzidos quatro biomateriais de enxertia de composições diferentes, com propriedades físico-químicas distintas, forma física, origem e de classificações diferentes. As mandíbulas de suínos foram submetidas a um exame de tomografia computadorizada volumétrica. As imagens obtidas foram avaliadas por um Software específico. Os resultados mostraram que não existiu diferença entre os cortes C (corte coronal) e S (corte sagital) e entre os cortes SS (corte parassagital) e o corte PAN (corte panorâmico), sendo que os corte C e S tiveram maior observação e os cortes SS e PAN, foram os de menor observação. Quanto ao material M-C (GenPhos HA TCP®, G 50, 0.5cc) foi o que obteve maior média de observação (com média 1, 81) enquanto que o M-B (OrthoGen®, G 75, 0.5cc) foi o mais difícil de ser observado, nos contes C (corte coronal) e S (corte sagital). Em relação a homogeneidade os materiais M-B (OrthoGen®, G 75, 0.5cc) e M-D (GenOx Inorg Esponjoso®) não apresentaram diferenças significativas, sendo portanto os materiais considerados menos homegêneos, quando se referem a densidade; observados nos cortes C (corte coronal) e S (corte sagital). Já os materiais M-C (GenPhos HA TCP®, G 50, 0.5cc) e M-A (Biogran® 300-350m, 50-45 mesh) segundo os p-valores não foram considerados estatisticamente diferentes, portanto os materiais que apresentaram as imagens mais homogêneas, igualmente aos demais materiais, foram observados nos cortes C (corte coronal) e S (corte sagital). O corte PAN (corte panorâmico) com média 1,43, foi a imagem que permitiu uma melhor observação dos biomateriais de enxertia. Todos os avaliadores afirmaram que identificaram o alvéolo ou o biomaterial de enxertia considerando a referência anatômica (lâmina dura). / The invention of Computed Tomography has radically changed the method of diagnosis. Even though it is a high-cost exam, its reliability is really worth it. The first reports about the use of Cone-Beam Computed Tomography in Dentistry were described during the 1990s. These conic bundle, Cone-Beam or volumetric computed tomography devices are more compact, less expensive and provide the lowest radiation dose for the patient when compared to other medical or Fan-Beam computed tomography devices. Once there has been a wide use of osseointegrated implants, some difficulties have emerged as, in parallel to this, there were some bone defects that required correction. Therefore, bone graftings or biomaterials for graftings have become an alternative that allowed correcting bone losses. With the objective to study and evaluate qualitatively the grafting biomaterial inserted pig mandibles dental cavities by Cone-Beam computed tomography, it was used 20 dissected pig mandibles, from which four teeth have been extracted and four biomaterial graftings of different compositions, different physical-chemical properties, physical shape, origin and classifications have been inserted into those cavities. The pig mandibles were submitted to a volumetric computed tomography. Images were evaluated by specific software. Results showed that there was no difference between C (coronal section) and S (sagittal section) sections, and between SS (parassagittal section) and PAN (panoramic section) sections. C and S sections had more observation and SS and PAN sections were the ones with less observation. Concerning the material, M-C (GenPhos HA TCP®, G 50, 0.5cc) was the one that obtained the highest observation average (1,81) while M-B (OrthoGen®, G 75, 0.5cc) was the most difficult to be observed on C (coronal) and S (sagittal) sections. About the homogeneity of materials, M-B (OrthoGen®, G 75, 0.5cc) and M-D (GenOx Inorg Esponjoso®) did not show significant differences, being, therefore, the materials considered the least homogeneous regarding density; observed in C (coronal) and S (sagittal) sections. According to p-values, materials M-C (GenPhos HA TCP®, G 50, 0.5cc) and M-A (Biogran® 300-350m, 50-45 mesh) were not considered statistically different. Thus the materials that presented the most homogeneous images, as well as the other materials, were observed in C (coronal) and S (sagittal) sections. The PAN (panoramic) section, with an average of 1,43, was the image that allowed the best observation of the grafting biomaterials. All evaluators affirmed to have identified the cavity of the grafting biomaterial considering the anatomic reference (hard slide).
|
55 |
Avaliação dos componentes anatômicos do sistema estomatognático de crianças com bruxismo, por meio de imagens obtidas por tomografia computadorizada cone beam / Evaluation of the anatomical structures of the stomatognathic system in children with bruxism by cone beam computed tomographyIliana Ferraz Sabbatini 09 January 2012 (has links)
Dentre as atividades parafuncionais do sistema estomatognático, pode-se salientar o bruxismo, o qual pode se manifestar tanto durante o sono (BS), quanto durante o dia (Bruxismo Diurno BD) ocorrendo em distintos estados de consciência (sono e vigília). A Classificação Internacional dos Distúrbios do Sono define o bruxismo como “um distúrbio com movimentos de padrão desordenado do sistema mastigatório que envolve o ranger ou apertar dos dentes durante o sono”. O diagnóstico de bruxismo é realizado clinicamente, com base no relato de uma história prévia recente de sons de ranger de dentes que ocorreram pelo menos de 3 a 5 noites por semana, durante 6 meses. A presença de facetas de desgaste dental, manifestações de dor matinal nos músculos mastigatórios, a hipertrofia do músculo masseter, a hipersensibilidade ou estalo da Articulação Temporomandibular (ATM), impressões dentais na bochecha ou língua e mobilidade dental, entre outros, são sinais característicos desta parafunção. Não obstante, frente à crescente valorização do aspecto funcional, a avaliação não deve se restringir apenas ao exame clínico. Nesse sentido, a imaginologia vem se tornando um recurso de valor inestimável para a determinação de um diagnóstico. Assim, o objetivo do presente trabalho é descrever as possíveis alterações dos componentes anatômicos da articulação temporomandibular (ATM), de crianças com bruxismo, por meio da análise de imagens obtidas pela técnica de Tomografia Computadorizada Cone Beam. Com base nos critérios de inclusão e exclusão, foram selecionados 20 indivíduos, entre 7 e 11 anos de idade, do sexo masculino e feminino, em atendimento na Clínica Infantil da FORP USP. Na avaliação clínica para diagnóstico de bruxismo, foi evidenciado a presença de todas, ou algumas das seguintes alterações: presença de facetas de desgaste dental, fraturas de restaurações, fraturas dentais, impressões dentais em bochechas e língua, dor na ATM, ruído na ATM, dor nos músculos masseter e temporal. O exame tomográfico foi realizado em um aparelho de tomografia i-CAT e durante as reconstruções multiplanares, antes de gerar as imagens, o volume total do paciente foi transferido para o scanner com a utilização do plano de Frankfurt paralelo ao solo. Na análise de variáveis categóricas, utilizou-se teste Exato de Fisher e teste de Fisher com a extensão de Freeman-Halton. Foi considerado estatisticamente significante valor de p ≤ 0,05. Em algum grau, todos os pacientes relataram dor à palpação dos músculos temporal e masseter, assim como à palpação da ATM. A presença de alterações na ATM somente apresentou significância estatística na presença de osteófitos na região articular do lado direito em associação com dor na articulação temporomandibular ipsilateral (p=0,04). Erosões e esclerose não foram encontradas em nenhum paciente e aplainamento foi um achado na totalidade dos indivíduos, porém, não apresentando relação estatísticamente significante quando cruzado com achados clínicos. A presença de dor no músculo temporal e a relação horizontal côndilo-fossa contralateral, apresentaram significância estatística (p<0,05). No músculo masseter essa associação apresentou significância estatística com a relação horizontal côndilo-fossa ipsilateral (p=0,01). Os achados sugerem que o bruxismo pode promover alterações significativas nas estruturas do sistema estomatognático desde a infância. / Among the parafunctional activities of masticatory system, bruxism can be higlighted. It occurs during sleep (Sleep Bruxism - SB) or wakefulness (Awake Bruxism - DB), which occur in two different states of consciousness (sleep and wakefulness). The International Classification of Sleep Disorders defines bruxism as \"a movement disorder with a stereotyped pattern of the masticatory system that involves teeth grinding or clenching during sleep.\" Bruxism is clinically diagnosed based on reports of teeth grinding noises that occurred at least three to five nights per week for 6 months. Also, the presence of wear facets, matutinal pain in the masticatory muscles, masseter muscle hypertrophy, temporomandibular joint (TMJ) noise or hypersensitivity, dental impressions on the cheek or tongue and tooth mobility, among others, are hallmarks of this parafunction. However, the evaluation should not be restricted to clinical examination since functional aspects are gaining importance. As consequence, imaging has become an invaluable resource for diagnosis. The objective of this paper is to describe possible changes in temporomandibular joint (TMJ) anatomical components in children with bruxism by Cone Beam Computed Tomography image analysis. Based on the inclusion and exclusion criteria, Twenty 7-11-years old male and female children treated at Ribeirão Preto Pediatric Dentistry Clinic, University of São Paulo, Brazil, were selected. The presence of all or some of the following changes was used in clinical evaluation for bruxism diagnosis in the present study: presence of wear facets, fractures in fillings, dental fractures, dental impressions in cheek and tongue, TMJ pain and clicking, masseter and temporalis muscles pain. The CT scan was performed on a i-CAT CT device and during multiplanar reconstructions, before obtaining image, the total volume of the patient was transferred to the scanner using the Frankfurt plane parallel to the ground. In Statistical analysis Fisher\'s exact test and Fisher\'s test with the Freeman-Halton extension were used for categorical variables. Values of p ≤ 0.05 were considered statistically significant. In the results, all patients reported pain on palpation of the temporalis and masseter muscles, as well as TMJ palpation. Erosions and sclerosis were not found. Flattening was present in all individuals, however, no statistical significance was found between this feature and clinical findings. The presence of osteophytes in the TMJ was associated with ipsilateral pain in temporomandibular joint palpation (p = 0.04). There was an association between pain in the contralateral temporal muscle and the condyle-fossa relationship in the horizontal direction (p <0.05). There was also a correlation between pain in the ipsilateral masseter muscle and the condyle-fossa relationship in the horizontal direction (p = 0.01). In conclusion, our findings suggest that bruxism can promote significant changes in the structures of the stomatognathic system since childhood.
|
56 |
Avaliação da capacidade de identificação de prematuridades oclusais, por meio cortes paraxiais obtidos de tomografias computadorizadas de feixe cônico (Cone Beam)Machado, Naila Aparecida de Godoi 23 February 2010 (has links)
The objective of this study was to evaluate the ability to identify occlusal
prematurity, by cutting the paraxial CT cone beam, comparing the opinion of
these images, provided by professionals in different specialities, with clinical
examination obtained from strips of carbon paper. Sixteen young asymptomatic
patients underwent an initial clinical examination and then were made appliance
desprogramming individual (Lucia JIG). Through manipulation and marking
interocclusal jaw with carbon film (Accufilm) identified clinically premature
contact Centric Relation (CR) of each patient. Later these devices were set in
the position of centric contact and used during the CT scans so that they could
obtain tomographic images in the position of centric relation. After processing
the images, these were analyzed for thirty professionals from different areas
and compared the results obtained by the analysis of imaging and analysis of
clinical markers. The data were statistically analyzed by analysis of variance
ANOVA and Scott-Knott. From the evaluation of the ability to identify occlusal
prematurity through cuts of paraxial CT cone beam, we can conclude that there
was no statistically significant difference between the views of professionals
with clinical examination carried out with carbon paper. Comparing the opinions
expressed by professionals in the areas of occlusion, Radiology and General
Clinicians, notes that there was no statistically significant differences. Regarding
the time of his profession, the group with less time since graduation had the
lowest rate of agreement among the analysis of imaging and clinical analysis
with carbon paper. / O objetivo deste estudo foi avaliar a capacidade de identificação de
prematuridades oclusais, por meio de cortes paraxiais de tomografias
computadorizadas de feixe cônico, confrontando o parecer destas imagens,
estabelecido por profissionais de diferentes áreas odontológicas, com a análise
clínica obtida por meio de marcações com papel carbono. Dezesseis pacientes
jovens assintomáticos foram submetidos a um exame clínico inicial e em
seguida foram confeccionados dispositivos desprogramadores individuais ( JIG
de Lucia ). Mediante manipulação mandibular e marcação interoclusal com
papel carbono (Accufilm) identificou-se clinicamente o contato prematuro em
Relação Cêntrica (RC) de cada paciente. Posteriormente estes dispositivos
foram ajustados na posição de contato cêntrico e utilizados durante os exames
tomográficos para que se pudessem obter imagens tomográficas na posição de
Relação Cêntrica. Após o processamento das imagens, estas foram analisadas
por trinta profissionais das áreas de Oclusão, Radiologia e Clínico Geral (n=10
para cada área) e compararam-se os resultados obtidos pela análise das
imagens tomográficas e pela análise clínica por marcações. Os dados obtidos
foram analisados estatisticamente pela Análise de Variância ANOVA e pósteste
de Scott-Knott (p <0,05). A partir da avaliação da capacidade de
identificação de prematuridades oclusais por meio de cortes paraxiais de
tomografias computadorizadas de feixe cônico, pode-se concluir que não houve
diferenças estatisticamente significantes entre os pareceres dos profissionais
com a análise clínica realizada com papel carbono. Ao comparar os pareceres
emitidos pelos profissionais das áreas de Oclusão, Radiologia e Clínica Geral,
constata-se que não houve diferenças estatisticamente significantes. Em
relação ao tempo de exercício profissional, o grupo com menor tempo de
formado apresentou o menor índice de concordância entre os pareceres da
análise das imagens tomográficas e a análise clínica com papel carbono. / Mestre em Odontologia
|
57 |
Avaliação qualitativa de biomateriais utilizados para enxertia em alvéolos dentais, em mandíbulas de suínos, por meio da tomografia computadorizada Cone Beam / Qualitative evaluation of biomaterials used in pig mandibles dental cavities graftings, by means of Cone-Beam computed tomographyAna Cláudia Azevedo 17 June 2013 (has links)
A invenção da Tomografia Computadorizada revolucionou o método de diagnóstico. Apesar de ser um exame de custo elevado, sua confiabilidade é de grande valia. Na década de noventa foram descritos os primeiros relatos da tomografia computadorizada Cone Beam para o uso na Odontologia. Esses aparelhos de tomografia computadorizada por feixe cônico, Cone Beam ou volumétrica são mais compactos, de menor custo e com menor tempo de exposição à radiação ao paciente, quando comparados aos aparelhos de tomografia computadorizada médica ou Fan Beam. Diante da grande utilização de implantes osseointegrados, algumas dificuldades foram despontando, visto que também paralelamente a este, os defeitos ósseos necessitavam de correção. Então os enxertos ósseos ou biomateriais de enxertia passaram a ser a alternativa que possibilitava a correção dessas perdas ósseas. Com o objetivo de estudar e avaliar qualitativamente os biomateriais de enxertia, inseridos em alvéolos dentais, em mandíbulas de suínos, por meio da tomografia computadorizada Cone Beam, utilizou-se de 20 mandíbulas dissecadas de porco, dos quais foram extraídos quatro dentes e nesses alvéolos foram introduzidos quatro biomateriais de enxertia de composições diferentes, com propriedades físico-químicas distintas, forma física, origem e de classificações diferentes. As mandíbulas de suínos foram submetidas a um exame de tomografia computadorizada volumétrica. As imagens obtidas foram avaliadas por um Software específico. Os resultados mostraram que não existiu diferença entre os cortes C (corte coronal) e S (corte sagital) e entre os cortes SS (corte parassagital) e o corte PAN (corte panorâmico), sendo que os corte C e S tiveram maior observação e os cortes SS e PAN, foram os de menor observação. Quanto ao material M-C (GenPhos HA TCP®, G 50, 0.5cc) foi o que obteve maior média de observação (com média 1, 81) enquanto que o M-B (OrthoGen®, G 75, 0.5cc) foi o mais difícil de ser observado, nos contes C (corte coronal) e S (corte sagital). Em relação a homogeneidade os materiais M-B (OrthoGen®, G 75, 0.5cc) e M-D (GenOx Inorg Esponjoso®) não apresentaram diferenças significativas, sendo portanto os materiais considerados menos homegêneos, quando se referem a densidade; observados nos cortes C (corte coronal) e S (corte sagital). Já os materiais M-C (GenPhos HA TCP®, G 50, 0.5cc) e M-A (Biogran® 300-350m, 50-45 mesh) segundo os p-valores não foram considerados estatisticamente diferentes, portanto os materiais que apresentaram as imagens mais homogêneas, igualmente aos demais materiais, foram observados nos cortes C (corte coronal) e S (corte sagital). O corte PAN (corte panorâmico) com média 1,43, foi a imagem que permitiu uma melhor observação dos biomateriais de enxertia. Todos os avaliadores afirmaram que identificaram o alvéolo ou o biomaterial de enxertia considerando a referência anatômica (lâmina dura). / The invention of Computed Tomography has radically changed the method of diagnosis. Even though it is a high-cost exam, its reliability is really worth it. The first reports about the use of Cone-Beam Computed Tomography in Dentistry were described during the 1990s. These conic bundle, Cone-Beam or volumetric computed tomography devices are more compact, less expensive and provide the lowest radiation dose for the patient when compared to other medical or Fan-Beam computed tomography devices. Once there has been a wide use of osseointegrated implants, some difficulties have emerged as, in parallel to this, there were some bone defects that required correction. Therefore, bone graftings or biomaterials for graftings have become an alternative that allowed correcting bone losses. With the objective to study and evaluate qualitatively the grafting biomaterial inserted pig mandibles dental cavities by Cone-Beam computed tomography, it was used 20 dissected pig mandibles, from which four teeth have been extracted and four biomaterial graftings of different compositions, different physical-chemical properties, physical shape, origin and classifications have been inserted into those cavities. The pig mandibles were submitted to a volumetric computed tomography. Images were evaluated by specific software. Results showed that there was no difference between C (coronal section) and S (sagittal section) sections, and between SS (parassagittal section) and PAN (panoramic section) sections. C and S sections had more observation and SS and PAN sections were the ones with less observation. Concerning the material, M-C (GenPhos HA TCP®, G 50, 0.5cc) was the one that obtained the highest observation average (1,81) while M-B (OrthoGen®, G 75, 0.5cc) was the most difficult to be observed on C (coronal) and S (sagittal) sections. About the homogeneity of materials, M-B (OrthoGen®, G 75, 0.5cc) and M-D (GenOx Inorg Esponjoso®) did not show significant differences, being, therefore, the materials considered the least homogeneous regarding density; observed in C (coronal) and S (sagittal) sections. According to p-values, materials M-C (GenPhos HA TCP®, G 50, 0.5cc) and M-A (Biogran® 300-350m, 50-45 mesh) were not considered statistically different. Thus the materials that presented the most homogeneous images, as well as the other materials, were observed in C (coronal) and S (sagittal) sections. The PAN (panoramic) section, with an average of 1,43, was the image that allowed the best observation of the grafting biomaterials. All evaluators affirmed to have identified the cavity of the grafting biomaterial considering the anatomic reference (hard slide).
|
58 |
Avaliação da tomografia computadorizada Cone Beam como método de proservação de lesões periapicais após o tratamento endodôntico em pacientes com fissura labiopalatina / Evaluation of cone beam computed tomography as a method of follow-up of periapical lesions after endodontic treatment in patient with cleft lip and palateTulio Lorenzo Olano Dextre 29 June 2012 (has links)
O objetivo deste trabalho foi comparar a eficácia da Tomografia Computadorizada Cone Beam e a Radiografia Periapical como métodos de proservação de lesões periapicais após o tratamento endodôntico. Foram avaliadas no estudo Radiografias e Tomografias de 1.462 indivíduos com fissura labiopalatina no Hospital de Reabilitação de Anomalias Craniofaciais Universidade de São Paulo, que compareceram para o tratamento endodôntico entre os anos 2009 e 2011. De acordo com os critérios de inclusão, foram selecionados 46 dentes unirradiculares com lesão periapical, os quais foram divididos nos grupos: avaliação Radiográfica (Grupo I) e avaliação Tomográfica (Grupo II). Os dados foram analisados por meio do escore PAI para as alterações periapicais encontradas. Nos resultados observou-se que houve diferença estatisticamente significativa nos grupos estudados. Em 34 casos os escores atribuídos às Tomografias dos dentes avaliados foram maiores do que os escores atribuídos às Radiografias Periapicais dos mesmos dentes avaliados, comprovando a maior precisão da Tomografia Computadorizada Cone Beam. Desta forma, a análise dos resultados obtidos neste trabalho permite constatar que a Tomografia Computadorizada Cone Beam é mais eficaz na proservação de lesões periapicais do que a Radiografia Periapical após o tratamento endodôntico em pacientes com fissura labiopalatina. / The aim of this study was to compare the effectiveness of Cone Beam Computed Tomography and periapical radiography as a follow-up method of periapical lesions after endodontic treatment. We evaluated in the study radiographs and tomography scans of 1,462 individuals with cleft lip and palate at the Hospital of Rehabilitation of Craniofacial Anomalies - University of Sao Paulo who came for treatment endodontic between the years 2009 and 2011. According to inclusion criteria were selected 46 single-rooted teeth with periapical lesions, which were divided into groups radiographic evaluation (Group I) and tomographic evaluation (Group II). Data were analyzed using the PAI score for periapical changes found. The results were observed that statistically significant differences in the groups studied. In 34 cases the CT scores attributed to the teeth evaluated were higher than the scores attributed to the radiographs of same teeth evaluated, demonstrating the greater precision of Cone Beam Computed Tomography. Thus, analysis of results obtained in this work demonstrates that the Cone Beam Computed Tomography is more effective in follow-up of periapical lesions than periapical radiography after endodontic treatment in patients with cleft lip and palate.
|
59 |
Estudo comparativo entre a tomografia volumétrica Cone Beam e radiografias periapicais no auxílio ao diagnóstico endodôntico / Comparative study between Cone-Beam volumetric tomography and periapical radiographs on helping endodontic diagnosisD’Addazio, Paulo Sérgio dos Santos 30 January 2009 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-10-07T19:23:21Z
No. of bitstreams: 1
paulosergiodossantosdaddazio.pdf: 1362518 bytes, checksum: 07214ba3207394666338f0eeb8fcbd4e (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-10-11T15:49:18Z (GMT) No. of bitstreams: 1
paulosergiodossantosdaddazio.pdf: 1362518 bytes, checksum: 07214ba3207394666338f0eeb8fcbd4e (MD5) / Made available in DSpace on 2016-10-11T15:49:18Z (GMT). No. of bitstreams: 1
paulosergiodossantosdaddazio.pdf: 1362518 bytes, checksum: 07214ba3207394666338f0eeb8fcbd4e (MD5)
Previous issue date: 2009-01-30 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este estudo objetivou analisar comparativamente a tomografia volumétrica Cone-Beam e o exame radiográfico periapical, pela técnica de Clark, quanto à identificação de acidentes e complicações endodônticas, simuladas, de interesse endodôntico. Dezesseis dentes humanos, em três mandíbulas humanas, foram submetidos ao preparo de 20 alterações/lesões, de modo a simular situações que podem constituir-se em complicações para o diagnóstico e tratamento endodôntico. As simulações foram divididas em quatro grupos: G1) fragmento de lima fraturada no conduto radicular; G2) perfurações/rasgos no conduto radicular; G3) núcleos metálicos com desvio em relação ao trajeto do canal radicular e; G4) reabsorções externas. Cada dente foi submetido a exame radiográfico periapical pela técnica de Clark e cada mandíbula, a exame por Tomografia Computadorizada Cone-Beam. A análise dos exames foi realizada por um único observador, especialista em radiologia odontológica. Os resultados gerais utilizando-se o teste estatístico de McNemar demonstraram diferença estatisticamente significante (p < 0,05) para a Tomografia Computadorizada Cone-Beam em relação às radiografias periapicais. A análise estatística dos resultados individuais por alteração/lesão, utilizando-se o teste estatístico de Wilcoxon, demonstrou que houve superioridade da Tomografia Computadorizada Cone-Beam na identificação de reabsorções, com valor estatisticamente significante (p < 0,05). De acordo com os resultados pode-se concluir que, de uma forma geral, a Tomografia Computadorizada Cone-Beam apresentou superioridade em relação às radiografias periapicais convencionais, na identificação das alterações/lesões simuladas. / This study aimed to analyze and compare volumetric tomography ConeBeam and periapical examination, by technique of Clark, identifying accidents and endodontic complications, which were simulated, for endodontic interest. Sixteen human teeth from three human jaws were submitted to preparation of 20 changes/injuries in order to simulate situations that can lead to complications for diagnosis and endodontic treatment. The simulations were divided into four groups: G1) fragment of fractured file in radicular duct; G2) holes/slots in radicular duct; G3) metal cores with deviation from the path of root canal and, G4) external resorption. Each tooth was submitted to examination of periapical radiography, by technique of Clark and each jaw, by the examination of Cone-Beam Computed Tomography. The analysis of the tests was performed by a single observer, a specialist in dental radiology. The overall results using McNemar statistical test showed a difference statistically significant (p < 0.05) for Cone-Beam Computed Tomography if compared to periapical radiographs. Statistical analysis of individual results for alteration/defect, using Wilcoxon statistical test showed superiority of Cone-Beam Computed Tomography to identify resorptions, with statistically significant value (p < 0.05). According to the results it can be concluded that, generally, the Cone-Beam Computed Tomography showed superiority in relation to conventional periapical radiographs, identifying simulated changes/injuries.
|
60 |
Usefulness of dental cone beam computed tomography (CBCT) for detetion of the anatomical landmarks of the external, middle and inner earTaleb Mehr, Mahdieh 01 May 2013 (has links)
Thesis problem: Cone beam computed tomography (CBCT) can provide images with identical information and considerable dose reduction compared with reasonably low costs compared to multislice computed tomography (MSCT) especially where multiple follow up imaging studies are needed. The purpose of this study was to evaluate the diagnostic usefulness of CBCT, using i-CAT®'s software, for detection of the anatomical landmarks of the external, middle and inner ear to answer this question whether MSCT Can be replaced by dental CBCT for evaluation of the temporal bone.
Material and methods: Cone beam computed tomography (CBCT) images of 63 subjects made with the same machine, with unknown clinical histories and no evidence of pathosis on CBCT images, were evaluated by two oral and maxillofacial radiologists retrospectively. Seven anatomical points (scutum, oval window, incudomalleolar joint, the tympanic/horizontal and mastoid/vertical segments of the facial nerve, anterior and posterior crura of stapes) of the right and left temporal bone (total of 120 temporal bones) were evaluated. The results were provided as percentage of the points identified by each radiologist. The intra and inter observer agreement were calculated using kappa statistic.
Results: The scutum, the tympanic/horizontal segment of the facial nerve canal and the oval window of the right and left temporal bone of 63 cases (total 126 temporal bones) were visualized by the first observer as well-defined structures in 100%, 96.03% and 100% of the cases, respectively. The tympanic/horizontal segment of the facial nerve canal was visualized as a poorly-defined structure in 2.38 % and could not be identified in 1.59% of the cases. The anterior and posterior crura of stapes, the mastoid/vertical segments of the facial nerve canal and the incudomalleolar joint were visualized as well-defined structures in 24.60%, 53.17%, 99.21% and 57.94% of the cases, as poorly defined structures in 32.54%, 41.27%, 0.79% and 39.68% of the cases respectively. The anterior and posterior crura of stapes, the mastoid/vertical segments of the facial nerve canal and the incudomalleolar joint could not be identified in 42.86%, 5.56%, 0% and 2.38% of the cases respectively. The intra- and inter-observer agreement ranged from strong for tympanic/horizontal and mastoid/vertical segments of the facial nerve canal to poor for the anterior and posterior crura of stapes and also the incudomalleolar joint.
Conclusion: The i-CAT CBCT machine is a promising replacement for MSCT in evaluation of the temporal bone where there is no need for evaluation of the anterior and posterior crura of stapes and the incudomalleolar joint which are the smallest anatomical structures in the temporal bone. Other CBCT machines with higher contrast to noise ratio should be evaluated for detection of those anatomical structures since CBCT can reduce the patient dose substantially where multiple follow up CT studied are needed.
Key words: Computed tomography; cone beam CT; multislice helical CT; middle ear; inner ear; temporal bone.
|
Page generated in 0.0508 seconds