Spelling suggestions: "subject:"consumo dde água"" "subject:"consumo dee água""
1 |
Uso eficiente da água nos edifíciosMartins, Daniel Guedes dos Santos January 2009 (has links)
Estágio realizado na Edifícios Saudáveis - Consultores e orientado pelo Eng.º Ricardo Sá e Arquitecto Jeann Vieira / Tese de mestrado integrado. Engenharia do Ambiente. Faculdade de Engenharia. Universidade do Porto. 2009
|
2 |
Análise dos consumos de água em edifícios não habitacionaisSoares, Adão Miguel Monteiro January 2010 (has links)
Tese de mestrado integrado. Engenharia Civil. Faculdade de Engenharia. Universidade do Porto. 2010
|
3 |
Demanda hídrica do caupi (Vigna unguiculata (L) Walp, cult. V-69) em área do trópico úmido brasileiro / Water requirements of cowpea (Vigna unguiculata (L) Walp, Cult. V-69) crops in a humid tropical area of BrazilIgreja, Sara Maria Siqueira da 22 December 1987 (has links)
No presente trabalho determinou-se experimentalmente o consumo de água de uma cultura do caupi (Vigna unguiculata (L) Wa1p), sem restrição hídrica no solo, em duas épocas de plantio (maio-julho e setembro novembro/ 1985) em Belem/PA 1°28 S, longitude 47°55 W e altitude 12,8 m acima do nível do mar). Para cada época foi medida a evapotranspiração máxima (ETm) através de evapotranspirômetros tipo Thornthwaite. Foram estimadas, para cada época, a evapotranspiração de referência pelos métodos de Penman, de Thornthwaite, do tanque classe A, de Hargreaves, de Linacre, de Benavides & Lopez, da radiação solar, de Turc e de Makking. Na segunda época foi também medida a evapotranspiração de referência (ETo) pelo uso de evapotranspirômetros cobertos com grama. Na comparação entre métodos de estimativa de ETo com os valores medidos desse parâmetro, na segunda época de plantio, verificou-se que os métodos de Makking e de Linacre forneceram valores estatisticamente diferentes dos medidos, enquanto o da radiação solar esteve no limite da significância estatística; os três forneceram sub-estimativas de ETo em relação aos valores medidos. Os outros métodos forneceram valores de ETo estatisticamente não diferentes dos medidos, mas o de Thornthwaite e o de Benavides & Lopez foram os que deram valores mais próximos aos de ETo medidos sendo que os de Penman e de Turc tenderam a fornecer sub-estimativas, enquanto o do tanque classe e o de Hargreaves tenderam a fornecer super-estimativas. A evapotranspiração máxima do caupi foi de 206,76 e 276,76 mm no ciclo, para a primeira e segunda épocas de plantio, respectivamente, com valores médios de 3,69 e 4,33 mm/dia. O maior consumo na segunda época pode ter sido de corrente de maiores valores de radiação global e de um número maior de plantas nos evapotranspirômetros nessa época. Os valores de coeficiente de cultura (Kc-relação ETm/ETo) variaram ao longo do ciclo da Caupi, partindo de valores em torno de 0,5-0,6 nos estádios iniciais até valores máximos nos estádios de emissão de botões florais, abertura das flores e formação das vagens, diminuindo posteriormente. Os valores máximos de Kc variaram entre 1,1 e 1,6 nas duas épocas de plantio, dependendo do método utilizado na estimativa de ETo. Os métodos de Makking, de Linacre e da radiação solar super-estimaram sistematicamente, os valores de Kc, além de fornecerem valores de Kc estatisticamente diferentes quando comparados com os valores de Kc obtidos via ETo medida, na segunda época de plantio. Os valores de Kc obtidos a partir dos outros métodos não diferiram estatisticamente do Kc obtido via ETo medido, sendo que o de Thornthwaite e o de Benavides & Lopez deram estimativas com menor desvio. Esses dois métodos, mais o de Hargreaves e o do tanque classe A foram os que forneceram valores máximos de Kc mais próximos dos valores sugeridos pela FAO para Phaseolus vulgaris L. (espécie da mesma família do caupi). / The water consumption was experimentally determined for a cowpea (Vigna unguiculata (L) Walp) crop, under condition of non-restricted soil water, at two planting times (May-July and September-November1985), in Belem - State of Pará (latitude 1°28'S, longitude 47°55'W and altitude 12.8 m above sea level). The·maximum evapotranspiration (ETm) was measured for each planting time through Thornthwaite-type evapotranspirometers. For each time the reference evapotranspiration was estimated by the methods of Penman, Thornthwaite, Class-A Pan, Hargreaves, Linacre, Henevides & Lopez, solar .radiation, Ture, and Makking. At the second planting time also the reference evapotranspiration (ETo) was measured with grass-covered evapotranspirometers. When estimated values of ETo were compared with the measured values it was observed that the methods of Makking and of Linacre provided values which were statistically different from those measured, s61ar radiation method reached the limit of while the statistical significance; the three methods under-estimated ETo as compared to the measured values. The other methods utilized provided ETo values which were not statistically different from those measured, but the' Thornthwaite method and Benevides & Lopez method provided values which were closest to the measured values of ETo; the methods of Penman and of Ture showed a tendency to give under-estimates, while the Class-A Pan method and the Hargreaves method showed a tendency to provide over-estimates. The maximum evapotranspiration for cowpea was 206.76 and 27676 mm during its cycle, for the first and the second planting times, respectively, with mean values of 3.69 and 4.33 mm/day. The higher consumption in the second planting time may be a consequence of higher values of solar radiation and of a larger number of plants on the evapotranspirometer at the time. The crop coefficient values (ratio ETm/ETo) varied along the cowpea cycle, from values around 0.5-0.6 in the early stages to maximum values at flower-budding, flowering and pod formation, subsequently decreasing. The maximum values of Kc varied from 1.1 to 1.6 in the two planting times, as a consequence of the method utilized for estimating ETo. The methods of Makking, of Linacre and of solar radiation systematically overestimated the Kc values in addition to showing statistically different Kc values, when compared with those obtained from the measured value of ETo at the second planting time. The Kc values obtained through the other methods did not statistically differ from the Kc values, obtained via measured ETo; the Thornthwaite method and the Benevides & Lopez method provided estimates with smaller deviations. The methods of Thornthwaite, Benevides & Lopez, Hargreaves and the Class-A Pan method provided maximum Kc values which were closest to the values suggested by FAO for Phaseolus vulgaris (a species of the same family of the cowpea).
|
4 |
Consumo de água do maracujazeiro amarelo (Passiflora edulis Sins var flavicarpa Deg) / Water consumption of yellow passion fruit (Passiflora edulis Sins var flavicarpa Deg)Alencar, Cristina Miranda de 29 May 2000 (has links)
Este trabalho teve como objetivo estimar a evapotranspiração da cultura (ETc) do maracujazeiro amarelo em lisímetros de drenagem e o coeficiente de cultivo (Kc) durante a fase de desenvolvimento da mesma. O experimento foi conduzido na área experimental da Fazenda Areão pertencente à ESALQIUSP, em Piracicaba-SP. A determinação da ETc foi feita em 4 lisímetros de drenagem instalados no centro de uma área de 0,4 ha cultivada com maracujazeiro amarelo, com espaçamento de 3,5 m x 4,0 m. Os cálculos de Kc foram determinados a partir da ETc e da evapotranspiração de referência (ETo) estimada pelo método de Penmam-Monteith. No período entre 32 e 76 dias após o transplantio (DAT) foram verificados baixos valores de ETc (0,39 a 0,79 mm dia-1) devido provavelmente a ocorrência de baixas temperaturas e radiação solar. A partir dos 77 DAT os valores de evapotranspiração de cultura (ETc) foram sempre crescentes atingindo o valor máximo de 4,68 mm dia-1 no período compreendido entre os 182 e 196 DAT, início da floração e frutificação. A ETc do maracujazeiro foi proporcional ao crescimento da área foliar. Os valores médios de Kc variaram entre 0,38 e 1,10 para os períodos 21/05 a 04/06 e 02/11 a 16/11, respectivamente, cuja variação teve o mesmo comportamento da ETc. / The goal of this work was to estimate the culture evapotranspiration (ETc) of the yellow passion fruit in drainage lisymeters and the crop coefficient (Kc) during the development phase. The experiment was carried out at the Fazenda Areão ESALQ/USP in Piracicaba, São Paulo state. For drainage lisymeters were installed in the, center of a 0.4 ha area for ETc determination. ETc and the reference evapotranspiration (ETo) estimated by the Penmam-Monteith utilized to find the Kc values. Lower values of ETc (0.39 a 0.79 mm day-1) were verified in the period among 32 and 76 day after planting (DAT) probably due to the occurrence of low temperatures and solar radiation. Starting in 77 DAT, the culture evapotranspiraton (ETc) increased and the maximum value was 4.68 mm day-1 in the period among 182 and 196 DAT, beginning of flowering and fruit emergence. The ETc of the passion fruit increased with the emission of leaves and growth of the leaf area. The medium Kc values ranged 0.38 and 1.10 from periods 05/21 through 06/04 and 11/02 through 11/16, respectively, and variation had the same ETc.
|
5 |
Determinação do consumo de agua na cultura do trigo (triticum estivum, L. ) através de lisímetro / Determination of wheat water consumption (triticum aestivum L. ) in lysimeterCosta, Maurice Barcellos da 05 September 1989 (has links)
A finalidade do presente trabalho, realizado no Campus da ESALQ/USP em Piracicaba, Estado de São Paulo (22° 42' 30"S; 470 38' W e 576m nm), foi obter parâmetros que permitissem estimar a demanda evapotranspirativa da cultura do trigo. Para tanto, foram utilizados três lisímetros com nível freático constante, através, dos quais obtivemos valores diários da evapotranspiração máxima da cultura e constatamos que no final do ciclo vegetativo, os valores totais do consumo de água não diferiram estatisticamente entre si, e apresentaram valor médio igual a 347,20mm.Os valores da evapotranspiração máxima da cultura (ETm) obtidos foram correlacionados com os valores da evapotranspiração de referência (ET0) estimados através dos seguintes métodos: Método de Tanque Classe A (ET0cA) ; Método de Radiação solar (ET0Rs) ; Método de Penman (ET0Pn) ; Método de Penman modiricado (ET0Pn*</sup ) e Método de Thornthwaite (ET0Th) .Os valores das estimativas da ET0 para as fases de estabelecimento, perrilhamento, emborrachamento, floração, formação dos grãos e maturação, apresentavam diferença significativa entre ET0Rs e T0Th, e entre estes com os demais métodos, que não diferiram entre si. Os valores de ET0Rs com média igual a 4,34 mm/dia superaram os demais. Os valores de ET0Th com média igual a 2,03 mm/dia foram inferiores. Os valores de ETC0A, ET0Pn e ET0Pn *, apresentaram médias respectivamente iguais a: 3 ,12 mm, 3,34 mm e 3,42 mm. Os valores dos coericientes de cultura (Kc), obtidos pela relação entre a evapotranspiração máxima da cultura (ETm) e as estimativas da evapotranspiração de referencia (ET)0) apresentaram diferenças signiricativas, com os valores de KcTh superando os demais, com média igual a 1.40, os valores de KcRs abaixo dos demais s, com média a igual a 0.55 e os valores de KccA, KcPn e KcPn*</sup que estatisticamente não apresentaram diferenças significativas tiveram médias as respectivamente iguais a: 0.78, 0.73 e 0.70. / The purpose of the present work, performed at ESALQ/USP in Piracicaba, state São Paulo of (22'°' 42'30"° S; 47'' 38'W e 576m), was to obtain parameters to estimate evapotranspiration of wheat crop. Therefore, three constant water table level lysimetes were used, and maximum daily evatransporation values were obtained for the wheat crop. It was concluded trat at the end of the vegetative cycle, total values of the water consumption were not statistically different among them and presented mean value of 347,20 mm. Maximum obtained evapotranspiration values (ETo) estimated by the following methods; Class A Pan Method, Solar Radiation Method, Penman Method, Modified Penman Method and Thornthwaite Method. The Methods Class A Pan, Penman and Modified Penman were the more adequated for study by water requiriments with wheat crop
|
6 |
Referenciais para os níveis de consumo de água sustentáveis em edifícios de habitaçãoFerreira, Frederico António Araújo January 2012 (has links)
Tese de mestrado. Mestrado integrado em Engenharia Civil - Especialização em Construções Civis. Faculdade de Engenharia. Universidade do Porto. 2012
|
7 |
Avaliação do consumo de água, racionalização do uso e reúso do efluente líquido de um frigorífico de suínos na busca da sustentabilidade socioambiental da empresaKrieger, Elisabeth Ibi Frimm January 2007 (has links)
O consumo de água nas indústrias alimentares é intenso devido às rigorosas exigências sanitárias, porém muitas vezes excessivo. Tendo em vista a crescente escassez de água, procedimentos de racionalização do uso da água e reúso de efluentes devem ser implantados, observando o cumprimento da legislação sanitária. O objetivo do trabalho, realizado em um frigorífico de suínos, com abate de 1.150 suínos/dia, localizado no sul do Brasil, consistiu em determinar um índice de consumo de água, bem como avaliar as características físicas, químicas e biológicas do efluente tratado com vistas ao reúso no processo produtivo e áreas de utilidades. Os resultados mostraram que o consumo de água é de 776 L/suíno, podendo ser reduzido para 480 L/suíno, através da implementação de técnicas de produção mais limpa, possibilitando atingir os seguintes percentuais de redução: nos processos de limpeza e sanitização (81%), na lavagem de pocilgas, dessedentação de suínos e lavagem de caminhões (64%), no atordoamento e sangria (79%), na evisceração e divisão (55%), no processamento das tripas (47%) e nas operações de escaldagem e depilação (31%). A operação das torres de resfriamento deve ser otimizada, devido ao elevado consumo de água (26% do total). Os parâmetros físicos, químicos e biológicos do efluente tratado foram analisados, seguindo os procedimentos descritos por APHA (2005), concluindo-se que há necessidade de otimizar o sistema de tratamento de efluentes, principalmente para a redução do conteúdo de sais, com vistas ao reúso da água. As medidas de racionalização e otimização do processo produtivo e os procedimentos de reúso propostos, contribuem para a redução da carga poluidora lançada na Bacia Hidrográfica do rio da Várzea e buscam a sustentabilidade socioambiental da empresa. / The water consumption in the food industry is intense due to strict sanitary regulations, but usually excessive. In a world where the water is becoming a rare commodity it is necessary to implement procedures that allow a better use of this resource without causing sanitary concerns. This study was performed in a pig slaughterhouse located in Southern Brazil, with a slaughter capacity of 1150 pigs per day. Its major focus was the determination of the specific and global water consumption and the suitability of the treated wastewater to fulfill water uses in the plant. The water consumption in the facility of 776 L/pig was determined and the observations in the process showed that, with the implementation of the cleaner production recommendations, it would be possible to reduce it to 480 L/pig. According to the proposals here presented the reductions in the water consumption could reach: cleaning and sanitizing (81%), holding pens washing, pigs watering and trucks washing (64%), stunning and bleeding (79%), evisceration and splitting (55%), casing processing (47%) and scalding and dehairing (31%). When compared to literature data, the operation of the cooling towers should be improved due to the great water consumption (26% of total). The physical, chemical and biological parameters of the treated wastewater were analyzed following procedures described by APHA (2005), and, when compared to requirements for different water uses, its quality showed that, in order to be reused in the facility, additional treatment is needed, mainly for the reduction of the salt content. The measures of rationalization and optimization of the productive process and the proposed procedures of water reuse contribute for the reduction of pollution discharge in the Hydrographic Basin of Várzea River and look for a social environmental sustainability of the company.
|
8 |
Níveis de sódio e cloro para codornas italianas destinadas à produção de carne / Levels of Italian sodium and chlorine for codornas destined the meat productionRaquel, Débora Linhares January 2009 (has links)
RAQUEL, D. L. Níveis de sódio e cloro para codornas italianas destinadas à produção de carne. 2009. 69 f. Dissertação (Mestrado em Zootecnia) - Centro de Ciências Agrárias, Universidade Federal do Ceará, Fortaleza, 2009. / Submitted by Daniel Eduardo Alencar da Silva (dealencar.silva@gmail.com) on 2014-12-08T18:51:37Z
No. of bitstreams: 1
2009_dis_dlraquel.pdf: 212036 bytes, checksum: f146c112940c75dac0f874f9d88e78b2 (MD5) / Approved for entry into archive by José Jairo Viana de Sousa(jairo@ufc.br) on 2016-01-29T20:20:35Z (GMT) No. of bitstreams: 1
2009_dis_dlraquel.pdf: 212036 bytes, checksum: f146c112940c75dac0f874f9d88e78b2 (MD5) / Made available in DSpace on 2016-01-29T20:20:35Z (GMT). No. of bitstreams: 1
2009_dis_dlraquel.pdf: 212036 bytes, checksum: f146c112940c75dac0f874f9d88e78b2 (MD5)
Previous issue date: 2009 / Two experiments were conducted to determine the best sodium and chlorine nutritional levels to Italian quails for meat production (aged 1 to 49 days). In each trial, 384 one-day quails were distributed in a completely randomized design with six treatments and eight replications of eight birds of experimental unit. The levels of sodium and chlorine evaluated were: 0,07; 0,12; 0,17; 0,22; 0,27 and 0,32%. It was observed a quadratic effect of the sodium levels on feed intake, weight gain and yields of carcass and thigh plus drumstick, with optimal levels of 0,257%, 0,216%, 0,207% and 0,191% respectively. The increase in sodium level in the diet produced a linear decrease in feed conversion and an in increase in water intake. However, the excreta moisture and breast yield were not significantly affected by the sodium levels. As for chlorine, we did not observe any significant effects of the chlorine levels in the diets on all the parameters evaluated. From the results, we can recommend that the diets for Italian quails bred for meat production, in the phase from 1 to 49 days, are formulated with 0,22% of sodium level and chlorine levels from 0,07% to 0,32%. / Dois experimentos foram conduzidos para determinar os melhores níveis nutricionais de sódio e cloro para codornas italianas destinadas à produção de carne (1 a 49 dias de idade). Em cada experimento, 384 codornas com um dia de idade foram distribuídas em um delineamento inteiramente casualizado, com seis tratamentos e oito repetições de oito aves por unidade experimental. Os níveis de sódio e de cloro avaliados foram: 0,07; 0,12; 0,17; 0,22; 0,27 e 0,32%. Observou-se efeito quadrático dos níveis de sódio sobre o consumo de ração, ganho de peso e sobre os rendimentos de carcaça e coxa+sobrecoxa, com níveis ótimos de 0,257%, 0,216%, 0,207% e 0,191%, respectivamente. O aumento do sódio na ração promoveu prejuízo linear na conversão alimentar e aumento na ingestão de água. Entretanto, a umidade das excretas e o rendimento de peito não foram afetados significativamente pelos níveis de sódio. Para o cloro, não foram observados efeitos significativos dos níveis de cloro das rações sobre todos os parâmetros avaliados. Considerando os resultados, pode-se recomendar que as rações para codornas italianas destinadas à produção de carne, na fase de 1 a 49 dias, sejam formuladas com 0,22% de sódio e níveis de cloro entre 0,07% a 0,32%.
|
9 |
Proposta metodológica de cálculo para a pegada hídrica na construção civil imobiliária / Methodological proposal for calculating the water footprint in the real estate constructionSouza, Jackeline Lucas 11 December 2016 (has links)
SOUZA, J. L. Proposta metodológica de cálculo para a pegada hídrica na construção civil imobiliária. 205 f. 2014. Tese (Doutorado em Engenharia Civil: Recursos Hídricos) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2014. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2016-02-01T17:35:14Z
No. of bitstreams: 1
2014_tese_jlsouza.pdf: 6578439 bytes, checksum: 5f6ee81d68d4315090b1faf453c14bbd (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2016-02-02T14:01:02Z (GMT) No. of bitstreams: 1
2014_tese_jlsouza.pdf: 6578439 bytes, checksum: 5f6ee81d68d4315090b1faf453c14bbd (MD5) / Made available in DSpace on 2016-02-02T14:01:02Z (GMT). No. of bitstreams: 1
2014_tese_jlsouza.pdf: 6578439 bytes, checksum: 5f6ee81d68d4315090b1faf453c14bbd (MD5)
Previous issue date: 2016-12-11 / This paper aims to propose a calculation methodolog
y to measure the water footprint (PH) in
the real estate construction activity. The water fo
otprint is an empirical quantity indicator, the
period and the place where the water is consumed an
d polluted, which is measured over the
entire productive chain of a product showing not on
ly the volume of water, as well as the type
of water use (consumptive, rain, surface or undergr
ound, or water pollution), the location and
the time when water was used. To calculate the wate
r footprint in housing construction activity
was used the methodology of Hoekstra et al. (2011)
using the partial concept of 'blue water' - a
kind of measure of ownership of the water footprint
determined by consumption, evaporation
and runoff into the ocean - in its use / consumptio
n for human purposes in order to estimate the
quantum of water is required to produce a residenti
al building. The measurement was divided
into three groups that make up civil construction a
ctivity, namely: labor, materials and services.
The results showed statistically that a sample of 9
0 workers could be extrapolated to the average
of workers employed throughout the work (115 employ
ees), allowing to measure the volume
of water consumption (water footprint) for the grou
p of hand work was 1124068200.0 l of water
(distributed direct and indirect) for the materials
group consisting of 128 items that have water
component, the water footprint was 30,100,539.5 l o
f water (Indirect) and for the service group,
consisting of 92 items that use water, the water fo
otprint was 584,427,948.4 l of water (Direct),
ie the total of the enterprise the water footprint
of 1738596688.0 l . The most relevant
consumption workmanship were given to the categorie
s 'liquid' and 'other higienes' in PH Direct
and 'industrialized' and 'transport' in PH Indirect
; for the most outstanding materials was
evidenced in 'irons CA' (PH Indirect), and in servi
ces, the largest water consumption was
evident in the service of 'mechanical protection' (
PH Direct). The total amount of water
consumption (1738596688.0 l) divided by the total a
rea of the project (in m
2
) resulted in
93978.2 l / m
2
, where the housing unit of 157.14 m
2
has a water footprint of 14,767. 734.2 l and
167.12 m
2
one water footprint of 15705636.8 l. It follows th
at the water footprint is a calculation
method capable of measuring the volume of water con
sumed in construction activity, allowing
builders estimate this volume from the work plannin
g stage in order to manage this scarce
environmental resource. / O presente trabalho tem como objetivo propor uma metodologia de cálculo para mensurar a pegada hídrica (PH) na atividade de construção civil imobiliária. A pegada hídrica é um indicador empírico da quantidade, do período e do local onde a água é consumida e poluída, que é medido ao longo de toda a cadeia produtiva de um produto, mostrando não só o volume de água, como também o tipo de uso da água (consuntivo, de chuva, superficial ou subterrânea, ou a poluição da água), a localização e o momento em que a água foi usada. Para calcular a pegada hídrica na atividade de construção civil imobiliária foi utilizada a metodologia de Hoekstra et al. (2011), utilizando o conceito parcial de ‘água azul’ – um tipo de medida de apropriação da pegada hídrica determinada pelo consumo, pela evaporação e pelo escoamento para o oceano – em seu uso/consumo para propósitos humanos, a fim de estimar o quantum de água é necessário para produção de um edifício residencial. A medição foi segregada em três grupos que compõem a atividade de construção civil, sendo estes: mão de obra, materiais e serviços. Os resultados comprovaram, estatisticamente, que uma amostra de 90 trabalhadores da mão de obra pôde ser extrapolada à média de trabalhadores utilizados ao longo da obra (115 trabalhadores), permitindo mensurar o volume de consumo de água (pegada hídrica) para o grupo mão de obra de 1.124.068,2 m3 de água (distribuída em Direta e Indireta), para o grupo materiais formados por 128 itens que possuem componente hídrico a pegada hídrica de 30.100,5 m3 de água (Indireta) e para o grupo serviços formados por 92 itens que utilizam água em suas execuções a pegada hídrica de 584.423,1 m3 de água (Direta), ou seja, no total do empreendimento a pegada hídrica de 1.738.591,8 m3. O montante total de consumo de água (1.738.591,8 m3) dividido pela área total do empreendimento (em m2) resultou em 93,98 m3/m2. Conclui-se que a pegada hídrica é uma metodologia de cálculo capaz de mensurar do volume de água consumido na atividade de construção civil permitindo que esse volume seja estimado na fase de planejamento da obra para melhor fornecimento pelos órgãos públicos de gestão, para estimativa mais próxima do real da extração voluntária que empresas de engenharia precisam realizar na perfuração de poços e para avaliar possíveis impactos ambientais desse recurso escasso.
|
10 |
IMPACTO DO REUSO DE ÁGUA NO BALANÇO HÍDRICO DE UMA EDIFICAÇÃO CORPORATIVA DE GRANDE PORTE EM VITÓRIA-ESSOBREIRA, R. G. 16 July 2015 (has links)
Made available in DSpace on 2016-08-29T15:32:16Z (GMT). No. of bitstreams: 1
tese_9054_DISSERTAÇÃO_Romena_rev 01 (1).pdf: 3955080 bytes, checksum: ad608bd4815d0000078d40135a026e2b (MD5)
Previous issue date: 2015-07-16 / A situação de escassez de água no Brasil tem se intensificado com o crescimento populacional concentrado nos centros urbanos, demandando uma quantidade cada vez maior de água que muitas vezes não é aproveitada eficientemente em virtude da falta de planejamento. Diante do contexto de desenvolvimento sustentável a utilização de recursos hídricos representa um desafio para a sociedade brasileira e envolve vários aspectos relacionados às condições sociais e econômicas. Uma forma de prevenir a escassez de água é através da aplicação de uma gestão integrada, incentivando o uso racional dos recursos hídricos e favorecendo o desenvolvimento de sistemas sustentáveis. O uso de fontes alternativas se apresenta como uma opção ecologicamente correta e dentro dos princípios do desenvolvimento sustentável para suprir demandas de água menos nobres. Os edifícios possuem uma diversidade de atividades nas quais águas menos nobres podem ser usadas, representando grande parte da demanda de edifícios residenciais e comerciais, dando destaque para os usos com irrigação de áreas verdes, lavagem de pisos de garagem e carros, descarga em bacias sanitárias água de reposição em torres de resfriamento e lavagem de roupas. O presente estudo visa estudar os efeitos da conservação de água decorrentes de um sistema de reuso de esgoto sanitário implantado em um edifício corporativo de grande porte, a partir
da avaliação do consumo de água potável, produção de esgoto e água não potável. Além disso, também foram avaliados os custos de operação e manutenção do um sistema de reuso predial que trata esgoto sanitário a fim de se realizar um estudo de viabilidade econômica do sistema. Os resultados obtidos indicam que o consumo de água de reúso representa uma pequena parcela do consumo de água na edificação estudada, cerca de 6% do total consumido. Constatou-se também que a utilização de água de reúso para os fins não potáveis resultou em um coeficiente de retorno de 0,50 e em um índice de consumo per capita de água potável de 112,9 l/pessoa.dia. Esses resultados não são considerados satisfatórios em razão do baixo volume de
água de reuso produzida pela ETE+R, o que gerou um fluxo de caixa negativo
indicando inviabilidade financeira do sistema, uma vez que este durante o período de estudo funcionou baixo da sua capacidade de operação. Assim foram elaborados três cenários para avaliar a viabilidade do sistema: operações com 50%, 75% e 100% de sua capacidade. A analise dos três cenários indicou um VPL > 0, a TIR superior a taxa mínima de atratividade e um Payback inferior a quatro anos nos três cenários. Dessa forma concluiu-se que o sistema de reúso predial representa uma alternativa viável para promover o uso sustentável da água, contribuindo para a melhoria da qualidade do meio ambiente e gerando, ainda, benefícios econômicos
aos usuários.
|
Page generated in 0.0601 seconds