• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 26
  • 4
  • 4
  • 3
  • 2
  • 1
  • 1
  • Tagged with
  • 54
  • 54
  • 21
  • 18
  • 17
  • 13
  • 9
  • 9
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Photoacoustic Imaging Using Chirp Technique: Comparison with Pulsed Laser Photoacoustics

Lashkari, Bahman 10 January 2012 (has links)
The application of photoacoustic (PA) phenomena to medical imaging has been investigated for more than a decade. To implement this modality, one may choose between two types of laser sources, pulsed or continuous wave (CW). This selection affects all features of the imaging technique. Nowadays pulsed lasers are the state-of-the-art technique in the PA research. In this work, various features of the alternative frequency-domain (FD) PA were investigated. An axially symmetric transfer function model of PA wave generation and a Krimholtz-Leedom-Matthaei (KLM) transducer model were developed and used to analyze the experimental results. The controllable parameters of the FD-PA were optimized to improve the signal-to-noise ratio (SNR), contrast, axial resolution and depth detectivity. For example, it was shown that employing the optimal chirp bandwidth can enhance the SNR by more than 10 dB. In addition to the image produced by the cross-correlation amplitude, the phase of the correlation signal was used as a separate channel. A statistical method was introduced to generate an image from this phase channel, and also to filter the PA amplitude channel. A study was also performed to compare FD PA and the prevalent pulsed method. Various features of both methods were examined experimentally using a dual-mode PA system and under the condition of maximum permissible exposure (MPE). The SNRs of both methods were evaluated theoretically and experimentally. It was shown that at low frequencies, both modalities generate comparable SNRs, and at high frequencies pulsed PA produces superior SNRs and depth detetivity. However, by increasing the laser power and decreasing the chirp duration within the safety limits, the SNR and depth detectivity of the FD-PA method are enhanced considerably. The main cause to achieve lower experimental SNRs than theoretical predictions for pulsed PA response was shown to be the oscillating baseline, which can be partially eliminated by filtering.
12

Photoacoustic Imaging Using Chirp Technique: Comparison with Pulsed Laser Photoacoustics

Lashkari, Bahman 10 January 2012 (has links)
The application of photoacoustic (PA) phenomena to medical imaging has been investigated for more than a decade. To implement this modality, one may choose between two types of laser sources, pulsed or continuous wave (CW). This selection affects all features of the imaging technique. Nowadays pulsed lasers are the state-of-the-art technique in the PA research. In this work, various features of the alternative frequency-domain (FD) PA were investigated. An axially symmetric transfer function model of PA wave generation and a Krimholtz-Leedom-Matthaei (KLM) transducer model were developed and used to analyze the experimental results. The controllable parameters of the FD-PA were optimized to improve the signal-to-noise ratio (SNR), contrast, axial resolution and depth detectivity. For example, it was shown that employing the optimal chirp bandwidth can enhance the SNR by more than 10 dB. In addition to the image produced by the cross-correlation amplitude, the phase of the correlation signal was used as a separate channel. A statistical method was introduced to generate an image from this phase channel, and also to filter the PA amplitude channel. A study was also performed to compare FD PA and the prevalent pulsed method. Various features of both methods were examined experimentally using a dual-mode PA system and under the condition of maximum permissible exposure (MPE). The SNRs of both methods were evaluated theoretically and experimentally. It was shown that at low frequencies, both modalities generate comparable SNRs, and at high frequencies pulsed PA produces superior SNRs and depth detetivity. However, by increasing the laser power and decreasing the chirp duration within the safety limits, the SNR and depth detectivity of the FD-PA method are enhanced considerably. The main cause to achieve lower experimental SNRs than theoretical predictions for pulsed PA response was shown to be the oscillating baseline, which can be partially eliminated by filtering.
13

Turbine-Mounted Lidar:The pulsed lidar as a reliable alternative.

Braña, Isaac January 2011 (has links)
Expectations for turbine-mounted lidar are increasing. The installation of lidars in wind turbine nacelles for measuring incoming winds, preventing wind gusts and increasing energy productions is after recently studies, technically and economically feasible. Among available lidar types, the most studied were continuous wave lidars because they were the most reliable apparatus when this initiative began. However, after studying technical considerations and checking commercial lidars, it was found that pulsed lidarslead this technology due to their promising results. The purpose of this report is to fill the gap between the interest in this technology and the absence of any academic papers that analyzes continuous-wave and pulsed lidars forthe mounted lidar concept. Hence, this report discusses the importance of turbine mounted lidars for wind power industry, different possible configurations and explains why specifically pulsed lidars are becoming more important for the mounted lidarmarket.
14

Experimental investigations of two-phase flow measurement using ultrasonic sensors

Abbagoni, Baba Musa January 2016 (has links)
This thesis presents the investigations conducted in the use of ultrasonic technology to measure two-phase flow in both horizontal and vertical pipe flows which is important for the petroleum industry. However, there are still key challenges to measure parameters of the multiphase flow accurately. Four methods of ultrasonic technologies were explored. The Hilbert-Huang transform (HHT) was first applied to the ultrasound signals of air-water flow on horizontal flow for measurement of the parameters of the two- phase slug flow. The use of the HHT technique is sensitive enough to detect the hydrodynamics of the slug flow. The results of the experiments are compared with correlations in the literature and are in good agreement. Next, experimental data of air-water two-phase flow under slug, elongated bubble, stratified-wavy and stratified flow regimes were used to develop an objective flow regime classification of two-phase flow using the ultrasonic Doppler sensor and artificial neural network (ANN). The classifications using the power spectral density (PSD) and discrete wavelet transform (DWT) features have accuracies of 87% and 95.6% respectively. This is considerably more promising as it uses non-invasive and non-radioactive sensors. Moreover, ultrasonic pulse wave transducers with centre frequencies of 1MHz and 7.5MHz were used to measure two-phase flow both in horizontal and vertical flow pipes. The liquid level measurement was compared with the conductivity probes technique and agreed qualitatively. However, in the vertical with a gas volume fraction (GVF) higher than 20%, the ultrasound signals were attenuated. Furthermore, gas-liquid and oil-water two-phase flow rates in a vertical upward flow were measured using a combination of an ultrasound Doppler sensor and gamma densitometer. The results showed that the flow gas and liquid flow rates measured are within ±10% for low void fraction tests, water-cut measurements are within ±10%, densities within ±5%, and void fractions within ±10%. These findings are good results for a relatively fast flowing multiphase flow.
15

Exploration into the Use of a Software Defined Radio as a Low-Cost Radar Front-End

Monk, Andrew Michael 23 November 2020 (has links)
Inspection methods for satellites post-launch are currently expensive and/or dangerous. To address this, BYU, in conjunction with NASA, is designing a series of small satellites called CubeSATs. These small satellites are designed to be launched from a satellite and to visually inspect the launching body. The current satellite revision passively tumbles through space and is appropriately named the passive inspection cube satellite (PICS). The next revision actively maintains translation and rotation relative to the launching satellite and is named the translation, rotation inspection cube satellite (TRICS). One of the necessary sensors aboard this next revision is the means to detect distance. This work explores the feasibility of using a software defined radio as a small, low-cost front end for a ranging radar to fulfill this need. For this work, the LimeSDR-Mini is selected due to its low-cost, small form factor, full duplex operation, and open-source hardware/software. Additionally, due to the the channel characteristics of space, the linear frequency modulated continuous-wave (LFMCW) radar is selected as the radar architecture due to its ranging capabilities and simplicity. The LFMCW radar theory and simulation are presented. Two programming methods for the LimeSDR-Mini are considered: GNU Radio Companion and the pyLMS7002Soapy API. GNU Radio Companion is used for initial exploration of the LimeSDR-Mini and confirms its data streaming (RX and TX) and full duplex capabilities. The pyLMS7002Soapy API demonstrates further refined control over the LimeSDR-Mini while providing platform independence and deployability. This work concludes that the LimeSDR-Mini is capable of acting as the front end for a ranging radar aboard a small satellite provided the pyLMS7002Soapy API is used for configuration and control. GNU Radio Companion is not recommended as a programming platform for the LimeSDR-Mini and the pyLMS7002Soapy API requires further research to fine tune the SDR's performance.
16

A Platform for False Data Injection in Frequency Modulated Continuous Wave Radar

Chauhan, Ruchir 01 May 2014 (has links)
Radar is an acronym for RAdio Detection And Ranging. In general terms, it is a machine that uses radio waves for object-detection in its near periphery. It transmits radio waves in a known direction, which when intercepted by an obstruction/object are reflected by its surface and are received back at the radar system. The round trip delay time along with the known velocity of radio waves gives an accurate measurement of the distance of the object from the radar system. In a somewhat similar fashion, some radars are even capable of measuring the velocity of this object. Frequency-modulated continuous-wave (FMCW) radar is one such radar system, which is a subclass of continuous wave (CW) radars, where a continuous sinusoidal radio energy is transmitted, reflected, and received back at the radar system. These radar systems are widely used in vehicle automation technologies such as adaptive cruise control (ACC) and collision avoidance systems (CAS) to measure the distance from the nearest vehicles and maintain a safe following distance. But in designing these systems, little attention has been given to security, and these systems have vulnerabilities that are capable of compromising the whole purpose of making such systems. In this work one such vulnerability in FMCW radar was exploited to design an attack that was capable of decreasing the apparent distance, as measured by a radar system. The attack was designed in such a way that there was no tampering with the radar system being attacked. Instead, false distance information was introduced in the return path of the transmitted radio wave by absorbing the original victim transmission and sending out a modified radio wave on the It was shown that the distance could be decreased to alarming values, which at the level of the vehicle automation system results in decreasing the speed of the automobile when actually it should have increased.
17

BYU micro-SAR: A very small, low-power LFM-CW Synthetic Aperture Radar

Duersch, Michael Israel 03 December 2004 (has links) (PDF)
Brigham Young University has developed a low-cost, light-weight, and low power consumption SAR for flight on a small unmanned aerial vehicle (UAV) at low altitudes. This micro-SAR, or uSAR, consumes only 18 watts of power, ideal for application on a small UAV. To meet these constraints, a linear frequency modulation-continuous wave (LFM-CW) transmit signal is utilized. Use of an LFM-CW signal introduces some differences from the typical strip map SAR processing model that must be addressed in signal processing algorithms. This thesis presents a derivation of the LFM-CW signal model and the associated image processing algorithms used for the uSAR developed at BYU. A data simulator for the BYU LFM-CW SAR is detailed and results are provided for the case when the simulated data are processed using the uSAR algorithms. Data processing schemes are discussed, including compression, receive signal phase detection, interference filtering and auto-focusing. Finally, data collected from the instrument itself are processed and presented.
18

Residential Microwave Oven Interference on Bluetooth Data Performance

D'Souza, Mark Francis 19 May 2003 (has links)
This thesis investigates the interference potential of microwave ovens to Bluetooth data communication. Interference experiments are conducted in the CWT's Bluetooth lab, using CSR™ (Cambridge Silicone Radio) Bluetooth radios and a Tektronics™ Protocol Analyzer to record packet transmissions between the master and slave units. A novel, "quasi-real time" spectral measurement concept is developed to take radio frequency measurements. A LabView program enables a spectrum analyzer to download oven spectral data onto a computer via the instrument's serial port. From this data, three-dimensional plots of microwave radiated power levels versus ISM band frequencies over time periods are produced for different microwave ovens. These plots are compared with the results of interference experiments to explain Bluetooth packet errors. In addition to causing packet errors, emitted oven power levels at certain frequencies are sometimes strong enough to cause data packets to be lost (dropped) as they are transmitted over the air. This is a major problem since the Protocol Analyzer does not "see" these packets and cannot record the transmissions during an experiment. These lost packets can be accounted for if the frequency hopping scheme of the communicating Bluetooth devices is know prior to data transmission. Bluetooth's Frequency Hop Scheme is coded in Matlab for the purpose of predicting a data transmission's hopping sequence. The lost packets on each Bluetooth channel are counted by subtracting the Analyzer's recorded number of data transmissions per channel from the total number of transmissions per channel predicted by Matlab. A method is devised to calibrate the Bluetooth receiver and the spectrum analyzer is used to measure the received power level of Bluetooth signals on a particular frequency (channel). The number of packet errors on a channel is determined from the channel's C/I (carrier-to-interference ratio). If a channel's C/I level falls below the calculated C/I threshold at any instant of time due to oven operation, the packet transmitted at that instant is likely in error. A Matlab program estimates the number of packet errors per channel by counting the number of times the C/I of a channel falls below it's threshold value. The predicted number of packet errors is compared with the measured packet errors from experiments to yield extremely good results. Various oven-interference experiments are conducted in a small building, a large office environment and outdoors. For each experiment, the number of occurrences of transmitted data is plotted for each Bluetooth channel. Composite Excel bar graphs, created from this data, are compared with the oven spectral plots to describe an oven's effect on Bluetooth transmission. It is determined that different ovens cause packet errors on specifically different channels, in addition to channels 52-54 around the oven's 2450 MHz center operating frequency. The interference experiments suggest that placing an oven a radius of 10 m away from Class I (devices in a piconet will not affect data transmission). / Master of Science
19

Precessão Livre no Estado Estacionário com alternância de fase para RMN em alta e baixa resolução / Steady state free precession with phase alternation for NMR in high and low resolution.

Moraes, Tiago Bueno de 19 May 2016 (has links)
A aplicação de uma sequência de pulsos com tempo de repetição muito menor que os tempos de relaxação Tp << T2; T1, faz com que a magnetização atinja um estado estacionário descrito por H.Y. Carr como Estado Estacionário em Precessão Livre, Steady State Free Precession (SSFP). Nessa condição, o sinal é composto pela complexa sobreposição das componentes FID e eco. Sequências tipo SSFP são utilizadas na aquisição rápida de sinais, resultando em uma boa razão sinal ruído (s/r) em curto intervalo de tempo, porém introduzem fortes anomalias de fase e amplitude devido a complexa interação das componentes que formam o estado estacionário. Neste trabalho, desenvolvemos sequências de pulsos tipo SSFP para RMN em alta e baixa resolução com alternância e incremento de fase. Em alta resolução desenvolvemos as sequências SSFPdx e SSFPdxdt com incremento de fase linear e quadrático respectivamente. Os resultados mostram que espectros de núcleos com baixa sensibilidade podem ser obtidos com mesma razão s/r em menor tempo experimental e as sequências desenvolvidas removem as anomalias espectrais. Em baixa resolução, os resultados mostram que a introdução de alternâncias de fase na Continuous Wave Free Precession (CWFP) possibilita a remoção da dependência da sequência com o offset de frequência e com o tempo entre pulsos. Além disso, mostramos que a sequência CP-CWFPx-x com ângulo de refocalização pequeno (5&deg; a 10&deg;) possibilita a estimativa rápida do tempos de relaxação longitudinal. Apresentamos também resultados dos estudos e desenvolvidos no estágio de pesquisa no exterior, onde as sequências de pulsos no estado estacionário &ndash; DECPMG e Split 180&deg; &ndash; foram estudas numericamente e implementadas nos sistemas magnéticos compactos: mini-Halbach e MOUSE-NMR. Por fim, são apresentados resultados com os métodos de processamento de dados Krylov Basis Diagonalization Method (KBDM) e a Transformada Inversa de Laplace aplicados na análise de sinais SSFP. Resultados mostram que KBDM é uma ferramenta útil no processamento de dados em alta e baixa resolução, tanto na obtenção de espectros como na determinação da distribuição dos tempos de relaxação. / The application of a pulse sequence with repetition time much smaller than the relaxation times, Tp << T2; T1, causes the magnetization to reach a steady state, described by H. Y. Carr as a Steady State Free Precession (SSFP). In this condition, the signal is composed of the complex overlapping of the FID and eco components. SSFP type sequences are used in fast acquisition of NMR signals, resulting in a good signal to noise ratio (s/r) in a short time interval, however, they introduce phase and amplitude anomalies due to the complex interaction between the components of the steady state. In this work, we develop SSFP type pulse sequences for NMR in high and low resolution, with alternation and increment of phase. In high resolution, we develop SSFPdx and SSFPdxdt sequences, with linear and quadratic phase increment respectively. Results show that the low sensitivity nuclei spectra can be obtained with the same s/r ratio in smaller experimental time, about an order of magnitude, and the developed sequences can remove the spectral anomalies. In low resolution, the results show that the introduction of a phase alternation in the Continuous Wave Free Precession (CWFP) allows the elimination of the dependence of the sequence with the offset frequency and the time between pulses. Besides, we show that the CP-CWFPx-x sequence with a small refocalization angle (5° to 10°) allows the fast estimative of the longitudinal relaxation time in a single experiment. The results of the studies conducted during an international research internship are also presented. Steady state pulse sequences &ndash; DECPMG and Split 180° &ndash; were studied and implemented in compact magnetic systems: mini-Halbach and MOUSE-NMR. Finally, the results of the application of the Krylov Basis Diagonalization Method (KBDM) and the Inverse Laplace Transform for the analysis of SSFP signals are presented. The results show that KBDM is a useful tool in data processing for low and high resolution, both for obtaining spectra and determining the relaxation times distribution.
20

Precessão Livre no Estado Estacionário com alternância de fase para RMN em alta e baixa resolução / Steady state free precession with phase alternation for NMR in high and low resolution.

Tiago Bueno de Moraes 19 May 2016 (has links)
A aplicação de uma sequência de pulsos com tempo de repetição muito menor que os tempos de relaxação Tp << T2; T1, faz com que a magnetização atinja um estado estacionário descrito por H.Y. Carr como Estado Estacionário em Precessão Livre, Steady State Free Precession (SSFP). Nessa condição, o sinal é composto pela complexa sobreposição das componentes FID e eco. Sequências tipo SSFP são utilizadas na aquisição rápida de sinais, resultando em uma boa razão sinal ruído (s/r) em curto intervalo de tempo, porém introduzem fortes anomalias de fase e amplitude devido a complexa interação das componentes que formam o estado estacionário. Neste trabalho, desenvolvemos sequências de pulsos tipo SSFP para RMN em alta e baixa resolução com alternância e incremento de fase. Em alta resolução desenvolvemos as sequências SSFPdx e SSFPdxdt com incremento de fase linear e quadrático respectivamente. Os resultados mostram que espectros de núcleos com baixa sensibilidade podem ser obtidos com mesma razão s/r em menor tempo experimental e as sequências desenvolvidas removem as anomalias espectrais. Em baixa resolução, os resultados mostram que a introdução de alternâncias de fase na Continuous Wave Free Precession (CWFP) possibilita a remoção da dependência da sequência com o offset de frequência e com o tempo entre pulsos. Além disso, mostramos que a sequência CP-CWFPx-x com ângulo de refocalização pequeno (5&deg; a 10&deg;) possibilita a estimativa rápida do tempos de relaxação longitudinal. Apresentamos também resultados dos estudos e desenvolvidos no estágio de pesquisa no exterior, onde as sequências de pulsos no estado estacionário &ndash; DECPMG e Split 180&deg; &ndash; foram estudas numericamente e implementadas nos sistemas magnéticos compactos: mini-Halbach e MOUSE-NMR. Por fim, são apresentados resultados com os métodos de processamento de dados Krylov Basis Diagonalization Method (KBDM) e a Transformada Inversa de Laplace aplicados na análise de sinais SSFP. Resultados mostram que KBDM é uma ferramenta útil no processamento de dados em alta e baixa resolução, tanto na obtenção de espectros como na determinação da distribuição dos tempos de relaxação. / The application of a pulse sequence with repetition time much smaller than the relaxation times, Tp << T2; T1, causes the magnetization to reach a steady state, described by H. Y. Carr as a Steady State Free Precession (SSFP). In this condition, the signal is composed of the complex overlapping of the FID and eco components. SSFP type sequences are used in fast acquisition of NMR signals, resulting in a good signal to noise ratio (s/r) in a short time interval, however, they introduce phase and amplitude anomalies due to the complex interaction between the components of the steady state. In this work, we develop SSFP type pulse sequences for NMR in high and low resolution, with alternation and increment of phase. In high resolution, we develop SSFPdx and SSFPdxdt sequences, with linear and quadratic phase increment respectively. Results show that the low sensitivity nuclei spectra can be obtained with the same s/r ratio in smaller experimental time, about an order of magnitude, and the developed sequences can remove the spectral anomalies. In low resolution, the results show that the introduction of a phase alternation in the Continuous Wave Free Precession (CWFP) allows the elimination of the dependence of the sequence with the offset frequency and the time between pulses. Besides, we show that the CP-CWFPx-x sequence with a small refocalization angle (5° to 10°) allows the fast estimative of the longitudinal relaxation time in a single experiment. The results of the studies conducted during an international research internship are also presented. Steady state pulse sequences &ndash; DECPMG and Split 180° &ndash; were studied and implemented in compact magnetic systems: mini-Halbach and MOUSE-NMR. Finally, the results of the application of the Krylov Basis Diagonalization Method (KBDM) and the Inverse Laplace Transform for the analysis of SSFP signals are presented. The results show that KBDM is a useful tool in data processing for low and high resolution, both for obtaining spectra and determining the relaxation times distribution.

Page generated in 0.096 seconds