• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 68
  • 38
  • 6
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 136
  • 136
  • 67
  • 43
  • 43
  • 41
  • 31
  • 28
  • 19
  • 15
  • 14
  • 13
  • 13
  • 13
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Exploring the potential of protein cages as MRI contrast agents with an emphasis on protein cage characterization by mass spectrometry techniques

Liepold, Lars Otto. January 2009 (has links) (PDF)
Thesis (PhD)--Montana State University--Bozeman, 2009. / Typescript. Chairperson, Graduate Committee: Trevor Douglas. Includes bibliographical references (leaves 127-140).
62

Superparamagnetic nanoparticles for cancer diagnostics and therapeutics /

Kohler, Nathan. January 2005 (has links)
Thesis (Ph. D.)--University of Washington, 2005. / Vita. Includes bibliographical references (leaves 205-218).
63

Neurotoxicidade comparativa do iobitridol com o iohexol por via intracisternal em ratos wistar

Mello, Fabíola Peixoto da Silva January 2011 (has links)
Os meios de contraste iodados são substâncias radiopacas utilizadas em mielografias e, muito embora o iohexol e o iopamidol sejam considerados seguros na rotina mielográfica de humanos e animais, eventos adversos são relacionados ao seu uso. O iobitridol foi desenvolvido mais recentemente, sendo seu desenho molecular obtido após pesquisas sobre a conformação, distribuição e natureza permanente da estrutura hidrofílica; no entanto, estudos referentes à neurotoxicidade do iobitridol com administração subaracnóide são escassos e inconclusivos. O objetivo do presente trabalho foi comparar a neurotoxicidade do iobitridol com a do iohexol, por via intracisternal em ratos Wistar, como avaliação pré-clínica da utilização deste como agente mielográfico. Foram utilizados 75 animais divididos em três grupos experimentais de 25 animais: iobitridol, iohexol e NaCl 0,9% (grupo controle), e; estes subdivididos em cinco subgrupos com cinco animais cada, com doses distintas de 200, 400, 600, 800 e 1000 mg I/kg, sendo utilizado no grupo controle o volume equivalente aos meios de contraste testados. Os animais foram avaliados no momento da aplicação do iohexol e iobitridol quanto a alterações do trato respiratório, e posteriormente, aos 5, 15, 30, 60, 120, 180 e 240 minutos após este procedimento, quanto a sinais de depressão e excitação, reflexos tátil de agarramento palmar, flexor, extensor, palpebral, pupilar e da pina, reação de endireitamento e posicionamento e resposta auditiva. Nos sete dias subseqüentes, foram avaliados diariamente quanto a estes parâmetros, e ainda mensurados o peso e a ingestão de ração e de água. Não foram observadas diferenças estatisticamente significativas entre os grupos testados com meios de contraste, em nenhum dos parâmetros avaliados. Nesse modelo animal o iobitridol demonstrou baixa neurotoxicidade, comparável a observada com o iohexol, tornando-o uma possibilidade alternativa para utilização pela via subaracnóidea para realização de mielografias. / The iodinated contrast agents are radiopaque substances used in myelography, and although the iohexol and iopamidol are considered safe in human and animal myelographic routine, adverse events are related to their use. The iobitridol was recently developed, and its molecular designs obtained after research on the configuration, distribution and permanent nature of hydrophilic structure; however, neurotoxicologic studies of iobitridol in subarachnoid administration are scarce and inconclusive. The purpose of this study was to compare the neurotoxicity of iobitridol with iohexol, by intracisternal administration in Wistar rats, as pre-clinical evaluation of the use of this substance as myelographic agent. Seventy five animals were used, divided into three experimental groups with twenty five animals: iobitridol, iohexol and NaCl 0,9% (control group); and they are divided into five subgroups of five animals each, with different doses of 200, 400, 600, 800 and 1000 mg I/kg, while the control group received the equivalent volume of contrast media tested. The animals were evaluated during injection of iohexol and iobitridol on changes of respiratory tract, and subsequently at 5, 15, 30, 60, 120, 180 and 240 minutes after this procedure, for signs of depression and excitement, tactile palmar grasp, flexor, extensor, palpebral, papillary and pinna reflexes, surface righting and placing reactions, and auditory startle test. The evaluations were assessed daily for seven days these parameters, and the body weight and food and water intake were also measured. There were no statistically significant differences between groups tested with respect to any of the evaluated parameters, in other words, in this animal model, the iobitridol demonstred low neurotoxicologic potential, comparable to the observed with iohexol. In conclusion, iobitridol should be a safe alternative to myelography.
64

Análise da penetrabilidade de duas substâncias irrigadoras: estudo em canais simulados / Analysis of penetration two irrigating solutions: a study in simulated canals

Marcus Vinicius Corvelo de Andrade 27 September 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo do estudo foi verificar ex vivo a penetração de duas substâncias irrigantes hipoclorito de sódio 5% e Chlor-Xtra (Vista Dental Products, Racine, WI) através da adição de corante em canais simulados de dentes clarificados. Sessenta caninos inferiores unirradiculares humanos foram utilizados. As raízes foram seccionados em 16mm e instrumentadas com limas rotatórias do sistema Protaper até a F2 no comprimento de trabalho de 15mm. As amostras foram submetidas ao processo de clarificação para ficarem transparentes e durante o processo foram criados os canais simulados no terço apical. As raízes foram divididas aleatoriamente em três grupos ( NaOCl 5%, Chlor-Xtra e água) contendo 20 espécime por grupo. As amostras foram irrigadas com 1,5mL de solução contraste( tinta chinesa junto com a solução irrigante do respectivo grupo). E cada amostra foi fotografada e analisada. Os dados foram analisados estatisticamente pelos testes Kruskal-Wallis e Student-Neuman-Keuls. Não houve diferença estatística entre as substâncias irrigantes testadas (p>0,05). A partir da análise dos dados, foi possível concluir que apesar da presença de agentes surfactantes na solução irrigante de Chlor-Xtra não houve uma melhor penetrabilidade nos canais simulados em comparação ao hipoclorito de sódio(NaOCl). / The aim of this work was to asses ex vivo penetration of two irrigation substances sodium hypochlorite 5% and Chlor-Xtra (Vista Dental Products, Racine, WI) by the addition of dye in simulated canals from cleared teeth. Sixty single-rooted human mandibular canines were used. Roots length was standardized to 16 mm and root canal shaping was performed to a working length of 15 mm using Protaper Universal rotary files (Maillefer) up to F2 corresponding to a 25/.08 size/taper. The samples were cleared using clearing technique and and simulated canals were created in apical third at the time of process. Roots were randomly divided into three groups (5% NaOCl, Chlor-Xtra and water) containing 20 specimens per group. Samples were irrigated with 1.5 mL of contrast solution (Chinese ink and irrigating substance of the group). And each sample was photographed and analyzed. Data were statistically analyzed by Kruskal-Wallis and Student-Neuman-Keuls tests. No statistical difference between the tested irrigating solutions was found (p> 0.05). From the data analysis, we conclude that in despite of the presence of surfactants in the irrigating solution Chlor-Xtra did not result better penetration into simulated canals than sodium hypochlorite (NaOCl).
65

Neurotoxicidade comparativa do iobitridol com o iohexol por via intracisternal em ratos wistar

Mello, Fabíola Peixoto da Silva January 2011 (has links)
Os meios de contraste iodados são substâncias radiopacas utilizadas em mielografias e, muito embora o iohexol e o iopamidol sejam considerados seguros na rotina mielográfica de humanos e animais, eventos adversos são relacionados ao seu uso. O iobitridol foi desenvolvido mais recentemente, sendo seu desenho molecular obtido após pesquisas sobre a conformação, distribuição e natureza permanente da estrutura hidrofílica; no entanto, estudos referentes à neurotoxicidade do iobitridol com administração subaracnóide são escassos e inconclusivos. O objetivo do presente trabalho foi comparar a neurotoxicidade do iobitridol com a do iohexol, por via intracisternal em ratos Wistar, como avaliação pré-clínica da utilização deste como agente mielográfico. Foram utilizados 75 animais divididos em três grupos experimentais de 25 animais: iobitridol, iohexol e NaCl 0,9% (grupo controle), e; estes subdivididos em cinco subgrupos com cinco animais cada, com doses distintas de 200, 400, 600, 800 e 1000 mg I/kg, sendo utilizado no grupo controle o volume equivalente aos meios de contraste testados. Os animais foram avaliados no momento da aplicação do iohexol e iobitridol quanto a alterações do trato respiratório, e posteriormente, aos 5, 15, 30, 60, 120, 180 e 240 minutos após este procedimento, quanto a sinais de depressão e excitação, reflexos tátil de agarramento palmar, flexor, extensor, palpebral, pupilar e da pina, reação de endireitamento e posicionamento e resposta auditiva. Nos sete dias subseqüentes, foram avaliados diariamente quanto a estes parâmetros, e ainda mensurados o peso e a ingestão de ração e de água. Não foram observadas diferenças estatisticamente significativas entre os grupos testados com meios de contraste, em nenhum dos parâmetros avaliados. Nesse modelo animal o iobitridol demonstrou baixa neurotoxicidade, comparável a observada com o iohexol, tornando-o uma possibilidade alternativa para utilização pela via subaracnóidea para realização de mielografias. / The iodinated contrast agents are radiopaque substances used in myelography, and although the iohexol and iopamidol are considered safe in human and animal myelographic routine, adverse events are related to their use. The iobitridol was recently developed, and its molecular designs obtained after research on the configuration, distribution and permanent nature of hydrophilic structure; however, neurotoxicologic studies of iobitridol in subarachnoid administration are scarce and inconclusive. The purpose of this study was to compare the neurotoxicity of iobitridol with iohexol, by intracisternal administration in Wistar rats, as pre-clinical evaluation of the use of this substance as myelographic agent. Seventy five animals were used, divided into three experimental groups with twenty five animals: iobitridol, iohexol and NaCl 0,9% (control group); and they are divided into five subgroups of five animals each, with different doses of 200, 400, 600, 800 and 1000 mg I/kg, while the control group received the equivalent volume of contrast media tested. The animals were evaluated during injection of iohexol and iobitridol on changes of respiratory tract, and subsequently at 5, 15, 30, 60, 120, 180 and 240 minutes after this procedure, for signs of depression and excitement, tactile palmar grasp, flexor, extensor, palpebral, papillary and pinna reflexes, surface righting and placing reactions, and auditory startle test. The evaluations were assessed daily for seven days these parameters, and the body weight and food and water intake were also measured. There were no statistically significant differences between groups tested with respect to any of the evaluated parameters, in other words, in this animal model, the iobitridol demonstred low neurotoxicologic potential, comparable to the observed with iohexol. In conclusion, iobitridol should be a safe alternative to myelography.
66

Avaliação das reações adversas agudas após administração endovenosa de contraste iodado iônico e não-iônico em hospital oncológico

Cremonini, Camila do Carmo Rodrigues [UNESP] 02 March 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-03-02Bitstream added on 2014-06-13T20:29:55Z : No. of bitstreams: 1 cremonini_ccr_me_botfm.pdf: 1144679 bytes, checksum: bf9c1e1e39c197477cae8519b0e360ce (MD5) / Fundação Pio Xii - Barretos / Avaliar a ocorrência e a gravidade das reações adversas agudas (RAA) com o uso do meio de contraste iodado iônico e não-iônico nos pacientes submetidos ao exame de tomografia computadorizada (TC) em hospital nacional terciário oncológico e avaliar neoplasia como possível risco para RAA. Secundariamente, avaliar o impacto do uso seletivo do meio de contraste iodado nos custos. Pacientes submetidos à TC com contraste iodado entre outubro de 2007 e agosto de 2008 foram avaliados quanto à ocorrência e à gravidade das reações adversas agudas aos meios de contrastes iônicos e nãoiônicos. As reações foram categorizadas em leve, moderada ou grave de acordo com o tipo dos sinais e sintomas e classificadas como agudas pelo tempo de ocorrência, desde o momento da injeção até 30 minutos após. Os testes do quiquadrado e exato de Fisher foram utilizados para análise estatística da ocorrência de RAA em relação às variáveis de gênero e idade. O estudo foi aprovado pelo Comitê de Ética local e o Termo de Consentimento Livre Esclarecido foi obtido. Houve 78 RAA ao contraste iodado iônico e 11 ao não-iônico, com uma ocorrência global de 3,3% (78/2.339) e 0,5% (11/2.216), respectivamente. A maioria das reações foi classificada como leve em ambos os grupos, representando 91% (71) no grupo iônico e 81,8% (9) no grupo não-iônico. As demais reações foram do tipo moderada não havendo nenhuma reação grave. Em relação ao início das RAA, 71% e 73% (iônico e não-iônico) ocorreram nos primeiros 5 minutos. A freqüência de RAA no grupo em que recebeu contraste iônico foi maior no sexo feminino (p < 0,001). No grupo não-iônico não houve diferença estatisticamente significativa entre os sexos (p = 1,0). Não houve associação entre a presença de reação aguda e as faixas... / To evaluate the occurrence and severity of acute adverse reactions (AAR) to iodinated ionic and non-ionic contrast media in patients undergoing computerized tomography (CT) at a national tertiary cancer hospital and to evaluate neoplasm as a possible risk for AAR. Secondly, to assess the impact of selective use of iodinated contrast agent costs. Patients who underwent contrast-enhanced CT between October 2007 and August 2008 were evaluated for the presence and severity of acute adverse reactions to ionic and non-ionic contrast media. The reactions were categorized as mild, moderate or severe according to the type of signs and symptoms and classified as acute by the time of occurrence, from the time of the injection up to 30 minutes afterwards. The chi-square and Fisher’s exact were used for statistical analysis of the occurrence of AAR for the variables of gender and age. The study was approved by the local Ethics Committee and informed consent was obtained. There were 78 AAR to ionic iodinated contrast and 11 to non-ionic, with an overall occurrence of 3.3% (78/2339) and 0.5% (11/2216), respectively. Most reactions were classified as mild in both groups, representing 91% (71) in the ionic group and 81.8% (9) in the non-ionic group. All other reactions were moderate and there were no severe reactions. Regarding onset of AAR, 71% and 73% (ionic and non-ionic group) occurred in the first five minutes. The occurrence of AAR in the group who received ionic contrast was higher in females (p <0.001). As for the non-ionic group, there was no significant statistical difference between genders (p = 1.0). There was no association between the presence of acute reaction and the age groups of the population in the ionic contrast group. For the non-ionic group, no statistical analysis was performed as the sample was deemed reduced. Among... (Complete abstract click electronic access below)
67

Avaliação das reações adversas agudas após administração endovenosa de contraste iodado iônico e não-iônico em hospital oncológico /

Cremonini, Camila do Carmo Rodrigues. January 2010 (has links)
Orientador: Euclides Timótio da Rocha / Banca: Fabiano Rubião Lucchesi / Banca: Jorge Elias Junior / Resumo: Avaliar a ocorrência e a gravidade das reações adversas agudas (RAA) com o uso do meio de contraste iodado iônico e não-iônico nos pacientes submetidos ao exame de tomografia computadorizada (TC) em hospital nacional terciário oncológico e avaliar neoplasia como possível risco para RAA. Secundariamente, avaliar o impacto do uso seletivo do meio de contraste iodado nos custos. Pacientes submetidos à TC com contraste iodado entre outubro de 2007 e agosto de 2008 foram avaliados quanto à ocorrência e à gravidade das reações adversas agudas aos meios de contrastes iônicos e nãoiônicos. As reações foram categorizadas em leve, moderada ou grave de acordo com o tipo dos sinais e sintomas e classificadas como agudas pelo tempo de ocorrência, desde o momento da injeção até 30 minutos após. Os testes do quiquadrado e exato de Fisher foram utilizados para análise estatística da ocorrência de RAA em relação às variáveis de gênero e idade. O estudo foi aprovado pelo Comitê de Ética local e o Termo de Consentimento Livre Esclarecido foi obtido. Houve 78 RAA ao contraste iodado iônico e 11 ao não-iônico, com uma ocorrência global de 3,3% (78/2.339) e 0,5% (11/2.216), respectivamente. A maioria das reações foi classificada como leve em ambos os grupos, representando 91% (71) no grupo iônico e 81,8% (9) no grupo não-iônico. As demais reações foram do tipo moderada não havendo nenhuma reação grave. Em relação ao início das RAA, 71% e 73% (iônico e não-iônico) ocorreram nos primeiros 5 minutos. A freqüência de RAA no grupo em que recebeu contraste iônico foi maior no sexo feminino (p < 0,001). No grupo não-iônico não houve diferença estatisticamente significativa entre os sexos (p = 1,0). Não houve associação entre a presença de reação aguda e as faixas... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: To evaluate the occurrence and severity of acute adverse reactions (AAR) to iodinated ionic and non-ionic contrast media in patients undergoing computerized tomography (CT) at a national tertiary cancer hospital and to evaluate neoplasm as a possible risk for AAR. Secondly, to assess the impact of selective use of iodinated contrast agent costs. Patients who underwent contrast-enhanced CT between October 2007 and August 2008 were evaluated for the presence and severity of acute adverse reactions to ionic and non-ionic contrast media. The reactions were categorized as mild, moderate or severe according to the type of signs and symptoms and classified as acute by the time of occurrence, from the time of the injection up to 30 minutes afterwards. The chi-square and Fisher's exact were used for statistical analysis of the occurrence of AAR for the variables of gender and age. The study was approved by the local Ethics Committee and informed consent was obtained. There were 78 AAR to ionic iodinated contrast and 11 to non-ionic, with an overall occurrence of 3.3% (78/2339) and 0.5% (11/2216), respectively. Most reactions were classified as mild in both groups, representing 91% (71) in the ionic group and 81.8% (9) in the non-ionic group. All other reactions were moderate and there were no severe reactions. Regarding onset of AAR, 71% and 73% (ionic and non-ionic group) occurred in the first five minutes. The occurrence of AAR in the group who received ionic contrast was higher in females (p <0.001). As for the non-ionic group, there was no significant statistical difference between genders (p = 1.0). There was no association between the presence of acute reaction and the age groups of the population in the ionic contrast group. For the non-ionic group, no statistical analysis was performed as the sample was deemed reduced. Among... (Complete abstract click electronic access below) / Mestre
68

Análise da penetrabilidade de duas substâncias irrigadoras: estudo em canais simulados / Analysis of penetration two irrigating solutions: a study in simulated canals

Marcus Vinicius Corvelo de Andrade 27 September 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo do estudo foi verificar ex vivo a penetração de duas substâncias irrigantes hipoclorito de sódio 5% e Chlor-Xtra (Vista Dental Products, Racine, WI) através da adição de corante em canais simulados de dentes clarificados. Sessenta caninos inferiores unirradiculares humanos foram utilizados. As raízes foram seccionados em 16mm e instrumentadas com limas rotatórias do sistema Protaper até a F2 no comprimento de trabalho de 15mm. As amostras foram submetidas ao processo de clarificação para ficarem transparentes e durante o processo foram criados os canais simulados no terço apical. As raízes foram divididas aleatoriamente em três grupos ( NaOCl 5%, Chlor-Xtra e água) contendo 20 espécime por grupo. As amostras foram irrigadas com 1,5mL de solução contraste( tinta chinesa junto com a solução irrigante do respectivo grupo). E cada amostra foi fotografada e analisada. Os dados foram analisados estatisticamente pelos testes Kruskal-Wallis e Student-Neuman-Keuls. Não houve diferença estatística entre as substâncias irrigantes testadas (p>0,05). A partir da análise dos dados, foi possível concluir que apesar da presença de agentes surfactantes na solução irrigante de Chlor-Xtra não houve uma melhor penetrabilidade nos canais simulados em comparação ao hipoclorito de sódio(NaOCl). / The aim of this work was to asses ex vivo penetration of two irrigation substances sodium hypochlorite 5% and Chlor-Xtra (Vista Dental Products, Racine, WI) by the addition of dye in simulated canals from cleared teeth. Sixty single-rooted human mandibular canines were used. Roots length was standardized to 16 mm and root canal shaping was performed to a working length of 15 mm using Protaper Universal rotary files (Maillefer) up to F2 corresponding to a 25/.08 size/taper. The samples were cleared using clearing technique and and simulated canals were created in apical third at the time of process. Roots were randomly divided into three groups (5% NaOCl, Chlor-Xtra and water) containing 20 specimens per group. Samples were irrigated with 1.5 mL of contrast solution (Chinese ink and irrigating substance of the group). And each sample was photographed and analyzed. Data were statistically analyzed by Kruskal-Wallis and Student-Neuman-Keuls tests. No statistical difference between the tested irrigating solutions was found (p> 0.05). From the data analysis, we conclude that in despite of the presence of surfactants in the irrigating solution Chlor-Xtra did not result better penetration into simulated canals than sodium hypochlorite (NaOCl).
69

Neurotoxicidade comparativa do iobitridol com o iohexol por via intracisternal em ratos wistar

Mello, Fabíola Peixoto da Silva January 2011 (has links)
Os meios de contraste iodados são substâncias radiopacas utilizadas em mielografias e, muito embora o iohexol e o iopamidol sejam considerados seguros na rotina mielográfica de humanos e animais, eventos adversos são relacionados ao seu uso. O iobitridol foi desenvolvido mais recentemente, sendo seu desenho molecular obtido após pesquisas sobre a conformação, distribuição e natureza permanente da estrutura hidrofílica; no entanto, estudos referentes à neurotoxicidade do iobitridol com administração subaracnóide são escassos e inconclusivos. O objetivo do presente trabalho foi comparar a neurotoxicidade do iobitridol com a do iohexol, por via intracisternal em ratos Wistar, como avaliação pré-clínica da utilização deste como agente mielográfico. Foram utilizados 75 animais divididos em três grupos experimentais de 25 animais: iobitridol, iohexol e NaCl 0,9% (grupo controle), e; estes subdivididos em cinco subgrupos com cinco animais cada, com doses distintas de 200, 400, 600, 800 e 1000 mg I/kg, sendo utilizado no grupo controle o volume equivalente aos meios de contraste testados. Os animais foram avaliados no momento da aplicação do iohexol e iobitridol quanto a alterações do trato respiratório, e posteriormente, aos 5, 15, 30, 60, 120, 180 e 240 minutos após este procedimento, quanto a sinais de depressão e excitação, reflexos tátil de agarramento palmar, flexor, extensor, palpebral, pupilar e da pina, reação de endireitamento e posicionamento e resposta auditiva. Nos sete dias subseqüentes, foram avaliados diariamente quanto a estes parâmetros, e ainda mensurados o peso e a ingestão de ração e de água. Não foram observadas diferenças estatisticamente significativas entre os grupos testados com meios de contraste, em nenhum dos parâmetros avaliados. Nesse modelo animal o iobitridol demonstrou baixa neurotoxicidade, comparável a observada com o iohexol, tornando-o uma possibilidade alternativa para utilização pela via subaracnóidea para realização de mielografias. / The iodinated contrast agents are radiopaque substances used in myelography, and although the iohexol and iopamidol are considered safe in human and animal myelographic routine, adverse events are related to their use. The iobitridol was recently developed, and its molecular designs obtained after research on the configuration, distribution and permanent nature of hydrophilic structure; however, neurotoxicologic studies of iobitridol in subarachnoid administration are scarce and inconclusive. The purpose of this study was to compare the neurotoxicity of iobitridol with iohexol, by intracisternal administration in Wistar rats, as pre-clinical evaluation of the use of this substance as myelographic agent. Seventy five animals were used, divided into three experimental groups with twenty five animals: iobitridol, iohexol and NaCl 0,9% (control group); and they are divided into five subgroups of five animals each, with different doses of 200, 400, 600, 800 and 1000 mg I/kg, while the control group received the equivalent volume of contrast media tested. The animals were evaluated during injection of iohexol and iobitridol on changes of respiratory tract, and subsequently at 5, 15, 30, 60, 120, 180 and 240 minutes after this procedure, for signs of depression and excitement, tactile palmar grasp, flexor, extensor, palpebral, papillary and pinna reflexes, surface righting and placing reactions, and auditory startle test. The evaluations were assessed daily for seven days these parameters, and the body weight and food and water intake were also measured. There were no statistically significant differences between groups tested with respect to any of the evaluated parameters, in other words, in this animal model, the iobitridol demonstred low neurotoxicologic potential, comparable to the observed with iohexol. In conclusion, iobitridol should be a safe alternative to myelography.
70

Complementary imaging of solid breast lesions:contribution of ultrasonography, fine-needle aspiration biopsy, and high-field and low-field MR imaging

Reinikainen, H. (Heli) 06 June 2003 (has links)
Abstract This study aimed to assess the value of B-mode, nonenhanced and enhanced power Doppler ultrasonography (US), fine-needle aspiration biopsy (FNAB) and magnetic resonance (MR) imaging as adjunctive tools in breast diagnostics. The findings were compared to histology. The mammograms and US images of 84 palpable breast lesions were retrospectively reviewed, 63 of them also blindly. The cytologic reports of 57 lesions were reviewed. Eighty-one (96%) of all the 84 lesions, and 52 of the 53 cancers were visible as a local abnormality at US. The sensitivity, specificity, and overall accuracy of FNAB cytology was 92%, 83%, and 88%, respectively. There were no false negative malignancies in the three modalities combined. Sixty-five lesions not unequivocally benign at mammography were examined with B-mode, unenhanced and enhanced power Doppler US. Vascularity was also analyzed quantitatively. The sensitivity, specificity, and overall accuracy of the morphologic evaluation was 100%, 10%, and 57%, respectively. Rounded lesions were more vascular than spiculated lesions, but vascular assessment was only helpful when supporting a benign morphology. Forty breast lesions were examined with dynamic MR imaging and power Doppler US by obtaining time-signal intensity curves, which were analyzed morphologically and quantitatively. The shape of the MR curve acchieved 90% accuracy in differentiating between benign and malignant lesions. It enabled also differentiation between fibroadenomas and malignancies. The accuracy of the US curve was 38%. Quantitatively, statistically significant differences were found using all the MR variables, except between fibroadenomas and malignancies. Using the US variables, no significant difference was found. Twenty-eight patients (34 breasts) were examined by dynamic low-field and high-field MR imaging. The images were analyzed separately by two radiologists paying attention to lesion morphology and enhancement kinetics. In 27 breasts, results were compared to biopsy. Kappa statistics was used to compare the performance between the MR-scanners and readers. The sensitivity was 100% and 100%, the specificity 82% and 73%, and the accuracy 93% and 89% at low and high field, respectively. The inter-MR-scanner kappa value was 0.77 (substantial agreement), while the inter-observer kappa value was 0.86 and 0.81 at low and high field, respectively (almost perfect agreement).

Page generated in 0.0768 seconds