21

Adiabatic pulse preparation for imaging iron oxide nanoparticles

Harris, Steven Scott 26 January 2012 (has links)
Iron oxide nanoparticles are of great interest as contrast agents for research and potentially clinical molecular magnetic resonance imaging (MRI). Biochemically modifying the surface coatings of the particles with proteins and polysaccharides enhances their utility by improving cell receptor specificity, increasing uptake for cell labeling and adding therapeutic molecules. Together with the high contrast they produce in MR images, these characteristics promise an expanding role for iron oxide nanoparticles and molecular MR imaging for studying, diagnosing and treating diseases at the molecular level. However, these contrast agents produce areas of signal loss with traditional MRI sequences that are not specific to the nanoparticles and cannot easily quantify the contrast agent concentration. With the expanding role of iron oxide nanoparticles in molecular imaging, new methods are needed to produce a quantitative contrast that is specific to the iron oxide nanoparticle. This dissertation presents a new method for detecting and quantifying iron oxide nanoparticles using an adiabatic preparation pulse and the failure of the adiabatic condition for spins diffusing near the particles. In the first aim, the theoretical foundation of the work is presented, and a Monte Carlo simulation supporting the proposed mechanism of the contrast is described. Adiabatic pulse prepared imaging sequences are also developed for imaging at 3 Tesla and 9.4 Tesla to highlight the translational potential of the approach for clinical examinations and scientific research, and the linear correlation of the contrast with iron concentration ideal for quantification is presented. Further, the physical characteristics of the nanoparticles and the parameters of the MRI sequence are modified to characterize the approach. In the second aim, the contrast is characterized in more realistic phantoms and in vitro, and a method to more accurately quantify nanoparticle concentration in the presence of magnetization transfer is presented. Finally, accelerated imaging methods are implemented to acquire the adiabatic contrast in a time compatible with in vivo imaging, and the technique is evaluated in an in vivo model of quantitative iron oxide nanoparticle imaging. Together, these aims present a method using an adiabatic preparation pulse to generate an MR contrast based on the microscopic magnetic field gradients surrounding the iron oxide nanoparticles that is suitable for in vivo quantitative, molecular imaging.
22

Contrast-induced nephropathy in coronary angiography patients when using Ioversol and Iomeprol : a meta-analysis

Chipere, Tawanda Alfred Gilbert 06 1900 (has links)
Ioversol and Iomeprol are radiological contrast media commonly used interchangeably in many South African imaging facilities for coronary angiography. Despite differences in chemical composition, they are presumed to have similar renal safety profiles. However, no studies directly compare the renal safety of these two contrast media for coronary angiography in a predominantly healthy population. A systematic review was performed to establish which contrast medium is safer. Articles were sourced from Medline, CINAHL, Scopus, Science Direct, and PubMed Clinical Queries databases. Eligible studies were peer-reviewed articles of coronary angiography examinations carried out on a healthy adult population, where Ioversol or Iomeprol or both were administered, with contrast-induced nephropathy as an end-point. Six articles with a total population of 2431 patients were selected. The Cochrane Risk of Bias Tool was used in evaluating included articles. Pooling studies using the random effects model did not show a statistically significant reduction in contrast-induced nephropathy when Iomeprol was administered (Risk ratio 1.14, 95% confidence interval 0.797-1.643, p = 0.466). Moderate heterogeneity (I2=54.21%) across the studies was observed. Study limitations included potential bias during data extraction because this was performed by a single reviewer, and language restrictions to include only English titles. Iomeprol may be better for use in the clinical setting because of more a predictable renal safety profile. / Health Studies / M. P. H. (Health Studies)
23

Geração de microbolhas monodispersas utilizando o óleo de girassol como revestimento lipídico

Araújo Filho, Walter Duarte de 16 April 2013 (has links)
Programa de Apoio à Capacitação Docente (PAC) - Universidade do Estado da Bahia (UNEB) / As microbolhas foram inicialmente introduzidas como agentes de contraste para ultrassonografia. Elas são capazes de modificar a relação de sinal-ruído em imagens, melhorando assim a avaliação da informação clínica sobre o tecido humano. Desenvolvimentos recentes têm demonstrado a viabilidade do uso destas bolhas como portadores na entrega localizada de fármacos. Nos dispositivos microfluídicos utilizados para a geração das microbolhas, elas são formadas na interface gás-líquido por meio de um processo de estrangulamento. O dispositivo que utiliza estas funcionalidades pode produzir microbolhas com uma pequena dispersão de tamanho em uma única etapa. O dispositivo T-junction proposto para a geração de microbolhas, foi fabricado utilizando a técnica de impressão 3D. O óleo de girassol foi utilizado como camada lipídica de revestimento das microbolhas. Foram levantadas curvas de distribuição do diâmetro das microbolhas em relação ao número de eventos (microbolhas geradas em um intervalo de tempo), bem como realizados estudos da estabilidade das microbolhas de diferentes diâmetros geradas a partir de uma mesma fase líquida com viscosidade conhecida, para avaliar a viabilidade da utilização destas como veículos carreadores de fármacos. As curvas de distribuição normal encontradas com pequena dispersão em relação ao diâmetro validam o processo de geração das microbolhas com baixo coeficiente de variação percentual, isto é, 0,4-1,90%. Os resultados indicaram que o dispositivo microfluídico concebido pode ser utilizado para a produção de microbolhas monodispersas usando óleo de girassol como uma matriz lipídica de revestimento. Em relação à estabilidade, a população de microbolhas tendo o ar como fase gasosa permaneceu estável durante 217 minutos para microbolhas com um diâmetro médio de 313,0 μm. Esta estabilidade foi reduzida para 121 minutos para microbolhas com diâmetro médio menor (73,7 μm). As microbolhas mostraram-se estáveis por períodos de tempo suficientemente longos para aplicações clínicas, mesmo utilizando o ar como fase gasosa. A estabilidade das microbolhas pode ser melhorada com a utilização de gases biocompatíveis de massas molares mais elevadas e menor permeabilidade relativa em relação à água (PFB ou PFC). Foram também realizados estudos para caracterizar os padrões de fluxo, enfatizando a região onde as microbolhas eram geradas, além do levantamento do mapa de regime de fluxo para a região supracitada. Os resultados mostraram objetivamente as características dinâmicas do processo de geração, fornecendo indicações precisas dos parâmetros físicos relacionados com a produção de microbolhas monodispersas voltadas para aplicações clínicas. / Microbubbles were initially introduced as contrast agents for ultrasound examinations as they are able to modify the signal-to-noise ratio in imaging, thus improving the assessment of clinical information on human tissue. Recent developments have demonstrated the feasibility of using these bubbles as drug carriers in localized delivery. In micro fluidics devices used for microbubbles generation, the bubbles are formed at the liquid gas interface through a strangulation process. A device that uses these features can produce microbubbles with small size dispersion in a single step. A T-junction micro fluidic device constructed using 3D prototyping was made for the production of mono dispersed microbubbles. These microbubbles use sunflower oil as a lipid layer. Were raised distribution curves of the diameter of the microbubbles in the number of events (microbubbles generated in a time interval). Stability studies for microbubbles with different diameters generated from a liquid phase of the same viscosity was conducted to evaluate whether microbubbles have the potential to be used as drug carriers. The biocompatibility of the coating layer, the ability to withstand pressure variations are essential for the microbubbles to be safely used in the role of drug transporters. The normal distribution curves found with small dispersion in relation to the diameter validates the process of generation of microbubbles with a low percentage coefficient of variation e, i.e., from 0.4 to 1.90%. The results indicated that the microfluidic device conceived can be used to produce microbubbles with low percentage coefficient of variation, using sunflower oil as a coating matrix. The population of microbubbles with air as the gas phase remained stable for 217 minutes for microbubbles with a mean diameter of 313.0 m. This stability decreased to 121 minutes for microbubbles with smaller mean diameter (73.7 m). These carrier units shown to be stable for periods of time long enough for clinical applications, even when using air as gaseous phase. The stability of the microbubbles can be improved with the use of biocompatible gases of higher molar mass and lower permeability relative to water (PFB or PFC). Studies were also performed to characterize the flow patterns where the region emphasizing the microbubbles was generated and a survey map flow regime in the region mentioned above. The results objectively illustrate the dynamic of the bubble generation process providing accurate indications of the physical parameters related to the production of microbubbles monodisperse oriented to clinical applications.
24

Geração de microbolhas monodispersas utilizando o óleo de girassol como revestimento lipídico

Araújo Filho, Walter Duarte de 16 April 2013 (has links)
Programa de Apoio à Capacitação Docente (PAC) - Universidade do Estado da Bahia (UNEB) / As microbolhas foram inicialmente introduzidas como agentes de contraste para ultrassonografia. Elas são capazes de modificar a relação de sinal-ruído em imagens, melhorando assim a avaliação da informação clínica sobre o tecido humano. Desenvolvimentos recentes têm demonstrado a viabilidade do uso destas bolhas como portadores na entrega localizada de fármacos. Nos dispositivos microfluídicos utilizados para a geração das microbolhas, elas são formadas na interface gás-líquido por meio de um processo de estrangulamento. O dispositivo que utiliza estas funcionalidades pode produzir microbolhas com uma pequena dispersão de tamanho em uma única etapa. O dispositivo T-junction proposto para a geração de microbolhas, foi fabricado utilizando a técnica de impressão 3D. O óleo de girassol foi utilizado como camada lipídica de revestimento das microbolhas. Foram levantadas curvas de distribuição do diâmetro das microbolhas em relação ao número de eventos (microbolhas geradas em um intervalo de tempo), bem como realizados estudos da estabilidade das microbolhas de diferentes diâmetros geradas a partir de uma mesma fase líquida com viscosidade conhecida, para avaliar a viabilidade da utilização destas como veículos carreadores de fármacos. As curvas de distribuição normal encontradas com pequena dispersão em relação ao diâmetro validam o processo de geração das microbolhas com baixo coeficiente de variação percentual, isto é, 0,4-1,90%. Os resultados indicaram que o dispositivo microfluídico concebido pode ser utilizado para a produção de microbolhas monodispersas usando óleo de girassol como uma matriz lipídica de revestimento. Em relação à estabilidade, a população de microbolhas tendo o ar como fase gasosa permaneceu estável durante 217 minutos para microbolhas com um diâmetro médio de 313,0 μm. Esta estabilidade foi reduzida para 121 minutos para microbolhas com diâmetro médio menor (73,7 μm). As microbolhas mostraram-se estáveis por períodos de tempo suficientemente longos para aplicações clínicas, mesmo utilizando o ar como fase gasosa. A estabilidade das microbolhas pode ser melhorada com a utilização de gases biocompatíveis de massas molares mais elevadas e menor permeabilidade relativa em relação à água (PFB ou PFC). Foram também realizados estudos para caracterizar os padrões de fluxo, enfatizando a região onde as microbolhas eram geradas, além do levantamento do mapa de regime de fluxo para a região supracitada. Os resultados mostraram objetivamente as características dinâmicas do processo de geração, fornecendo indicações precisas dos parâmetros físicos relacionados com a produção de microbolhas monodispersas voltadas para aplicações clínicas. / Microbubbles were initially introduced as contrast agents for ultrasound examinations as they are able to modify the signal-to-noise ratio in imaging, thus improving the assessment of clinical information on human tissue. Recent developments have demonstrated the feasibility of using these bubbles as drug carriers in localized delivery. In micro fluidics devices used for microbubbles generation, the bubbles are formed at the liquid gas interface through a strangulation process. A device that uses these features can produce microbubbles with small size dispersion in a single step. A T-junction micro fluidic device constructed using 3D prototyping was made for the production of mono dispersed microbubbles. These microbubbles use sunflower oil as a lipid layer. Were raised distribution curves of the diameter of the microbubbles in the number of events (microbubbles generated in a time interval). Stability studies for microbubbles with different diameters generated from a liquid phase of the same viscosity was conducted to evaluate whether microbubbles have the potential to be used as drug carriers. The biocompatibility of the coating layer, the ability to withstand pressure variations are essential for the microbubbles to be safely used in the role of drug transporters. The normal distribution curves found with small dispersion in relation to the diameter validates the process of generation of microbubbles with a low percentage coefficient of variation e, i.e., from 0.4 to 1.90%. The results indicated that the microfluidic device conceived can be used to produce microbubbles with low percentage coefficient of variation, using sunflower oil as a coating matrix. The population of microbubbles with air as the gas phase remained stable for 217 minutes for microbubbles with a mean diameter of 313.0 m. This stability decreased to 121 minutes for microbubbles with smaller mean diameter (73.7 m). These carrier units shown to be stable for periods of time long enough for clinical applications, even when using air as gaseous phase. The stability of the microbubbles can be improved with the use of biocompatible gases of higher molar mass and lower permeability relative to water (PFB or PFC). Studies were also performed to characterize the flow patterns where the region emphasizing the microbubbles was generated and a survey map flow regime in the region mentioned above. The results objectively illustrate the dynamic of the bubble generation process providing accurate indications of the physical parameters related to the production of microbubbles monodisperse oriented to clinical applications.
25

Qualidade da imagem, limiar de contraste e dose glandular média em mamografia digital CR

Jakubiak, Rosangela Requi 30 January 2013 (has links)
Em muitos países, os sistemas de radiologia computadorizada (CR) representam a maioria dos equipamentos usados em mamografia digital. Este estudo apresenta um método para a otimização da qualidade da imagem e da dose em mamografia digital CR para pacientes com mamas de espessuras entre 45 e 75. As espessuras das mamas foram simuladas com placas de polimetilmetacrilato (PMMA). Técnicas de exposição otimizadas (tensão (kV), produto corrente-tempo (mAs) e combinação alvo/filtro) foram definidas como aquelas que fornecem uma razão contraste-ruído (CNR) ideal, denominada CNR alvo, que permite atingir o limiar de contraste das imagens do detalhe de diâmetro de 0,10 mm no simulador CDMAM (versão 3.4 Artinis Medical Systems, Netherlands) com um padrão de Dose Glandular Média (DGM) aceitável. Os resultados foram utilizados para os ajustes do Controle Automático de Exposição (CAE) pela equipe de manutenção. Um estudo retrospectivo de dois grupos de pacientes (Grupo 1-antes do ajuste do CAE e Grupo 2- após o ajuste do CAE) foi realizado. Os parâmetros de exposição foram reproduzidos nos simuladores para a determinação da CNR, da DGM e do limiar de contraste. As imagens clínicas destes pacientes foram analisadas por três radiologistas especialistas em mamografia que responderam questões sobre as estruturas anatômicas, ruído e contraste em áreas de valores de pixels altos ou baixos, sobre nitidez e contraste da imagem. Os resultados mostram que o método proposto foi efetivo para todas as espessuras de mama avaliadas. O ajuste do CAE proporcionou a concentração de valores da CNR no Grupo 2 mais próximas ao CNR alvo e que, mesmo como aumento do nível de ruído nas imagens clínicas, as análises do CDMAM mostraram que não houve prejuízo na identificação do objeto de 0,10 mm de diâmetro. Finalmente, este estudo conclui que o uso dos CAE das unidades de raios X baseados em fornecer uma dose constante ao detector pode ocasionar algumas dificuldades para alguns sistemas CR operarem nas condições ótimas. / In many countries, computed radiography (CR) systems represent the majority of equipments used in digital mammography. This study presents a method for optimizing image quality and dose in CR mammography of patients with breast thicknesses between 45 to 75mm. The breast thicknesses were simulated with polymethylmetacrylate (PMMA). Optimazed exposure parameters ((voltage (kV), mA and time product (mAs) and target/filter combination)) was defined as giving an ideal contrast to noise ratio (CNR), defined as target CNR, to reach the threshold contrast of CDMAM (version 3.4) phantom (Artinis Medical Systems, Netherlands) images for acceptable mean glandular dose (MGD). These results were used for adjustments in the automatic exposure control (AEC) by the maintenance team. A retrospective study of two groups of patients (Group 1-before AEC adjustment and Group 2- after AEC adjustment) were done. The exposure parameters were reproduced in the phantoms to determine of CNR, MGD and threshold contrast. The clinical images of these patients were analyzed by three experienced radiologists who answered questions about anatomical structures, noise and contrast in low and high pixel value areas and image sharpness and contrast. The results showed that the proposed method was effective for all breast thickness evaluated. The AEC adjustment showed a concentration of CNR in Group 2 nearer of target CNR, and that the increasing of noise in clinical images, the CDMAM analysis showed that this level of noise did not disturb the detail of 0,1 mm diameter. Finally, this study also concluded that the use AEC of X rays unit based on constant dose to the detector may bring some difficulties to CR systems operate in optimal conditions.
26

Qualidade da imagem, limiar de contraste e dose glandular média em mamografia digital CR

Jakubiak, Rosangela Requi 30 January 2013 (has links)
Em muitos países, os sistemas de radiologia computadorizada (CR) representam a maioria dos equipamentos usados em mamografia digital. Este estudo apresenta um método para a otimização da qualidade da imagem e da dose em mamografia digital CR para pacientes com mamas de espessuras entre 45 e 75. As espessuras das mamas foram simuladas com placas de polimetilmetacrilato (PMMA). Técnicas de exposição otimizadas (tensão (kV), produto corrente-tempo (mAs) e combinação alvo/filtro) foram definidas como aquelas que fornecem uma razão contraste-ruído (CNR) ideal, denominada CNR alvo, que permite atingir o limiar de contraste das imagens do detalhe de diâmetro de 0,10 mm no simulador CDMAM (versão 3.4 Artinis Medical Systems, Netherlands) com um padrão de Dose Glandular Média (DGM) aceitável. Os resultados foram utilizados para os ajustes do Controle Automático de Exposição (CAE) pela equipe de manutenção. Um estudo retrospectivo de dois grupos de pacientes (Grupo 1-antes do ajuste do CAE e Grupo 2- após o ajuste do CAE) foi realizado. Os parâmetros de exposição foram reproduzidos nos simuladores para a determinação da CNR, da DGM e do limiar de contraste. As imagens clínicas destes pacientes foram analisadas por três radiologistas especialistas em mamografia que responderam questões sobre as estruturas anatômicas, ruído e contraste em áreas de valores de pixels altos ou baixos, sobre nitidez e contraste da imagem. Os resultados mostram que o método proposto foi efetivo para todas as espessuras de mama avaliadas. O ajuste do CAE proporcionou a concentração de valores da CNR no Grupo 2 mais próximas ao CNR alvo e que, mesmo como aumento do nível de ruído nas imagens clínicas, as análises do CDMAM mostraram que não houve prejuízo na identificação do objeto de 0,10 mm de diâmetro. Finalmente, este estudo conclui que o uso dos CAE das unidades de raios X baseados em fornecer uma dose constante ao detector pode ocasionar algumas dificuldades para alguns sistemas CR operarem nas condições ótimas. / In many countries, computed radiography (CR) systems represent the majority of equipments used in digital mammography. This study presents a method for optimizing image quality and dose in CR mammography of patients with breast thicknesses between 45 to 75mm. The breast thicknesses were simulated with polymethylmetacrylate (PMMA). Optimazed exposure parameters ((voltage (kV), mA and time product (mAs) and target/filter combination)) was defined as giving an ideal contrast to noise ratio (CNR), defined as target CNR, to reach the threshold contrast of CDMAM (version 3.4) phantom (Artinis Medical Systems, Netherlands) images for acceptable mean glandular dose (MGD). These results were used for adjustments in the automatic exposure control (AEC) by the maintenance team. A retrospective study of two groups of patients (Group 1-before AEC adjustment and Group 2- after AEC adjustment) were done. The exposure parameters were reproduced in the phantoms to determine of CNR, MGD and threshold contrast. The clinical images of these patients were analyzed by three experienced radiologists who answered questions about anatomical structures, noise and contrast in low and high pixel value areas and image sharpness and contrast. The results showed that the proposed method was effective for all breast thickness evaluated. The AEC adjustment showed a concentration of CNR in Group 2 nearer of target CNR, and that the increasing of noise in clinical images, the CDMAM analysis showed that this level of noise did not disturb the detail of 0,1 mm diameter. Finally, this study also concluded that the use AEC of X rays unit based on constant dose to the detector may bring some difficulties to CR systems operate in optimal conditions.
27

Knowledge, clinical competencies and medico legal responsibilities required for the administration of intravenous contrast media by radiographers

Koch, Gerhardus George Visser January 2017 (has links)
Submitted in fulfillment of the requirements for the Degree of Master of Health Sciences in Radiography, Durban University of Technology, 2017. / Background The current scope of practice for diagnostic radiographers, does not allow them to administer intravenous contrast media (IVCM) since there are no formal training guidelines accredited by the Health Professions Council of South Africa (HPCSA) (Koch 2014: 26). In selected countries abroad, radiographers are allowed to administer IVCM and have thus received the necessary and accredited training to do so. In view of this, the South African radiographer’s scope of practice is not on par with the selected countries. The radiologists in South Africa (SA) who are currently responsible for the administration of IVCM have issued a position statement which supports, in principle, the idea of radiographers administering IVCM should they receive the necessary and appropriate training to do so (RSSA 2011: 1-2). The aim of this research study was, therefore, to investigate the radiologists’ perspectives regarding the theoretical knowledge, clinical competencies and medico legal responsibilities required by radiographers in order to effectively administer IVCM. This research study provides input for the development of national training guidelines for radiographers to administer IVCM. Research Methodology A quantitative, descriptive study was conducted by targeting qualified radiologists residing and practicing within the province of KwaZulu Natal (KZN). Ethical approval was obtained from the Durban University of Technology’s (DUT) Institutional Research and Ethics Committee (IREC). All the participants were contacted in their personal capacity. The research tool was an online survey administered through SurveyMonkey which included questions and statements relating to the administration of IVCM and was structured so as to meet the study objectives. The research tool was evaluated and amended by an expert focus group to ensure reliability and validity. Confidentiality was maintained and all the data obtained during this research study was password protected. Results and discussion Fifty-nine radiologists (60.8 percent) participated in this study. Twelve respondents, however, were excluded due to incomplete surveys. The final response rate, therefore, was 48.5 percent (n=47) of which 72.3 percent of the respondents were from the private sector. Results illustrated the radiologists’ agreement regarding the theoretical, clinical/practical and medico legal training components for inclusion in the further training of radiographers to administer IVCM. Most respondents supported the inclusion of three assessments: theoretical (87.2 percent), clinical (93.6 percent) and a record of clinical competencies (95.7 percent). The assessments were considered equally important in terms of percentage weighting. The overall results compared favorably to the current international trends and practice standards of radiographers administering IVCM. Conclusion and Recommendations The study, in providing key data for the development of training guidelines for radiographers to administer IVCM, has demonstrated the importance of higher education (HE) and training in addressing transformation in health services with particular reference to professional scopes of practice. Furthermore, it reinforces the need for local research that will inform HE and training and hence a scope of practice that meets local needs. It was recommended that future studies should include those HE institutions offering training in Radiography as well as their stakeholders for the design and transformation of a national curriculum for radiographers to administer IVCM. / M
28

Desenvolvimento de metodologia para análise de arborescências em materiais dielétricos por contraste de fase de raios X

Ribeiro Júnior, Sebastião 17 September 2013 (has links)
A ocorrência de arborescências em água (water tree) ou elétrica (electrical tree) é apontada como o principal fenômeno de degradação em isolações sólidas de cabos de distribuição de energia elétrica. A evolução destas arborescências pode levar a camada de isolação à ruptura dielétrica e, como conseqüência, à falha destes equipamentos, com a interrupção do fornecimento de energia elétrica. O entendimento deste fenômeno é necessário para desenvolver métodos de análise e prevenção da ruptura de materiais isolantes. Este trabalho mostra a aplicação da técnica contraste de fase por raios X como metodologia para o estudo das arborescências formadas em materiais isolantes de borracha de propileno etileno (EPR) e polietileno reticulado (XLPE). / The water tree or electrical tree occurrence is identified as the main phenomena in the degradation in solid isolations of the electric energy distribution cables. The water tree evolution can lead to dielectric breakdown of the isolation layer and, consequently, to the failure this equipment and the interruption of the electric energy supply. The understanding this phenomenon is necessary for the development analysis methods and to prevent collapse in the polymeric insulation. This work demonstrates the application of X-ray phase contrast technique as a methodology for the study of the water tree and electrical tree in Ethylene propylene rubber (EPR) and crosslinked polyethylene (XLPE).
29

Controle de qualidade, medição de dose glandular média e protocolo de rotina para tomossíntese digital mamária / Quality control, mean glandular dose and routine protocol in digital tomosynthesis breast

Messias, Pricila Cordeiro 22 August 2016 (has links)
No Brasil, o câncer de mama é o mais frequente e a principal causa de morte entre as mulheres, para o ano de 2016 foram estimados 57.960 mil novos casos. A Tomossíntese Digital Mamária (TDM) reduz os efeitos da sobreposição do tecido da mama, oferecendo uma melhor caracterização dos achados mamográficos e diminuindo a necessidade de incidências adicionais. A recente introdução da TDM na prática clínica requer manutenção dos requisitos de dose e qualidade da imagem, além de rotinas de Controle de Qualidade (CQ) e monitoração da Dose Glandular Média (DGM), e também uma equipe técnica qualificada para executar o procedimento. A prática de monitoração da qualidade da imagem e da dose de radiação é uma solução para assegurar continuamente a alta qualidade de exames de radiodiagnóstico. São poucos os estudos relacionados ao CQ em TDM no Brasil, e ainda não foram estabelecidos protocolos nacionais e internacionais específicos; sendo assim, os testes de CQ utilizados são baseados naqueles utilizados pela National Health Service Breast Screening Programme (NHSBSP), European Reference Organisation for Quality Assured Breast Screening and Diagnostic Service (EUREF), American Association of Physicists in Medicine (AAPM), Internacional Atomic Energy Agency (IAEA). Este estudo propõe e apresenta os resultados dos testes de CQ e DGM para mamografia e TDM, e um Protocolo de Rotina para exames de TDM. Os testes de CQ para TDM foram realizados conforme as recomendações do fabricante, da Portaria 2898/13 e de protocolos internacionais. O Protocolo de Rotina foi elaborado visando sanar as dúvidas mais frequentes da equipe técnica, assim como otimizar a qualidade do exame em sala. Para atestar a qualidade da imagem diagnóstica para todas as espessuras, foi realizado o teste de Qualidade de Imagem do simulador padrão do American College of Radiology (ACR). Na avaliação da DGM todos os valores obtidos para mamografia e TDM se mantiveram em conformidade com os limites de referência utilizados, exceto para a espessura de 20 mm em TDM. Para todos os outros testes de CQ, os resultados se mantiveram em conformidade com os limites de referência. Os resultados adquiridos nas avaliações reforçam a importância do controle de qualidade aplicado de forma adequada no processo de obtenção das imagens, assegurando baixa dose e boa qualidade da imagem, cumprindo o princípio ALARA. / In Brazil, breast cancer is the most common and the leading cause of death among women; in 2015, 57,120,000 new cases. Digital Breast Tomosynthesis (DBT) reduces the effects of overlapping breast tissue, offering a better characterization of mammographic findings and decreasing the need of additional views. The recent introduction of DBT in clinical practice requires, in order to maintain the dose requirements and image quality, aside from routine Quality Control (QC) procedures and monitoring the Mean Glandular Dose (MGD) also a qualified technical team to perform the procedure. The practice of monitoring the image quality and the radiation dose is a solution to continuously ensure high quality diagnostic radiology exams. Few studies related to CQ TDM in Brazil, and national and international specific protocols have not been established, Thus, QC tests used are based on those used by the National Health Service Breast Screening Programme (NHSBSP), European Reference Organization for Quality Assured Breast Screening and Diagnostic Service (EUREF), American Association of Physicists in Medicine (AAPM), International Atomic Energy Agency (IAEA). This study proposes and presents the results of the QC tests and DGM for mammography and TDM, and routine protocol for TDM tests. The QC tests for TDM were performed according to the manufacturer's recommendations, of Portaria 2898/13 and international protocols. The Routine Protocol was elaborated aiming to resolve the most frequent doubts of the technical team, as well as optimize the room examination. In order to certify the quality of the diagnostic image for all thicknesses, a imagine quality test from the standard simulator of American College of Radiology (ACR) was performed. In the DGM evaluation, all values mammography and TDM remained in accordance with the reference range used except for 20 mm TDM. For all other QC tests, the results remained in accordance with the reference limits. The results obtained in the assessments emphasize the importance of quality control applied properly in obtaining the imaging process, ensuring low dose and good image quality, fulfilling the ALARA principle.
30

Controle de qualidade, medição de dose glandular média e protocolo de rotina para tomossíntese digital mamária / Quality control, mean glandular dose and routine protocol in digital tomosynthesis breast

Messias, Pricila Cordeiro 22 August 2016 (has links)
No Brasil, o câncer de mama é o mais frequente e a principal causa de morte entre as mulheres, para o ano de 2016 foram estimados 57.960 mil novos casos. A Tomossíntese Digital Mamária (TDM) reduz os efeitos da sobreposição do tecido da mama, oferecendo uma melhor caracterização dos achados mamográficos e diminuindo a necessidade de incidências adicionais. A recente introdução da TDM na prática clínica requer manutenção dos requisitos de dose e qualidade da imagem, além de rotinas de Controle de Qualidade (CQ) e monitoração da Dose Glandular Média (DGM), e também uma equipe técnica qualificada para executar o procedimento. A prática de monitoração da qualidade da imagem e da dose de radiação é uma solução para assegurar continuamente a alta qualidade de exames de radiodiagnóstico. São poucos os estudos relacionados ao CQ em TDM no Brasil, e ainda não foram estabelecidos protocolos nacionais e internacionais específicos; sendo assim, os testes de CQ utilizados são baseados naqueles utilizados pela National Health Service Breast Screening Programme (NHSBSP), European Reference Organisation for Quality Assured Breast Screening and Diagnostic Service (EUREF), American Association of Physicists in Medicine (AAPM), Internacional Atomic Energy Agency (IAEA). Este estudo propõe e apresenta os resultados dos testes de CQ e DGM para mamografia e TDM, e um Protocolo de Rotina para exames de TDM. Os testes de CQ para TDM foram realizados conforme as recomendações do fabricante, da Portaria 2898/13 e de protocolos internacionais. O Protocolo de Rotina foi elaborado visando sanar as dúvidas mais frequentes da equipe técnica, assim como otimizar a qualidade do exame em sala. Para atestar a qualidade da imagem diagnóstica para todas as espessuras, foi realizado o teste de Qualidade de Imagem do simulador padrão do American College of Radiology (ACR). Na avaliação da DGM todos os valores obtidos para mamografia e TDM se mantiveram em conformidade com os limites de referência utilizados, exceto para a espessura de 20 mm em TDM. Para todos os outros testes de CQ, os resultados se mantiveram em conformidade com os limites de referência. Os resultados adquiridos nas avaliações reforçam a importância do controle de qualidade aplicado de forma adequada no processo de obtenção das imagens, assegurando baixa dose e boa qualidade da imagem, cumprindo o princípio ALARA. / In Brazil, breast cancer is the most common and the leading cause of death among women; in 2015, 57,120,000 new cases. Digital Breast Tomosynthesis (DBT) reduces the effects of overlapping breast tissue, offering a better characterization of mammographic findings and decreasing the need of additional views. The recent introduction of DBT in clinical practice requires, in order to maintain the dose requirements and image quality, aside from routine Quality Control (QC) procedures and monitoring the Mean Glandular Dose (MGD) also a qualified technical team to perform the procedure. The practice of monitoring the image quality and the radiation dose is a solution to continuously ensure high quality diagnostic radiology exams. Few studies related to CQ TDM in Brazil, and national and international specific protocols have not been established, Thus, QC tests used are based on those used by the National Health Service Breast Screening Programme (NHSBSP), European Reference Organization for Quality Assured Breast Screening and Diagnostic Service (EUREF), American Association of Physicists in Medicine (AAPM), International Atomic Energy Agency (IAEA). This study proposes and presents the results of the QC tests and DGM for mammography and TDM, and routine protocol for TDM tests. The QC tests for TDM were performed according to the manufacturer's recommendations, of Portaria 2898/13 and international protocols. The Routine Protocol was elaborated aiming to resolve the most frequent doubts of the technical team, as well as optimize the room examination. In order to certify the quality of the diagnostic image for all thicknesses, a imagine quality test from the standard simulator of American College of Radiology (ACR) was performed. In the DGM evaluation, all values mammography and TDM remained in accordance with the reference range used except for 20 mm TDM. For all other QC tests, the results remained in accordance with the reference limits. The results obtained in the assessments emphasize the importance of quality control applied properly in obtaining the imaging process, ensuring low dose and good image quality, fulfilling the ALARA principle.