• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 21
  • 14
  • 7
  • 1
  • Tagged with
  • 50
  • 50
  • 17
  • 17
  • 8
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Enhancing quality of life through aquatics therapy : effectiveness of adaptation of seating posture loading in a partially immersed aquatics therapy approach for the improved functioning and perceived competence of children with cerebral palsy, as reflected in their quality of life : a multiple case study

Shelef, Arie Niv January 2010 (has links)
An innovative Partially Immersed Approach, based on mixed principles of land and aquatic therapy theories was developed to enhance sitting adaptation and functioning in an Aquatics Therapy environment, thus improving quality of life for children with Cerebral Palsy. The approach aimed to enhance motor adaptation, engendering adaptation in psychosocial domains of quality of life. It employed a specially developed therapeutic treatment chair, in an unloading toward loading strategy, to regulate and control percentage of weight-bearing by manipulation of buoyancy (Archimedes principle). Participants were bilateral spastic hypertonia, Cerebral Palsy children, aged 10-15 years. Mixed-method methodology was used to investigate effectiveness of treatment, employing a small sample in a multiple case study. In conclusion, the developed approach enables aquatic therapy to be employed to improve motor function adaptation on land and consequently enhancing adaptation in other psychosocial domains - perceived competence, empowerment and motivation - thus improving quality of life for children with cerebral palsy, sustained at a one-year post-intervention test.
12

Quality engineering applications on single and multiple nonlinear profiles

Chou, Shih-Hsiung January 1900 (has links)
Doctor of Philosophy / Department of Industrial and Manufacturing Systems Engineering / Shing I. Chang / Profile analysis has drawn attention in quality engineering applications due to the growing use of sensors and information technologies. Unlike the conventional quality characteristics of interest, a profile is formed functionally dependent on one or more explanatory variables. A single profile may contain hundred or thousand data points. The conventional charting tools cannot handle such high dimensional datasets. In this dissertation, six unsolved issues are investigated. First, Chang and Yadama’s method (2010) shows competitive results in nonlinear profile monitoring. However, the effectiveness of removing noise from given nonlinear profile by using B-splines fitting with and without wavelet transformation is unclear. Second, many researches dealt with profile analysis problem considering whether profile shape change only or variance change only. Those methods cannot identify whether the process is out-of-control due to mean or variance shift. Third, methods dealing with detecting profile shape change always assume that a gold standard profile exists. The existing profile shape change detecting methods are hard to be implemented directly. Fourth, multiple nonlinear profiles situation may exist in real world applications, so that conventional single profile analysis methods may result in high false alarm rate when dealing multiple profile scenario. Fifth, Multiple nonlinear profiles situation may be also happened in designs of experiment. In a conventional experimental design, the response variable is usually considered a single value or a vector. The conventional approach cannot deal with when the format of the response factor as multiple nonlinear profiles. Finally, profile fault diagnosis is an important step after detecting out-of-control signal. However, current approaches will lead to large number of combinations if the number of sections is too large. The organization of this dissertation is as following. Chapter 1 introduce the profile analysis, current solutions, and challenges; Chapter 2 to Chapter 4 explore the unsolved challenges in single profile analysis; Chapter 5 and Chapter 6 investigate multiple profiles issues in profile monitoring analysis and experimental design method. Chapter 7 proposed a novel high-dimensional diagnosis control chart to diagnose the cause of out-of-control signal via visualization aid. Finally, Chapter 8 summarizes the achievements and contributions of this research.
13

Desenvolvimento de um sistema de referência para determinação do equivalente de dose pessoal e da constância de feixes de radiação X / Development of a reference system for the determination of the personal dose equivalent and the constancy of X-ray beams

Vivolo, Vitor 09 February 2006 (has links)
Um sistema de referência para determinação do equivalente de dose pessoal, HP (10), e um programa de controle da qualidade de sistemas geradores de raios X utilizados em radioproteção inclui a verificação periódica da constância dos feixes de raios X empregados na calibração de instrumentos medidores de radiação em laboratórios de calibração de instrumentos. Neste trabalho foram desenvolvidas duas câmaras de ionização de placas paralelas inseridas em objetos simuladores de tronco humano. Uma das câmaras de ionização possui eletrodo coletor de grafite, para a medida do equivalente de dose pessoal; a segunda câmara de ionização foi confeccionada com eletrodo coletor de alumínio para, juntamente com a primeira câmara de ionização, formarem um sistema Tandem. A dependência energética diferente da resposta das duas câmaras de ionização é que permite a formação do sistema Tandem, que apresenta grande utilidade na verificação da constância de feixes de radiação X. Foram ainda implantados feixes padronizados de radiação X de energias médias (48 keV a 118 keV), nível radioproteção, por meio do desenvolvimento de uma metodologia dosimétrica e da análise dos parâmetros físicos destes feixes. As câmaras desenvolvidas foram testadas em relação às suas características operacionais e foram calibradas em feixes de radiação X, níveis radioproteção, radiodiagnóstico, mamografia e radioterapia, e ainda em campos de radiação gama, seguindo as recomendações internacionais. Apresentaram bom desempenho. Foi estabelecido o procedimento da determinação do equivalente de dose pessoal, Hp (10). / A reference system for the determination of the personal dose equivalent, HP (10), and a quality control program of X-ray equipments used in radioprotection require the periodic verification of the X-ray beams constancy. In this work, two parallel-plate ionization chambers were developed with inner electrodes of different materials, and inserted into PMMA slab phantoms. One ionization chamber was developed with inner carbon electrodes and the other with inner aluminium electrodes. The two ionization chambers can be used as a Tandem system. The different energy response of the two ionization chambers allowed the development of the Tandem system that is very useful for the checking of the constancy of beam qualities. Standard intermediary energy X-ray beams (from 48 keV to 118 keV), radioprotection level, were established through the development of a dosimetric methodology and the analysis of their physical parameters. The ionization chambers were studied in relation to their operational characteristics, and they were calibrated in X-ray beams (radioprotection, diagnostic radiology, mammography and radiotherapy levels) in accordance to international recommendations. They presented good performance. The determination procedure of personal dose equivalent, HP (10), was established.
14

Estudos espectrais aplicados à radioterapia utilizando o método de Monte Carlo / Spectral studies applied to radiation therapy using the Monte Carlo method.

Costa, Gustavo de Menezes Pontes da 21 October 2013 (has links)
O controle da qualidade é uma prática essencial em radioterapia para se garantir que a dose prescrita seja realmente entregue ao paciente. Essa etapa da radioterapia é fundamental para o sucesso do tratamento, pois sem executá -lo o paciente pode ser subdosado ou sobredosado sem que o físico médico possa estimar o erro estabelecido entre a dose prescrita e dose recebida. Dentre os métodos para o controle da qualidade em radioterapia, as dosimetrias in vivo permitem determinar as doses recebidas pelo paciente durante o tratamento. Diferentes técnicas podem ser utilizadas em dosimetria in vivo, sendo uma das mais comuns a dosimetria por transmissão, que compreende a comparação entre os sinais de um dado dosímetro posicionado na entrada e na saída do paciente , nas condições de irradiação. Desta forma, o conhecimento dos espectros incidente e transmitido pelo paciente podem ser utilizados tanto para o cálculo das doses em profundidade no paciente quanto para a correção de resposta de dosímetros em dosimetrias in vivo por transmissão. O método Monte Carlo pode ser utilizado para reproduzir diversas situações desejadas em radioterapia, que pode ser tanto, em controle da qualidade como, em tratamentos, por ser uma ferramenta acurada e sem restrições físicas e financeiras. Esse trabalho se propõe a determinar a perturbação sofrida pelo feixe primário ao atravessar objetos simuladores por meio da determinação da fluência energética e da energia depositada em diferentes condições de irradiação, através do método Monte Carlo. Neste trabalho foi desenvolvida uma quantidade de situações utilizando-se o código PENELOPE para possibilitar a análise do comportamento de fluências energéticas e energias depositadas. Os parâmetros clínicos que sofreram variação para a analise foram a espessura do objeto simulador, o tamanho de campo e a distância fonte-superfície (DFS). Os resultados deste trabalho mostram que a dependência em relação a cada parâmetro clínico é diferente, como é o caso da DFS, que influência mais na resposta do que o tamanho de campo, por exemplo. Portanto, esse trabalho pode ser uma ferramenta para trabalhos posteriores no estabelecimento de protocolos de relação entre fluência e dose, bem como, de armazenamento ou aplicação de dose em pacientes. / Quality control is an essential practice in radiation oncology in order to ensure that the prescribed dose is delivered to the patient. This step of radiation therapy is very important to successful treatment, because without it the patient may receive bellow dose or over dose without the physical doctor can estimate the error established between the prescribed dose and dose received. One of the methods for quality control in radiotherapy, the in vivo dosimetry let you determine the doses received by the patient during the treatment. Different techniques can be used in vivo dosimetry, being one of the most common dosimetry for transmission, which includes the comparison of the signs of a dosimeter placed on the entrance and exit of patient irradiation conditions. In this way, the knowledge of incident spectra and transmitted by the patient can be used for both the calculation of doses in depth in the patient as to the dosimeter response in vivo dosimetry for transmission. The Monte Carlo method can be used to make a variety of situations you want in radiotherapy, and may be as much in quality as in control treatments for being a tool accurately and without physical and financial constraints. This work aims to determine the disturbance suffered by primary beam across objects simulators through determination of energy flow and energy deposited in different irradiation conditions through the Monte Carlo method. This work was developed a number of situations using the PENELOPE code to enable the analysis of the behavior of energy deposited energies and skills. The clinical parameters that have suffered the assess variation ranges were the thickness of the object Simulator, the field size and source surface distance (SSD). The results show that the dependence on each clinical parameter is different, as is the case of DFS, which most influence on response than the field size, for example. Therefore, this work can be a tool for further work on the establishment of relationship between fluency and protocols, as well as dose, dose storage in patients.
15

Desenvolvimento de um sistema de referência para determinação do equivalente de dose pessoal e da constância de feixes de radiação X / Development of a reference system for the determination of the personal dose equivalent and the constancy of X-ray beams

Vitor Vivolo 09 February 2006 (has links)
Um sistema de referência para determinação do equivalente de dose pessoal, HP (10), e um programa de controle da qualidade de sistemas geradores de raios X utilizados em radioproteção inclui a verificação periódica da constância dos feixes de raios X empregados na calibração de instrumentos medidores de radiação em laboratórios de calibração de instrumentos. Neste trabalho foram desenvolvidas duas câmaras de ionização de placas paralelas inseridas em objetos simuladores de tronco humano. Uma das câmaras de ionização possui eletrodo coletor de grafite, para a medida do equivalente de dose pessoal; a segunda câmara de ionização foi confeccionada com eletrodo coletor de alumínio para, juntamente com a primeira câmara de ionização, formarem um sistema Tandem. A dependência energética diferente da resposta das duas câmaras de ionização é que permite a formação do sistema Tandem, que apresenta grande utilidade na verificação da constância de feixes de radiação X. Foram ainda implantados feixes padronizados de radiação X de energias médias (48 keV a 118 keV), nível radioproteção, por meio do desenvolvimento de uma metodologia dosimétrica e da análise dos parâmetros físicos destes feixes. As câmaras desenvolvidas foram testadas em relação às suas características operacionais e foram calibradas em feixes de radiação X, níveis radioproteção, radiodiagnóstico, mamografia e radioterapia, e ainda em campos de radiação gama, seguindo as recomendações internacionais. Apresentaram bom desempenho. Foi estabelecido o procedimento da determinação do equivalente de dose pessoal, Hp (10). / A reference system for the determination of the personal dose equivalent, HP (10), and a quality control program of X-ray equipments used in radioprotection require the periodic verification of the X-ray beams constancy. In this work, two parallel-plate ionization chambers were developed with inner electrodes of different materials, and inserted into PMMA slab phantoms. One ionization chamber was developed with inner carbon electrodes and the other with inner aluminium electrodes. The two ionization chambers can be used as a Tandem system. The different energy response of the two ionization chambers allowed the development of the Tandem system that is very useful for the checking of the constancy of beam qualities. Standard intermediary energy X-ray beams (from 48 keV to 118 keV), radioprotection level, were established through the development of a dosimetric methodology and the analysis of their physical parameters. The ionization chambers were studied in relation to their operational characteristics, and they were calibrated in X-ray beams (radioprotection, diagnostic radiology, mammography and radiotherapy levels) in accordance to international recommendations. They presented good performance. The determination procedure of personal dose equivalent, HP (10), was established.
16

Caracterização de dosímetros semicondutores e suas aplicações em técnicas especializadas em radioterapia / Characterization of Semiconductors Dosimeters and their Applications in Specialized Techniques in Radiation Therapy.

Oliveira, Fernanda Ferretti de 21 December 2012 (has links)
Introdução: A Radioterapia é frequentemente utilizada no tratamento do câncer, seja como uma modalidade simples ou em combinação com outras modalidades, tais como a cirurgia e a quimioterapia. Com o objetivo de eliminar células não desejadas no organismo humano, utiliza-se de radiações ionizantes para provocar a destruição de células tumorais pela absorção da energia da radiação incidente. A principal dificuldade encontrada em radioterapia é que as células tumorais não são tratadas isoladamente, isto é, o dano da radiação não é restrito somente às células tumorais, mas afeta também as células normais. Assim sendo, é essencial que a dose de radiação liberada nos tecidos normais seja tão baixa quanto possível para minimizar o risco de efeitos colaterais provocados pelos tratamentos radioterápicos. Objetivos: O objetivo deste trabalho é a caracterização de dosímetros semicondutores e dosímetros termoluminescentes e suas aplicações em técnicas não convencionais de Radioterapia. A partir da caracterização será possível a implementação dos dosímetros como sistema de dosimetria in vivo em teleterapia com feixe de fótons, visando atender as necessidades prementes do Serviço de Radioterapia do HCFMRP em implantar a técnica de irradiação de corpo inteiro e em realizar o controle de dose administrada ao paciente. Metodologia e Resultados: Diodos semicondutores foram caracterizados de acordo com o fator campo, angulação, taxa de dose, temperatura e fator bandeja, para obtenção dos fatores de correção. Verificou-se que a variação da resposta dos diodos com a temperatura, angulação e taxa de dose não foi significativa. Fatores campo foram calculados e registrados para campos de 3x3 cm 2 a 40x40cm 2 , onde se observou aumento na leitura do diodo com o aumento no campo. A resposta com a taxa de dose apr esentou pouca variação (de 100cGy/min para 300cGy/min a variação foi menor que 1,2%). O fator bandeja encontrado foi de 0,95±0,01 demonstrando que a presença da bandeja provoca diminuição na resposta do detector. Após a caracterização, os diodos foram calibrados em setup TBI para determinação dos fatores de calibração para cada espessura simulada do paciente (DLL). A dosimetria in vivo foi realizada em 3 pacientes submetidos ao tratamento de TBI do HCFMRP. A diferença percentual máxima entre as medidas com diodo e o valor nominal de dose foi de 3,6%, o que está de acordo com o recomendado pelo ICRU (+/- 5%). Os resultados demonstram a viabilidade e confiabilidade da técnica de dosimetria com diodos semicondutores para Controle de Qualidade de dose em tratamento de TBI. Ainda, dosímetros termoluminescentes foram caracterizados quanto à homogeneidade do grupo e a linearidade. Os fatores de calibração individuais foram encontrados e os dosímetros foram aplicados em simulações em setup TBI. Os cálculos de dose das simulações realizadas com os termoluminescentes inseridos nos orifícios de um OSA demonstraram concordância com os valores nominais de dose. Para as regiões do tórax superior e inferior, onde os TLD receberam doses mais elevadas (>150cGy), recomendou-se a utilização de compensadores de dose, para a prática clínica.Uma câmara de ionização foi utilizada como dosímetro de referência em todas as etapas de calibração e caracterização dos diodos e termoluminescentes. Conclusões: Este estudo mostrou que, para tratamentos de irradiação de corpo inteiro, quando o paciente estiver sendo preparado para um transplante de medula óssea, e o planejamento necessitar de uma grande eficácia na distribuição de dose, a metodologia com aplicações de dosímetros semicondutores apresenta-se como uma alternativa viável, precisa e de grande importância para o controle dosimétrico. Assim, ficou evidenciada a importância da utilização do diodo para o Controle de Qualidade, na avaliação da dos e a ser ministrada ao paciente, pelo menos em toda primeira fração de tratamento de TBI. Além disso, ficou demonstrada a aplicabilidade dos dosímetros termoluminescentes para controle dosimétrico, demonstrando o valor da dosimetria termoluminescente como um sistema de verificação de dose e sua eficácia como parte de um programa de garantia de qualidade em Radioterapia. A caracterização dos termoluminescentes evidenciou a possibilidade de aplicação da técnica TL em dosimetria in vivo. / Introduction: Radiation therapy is often used in cancer treatment, either as a single modality or in combination with other modalities, such as surgery and chemotherapy. Aiming to eliminate unwanted cells in the human body, radiation therapy uses ionizing radiation to cause destruction of tumor cells by absorbing the energy of the incident radiation. The main difficulty in radiation therapy is that tumor cells are not separately treated. The radiation damage is not restricted solely to tumor cells, but also affects normal cells. Therefore, it is essential that the radiation dose released in normal tissues is as low as possible to minimize the risk of side effects caused by radiotherapy treatments. Objectives: The objective of this work is the characterization of semiconductor dosimeters and thermoluminescent dosimeters and their applications in non -conventional radiotherapy techniques. After characterization it will be possible to implement the dosimeters as a system of in vivo dosimetry in radiotherapy with photon beam, to meet the pressing needs of the Radiotherapy Service of HCFMRP in deploying the technique of total body irradiation and make the control of dose administered to the patient . Methodology and Results: Semiconductor diodes were characterized according to the field factor, angle, dose rate, temperature and tray factor to obtain the correction factors. It was found that the variation of the response of the diodes with temperature, angle and dose rate was not significant. Field factors were calculated and recorded for fields from 3x3 cm 2 to 40x40cm 2 , wher e there was an increase in the reading of the diode with increasing field. The response with dose rate showed small variation (from 100cGy/min to 300cGy/min the variation was less than 1.2%). The tray factor was 0.95 ± 0.01 demonstrating that the tray decreases detector response. After characterization, the diodes were calibrated in TBI setup for determining the calibration factors for each simulated patient thickness (latero-lateral distance). The in vivo dosimetry was performed in 3 patients undergoing TBI treatment in HCFMRP. The maximum percentage difference between the measurements and the diode nominal dose was 3.6%, which is consistent with that recommended by ICRU (+ / - 5%). The results demonstrate the feasibility and reliability of the dosimetry technique with semiconductor diodes for dose quality control in TBI treatments. Still, dosimeters were characterized by group homogeneity and linearity. The calibration factors were found and individual dosimeters were applied in simulations with TBI setup. The dose calculation of simulations performed with the thermoluminescent inserted in holes of the phantom showed agreement with the nominal dose. For regions of the upper and lower thorax where TLD received higher doses (> 150cGy) it was recommended the use of compensating dose in clinic. An ionization chamber dosimeter was used as reference in all stages of calibration and characterization of diodes and thermoluminescents. Conclusions: This study showed that, for total body irradiation treatments, when the patient is being prepared for a bone marrow transplant, and planning requires a great effect on the dose distribution, the methodology with semiconductor dosimeters presented a viable alternative, and has great importance for the dosimetric control. The study proved the importance of diode semiconductors for quality control, for evaluation of the dose to be administered to the patient, at least throughout the first fraction of TBI treating. Furthermore, it was demonstrated the applicability of TLD for control quality, demonstrating the value of thermoluminescent dosimetry as a dose verification system and its effectiveness as part of a program of quality assurance in radiotherapy. The characterization of thermoluminescent showed the possibility of applying the TL technique in in vivo dosimetry.
17

Improving the performance of Six Sigma : a case study of the Six Sigma process at Ford Motor Company

Thompson, Steven James January 2007 (has links)
This thesis concerns the question, "Why is the performance of Six Sigma within The Ford Motor Company below that experienced in other companies, and what can be done to improve it?" The aim of the thesis was to make recommendations that would improve the performance of Six Sigma within the Ford Motor Company. Results from the literature were categorised according to headings found in the European Foundation for Quality Model (EFQM): strategy, people, process and leadership. The key factors identified from the literature review as being significant for a successful Six Sigma deployment were that projects were aligned to the strategy of the organisation, individuals were clear on their role and had appropriate skills, processes were well defined and understood and leadership team was committed to Six Sigma. The research started with a review of the results from two employee surveys. The first was given to Black Belts and asked questions concerning Six Sigma. The second was given to all the employees in the organisation. The survey data failed to identify the cause of lower than expected results, and so the investigation followed with a series of twelve interviews. When these also failed to identify the factor or factors responsible for deployment performance, the project database was reviewed. The Define, Measure, Analyse, Improve and Control steps (DMAIC) were then analysed using Gardner’s Model of Process Maturity. The thesis concluded that the main influence driving Six Sigma performance was the low process maturity of the project selection and scoping processes and this gave rise to variable project performance. The thesis then presents material to improve project performance including a process map, a process Failure Mode and Effects Analysis (FMEA) of the project selection and scoping process, a control plan that ensures that the projects are on track and a macro using Excel and Minitab that works within the Ford Motor Company system to provide automatic evaluation of projects.
18

Predicting and reducing warranty costs by considering customer expectation and product performance

Sharma, Naresh Kumar, January 2008 (has links) (PDF)
Thesis (Ph. D.)--Missouri University of Science and Technology, 2008. / Vita. The entire thesis text is included in file. Title from title screen of thesis/dissertation PDF file (viewed March 2, 2009) Includes bibliographical references (p. 216-220).
19

Estudos espectrais aplicados à radioterapia utilizando o método de Monte Carlo / Spectral studies applied to radiation therapy using the Monte Carlo method.

Gustavo de Menezes Pontes da Costa 21 October 2013 (has links)
O controle da qualidade é uma prática essencial em radioterapia para se garantir que a dose prescrita seja realmente entregue ao paciente. Essa etapa da radioterapia é fundamental para o sucesso do tratamento, pois sem executá -lo o paciente pode ser subdosado ou sobredosado sem que o físico médico possa estimar o erro estabelecido entre a dose prescrita e dose recebida. Dentre os métodos para o controle da qualidade em radioterapia, as dosimetrias in vivo permitem determinar as doses recebidas pelo paciente durante o tratamento. Diferentes técnicas podem ser utilizadas em dosimetria in vivo, sendo uma das mais comuns a dosimetria por transmissão, que compreende a comparação entre os sinais de um dado dosímetro posicionado na entrada e na saída do paciente , nas condições de irradiação. Desta forma, o conhecimento dos espectros incidente e transmitido pelo paciente podem ser utilizados tanto para o cálculo das doses em profundidade no paciente quanto para a correção de resposta de dosímetros em dosimetrias in vivo por transmissão. O método Monte Carlo pode ser utilizado para reproduzir diversas situações desejadas em radioterapia, que pode ser tanto, em controle da qualidade como, em tratamentos, por ser uma ferramenta acurada e sem restrições físicas e financeiras. Esse trabalho se propõe a determinar a perturbação sofrida pelo feixe primário ao atravessar objetos simuladores por meio da determinação da fluência energética e da energia depositada em diferentes condições de irradiação, através do método Monte Carlo. Neste trabalho foi desenvolvida uma quantidade de situações utilizando-se o código PENELOPE para possibilitar a análise do comportamento de fluências energéticas e energias depositadas. Os parâmetros clínicos que sofreram variação para a analise foram a espessura do objeto simulador, o tamanho de campo e a distância fonte-superfície (DFS). Os resultados deste trabalho mostram que a dependência em relação a cada parâmetro clínico é diferente, como é o caso da DFS, que influência mais na resposta do que o tamanho de campo, por exemplo. Portanto, esse trabalho pode ser uma ferramenta para trabalhos posteriores no estabelecimento de protocolos de relação entre fluência e dose, bem como, de armazenamento ou aplicação de dose em pacientes. / Quality control is an essential practice in radiation oncology in order to ensure that the prescribed dose is delivered to the patient. This step of radiation therapy is very important to successful treatment, because without it the patient may receive bellow dose or over dose without the physical doctor can estimate the error established between the prescribed dose and dose received. One of the methods for quality control in radiotherapy, the in vivo dosimetry let you determine the doses received by the patient during the treatment. Different techniques can be used in vivo dosimetry, being one of the most common dosimetry for transmission, which includes the comparison of the signs of a dosimeter placed on the entrance and exit of patient irradiation conditions. In this way, the knowledge of incident spectra and transmitted by the patient can be used for both the calculation of doses in depth in the patient as to the dosimeter response in vivo dosimetry for transmission. The Monte Carlo method can be used to make a variety of situations you want in radiotherapy, and may be as much in quality as in control treatments for being a tool accurately and without physical and financial constraints. This work aims to determine the disturbance suffered by primary beam across objects simulators through determination of energy flow and energy deposited in different irradiation conditions through the Monte Carlo method. This work was developed a number of situations using the PENELOPE code to enable the analysis of the behavior of energy deposited energies and skills. The clinical parameters that have suffered the assess variation ranges were the thickness of the object Simulator, the field size and source surface distance (SSD). The results show that the dependence on each clinical parameter is different, as is the case of DFS, which most influence on response than the field size, for example. Therefore, this work can be a tool for further work on the establishment of relationship between fluency and protocols, as well as dose, dose storage in patients.
20

Caracterização de dosímetros semicondutores e suas aplicações em técnicas especializadas em radioterapia / Characterization of Semiconductors Dosimeters and their Applications in Specialized Techniques in Radiation Therapy.

Fernanda Ferretti de Oliveira 21 December 2012 (has links)
Introdução: A Radioterapia é frequentemente utilizada no tratamento do câncer, seja como uma modalidade simples ou em combinação com outras modalidades, tais como a cirurgia e a quimioterapia. Com o objetivo de eliminar células não desejadas no organismo humano, utiliza-se de radiações ionizantes para provocar a destruição de células tumorais pela absorção da energia da radiação incidente. A principal dificuldade encontrada em radioterapia é que as células tumorais não são tratadas isoladamente, isto é, o dano da radiação não é restrito somente às células tumorais, mas afeta também as células normais. Assim sendo, é essencial que a dose de radiação liberada nos tecidos normais seja tão baixa quanto possível para minimizar o risco de efeitos colaterais provocados pelos tratamentos radioterápicos. Objetivos: O objetivo deste trabalho é a caracterização de dosímetros semicondutores e dosímetros termoluminescentes e suas aplicações em técnicas não convencionais de Radioterapia. A partir da caracterização será possível a implementação dos dosímetros como sistema de dosimetria in vivo em teleterapia com feixe de fótons, visando atender as necessidades prementes do Serviço de Radioterapia do HCFMRP em implantar a técnica de irradiação de corpo inteiro e em realizar o controle de dose administrada ao paciente. Metodologia e Resultados: Diodos semicondutores foram caracterizados de acordo com o fator campo, angulação, taxa de dose, temperatura e fator bandeja, para obtenção dos fatores de correção. Verificou-se que a variação da resposta dos diodos com a temperatura, angulação e taxa de dose não foi significativa. Fatores campo foram calculados e registrados para campos de 3x3 cm 2 a 40x40cm 2 , onde se observou aumento na leitura do diodo com o aumento no campo. A resposta com a taxa de dose apr esentou pouca variação (de 100cGy/min para 300cGy/min a variação foi menor que 1,2%). O fator bandeja encontrado foi de 0,95±0,01 demonstrando que a presença da bandeja provoca diminuição na resposta do detector. Após a caracterização, os diodos foram calibrados em setup TBI para determinação dos fatores de calibração para cada espessura simulada do paciente (DLL). A dosimetria in vivo foi realizada em 3 pacientes submetidos ao tratamento de TBI do HCFMRP. A diferença percentual máxima entre as medidas com diodo e o valor nominal de dose foi de 3,6%, o que está de acordo com o recomendado pelo ICRU (+/- 5%). Os resultados demonstram a viabilidade e confiabilidade da técnica de dosimetria com diodos semicondutores para Controle de Qualidade de dose em tratamento de TBI. Ainda, dosímetros termoluminescentes foram caracterizados quanto à homogeneidade do grupo e a linearidade. Os fatores de calibração individuais foram encontrados e os dosímetros foram aplicados em simulações em setup TBI. Os cálculos de dose das simulações realizadas com os termoluminescentes inseridos nos orifícios de um OSA demonstraram concordância com os valores nominais de dose. Para as regiões do tórax superior e inferior, onde os TLD receberam doses mais elevadas (>150cGy), recomendou-se a utilização de compensadores de dose, para a prática clínica.Uma câmara de ionização foi utilizada como dosímetro de referência em todas as etapas de calibração e caracterização dos diodos e termoluminescentes. Conclusões: Este estudo mostrou que, para tratamentos de irradiação de corpo inteiro, quando o paciente estiver sendo preparado para um transplante de medula óssea, e o planejamento necessitar de uma grande eficácia na distribuição de dose, a metodologia com aplicações de dosímetros semicondutores apresenta-se como uma alternativa viável, precisa e de grande importância para o controle dosimétrico. Assim, ficou evidenciada a importância da utilização do diodo para o Controle de Qualidade, na avaliação da dos e a ser ministrada ao paciente, pelo menos em toda primeira fração de tratamento de TBI. Além disso, ficou demonstrada a aplicabilidade dos dosímetros termoluminescentes para controle dosimétrico, demonstrando o valor da dosimetria termoluminescente como um sistema de verificação de dose e sua eficácia como parte de um programa de garantia de qualidade em Radioterapia. A caracterização dos termoluminescentes evidenciou a possibilidade de aplicação da técnica TL em dosimetria in vivo. / Introduction: Radiation therapy is often used in cancer treatment, either as a single modality or in combination with other modalities, such as surgery and chemotherapy. Aiming to eliminate unwanted cells in the human body, radiation therapy uses ionizing radiation to cause destruction of tumor cells by absorbing the energy of the incident radiation. The main difficulty in radiation therapy is that tumor cells are not separately treated. The radiation damage is not restricted solely to tumor cells, but also affects normal cells. Therefore, it is essential that the radiation dose released in normal tissues is as low as possible to minimize the risk of side effects caused by radiotherapy treatments. Objectives: The objective of this work is the characterization of semiconductor dosimeters and thermoluminescent dosimeters and their applications in non -conventional radiotherapy techniques. After characterization it will be possible to implement the dosimeters as a system of in vivo dosimetry in radiotherapy with photon beam, to meet the pressing needs of the Radiotherapy Service of HCFMRP in deploying the technique of total body irradiation and make the control of dose administered to the patient . Methodology and Results: Semiconductor diodes were characterized according to the field factor, angle, dose rate, temperature and tray factor to obtain the correction factors. It was found that the variation of the response of the diodes with temperature, angle and dose rate was not significant. Field factors were calculated and recorded for fields from 3x3 cm 2 to 40x40cm 2 , wher e there was an increase in the reading of the diode with increasing field. The response with dose rate showed small variation (from 100cGy/min to 300cGy/min the variation was less than 1.2%). The tray factor was 0.95 ± 0.01 demonstrating that the tray decreases detector response. After characterization, the diodes were calibrated in TBI setup for determining the calibration factors for each simulated patient thickness (latero-lateral distance). The in vivo dosimetry was performed in 3 patients undergoing TBI treatment in HCFMRP. The maximum percentage difference between the measurements and the diode nominal dose was 3.6%, which is consistent with that recommended by ICRU (+ / - 5%). The results demonstrate the feasibility and reliability of the dosimetry technique with semiconductor diodes for dose quality control in TBI treatments. Still, dosimeters were characterized by group homogeneity and linearity. The calibration factors were found and individual dosimeters were applied in simulations with TBI setup. The dose calculation of simulations performed with the thermoluminescent inserted in holes of the phantom showed agreement with the nominal dose. For regions of the upper and lower thorax where TLD received higher doses (> 150cGy) it was recommended the use of compensating dose in clinic. An ionization chamber dosimeter was used as reference in all stages of calibration and characterization of diodes and thermoluminescents. Conclusions: This study showed that, for total body irradiation treatments, when the patient is being prepared for a bone marrow transplant, and planning requires a great effect on the dose distribution, the methodology with semiconductor dosimeters presented a viable alternative, and has great importance for the dosimetric control. The study proved the importance of diode semiconductors for quality control, for evaluation of the dose to be administered to the patient, at least throughout the first fraction of TBI treating. Furthermore, it was demonstrated the applicability of TLD for control quality, demonstrating the value of thermoluminescent dosimetry as a dose verification system and its effectiveness as part of a program of quality assurance in radiotherapy. The characterization of thermoluminescent showed the possibility of applying the TL technique in in vivo dosimetry.

Page generated in 0.2 seconds