• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • 2
  • Tagged with
  • 12
  • 12
  • 8
  • 8
  • 7
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estudo de técnicas de controle de máquinas de relutância chaveada para aplicações em sistemas de acionamentos com velocidade variável

Almeida, Lucas Alves de 27 February 2018 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2018-05-25T12:16:21Z No. of bitstreams: 1 lucasalvesdealmeida.pdf: 7514122 bytes, checksum: a0029ec07180541f754e98112ec47b6b (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2018-06-14T11:52:17Z (GMT) No. of bitstreams: 1 lucasalvesdealmeida.pdf: 7514122 bytes, checksum: a0029ec07180541f754e98112ec47b6b (MD5) / Made available in DSpace on 2018-06-14T11:52:17Z (GMT). No. of bitstreams: 1 lucasalvesdealmeida.pdf: 7514122 bytes, checksum: a0029ec07180541f754e98112ec47b6b (MD5) Previous issue date: 2018-02-27 / Sistemas eletromecânicos são de grande importância atualmente, e a procura por maior eficiência e desempenho aliados a um menor custo justificam a busca por alternativas tanto em topologia quanto no controle e acionamento de tais sistemas. A máquina de relutância chaveada é capaz de cumprir estes requisitos e tem despertado o interesse de pesquisadores e empresas nos últimos anos, emergindo como uma alternativa viável em diversas aplicações. Porém, esta máquina possui características singulares. Por conta de sua estrutura duplamente saliente, seu funcionamento correto depende da aplicação de pulsos de corrente por determinados intervalos de tempo, e na sequência correta, seus parâmetros são variáveis no tempo, apresentando um comportamento com características não-lineares. Tais particularidades fazem com que seja difícil controlar o torque destas máquinas, as quais possuem a tendência de apresentar altas oscilações durante a mudança da excitação de cada fase. Este trabalho tem por objetivo contribuir com o estudo da modelagem e do acionamento de uma máquina de relutância chaveada. É apresentada sua modelagem matemática e um modelo de simulação que leva em consideração as não linearidades existentes. Em seguida são apresentadas técnicas de controle de corrente que incluem um regulador de histerese, um controlador PI e um controlador por modos deslizantes. Também é utilizado um método capaz de determinar o momento em que cada fase deve ser acionada, baseado no ângulo do rotor, e uma técnica de variação dos ângulos de acionamento de maneira dinâmica, usados em conjunto com os controladores propostos. O trabalho também caracteriza e apresenta as funções de divisão de torque como uma maneira de reduzir drasticamente as oscilações de torque. São apresentadas as operações como motor e como gerador, bem como um exemplo de aplicação de modo a ilustrar ambos os modos de operação. / Electromechanical systems have a huge relevance nowadays, and seeking for improvements in efficiency and performance at the lowest cost make valid to identify topological and control alternatives of these systems. The switched reluctance machine is capable to fulfill such requirements and emerges as an interesting field of research. Academics and industrial works shows that it is a promising alternative in several applications. However, this machine presents unique characteristics, like the doubly salient structure, the necessity to apply phase currents in a sequence determined by the stator/rotor pole ratio, its time variantparameters,andthestrongnonlinearcharacteristics. Suchsingularitiesmaketorque control hard, as it tends to present high ripples and makes a lot of noise. This thesis aims to contribute on switched reluctance machine modeling and drive system. A mathematical model is presented, and also a simulation model that accounts for nonlinearities, making possible to simulate the machine accurately in a computational environment. A hysteresis regulator, a PI controller and a sliding mode controller are designed and simulated. An algorithm to determine when each phase should be excited based on rotor angle is used, and a technique to change such firing angles dynamically is developed that can be used along with current control methods presented. The work also defines and presents torque sharing functions as a way to greatly reduce torque ripple. Motor and generator operation are contemplated, and both modes are illustrated in an application example.
12

[pt] CONTROLE DO INVERSOR DE UMA USINA FOTOVOLTAICA PARA MELHORA DA ESTABILIDADE TRANSITÓRIA DE UMA MÁQUINA SÍNCRONA / [en] PROPOSED INVERTER CONTROL OF A PHOTOVOLTAIC GENERATION UNIT FOR THE IMPROVEMENT OF THE TRANSIENT STABILITY OF A SYNCHRONOUS MACHINE

OSCAR CUARESMA ZEVALLOS 08 April 2021 (has links)
[pt] O incremento de geração fotovoltaica de grande porte traz consideráveis mudanças nas características operativas e dinâmicas do sistema quando este é submetido a grandes distúrbios. Um dos problemas técnicos mais relevantes é a estabilidade transitória, já que a geração intermitente ligada ao sistema por conversores eletrônicos não contribui para o aumento da inércia total do sistema. Entretanto, os conversores eletrônicos podem, potencialmente, trazer novas oportunidades de controle rápido para dar suporte aos geradores síncronos em resposta a um distúrbio severo. No presente trabalho propõe uma estratégia de controle para inversores fotovoltaicos baseado na injeção da corrente com um grande impacto na resposta transitória do ângulo do rotor da máquina síncrona, identificada através da análise de sensibilidade dos autovalores e dos fatores de participação. Ao fazer isso, é possível aumentar a potência ativa da máquina síncrona próximo do seu valor pré-falta, reduzindo o desequilíbrio entre o torque elétrico e mecânico. A estratégia de controle proposta foi testada experimentalmente, utilizando um inversor e uma montagem máquina síncrona-motor e, através da simulação de um sistema híbrido com um sistema fotovoltaico de grande porte. Os resultados mostram que a estratégia de controle proposta não está apenas em conformidade com os requisitos dos código da rede para melhorar a estabilidade da tensão durante uma perturbação grave, mas também é capaz de manter a estabilidade transitória da rede provando, assim, ser uma melhor alternativa em relação à capacidade FRT requerida pelos códigos de rede. / [en] The increase in photovoltaic generation has caused changes in the power system s operative and dynamic characteristics when subjected to severe disturbances. One of the most relevant problems associated with this renewable energy source is the transient stability, as renewable generation connected to the system by electronic converters does not contrinute to the increase of the total inertia of the system. However, electronic converters can potentially bring new opportunities for rapid control to support synchronous generators in response to severe disturbance. The present work proposes a control strategy for photovoltaic inverters based on the injection of the current with a major impact on the transient response of the synchronous machine rotor angle, identified through the eigenvalue sensitivity analysis and the participation factors. By doing so, it is possible to increase the synchronous machine active power output close to its pre-fault value, reducing the disequilibrium between mechanical and electrical torque. The proposed control strategy was experimentally tested using an inverter and a synchronous-motor machine assembly and, by simulating a hybrid system with a large photovoltaic system. The results show that the proposed control strategy not only conforms to the grid codes requirements to improve voltage stability during a severe disturbance, but is also able to maintain transient stability thus proving to be a better alternative to the FRT capability required by the grid codes.

Page generated in 0.191 seconds