• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • Tagged with
  • 9
  • 9
  • 9
  • 7
  • 7
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Inverter five levels based on switching cell multi-state type T / Inversor de cinco nÃveis baseado na cÃlula de comutaÃÃo de mÃltiplos estados tipo T

Ronny Glauber de Almeida Cacau 30 January 2014 (has links)
Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgico / Este trabalho apresenta o estudo, projeto e implementaÃÃo de um inversor multinÃvel monofÃsico baseado na cÃlula de comutaÃÃo de mÃltiplos estados tipo T (5L-CCME-T2) para aplicaÃÃes em baixa tensÃo e elevadas correntes. A topologia proposta visa estender a aplicaÃÃo da cÃlula de comutaÃÃo de mÃltiplos estados (CCME) para a estrutura do conversor de trÃs nÃveis tipo T, proporcionando cinco nÃveis na tensÃo de saÃda antes do filtro e, consequentemente, uma reduÃÃo do conteÃdo harmÃnico e maior qualidade da tensÃo de saÃda. Outra caracterÃstica desta topologia à a distribuiÃÃo uniforme da corrente total de saÃda entre os semicondutores do conversor, proporcionando menores perdas por conduÃÃo e elevado rendimento. AlÃm disso, à possÃvel reduzir o peso e volume dos magnÃticos, uma vez que a frequÃncia de operaÃÃo dos elementos reativos à o dobro da frequÃncia de comutaÃÃo dos interruptores. Um estudo teÃrico com anÃlise qualitativa e quantitativa do inversor proposto e metodologia de projeto foi realizado. A estratÃgia de controle implementada tem como objetivo o controle da tensÃo de saÃda e das tensÃes do barramento CC. A tÃcnica de modulaÃÃo empregada à a convencional modulaÃÃo por largura de pulso senoidal (SPWM). A validaÃÃo da topologia à realizada atravÃs dos resultados de simulaÃÃo e experimentais de um protÃtipo desenvolvido para uma potÃncia de saÃda de 5 kW. / This work presents the study, design and implementation of a multilevel converter based on T - type multi - state switching cell (5L - MSSC - T 2 ) for applications in low voltages and high currents. The proposed topology aims to extend the application of the multi - state switching cell (MSSC) to the structure of the three - level T - type converter, providing five levels in the output voltage before the filter and, consequently, a reduction of the harmonic content and higher output vol tage quality. Another feature of this topology is the uniform distribution of the total output current between the semiconductors of the converter, providing lower conduction losses and high efficiency. Furthermore , it is possible to reduce the weight and volume of magnetics, since the operating frequency of reactive elements is twice the switching frequency of the switches. A theoretical study with qualitative and quantitative analysis of the proposed inverter and the design methodology was performed . The control strategy implemented aims to control the output voltage and the DC bus voltages. The employed modulation technique is the conventional sinusoidal pulse width modulation (SPWM) . The validation of the topology is verified through simulation and exper imental results of a developed prototype for an output power of 5 kW
2

Análise de técnicas de detecção de ilhamento ativas em sistemas de geração distribuída baseados em inversores fonte de tensão / Analysis of active islanding detection techniques in distributed generation systems based on voltage source inverters

Carvalho, Marina Silva Camillo de 23 March 2017 (has links)
A abordagem principal desse trabalho é o estudo de técnicas anti-ilhamento ativas com realimentação positiva em um sistema de Geração Distribuída (GD) composto por um Inversor Fonte de Tensão (VSI,do inglês Voltage Source Inverter) e com cargas locais conectadas em paralelo. Na literatura são encontrados dois grupos de técnicas empregadas como proteção anti-ilhamento: as ativas e as passivas. Os métodos de detecção de ilhamento ativos são utilizados, pois possuem menores zonas de não detecção em comparação às técnicas passivas, porém injetam distúrbios contínuos no sistema de GD. Esses distúrbios degradam a qualidade de energia elétrica fornecida pelo conversor eletrônico. Nesse contexto, como escopo dessa dissertação, é realizado o estudo da estrutura de controle empregada no sistema de GD conectado com a rede de distribuição, com o intuito de avaliar o funcionamento do gerenciamento de tensão e de potência ativa e reativa. E em seguida, são discutidas técnicas de detecção de ilhamento ativas em frequência e tensão, ambas, com realimentação positiva e ganho fixo com o objetivo de investigar o desempenho das mesmas em relação ao tempo de detecção e a injeção de distúrbios no sistema de controle da GD. A partir dessa análise, são desenvolvidas técnicas anti-ilhamento com intuito de reduzir a injeção de distúrbios em diferentes pontos de operação da GD e garantir uma eficiência semelhante aos métodos tradicionais em casos de difícil detecção. Essas técnicas são baseadas na implementação do cálculo de um ganho com realimentação positiva variável inversamente proporcional a variação de potência ativa ou reativa entregue a rede. Para validação das propostas presentes nesta dissertação, são obtidos resultados em simulações computacionais e, posteriormente são adquiridos resultados práticos através de uma bancada experimental compatível com o sistema de GD simulado. / The main approach of this thesis is the study of active anti-islanding techniques with positive feedback in a Distributed Generation (DG) system composed by a Voltage Source Inverter (VSI) and local loads. In literature two groups of techniques are used as anti-island protection: the active and the passive techniques. The active islanding detection methods are preferably used because of the smaller non-detection zones compared to passive techniques, however they inject continuous disturbances in the DG system, reducing the power quality provided by the VSI. In this context, as the scope of this dissertation, it is firstly carried out the study of control structures employed in grid-tied distribution system, to evaluate the operation of the voltage control loops, and the active-and reactive power managements. Additionally, we discuss active islanding detection techniques in frequency and voltage with positive feedback and constant gain, based on the classical, with the objective of investigating their performance in relation to the detection time and the injection of disturbances in the DG system. From this analysis, antiislanding techniques are developed to guarantee efficiency similar to the traditional methods in cases of small-power flow through the grid and minimize disturbances. These techniques are based on the calculation of the positive feedback variable gain inversely proportional to the deviation of active or reactive power delivered or absorbed from the grid. To validate this proposal, the results are obtained through computational simulations and experimental analysis, as well.
3

Análise de técnicas de detecção de ilhamento ativas em sistemas de geração distribuída baseados em inversores fonte de tensão / Analysis of active islanding detection techniques in distributed generation systems based on voltage source inverters

Marina Silva Camillo de Carvalho 23 March 2017 (has links)
A abordagem principal desse trabalho é o estudo de técnicas anti-ilhamento ativas com realimentação positiva em um sistema de Geração Distribuída (GD) composto por um Inversor Fonte de Tensão (VSI,do inglês Voltage Source Inverter) e com cargas locais conectadas em paralelo. Na literatura são encontrados dois grupos de técnicas empregadas como proteção anti-ilhamento: as ativas e as passivas. Os métodos de detecção de ilhamento ativos são utilizados, pois possuem menores zonas de não detecção em comparação às técnicas passivas, porém injetam distúrbios contínuos no sistema de GD. Esses distúrbios degradam a qualidade de energia elétrica fornecida pelo conversor eletrônico. Nesse contexto, como escopo dessa dissertação, é realizado o estudo da estrutura de controle empregada no sistema de GD conectado com a rede de distribuição, com o intuito de avaliar o funcionamento do gerenciamento de tensão e de potência ativa e reativa. E em seguida, são discutidas técnicas de detecção de ilhamento ativas em frequência e tensão, ambas, com realimentação positiva e ganho fixo com o objetivo de investigar o desempenho das mesmas em relação ao tempo de detecção e a injeção de distúrbios no sistema de controle da GD. A partir dessa análise, são desenvolvidas técnicas anti-ilhamento com intuito de reduzir a injeção de distúrbios em diferentes pontos de operação da GD e garantir uma eficiência semelhante aos métodos tradicionais em casos de difícil detecção. Essas técnicas são baseadas na implementação do cálculo de um ganho com realimentação positiva variável inversamente proporcional a variação de potência ativa ou reativa entregue a rede. Para validação das propostas presentes nesta dissertação, são obtidos resultados em simulações computacionais e, posteriormente são adquiridos resultados práticos através de uma bancada experimental compatível com o sistema de GD simulado. / The main approach of this thesis is the study of active anti-islanding techniques with positive feedback in a Distributed Generation (DG) system composed by a Voltage Source Inverter (VSI) and local loads. In literature two groups of techniques are used as anti-island protection: the active and the passive techniques. The active islanding detection methods are preferably used because of the smaller non-detection zones compared to passive techniques, however they inject continuous disturbances in the DG system, reducing the power quality provided by the VSI. In this context, as the scope of this dissertation, it is firstly carried out the study of control structures employed in grid-tied distribution system, to evaluate the operation of the voltage control loops, and the active-and reactive power managements. Additionally, we discuss active islanding detection techniques in frequency and voltage with positive feedback and constant gain, based on the classical, with the objective of investigating their performance in relation to the detection time and the injection of disturbances in the DG system. From this analysis, antiislanding techniques are developed to guarantee efficiency similar to the traditional methods in cases of small-power flow through the grid and minimize disturbances. These techniques are based on the calculation of the positive feedback variable gain inversely proportional to the deviation of active or reactive power delivered or absorbed from the grid. To validate this proposal, the results are obtained through computational simulations and experimental analysis, as well.
4

Sistema de fornecimento de potência a partir de célula a combustível utilizando conversor estático com modulação delta modificada / Power supply system from fuel cell using static converter with modified delta modulation

Gongora, Vicente de Lima 19 April 2017 (has links)
Este trabalho, constitui-se em uma contribuição para o estudo das estratégias de mo-dulação direta baseadas em histerese e que funcionam em frequência fixa de comutação. Tem como objetivo principal propor a estratégia delta modificada, que diferencia-se na forma de ajuste da largura de banda de histerese, alterando-se seus limites e em como executa o comando de bloqueio das chaves de potência, para que a corrente de saída se mantenha em frequência fixa de operação e apresente rápida resposta dinâmica no sistema controlado. Para tanto, não necessita da utilização de derivadas, nem de uma corrente média de referência, tão pouco, se utiliza dos tempos de comutação. A estratégia proposta, comprova que é possível produzir os adequados pulsos de comando para o processamento da energia proveniente de célula combustível, através do conversor estático de potência, utilizando-se, principalmente, dos valores de ultrapassagem nos limites estabelecidos de histerese. Como objetivo secundário desta pesquisa, desenvolve-se um conversor CC/CC auxiliar para adaptar e estabilizar a energia proveniente da CAC, compondo-se um sistema útil que serve de base para fornecer energia, aos mais diversos tipos de cargas em CC. Além disso, apresenta-se uma revisão das estratégias de modulação em modo direto para o controle da corrente de saída no conversor estático, tendo como base a tensão nos terminais de um indutor. Contudo, outras estratégias são naturalmente citadas, no transcorrer deste trabalho, devido haver combinações entre as diferentes estratégias moduladoras e controladoras comentadas. / This work, is a contribution to the study of direct modulation strategies based on hysteresis and that operate at fixed switching frequency. Its main objective is to propose the modified delta strategy, which differentiates from the others strategies in the form of adjustment of hysteresis bandwidth, changing its limits and in executing the locking command of the power keys, so that the output current is maintain at fixed frequency of operation and a rapid dynamic response in the controlled system. In order to do so, it does not require the use of derivatives or a reference average current and also the switching times are not used. This strategy shows that it is possible to produce the appropriate command pulses for the processing of fuel cell energy by the static power converter using mainly the exceedance limit values. As a secondary objective of this research, an auxiliary DC/DC converter is developed to adapt and stabilize the energy coming from the fuel cell, forming a useful system that serves as a base to supply power to the most diverse types of DC loads. In addition, we present a review of the direct-mode modulation strategies for the control of the output current in the static converter, updating data, and based on the voltage at the terminals of an inductor; how-ever, others strategies are naturally cited because there are combinations between the different modulating strategies and controllers commented on in the course of this work.
5

Estudo e análise de algoritmos de detecção de ilhamento em sistemas de geração distribuída conectados à rede de distribuição / Study and analysis of anti-Islanding algorithms used in distributed generation systems connected to the grid

Aguiar, Cassius Rossi de 11 October 2013 (has links)
Este trabalho aborda a detecção da condição de ilhamento e de seus impactos em redes de distribuição e em gerações distribuídas que empregam conversores CC-CA. Na literatura são encontradas dois grupos de técnicas para este tipo de aplicação. As técnicas passivas, que identificam a condição de ilhamento através do ajuste dos limites de variação dos relés de proteção, e as técnicas ativas, que inserem um sinal de realimentação positiva de forma a tornar o sistema instável no momento da desconexão. As técnicas ativas, por apresentarem um menor tempo de detecção e simples implementação em hardware, são preferencialmente utilizadas, apesar da injeção de distúrbios no sistema de controle da geração distribuída. O estado-da-arte em termos de detecção de ilhamento consiste em desenvolver uma técnica que possua alta capacidade de detecção, porém sem injeção de distúrbios no sistema de geração distribuída quando conectado à rede de distribuição. Neste trabalho, são abordadas duas formas para a redução da injeção de distúrbios e do tempo de detecção. Em uma primeira abordagem é proposto um projeto ótimo para o algoritmo de sincronização PLL (phase-locked loop), o qual permite a redução do ganho de realimentação positiva para técnicas em frequência e, consequentemente, a redução da injeção de distúrbios. Em uma segunda abordagem é utilizada a metodologia fuzzy de forma a garantir a detecção da condição de ilhamento sem nenhuma injeção de distúrbios no sistema de controle. Resultados de simulação e experimentais, obtidos por meio de uma bancada experimental controlada por DSP, são apresentados para validar as propostas presentes nesta dissertação / This thesis deals with the islanding detection and its impact on distribution networks when distributed generation systems are driven by DC-AC converters. Two groups of techniques are found in the literature. The passive techniques in which adjusting the variation limits of protective relays identify the islanding condition, and the active techniques that insert a positive feedback signal in order to make the system unstable when the contingency is on progress. The active techniques present a reduced detection time and simple hardware implementation. They are preferably used in despite of the injection of disturbances in the control system. In this thesis two ways to reduce injection of disturbances and detection time are proposed. In a first approach is shown an optimal design for the synchronization algorithm PLL (Phase-Locked Loop) which allows to reduce the positive feedback gain in frequency techniques in order to decrease the injection of disturbances. In a second approach a fuzzy methodology is used to ensure the islanding detection with the aforementioned requirements. Simulation analysis and experimental results are presented to validate the proposed approach
6

Estudo e análise de algoritmos de detecção de ilhamento em sistemas de geração distribuída conectados à rede de distribuição / Study and analysis of anti-Islanding algorithms used in distributed generation systems connected to the grid

Cassius Rossi de Aguiar 11 October 2013 (has links)
Este trabalho aborda a detecção da condição de ilhamento e de seus impactos em redes de distribuição e em gerações distribuídas que empregam conversores CC-CA. Na literatura são encontradas dois grupos de técnicas para este tipo de aplicação. As técnicas passivas, que identificam a condição de ilhamento através do ajuste dos limites de variação dos relés de proteção, e as técnicas ativas, que inserem um sinal de realimentação positiva de forma a tornar o sistema instável no momento da desconexão. As técnicas ativas, por apresentarem um menor tempo de detecção e simples implementação em hardware, são preferencialmente utilizadas, apesar da injeção de distúrbios no sistema de controle da geração distribuída. O estado-da-arte em termos de detecção de ilhamento consiste em desenvolver uma técnica que possua alta capacidade de detecção, porém sem injeção de distúrbios no sistema de geração distribuída quando conectado à rede de distribuição. Neste trabalho, são abordadas duas formas para a redução da injeção de distúrbios e do tempo de detecção. Em uma primeira abordagem é proposto um projeto ótimo para o algoritmo de sincronização PLL (phase-locked loop), o qual permite a redução do ganho de realimentação positiva para técnicas em frequência e, consequentemente, a redução da injeção de distúrbios. Em uma segunda abordagem é utilizada a metodologia fuzzy de forma a garantir a detecção da condição de ilhamento sem nenhuma injeção de distúrbios no sistema de controle. Resultados de simulação e experimentais, obtidos por meio de uma bancada experimental controlada por DSP, são apresentados para validar as propostas presentes nesta dissertação / This thesis deals with the islanding detection and its impact on distribution networks when distributed generation systems are driven by DC-AC converters. Two groups of techniques are found in the literature. The passive techniques in which adjusting the variation limits of protective relays identify the islanding condition, and the active techniques that insert a positive feedback signal in order to make the system unstable when the contingency is on progress. The active techniques present a reduced detection time and simple hardware implementation. They are preferably used in despite of the injection of disturbances in the control system. In this thesis two ways to reduce injection of disturbances and detection time are proposed. In a first approach is shown an optimal design for the synchronization algorithm PLL (Phase-Locked Loop) which allows to reduce the positive feedback gain in frequency techniques in order to decrease the injection of disturbances. In a second approach a fuzzy methodology is used to ensure the islanding detection with the aforementioned requirements. Simulation analysis and experimental results are presented to validate the proposed approach
7

Análise e projeto do conversor fonte-y para uso em sistemas de geração de energia fotovoltaica de baixa tensão / Analysis and design of the y-source converter for use in low-voltage photovoltaic generation systems

Martins, Alex de Sá 26 October 2017 (has links)
Submitted by Alex de Sá Martins null (lex.martins@hotmail.com) on 2017-12-16T23:31:27Z No. of bitstreams: 1 ANÁLISE E PROJETO DO CONVERSOR FONTE-Y PARA USO....pdf: 2723184 bytes, checksum: 9e77f24832992941e605e87a84c25d1a (MD5) / Approved for entry into archive by Maria Marlene Zaniboni null (zaniboni@bauru.unesp.br) on 2017-12-18T12:51:16Z (GMT) No. of bitstreams: 1 martins_as_me_bauru.pdf: 2723184 bytes, checksum: 9e77f24832992941e605e87a84c25d1a (MD5) / Made available in DSpace on 2017-12-18T12:51:16Z (GMT). No. of bitstreams: 1 martins_as_me_bauru.pdf: 2723184 bytes, checksum: 9e77f24832992941e605e87a84c25d1a (MD5) Previous issue date: 2017-10-26 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Este trabalho aborda o estudo de topologia de conversor de energia baseada no uso de configuração de rede de impedância denominada fonte-Y, com o objetivo de ser aplicado em sistemas de geração distribuída de energia, em redes de baixa tensão. Em sistemas de geração distribuída de energia usualmente se faz necessária a existência de um estágio elevador de tensão e um estágio inversor, ambos controlados para produzir tensão e/ou corrente senoidal com mesma frequência, amplitude e fase da rede elétrica. Nesse sentido, este trabalho propõe a aplicação do conversor fonte- Y entre a geração e a conexão com e rede elétrica, de forma que as ações de conversão relacionadas com a elevação (CC-CC) e inversão (CC-CA) sejam efetuadas de forma integrada por uma única estrutura, contribuindo com a possibilidade de melhoria no rendimento global devido à minimização de estágios de conversão em cascata. Inicialmente, é efetuado um levantamento bibliográfico relacionando as principais topologias de conversores utilizando redes de impedância com indutores acoplados, considerando os aspectos operacionais, arranjo de impedância e ganho estático idealizado, desprezando perdas entre tensão de entrada e tensão máxima de saída obtida. Segue-se o estudo da operação de conversor CCCC empregando rede de impedância do tipo Y, definição das equações que regem o comportamento no tempo das tensões e correntes nos capacitores e indutores. É feita uma avaliação comparativa do ganho estático de tensão obtido e dos esforços nos semicondutores em função das variáveis de controle de projeto e operação disponíveis. Prossegue-se com o estudo da operação do conversor CC-CA empregando rede de impedância do tipo Y, considerando extensão das expressões encontradas para a operação como conversor CC-CC. Por fim, simulações computacionais foram desenvolvidas no ambiente PSIM contemplando o emprego dos circuitos e estratégias de modulação relacionadas com aplicações do conversor fonte- Y, em operação CC-CC e operação CC-CA visando a integração em sistemas de geração de energia, para demonstrar as vantagens e desvantagens do uso dessa topologia. / This paper deals with the study of energy converter topology based on the use of impedance network configuration called Y-source, with the objective of being applied in photovoltaic energy cogeneration systems in low voltage grids. In photovoltaic energy generation systems, it is usually necessary to have a voltage boost stage and an inverter stage, both controlled to produce voltage and / or sine current with the same frequency, amplitude and phase of the power grid. In this sense, this work proposes the application of the Y-source converter between the photovoltaic generation and the connection with the electric grid, so that the conversion actions related to elevation (DC-DC) and inversion (DC-AC) in a way integrated by a single structure, contributing to the possibility of improvement in the overall yield due to the minimization of cascade conversion stages. Initially a bibliographical survey was performed relating the main inverter topologies using impedance networks with coupled inductors considering the operational aspects, impedance arrangement and ideal static gain between the input voltage and the maximum output obtained. ext, the study of the DC-DC converter operation using the Y-type impedance network, definition of the equations governing the time behavior of the voltages and currents in the capacitors and inductors, is presented. It is also done the comparative evaluation of the static voltage gain obtained and the stresses in the semiconductors according to the available control and design control variables. Study of the operation of the DC-AC converter employing type Y impedance network, considering the extension of the expressions found for the operation as DC-DC converter. Finally, computational simulations were developed in the PSIM environment, considering the use of circuits and modulation strategies related to Y-source converter applications, in DC-DC operation and DC-AC operation for integration into power cogeneration systems, to demonstrate advantages and disadvantages of using this topology. / 134173/2017-1
8

Conversor CC/CA de alta freq??ncia baseado em inversores ressonantes com comuta??o seq?encial para excita??o de uma tocha indutiva a plasma t?rmico

Dubut, Jean Paul 15 July 2010 (has links)
Made available in DSpace on 2014-12-17T14:54:55Z (GMT). No. of bitstreams: 1 JeanPD_TESE.pdf: 2551926 bytes, checksum: 0cea6096dad85829234a17d89574bd1e (MD5) Previous issue date: 2010-07-15 / This work describes the study, the analysis, the project methodology and the constructive details of a high frequency DC/AC resonant series converter using sequential commutation techniques for the excitation of an inductive coupled thermal plasma torch. The aim of this thesis is to show the new modulation technique potentialities and to present a technological option for the high-frequency electronic power converters development. The resonant converter operates at 50 kW output power under a 400 kHz frequency and it is constituted by inverter cells using ultra-fast IGBT devices. In order to minimize the turn-off losses, the inverter cells operates in a ZVS mode referred by a modified PLL loop that maintains this condition stable, despite the load variations. The sequential pulse gating command strategy used it allows to operate the IGBT devices on its maximum power limits using the derating and destressing current scheme, as well as it propitiates a frequency multiplication of the inverters set. The output converter is connected to a series resonant circuit constituted by the applicator ICTP torch, a compensation capacitor and an impedance matching RF transformer. At the final, are presented the experimental results and the many tests achieved in laboratory as form to validate the proposed new technique / Este trabalho descreve o estudo, a an?lise, a metodologia de projeto e os detalhes de constru??o de um conversor ressonante CC/CA de alta freq??ncia usando t?cnicas de comuta??o seq?encial (sequential pulse gating), para a excita??o de uma tocha indutiva a plasma t?rmico. Esta tese objetiva mostrar a potencialidade desta nova t?cnica de modula??o e apresentar uma alternativa tecnol?gica para o projeto de conversores eletr?nicos de pot?ncia em altas freq??ncias. O conversor ressonante opera na freq??ncia nominal de 400 kHz, com pot?ncia de 50 kW, e ? constitu?do por c?lulas inversoras empregando chaves IGBTs de comuta??o r?pida. Para minimizar as perdas de comuta??o no corte, as c?lulas ressonantes operam no modo de chaveamento suave ZVS, referenciado por uma malha PLL modificada que mant?m esta condi??o est?vel apesar das varia??es de carga. A estrat?gia de comando por comuta??o seq?encial permite operar os dispositivos IGBTs no seu limite superior de pot?ncia usando as propriedades de redu??o (derating) e de al?vio (destressing) de corrente, assim como propicia um efeito de multiplica??o na freq??ncia final do conjunto de inversores. A sa?da do conversor ? conectada a um circuito ressonante s?rie formado pelo aplicador da tocha ICTP e um capacitor de compensa??o, por interm?dio de um transformador RF de adapta??o de imped?ncias. No final, s?o apresentados resultados experimentais e ensaios conduzidos em laborat?rio como forma de validar a nova t?cnica proposta
9

Sistema de fornecimento de potência a partir de célula a combustível utilizando conversor estático com modulação delta modificada / Power supply system from fuel cell using static converter with modified delta modulation

Vicente de Lima Gongora 19 April 2017 (has links)
Este trabalho, constitui-se em uma contribuição para o estudo das estratégias de mo-dulação direta baseadas em histerese e que funcionam em frequência fixa de comutação. Tem como objetivo principal propor a estratégia delta modificada, que diferencia-se na forma de ajuste da largura de banda de histerese, alterando-se seus limites e em como executa o comando de bloqueio das chaves de potência, para que a corrente de saída se mantenha em frequência fixa de operação e apresente rápida resposta dinâmica no sistema controlado. Para tanto, não necessita da utilização de derivadas, nem de uma corrente média de referência, tão pouco, se utiliza dos tempos de comutação. A estratégia proposta, comprova que é possível produzir os adequados pulsos de comando para o processamento da energia proveniente de célula combustível, através do conversor estático de potência, utilizando-se, principalmente, dos valores de ultrapassagem nos limites estabelecidos de histerese. Como objetivo secundário desta pesquisa, desenvolve-se um conversor CC/CC auxiliar para adaptar e estabilizar a energia proveniente da CAC, compondo-se um sistema útil que serve de base para fornecer energia, aos mais diversos tipos de cargas em CC. Além disso, apresenta-se uma revisão das estratégias de modulação em modo direto para o controle da corrente de saída no conversor estático, tendo como base a tensão nos terminais de um indutor. Contudo, outras estratégias são naturalmente citadas, no transcorrer deste trabalho, devido haver combinações entre as diferentes estratégias moduladoras e controladoras comentadas. / This work, is a contribution to the study of direct modulation strategies based on hysteresis and that operate at fixed switching frequency. Its main objective is to propose the modified delta strategy, which differentiates from the others strategies in the form of adjustment of hysteresis bandwidth, changing its limits and in executing the locking command of the power keys, so that the output current is maintain at fixed frequency of operation and a rapid dynamic response in the controlled system. In order to do so, it does not require the use of derivatives or a reference average current and also the switching times are not used. This strategy shows that it is possible to produce the appropriate command pulses for the processing of fuel cell energy by the static power converter using mainly the exceedance limit values. As a secondary objective of this research, an auxiliary DC/DC converter is developed to adapt and stabilize the energy coming from the fuel cell, forming a useful system that serves as a base to supply power to the most diverse types of DC loads. In addition, we present a review of the direct-mode modulation strategies for the control of the output current in the static converter, updating data, and based on the voltage at the terminals of an inductor; how-ever, others strategies are naturally cited because there are combinations between the different modulating strategies and controllers commented on in the course of this work.

Page generated in 0.0784 seconds