Spelling suggestions: "subject:"conversores"" "subject:"inversores""
181 |
Estudo da modelagem dinâmica de pequenos sinais do conversor ZETA no MCD alimentado a partir de painéis fotovoltaicos para conexão à rede elétricaViero, Renan Caron January 2011 (has links)
Made available in DSpace on 2013-08-07T18:52:57Z (GMT). No. of bitstreams: 1
000434645-Texto+Completo-0.pdf: 2873661 bytes, checksum: 6694c7a444c8a14c7c6a3a5f6dbc2b1f (MD5)
Previous issue date: 2011 / This work presents the study and development of the small-signal dynamic modeling of the ZETA converter operating in discontinuous conduction mode, powered from photovoltaic solar panels in order to connect them to the power grid. Initially, it is presented a study of the main characteristics of solar cells. A deep analysis of the ZETA converter working in steady state is performed, considering that the Zeta converter synthesizes a rectified sine wave current with the same frequency as the power grid. This feature makes this converter a key part in implementing the module integrated inverter for photovoltaic systems. The converter is analyzed in the switching frequency and in the power grid frequency. A detailed examination of the dynamic behavior of the Zeta converter is achieved by the state-space averaging modeling approach, resulting in a linear analytical model described in state variables. In all tests it was assumed that the commercial power grid presents a resistive load behavior (variable value). Finally, the analytical dynamic model obtained is validated through computer simulations and by laboratory tests on a prototype specially designed for this purpose. / Este trabalho apresenta o estudo e o desenvolvimento da modelagem dinâmica de pequenos do conversor ZETA operando no modo de condução descontínuo, alimentado a partir de painéis solares fotovoltaicos, para conexão à rede elétrica. Inicialmente, é apresentado um estudo das principais características das células solares. Uma análise profunda sobre o conversor ZETA operando em regime permanente é realizada, considerando que o mesmo sintetiza uma onda senoidal retificada de baixa freqüência. O conversor é analisado tanto na freqüência de comutação como na freqüência da rede elétrica. Esta característica transforma este conversor em uma peça fundamental na implementação do inversor módulo integrado para sistemas fotovoltaicos. Um exame detalhado do comportamento dinâmico do conversor é realizado através da abordagem do modelo médio no espaço de estados, resultando em um modelo linear analítico descrito em variáveis de estado. Em todas as análises se assume a rede elétrica comercial como uma carga com comportamento resistivo (variável). Por fim, o modelo dinâmico analítico obtido é validado através de simulações computacionais e através de ensaios laboratoriais em um protótipo especialmente elaborado para este fim.
|
182 |
Inversor módulo integrado utilizando um conversor CC-CC Zeta com controle MPPT FeedForwardLopez, Henrique Fioravanti Miguel January 2009 (has links)
Made available in DSpace on 2013-08-07T18:53:44Z (GMT). No. of bitstreams: 1
000418751-Texto+Completo-0.pdf: 6725279 bytes, checksum: e5d1c8ffd25a23f7c4192f021029d702 (MD5)
Previous issue date: 2009 / This work presents the study and development of a processing power system that could be used in the connection of renewable energy sources to commercial power grid. The system consists of a ZETA converter associated with a bridge inverter operating at low frequency. The Zeta converter, operating in discontinuous conduction mode (DCM), plays the main role in this arrangement, producing a rectified sinusoidal current waveform synchronized with the electric grid. The function of the full-bridge inverter, connected in cascade with the Zeta converter, is to reverse every 180° the current generated by the Zeta converter. Initially it presents the analysis of the Zeta converter operating in DCM, as well as a design criterion. Following by the control strategy and the experimental results for the proposed system are presented and discussed. / Este trabalho apresenta um estudo do conversor CC-CC Zeta operando no modo de condução descontínuo, produzindo uma corrente senoidal retificada em sua saída, corrente esta que será entregue à rede elétrica comercial através de um inversor de ponte completa operando em baixa freqüência. O conversor Zeta, em conjunto com o inversor de ponte completa, forma o inversor módulo integrado. Um controle FeedForward é utilizado para se obter a máxima potência disponível nos painéis solares. Este controle é desenvolvido através de aproximações lineares das características elétricas dos painéis solares quando nestes incidem diferentes níveis de insolação e temperatura. É apresentado neste trabalho o modelo de espaços de estados médio para o conversor Zeta operando no modo de condução descontínuo, considerando a resistência interna da maioria dos seus componentes. Simulações e resultados experimentais são apresentados.
|
183 |
Método alternativo para sintonia de múltiplos controladores ressonantes aplicados em sistemas ininterruptos de energia (Nobreak)Carvalho, Fabio Medeiros de January 2013 (has links)
Este trabalho apresenta um método alternativo para sintonia de múltiplos controladores ressonantes aplicados aos sistemas ininterruptos de energia. A proposta do método é fornecer um conjunto de equações algébricas de simples aplicação que possibilite aos projetistas destes sistemas determinar os parâmetros dos controladores ressonantes com múltiplos modos. As equações apresentadas para determinação dos parâmetros do controlador foram obtidas diretamente com base nos parâmetros e nas características funcionais do inversor. Também nestas equações estão presentes constantes as quais garantem que todo o inversor cujo controlador for sintonizado pelo método atenda as especificações estabelecidas pela norma 60240-3. As constantes são determinadas através da formulação do problema por desigualdades matriciais lineares (LMI - Linear Matrix Inequalities) que levam em conta o equacionamento dinâmico do inversor e dos múltiplos controladores ressonantes. A solução do problema satisfaz simultaneamente a minimização do esforço de controle, onde foi empregada a formulação de custo garantido, juntamente com a localização dos polos de malha-fechada para toda a variação admissível de carga, formulada através do procedimento de D-Estabilidade. / This master thesis shows an alternative method for tuning multiple resonant controllers applied to uninterrupted power supply. The method is intended to provide a set of simple algebraic equations that enable designers of those systems to determine the parameters of the resonant controllers through multiple modes. The equations presented for determining the controller’s parameters were obtained directly based on the parameters and functional characteristics of the inverter. Additionally, constants that ensure that every inverter whose controller is attuned by the method meets the 60240-3 specifications norms can be found in these equations. The constants are determined based on the formulation of the problem through linear matrix inequalities (LMI) that take in consideration the dynamic of the inverter and of the multiple resonant controllers. The solution of the problem ensures both the needs for minimization of control efforts at guaranteed cost, along with the location of close-loop poles for every permissible load variation, formulated through the D-Stability procedure.
|
184 |
Determinação da eficiência de seguimento de máxima potência de inversorespara sistemas fotovoltaicos conectados à rede de distribuiçãoPrieb, César Wilhelm Massen January 2012 (has links)
A energia solar fotovoltaica é a forma de produção de eletricidade que mais cresce no mundo. A potência instalada mundial, até o ano de 2010, era de cerca de 40 GWP e a previsão é de que, somente em 2011, este cifra seja aumentada em mais 24 GWP. O inversor é o elemento central dos sistemas fotovoltaicos. Além de executar a conversão da energia elétrica em corrente contínua para corrente alternada, ele também é responsável pelo gerenciamento da energia entregue à rede e pelo seguimento do ponto de máxima potência. O seguimento do ponto de máxima potência (MPPT) é um processo de controle no qual o inversor procura manter o gerador fotovoltaico operando em uma região da sua curva característica na qual o produto corrente × tensão tenha o seu valor máximo, de forma a otimizar a extração de potência do gerador fotovoltaico. A eficiência de MPPT é um número que indica o grau de precisão, tanto em termos de rapidez como de magnitude, com que o seguidor do ponto de máxima potência atinge o seu objetivo. Assim podem ser definidas duas eficiências de MPPT: a eficiência estática, associada a situações em que a irradiância solar permanece constante durante o intervalo considerado, e a eficiência dinâmica de MPPT, que considera os momentos de variação na intensidade da irradiância, resultantes, por exemplo, da passagem de nuvens. As eficiências de MPPT (especialmente a dinâmica) são de difícil determinação, porém a tarefa fica muito facilitada com a utilização de um simulador de arranjos fotovoltaicos. A norma européia EN 50530:2010 Overall Efficiency of Photovoltaic Inverters propôs uma metodologia para a determinação da eficiência dinâmica de MPPT utilizando perfis variáveis de irradiância a serem programados no simulador de arranjos fotovoltaicos. O objetivo central da tese é fazer uma análise experimental da eficiência dinâmica do seguimento de máxima potência de inversores conectados à rede através da comparação dos resultados de eficiência obtidos seguindo a metodologia definida na norma citada com resultados obtidos a partir de medições em tempo real ao longo de um dia, verificando a adequação da norma às situações de campo. Para a obtenção dos dados de entrada do simulador foram medidas, por diversos dias, a irradiância e temperatura de uma célula de referência. Os inversores foram conectados à saída do simulador de arranjos fotovoltaicos e foram reproduzidas as condições de irradiância e temperatura de três dias selecionados em função do grau de nebulosidade, com comportamento dinâmico semelhante aos perfis de irradiância da norma. Os resultados foram, na maioria dos casos, discordantes. Uma análise dos resultados parciais de eficiência dinâmica indicou como causa desta discrepância a dependência que a eficiência dinâmica de MPPT tem com a taxa de variação da irradiância. Conclui-se que, embora as seqüências de irradiância propostas pela norma constituam uma eficiente ferramenta para o diagnóstico de eventuais deficiências no comportamento do seguidor de máxima potência de inversores, a média dos valores de eficiência de MPPT calculados a partir delas não pode, em princípio, ser considerada como representativa de valores diários. / Photovoltaic solar energy is the fastest growing electricity source in the world. The worldwide capacity until 2010 was about 40 GWP and, by the end of 2011, this figure will be increased by another 24 GWP. The inverter is the pivotal element of PV systems. In addition to performing the conversion of electrical energy from direct current to alternating current, the inverter is also responsible for the management of the energy delivered to the grid and for performing the maximum power point tracking. The maximum power point tracking (MPPT) is a control process by which the inverter tries to keep the PV generator operating in a region of its characteristic curve where the product current × voltage reaches its maximum value. The MPPT efficiency is a figure that indicates the degree of precision, both in terms of speed and magnitude, that the MPPT reaches its goal. Thus, two MPPT efficiencies can be defined: the static efficiency, associated to situations in which the solar irradiance does not vary during the considered interval, and also the dynamic MPPT efficiency, which considers the variation of the irradiance intensity as a result, for example, of the passage of clouds. MPPT efficiencies (especially the dynamic) are hard to determine, but the task becomes much easier with the use of a photovoltaic array simulator. The European standard EN 50530:2010 Overall Efficiency of Photovoltaic Inverters proposes a methodology for determining the dynamic efficiency of MPPT using variable irradiance profiles to be programmed into the photovoltaic array simulator. The main objective of this thesis is to make an experimental analysis of the dynamic MPPT efficiency of grid connected inverters by comparing the efficiency results obtained by following the methodology defined in the referred standard with results obtained from real time measurements in the course of a day, checking the adequacy of the standard when applied to field situations. In order to obtain the input data for the simulator, the irradiance and temperature of a reference cell were measured for several days. The inverters were connected to the output of the array simulator, which reproduced the conditions of irradiance and temperature for three days selected according to the degree of cloudiness, having a dynamic behavior similar to the standard irradiance profiles. The results, in most cases, disagree. An analysis of partial results of dynamic efficiency indicated the dependence of the dynamic MPPT efficiency to the rate of irradiance change as the cause of this discrepancy. As a conclusion, it can be stated that, although the sequences of irradiance proposed by the standard are an efficient tool for the diagnosis of deficiencies in the behavior of the MPP tracker, the average efficiency of MPPT calculated from the sequences cannot, in principle, to be considered as representative of the daily values of dynamic MPPT efficiency.
|
185 |
Modelagem e simulação da proteção de alimentadores de distribuição utilizando softwares tipo EMTPConceição, Everaldo Nonato da 10 August 2012 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2012. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2013-01-03T11:18:02Z
No. of bitstreams: 1
2012_EveraldoNonatoConceicao.pdf: 6088305 bytes, checksum: 737c0f603537010aff08a12834b622db (MD5) / Approved for entry into archive by Luanna Maia(luanna@bce.unb.br) on 2013-03-01T13:42:05Z (GMT) No. of bitstreams: 1
2012_EveraldoNonatoConceicao.pdf: 6088305 bytes, checksum: 737c0f603537010aff08a12834b622db (MD5) / Made available in DSpace on 2013-03-01T13:42:05Z (GMT). No. of bitstreams: 1
2012_EveraldoNonatoConceicao.pdf: 6088305 bytes, checksum: 737c0f603537010aff08a12834b622db (MD5) / Neste trabalho é desenvolvido e implementado modelos de dispositivos usados na proteção
de sobrecorrente de redes de distribuição como: religadores, seccionalizadores, fusíveis, relés digitais e transformadores de corrente. Nesse sentido realiza-se uma revisão teórica
abordando a proteção de sobrecorrente da rede de distribuição, com foco nos ajustes, coordenação, e teoria de relé digital. Apresenta-se um memorial de cálculo de dimensionamento dos elementos de proteção de acordo com os parâmetros elétricos e físicos da rede de distribuição. A implementação computacional foi elaborada utilizando
como ferramenta de trabalho o ATP (Alternative Transients Program) em conjunto com a
MODELS para simular, modelar, visualizar o comportamento da proteção por sobrecorrente da rede de distribuição. Realizam-se inúmeros testes de curtos-circuitos (monofásicos, bifásicos, trifásicos) em vários pontos da rede de distribuição para validar os modelos desenvolvidos e verificar o desempenho da proteção por sobrecorrente. São
avaliados os curtos-circuitos, os ajustes e a coordenação que podem afetar na atuação da proteção do sistema. Os resultados mostraram que se pode fazer, de modo satisfatório, consistente, a proteção de uma rede de distribuição com o uso da modelagem e simulação utilizando software ATP/MODELS. O estudo desenvolvido neste trabalho pode contribuir na solução de problemas de ajustes, coordenação e análise do comportamento da rede de
distribuição na presença de falta provocada por uma sobrecorrente. ______________________________________________________________________________ ABSTRACT / This work develops and implements models for overcurrent protection devices such as recloser, sectionalizers, digital relays, fuses and current transformers. A literature review on overcurrent protection of electric distribution networks is carried out, focusing on
settings, coordination and digital relay theory. Based on electric and physical parameters of such networks, we present a memorial sizing calculation of protection devices. As for tools, we used the ATP (Alternative Transients Program) and its MODELS interface in order to model, simulate and visualize the behavior of the overcurrent protection mechanism applied to distribution networks. Aiming to validate the developed models and
evaluate the performance of the overcurrent protection system, we analyze a wide variety of faults in a distribution network. Specifically, we evaluated short circuit conditions, proper settings and coordination that can affect the operation of system protection. The
obtained results show that it is possible to consistently evaluate the performance of distribution network protection by using the ATP/MODELS application. In summary, the
contributions in this work will be useful in adjusting, coordinating and evaluating the behavior of the electric distribution network under fault due to overcurrent.
|
186 |
Modelagem e simulação da proteção diferencial de transformadores de potência no ATPTavares, Karla Antunes 06 December 2013 (has links)
Dissertação (mestrado)—Universidade de Brasília, Departamento de Engenharia Elétrica,
Faculdade de Tecnologia, 2013. / Submitted by Alaíde Gonçalves dos Santos (alaide@unb.br) on 2014-03-14T11:37:03Z
No. of bitstreams: 1
2013_KarlaAntunesTavares.pdf: 3728993 bytes, checksum: 2b32c9449cb028c961026b0ba9b0335a (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2014-03-19T13:28:18Z (GMT) No. of bitstreams: 1
2013_KarlaAntunesTavares.pdf: 3728993 bytes, checksum: 2b32c9449cb028c961026b0ba9b0335a (MD5) / Made available in DSpace on 2014-03-19T13:28:18Z (GMT). No. of bitstreams: 1
2013_KarlaAntunesTavares.pdf: 3728993 bytes, checksum: 2b32c9449cb028c961026b0ba9b0335a (MD5) / Este trabalho tem por objetivo apresentar a modelagem e simulação de um relé numérico microprocessado para proteção de transformadores de potência. Foram implementadas as funções de proteção diferencial percentual de fase (87T), de sequência negativa (87Q) e de falta à terra restrita (REF). Para tanto, utiliza-se o software ATP, através de sua interface ATPDraw, sendo o relé implementado no ambiente MODELS. A validação do modelo foi feita para um sistema elétrico de potência simplificado, cujos parâmetros foram obtidos a partir de dados dos componentes de um sistema real. Os resultados mostram as vantagens da utilização desse tipo de modelagem, uma vez que ela permite a realização da chamada simulação em malha fechada, por meio da qual é possível avaliar o comportamento do sistema de potência frente à operação da sua proteção, bem como o da proteção frente as mais diversas situações de operação às quais um sistema de potência pode ser submetido. Além disso, também são observadas as vantagens de se utilizar de forma combinada as três funções de proteção implementadas. _______________________________________________________________________________________ ABSTRACT / This work aims to present the modeling and simulation of a numerical relay for protection of power transformers. It was implemented the phase percentage differential function (87T), negative sequence (87Q) and restricted earth fault (REF). In order to do so, the software ATP was used, through its interface ATPDraw, and the relay was implemented using the MODELS language. The model validation was carried out for a simplified electric power system, whose parameters were obtained from data of the components of a real system. The results reveal the advantages of using this type of modeling, since it provides a closed loop simulation, thereby one can evaluate the behavior of the power system against the protection operation, as well as the protection performance for the different power systems operational conditions. Moreover, one can see the advantages of using the three protection functions implemented together.
|
187 |
Determinação da eficiência de seguimento de máxima potência de inversorespara sistemas fotovoltaicos conectados à rede de distribuiçãoPrieb, César Wilhelm Massen January 2012 (has links)
A energia solar fotovoltaica é a forma de produção de eletricidade que mais cresce no mundo. A potência instalada mundial, até o ano de 2010, era de cerca de 40 GWP e a previsão é de que, somente em 2011, este cifra seja aumentada em mais 24 GWP. O inversor é o elemento central dos sistemas fotovoltaicos. Além de executar a conversão da energia elétrica em corrente contínua para corrente alternada, ele também é responsável pelo gerenciamento da energia entregue à rede e pelo seguimento do ponto de máxima potência. O seguimento do ponto de máxima potência (MPPT) é um processo de controle no qual o inversor procura manter o gerador fotovoltaico operando em uma região da sua curva característica na qual o produto corrente × tensão tenha o seu valor máximo, de forma a otimizar a extração de potência do gerador fotovoltaico. A eficiência de MPPT é um número que indica o grau de precisão, tanto em termos de rapidez como de magnitude, com que o seguidor do ponto de máxima potência atinge o seu objetivo. Assim podem ser definidas duas eficiências de MPPT: a eficiência estática, associada a situações em que a irradiância solar permanece constante durante o intervalo considerado, e a eficiência dinâmica de MPPT, que considera os momentos de variação na intensidade da irradiância, resultantes, por exemplo, da passagem de nuvens. As eficiências de MPPT (especialmente a dinâmica) são de difícil determinação, porém a tarefa fica muito facilitada com a utilização de um simulador de arranjos fotovoltaicos. A norma européia EN 50530:2010 Overall Efficiency of Photovoltaic Inverters propôs uma metodologia para a determinação da eficiência dinâmica de MPPT utilizando perfis variáveis de irradiância a serem programados no simulador de arranjos fotovoltaicos. O objetivo central da tese é fazer uma análise experimental da eficiência dinâmica do seguimento de máxima potência de inversores conectados à rede através da comparação dos resultados de eficiência obtidos seguindo a metodologia definida na norma citada com resultados obtidos a partir de medições em tempo real ao longo de um dia, verificando a adequação da norma às situações de campo. Para a obtenção dos dados de entrada do simulador foram medidas, por diversos dias, a irradiância e temperatura de uma célula de referência. Os inversores foram conectados à saída do simulador de arranjos fotovoltaicos e foram reproduzidas as condições de irradiância e temperatura de três dias selecionados em função do grau de nebulosidade, com comportamento dinâmico semelhante aos perfis de irradiância da norma. Os resultados foram, na maioria dos casos, discordantes. Uma análise dos resultados parciais de eficiência dinâmica indicou como causa desta discrepância a dependência que a eficiência dinâmica de MPPT tem com a taxa de variação da irradiância. Conclui-se que, embora as seqüências de irradiância propostas pela norma constituam uma eficiente ferramenta para o diagnóstico de eventuais deficiências no comportamento do seguidor de máxima potência de inversores, a média dos valores de eficiência de MPPT calculados a partir delas não pode, em princípio, ser considerada como representativa de valores diários. / Photovoltaic solar energy is the fastest growing electricity source in the world. The worldwide capacity until 2010 was about 40 GWP and, by the end of 2011, this figure will be increased by another 24 GWP. The inverter is the pivotal element of PV systems. In addition to performing the conversion of electrical energy from direct current to alternating current, the inverter is also responsible for the management of the energy delivered to the grid and for performing the maximum power point tracking. The maximum power point tracking (MPPT) is a control process by which the inverter tries to keep the PV generator operating in a region of its characteristic curve where the product current × voltage reaches its maximum value. The MPPT efficiency is a figure that indicates the degree of precision, both in terms of speed and magnitude, that the MPPT reaches its goal. Thus, two MPPT efficiencies can be defined: the static efficiency, associated to situations in which the solar irradiance does not vary during the considered interval, and also the dynamic MPPT efficiency, which considers the variation of the irradiance intensity as a result, for example, of the passage of clouds. MPPT efficiencies (especially the dynamic) are hard to determine, but the task becomes much easier with the use of a photovoltaic array simulator. The European standard EN 50530:2010 Overall Efficiency of Photovoltaic Inverters proposes a methodology for determining the dynamic efficiency of MPPT using variable irradiance profiles to be programmed into the photovoltaic array simulator. The main objective of this thesis is to make an experimental analysis of the dynamic MPPT efficiency of grid connected inverters by comparing the efficiency results obtained by following the methodology defined in the referred standard with results obtained from real time measurements in the course of a day, checking the adequacy of the standard when applied to field situations. In order to obtain the input data for the simulator, the irradiance and temperature of a reference cell were measured for several days. The inverters were connected to the output of the array simulator, which reproduced the conditions of irradiance and temperature for three days selected according to the degree of cloudiness, having a dynamic behavior similar to the standard irradiance profiles. The results, in most cases, disagree. An analysis of partial results of dynamic efficiency indicated the dependence of the dynamic MPPT efficiency to the rate of irradiance change as the cause of this discrepancy. As a conclusion, it can be stated that, although the sequences of irradiance proposed by the standard are an efficient tool for the diagnosis of deficiencies in the behavior of the MPP tracker, the average efficiency of MPPT calculated from the sequences cannot, in principle, to be considered as representative of the daily values of dynamic MPPT efficiency.
|
188 |
Método alternativo para sintonia de múltiplos controladores ressonantes aplicados em sistemas ininterruptos de energia (Nobreak)Carvalho, Fabio Medeiros de January 2013 (has links)
Este trabalho apresenta um método alternativo para sintonia de múltiplos controladores ressonantes aplicados aos sistemas ininterruptos de energia. A proposta do método é fornecer um conjunto de equações algébricas de simples aplicação que possibilite aos projetistas destes sistemas determinar os parâmetros dos controladores ressonantes com múltiplos modos. As equações apresentadas para determinação dos parâmetros do controlador foram obtidas diretamente com base nos parâmetros e nas características funcionais do inversor. Também nestas equações estão presentes constantes as quais garantem que todo o inversor cujo controlador for sintonizado pelo método atenda as especificações estabelecidas pela norma 60240-3. As constantes são determinadas através da formulação do problema por desigualdades matriciais lineares (LMI - Linear Matrix Inequalities) que levam em conta o equacionamento dinâmico do inversor e dos múltiplos controladores ressonantes. A solução do problema satisfaz simultaneamente a minimização do esforço de controle, onde foi empregada a formulação de custo garantido, juntamente com a localização dos polos de malha-fechada para toda a variação admissível de carga, formulada através do procedimento de D-Estabilidade. / This master thesis shows an alternative method for tuning multiple resonant controllers applied to uninterrupted power supply. The method is intended to provide a set of simple algebraic equations that enable designers of those systems to determine the parameters of the resonant controllers through multiple modes. The equations presented for determining the controller’s parameters were obtained directly based on the parameters and functional characteristics of the inverter. Additionally, constants that ensure that every inverter whose controller is attuned by the method meets the 60240-3 specifications norms can be found in these equations. The constants are determined based on the formulation of the problem through linear matrix inequalities (LMI) that take in consideration the dynamic of the inverter and of the multiple resonant controllers. The solution of the problem ensures both the needs for minimization of control efforts at guaranteed cost, along with the location of close-loop poles for every permissible load variation, formulated through the D-Stability procedure.
|
189 |
Controle por inclinação para Paralelismo de Inversores em MicrorredesSIQUEIRA, Emerson Sarmanho 28 August 2013 (has links)
Submitted by Amanda Freitas (amanda.freitas@ufpe.br) on 2015-04-17T13:21:45Z
No. of bitstreams: 2
DISSERTAÇÃO Emerson Sarmanho Siqueira.pdf: 6786686 bytes, checksum: 0b0c69428f0626b5d755c767c7b2de51 (MD5)
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-04-17T13:21:45Z (GMT). No. of bitstreams: 2
DISSERTAÇÃO Emerson Sarmanho Siqueira.pdf: 6786686 bytes, checksum: 0b0c69428f0626b5d755c767c7b2de51 (MD5)
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Previous issue date: 2013-08-28
|
190 |
Redução da potência dinâmica de circuitos integrados através da utilização de múltiplas tensões de alimentaçãoda Silva Clemente, Gabriela 31 January 2010 (has links)
Made available in DSpace on 2014-06-12T15:57:04Z (GMT). No. of bitstreams: 2
arquivo3137_1.pdf: 1263423 bytes, checksum: 6193c47086f4fa0833586f510e15f675 (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2010 / Atualmente, a redução do consumo de potência é um dos principais desafios no
domínio de projeto de circuitos integrados digitais. A evolução da tecnologia de fabricação
dos circuitos integrados, chegando a dimensões nanométricas nos dias atuais, torna os
problemas relacionados ao consumo de potência ainda mais críticos devido à alta densidade
de transistores no chip. Apesar do crescente aumento do consumo de potência estática, a
potência dinâmica, dissipada quando o nível lógico do transistor está em transição, ainda
representa uma fração significante da potência consumida pelos dispositivos eletrônicos. A
proposta deste trabalho é prover uma revisão das abordagens desenvolvidas com a finalidade
de reduzir a potência dinâmica de circuitos integrados no nível de porta lógica utilizando a
técnica Multi-VDD e, além disso, propor melhorias em uma das metodologias estudadas. A
técnica Multi-VDD detecta as portas lógicas do circuito que podem ter suas tensões de
alimentação reduzidas sem que violações de tempo sejam inseridas no circuito. Para manter a
integridade dos sinais do circuito, eventualmente, células especiais chamadas conversores de
nível precisam ser inseridas no circuito. O algoritmo proposto foi validado através de sua
aplicação em circuitos do benchmark ISCAS85. Os resultados obtidos foram bastante
satisfatórios atingindo em média uma redução de potência de 18,31% em relação ao consumo
de potência dinâmica inicial quando se utilizou uma restrição de tempo menos conservadora,
e de 4,27% com uma restrição de tempo conservadora
|
Page generated in 0.0485 seconds