• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 31
  • 1
  • Tagged with
  • 32
  • 32
  • 18
  • 17
  • 9
  • 9
  • 9
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Avaliação da coleta de sangue em papel de filtro para diagnóstico molecular da dengue / Evaluation of blood collected in fta cards for the detection of dengue virus RNA

Célia Luiza de Lima Rodrigues 21 October 2010 (has links)
O diagnóstico rotineiro da dengue é realizado com amostra de sangue dos casos suspeitos. A coleta tradicional de sangue (por punção venosa) é um procedimento que dificulta a realização de exames e pesquisas por ser um procedimento invasivo que nem sempre é prático para crianças e bebês, requer pessoal especializado e necessita de um local para armazenamento da amostra sob refrigeração ou congelamento. O propósito deste estudo foi coletar amostras por punção digital com uma nova tecnologia (FTA Card) e compará-la com amostras coletadas por punção venosa, avaliando-as através de uma técnica molecular de PCR em tempo real. Sendo o PCR em Tempo Real a técnica molecular atualmente disponível de maior rapidez, sensibilidade e especificidade, padronizamos uma metodologia de passo único de PCR em Tempo Real com SYBR green baseando-se na região 3 não codificante do vírus e utilizando primers degenerados, capazes de detectar os quatro sorotipos de uma só vez. A avaliação das técnicas de coleta e amplificação foram feitas com amostras suspeitas de dengue, obtidas em Goiânia durante surto ocorrido no ano de 2008. O limite de detecção da reação padronizada no presente estudo foi de aproximadamente 100 cópias/ml e uma especificidade de 100%. Para tipagem das amostras positivas a técnica empregada foi o PCR multipex. Dentre as 89 amostras coletadas 60 (67%) foram positivas para àquelas coletadas por punção venosa e 14 (16%) para àquelas coletadas por punção digital. Dentre as 89 amostras para o PCR em Tempo Real, apenas 29 (32%), foram tipadas pelo método de PCR multiplex, sendo 3 casos do vírus da dengue 1 (10%), 16 casos do vírus da dengue 2 (55%), e 10 casos do vírus da dengue 3 (35%). Descritores: Dengue/diagnóstico, coleta de amostras sanguíneas, reação em cadeia da polimerase, corantes fluorescentes / The collection by venipuncture is a procedure that is difficult to carry out in diagnosis and research because it is an invasive procedure that is not always practical for children and babies , requires specialized staff, needs a place to store the sample under refrigeration or forzen, This study aimed to collect samples by fingerstick puncture with a new technology named FTA card and compare it with samples collected by venipuncture, using a realtime PCR to evaluate if FTA card collection would have a similar performance to standard blood sampling. Towards that, we obtained viral load values in order to estimate the differences not only qualitatively (e.g. pos or neg) but also in numbers.. We used an one-step SYBR Green I Real-Time PCR based on the region 3 \'noncoding virus using degenerate primers which was able to detected all four serotypes of dengue virus. Among the 89 samples collected 60 (67%) were positive for those collected by venipuncture and 14 (16%) to those collected by fingerstick, Only 29 (32%) were possible to be typed by PCR multiplex. Three cases were dengue virus 1 (10%), 16 cases were dengue virus 2 (55%) and 10 cases were dengue virus 3 (35%). The limit of detection obtained was approximately 100 copies / ml and aspecificity of 100% was observed. Keywords: Dengue / diagnosis, collection of blood samples, polymerase chain reaction, fluorescent dyes
32

Fluorescência induzida por plasmons superficiais em corantes

NOGUEIRA, Maxwell Aragão Marques January 2007 (has links)
Made available in DSpace on 2014-06-12T18:06:16Z (GMT). No. of bitstreams: 2 arquivo7713_1.pdf: 722814 bytes, checksum: 2e4a6c4e83b9b21d12bc70bea26edd8d (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2007 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Plasmons, oscilações coletivas de elétrons de condução, podem ter grande influência sobre as propriedades ópticas de micro e nanoestruturas metálicas, e são de grande interesse no desenvolvimento de dispositivos fotônicos. Neste trabalho, produzimos filmes finos metálicos pelo método de evaporação à baixa pressão e, em seguida, fizemos a sua caracterização por medidas de refletividade óptica. A partir daí, estudamos o comportamento da emissão espontânea (fluorescência) induzida por plasmons superficiais em interfaces metal-dielétrico. O sistema estudado era constituído por um corante dissolvido em uma matriz polimérica pura ou contendo nanopartículas de prata ou de rutila. A excitação de plasmons foi obtida pelo uso da técnica de reflexão total atenuada (Configuração de Kretschmann-Raether), e foram utilizadas medidas de luminescência na detecção de sinal de fluorescência induzida por plasmons superficiais. A intensidade da fluorescência e sua largura de linha foram analisadas em função da intensidade de luz incidente na amostra. Foi observado que, para altas intensidades, a forma de linha da luminescência era modificada, indicando a ocorrência de emissão estimulada, mas com baixa eficiência devido à baixa potência do laser utilizado

Page generated in 0.1566 seconds