• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 31
  • 1
  • Tagged with
  • 32
  • 32
  • 18
  • 17
  • 9
  • 9
  • 9
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Testes fluorimétricos na sorologia da toxoplasmose humana: detecção simultânea de anticorpos de IgG e IgM específicos / Fluorimetric immunoassay in human toxoplasmosis: simultaneous detection of specific IgG and IgM antibodies

Rodrigues, Jaqueline Polizeli 14 February 2014 (has links)
A toxoplasmose, protozoose disseminada de baixa morbidade, apresenta número significativo de doença ocular, congênita ou do sistema nervoso central. O diagnóstico é sorológico por diferentes testes, mas limiares baixos e variação individual levam a frequentes problemas. Novos imunoensaios fluorescentes de fase sólida (FLISA) usam a quantificação direta de anticorpos. Aqui, desenvolvemos um FLISA multiplex (FLISAm) para a detecção simultânea de anticorpos IgG e IgM contra Toxoplasma gondii. Após padronização, a eficiência do FLISAm com conjugados comerciais foi feita inicialmente de forma isolada para cada imunoglobulina em 140 amostras de soro de universitários previamente analisadas pelo ELISA IgG/IgM. FLISA IgG mostrou boa concordância (Kappa=0,7088), com sensibilidade de 83,3% e especificidade de 94,2%, enquanto FLISA IgM apresentou boa concordância (K=0,6026), menor sensibilidade de 55,5% e igual especificidade de 98,4%. Foram produzidos novos conjugados fluorescentes de maior especificidade e seu desempenho no FLISAm foi validado em 24 amostras e sua eficiência foi avaliada em 120 amostras conhecidas de soro de gestantes. FLISAm mostrou excelente concordância, tanto para a detecção de anticorpos IgG (K=0.8837, sensibilidade=100,0%, especificidade=87,5%), quanto para a detecção de anticorpos IgM (K=0,9187, sensibilidade=100%, especificidade=99,1%) com excelente reprodutibilidade. O teste desenvolvido é rápido, econômico, de fácil execução, alto rendimento e que pode ser utilizado como método de triagem de soroconversão em mulheres grávidas, útil em aplicações de grande número de amostras como o cuidado pré-natal. / Toxoplasmosis, a disseminated low morbidity protozoan disease, presented significant numbers of affected people, mainly ocular disease, fetal infections or encephalitis in immune deficient patients. Serology is the main diagnosis with commercial antibody assays, but individual variation or low thresholds cause many inconsistencies. New solid phase immunofluorescence assays (FLISA) allows direct antibody quantification in microplates. Here, we developed a multiplex FLISA (FLISAm) for simultaneous detection of IgG and IgM anti-Toxoplasma gondii antibodies. After standardization, the efficiency of this method was initially analyzed in isolated FLISA for each immunoglobulin with commercial conjugates in 140 serum samples of the students previously screened by IgG/IgM ELISA. IgG FLISA showed good concordance (Kappa=0.7088), 83,3% sensitivity and 94,2% specificity, while IgM FLISA also showed good concordance (Kappa=0,6026), lower 55,5% sensitivity and similar 98,4% specificity. New higher efficiency conjugated were prepared and tested in 120 serum samples of the pregnant woman in a same well conjunct IgG/IgM FLISAm. We also validate the FLISAm in 24 serum samples. Compared to isolated ELISA IgG/IgM, FLISAm demonstrated excellent concordance for IgG (Kappa=0.8837; sensitivity=100%; specificity=87,5%,) and IgM (Kappa=0,9187; sensitivity=100%; specificity=99,1%), with excellent reproducibility. The standardized FLISAm is quick, inexpensive, easily performed and high throughput and the assay can be used for screening serum conversion in pregnant women, useful in large numbers applications as antenatal care.
12

Análise do efeito de adição do marcador Rodamina B em propriedades mecânicas de sistemas adesivos não simplificados / Analysis of the effect of addition of Rhodamine B marker on mechanical properties of non-simplified adhesives

Machado, Camila Moreira 12 December 2014 (has links)
Este estudo in vitro avaliou o efeito da adição de rodamina B dissolvida em etanol nas concentrações de 0,02mg/mL e 0,10mg/mL, nas propriedades mecânicas dos sistemas adesivos não simplificados considerados padrão-ouro. 96 coroas de terceiros molares humanos hígidos foram seccionadas transversalmente no terço oclusal para remoção do esmalte e exposição da dentina. Os espécimes foram divididos de acordo com os sistemas adesivos Adper Scotchbond Multi-Purpose (MP) - convencional de três passos ou Clearfil SE Bond (SE) - autocondicionante de dois passos: MP-C e SE-C (MP e SE controles); MP-C1 e SE-C1 (MP e SE com rodamina B 0,02mg/mL); MP-C2 e SE-C2: (MP e SE com rodamina B 0,10mg/mL). Para o teste de RU, os espécimes (n=10) foram submetidos ao desgaste com lixas de granulação 320 e 600. A dentina foi tratada de acordo com as instruções de cada fabricante dos sistemas adesivos e restaurada com resina composta FiltekTM Z250. Após o armazenamento em saliva artificial (7dias/37oC), os espécimes foram seccionados para obtenção de palitos com 0,64 mm2 de área média e submetidos ao teste de microtração em máquina de teste universal a 0,5 mm/min, que foram analisados após 7 dias e 6 meses. O modo de fratura dos espécimes foi analisado com estereomicroscópio digital (x200) e classificado em: adesiva, coesiva em dentina, coesiva em resina e mista. Para o teste de MS, as coroas seccionadas (n=6) foram planificadas com lixa de granulação 600. A dentina foi tratada de acordo com as instruções de cada fabricante dos sistemas adesivos e os espécimes foram mantidos secos em estufa a 37oC durante 48 horas. O teste de MS foi realizado utilizando ponta Knoop (Microdurômetro Shimadzu HMV-2), a 10x e carga estática de 25gF por 10 segundos. Os resultados obtidos foram analisados por análise de variância (ANOVA-2 critérios) e teste de Bonferroni para comparações múltiplas (p<0,05). A análise de acordo com o tempo foi realizada com o teste de t-student. Os valores médios de RU e desvio padrão (MPa±dp; 7 dias / 6 meses) foram: MP-C (41,95±2,38 / 22,76±3,66); MP-C1 (28,02±5,12 / 17,93±5,70); MP-C2 (26,28±5,55 / 14,30±5,68); SE-C (46,07±1,43 / 19,07±6,75); SE-C1 (37,49±13,31 / 18,54±6,71); SE-C2 (34,16±7,71 / 17,89±4,87). No tempo de 7 dias, os fatores sistema adesivo e concentração de rodamina B foram significantes. Após 6 meses, apenas o fator concentração de rodamina B foi significante. A falha de fratura predominante em todos os grupos foi adesiva. Os valores de MS (KHN) e desvio padrão foram: MP-C (8,97±3,85); MP-C1 (7,33±0,99); MP-C2 (7,17±2,45); SE-C (4,71±4,42); SE-C1 (4,42±0,56); SE-C2 (3,27±0,30). Na comparação entre os sistemas adesivos, eles diferiram entre si na condição controle e de 0,10mg/mL. Para cada adesivo, não houve diferença entre as distintas condições de acordo com a adição de rodamina B. Em função dos resultados apresentados, a adição de rodamina B nos sistemas adesivos não simplificados MP e SE, nas concentrações de 0,02mg/mL e 0,10mg/mL, deve ser incorporada com cautela para que não influencie nas propriedades mecânicas do material. / This in vitro study evaluated the effect of addition of rhodamine B dissolved in ethanol in concentrations of 0.02mg/mL and 0.10mg/mL, the mechanical properties of non-simplified adhesive systems. 96 crowns of human third molars were transversely sectioned on the oclusal third to remove the enamel and exposure the dentin. The specimens were divided according to the adhesive systems Adper Scotchbond Multi-Purpose (MP) 3-step-etch-andrinse or Clearfil SE Bond (SE) 2-step-self-ecthing: MP-C and SE-C (MP and SE controls); MP-C1 and SE-C1 (MP and SE with 0.02mg/mL rhodamine B); MP-C2 and SE-C2: (MP and SE with 0.10mg/mL rhodamine B). For the &#x3BC;TBS test, the specimens (n=10) were ground with 320- to 600-grit silicon carbide paper. The dentin was treated according to the instructions of each manufacturer and restored with composite resin FiltekTM Z250. The specimens were stored in artificial saliva (7 days/37oC), and then sectioned to obtain sticks with an average of 0.64 mm2 area and submitted to &#x3BC;TBS test at a universal testing machine at 0.5 mm/min, which were analyzed immediately after 7 days and 6 months. The mode of fracture of the specimens was analyzed with digital stereomicroscope (x200) and classified as: adhesive, cohesive in dentine, cohesive in resin and mixed. For the SM test, the sectioned crowns (n=6) were flattened with 600-grit silicon carbide paper. The dentin was treated according to the manufacturers instructions for each adhesive system and the specimens were stored in dry condition at 37oC during 48 hours. The SM test was performed with Knoop indenter (Shimadzu HMV-2 hardness tester), at 10x and 25gF of load for 10 seconds. The results were analyzed by two-way analysis of variance tests and the Bonferroni test for multiple comparisons (p<0.05). The analysis regarding time was checked with t-student test. The mean &#x3BC;TBS and standard deviation (MPa±dp; 7 days / 6 months) were: MP-C (41.95±2.38 / 22.76±3.66); MP-C1 (28.02±5.12 / 17.93±5.70); MP-C2 (26.28±5.55 / 14.30±5.68); SE-C (46.07±1.43 / 19.07±6.75); SE-C1 (37.49±13.31 / 18.54±6.71); SE-C2 (34.16±7.71 / 17.89±4.87). In the immediate time, the adhesive system and rhodamine B concentration factors were significant. After 6 months, only the rhodamine B concentration was a significant factor. The predominant failure in all groups was adhesive. The values of SM and standard deviation were: MP-C (8.97±3.85); MP-C1 (7.33±0.99); MP-C2 (7.17±2.45); SE-C (4.71±4.42); SE-C1 (4.42±0.56); SE-C2 (3.27±0.30). In the comparison between the adhesive systems, they were significantly different for the conditions control and 0.10mg/mL. For each adhesive systems, there was no difference between the different conditions according to the addition of rhodamine B. Regarding the shown results, addition of rodhamine B in non-simplified adhesives MP and SE, in the concentrations of 0.02mg/mL e 0.10mg/mL must be carefully added to avoid implications to the mechanical properties of the materials.
13

Obtenção de materiais orgânicos conjugados com corantes fluorescentes para a marcação de nanocápsulas poliméricas com potencial aplicação em diagnóstico e terapêutica

Prado, Willian Andrade January 2014 (has links)
Sistemas nanocarreadores de moléculas orgânicas têm emergido como promissores sistemas para aplicação na terapêutica e/ou diagnóstico. No presente trabalho foram desenvolvidas nanocápsulas poliméricas contendo, em seus diferentes domínios, sondas fluorescentes capazes de fornecer imagem quando analisadas em microscópio de fluorescência confocal, mostrando as potencialidades do sistema como agente para imagem ótica. Uma importante característica de moléculas propostas como marcadores fluorescentes, é que não haja sobreposição dos espectros de absorção e emissão de fluorescência. Para tanto, foi utilizado um corante sintético do grupo dos benzoxazólicos (HBO-C8) para marcação do núcleo lipofílico, e os polímeros PCL e quitosana foram ligados covalentemente aos corantes rodamina B e alaranjado de acridina, respectivamente. As formulações desenvolvidas e caracterizadas com dois ou três marcadores apresentaram caráter nanotecnológico e as fotomicrografias de transmissão revelaram que as nanopartículas contendo HBO-C8 e PCL-Rho (sem quitosana), preservou a morfologia da nanopartícula. Adicionalmente, o HBO-C8 foi quantificado na formulação contendo HBO-C8 e PCL-Rho, onde verificou-se que 98% do corante está internalizado na nanopartícula, alcançando assim, o objetivo proposto de usá-lo como sonda para marcação do núcleo lipofílico. Por meio da microscopia de fluorescência confocal, foram obtidas imagens dos marcadores fluorescentes colocalizados, para as formulações contendo dois ou três domínios fluorescentes, demonstrando que essas nanocápsulas podem ser propostas como uma plataforma promissora para serem empregadas como sondas para imagem ótica. / Nanocarriers systems of organic molecules have emerged as promising systems for application in therapy and diagnosis. In the present study polymeric nanocapsules containing fluorescent probes in their different domains, capable of providing image when analyzed in confocal fluorescence microscope, showing the potential of the system as an agent for optical imaging. An important feature of proposed molecules as fluorescent probes, there is no overlap of the spectra of absorption and fluorescence emission. Thus, a group of synthetic dye benzoxazólicos (HBO-C8) to mark the lipophilic core, and PCL and chitosan polymers were covalently linked to dye rhodamine B and acridine orange , respectively. The formulations developed and characterized with two or three markers showed nanotechnological character and transmission photomicrographs showed that nanoparticles containing PCL-Rho and HBO-C8 (without chitosan) preserved morphology of the nanoparticle. Additionally, the HBO-C8 was was quantified on formulation contained HBO-C8 and PCL-Rho, where it was found that 98% of the dye is internalized in the nanoparticle thus reaching the purpose proposed to use as a probe for marking the lipophilic core . By images of confocal fluorescence microscopy were obtained the colocalized of fluorescent markers to formulations containing two or three fluorescent domains, demonstrating that these nanocapsules can be proposed as a promising platform to be used as probes for optical image.
14

Análise experimental de copolímero na estabilidade primária de implantes osseointegráveis : avaliação microscópica em ratos /

Kayatt, Fernando Esgaib. January 2006 (has links)
Orientador: Idelmo Rangel Garcia Júnior / Banca: Roberta Okamoto / Banca: Luiz Antônio Salata / Banca: Antonio Carlos Guastaldi / Banca: Paulo Sérgio Perri de Carvalho / Resumo: A estabilidade primária na instalação de implantes dentários é uma das determinantes principais no processo de osseointegração. Algumas situações clínicas impossibilitam o travamento adequado do implante. A diástase provocada por sobrefresagem ou implantações pós-exodônticas indicam o uso de materiais para ocupar este espaço. O objetivo deste estudo foi analisar o uso de copolímero a base de ácido poliláctico na estabilidade primária de implantes osseointegráveis, realizando uma avaliação microscópica através de fluorocromos. Para isso, foram utilizados 14 cilindros de Ti cp GII instalados na tíbia de ratos, divididos em: Grupo Implante Travado (GIT) e Grupo Implante e Biomaterial (GIB), nos períodos de 7, 15 e 21 dias. Resultado: Os implantes suportaram 3N.cm de torque reverso e não foram encontradas diferenças estatisticamente significantes, nos períodos finais, entre as médias das áreas ao redor do implante. O copolímero de PLA/PGA proporcionou o posicionamento dos implantes e não obstou a deposição óssea. / Abstract: The primary stability in the installation of dental implants is one of the main prerequisite in the osseointegration process. Some clinical situations disable the adequate stability of the implantation. A gap occurred between the bone and the implant provoked by overdrilling or tooth extractions sockets implantations indicates the use of biomaterials to occupy this space. The aim of this study was to analyze the use of PLA/PGA copolymer in the primary stability of osseointegrated implants, through removal torque test and a microscopic evaluation with fluorescent bone markers. For this, 14 cylinders of Ti cp GII had been installed in the tibia of rats, divided in: Group Implant with Stability (GIT) and Group Implant and Biomaterial (GIB), in the periods of 7, 15 and 21 days. Result: The implantations had supported 3N.cm of removal torque and had not been found differences statistically significant, in the final periods, between the averages of the areas of the periphery of the implants. The PLA/PGA copolymer kept the implants position and did not hinder the bone deposition. / Doutor
15

Marcação fluorescente de cálcio em tecidos de suporte após a movimentação dentária experimental em ratos

Shimabucoro, Carlos Eduardo [UNESP] 14 January 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-01-14Bitstream added on 2014-06-13T19:07:00Z : No. of bitstreams: 1 shimabucoro_ce_me_araca.pdf: 644965 bytes, checksum: 4c0994e094a9206c065633ccadc5a2cf (MD5) / O osso alveolar, como os demais ossos, é continuamente remodelado por processo que equilibra reabsorção óssea por osteoclastos seguido pela deposição óssea por osteoblastos. A aplicação de forças ortodônticas gera reações locais nos tecidos relacionados com a dentição e oclusão bem como em fatores sistêmicos relacionados com o metabolismo ósseo, como a concentração de cálcio, fósforo e fosfatase alcalina. O nosso objetivo foi identificar, através de marcadores fluorescentes, a deposição de cálcio no ligamento periodontal e analisar a concentração plasmática de cálcio, fósforo e fosfatase alcalina antes e após a movimentação dentária experimental. A movimentação foi realizada com aparelhos instalados no primeiro molar superior em ratos machos (Wistar/250g). Os animais receberam três injeções de marcadores ósseos fluorescentes, na seguinte ordem: calceína, alizarina e oxitetraciclina com intervalo de sete dias entre as injeções para análise de 17 (G1), 28 (G2) ou 35 (G3) dias após instalação do aparelho. Sete dias após a última injeção, o sangue foi coletado e centrifugado para a realização posterior das análises bioquímicas. As maxilas foram retiradas, limpas e submetidas aos procedimentos específicos para o preparo das lâminas e leitura posterior em microscópio de epifluorescência. Foi coletado sangue de oito animais que não receberam intervenção ortodôntica, para controle das concentrações plasmáticas. A análise qualitativa evidenciou diferença entre o lado controle e o submetido à movimentação dentária, entretanto, a análise quantitativa não constatou diferença estatisticamente significante. As leituras espectrofotométricas nas dosagens dos plasmas destes animais mostraram concentração de cálcio sem diferença estatística entre os grupos. / The alveolar bone, as the other bones, continuously is remodelled by process that balances bone resorption by osteoclasts followed by the bone deposition for osteoblasts. The application of orthodontic forces generates local reactions in tissues related to the teeth and occlusion as well as systemic factors related with the bone metabolism, as the concentration of calcium, phosphorus and alkaline phosphatase. Our objective was to identify, through fluorescent markers, the calcium deposition in the periodontal ligament and to analyze the plasma concentration of calcium, phosphorus and alkaline phosphatase before and after the experimental tooth movement. The movement was performed with apparatus installed on the upper first the molar superior in male rats (Wistar/250g). These animals received three injections of bone fluorescent markers, in the following order: calcein, alizarin and oxytetracycline with interval of seven days between the injections for analysis of 17 (G1), 28 (G2) or 35 (G3) days after installation of the unit. Seven days after the last injection, the blood was collected and centrifuged to the achievement of subsequent biochemical analyses. The jaws had been removed, cleaned and submitted to the specific procedures for the preparation of the slides and posterior reading in the epifluorescence microscopy. Blood of eight animals that had not received intervention orthodontic, for control of the plasmatic concentrations was collected. The qualitative analysis evidenced difference between the side control and the submitted to the tooth movement, however, the quantitative analysis did not evidence significant difference statistical. The spectrophotometric readings in the dosages of plasmas of these animals had shown to calcium concentration without difference statistics between the groups. However, the analysis of the phosphorus evidenced co-relation between the plasmatic concentration and the time of tooth movement.
16

Obtenção de materiais orgânicos conjugados com corantes fluorescentes para a marcação de nanocápsulas poliméricas com potencial aplicação em diagnóstico e terapêutica

Prado, Willian Andrade January 2014 (has links)
Sistemas nanocarreadores de moléculas orgânicas têm emergido como promissores sistemas para aplicação na terapêutica e/ou diagnóstico. No presente trabalho foram desenvolvidas nanocápsulas poliméricas contendo, em seus diferentes domínios, sondas fluorescentes capazes de fornecer imagem quando analisadas em microscópio de fluorescência confocal, mostrando as potencialidades do sistema como agente para imagem ótica. Uma importante característica de moléculas propostas como marcadores fluorescentes, é que não haja sobreposição dos espectros de absorção e emissão de fluorescência. Para tanto, foi utilizado um corante sintético do grupo dos benzoxazólicos (HBO-C8) para marcação do núcleo lipofílico, e os polímeros PCL e quitosana foram ligados covalentemente aos corantes rodamina B e alaranjado de acridina, respectivamente. As formulações desenvolvidas e caracterizadas com dois ou três marcadores apresentaram caráter nanotecnológico e as fotomicrografias de transmissão revelaram que as nanopartículas contendo HBO-C8 e PCL-Rho (sem quitosana), preservou a morfologia da nanopartícula. Adicionalmente, o HBO-C8 foi quantificado na formulação contendo HBO-C8 e PCL-Rho, onde verificou-se que 98% do corante está internalizado na nanopartícula, alcançando assim, o objetivo proposto de usá-lo como sonda para marcação do núcleo lipofílico. Por meio da microscopia de fluorescência confocal, foram obtidas imagens dos marcadores fluorescentes colocalizados, para as formulações contendo dois ou três domínios fluorescentes, demonstrando que essas nanocápsulas podem ser propostas como uma plataforma promissora para serem empregadas como sondas para imagem ótica. / Nanocarriers systems of organic molecules have emerged as promising systems for application in therapy and diagnosis. In the present study polymeric nanocapsules containing fluorescent probes in their different domains, capable of providing image when analyzed in confocal fluorescence microscope, showing the potential of the system as an agent for optical imaging. An important feature of proposed molecules as fluorescent probes, there is no overlap of the spectra of absorption and fluorescence emission. Thus, a group of synthetic dye benzoxazólicos (HBO-C8) to mark the lipophilic core, and PCL and chitosan polymers were covalently linked to dye rhodamine B and acridine orange , respectively. The formulations developed and characterized with two or three markers showed nanotechnological character and transmission photomicrographs showed that nanoparticles containing PCL-Rho and HBO-C8 (without chitosan) preserved morphology of the nanoparticle. Additionally, the HBO-C8 was was quantified on formulation contained HBO-C8 and PCL-Rho, where it was found that 98% of the dye is internalized in the nanoparticle thus reaching the purpose proposed to use as a probe for marking the lipophilic core . By images of confocal fluorescence microscopy were obtained the colocalized of fluorescent markers to formulations containing two or three fluorescent domains, demonstrating that these nanocapsules can be proposed as a promising platform to be used as probes for optical image.
17

Testes fluorimétricos na sorologia da toxoplasmose humana: detecção simultânea de anticorpos de IgG e IgM específicos / Fluorimetric immunoassay in human toxoplasmosis: simultaneous detection of specific IgG and IgM antibodies

Jaqueline Polizeli Rodrigues 14 February 2014 (has links)
A toxoplasmose, protozoose disseminada de baixa morbidade, apresenta número significativo de doença ocular, congênita ou do sistema nervoso central. O diagnóstico é sorológico por diferentes testes, mas limiares baixos e variação individual levam a frequentes problemas. Novos imunoensaios fluorescentes de fase sólida (FLISA) usam a quantificação direta de anticorpos. Aqui, desenvolvemos um FLISA multiplex (FLISAm) para a detecção simultânea de anticorpos IgG e IgM contra Toxoplasma gondii. Após padronização, a eficiência do FLISAm com conjugados comerciais foi feita inicialmente de forma isolada para cada imunoglobulina em 140 amostras de soro de universitários previamente analisadas pelo ELISA IgG/IgM. FLISA IgG mostrou boa concordância (Kappa=0,7088), com sensibilidade de 83,3% e especificidade de 94,2%, enquanto FLISA IgM apresentou boa concordância (K=0,6026), menor sensibilidade de 55,5% e igual especificidade de 98,4%. Foram produzidos novos conjugados fluorescentes de maior especificidade e seu desempenho no FLISAm foi validado em 24 amostras e sua eficiência foi avaliada em 120 amostras conhecidas de soro de gestantes. FLISAm mostrou excelente concordância, tanto para a detecção de anticorpos IgG (K=0.8837, sensibilidade=100,0%, especificidade=87,5%), quanto para a detecção de anticorpos IgM (K=0,9187, sensibilidade=100%, especificidade=99,1%) com excelente reprodutibilidade. O teste desenvolvido é rápido, econômico, de fácil execução, alto rendimento e que pode ser utilizado como método de triagem de soroconversão em mulheres grávidas, útil em aplicações de grande número de amostras como o cuidado pré-natal. / Toxoplasmosis, a disseminated low morbidity protozoan disease, presented significant numbers of affected people, mainly ocular disease, fetal infections or encephalitis in immune deficient patients. Serology is the main diagnosis with commercial antibody assays, but individual variation or low thresholds cause many inconsistencies. New solid phase immunofluorescence assays (FLISA) allows direct antibody quantification in microplates. Here, we developed a multiplex FLISA (FLISAm) for simultaneous detection of IgG and IgM anti-Toxoplasma gondii antibodies. After standardization, the efficiency of this method was initially analyzed in isolated FLISA for each immunoglobulin with commercial conjugates in 140 serum samples of the students previously screened by IgG/IgM ELISA. IgG FLISA showed good concordance (Kappa=0.7088), 83,3% sensitivity and 94,2% specificity, while IgM FLISA also showed good concordance (Kappa=0,6026), lower 55,5% sensitivity and similar 98,4% specificity. New higher efficiency conjugated were prepared and tested in 120 serum samples of the pregnant woman in a same well conjunct IgG/IgM FLISAm. We also validate the FLISAm in 24 serum samples. Compared to isolated ELISA IgG/IgM, FLISAm demonstrated excellent concordance for IgG (Kappa=0.8837; sensitivity=100%; specificity=87,5%,) and IgM (Kappa=0,9187; sensitivity=100%; specificity=99,1%), with excellent reproducibility. The standardized FLISAm is quick, inexpensive, easily performed and high throughput and the assay can be used for screening serum conversion in pregnant women, useful in large numbers applications as antenatal care.
18

Análise do efeito de adição do marcador Rodamina B em propriedades mecânicas de sistemas adesivos não simplificados / Analysis of the effect of addition of Rhodamine B marker on mechanical properties of non-simplified adhesives

Camila Moreira Machado 12 December 2014 (has links)
Este estudo in vitro avaliou o efeito da adição de rodamina B dissolvida em etanol nas concentrações de 0,02mg/mL e 0,10mg/mL, nas propriedades mecânicas dos sistemas adesivos não simplificados considerados padrão-ouro. 96 coroas de terceiros molares humanos hígidos foram seccionadas transversalmente no terço oclusal para remoção do esmalte e exposição da dentina. Os espécimes foram divididos de acordo com os sistemas adesivos Adper Scotchbond Multi-Purpose (MP) - convencional de três passos ou Clearfil SE Bond (SE) - autocondicionante de dois passos: MP-C e SE-C (MP e SE controles); MP-C1 e SE-C1 (MP e SE com rodamina B 0,02mg/mL); MP-C2 e SE-C2: (MP e SE com rodamina B 0,10mg/mL). Para o teste de RU, os espécimes (n=10) foram submetidos ao desgaste com lixas de granulação 320 e 600. A dentina foi tratada de acordo com as instruções de cada fabricante dos sistemas adesivos e restaurada com resina composta FiltekTM Z250. Após o armazenamento em saliva artificial (7dias/37oC), os espécimes foram seccionados para obtenção de palitos com 0,64 mm2 de área média e submetidos ao teste de microtração em máquina de teste universal a 0,5 mm/min, que foram analisados após 7 dias e 6 meses. O modo de fratura dos espécimes foi analisado com estereomicroscópio digital (x200) e classificado em: adesiva, coesiva em dentina, coesiva em resina e mista. Para o teste de MS, as coroas seccionadas (n=6) foram planificadas com lixa de granulação 600. A dentina foi tratada de acordo com as instruções de cada fabricante dos sistemas adesivos e os espécimes foram mantidos secos em estufa a 37oC durante 48 horas. O teste de MS foi realizado utilizando ponta Knoop (Microdurômetro Shimadzu HMV-2), a 10x e carga estática de 25gF por 10 segundos. Os resultados obtidos foram analisados por análise de variância (ANOVA-2 critérios) e teste de Bonferroni para comparações múltiplas (p<0,05). A análise de acordo com o tempo foi realizada com o teste de t-student. Os valores médios de RU e desvio padrão (MPa±dp; 7 dias / 6 meses) foram: MP-C (41,95±2,38 / 22,76±3,66); MP-C1 (28,02±5,12 / 17,93±5,70); MP-C2 (26,28±5,55 / 14,30±5,68); SE-C (46,07±1,43 / 19,07±6,75); SE-C1 (37,49±13,31 / 18,54±6,71); SE-C2 (34,16±7,71 / 17,89±4,87). No tempo de 7 dias, os fatores sistema adesivo e concentração de rodamina B foram significantes. Após 6 meses, apenas o fator concentração de rodamina B foi significante. A falha de fratura predominante em todos os grupos foi adesiva. Os valores de MS (KHN) e desvio padrão foram: MP-C (8,97±3,85); MP-C1 (7,33±0,99); MP-C2 (7,17±2,45); SE-C (4,71±4,42); SE-C1 (4,42±0,56); SE-C2 (3,27±0,30). Na comparação entre os sistemas adesivos, eles diferiram entre si na condição controle e de 0,10mg/mL. Para cada adesivo, não houve diferença entre as distintas condições de acordo com a adição de rodamina B. Em função dos resultados apresentados, a adição de rodamina B nos sistemas adesivos não simplificados MP e SE, nas concentrações de 0,02mg/mL e 0,10mg/mL, deve ser incorporada com cautela para que não influencie nas propriedades mecânicas do material. / This in vitro study evaluated the effect of addition of rhodamine B dissolved in ethanol in concentrations of 0.02mg/mL and 0.10mg/mL, the mechanical properties of non-simplified adhesive systems. 96 crowns of human third molars were transversely sectioned on the oclusal third to remove the enamel and exposure the dentin. The specimens were divided according to the adhesive systems Adper Scotchbond Multi-Purpose (MP) 3-step-etch-andrinse or Clearfil SE Bond (SE) 2-step-self-ecthing: MP-C and SE-C (MP and SE controls); MP-C1 and SE-C1 (MP and SE with 0.02mg/mL rhodamine B); MP-C2 and SE-C2: (MP and SE with 0.10mg/mL rhodamine B). For the &#x3BC;TBS test, the specimens (n=10) were ground with 320- to 600-grit silicon carbide paper. The dentin was treated according to the instructions of each manufacturer and restored with composite resin FiltekTM Z250. The specimens were stored in artificial saliva (7 days/37oC), and then sectioned to obtain sticks with an average of 0.64 mm2 area and submitted to &#x3BC;TBS test at a universal testing machine at 0.5 mm/min, which were analyzed immediately after 7 days and 6 months. The mode of fracture of the specimens was analyzed with digital stereomicroscope (x200) and classified as: adhesive, cohesive in dentine, cohesive in resin and mixed. For the SM test, the sectioned crowns (n=6) were flattened with 600-grit silicon carbide paper. The dentin was treated according to the manufacturers instructions for each adhesive system and the specimens were stored in dry condition at 37oC during 48 hours. The SM test was performed with Knoop indenter (Shimadzu HMV-2 hardness tester), at 10x and 25gF of load for 10 seconds. The results were analyzed by two-way analysis of variance tests and the Bonferroni test for multiple comparisons (p<0.05). The analysis regarding time was checked with t-student test. The mean &#x3BC;TBS and standard deviation (MPa±dp; 7 days / 6 months) were: MP-C (41.95±2.38 / 22.76±3.66); MP-C1 (28.02±5.12 / 17.93±5.70); MP-C2 (26.28±5.55 / 14.30±5.68); SE-C (46.07±1.43 / 19.07±6.75); SE-C1 (37.49±13.31 / 18.54±6.71); SE-C2 (34.16±7.71 / 17.89±4.87). In the immediate time, the adhesive system and rhodamine B concentration factors were significant. After 6 months, only the rhodamine B concentration was a significant factor. The predominant failure in all groups was adhesive. The values of SM and standard deviation were: MP-C (8.97±3.85); MP-C1 (7.33±0.99); MP-C2 (7.17±2.45); SE-C (4.71±4.42); SE-C1 (4.42±0.56); SE-C2 (3.27±0.30). In the comparison between the adhesive systems, they were significantly different for the conditions control and 0.10mg/mL. For each adhesive systems, there was no difference between the different conditions according to the addition of rhodamine B. Regarding the shown results, addition of rodhamine B in non-simplified adhesives MP and SE, in the concentrations of 0.02mg/mL e 0.10mg/mL must be carefully added to avoid implications to the mechanical properties of the materials.
19

Obtenção de materiais orgânicos conjugados com corantes fluorescentes para a marcação de nanocápsulas poliméricas com potencial aplicação em diagnóstico e terapêutica

Prado, Willian Andrade January 2014 (has links)
Sistemas nanocarreadores de moléculas orgânicas têm emergido como promissores sistemas para aplicação na terapêutica e/ou diagnóstico. No presente trabalho foram desenvolvidas nanocápsulas poliméricas contendo, em seus diferentes domínios, sondas fluorescentes capazes de fornecer imagem quando analisadas em microscópio de fluorescência confocal, mostrando as potencialidades do sistema como agente para imagem ótica. Uma importante característica de moléculas propostas como marcadores fluorescentes, é que não haja sobreposição dos espectros de absorção e emissão de fluorescência. Para tanto, foi utilizado um corante sintético do grupo dos benzoxazólicos (HBO-C8) para marcação do núcleo lipofílico, e os polímeros PCL e quitosana foram ligados covalentemente aos corantes rodamina B e alaranjado de acridina, respectivamente. As formulações desenvolvidas e caracterizadas com dois ou três marcadores apresentaram caráter nanotecnológico e as fotomicrografias de transmissão revelaram que as nanopartículas contendo HBO-C8 e PCL-Rho (sem quitosana), preservou a morfologia da nanopartícula. Adicionalmente, o HBO-C8 foi quantificado na formulação contendo HBO-C8 e PCL-Rho, onde verificou-se que 98% do corante está internalizado na nanopartícula, alcançando assim, o objetivo proposto de usá-lo como sonda para marcação do núcleo lipofílico. Por meio da microscopia de fluorescência confocal, foram obtidas imagens dos marcadores fluorescentes colocalizados, para as formulações contendo dois ou três domínios fluorescentes, demonstrando que essas nanocápsulas podem ser propostas como uma plataforma promissora para serem empregadas como sondas para imagem ótica. / Nanocarriers systems of organic molecules have emerged as promising systems for application in therapy and diagnosis. In the present study polymeric nanocapsules containing fluorescent probes in their different domains, capable of providing image when analyzed in confocal fluorescence microscope, showing the potential of the system as an agent for optical imaging. An important feature of proposed molecules as fluorescent probes, there is no overlap of the spectra of absorption and fluorescence emission. Thus, a group of synthetic dye benzoxazólicos (HBO-C8) to mark the lipophilic core, and PCL and chitosan polymers were covalently linked to dye rhodamine B and acridine orange , respectively. The formulations developed and characterized with two or three markers showed nanotechnological character and transmission photomicrographs showed that nanoparticles containing PCL-Rho and HBO-C8 (without chitosan) preserved morphology of the nanoparticle. Additionally, the HBO-C8 was was quantified on formulation contained HBO-C8 and PCL-Rho, where it was found that 98% of the dye is internalized in the nanoparticle thus reaching the purpose proposed to use as a probe for marking the lipophilic core . By images of confocal fluorescence microscopy were obtained the colocalized of fluorescent markers to formulations containing two or three fluorescent domains, demonstrating that these nanocapsules can be proposed as a promising platform to be used as probes for optical image.
20

Use of fluorescence in the performance evaluation of adhesive systems = Uso da fluorescência na avaliação do comportamento de sistemas adesivos / Uso da fluorescência na avaliação do comportamento de sistemas adesivos

Araújo, Cíntia Tereza Pimenta de, 1968- 21 August 2018 (has links)
Orientador: Luis Alexandre Maffei Sartinni Paulillo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T22:09:59Z (GMT). No. of bitstreams: 1 Araujo_CintiaTerezaPimentade_D.pdf: 9367664 bytes, checksum: 6c7161dae0f158a143f829e530249b20 (MD5) Previous issue date: 2013 / Resumo: A microscopia confocal de varredura a laser (MCVL) é um recurso de visualização microscópica que permite a análise de materiais ou estruturas com requisitos mínimos de preparação de amostras de modo não destrutivo. Assim, os objetivos deste estudo foram: avaliar a influência da incorporação do corante fluorescente Rodamina B (R) nas propriedades mecânicas resistência coesiva (RC), módulo de elasticidade (ME) e resistência à flexão (RF) de 2 sistemas adesivos, o autocondicionante Clearfil SE Bond e o convencional Scotchbond Multi-Purpose (estudo 1); validar o método modificado de microtração (?TBS), em que micro-amostras de secção transversal de 0,09 mm2 foram testadas e verificar a influência da R na resistência à união a dentina e integridade interfacial através de microscopia confocal (estudo 2). Para avaliar a influência do corante, 0,16 mg/ml de R foram incorporados aos adesivos constituindo assim dois grupos para cada adesivo: grupos dos adesivos corados e não corados totalizando 4 grupos experimentais. Para a análise da RC, E e RF, os corpos de prova foram confeccionados a partir de uma matriz de silicone por adição. Sobre a matriz, foram dispensados 10 ?L de adesivo variando de acordo com cada grupo de adesivos corados e não corados. RC (n= 10), E e RF (n= 5) foram avaliadas em máquina de ensaio universal a 0,5 mm/min, até a ruptura da amostra. Para visualização em microscopia confocal e análise da resistência à união os adesivos foram aplicados à superfície plana da dentina oclusal de 32 pré-molares humanos. Após a realização dos procedimentos adesivos, realizaram-se as restaurações (blocos de 16 mm2) com Charisma Opal (Kulzer - cor A3). Em seguida, para a realização do teste modificado de microtração, micro-amostras em forma de palito (secção transversal 0,09 mm2) foram confeccionadas. Previamente ao ensaio mecânico, foi realizada através de MVCL a análise micromorfológica das microamostras dos grupos de adesivos corados. Posteriormente a resistência à união foi mensurada através do ensaio modificado de microtração a velocidade de 0,5 mm/min em máquina de ensaio universal. Os dados de todos os testes avaliados foram submetidos à análise de variância dois fatores. Os resultados mostraram que o comportamento dos sistemas adesivos investigados não se modificou, independente da presença do corante, pois não foram observadas diferenças significativas nas propriedades mecânicas estudadas: resistência à união, resistência coesiva, resistência flexural, módulo de elasticidade, bem como a integridade interfacial. A preparação de micro-amostras não comprometeu os resultados do ensaio de resistência adesiva. De acordo com os resultados obtidos e análise dos parâmetros: coeficiente de variação, porcentagem de padrão de fratura e incidência de falhas prematuras, concluiu-se que o teste modificado de microtração foi considerado um método confiável para a avaliação da resistência à união de sistemas adesivos. A técnica de visualização microscópica confocal produziu informações detalhadas da interface adesiva e pode ser bem indicada para a avaliação da efetividade de união de sistemas adesivos. Desta forma, é possível associar ambas as metodologias obtendo-se uma avaliação mais realista e confiável dos materiais restauradores / Abstract: The confocal laser scanning microscopic (CLSM) is a tool of visualization that allows microscopic analysis of materials or structures labeled with fluorescent dyes with minimal requirements of specimen's preparation nondestructively. The aims of this study were: to evaluate the influence of incorporation of fluorescent dye Rhodamine B (R) in the properties mechanical: cohesive strength (CS), elastic modulus (E) and flexural strength (FS) of the selfetching Clearfil SE Bond and etch-and-rinse Scotchbond Multi-Purpose (Study 1); validating the modified microtensile method using micro-specimens cross section of 0.09 mm2 (?TBS) and evaluate the influence of R in bond strength in dentin and interfacial integrity by confocal microscopy (study 2). To evaluate the influence of the dye, 0.16 mg/ml of R were incorporated into adhesives thus forming two groups for each adhesive: groups of labeled adhesives and no-labeled totaling 4 experimental groups. For the analysis of CS, E and FS the specimens were made from a silicone matrix. About the matrix were 10 ?L dispensed adhesive varying according to each group of adhesives stained or not. CS (n = 10), E and FS (n = 5) were evaluated in a universal testing machine at 0.5 mm/min until failure of the specimen. For visualization in confocal microscopy and bond strength analysis (n = 8), the adhesives were applied to the occlusal dentine surface 32 of human premolars. After procedures adhesives, composite crowns approximately (16 mm2) were built up with Charisma Opal (Kulzer - color A3). Then for testing modified microtensile, micro-specimens beam-shaped were prepared. Prior to mechanical testing micromorphological analysis of micro-sticks of the groups of labeled adhesives was performed using CLSM. Subsequently bond strength was measured using the modified microtensile test in a universal testing machine speed of 0.5 mm/min. The results showed that the behavior of the adhesive systems investigated did not change regardless of the presence of the dye, as there were no significant differences in mechanical properties studied: bond strength, tensile strength, flexural strength, modulus of elasticity, as well as interfacial integrity. The preparation of micro-specimens did not affect the results of the bond strength test. According to the analysis results and parameters: coefficient of variation percentage of fracture pattern and incidence of early failures, it is concluded that the modified microtensile test was considered a reliable method for evaluating the bond strength of adhesive systems. The confocal microscopic visualization technique yielded detailed information of the adhesive interface and can be well suited for evaluating the effectiveness of adhesive systems. Thus, it is possible to associate both methods give a more realistic and reliable adhesive restoration on the presence of fluorescent dye / Doutorado / Dentística / Doutora em Clínica Odontológica

Page generated in 0.091 seconds