• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Deformações geradas no intermediário e região peri-implantar após aplicação de cargas inclinadas em coroas unitárias

Albarracín, Max Laurent 31 July 2015 (has links)
A reabilitação protética de pacientes desdentados é uma área da Odontologia amplamente estudada por pesquisadores do mundo todo, e com o desenvolvimento dos implantes osseointegrados surgiram muitas perguntas sobre o desempenho das próteses instaladas sobre estes. Conhecer o comportamento mecânico do conjunto coroa unitária, intermediário, implante e tecido de suporte é importante para entender o processo de transmissão de forças e suas consequências, processos estes que ainda não estão totalmente compreendidos. O objetivo deste trabalho foi verificar a deformação gerada no intermediário e no osso peri-implantar após aplicação de uma carga inclinada sobre coroas unitárias metalocerâmicas. Foi utilizado um modelo mestre de poliuretano, simulando o osso mandibular, com um implante hexágono externo de 3,75mm x13 mm de comprimento, no qual foi fixado um intermediário multi-unit. O trabalho foi realizado com 3 grupos de 4 coroas cada, divididos de acordo com o tipo de cilindro e liga de fundição (cilindros de ouro sobrefundidos com liga de PdAg, cilindro de acrílico fundido com liga de NiCoCr e cilindros de CoCr usinado sobrefundidos com liga de NiCoCr). Cada corpo de prova foi submetido cinco vezes à aplicação de carga oblíqua de 15 e 30 graus no centro da oclusal de cada coroa com uma força de 300N em uma máquina universal de ensaios. Foram realizadas leituras das deformações geradas no intermediário e no poliuretano, com o uso de extensômetros lineares elétricos (strain gauges) os quais foram colados em três faces do intermediário (Disto lingual, Mesio lingual, Vestibular) e nas superfícies mesial, vestibular, distal e lingual do osso simulado ao redor do implante. Os dados obtidos foram submetidos à análise de variância a 3 critérios (ANOVA) e o teste de Tukey, utilizando um nível de significância (p<0,05). Os resultados mostraram que entre as duas angulações utilizadas existiram diferenças estatísticas significantes. Os valores médios de deformação se mantiveram dentro dos padrões de normalidade, na janela fisiológica descrita por Frost entre 50 &#x3BC;&#x3B5; e 1500 &#x3BC;&#x3B5; independente do tipo de cilindro utilizado, com exceção dos valores de compressão obtidos na carga oblíqua de 30 graus onde nos três tipos de cilindro ultrapassaram a janela de sobrecarga patológica com mais de 4000 &#x3BC;&#x3B5. / The prosthetic rehabilitation of edentulous patients is a dental area widely studied by worldwide researchers, and through the development of dental implants, appear many questions about the performance of prostheses installed on them. Knowledge of the mechanical behavior of the integration between single crown, abutment, implant and support tissue is very important to understand the forces transmission process and its consequences but these processes are not fully understood. The objective of the present study was to evaluate the deformation generated in the abutment and simulated peri-implant bone after application of an oblique load on metal-ceramic crowns. A polyurethane master model was used to simulate the jawbone with an implant external hexagon 3.75 mm x13 mm length, which was fixed in a multi-unit abutment. The study was conducted with twelve metal ceramic crowns divided according to type of cylinder and casting alloy, Group 1: Gold cylinder cast with PdAg alloy; Group 2: Acrylic cylinder cast with NiCoCr alloy; Group 3: CoCr cylinder cast with NiCoCr alloy, thus forming three groups of four sample each. Each specimen was subjected five times the application of oblique load of 15 and 30 degrees in the center of the occlusal of each crown with a 300N force in a universal testing machine. Readings were taken of the deformations generated in the abutment and bone simulated by polyurethane, with the use of electric linear strain gauges which have been positioned on three sides equidistant to each other to measure microstrains at abutment (disto-lingual, meso-lingual, Vestibular) and the simulated bone around each implant received four strain gauges, positioned on the mesial, distal, buccal and lingual aspects. The data were submitted to analysis of variance to 3 criteria (ANOVA) and Tukey test, using a significance level (p <0.05). The results showed that between the two angles tested there were significant statistical differences. The deformation average values remained within normal limits, at the adapted state described by Frost between 50 &#x3BC;&#x3B5 and 1500 &#x3BC;&#x3B5 independent of the type of cylinder used, with the exception of compression values in oblique load of 30 degrees where the three types of cylinder surpassed the pathological overhead state with over 4,000 &#x3BC;&#x3B5.
2

Deformações geradas no intermediário e região peri-implantar após aplicação de cargas inclinadas em coroas unitárias

Max Laurent Albarracín 31 July 2015 (has links)
A reabilitação protética de pacientes desdentados é uma área da Odontologia amplamente estudada por pesquisadores do mundo todo, e com o desenvolvimento dos implantes osseointegrados surgiram muitas perguntas sobre o desempenho das próteses instaladas sobre estes. Conhecer o comportamento mecânico do conjunto coroa unitária, intermediário, implante e tecido de suporte é importante para entender o processo de transmissão de forças e suas consequências, processos estes que ainda não estão totalmente compreendidos. O objetivo deste trabalho foi verificar a deformação gerada no intermediário e no osso peri-implantar após aplicação de uma carga inclinada sobre coroas unitárias metalocerâmicas. Foi utilizado um modelo mestre de poliuretano, simulando o osso mandibular, com um implante hexágono externo de 3,75mm x13 mm de comprimento, no qual foi fixado um intermediário multi-unit. O trabalho foi realizado com 3 grupos de 4 coroas cada, divididos de acordo com o tipo de cilindro e liga de fundição (cilindros de ouro sobrefundidos com liga de PdAg, cilindro de acrílico fundido com liga de NiCoCr e cilindros de CoCr usinado sobrefundidos com liga de NiCoCr). Cada corpo de prova foi submetido cinco vezes à aplicação de carga oblíqua de 15 e 30 graus no centro da oclusal de cada coroa com uma força de 300N em uma máquina universal de ensaios. Foram realizadas leituras das deformações geradas no intermediário e no poliuretano, com o uso de extensômetros lineares elétricos (strain gauges) os quais foram colados em três faces do intermediário (Disto lingual, Mesio lingual, Vestibular) e nas superfícies mesial, vestibular, distal e lingual do osso simulado ao redor do implante. Os dados obtidos foram submetidos à análise de variância a 3 critérios (ANOVA) e o teste de Tukey, utilizando um nível de significância (p<0,05). Os resultados mostraram que entre as duas angulações utilizadas existiram diferenças estatísticas significantes. Os valores médios de deformação se mantiveram dentro dos padrões de normalidade, na janela fisiológica descrita por Frost entre 50 &#x3BC;&#x3B5; e 1500 &#x3BC;&#x3B5; independente do tipo de cilindro utilizado, com exceção dos valores de compressão obtidos na carga oblíqua de 30 graus onde nos três tipos de cilindro ultrapassaram a janela de sobrecarga patológica com mais de 4000 &#x3BC;&#x3B5. / The prosthetic rehabilitation of edentulous patients is a dental area widely studied by worldwide researchers, and through the development of dental implants, appear many questions about the performance of prostheses installed on them. Knowledge of the mechanical behavior of the integration between single crown, abutment, implant and support tissue is very important to understand the forces transmission process and its consequences but these processes are not fully understood. The objective of the present study was to evaluate the deformation generated in the abutment and simulated peri-implant bone after application of an oblique load on metal-ceramic crowns. A polyurethane master model was used to simulate the jawbone with an implant external hexagon 3.75 mm x13 mm length, which was fixed in a multi-unit abutment. The study was conducted with twelve metal ceramic crowns divided according to type of cylinder and casting alloy, Group 1: Gold cylinder cast with PdAg alloy; Group 2: Acrylic cylinder cast with NiCoCr alloy; Group 3: CoCr cylinder cast with NiCoCr alloy, thus forming three groups of four sample each. Each specimen was subjected five times the application of oblique load of 15 and 30 degrees in the center of the occlusal of each crown with a 300N force in a universal testing machine. Readings were taken of the deformations generated in the abutment and bone simulated by polyurethane, with the use of electric linear strain gauges which have been positioned on three sides equidistant to each other to measure microstrains at abutment (disto-lingual, meso-lingual, Vestibular) and the simulated bone around each implant received four strain gauges, positioned on the mesial, distal, buccal and lingual aspects. The data were submitted to analysis of variance to 3 criteria (ANOVA) and Tukey test, using a significance level (p <0.05). The results showed that between the two angles tested there were significant statistical differences. The deformation average values remained within normal limits, at the adapted state described by Frost between 50 &#x3BC;&#x3B5 and 1500 &#x3BC;&#x3B5 independent of the type of cylinder used, with the exception of compression values in oblique load of 30 degrees where the three types of cylinder surpassed the pathological overhead state with over 4,000 &#x3BC;&#x3B5.
3

Avaliação da deformação do intermediário e região peri-implantar em função da carga aplicada em coroas unitárias implantossuportadas parafusadas / Evaluation of the deformation in the abutment and peri-implant region according to the load applied in screwed implant-supported single crowns

Albarracín, Max Laurent 30 May 2011 (has links)
As coroas unitárias metalocerámicas implantossuportadas são amplamente utilizadas na reabilitação de pacientes desdentados. O comportamento mecânico destas coroas é muito importante para entender o processo de transmissão de forças mastigatórias e suas reações no intermediário e na estrutura óssea peri-implantar, mas estes processos ainda não estão totalmente compreendidos. O objetivo deste trabalho foi verificar a deformação gerada no intermediário e no osso peri-implantar de coroas unitárias implantossuportadas após aplicação de carga. Foi utilizado um modelo mestre de poliuretano, simulando o osso mandibular, com um implante hexágono externo de 3,75mm x13 mm de comprimento, no qual foi fixado um intermediário multi-unit (Nobel Biocare, Göteborg, Sweden). O trabalho apresentou 3 grupos com quatro corpos de prova cada, divididos de acordo com o tipo de cilindro e liga de fundição (Cilindro de ouro sobrefundidos com a liga de PdAg, cilindro de CoCr usinado sobrefundidos com a liga de NiCoCr, cilindro de acrílico fundido com a liga de NiCoCr ). Cada corpo de prova foi submetido cinco vezes a aplicação de carga axial de 300N em uma máquina de ensaio universal. A força foi aplicada no centro da oclusal de cada coroa. Foram realizadas leituras das deformações geradas no intermediário e no poliuretano com o uso de extensômetros lineares elétricos os quais foram colados em três faces do intermediário e nas superfícies mesial, vestibular, distal e lingual do osso simulado ao redor do implante. Os dados obtidos foram submetidos a análise de variância (ANOVA) e teste de Tukey (p<0,05). Os resultados do estudo demonstraram que a utilização dos três tipos de cilindro não alteram o resultado final de distribuição de tensão no intermediário após o carregamento. Adicionalmente as coroas confeccionadas com cilindro de CoCr usinado, tiveram o comportamento mais estável com relação a uniformidade na distribuição das tensões no intermediário e no osso simulado quando comparados com os outros dois grupos (cilindros de Au e Calcinável). / The metal-ceramic crowns implant-supported are widely used in the rehabilitation of edentulous patients. The mechanical behavior of these crowns is very important to understand the process of transmission of masticatory forces and their reactions at abutment and peri-implant bone structure, but these processes are not fully understood yet. The aim of this study was to verify the deformation in the abutment and peri-implant bone in implant-supported single crowns after load application. Was used a master model of polyurethane simulating the jawbone with an external hexagon implant of 3.75 mm of diameter and 13 mm of length, which was fixed a multi-unit abutment (Nobel Biocare, Göteborg, Sweden). The study presented three groups with four samples each, divided according to type of cylinder and casting alloy (gold cylinder smelting with the PdAg alloy, CoCr cylinder machined cast-on with the league NiCoCr, cast acrylic cylinder with alloy NiCoCr). Each sample was subjected to five times the application of vertical load of 300N on a universal testing machine. The force was applied in the center of the occlusal surface of each crown. Readings were taken of the deformations generated in the abutment and polyurethane with the use of strain gages which were glued on three sides of the abutment and mesial, buccal, lingual and distal surfaces of simulated bone around the implant. The datas were submitted to ANOVA and Tukey test (p<0.05). The study results demonstrated that the use of three types of cylinder does not change the final result of stress distribution in the intermediate after axial loading. Additionally crowns made with machined cylinder CoCr, had more stable with respect to uniform distribution of stresses in the intermediate and the simulated bone when compared with the other two groups (Au and burnout cylinders).
4

Avaliação da deformação do intermediário e região peri-implantar em função da carga aplicada em coroas unitárias implantossuportadas parafusadas / Evaluation of the deformation in the abutment and peri-implant region according to the load applied in screwed implant-supported single crowns

Max Laurent Albarracín 30 May 2011 (has links)
As coroas unitárias metalocerámicas implantossuportadas são amplamente utilizadas na reabilitação de pacientes desdentados. O comportamento mecânico destas coroas é muito importante para entender o processo de transmissão de forças mastigatórias e suas reações no intermediário e na estrutura óssea peri-implantar, mas estes processos ainda não estão totalmente compreendidos. O objetivo deste trabalho foi verificar a deformação gerada no intermediário e no osso peri-implantar de coroas unitárias implantossuportadas após aplicação de carga. Foi utilizado um modelo mestre de poliuretano, simulando o osso mandibular, com um implante hexágono externo de 3,75mm x13 mm de comprimento, no qual foi fixado um intermediário multi-unit (Nobel Biocare, Göteborg, Sweden). O trabalho apresentou 3 grupos com quatro corpos de prova cada, divididos de acordo com o tipo de cilindro e liga de fundição (Cilindro de ouro sobrefundidos com a liga de PdAg, cilindro de CoCr usinado sobrefundidos com a liga de NiCoCr, cilindro de acrílico fundido com a liga de NiCoCr ). Cada corpo de prova foi submetido cinco vezes a aplicação de carga axial de 300N em uma máquina de ensaio universal. A força foi aplicada no centro da oclusal de cada coroa. Foram realizadas leituras das deformações geradas no intermediário e no poliuretano com o uso de extensômetros lineares elétricos os quais foram colados em três faces do intermediário e nas superfícies mesial, vestibular, distal e lingual do osso simulado ao redor do implante. Os dados obtidos foram submetidos a análise de variância (ANOVA) e teste de Tukey (p<0,05). Os resultados do estudo demonstraram que a utilização dos três tipos de cilindro não alteram o resultado final de distribuição de tensão no intermediário após o carregamento. Adicionalmente as coroas confeccionadas com cilindro de CoCr usinado, tiveram o comportamento mais estável com relação a uniformidade na distribuição das tensões no intermediário e no osso simulado quando comparados com os outros dois grupos (cilindros de Au e Calcinável). / The metal-ceramic crowns implant-supported are widely used in the rehabilitation of edentulous patients. The mechanical behavior of these crowns is very important to understand the process of transmission of masticatory forces and their reactions at abutment and peri-implant bone structure, but these processes are not fully understood yet. The aim of this study was to verify the deformation in the abutment and peri-implant bone in implant-supported single crowns after load application. Was used a master model of polyurethane simulating the jawbone with an external hexagon implant of 3.75 mm of diameter and 13 mm of length, which was fixed a multi-unit abutment (Nobel Biocare, Göteborg, Sweden). The study presented three groups with four samples each, divided according to type of cylinder and casting alloy (gold cylinder smelting with the PdAg alloy, CoCr cylinder machined cast-on with the league NiCoCr, cast acrylic cylinder with alloy NiCoCr). Each sample was subjected to five times the application of vertical load of 300N on a universal testing machine. The force was applied in the center of the occlusal surface of each crown. Readings were taken of the deformations generated in the abutment and polyurethane with the use of strain gages which were glued on three sides of the abutment and mesial, buccal, lingual and distal surfaces of simulated bone around the implant. The datas were submitted to ANOVA and Tukey test (p<0.05). The study results demonstrated that the use of three types of cylinder does not change the final result of stress distribution in the intermediate after axial loading. Additionally crowns made with machined cylinder CoCr, had more stable with respect to uniform distribution of stresses in the intermediate and the simulated bone when compared with the other two groups (Au and burnout cylinders).

Page generated in 0.0971 seconds