• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • Tagged with
  • 16
  • 11
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação comparativa da validade da fórmula de Poffenberger-Swart na determinação de tensões flexurais para diferentes condutores de energia

Vilela, Thamise Sampaio Vasconcelos 22 November 2013 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Programa de Pós-Graduação em Ciências Mecânicas, 2013. / Submitted by Larissa Stefane Vieira Rodrigues (larissarodrigues@bce.unb.br) on 2014-10-23T18:38:31Z No. of bitstreams: 1 2013_ThamiseSampaioVasconcelosVilela.pdf: 3666452 bytes, checksum: 44e6e56ac06ad0872956d3dd13381091 (MD5) / Approved for entry into archive by Tania Milca Carvalho Malheiros(tania@bce.unb.br) on 2014-10-29T13:24:45Z (GMT) No. of bitstreams: 1 2013_ThamiseSampaioVasconcelosVilela.pdf: 3666452 bytes, checksum: 44e6e56ac06ad0872956d3dd13381091 (MD5) / Made available in DSpace on 2014-10-29T13:24:45Z (GMT). No. of bitstreams: 1 2013_ThamiseSampaioVasconcelosVilela.pdf: 3666452 bytes, checksum: 44e6e56ac06ad0872956d3dd13381091 (MD5) / O presente trabalho de natureza experimental, realizado por meio da utilização de extensometria, visa a validação da Fórmula de Poffenberger-Swart (P-S), aplicada extensivamente em todo o mundo para a determinação da tensão flexural nominal considerada responsável pela falha por fadiga de cabos condutores. Para efeito de comparação e determinação das limitações da expressão analítica foram realizados medições e cálculos aplicando a fórmula de P-S para seis cabos condutores com diferentes: i) materiais (alumínio, alumínio liga, alma de aço, alma de compósito); ii) geometrias (fios de seção circular ou em forma de Z); iii) configuração (com e sem alma); iv) dimensões. Os ensaios foram executados, de acordo com as recomendações da CIGRE (1985), EPRI (1979) e IEEE (1978), em uma bancada de 46,8 metros de comprimento, em ambiente climatizado, com sistema de controle dos equipamentos totalmente automatizado. Para a verificação da consistência da fórmula foram aplicadas diferentes amplitudes de flexão. A tensão nominal encontrada pela média dos extensômetros apresentou uma boa aproximação com o valor teórico obtido pela fórmula de P-S. Dois estudos adicionais compõem este trabalho: o estudo baseado na avaliação da influência da variação da carga de esticamento (variação da EDS – Every Day Stress), aplicada em cabos condutores de energia elétrica sobre a tensão média residual encontrada nos fios de alumínio da camada mais externa; e o estudo para avaliação da influência da sequência da carga de aperto dos parafusos do grampo de suspensão, que é avaliada a partir de células de carga (load washers). A carga de aperto é outro fator que influencia na vida de um condutor. ______________________________________________________________________________ ABSTRACT / The aim of this experimental work is to evaluate the effects of aeolian vibration, concerned the analysis of stress at the last point of contact of the assembly cable/suspension clamp (LPC) is an important factor to determine fretting fatigue resistance has it focus on the construction of a Wöhler curve or SN curve for a chosen cable/clamp conductors set. The LPC is the most likely point of failure. Thus, one studied in this work is the validation of Poffenberger - Swart Formula through the strain gages. Strain gages are glued on aluminum wires of the outer layer of the conductor at the point diametrically opposite to the LPC. For this purpose, the evaluation was carried out in six different cables in different displacement amplitudes YB. These cables differ in the geometry of the aluminum wire (circular or shaped Z) or the core that may be of steel, aluminum or composite . The tests were performed according to CIGRE (1985), EPRI (1979) and IEEE (1978) recommendations, in a rig fully instrumented and closed loop controlled, on a total span of 46,8 meters long, operating on a climatized environment. The nominal stress found by averaging the strain is a good approximation to the stress found by the P-S formula. The study based on the evaluation of the influence of load stretch variation (variation of EDS - Every Day Stress) applied at cable conductors of electricity, on average stress aluminum wires found in the outermost layer. Such assessment is carried out from strain gauges glued at two meters of distance from the last point of contact. Another study was to evaluate the influence of the sequence of the load screw tightening the suspension clamp, which is evaluated from load cells (load washers). The clamping load is another factor that influences the conductor life.
2

Desenvolvimento de um vibrógrafo para medir e armazenar dados de vibração de cabos de transmissão de energia elétrica / Development of measuring device for storing and vibration in electric cables

Oliveira, Murilo Cândido de 26 July 2013 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Mecânica, 2013. / Submitted by Ana Cristina Barbosa da Silva (annabds@hotmail.com) on 2014-11-20T14:43:50Z No. of bitstreams: 1 2013_MuriloCandidodeOliveira.pdf: 16383183 bytes, checksum: 000282b89676dd39d480cbb8c55a0b64 (MD5) / Approved for entry into archive by Patrícia Nunes da Silva(patricia@bce.unb.br) on 2014-11-21T11:11:03Z (GMT) No. of bitstreams: 1 2013_MuriloCandidodeOliveira.pdf: 16383183 bytes, checksum: 000282b89676dd39d480cbb8c55a0b64 (MD5) / Made available in DSpace on 2014-11-21T11:11:03Z (GMT). No. of bitstreams: 1 2013_MuriloCandidodeOliveira.pdf: 16383183 bytes, checksum: 000282b89676dd39d480cbb8c55a0b64 (MD5) / O presente trabalho consiste na concepção, fabricação e teste de um protótipo de vibrógrafo cuja função é adquirir e armazenar dados de vibração em cabos de linhas de transmissão de energia elétrica. Esses dados são essenciais para o estudo da resistência a fadiga nos cabos, o que permite ao projetista estimar a vida útil de uma determinada linha de transmissão. O vibrógrafo desenvolvido é baseado numa placa micro-controlada que gerencia um sensor de deslocamento, um conversor A/D, uma porta rs232 e um gravador SDcard. Este vibrógrafo opera de modo análogo aos equipamentos comerciais, porém armazena os dados no domínio do tempo, preservando inúmeras informações temporais, o que o diferencia dos equipamentos comerciais. O projeto mecânico do vibrógrafo contempla a realização dos métodos de medição direto e inverso, típicos para esse tipo de ensaio. ______________________________________________________________________________ ABSTRACT / This work presents consists of the design, fabrication and testing of a prototype vibrometer whose function is to acquire and store vibration data cables for transmission lines of electricity. These data are essential for the study of fatigue resistance in the cables, allowing the designer to estimate the useful life of a given transmission line. The vibrometer is developed based on a micro-plate which manages a controlled displacement sensor, an A/ D converter, an RS232 port and a recorder SDcard. This vibrógrafo operates similarly to commercial equipment, but stores the data in the time domain, preserving numerous temporal information, which differentiates it from commercial equipment. The mechanical design of the vibrometer contemplates the realization of direct measurement methods and inverse, typical for this type of test.
3

Deformações geradas no intermediário e região peri-implantar após aplicação de cargas inclinadas em coroas unitárias

Albarracín, Max Laurent 31 July 2015 (has links)
A reabilitação protética de pacientes desdentados é uma área da Odontologia amplamente estudada por pesquisadores do mundo todo, e com o desenvolvimento dos implantes osseointegrados surgiram muitas perguntas sobre o desempenho das próteses instaladas sobre estes. Conhecer o comportamento mecânico do conjunto coroa unitária, intermediário, implante e tecido de suporte é importante para entender o processo de transmissão de forças e suas consequências, processos estes que ainda não estão totalmente compreendidos. O objetivo deste trabalho foi verificar a deformação gerada no intermediário e no osso peri-implantar após aplicação de uma carga inclinada sobre coroas unitárias metalocerâmicas. Foi utilizado um modelo mestre de poliuretano, simulando o osso mandibular, com um implante hexágono externo de 3,75mm x13 mm de comprimento, no qual foi fixado um intermediário multi-unit. O trabalho foi realizado com 3 grupos de 4 coroas cada, divididos de acordo com o tipo de cilindro e liga de fundição (cilindros de ouro sobrefundidos com liga de PdAg, cilindro de acrílico fundido com liga de NiCoCr e cilindros de CoCr usinado sobrefundidos com liga de NiCoCr). Cada corpo de prova foi submetido cinco vezes à aplicação de carga oblíqua de 15 e 30 graus no centro da oclusal de cada coroa com uma força de 300N em uma máquina universal de ensaios. Foram realizadas leituras das deformações geradas no intermediário e no poliuretano, com o uso de extensômetros lineares elétricos (strain gauges) os quais foram colados em três faces do intermediário (Disto lingual, Mesio lingual, Vestibular) e nas superfícies mesial, vestibular, distal e lingual do osso simulado ao redor do implante. Os dados obtidos foram submetidos à análise de variância a 3 critérios (ANOVA) e o teste de Tukey, utilizando um nível de significância (p<0,05). Os resultados mostraram que entre as duas angulações utilizadas existiram diferenças estatísticas significantes. Os valores médios de deformação se mantiveram dentro dos padrões de normalidade, na janela fisiológica descrita por Frost entre 50 &#x3BC;&#x3B5; e 1500 &#x3BC;&#x3B5; independente do tipo de cilindro utilizado, com exceção dos valores de compressão obtidos na carga oblíqua de 30 graus onde nos três tipos de cilindro ultrapassaram a janela de sobrecarga patológica com mais de 4000 &#x3BC;&#x3B5. / The prosthetic rehabilitation of edentulous patients is a dental area widely studied by worldwide researchers, and through the development of dental implants, appear many questions about the performance of prostheses installed on them. Knowledge of the mechanical behavior of the integration between single crown, abutment, implant and support tissue is very important to understand the forces transmission process and its consequences but these processes are not fully understood. The objective of the present study was to evaluate the deformation generated in the abutment and simulated peri-implant bone after application of an oblique load on metal-ceramic crowns. A polyurethane master model was used to simulate the jawbone with an implant external hexagon 3.75 mm x13 mm length, which was fixed in a multi-unit abutment. The study was conducted with twelve metal ceramic crowns divided according to type of cylinder and casting alloy, Group 1: Gold cylinder cast with PdAg alloy; Group 2: Acrylic cylinder cast with NiCoCr alloy; Group 3: CoCr cylinder cast with NiCoCr alloy, thus forming three groups of four sample each. Each specimen was subjected five times the application of oblique load of 15 and 30 degrees in the center of the occlusal of each crown with a 300N force in a universal testing machine. Readings were taken of the deformations generated in the abutment and bone simulated by polyurethane, with the use of electric linear strain gauges which have been positioned on three sides equidistant to each other to measure microstrains at abutment (disto-lingual, meso-lingual, Vestibular) and the simulated bone around each implant received four strain gauges, positioned on the mesial, distal, buccal and lingual aspects. The data were submitted to analysis of variance to 3 criteria (ANOVA) and Tukey test, using a significance level (p <0.05). The results showed that between the two angles tested there were significant statistical differences. The deformation average values remained within normal limits, at the adapted state described by Frost between 50 &#x3BC;&#x3B5 and 1500 &#x3BC;&#x3B5 independent of the type of cylinder used, with the exception of compression values in oblique load of 30 degrees where the three types of cylinder surpassed the pathological overhead state with over 4,000 &#x3BC;&#x3B5.
4

Sistema microcontrolado para medição de forças na região plantar e nos membros superiores de pacientes

Sanches, Marcelo Augusto Assunção [UNESP] 27 April 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:31Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-04-27Bitstream added on 2014-06-13T20:08:24Z : No. of bitstreams: 1 sanches_maa_me_ilha.pdf: 1862589 bytes, checksum: e3625c1d280204f136503179cec091dd (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Este trabalho descreve um sistema eletrônico implementado com o objetivo de monitorar os esforços exercidos pelos membros superiores e inferiores de pacientes. O sistema é constituído por transdutores, circuitos de condicionamento de sinais, circuito de comunicação e um software para a aquisição de dados, além da visualização em um microcomputador. São descritos dois tipos de transdutores, construídos com extensômetros metálicos, um para conexão em muletas e o outro projetado para ser inserido em palmilhas. Os fundamentos teóricos necessários para o projeto destes transdutores são apresentados, bem como os esquemas dos circuitos implementados. É descrita a metodologia utilizada para a determinação das características estáticas e dinâmicas dos transdutores. Estes apresentaram respostas lineares, excelente repetibilidade, e faixa dinâmica que atende às finalidades do projeto. Foi desenvolvido um software com interface gráfica contendo várias telas que possibilitam diferentes análises e armazenamento de informações. Utilizando o sistema, foram realizadas, com êxito, medições de forças exercidas pelos membros inferiores e superiores de pacientes normais e hemiplégicos. / This work describes the development of a computer-based system able for monitoring forces acting on patients’ upper and lower limbs. The system consists of insoles and crutches instrumented with load cells, signal conditioning circuits, data acquisition system, and a computer. The results of the static and dynamic measurements can be presented in the screen of a computer through graphs and tables, and stored in a data base, to follow-up the development of a patient treatment. The program was developed in Visual Basic, and the communication uses the USB port. All transducers presented linear response, small hysteresis, excellent repeatability and resolution. Static and dynamic measurements performed with the transducers are presented as well as the visualization of the forces exerted on the plantar area and upper limbs of healthy and hemiplegic patients.
5

Dinamômetro biomédico para avaliação funcional das mãos

Santos, Elcio Alteris dos [UNESP] 20 February 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:31Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-02-20Bitstream added on 2014-06-13T18:07:11Z : No. of bitstreams: 1 santos_ea_me_ilha.pdf: 1369014 bytes, checksum: 7ea566c05320b595e08fe89ae2170203 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O teste de força de aperto das mãos tem como finalidade detectar eventuais patologias nos membros superiores e avaliar a força exercida pelas mãos de pacientes. Neste trabalho é descrito o desenvolvimento de um dinamômetro biomédico projetado para efetuar a avaliação funcional das mãos, através da utilização de moldes específicos. O equipamento é constituído basicamente por sensores com extensômetros metálicos, um circuito de condicionamento de sinais, um circuito de interfaceamento e por um display digital. O circuito de condicionamento de sinais foi implementado com um amplificador de instrumentação, um amplificador com ganho programável e por um filtro passa-baixas. O principal componente do circuito de interfaceamento é o microcontrolador ATMEGA8. O equipamento é robusto, apresenta resposta linear na faixa de 0 a 500 N, precisão de 0,54%, resolução de 0,70 N e histerese desprezível. O valor da força pode ser lida em um display e também na tela de um computador. Pode ser útil em Engenharia de Reabilitação, Fisioterapia e Terapia Ocupacional / In this work we describe the development of a biomedical dynamometer. It was designed with the goal of performing the functional evaluation of hands with specific shapes. The equipment is constituted by force sensors, a signal conditioning circuit, an interface circuit and a digital display. Metallic strain gages were used as sensors. The signal conditioning circuit is constituted by an instrumentation amplifier, a programmable gain amplifier and a low-pass filter. The main component of the interface circuit is an ATMEGA8 microcontroller. The instrument can measure forces with resolution of 0.70 N and precision of 0.54% in the range of 0 to 500 N. It is rugged, presents linear response and very small hysteresis. The value of the force can be read in a display and in a computer screen. The device can be useful in Rehabilitation Engineering, Physiotherapy and Ocupational Therapy
6

Estudo para desenvolvimento de um novo conceito de extensômetros impresso.

Oliveira, Antonio Wesley Carvalho de 10 January 2010 (has links)
Submitted by Alisson Mota (alisson.davidbeckam@gmail.com) on 2015-06-26T19:00:09Z No. of bitstreams: 1 Dissertação - Antonio Wesley Carvalho de Oliveira.pdf: 14382471 bytes, checksum: 51e491c08eb16a03973ecbf929d4a9e6 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-06-29T15:53:37Z (GMT) No. of bitstreams: 1 Dissertação - Antonio Wesley Carvalho de Oliveira.pdf: 14382471 bytes, checksum: 51e491c08eb16a03973ecbf929d4a9e6 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-06-29T18:06:00Z (GMT) No. of bitstreams: 1 Dissertação - Antonio Wesley Carvalho de Oliveira.pdf: 14382471 bytes, checksum: 51e491c08eb16a03973ecbf929d4a9e6 (MD5) / Made available in DSpace on 2015-06-29T18:06:00Z (GMT). No. of bitstreams: 1 Dissertação - Antonio Wesley Carvalho de Oliveira.pdf: 14382471 bytes, checksum: 51e491c08eb16a03973ecbf929d4a9e6 (MD5) Previous issue date: 2010-01-10 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The process of new product development is split-up basically in five stages: identification of opportunity and concept development, planning and product specification, development and engineering process of the product, testing and evaluations, and ram-up. The testing stage allows guaranteeing that the new product is reliable and is in accordance with customer needs. In this phase, the engineering group checks if the product is conform through experimental tools. One of these tools is the sensor generally used to measure deformation known as strain gauge. Although the strain gauges have large application, the usage of very strong quicksetting adhesive to fix the strain gauge on the body can compromise the results of the measurement. A proposal to cover the problems related to the placement of the strain gauge is to print the strain gauge on the surface of the body to be analyzed though of printing method of ink that has metal nanoparticles. The printing process consists in to deposit drops of suspension extremely thin onto the surface of a flexible polymer film. As objective, this work evaluated the performance of the printed strain gauge, obtained by silver conductive ink, above surface of flexible material. Thereunto, it was described the characteristics of the conventional strain gauge and printed strain gauge, apply the strain gauge conventional and printed on the surface of an flexible polymeric material through conventional placement methods and ink-jet print methods, compare the characteristics and measurement of strain gauge conventional and printed by mechanical tests: tensile strength and flexural, and evaluate the advantage and disadvantage of the printed strain gauge. The results obtained by the new concept of strain gauge presented very satisfactory by the experimental tests. / O processo de desenvolvimento de novos produtos dividi-se basicamente em cinco etapas: identificação de oportunidade e desenvolvimento do conceito, planejamento e especificação do produto, desenvolvimento e processo de engenharia do produto, teste e avaliação, e início da produção. A etapa de teste permite assegurar que o novo produto é confiável e está de acordo com as necessidades do cliente. Nesta etapa, a engenharia avalia se o produto está conforme por meio de ferramentas experimentais. Uma destas ferramentas é o transdutor comumente utilizado para medir deformações conhecido como extensômetro. Embora os extensômetros apresentem ampla aplicação, a utilização da cola para fixação na superfície do corpo pode comprometer os resultados de uma medição. Uma proposta para os problemas relacionados à fixação do extensômetro é imprimir o extensômetro na superfície do corpo a ser analisado por meio de impressão de tintas que utilizam nanopartículas metálicas. O processo de impressão consiste em depositar gotas de suspensão extremamente finas na superfície de um corpo flexível polimérico. Como objetivo, este trabalho avaliou a performance do extensometro impresso, obtido por meio de impressão de tinta condutiva de prata, sobre a superfície de um material flexível. Para isso, descrevem-se as características do extensometro convencional e do extensometro impresso, aplica-se o extensometro convencional e o impresso na superfície de um material polimérico flexível por meio dos métodos convencionais de fixação e impressão de nano-partículas condutivas respectivamente, comparam-se as características e medições dos extensômetros convencional e impresso por meio de ensaios mecânico: de tração e flexão, e avaliam-se as vantagens e desvantagens do extensômetro impresso. Os resultados obtidos pelo novo conceito de extensômetro apresentaram-se bastante satisfatórios nas avaliações experimentais.
7

Deformações geradas no intermediário e região peri-implantar após aplicação de cargas inclinadas em coroas unitárias

Max Laurent Albarracín 31 July 2015 (has links)
A reabilitação protética de pacientes desdentados é uma área da Odontologia amplamente estudada por pesquisadores do mundo todo, e com o desenvolvimento dos implantes osseointegrados surgiram muitas perguntas sobre o desempenho das próteses instaladas sobre estes. Conhecer o comportamento mecânico do conjunto coroa unitária, intermediário, implante e tecido de suporte é importante para entender o processo de transmissão de forças e suas consequências, processos estes que ainda não estão totalmente compreendidos. O objetivo deste trabalho foi verificar a deformação gerada no intermediário e no osso peri-implantar após aplicação de uma carga inclinada sobre coroas unitárias metalocerâmicas. Foi utilizado um modelo mestre de poliuretano, simulando o osso mandibular, com um implante hexágono externo de 3,75mm x13 mm de comprimento, no qual foi fixado um intermediário multi-unit. O trabalho foi realizado com 3 grupos de 4 coroas cada, divididos de acordo com o tipo de cilindro e liga de fundição (cilindros de ouro sobrefundidos com liga de PdAg, cilindro de acrílico fundido com liga de NiCoCr e cilindros de CoCr usinado sobrefundidos com liga de NiCoCr). Cada corpo de prova foi submetido cinco vezes à aplicação de carga oblíqua de 15 e 30 graus no centro da oclusal de cada coroa com uma força de 300N em uma máquina universal de ensaios. Foram realizadas leituras das deformações geradas no intermediário e no poliuretano, com o uso de extensômetros lineares elétricos (strain gauges) os quais foram colados em três faces do intermediário (Disto lingual, Mesio lingual, Vestibular) e nas superfícies mesial, vestibular, distal e lingual do osso simulado ao redor do implante. Os dados obtidos foram submetidos à análise de variância a 3 critérios (ANOVA) e o teste de Tukey, utilizando um nível de significância (p<0,05). Os resultados mostraram que entre as duas angulações utilizadas existiram diferenças estatísticas significantes. Os valores médios de deformação se mantiveram dentro dos padrões de normalidade, na janela fisiológica descrita por Frost entre 50 &#x3BC;&#x3B5; e 1500 &#x3BC;&#x3B5; independente do tipo de cilindro utilizado, com exceção dos valores de compressão obtidos na carga oblíqua de 30 graus onde nos três tipos de cilindro ultrapassaram a janela de sobrecarga patológica com mais de 4000 &#x3BC;&#x3B5. / The prosthetic rehabilitation of edentulous patients is a dental area widely studied by worldwide researchers, and through the development of dental implants, appear many questions about the performance of prostheses installed on them. Knowledge of the mechanical behavior of the integration between single crown, abutment, implant and support tissue is very important to understand the forces transmission process and its consequences but these processes are not fully understood. The objective of the present study was to evaluate the deformation generated in the abutment and simulated peri-implant bone after application of an oblique load on metal-ceramic crowns. A polyurethane master model was used to simulate the jawbone with an implant external hexagon 3.75 mm x13 mm length, which was fixed in a multi-unit abutment. The study was conducted with twelve metal ceramic crowns divided according to type of cylinder and casting alloy, Group 1: Gold cylinder cast with PdAg alloy; Group 2: Acrylic cylinder cast with NiCoCr alloy; Group 3: CoCr cylinder cast with NiCoCr alloy, thus forming three groups of four sample each. Each specimen was subjected five times the application of oblique load of 15 and 30 degrees in the center of the occlusal of each crown with a 300N force in a universal testing machine. Readings were taken of the deformations generated in the abutment and bone simulated by polyurethane, with the use of electric linear strain gauges which have been positioned on three sides equidistant to each other to measure microstrains at abutment (disto-lingual, meso-lingual, Vestibular) and the simulated bone around each implant received four strain gauges, positioned on the mesial, distal, buccal and lingual aspects. The data were submitted to analysis of variance to 3 criteria (ANOVA) and Tukey test, using a significance level (p <0.05). The results showed that between the two angles tested there were significant statistical differences. The deformation average values remained within normal limits, at the adapted state described by Frost between 50 &#x3BC;&#x3B5 and 1500 &#x3BC;&#x3B5 independent of the type of cylinder used, with the exception of compression values in oblique load of 30 degrees where the three types of cylinder surpassed the pathological overhead state with over 4,000 &#x3BC;&#x3B5.
8

Avaliação da deformação do intermediário e região peri-implantar em função da carga aplicada em coroas unitárias implantossuportadas parafusadas / Evaluation of the deformation in the abutment and peri-implant region according to the load applied in screwed implant-supported single crowns

Albarracín, Max Laurent 30 May 2011 (has links)
As coroas unitárias metalocerámicas implantossuportadas são amplamente utilizadas na reabilitação de pacientes desdentados. O comportamento mecânico destas coroas é muito importante para entender o processo de transmissão de forças mastigatórias e suas reações no intermediário e na estrutura óssea peri-implantar, mas estes processos ainda não estão totalmente compreendidos. O objetivo deste trabalho foi verificar a deformação gerada no intermediário e no osso peri-implantar de coroas unitárias implantossuportadas após aplicação de carga. Foi utilizado um modelo mestre de poliuretano, simulando o osso mandibular, com um implante hexágono externo de 3,75mm x13 mm de comprimento, no qual foi fixado um intermediário multi-unit (Nobel Biocare, Göteborg, Sweden). O trabalho apresentou 3 grupos com quatro corpos de prova cada, divididos de acordo com o tipo de cilindro e liga de fundição (Cilindro de ouro sobrefundidos com a liga de PdAg, cilindro de CoCr usinado sobrefundidos com a liga de NiCoCr, cilindro de acrílico fundido com a liga de NiCoCr ). Cada corpo de prova foi submetido cinco vezes a aplicação de carga axial de 300N em uma máquina de ensaio universal. A força foi aplicada no centro da oclusal de cada coroa. Foram realizadas leituras das deformações geradas no intermediário e no poliuretano com o uso de extensômetros lineares elétricos os quais foram colados em três faces do intermediário e nas superfícies mesial, vestibular, distal e lingual do osso simulado ao redor do implante. Os dados obtidos foram submetidos a análise de variância (ANOVA) e teste de Tukey (p<0,05). Os resultados do estudo demonstraram que a utilização dos três tipos de cilindro não alteram o resultado final de distribuição de tensão no intermediário após o carregamento. Adicionalmente as coroas confeccionadas com cilindro de CoCr usinado, tiveram o comportamento mais estável com relação a uniformidade na distribuição das tensões no intermediário e no osso simulado quando comparados com os outros dois grupos (cilindros de Au e Calcinável). / The metal-ceramic crowns implant-supported are widely used in the rehabilitation of edentulous patients. The mechanical behavior of these crowns is very important to understand the process of transmission of masticatory forces and their reactions at abutment and peri-implant bone structure, but these processes are not fully understood yet. The aim of this study was to verify the deformation in the abutment and peri-implant bone in implant-supported single crowns after load application. Was used a master model of polyurethane simulating the jawbone with an external hexagon implant of 3.75 mm of diameter and 13 mm of length, which was fixed a multi-unit abutment (Nobel Biocare, Göteborg, Sweden). The study presented three groups with four samples each, divided according to type of cylinder and casting alloy (gold cylinder smelting with the PdAg alloy, CoCr cylinder machined cast-on with the league NiCoCr, cast acrylic cylinder with alloy NiCoCr). Each sample was subjected to five times the application of vertical load of 300N on a universal testing machine. The force was applied in the center of the occlusal surface of each crown. Readings were taken of the deformations generated in the abutment and polyurethane with the use of strain gages which were glued on three sides of the abutment and mesial, buccal, lingual and distal surfaces of simulated bone around the implant. The datas were submitted to ANOVA and Tukey test (p<0.05). The study results demonstrated that the use of three types of cylinder does not change the final result of stress distribution in the intermediate after axial loading. Additionally crowns made with machined cylinder CoCr, had more stable with respect to uniform distribution of stresses in the intermediate and the simulated bone when compared with the other two groups (Au and burnout cylinders).
9

Utilização de extensômetro para monitoramento contínuo da tensão do detrusor. Estudo experimental em coelhos / Use of strain gauge for continuous detrusor tension monitoring. Experimental study in rabbits

Ferreira, Wilson Seluque 20 May 2016 (has links)
Introdução: O ato da micção é processo complexo que envolve o encéfalo, a medula espinhal, o sistema nervoso periférico e a integridade neuromuscular do trato urinário baixo. Essa integridade permite a ocorrência da fase de armazenamento de urina na bexiga e, a seguir, da fase de esvaziamento vesical. Havendo comprometimento das conexões entre esses componentes, tanto o enchimento quanto o esvaziamento vesical podem estar comprometidos. Conhecendo as propriedades do extensômetro elétrico de resistência, foi proposta a construção de um aparato com capacidade de avaliar a condição de enchimento vesical e que permita a correlação direta com a pressão intravesical. Objetivo: Desenvolver e demonstrar o funcionamento de um equipamento para monitoramento contínuo da tensão do detrusor, em coelhos, durante a fase de enchimento vesical. Material e Métodos: Foram utilizadas 12 coelhas da raça Nova Zelândia. Após anestesia, a bexiga foi exposta por incisão mediana e a uretra foi obstruída com ligadura por fio de algodão. O sensor de tensão foi suturado ao detrusor e confeccionada cistostomia por punção com Abocath 16, utilizada para enchimento e esvaziamento vesical e cistometria, avaliada pelo equipamento Dynamed® - modelo Dynapack MPX-B16. Os coelhos foram submetidos ao procedimento de monitorização inicial (enchimento vesical monitorado pela cistometria) e a medida da tensão da parede vesical - com a bexiga totalmente preservada. Resultados: No decorrer dos experimentos e com a conclusão das análises estatísticas, encontramos uma correlação muito importante entre os dados. Quando se coloca em foco apenas um animal, verifica-se uma grande correlação entre os dados provenientes do volume infundido na bexiga em função da curva gerada para a pressão intravesical que, por sua vez, acompanha fidedignamente a curva da tensão lida na parede vesical do mesmo animal. Quando avaliados conjuntamente, verificasse que os dados são muito próximos uns dos outros, tais como o volume infundido e a tensão final em mV, lida pelo equipamento desenvolvido. Conclusão: O equipamento foi desenvolvido e, com base nos resultados obtidos, mostrou-se adequado para o monitoramento contínuo da tensão vesical do detrusor e sua correlação com o volume vesical, em coelhos, durante a fase de enchimento vesical. / Introduction: Urination is a complex process which involves the brain, the spinal cord, the peripheral nervous system and the neuromuscular integrity of the lower urinary tract. It is the unimpaired condition of all those parts that allows the bladder to go through its functional states - storage phase (filling) and voiding phase (emptying). Problems within these anatomical structures connections can also compromise both phases. This thesis presents the design of a new device which uses an electrical resistance strain gauge to evaluate the bladder\'s filling and its direct correlation with the intravesical pressure. Objective: To develop and demonstrate the operation of a new device that checks continuously rabbit\'s detrusor pressure during bladder filling. Material and Methods: 12 rabbits of New Zealand race were used. After anesthesia, their bladders and urethras were exposed via an abdominal incision made at the midline. Then, the urethra obstruction was performed by ligation using cotton thread. The tension sensor was sutured to the detrusor and a cystostomy puncture was made with an Abocath 16. The puncture was used for filling and voiding cystometry using the urodynamic equipment, Dynamed - Dynapack model MPX-B16. Data collected by this equipment was used as the baseline. Rabbits underwent an initial monitoring procedure, bladder\'s filling cystometry using the Dynamed equipment, and voltage measurement of the bladder wall using the new device - bladder integrity was preserved. Results: During the experimental phase, completion of the statistical analyzes showed us a very significant data correlation. Correlation was stronger when evaluating each animal data individually. The infused volume in the bladder, which was verified by the intravesical pressure curve, and the voltage measured on the bladder wall faithfully followed each other. When evaluating the combined data of all rabbits, correlation was less but still significant. Volume and voltage curves still resembled one another, especially the infused volume with the final voltage reading, in mV. Conclusion - Based on the results of the experimental phase in animals, the developed device is adequate for continuous detrusor pressure monitoring and its correlation with the bladder volume in the storage phase.
10

Desenvolvimento de um sistema minimamente invasivo para monitorar a pressão intracraniana / Development of a minimally invasive system to monitor the intracranial pressure

Vilela, Gustavo Henrique Frigieri 02 December 2010 (has links)
A pressão intracraniana (PIC) é um dos principais parâmetros neurológicos em animais e humanos. A PIC é uma função da relação entre o conteúdo da caixa craniana (parênquima cerebral, líquido cefalorraquiano e sangue) e o volume do crânio. O aumento da PIC (hipertensão intracraniana) pode acarretar graves efeitos fisiológicos ou até mesmo o óbito em pacientes que não receberem rapidamente os devidos cuidados, os quais incluem o monitoramento em tempo real da PIC. Todos os métodos de monitoramento da PIC atualmente utilizados são invasivos, ou seja, é necessário introduzir um sensor de pressão no sistema nervoso central, acarretando aos pacientes riscos de infecções e traumas decorrentes do método. Neste trabalho desenvolvemos um método minimamente invasivo de monitoramento da pressão intracraniana, que consiste na utilização de sensores de deformação do tipo strain gauge fixados sobre a calota craniana. Os sinais oriundos deste sensor foram amplificados, filtrados e enviados para um computador com software apropriado para análise e armazenamento dos dados. O trabalho aqui apresentado objetivou os testes &quot;in vivo&quot; do sistema, onde foi utilizada mais de uma centena de animais em diversos testes, sendo que em todos os casos os resultados foram satisfatórios, apontando a eficácia do método. / The intracranial pressure (ICP) is one of the most important neurological parameter in animals and humans. The ICP is a function of the relation between the contents of the skull (brain parenchyma, cerebrospinal fluid and blood) and the volume of the skull. The increase in ICP (intracranial hypertension) may cause serious physiological effects and death in patients that do not receive appropriate care quickly, which includes real-time monitoring of ICP. All monitoring methods currently used in ICP are invasive, ie requiring invasion of the central nervous system by a pressure sensor, causing infections and traumas risks to patients. In this work we present a new minimally invasive method to monitor the intracranial pressure. This uses strain gauge deformation sensors, externally glued on the skull. The signal from this sensor is amplified, filtered and sent to a computer with appropriate software for analysis and data storage. &quot;In vitro&quot; and &quot;in vivo&quot; experiments let to the following results: (1) Our minimally invasive system is capable of adequately monitoring the ICP. (2) The measurements are in real and online time providing excellent signal and stability. (3) Simultaneous comparison with invasive methods not only validated our results but showed increased performance. The equipment cost effective will allow the use of our system in the Public Health System, with a important social aspect of our contribution.

Page generated in 0.4602 seconds