• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • Tagged with
  • 7
  • 7
  • 7
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Diagnóstico de corrosividade em eletrodo de aterramento elétrico cobreado

Nascimento, Cleberson Lopes do 13 September 2013 (has links)
Resumo: A confiabilidade de um sistema elétrico e a segurança da vida das pessoas depende do perfeito funcionamento do aterramento elétrico e de seus materiais empregados. Neste contexto a durabilidade de um eletrodo de aterramento cobreado consiste no tempo que decorre da sua instalação propriamente dita no solo até à instalação de processos de corrosividade em sua camada de recobrimento que irá proporcionar a descontinuidade elétrica e o consequente aumento da resistência ôhmica de aterramento. Como os eletrodos de aterramento encontram-se diretamente em contato com o solo, com a ação da água e / ou de outros contaminantes, eles sempre operam em condições de corrosão. Visto a dificuldade para a visualização do estado físico dos eletrodos de aterramento por encontrarem-se enterrados o presente trabalho aborda a análise experimental para concepção de sensoriamento eletroquímico com o objetivo de diagnóstico de corrosão / formação de óxido instalado sobre a superfície de um eletrodo de aterramento cobreado. Com este intuito foi desenvolvida uma metodologia para diagnóstico da corrosividade através do estudo em uma célula eletroquímica composta de três eletrodos e com a utilização de técnicas eletroquímicas caracterizou-se os parâmetros elétricos do eletrodo de cobre em estados de superfícies distintas: polido e oxidado.
2

Análise eletrodinâmica em estruturas de aterramento usando o método FDTD

Barberini, Sinésio Julio January 2005 (has links)
Orientador: Wilson Arnaldo Artuzi Junior / Dissertaçao (mestrado) - Universidade Federal do Paraná, Setor de Tecnologia, Programa de Pós-Graduaçao em Engenharia Elétrica. Defesa: Curitiba, 2005 / Inclui bibliografia e anexos / Resumo: O objetivo deste trabalho é realizar a simulação de transientes em estruturas de aterramento industrial. As grandezas avaliadas nas simulações são as distribuições dos campos elétricos em pontos diversos das estruturas. Com estes valores de campo, são obtidos os valores de potencial no domínio do tempo. Inicialmente são avaliados potenciais no domínio do tempo para eletrodos verticais excitados por uma forma de onda padrão do tipo dupla exponencial para validação, comparando com os resultados experimentais apresentados na literatura. Posteriormente são analisados eletrodos horizontais. Uma vez obtidos os potenciais, são determinadas as impedâncias de terra destes eletrodos para diversas características de solo. Como última parte do trabalho, é obtido o perfil do campo elétrico na interface ar-solo de uma malha de aterramento real em valores específicos de freqüência. A ferramenta utilizada é o método FDTD (Diferenças Finitas no Domínio do Tempo). Palavras-chave: Impedância de terra, aterramento, FDTD. / Abstract: The purpose of this work is to carry through transient simulation in industrial grounding structures. The parameters evaluated in the simulations are the electric fields distributions in various places of the structures. With these values, time domain potential are gotten. In the beginning, time domain potential are evaluated for vertical electrodes excited by a standard double exponetial wave form to validate by comparing the results with the experimental tests presented in the literature. Later, horizontal electrodes are analyzed. Having the potentials, the grounding impedances of these electrodes, for various soils characteristics, are determined. Finally, the electric field profile in the ground-air interface of a real ground grid is gotten in specific values of frequency . The analysis is with the FDTD (Finite Differences - Time Domain) method. Keywords: Grounding impedande, grounding, FDTD.
3

Sistema de aterramento com cabo contrapeso representado por linhas de transmissão implementado em Matlab com circuitos em cascatas de PÍ /

Spozito Junior, José Saverio. January 2012 (has links)
Orientador: Luiz Fernando Bovolato / Banca: Sérgio Kurokawa / Banca: Rodrigo Capobianco Guido / Resumo: Este estudo é um levantamento de artigos e publicações sobre os diversos sistemas de aterramento existentes. Os sistemas de aterramento estão diretamente ligados à proteção das instalações de subestações e equipamentos empregados na geração, transmissão e distribuição de energia elétrica que por ocasião das descargas atmosféricas diretas ou por tensões induzidas por campos eletromagnéticos decorrentes, possam ser prejudicados. O Método propõe o estudo de um sistema de aterramento, com cabo contrapeso, utilizando abordagem por linhas de transmissão representada por uma cascata de circuitos π, analisado e simulado pelo "Software Matlab". Utilizou-se a simulação com o emprego de programa no Matlab para linhas de transmissão de energia elétrica, a primeira com comprimento de dez mil metros e outra com oitenta metros, utilizada como referencial na comparação das respostas aos sinais de entrada aplicados nos circuitos π simulando o cabo contrapeso com seus componentes representado pelos parâmetros elétricos. Através de variação no parâmetro resistividade do solo comparou-se os resultados mostrados nos gráficos da tensão elétrica na terminação do cabo contrapeso, simulado como uma linha de transmissão com terminação em aberto. Como analise adicional em termos de segurança foi implementado no programa a analise das tensões elétricas ao longo do cabo contrapeso, excitado por aplicação de sinais de tensão elétrica e de corrente elétrica estabelecendo a comparação entre os potenciais elétricos sobre o solo em valores máximos que podem afetar seres vivos / Abstract: This study is a survey of articles and publications on the various existing grounding systems. The grounding systems are directly linked to the protection of substation facilities and equipment used in the generation, transmission and distribution of electric power, due to induced voltages by lightning's generating electromagnetic fields . The method proposed in this study, about a grounding system made with a buried cable using the approach by transmission lines method, represented by a cascade of π circuits analyzed and simulated by Matlab Software. The simulation with the Matlab program on transmission lines of electricity, one ten thousand meters in length and another eighty meters respectively, to serve as a reference in comparison between responses to input signals applied to the cable simulated by π circuit employing the parameters involved. Through variation in the soil resistivity parameter, the results are shown in the graphs of voltage in the termination of the grounding cable, simulated as an open line at end. As further analysis in terms of safety, was implemented the analysis of the voltages along the cable, by applying voltage signals and current to check the electrical potentials on the ground, the maximum values that affect persons / Mestre
4

Medição de malha de terra em subestações energizadas /

Beltani, Juliano Munhoz. January 2007 (has links)
Orientador: Luiz Fernando Bovolato / Banca: José Carlos Rossi / Banca: Edilson de Andrade Barbosa / Resumo: Os sistemas de aterramento de subestações exigem uma avaliação permanente devido não só ao envelhecimento das malhas de terra, problemas de corrosão, ocorrência de vandalismo, assim como à ação de pessoas qualificadas ou não. Como as condições de se desligar a energia de uma subestação ficaram cada vez mais difíceis de acontecer, cresceu a necessidade de se buscarem alternativas de medições viáveis, dando-se preferência aos métodos de medição de subestação energizada. Esporadicamente, uma ou outra empresa busca desenvolver técnicas de medições com as instalações energizadas, deparando-se, porém, com obstáculos que comprometem a qualidade dos resultados de ensaios, quais sejam as interferências eletromagnéticas nos instrumentos utilizados e, conseqüentemente, nas leituras realizadas, exposição a riscos (segurança pessoal e aparelhos utilizados), bem como os longos períodos tomados na execução dos ensaios. Este trabalho tem como objetivo a validação de um método existente, por meio de estudos de casos, a qual propicia uma rápida avaliação da malha de forma segura, sem prejudicar tanto a qualidade quanto a continuidade do fornecimento de energia. Esta proposta de validação é baseada... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The energy substation embankment systems require a permanent assessment due to not only the aging of the land meshes, corrosion problems and vandalism occurrences, but also for the actions of people, being qualified or not. Since the conditions to turn an energy substation off are more and more difficult to cause intentionally for maintenance reasons, a need for practicable measurement alternatives has increased, preferably the methods of measuring energized substations. From time to time a company tries to develop some measurement technique with the installations energized, however it confronts with some various constraints that may be risky for the quality of the test results, such as the electromagnetic interferences in the tools being used, consequently in the readings obtained; exposure to risks (personal safety and devices being used) as well as the fact of a testing accomplishment takes some long periods of time. This work aims, by means of studying some cases, to get some validation for an existing method which provides a rapid assessment of the land meshes in a safety way, with no harmful consequences for both the quality and the continuity of the energy supplying. The validation proposed is based on the procedures used in... (Complete abstract click electronic access below) / Mestre
5

Estudo do aterramento dos pés de torres de linha de transmissão frente às descargas atmosféricas

Berardo, Benício Luiz [UNESP] 03 February 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:34Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-02-03Bitstream added on 2014-06-13T20:08:31Z : No. of bitstreams: 1 berardo_bl_me_bauru.pdf: 467989 bytes, checksum: 1b7cb5967b4080092b9a0c9ae7a58c49 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho mostra o estudo de uma linha de transmissão onde ocorreram desligamentos causados por descargas atmosféricas. Esse estudo foi feito a partir de informações de desligamentos de linhas de transmissão da concessionária e dados extraídos de um sistema de análise e monitoramento de descargas atmosféricas. Para esse trecho da linha de transmissão foram identificadas incidências de descargas atmosféricas que causaram desligamentos, bem como descargas que não causaram desligamentos. Baseados nestas informações foram efetuadas medições em campo de resistência de aterramento dos contrapesos e da resistividade do solo, onde foi possível constatar através dos resultados que algumas torres apresentaram valores que ultrapassaram os valores normatizados. O levantamento dessas informações é o principal foco deste estudo, que visa fornecer subsídios para a identificação de torres problemáticas. Uma proposta clássica utilizada para melhorar o desempenho desta linha de transmissão frente à incidência de descargas atmosféricas foi testada mas seu resultado não foi muito satisfatário / This paper shows the study of a transmission line where outages occurred because of lightnings. The study was made from information that came from the power utility transmission line disconnection and data obtained from lightnings analyses and monitoring system. For this part of the transmission line it was identified incidence of lightning that caused outages, as well as incidences that did not cause outages. Based on this information, it was performed field measurements of ground resistance counterpoise and resistivity where is was possible to find, trough the results that some of the towers present numbers trepassed the normal values. Coming up with this information is this information is the main goal of this study that aims to offer to identify the towers that contains problems. A classical proposal used to improve the performance of this transmission line facing the incidence of lightnings was tested but the result wasn't very satisfactory
6

Medição de malha de terra em subestações energizadas

Beltani, Juliano Munhoz [UNESP] 02 February 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:36Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-02-02Bitstream added on 2014-06-13T19:08:15Z : No. of bitstreams: 1 beltani_jm_me_ilha.pdf: 770313 bytes, checksum: c4aedd3b82cf36c970644fabd877c0a8 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os sistemas de aterramento de subestações exigem uma avaliação permanente devido não só ao envelhecimento das malhas de terra, problemas de corrosão, ocorrência de vandalismo, assim como à ação de pessoas qualificadas ou não. Como as condições de se desligar a energia de uma subestação ficaram cada vez mais difíceis de acontecer, cresceu a necessidade de se buscarem alternativas de medições viáveis, dando-se preferência aos métodos de medição de subestação energizada. Esporadicamente, uma ou outra empresa busca desenvolver técnicas de medições com as instalações energizadas, deparando-se, porém, com obstáculos que comprometem a qualidade dos resultados de ensaios, quais sejam as interferências eletromagnéticas nos instrumentos utilizados e, conseqüentemente, nas leituras realizadas, exposição a riscos (segurança pessoal e aparelhos utilizados), bem como os longos períodos tomados na execução dos ensaios. Este trabalho tem como objetivo a validação de um método existente, por meio de estudos de casos, a qual propicia uma rápida avaliação da malha de forma segura, sem prejudicar tanto a qualidade quanto a continuidade do fornecimento de energia. Esta proposta de validação é baseada... / The energy substation embankment systems require a permanent assessment due to not only the aging of the land meshes, corrosion problems and vandalism occurrences, but also for the actions of people, being qualified or not. Since the conditions to turn an energy substation off are more and more difficult to cause intentionally for maintenance reasons, a need for practicable measurement alternatives has increased, preferably the methods of measuring energized substations. From time to time a company tries to develop some measurement technique with the installations energized, however it confronts with some various constraints that may be risky for the quality of the test results, such as the electromagnetic interferences in the tools being used, consequently in the readings obtained; exposure to risks (personal safety and devices being used) as well as the fact of a testing accomplishment takes some long periods of time. This work aims, by means of studying some cases, to get some validation for an existing method which provides a rapid assessment of the land meshes in a safety way, with no harmful consequences for both the quality and the continuity of the energy supplying. The validation proposed is based on the procedures used in... (Complete abstract click electronic access below)
7

Estudo do aterramento dos pés de torres de linha de transmissão frente às descargas atmosféricas /

Berardo, Benício Luiz. January 2012 (has links)
Orientador: André Christóvão Pio Martins / Coorientador: André Nunes de Souza / Banca: Oscar Armando Maldonado Astorga / Banca: Pedro da Costa Junior / Resumo: Este trabalho mostra o estudo de uma linha de transmissão onde ocorreram desligamentos causados por descargas atmosféricas. Esse estudo foi feito a partir de informações de desligamentos de linhas de transmissão da concessionária e dados extraídos de um sistema de análise e monitoramento de descargas atmosféricas. Para esse trecho da linha de transmissão foram identificadas incidências de descargas atmosféricas que causaram desligamentos, bem como descargas que não causaram desligamentos. Baseados nestas informações foram efetuadas medições em campo de resistência de aterramento dos contrapesos e da resistividade do solo, onde foi possível constatar através dos resultados que algumas torres apresentaram valores que ultrapassaram os valores normatizados. O levantamento dessas informações é o principal foco deste estudo, que visa fornecer subsídios para a identificação de torres problemáticas. Uma proposta clássica utilizada para melhorar o desempenho desta linha de transmissão frente à incidência de descargas atmosféricas foi testada mas seu resultado não foi muito satisfatário / Abstract: This paper shows the study of a transmission line where outages occurred because of lightnings. The study was made from information that came from the power utility transmission line disconnection and data obtained from lightnings analyses and monitoring system. For this part of the transmission line it was identified incidence of lightning that caused outages, as well as incidences that did not cause outages. Based on this information, it was performed field measurements of ground resistance counterpoise and resistivity where is was possible to find, trough the results that some of the towers present numbers trepassed the normal values. Coming up with this information is this information is the main goal of this study that aims to offer to identify the towers that contains problems. A classical proposal used to improve the performance of this transmission line facing the incidence of lightnings was tested but the result wasn't very satisfactory / Mestre

Page generated in 0.1088 seconds