• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • 2
  • Tagged with
  • 25
  • 25
  • 9
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estimation of electrochemical noise impedance and corrosion rates from electrochemical noise measurements.

Lowe, Alexander M. January 2002 (has links)
Electrochemical noise refers to the spontaneous fluctuations in potential and current that can be observed on a corroding metal. The use of electrochemical noise for obtaining information on the corrosion process generates much interest in research fields. One important application is the measurement of corrosion rate. This can be achieved using the electrochemical noise of a pair of electrically coupled corroding metals to obtain an estimate of electrochemical impedance - an abstract quantity that reflects various aspects of the corrosion process.There are a number of problems associated with estimation of impedance information from the electrochemical noise data, particularly regarding data pre-treatment, accuracy and precision. In addition, the present methods are incomplete: current literature does not offer information regarding the phase of the impedance; and assumptions regarding symmetry of an electrode pair cannot be tested without additional measurements.The thesis addresses the above mentioned problems. Specifically,analysis of the impedance estimation process is given to determine how precision can be affected by various factors;a novel signal processing technique is described that is shown to yield a local optimum precision;the application of the proposed signal processing to time varying systems is demonstrated by use of a time varying, frequency dependent impedance estimate;a technique for recovering phase information, given certain conditions, is suggested so that Nyquist impedance diagrams can be constructed; anda technique for testing the symmetry of a coupled pair of corroding metals is described.An integral part of electrochemical noise analysis is the software used for numerical computation. The Matlab package from MathWorks inc. provides an extensible platform for electrochemical noise analysis. Matlab code is provided in Appendix A to implement ++ / much of the theory discussed in the thesis.Impedance analysis and many other electrochemical corrosion monitoring techniques are primarily used for uniform corrosion, where the corrosion patterns occur uniformly over the exposed surface. In order to map localised corrosion, where the corrosion is typically concentrated within a small area, a wire beam electrode can be used. A wire beam electrode is a surface that is divided into a matrix of mini-electrodes so that the corrosion rate at different points can be monitored. However, manual connection of each mini-electrode to the measurement device can prove cumbersome. The final chapter of this thesis describes the design and testing of specialised multiplexing hardware to automate the process.In general, the thesis shows that by careful conditioning of the electrochemical noise prior to analysis, many of the problems with the technique of impedance estimation from the electrochemical noise data can be overcome. It is shown that the electrochemical noise impedance estimation can be extended to encompass a time varying, frequency dependent quantity for studying dynamic systems; that phase information can be recovered from electrochemical noise for the purpose of constructing Nyquist impedance diagrams; and that asymmetric electrodes can be detected without requiring additional measurements.
2

Effect of Localized Corrosion of Steel on Chloride-Induced Concrete Cover Cracking in Reinforced Concrete Structures

Busba, Ezeddin Rafaa 01 January 2013 (has links)
Abstract: Concrete cover cracking due to reinforcement corrosion is widely accepted as a limit-state indicator in defining the end of functional service life for existing reinforced concrete (RC) structures undergoing corrosion. Many of the currently available durability prediction models are incapable of providing realistic estimates of remaining service lives of RC structures beyond the corrosion initiation point. Therefore, the need to incorporate the length of the corrosion propagation stage in a comprehensive durability prediction approach has recently received much research attention. Previous research focus however was mostly limited to the case of uniformly corroding reinforcement with only few studies addressing the commonly encountered case of localized rebar corrosion. It was empirically shown in a previous study that localized corrosion can have a mitigating effect on time to concrete cover cracking due to the larger required depth of rebar corrosion penetration (Critical penetration or Xcrit). The present research was focused on developing a model for predicting Xcrit for various degrees of corrosion localization including new cases of highly localized corrosion. Accelerated corrosion testing of controlled anodic regions along axial rebars in sound concrete cylinders suggested that localized corrosion can increase Xcrit by up to about a factor of 10. The effect of corrosion localization on the orientation of corrosion-induced surface cracks was also addressed. Testing of freely corroding pre-cracked RC pipe specimens in a chloride-containing environment indicated that steel corrosion can be localized at intersection regions with the pre-existing cracks and uniformly distributed around the reinforcing steel perimeter. Numerical modeling was undertaken to substantiate the experimentally observed trends on a theoretical basis for various degrees of corrosion localization. A mechanical model was developed to improve understanding of the underlying mechanism responsible for corrosion-induced stresses. A thick-walled multiple-cylinder approach was employed to simulate crack initiation and propagation to account for the residual strength property of concrete after cracking by applying the principles of applied elasticity. For a given concrete cover depth, the amount of Xcrit was shown by modeling to be largely determined by the length of corroding region and the capacity of the induced cracks to accommodate produced rusts. The properties of both concrete-rebar interface and corrosion products were also found to have a significant impact on Xcrit. Based on the model and experimental trends and comparisons with literature data, an improved relationship for the estimation of Xcrit was proposed. An electrochemical model was also formulated to address the possible role of corrosion aggravation due to macrocell coupling in counteracting the mitigating effect of increased Xcrit on time to concrete cover cracking. Findings confirmed that corrosion localization can reasonably be considered a mitigating factor for extending the corrosion propagation stage, and provided more precise quantification to that effect.
3

Experimental study of corrosion rate and slug flow characteristics in horizontal, multiphase pipeline

Zhou, Xianling January 1993 (has links)
No description available.
4

Effects of ozonation on cooling water systems

Mosugelo, Keneetswe Lilian 26 July 2010 (has links)
Cooling water systems are needed to dissipate heat. The mist from open system cooling towers has been implicated as a source of infections of Legionella pneumophila. As a result biocide is added to cooling water systems, but the addition of biocide worsens biofouling, scaling and corrosion. Increasing environmental pressure has resulted in a move away from biocides which are usually chlorine based chemicals, so that the use of ozone instead has recently been reported as a way of controlling microbiological growth. This study aims to compare the corrosion rates (using calculated and measured surface areas) of different metals exposed to chemically treated and ozone treated cooling water in an industrial cooling water system. The types of corrosion were also observed and recorded. The scales from different components of the cooling systems as well as scale from chemically and ozone treated D tower water were characterized qualitatively using X-ray diffraction (XRD), Thermo gravimetric Analysis (TGA) and Atomic Absorption Spectroscopy. The D tower is a cooling water circuit in which the cooling water is from the Vaal River. As expected, the stainless steel has the lowest corrosion rate of 0.000 milli inches/year followed by brass with 1.531 milli inches/year and lastly mild steel (2.098 milli inches/year). Water quality rather than the presence or absence of ozone determines the corrosion rate. This confirms the findings reported in the literature. Scale from chemically treated water contains many different compounds while scale from ozone treated contains only different polymorphs of CaCO3, which is present in the water source and magnesium calcite.
5

Corrosion Dynamics of Cobalt-Chromium Alloy F-75 Powder

Tong, Tedman 01 August 2010 (has links)
The increasing usage of metal-on-metal joint replacements consisting of a cobalt-chromium-molybdenum alloy requires increasing concern regarding the inevitable generation of metallic wear debris. Patients with these joint replacements exhibit elevated concentrations of cobalt and chromium ions within their serum, blood and urine. The presence of these metal ions suggests the potential for bodily damage and indicates corrosive processes are acting upon wear debris. To understand the behavior of these corrosive processes, powders of cobalt-chromium-molybdenum alloy F-75 were studied. Four powder sizes (44, 74, 105, and 420 µm diameter) were subjected to Hank’s Balanced Salt Solution (HBSS) for a 42 day immersion test within an incubating shaker set at 37°C. Samples were removed periodically and analyzed for cobalt and chromium content using Inductive Coupled Plasma – Optical Emission Spectroscopy (ICP-OES). The resulting data gathered allowed for an evaluation of the corrosion rate as a function of particle diameter and exposure duration. Two observations were noted from the results. First, cobalt concentration (no chromium was detected) increased as a logarithmic function of time. For the 44, 105, and 420 µm diameter powders, cobalt concentration increased rapidly within four days of exposure but corrosion reached a plateau afterwards. The development of an oxide layer that inhibited further corrosion was the cause for this behavior. Second, the cobalt concentration reached a different upper limit depending on the particle diameter. For the 44, 105, and 420 µm diameter powders, samples reached average limits of 0.0611, 0.0314, and 0.0291 ppm Co, respectively. This observation can be related to the increase in particle surface area as diameter decreases within a given volume of particles. Modeling of this data resulted in empirical relationships for cobalt concentration and corrosion rate as a function of time, and particle diameter or surface area. However, these relationships were not reliably accurate in predicting the results of external corrosion studies on submicron cobalt-chromium particles. Consequently, this model of particle corrosion does not predict what may occur with nano-scale particles.
6

Application of Statistical Methodology on Monitoring the Failure Conditions of Static Equipments in the Petroleum Process

Chen, Chun-hung 13 December 2008 (has links)
In overwhelming majority of the petroleum or petrochemical plants, pressure vessels and process piping play important roles among the major elements of static equipments. So, based on the integrity of safety management for the petroleum or petrochemical plants and reduction of the operation risks, some objective schemes of the systematic failure evaluations and assessments should be established in order to optimize the resources of inspection and maintenance. However, performing the inspections based on the conventional methodologies, some uncontrolled factors which caused by the environments and inspection methods may exist and affect the assessment of the estimated corrosion rate. If the influences of the uncontrolled factors were not considered and compensated in the assessment of the estimated corrosion rate, some underestimate or unreasonable results would be obtained which lead potential risks may exist in the plants. Moreover, the measured data of some parameters, for example, operation pressure, corrosion condition, allowable stress, which were used to evaluate the estimated corrosion rate of the pressure components may exhibit a normal or non-normal distribution. Under such circumferences, if one used the nominal values of the measured parameters to assessment the safety conditions of the pressure components, potential risks may exist in the petroleum or petrochemical plants at the final stage of long-term operation. With an eye to obtain more conservative and objective assess results for pressure equipments in the long-term operation, three subjects will be differentiated between the evaluation of estimated corrosion rate, failure probability of pressure vessels and pressure safety valve (PSVs). First, based on the pressure boundaries suffered from general corrosion, a statistical methodology was proposed to modify the assessment of estimated corrosion rates for the pressure components in conventional methodology. Furthermore, the obtained results of the estimated corrosion rates will be used to assess the failure probability of pressure components based on the upper limited value. By adopting First Order Second Moment (FOSM) method, the failure probability was approached for the pressure components in long term operation. Moreover, for the sake of optimize the inspection and maintenance resources based on the acceptable risk of the plant owners, typical semi-quantitative risk based inspection (RBI) methodology to each pressure vessel are proposed in safety management based on the approached failure probability. Besides, the final protection for the pressure equipments when the pressure systems were upset - pressure safety valves (PSVs), are also play important roles to system evaluation and safety management for pressurized system. So, follow the semi-quantitative RBI methodology, the objective evaluation schemes together with the suggested inspection interval were conservatively established. Based on the conclusion of the studies, few pressure components with high failure probability will raise the operation risk of the pressurized system. It is an effective way to reduce the operation risk of the pressurized system by shift the limited resource of inspection/maintenance on the pressure components with high risk and obtain further control with effective strategies. Moreover, the conclusion also shows the prospective inspection intervals of PSVs which time-based strategy according to the local regulations (2-year based) should be change to condition-based strategy to reduce the operation risk.
7

Underwater FRP repair of corrosion damaged prestressed piles

Suh, Kwangsuk 01 June 2006 (has links)
The goal of the dissertation was to quantify the role of FRP in repairing corroded prestressed piles in a marine environment and to demonstrate the feasibility of using it for field repairs. Three laboratory studies and two field demonstration projects were undertaken to meet this goal.In the first study, corroded specimens were repaired under water and tests conducted to determine the extent of strength retained immediately after wrapping and after further accelerated corrosion. Results showed that the underwater wrap was effective in restoring and maintaining lost capacity in both situations.The second study attempted to determine the effectiveness of FRP for specimens where corrosion had initiated but with no visible signs of distress. In the study, 22 one-third scale model of prestressed piles fabricated with cast-in-chlorides were wrapped at 28 days and exposed to simulated tidal cycles outdoors for nearly three years. Two materials -- carbon and glass were evaluated and the number of layers varied from 1 to 4. Results of gravimteric tests showed that the metal loss in FRP wrapped specimens was about a quarter of that in identical unwrapped controls indicating its effectiveness in this application.The third study attempted to identify the most suitable pre-wrap repair. For this purpose, 26 scale model prestressed specimens were first corroded to a targeted metal loss of 25%, repaired and then exposed to simulated hot salt water tidal cycles for over two years. Two disparate types of repairs were evaluated -- an elaborate full repair and a simpler epoxy injection repair. Results of ultimate and gravimetric tests conducted at the end of the exposure showed that the performance of the full and epoxy injection repairs were comparable but vastly superior compared to identical unwrapped controls.Two field studies were conducted in which full-sized corroding piles were instrumented and wrapped to monitor post-wrap performance. Corrosion rate measurements indicated that rates were lower for wrapped piles compared to identical unwrapped piles. Overall, the study demonstrated that underwater wrapping of piles using FRP is viable and a potentially cost effective method of pile repair in a marine environment.
8

Hodnocení koroze u vybraných typů hořčíkových slitin / Evaluation of Corrosion on Selected Magnesium Alloys

Pořický, Vladislav January 2009 (has links)
This master´s thesis is focused on classification of corrosion resistivity magnesium alloy type AZ91 in environment of salt vapour testing in corrosion chambers. For tests were used samples of magnesium alloy manufactured by three different methods of casting: cast-iron mold, die vacuum casting, die casting without vacuum and method of die casting with additional pressure (squeeze casting). In this work was accomplished metallographic evaluation of corrosion attack and detailed analysis of corrosion products. Conclusions of exposits tests are assembled of analysis of influence of corrosion environment on structure of alloy. On the basis of these conclusions of corrosion tests were evaluated influences of corrosion speed [mm/year] on time [hours] for individual states of magnesium alloy.
9

Hodnocení koroze u vybraných typů hliníkových slitin pro letecký průmysl / Evaluation of corrosion on selected aluminium alloys

Skýba, Pavel Unknown Date (has links)
The thesis focuses on the corrosion research of AlCu4Mg1 aluminium alloys of square shape and sheet metal coated in 99.5% aluminium. The theoretical part deals with the characteristics of aluminium, the classification and naming of aluminium alloys and the impact of admixtures on aluminium alloys. In the following chapter a general introduction to metal corrosion, its differentiation according to the type of corrosion attack, mechanisms of corrosion, the impact of corrosive environment, according to the choice of anti-corrosion protection, etc. is given. The main part is devoted to the corrosion of aluminium with a special importance of the impact of admixtures on aluminium alloys, the types of corrosion attack, the impact of corrosive environment as well as of the anti-corrosion protection of aluminium alloys. The corrosion tests in controlled atmosphere are considered in the next chapter, while the last one deals with the evaluation methodology of the process of corrosion. At the beginning of the experimental part all the used samples and materials are introduced. The thesis continues then with an overview and a description of the methods used for experiments. The measurement procedure and the results of the experiments are presented in the following chapter that focuses on the metallographic analysis of the aluminium alloy samples before the experiment and after the corrosion attack. The main part of the chapter deals with the dependence of corrosion speed of the individual aluminium alloy samples on time after being exposed in the climate chamber and the salt fog chamber
10

A study on molten steel/slag/refractory reactions during ladle steel refining

Jansson, Sune January 2005 (has links)
QC 20101203

Page generated in 0.0863 seconds