Spelling suggestions: "subject:"countercurrent flow"" "subject:"countercurrents flow""
1 |
A Mechanistic Model for Flooding in Vertical TubesHogan, Kevin J. 2009 August 1900 (has links)
In a counter-current two-phase flow system, flooding can be defined as the onset
of flow reversal of the liquid component which results in an upward co-current flow.
Flooding in the surge line of pressurized water reactors poses a significant technical
challenge in the analysis of several postulated nuclear reactor accident scenarios.
Despite the importance of flooding in these analyses, previous work does not
identify a universally accepted rigorous physics-based model of flooding, even for
the simple case of flooding in adiabatic, vertical tubes. This can be attributed to
a lack of conclusive understanding of the physics of two-phase counter-current flow,
specifically the mechanism of flooding, and the large amount of uncertainty among
data from various flooding experiments. This deficiency in phenomenological and
experimental knowledge has led to the use of many empirical and semi-empirical
correlations for specific system conditions and geometries. The goal of this work
is the development of a model for flooding in vertical, adiabatic tubes from first
principles.
To address a source of uncertainty in the analysis of flooding, a model for the
prediction of average film thickness in annular co- and counter-current flows has been
developed by considering the conservation of momentum of the liquid and gas flows.
This model is shown to be a quantitative improvement over the most commonly used
models, those of Nusselt and Belkin, Macleod, Monrad, and Rothfus. The new model
better considers the effects of interfacial shear and tube curvature by using closure
relations known to represent forces appropriately in co- and counter-current flow. Previous work based on semi-empirical flooding models has been analyzed to
develop a new theory on the hydrodynamic mechanism which causes flooding. It is
postulated that the growth of an interfacial wave due to interfacial instability results
in a flow reversal to ensure that momentum is conserved in the counter-current flow
system by causing a partial or complete co-current flow.
A model for the stability of interfacial waves in a counter-current flow system
is proposed and has been developed herein. This model accurately represents the
geometric and flow conditions in vertical adiabatic tubes and has been shown to have
limits that are consistent with the physical basis of the system. The theory of waves
of finite amplitude was employed to provide closure to an unknown parameter in
the new model, the wave number of the wave that generates the interfacial instabil-
ity. While this model underpredicts the flooding superficial gas velocity, the result
is a conservative estimate of what conditions will generate flooding for a system.
In the context of the analysis of a nuclear reactor, specifically a pressurized water
reactor, conservatism means that the gas flow rate predicted to cause flooding for
a fixed liquid flow rate will be less than the flow rate found experimentally, mean-
ing that liquid delivery to the core would be safely underestimated. Future work
includes the improvement of the closure relation for the limiting wave number that
will cause unstable interfacial waves, as well as an assessment of the applicability of
the stability-based model to flooding in the presence of phase change and flooding
in complex geometries.
|
2 |
Two-phase flow experiments in a model of the hot leg of a pressurised water reactorSeidel, T., Beyer, M. 14 March 2012 (has links) (PDF)
In order to investigate the two-phase flow behaviour in a complex reactor-typical geometry and to supply suitable data for CFD code validation, a model of the hot leg of a pressurised water reactor was built at FZD. The hot leg model is operated in the pressure chamber of the TOPFLOW test facility, which is used to perform high-pressure experiments under pressure equilibrium with the inside atmosphere of the chamber. This technique makes it possible to visualise the two-phase flow through large windows, also at reactor-typical pressure levels. In order to optimise the optical observation possibilities, the test section was designed with a rectangular cross-section.
Experiments were performed with air and water at 1.5 and 3.0 bar at room temperature as well as with steam and water at 15, 30 and 50 bar and the corresponding saturation temperature (i.e. up to 264°C). The total of 194 runs are divided into 4 types of experiments covering stationary co-current flow, counter-current flow, flow without water circulation and transient counter-current flow limitation (CCFL) experiments.
This report provides a detailed documentation of the experiments including information on the experimental setup, experimental procedure, test matrix and on the calibration of the measuring devices. The available data is described and data sheets were arranged for each experiment in order to give an overview of the most important parameters. For the cocurrent flow experiments, water level histograms were arranged and used to characterise the flow in the hot leg. In fact, the form of the probability distribution was found to be sensitive to the boundary conditions and, therefore, is useful for the CFD comparison.
Furthermore, the flooding characteristics of the hot leg model plotted in terms of the classical Wallis parameter or Kutateladze number were found to fail to properly correlate the data of the air/water and steam/water series. Therefore, a modified Wallis parameter is proposed, which takes the effect of viscosity into account.
|
3 |
Modeling of Multiphase Flow in the Near-Wellbore Region of the Reservoir under Transient ConditionsZhang, He 2010 May 1900 (has links)
In oil and gas field operations, the dynamic interactions between reservoir and wellbore cannot be ignored, especially during transient flow in the near-wellbore region. As gas hydrocarbons are produced from underground reservoirs to the surface, liquids can come from condensate dropout, water break-through from the reservoir, or vapor condensation in the wellbore. In all three cases, the higher density liquid needs to be transported to the surface by the gas. If the gas phase does not provide sufficient energy to lift the liquid out of the well, the liquid will accumulate in the wellbore. The accumulation of liquid will impose an additional backpressure on the formation that can significantly affect the productivity of the well. The additional backpressure appears to result in a "U-shaped" pressure distribution along the radius in the near-wellbore region that explains the physics of the backflow scenario. However, current modeling approaches cannot capture this U-shaped pressure distribution, and the conventional pressure profile cannot explain the physics of the reinjection.
In particular, current steady-state models to predict the arrival of liquid loading, diagnose its impact on production, and screen remedial options are inadequate, including Turner's criterion and Nodal Analysis. However, the dynamic interactions between the reservoir and the wellbore present a fully transient scenario, therefore none of the above solutions captures the complexity of flow transients associated with liquid loading in gas wells. The most satisfactory solution would be to couple a transient reservoir model to a transient well model, which will provide reliable predictive models to link the well dynamics with the intermittent response of a reservoir that is typical of liquid loading in gas wells. The modeling work presented here can be applied to investigate liquid loading mechanisms, and evaluate any other situation where the transient flow behavior of the near-wellbore region of the reservoir cannot be ignored, including system start-up and shut-down.
|
4 |
Two-phase flow experiments in a model of the hot leg of a pressurised water reactorSeidel, Tobias, Vallée, Christoph, Lucas, Dirk, Beyer, Matthias, Deen, Darlianto 26 August 2010 (has links) (PDF)
In order to investigate the two-phase flow behaviour in a complex reactor-typical geometry and to supply suitable data for CFD code validation, a model of the hot leg of a pressurised water reactor was built at FZD. The hot leg model is operated in the pressure chamber of the TOPFLOW test facility, which is used to perform high-pressure experiments under pressure equilibrium with the inside atmosphere of the chamber. This technique makes it possible to visualise the two-phase flow through large windows, also at reactor-typical pressure levels. In order to optimise the optical observation possibilities, the test section was designed with a rectangular cross-section.
Experiments were performed with air and water at 1.5 and 3.0 bar at room temperature as well as with steam and water at 15, 30 and 50 bar and the corresponding saturation temperature (i.e. up to 264°C). The total of 194 runs are divided into 4 types of experiments covering stationary co-current flow, counter-current flow, flow without water circulation and transient counter-current flow limitation (CCFL) experiments.
This report provides a detailed documentation of the experiments including information on the experimental setup, experimental procedure, test matrix and on the calibration of the measuring devices. The available data is described and data sheets were arranged for each experiment in order to give an overview of the most important parameters. For the cocurrent flow experiments, water level histograms were arranged and used to characterise the flow in the hot leg. In fact, the form of the probability distribution was found to be sensitive to the boundary conditions and, therefore, is useful for the CFD comparison.
Furthermore, the flooding characteristics of the hot leg model plotted in terms of the classical Wallis parameter or Kutateladze number were found to fail to properly correlate the data of the air/water and steam/water series. Therefore, a modified Wallis parameter is proposed, which takes the effect of viscosity into account.
|
5 |
Investigation Of Air Bubble Motion In Counter-current Water Flow ConditionsBezdegumeli, Ugur 01 January 2003 (has links) (PDF)
In this thesis study, air bubble motion in counter-current water flow conditions in a
vertical pipe is investigated experimentally. For this purpose, a test set-up was designed and constructed. Images of motions of single bubbles, having different diameters in the range of 3.0-4.8 mm, generated by specially designed bubble injectors were recorded by using a monochrome camera, an image capture card and a PC. Recorded video images were processed to obtain the necessary data for the The purpose of the study is to determine
variation as a function of the equivalent bubble diameter, water flow velocity and
related dimensionless numbers / Reynolds, Re / Eö / tvö / s, Eo / and Weber, We, and is to investigate the bubble shapes and bubble travel paths.
Bubble behaviour was investigated at six different counter-current water flow
velocities (6.5 cm/s, 7.9 cm/s, 10.5 cm/s, 12.9 cm/s, 15.4 cm/s, and 18.2 cm/s) in addition to stagnant water condition which is taken as the reference case. The direction of the bubble motion is upwards and the direction of the water flow is downwards (i.e. counter-current). Distilled water was used in the experiments.
The results of this thesis study for the stagnant water condition have shown good consistency with the previous theoretical and experimental studies found in the literature. For the studied range of bubble diameters, it is observed that the bubble average relative velocity for a certain bubble diameter is less under counter-current water flow conditions than that under stagnant water condition and the drag
coefficient values for a certain bubble diameter is higher under counter-current
water flow conditions than those under stagnant water condition.
|
6 |
STUDY OF THE THERMAL STRATIFICATION IN PWR REACTORS AND THE PTS (PRESSURIZED THERMAL SHOCK) PHENOMENONRomero Hamers, Adolfo 20 March 2014 (has links)
In the event of hypothetical accident scenarios in PWR, emergency strategies have to be mapped out, in order to guarantee the reliable removal of decay heat from the reactor core, also in case of component breakdown. One essential passive heat removal mechanism is the reflux condensation cooling mode. This mode can appear for instance during a small break loss-of-coolant-accident (LOCA) or because of loss of residual heat removal (RHR) system during mid loop operation at plant outage after the reactor shutdown.
In the scenario of a loss-of-coolant-accident (LOCA), which is caused by the leakage at any location in the primary circuit, it is considered that the reactor will be depressurized and vaporization will take place, thereby creating steam in the PWR primary side. Should this lead to ¿reflux condensation¿, which may be a favorable event progression, the generated steam will flow to the steam generator through the hot leg.
This steam will condense in the steam generator and the condensate will flow back through the hot leg to the reactor, resulting in counter-current steam/water flow. In some scenarios, the success of core cooling depends on the behaviour of this counter-current flow.
Over several decades, a number of experimental and theoretical studies of counter-current gas¿liquid two-phase flow have been carried out to understand the fundamental aspect of the flooding mechanism and to prove practical knowledge for the safety design of nuclear reactors. Starting from the pioneering paper of Wallis (1961), extensive CCFL data have been accumulated from experimental studies dealing with a diverse array of conditions
A one-dimensional two field model was developed in order to predict the counter-current steam and liquid flow that results under certain conditions in the cold leg of a PWR when a SBLOCA (small break loss of coolant accident) in the hot leg is produced.
The counter-current model that has been developed can predict the pressure, temperature, velocity profiles for both phases, also by taking into account the HPI injection system in the cold leg under a counter-current flow scenario in the cold leg. This computer code predicts this scenario by solving the mass, momentum and energy conservation equations for the liquid and for the steam separately, and linking them by using the interfacial and at the steam wall condensation and heat transfer, and the interfacial friction as the closure relations.
The convective terms which appear in the discretization of the mass and energy conservation equations, were evaluated using the ULTIMATE-SOU (second order upwinding) method. For the momentum equation convective terms the ULTIMATE-QUICKEST method was used.
The steam-water counter-current developed code has been validated using some experimental data extracted from some previously published articles about the direct condensation phenomenon for stratified two-phase flow and experimental data from the LAOKOON experimental facility at the Technical University of Munich. / Romero Hamers, A. (2014). STUDY OF THE THERMAL STRATIFICATION IN PWR REACTORS AND THE PTS (PRESSURIZED THERMAL SHOCK) PHENOMENON [Tesis doctoral]. Editorial Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/36536
|
7 |
Two-Phase Flow Experiments on Counter-Current Flow Limitation in a model of the Hot Leg of a Pressurized Water Reactor (2015 test series)Beyer, Matthias, Lucas, Dirk, Pietruske, Heiko, Szalinski, Lutz 15 February 2017 (has links) (PDF)
Counter-Current Flow Limitation (CCFL) is of importance for PWR safety analyses in several accident scenarios connected with loss of coolant. Basing on the experiences obtained during a first series of hot leg tests now new experiments on counter-current flow limitation were conducted in the TOPFLOW pressure vessel. The test series comprises air-water tests at 1 and 2 bar as well as steam-water tests at 10, 25 and 50 bar. During the experiments the flow structure was observed along the hot leg model using a high-speed camera and web-cams. In addition pressure was measured at several positions along the horizontal part and the water levels in the reactor-simulator and steam-generator-simulator tanks were determined.
This report documents the experimental setup including the description of operational and special measuring techniques, the experimental procedure and the data obtained.
From these data flooding curves were obtained basing on the Wallis parameter. The results show a slight shift of the curves in dependency of the pressure. In addition a slight decrease of the slope was found with increasing pressure. Additional investigations concern the effects of hysteresis and the frequencies of liquid slugs. The latter ones show a dependency on pressure and the mass flow rate of the injected water.
The data are available for CFD-model development and validation.
|
8 |
CFD MODELING OF MULTIPHASE COUNTER-CURRENT FLOW IN PACKED BED REACTOR FOR CARBON CAPTUREYang, Li 01 January 2015 (has links)
Packed bed reactors with counter-current, gas-liquid flows have been considered to be applicable in CO2 capture systems for post-combustion processing from fossil-fueled power production units. However, the hydrodynamics within the packing used in these reactors under counter-current flow has not been assessed to provide insight into design and operational parameters that may impact reactor and reaction efficiencies. Hence, experimental testing of a laboratory-scale spherical ball, packed bed with two-phase flow was accomplished and then a meso-scale 3D CFD model was developed to numerically simulate the conditions and outcomes of the experimental tests. Also, the hydrodynamics of two-phase flow in a packed bed with structured packing were simulated using a meso-scale, 3D CFD model and then validated using empirical models.
The CFD model successfully characterized the hydrodynamics inside the packing, with a focus on parameters such as the wetted surface areas, gas-liquid interactions, liquid distributions, pressure drops, liquid holdups, film thicknesses and flow regimes. The simulation results clearly demonstrated the development of and changes in liquid distributions, wetted areas and film thicknesses under various gas and liquid flow rates. Gas and liquid interactions were observed to occur at the interface of the gas and liquid through liquid entrainment and droplet formation, and it became more dominant as the Reynolds numbers increased. Liquid film thicknesses in the structured packing were much thinner than in the spherical ball packing, and increased with increasing liquid flow rates. Gas flow rates had no significant effect on film thicknesses. Film flow and trickle flow regimes were found in both the spherical ball and structured packing. A macro-scale, porous model was also developed which was less computationally intensive than the meso-scale, 3D CFD model.
The macro-scale model was used to study the spherical ball packing and to modify its closure equations. It was found that the Ergun equation, typically used in the porous model, was not suitable for multi-phase flow. Hence, it was modified by replacing porosity with the actual pore volume within the liquid phase; this modification successfully accounted for liquid holdup which was predicted via a proposed equation.
|
9 |
Two-phase flow experiments in a model of the hot leg of a pressurised water reactorSeidel, Tobias, Vallée, Christoph, Lucas, Dirk, Beyer, Matthias, Deen, Darlianto January 2010 (has links)
In order to investigate the two-phase flow behaviour in a complex reactor-typical geometry and to supply suitable data for CFD code validation, a model of the hot leg of a pressurised water reactor was built at FZD. The hot leg model is operated in the pressure chamber of the TOPFLOW test facility, which is used to perform high-pressure experiments under pressure equilibrium with the inside atmosphere of the chamber. This technique makes it possible to visualise the two-phase flow through large windows, also at reactor-typical pressure levels. In order to optimise the optical observation possibilities, the test section was designed with a rectangular cross-section.
Experiments were performed with air and water at 1.5 and 3.0 bar at room temperature as well as with steam and water at 15, 30 and 50 bar and the corresponding saturation temperature (i.e. up to 264°C). The total of 194 runs are divided into 4 types of experiments covering stationary co-current flow, counter-current flow, flow without water circulation and transient counter-current flow limitation (CCFL) experiments.
This report provides a detailed documentation of the experiments including information on the experimental setup, experimental procedure, test matrix and on the calibration of the measuring devices. The available data is described and data sheets were arranged for each experiment in order to give an overview of the most important parameters. For the cocurrent flow experiments, water level histograms were arranged and used to characterise the flow in the hot leg. In fact, the form of the probability distribution was found to be sensitive to the boundary conditions and, therefore, is useful for the CFD comparison.
Furthermore, the flooding characteristics of the hot leg model plotted in terms of the classical Wallis parameter or Kutateladze number were found to fail to properly correlate the data of the air/water and steam/water series. Therefore, a modified Wallis parameter is proposed, which takes the effect of viscosity into account.
|
10 |
Two-phase flow experiments in a model of the hot leg of a pressurised water reactorSeidel, T., Beyer, M. January 2011 (has links)
In order to investigate the two-phase flow behaviour in a complex reactor-typical geometry and to supply suitable data for CFD code validation, a model of the hot leg of a pressurised water reactor was built at FZD. The hot leg model is operated in the pressure chamber of the TOPFLOW test facility, which is used to perform high-pressure experiments under pressure equilibrium with the inside atmosphere of the chamber. This technique makes it possible to visualise the two-phase flow through large windows, also at reactor-typical pressure levels. In order to optimise the optical observation possibilities, the test section was designed with a rectangular cross-section.
Experiments were performed with air and water at 1.5 and 3.0 bar at room temperature as well as with steam and water at 15, 30 and 50 bar and the corresponding saturation temperature (i.e. up to 264°C). The total of 194 runs are divided into 4 types of experiments covering stationary co-current flow, counter-current flow, flow without water circulation and transient counter-current flow limitation (CCFL) experiments.
This report provides a detailed documentation of the experiments including information on the experimental setup, experimental procedure, test matrix and on the calibration of the measuring devices. The available data is described and data sheets were arranged for each experiment in order to give an overview of the most important parameters. For the cocurrent flow experiments, water level histograms were arranged and used to characterise the flow in the hot leg. In fact, the form of the probability distribution was found to be sensitive to the boundary conditions and, therefore, is useful for the CFD comparison.
Furthermore, the flooding characteristics of the hot leg model plotted in terms of the classical Wallis parameter or Kutateladze number were found to fail to properly correlate the data of the air/water and steam/water series. Therefore, a modified Wallis parameter is proposed, which takes the effect of viscosity into account.
|
Page generated in 0.0929 seconds