• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Étude expérimentale et numérique du comportement des joints à lèvre / Experimental and numerical study of the rotary lip seals behavior

Gadari, M’hammed El 04 December 2013 (has links)
Cela fait environ soixante ans que l'on s'intéresse à la compréhension et à la modélisation du comportement Elastohydrodynamique (EHD) des joints à lèvres. Cependant, on peut considérer que, jusqu'à présent, leur modélisation n'a pas été totalement et rigoureusement traitée. En effet, même si de nombreuses études ont été consacrées à cette modélisation, plusieurs questions ont été soulevées et font toujours l'objet de controverses entre les chercheurs, à savoir l'impact sur les performances des joints à lèvre de l'effet des surfaces texturées de l'arbre, de la loi adoptée pour le comportement mécanique des joints à lèvre, de la démarche utilisée pour l'élaboration de la matrice de compliance (matrice de souplesse), de l'importance de supposer l'arbre lisse ou rugueux, ainsi que la valeur du rapport entre la largeur du contact et la longueur d'onde du défaut suivant la direction circonférentielle de la lèvre.Dans cette thèse, nous avons tenté d'apporter de façon rigoureuse des réponses claires et précises à toutes ces questions en élaborant et en validant un outil de simulation EHD complet pour les joints à lèvre qui tienne compte de presque tous les paramètres, à savoir une loi de comportement du matériau du joint précise, une matrice de souplesse rigoureusement validée et un arbre qui peut être lisse, rugueux et/ou texturé. De plus, un second modèle analytique est proposé. Il traite le comportement vibratoire du "squeeze film", en tenant compte de la non linéarité des caractéristiques intrinsèques du joint et du film. / It's about sixty years that we are interested in understanding and modeling the Elastohydrodynamic behavior (EHD) of rotary lip seals. However, we can consider that, until now, their modeling has not been accurately treated. Even though many studies have been devoted to this model, several questions have been raised and are still the subject of controversy among researchers, namely the parameters influencing on the rotary lip seals performance, such as: the shaft surface textured, the law adopted for the mechanical behavior of lip seals, the approach used to develop the matrix of compliance, the importance of assuming the smooth or rough shaft, and finally the ratio between the width of contact and the wavelength according the circumferential direction of the lip roughness.The main goal of this thesis is to answer rigorously these questions by developing and validating a numerical tool for EHD rotary lip seals modeling, that takes into account: the lip law behavior, the compliance matrix rigorously validated by assuming smooth shaft case, or rough and textured shaft case. In addition, an analytical approach is proposed, models the vibratory behavior of the "squeeze film". This implies a nonlinear comportment that is taken into account.
2

Relargage d’ions métalliques après l’arthroplastie de la hanche à grand diamètre avec couple de frottement métal sur métal

Amzica, Traian 08 1900 (has links)
La dégénérescence articulaire sévère de la hanche est une pathologie fréquente et son traitement ultime est le remplacement prothétique. L’arthroplastie la plus répandue au monde est la prothèse totale de hanche (PTH) avec un couple de frottement métal-sur-polyéthylène (MPE). Cependant ce type d’intervention présente une longévité limitée à cause de l’usure de PE et ne convient pas aux patients actifs souffrant de coxarthrose sévère tôt dans leur vie. Afin de palier à ce problème, une nouvelle génération de surfaces de frottement métal-sur-métal (MM) est actuellement employée. Ces surfaces de frottement sont utilisées en PTH avec tête de 28 mm, en resurfaçage (RH) et avec la PTH à tête de grand diamètre. Alors qu’il y a beaucoup d’évidence à l’égard du bon fonctionnement des implants PTH 28 mm et du RH, les données quant aux performances in vivo des PTH MM à grand diamètre manquent. Malgré cela, ces implants sont utilisés à grande échelle. Dans un premier temps, l’objectif de ce travail de recherche était d’évaluer l’effet et de comparer les taux d’ions chrome (Cr) et cobalt (Co) chez des sujets porteurs de PTH MM à grand diamètre à ceux de 64 porteurs de RH, tous deux possédant des surfaces de frottement aux propriétés tribologiques identiques. Dans un deuxième temps, nous avons comparé les taux ioniques (Cr, Co et titane (Ti)) entre quatre PTH MM à grand diamètre provenant de fabricants différents (Zimmer, DePuy, Smith & Nephew et Biomet). Les mesures d’ions étaient effectuées dans le sang entier dans un laboratoire indépendant par la technique de spectrophotométrie de masse à haute résolution HR-ICP-MS, pour l’ensemble de ce travail de recherche. Les deux comparaisons ont démontré le rôle crucial joué par la modularité au niveau de la jonction tête-col des PTH MM à grand diamètre. En effet, des écarts considérables dans les concentrations ioniques de Co ont été retrouvés entre les RH et PTH Durom ayant un couple de frottement identique, ainsi qu’entre les 4 différents designs de PTH MM à grand diamètre comparés entre eux. La PTH MM à grand diamètre Durom était la moins favorable alors que celle de Biomet était la plus performante. Nos observations démontrent que des sources inattendues comme la jonction tête-col de certains implants PTH MM à grand diamètre peuvent contribuer au relargage ionique systémique. Une meilleure compréhension de ce phénomène est indispensable avant l’utilisation clinque de nouveaux implants de ce type. / The treatment for advanced degenerative hip disease consists in replacing the native joint with artificial implants. This is a very common procedure and the type of arthroplasty most practiced worldwide is metal-on-polyethylene (MOPE) total hip replacement (THR). However, this type of bearing has limited lifespan and is not adapted for active patients struggling with hip osteoarthritis early in their lives. In order to increase implant longevity, new generation, metal-on–metal (MOM) bearing surfaces is used nowadays in this particular population. These MOM bearings are used in 28 mm THR, in resurfacing hip arthroplasty (RH) and in large diameter head THR. Although consistent results have been obtained with the 28 mm THR and RH, large diameter head THR are increasingly used despite lack of scientific data about their performances. The main purpose of our first paper was to compare chromium (Cr) and cobalt (Co) concentrations among patients implanted with large diameter head THR and with RH. In this case, both bearing surfaces presented identical tribological properties. In the second paper, we compared performances in terms of ion release (Cr, Co and titanium (Ti)) from four different manufacturers of large diameter head THR systems (Zimmer, DePuy, Smith & Nephew and Biomet). Whole blood was used for all samples and ion measurements were conducted by an independent laboratory in a blinded fashion, using high-resolution inductive coupled plasma mass spectrophotometry (HR-ICP-MS). Both papers have emphasized the crucial role played by modularity at the head-neck junction in metal ion release from large diameter THR MOM bearings. In fact, significant differences were found in Co ion concentration between large head THR and HRA as well as among the different designs of large head THRs. Briefly, the Durom large head THR system was the least favorable implant while the Biomet large head THR system showed the best results. Our results prove that systemic ion release might origin from surprising sources such as modularity at the head-neck junction in patients implanted with certain large head MOM THR systems. A better comprehension of head-neck junction biomechanics is necessary before clinical use of such new devices.
3

Angle modeling of a rotating machine. Application to wind turbine surveillance / Modélisation angulaire d'une machine tournante. Application à la surveillance d'éoliennes

Gomez Chirinos, José Luis 01 September 2017 (has links)
Ce travail de recherche s'inscrit dans le cadre de la surveillance des machines tournantes en régime non stationnaire et plus particulièrement la détection des défauts de roulement. Il se focalise sur la modélisation et l'analyse des variations de la vitesse de rotation instantanée. Les modèles numériques développés s'appuient sur une approche originale dite " angulaire " qui introduit explicitement les degrés de rotation libres de la machine et permet de s'affranchir de condition de fonctionnement en régime stationnaire. Un modèle de roulement à billes à gorge profonde a été développé couplant les efforts de contact normaux et tangentiels grâce à l'introduction du phénomène de résistance au roulement. Ce couplage permet d'expliquer l'origine des fluctuations de vitesse de rotation en présence de défaut de bague extérieure, phénomènes constatés expérimentalement : la présence d'un défaut sur une bague modifie périodiquement le couple de frottement. La modélisation de la liaison par engrenages est plus classique, la problématique a été de s'assurer qu'elle était compatible avec l'approche angulaire utilisée dans ces travaux. Le couplage des éléments de roulement et d'engrenage dans un modèle simple a montré que la présence de défauts de roulement provoque des variations des efforts radiaux ce qui modifie les efforts d'engrènement et en conséquence perturbe également la vitesse de rotation. Un modèle simplifié d'une éolienne a été réalisé et utilisé pour tester et valider des indicateurs spectraux de surveillance en conditions de fonctionnement non stationnaires. La comparaison avec des mesures expérimentales issues d'une éolienne a montré la robustesse du modèle. Il peut donc être exploité comme un outil d'analyse phénoménologique et de test d'indicateurs de surveillance. Il a par exemple permis de montrer l'importance des conditions de fonctionnement (charge et vitesse) sur le niveau des indicateurs utilisés en surveillance. Si besoin, les développements proposés peuvent être étendus sans difficulté à des modèles plus complexes de roulements, d'engrènements et de structures d'accueil de ces éléments technologiques. / This work has been developed within the framework of non-stationary rotating machinery surveillance with emphasis on the detection of roller bearing defects. It focuses on the modeling and analysis of instantaneous angular speed variations. The numerical models developed are based on an ``angular" approach which introduces explicitly the machine's free body rotation degrees of freedom allowing simulations in non stationary operating conditions. A deep groove ball bearing model has been developed coupling tangential and normal forces by taking into account the rolling resistance phenomenon. This coupling allows to explain the origin of angular speed fluctuations in the presence of outer race roller bearing defects, phenomena that has been observed experimentally: a roller bearing defect periodically modifies the friction torque. The description of the gear mesh has been performed by means of a classic approach where the scientific issue has been to verify the compatibility with the angular modeling, cornerstone of this dissertation. Integration of the roller bearing and the gear modeling approaches into a simple mechanical architecture has shown that the presence of bearing defects provoking variations in the rolling element-races normal forces, modifies the gear mesh forces leading to perturbations of the angular speed. A simplified wind turbine model has been used for the test and validation of non stationary surveillance spectral indicators. The robustness of the model has been shown by means of a comparison with measurements performed on a wind turbine. It has allowed to show the importance of the operating conditions (load and speed), on the level of indicators used. This means the model may be used as a tool for phenomenological analyses as well as a device to test surveillance indicators. If needed, the approaches presented may be easily extended into more complex models of bearings, gears, casings and foundations.

Page generated in 0.0733 seconds