21

Service Policy Management for User-Centric Services in Heterogeneous Mobile Networks,

Avgeropoulos, Konstantinos January 2004 (has links)
The Session Initiation Protocol (SIP) is a signaling protocol for IP-based media services that will be the de facto standard for future media-over-IP services. Since SIP User Agents (UAs) support a limited number of service types (usually one or two), we assume that the future user will need to operate several UAs simultaneously. These UAs will constitute the user's personal service network. In this thesis, we investigate architectures for policy-based management of this network so that it can be used in an efficient manner. To achieve this, we propose a new SIP entity, called the SIP Service Manager (SSM), which lies in the core of the management system. Finally, we evaluate our proposal by implementing one version of the SIP Service Manager. / Session Initiation Protocol (SIP) är ett signaleringsprotokoll för IP-baserade mediatjänster som kommer att bli "de facto"-standard för framtida "media-över-IP"-tjänster. Då SIP User Agents (UAs) stöder ett begränsat antal typer av tjänster (oftast en eller två), antar vi att framtida användare kommer att behöva använda sig av flera UAs samtidigt. Dessa UAs utgör en användares personliga tjänstenätverk. I denna rapport, undersöker vi arkitekturer för policybaserad hantering (management) av detta nätverk, så att det kan användas effektivt. För att uppnå detta, föreslår vi en ny SIP-enhet, kallad SIP Service Manager (SSM), som är placerad i kärnan av hanteringssystemet. Slutligen utvärderar vi vår föreslagna lösning genom att implementera en version av en SIP Service Manager.
22

Utvärdering av analys av pankreas-specifikt lipas hos hund och katt med Vcheck V200 : en prospektiv komparativ studie / Evaluation of analysis of pancreas-specific Lipase in dogs and cats with Vcheck V200 : a prospective comparative study

Carlsson, Felicia January 2021 (has links)
Pankreatit anses vara en vanligt förekommande sjukdom hos hundar och katter och kan diagnostiseras genom mätningar av koncentrationen Canine Pancreas-specific Lipase (cPL) respektive Feline Pancreas-specific Lipase (fPL) i serum. Utifrån dessa koncentrationer graderas patienten enligt normalvärde, gråzon eller indikation på pankreatit. Golden standardmetoden för att analysera cPL/fPL är Spec cPL respektive Spec fPL. Nya metoder har utvecklats för kvantitativ mätning av pankreas-specifik lipas såsom Vcheck V200, ett instrument, som analyserar cPL/fPL med en fluorescerande immunoassay. Syftet med studien var att utvärdera analys av cPL/fPL på Vcheck V200 samt jämföra resultatet från detta instrument med värdena från ett referenslaboratorium i Tyskland för att se om det fanns en signifikant skillnad mellan metoderna. Koncentrationen cPL i hundserum (n=37) och koncentrationen fPL i kattserum (n=29) analyserades på Vcheck V200. Dessa prover skickades även till referenslaboratoriet där analysen Spec cPL respektive Spec fPL utfördes. Spridningen var stor kring bias i Bland-Altman diagram för både cPL och fPL och jämförelsen mellan metoderna för de specifika koncentrationerna av cPL/fPL bedömdes vara statistiskt signifikant (p<0,05). 27% av hundproverna graderas olika enligt de båda metoderna och skillnaden var signifikant (p<0,05). 24% av kattproverna graderades olika men skillnaden var inte signifikant (p=0,257). Studien tyder på att jämförelsen mellan de båda metoderna var signifikant förutom vid graderingen av kattproverna. Beaktande detta och det faktum att kvalitetssäkringen brister vid analys av fPL på grund av avsaknad av kontroller kan i dagsläget inte cPL/fPL på Vcheck V200 ersätta den nuvarande golden standardmetoden, trots att ingen signifikant skillnad sågs vid gradering av kattprover. / Pancreatitis is a common disease in canine and felines and can be diagnosed by measuring the concentration of Canine Pancreas-specific Lipase (cPL) or Feline Pancreas-specific Lipase (fPL) in serum. Based on the concentration of cPL/fPL, the patient is then classified in different diagnostic categories (normal value, gray zone or indication of pancreatitis). Spec cPL and Spec fPL is currently the golden standard method for analysis of cPL and fPL. New methods have been developed for the quantitative measurement of pancreatic lipases. Vcheck V200, being one example, utilizing a fluorescent immunoassay for quantification of the lipase. The aim of this study was to evaluate the cPL and fPL analysis on the Vcheck V200 and to examine if there was a significant difference (p≤0,05) when comparing the result from Vcheck V200 with the results from a reference laboratory. The concentration of cPL (n=37) and fPL (n=29) in serum from canine or felines were analyzed using Vcheck V200. The samples were also sent to the reference laboratory where Spec cPL and Spec cPL were performed. A Bland-Altman plot comparison between the two methods showed a large spread for both analysis of cPL and fPL. Comparison of the specific values for analysis of cPL and fPL between the two methods revealed a significant difference (p<0,05). 27% of the dog samples were categorized differently according to the two methods and this difference was significant (p<0,05). 24% of the cat samples were categorized differently and no significant difference were observed (p=0,257). This study indicates that the difference between the two methods was significant, besides the classification of cat samples. Considering this and the lack of quality assurance regarding analysis of fPL due to lack of controls, the cPL/fPL analysis on Vcheck V200 cannot replace the Spec cPL or Spec fPL at present.
23

LOOP HEAT PIPE (LHP) MODELING AND DEVELOPMENT BY UTILIZING COHERENT POROUS SILICION (CPS) WICKS

HAMDAN, MOHAMMAD OMAR 17 April 2003 (has links)
No description available.
24

Contribution à la modélisation du réseau électrique domestique en vue de la caractérisation du canal de propagation CPL

Guezgouz, Djamel 13 December 2010 (has links) (PDF)
Le réseau électrique s'utilise aujourd'hui comme support de transmission des signaux Ethernet. C'est le concept des courants porteurs en ligne. Cette technique de transmission permet d'obtenir des débits supérieurs au Wifi. Cependant, la complexité des réseaux électriques et l'environnement électromagnétique domestique peuvent dégrader les performances de cette technologie. L'environnement électrique de l'habitat avec ses appareils électroménagers divers en font un milieu difficilement maitrisable. L'objectif est d'appréhender et de modéliser cet environnement et le comportement des équipements qui y sont déployés. Pour cela, ce mémoire présente plusieurs méthodes pour modéliser les lignes électriques dans l'habitat. Les modélisations existantes sont difficilement généralisables à un réseau électrique quelconque. Nous proposons une modélisation de type circuit électrique. Son intérêt réside dans la simplicité de l'outil de simulation d'un réseau électrique, réalisé par la mise en cascade de plusieurs blocs intégrés à la librairie SPICE. Les blocs SPICE proposés prennent en compte la dépendance fréquentielle des paramètres des quadripôles. Une étape de caractérisation expérimentale est développée pour implémenter ces blocs. Un réseau expérimental de test, constitué de différentes technologies de câble, a été caractérisé en termes de bruit, d'impédance et de pertes d'insertion. Le rayonnement émis lors d'une transmission CPL a aussi été mesuré.
25

Etude et Optimisation de Communications à Haut Débit sur Lignes d'Energie : Exploitation de la Combinaison OFDM/CDMA

Crussière, Matthieu 28 November 2005 (has links) (PDF)
Les travaux de recherche présentés dans cette thèse ont pour but l'étude et l'optimisation d'un système de communications à haut-débit sur lignes électriques, mettant en œuvre les techniques combinant l'OFDM et le CDMA. Cette étude s'inscrit dans un contexte d'exploitation de la boucle locale électrique pour l'accès à l'Internet domestique.<br /><br />La première partie du document est consacrée à l'étude des spécifications du système de communications. Un état de l'art sur les communications par courant porteur est tout d'abord proposé, accompagné d'une synthèse sur la structure du réseau des lignes électriques et les caractéristiques du canal de propagation. Les différents choix concernant le système à développer sont ensuite envisagés pour l'obtention de communications multiutilisateurs en liaison point-à-multipoint dans un environnement multicellulaire. La combinaison entre l'OFDM et le CDMA, appelée SS-MC-MA, est retenue et une structure de trame est proposée.<br /><br />La deuxième partie du document est dédiée à l'étude des procédés de synchronisation et d'estimation de canal. Les effets des erreurs de synchronisation sont en premier lieu identifiés et la tolérance du système aux défauts de rythme est spécifiée. La procédure de synchronisation du système est ensuite décrite et des algorithmes conjoints et innovants de synchronisation temporelle fine et d'estimation de canal sont proposés. Deux approches reposant sur une mise en œuvre de ces algorithmes dans le domaine fréquentiel et temporel sont alors comparées. <br /><br />La dernière partie traite, dans le cas de signaux SS-MC-MA, de l'allocation globale des différentes ressources du système, dans les cas mono- et multi-utilisateur avec une connaissance parfaite du canal à l'émission. Le principe des modulations adaptatives appliqué à la DMT est tout d'abord abordé et adapté au contexte de l'étude. En considérant une limitation de la densité spectrale de puissance d'émission, de nouveaux algorithmes d'allocation sont ensuite développés en mode SS-MC-MA. Il est alors démontré que la composante étalement permet une meilleure exploitation des énergies disponibles sur chaque sous-porteuse, et de transmettre alors un débit plus élevé que la DMT ou de rendre la communication plus robuste. Les nombreux résultats obtenus dans diverses configurations montrent que le système SS-MC-MA adaptatif proposé est plus performant que la DMT pour les réseaux CPL.
26

Contributions to the Improvement of Multiuser PLC Home Networks

Achaichia, Pierre 12 October 2012 (has links) (PDF)
During the past few years, Power Line Communications (PLC) have become a popular connectivity solution to answer the growing need of home networks for bandwidth. As wireless technologies, this solution spares the user from cabling its Local Area Network (LAN), by directly using the home power grid as a transmission medium. While PLC generally offer a larger coverage than Wireless Local Area Networks (WLAN), the capacity offered by current systems is not sufficient to simultaneously support bandwidth intensive streams. In this thesis, we aim at exploring various solutions for future PLC networks. Firstly, we aim at improving the spectral efficiency of the current systems' Physical (PHY) layer, where two modulation schemes are compared. On the one hand, we study the modulation deployed in current PLC networks, called windowed Orthogonal requency Division Multiplexing (OFDM), and we highlight the main limitation of this solution in the particular context of PLC. On the other hand, we show that and alternative solution, called OFDM/Offset Quadrature Amplitude Modulation (OQAM), offers some degrees of freedom which could highly benefit to PLC networks. Secondly, the study is oriented toward the Media Access Control (MAC) layer of PLC systems, considering a multiuser utilization of the network. In this second part, we aim at proposing allocation solutions that will allow a more efficient utilization of the limited and shared transmission resource. We firstly study the opportunity of defining an Orthogonal Frequency-Division Multiple Access (OFDMA) transmission scheme for point-to-multipoint transmissions, in order to increase data rates by taking advantage of the diversity between users' channels. Finally, the last Chapter is dedicated to the study of broadcast and multicast communications in PLC networks, where we show that a smart aggregation of the set of users to reach could greatly improve efficiency of multicast transmissions.
27

Prebiotic photoreduction and polymerization of cysteinyl peptides.

Xxx, Anju 11 October 2023 (has links)
Cysteinyl peptides likely played an important role in the prebiotic synthesis of cofactors, such as iron-sulfur clusters. However, cysteinyl peptides must be reduced in order to coordinate iron-sulfur clusters. Mixtures of ferric ions and cysteinyl peptides leads to the reduction of ferric to ferrous ions and the concomitant formation of disulfide bridged, oxidized cysteinyl peptides that are incapable of coordinating an iron-sulfur cluster. Here, we develop a photochemically driven solution to this problem. Lipoic acid (( R )-5-(1,2-dithiolane-3-yl)pentanoic acid), a molecule structurally similar to fatty acids, can be photochemically reduced and can subsequently reduce the oxidized cysteinyl peptides needed for the coordination of an iron-sulfur cluster. Other dithilane ring containing molecules possess similar activity to lipoic acid. The synthesis of small peptides containing cysteines, such as glutathione and GCG (Gly-Cys-Gly) is easy by both solid phase and solution phase methodologies. However, as the length of the peptide increases, the yield begins to decrease, especially for peptides containing cysteines due to oxidation. One solution could be to exploit a previously uncovered mechanism for the joining of peptides into longer peptides. Such mechanisms, referred to as CPL for catalytic peptide ligation, rely on either thiols or metals as catalysts and peptide nitriles as substrates. Thus far, CPL has only been exploited with non-cysteinyl peptides. In this thesis, we extend CPL to cysteine containing peptides by taking advantage of the templating effects of Zn2+. Longer peptides with properly spaced cysteines are frequently better able to stabilize iron-sulfur clusters in aqueous solution than shorter peptides. Coordination can either be complete or an open coordination position, filled by solvent, can be used to bind substrate. Two well-known examples of such an arrangement are the radical SAM (S-adenosylmethionine) enzyme and aconitase being an enzyme of the citric acid cycle. We designed and synthesized peptide sequences that could coordinate a [4Fe-4S]2+ cluster with three cysteinyl ligands, leaving an open coordination position. The stability of the [4Fe-4S] cluster was affected by the intermediates of the citric acid cycle. The iron-sulfur can be reconstituted with the long peptidyl sequences from proteins such as SLC25A39 which contains four cysteine ligands to form [2Fe-2S] cluster, which is necessary for glutathione transport from cytosol to mitochondria.
28

STUDY OF TRANSIENT BEHAVIOR OF THE EVAPORATOR OF THE MICRO LOOP HEAT PIPE AND MODIFICATIONS TO THE EXISTING GLOBAL MODEL

PONUGOTI, PRIYANKA 02 October 2006 (has links)
No description available.
29

Theoretical And Experimental Studies Of Capillary Pumped Loop And Loop Heat Pipe

Adoni, Abhijt Avinash 01 1900 (has links)
Capillary pumped loop (CPL) and loop heat pipe (LHP), are two-phase heat transport devices which rely on surface tension induced by a fine pore wick to drive a working fluid in a loop. These are based on a working principle similar to that of heat pipes -closed evaporation and condensation cycle being maintained by capillary pumping. CPLs and LHPs are gaining importance as a part of the thermal control system of modern high power spacecraft, electronic thermal management, cryogenics, etc. A mathematical model to simulate the thermo-hydraulic performance of CPLs and LHPs is developed to aid in the design of such a spacecraft thermal control system. In this study a unified mathematical model to estimate thermal and hydraulic performance of a CPL and an LHP -with a two-phase or a hard-filled reservoir is presented. The steady state model is based on conservation of energy and mass in the system. Heat exchanges between the loop and the surroundings and pressure drops in the loop are calculated. The constant conductance regime in a CPL or an LHP occurs when the reservoir is hard-filled. It also occurs in an LHP if the condenser is fully utilised. The heat leak across the wick becomes significant in a hard-filled LHP since the core is no longer saturated and hence the mass flow rate must be calculated using an energy balance on the outer surface of the wick. Theoretical studies indicate that the core of a hard-filled CPL and LHP is always sub-cooled. Hard-filled LHPs (with a bayonet) cannot be operated under all conditions. If the heat exchange between the compensation chamber (of an LHP with bayonet) and the ambient is small then such an LHP will not deprime if the hard-filling occurs before the condenser opens. Deprime due to hard-filling is not expected if it occurs after the condenser opens. A laboratory model is built to demonstrate the operation of these two devices and to correlate the theoretical predictions with the experimental observations. The CPL/LHP laboratory model is fabricated and designed so that different evaporator and reservoir designs can be integrated into the test-rig and tested with different working fluids. Experiments are conducted on a three-port CPL with a tubular axially grooved (TAG) evaporator. This CPL is operated with three different fluids -namely -Ammonia, Acetone and R134a. The CPL is operated for heat loads in the range of 75W to 400W with sink temperatures of -10◦C and 0◦C. The influence of reservoir temperature (35◦C and 43◦C) is also studied. The TAG evaporator is modified to operate in an LHP mode with R134a as the working fluid with heat loads in the range of 75W to 150W. This LHP does not exhibit typical “√” shaped operating characteristic due to large liquid inventory in the compensation chamber (CC). The R134a based LHP results suggest that large liquid inventory (in the CC) and absence of secondary wick significantly influence the thermal coupling between the core and the compensation chamber. Experiments are also conducted with a flat plate (FP) evaporator, in LHP operating mode, with Ammonia as the working fluid. This LHP can transport heat loads from 25W to 300W with a sink temperature at -15◦C. The experimental results indicate that ammonia is the best working fluid (moderate temperature regime) among all the working fluids tested, and that evaporation heat transfer coefficients in sintered Ni-wick are better. The correlation of the predicted temperatures on the transport lines and the saturation temperature (in LHPs) with the observations is good. Some of the salient conclusions from these experiments are that mass of charge can significantly influence the operating characteristics of a TAG LHP, even though the fluid in the CC is in two-phase condition. Theoretical predictions can be significantly affected when thermal and hydraulic development lengths in the condenser are comparable with the length of the sub-cooling section.
30

Refroidissement d'une armoire de Télécommunication avec Bouche Diphasique Thermosyphon

Mecheri, Boubakeur 17 February 2011 (has links) (PDF)
France Télécom possède des armoires de télécommunication dont la puissance est limitée à cause de la dissipation thermique des équipements actifs qui entraîne une augmentation de leur température interne. La puissance des équipements limite le nombre de clients qu'il est possible de connecter aux services des réseaux à hauts débits. En plus de cette contrainte, les armoires sont soumises à des effets liés au climat (ensoleillement) qui peuvent être sévères et difficiles à maîtriser. Ceci nécessite l'intégration de systèmes de refroidissement permettant de maintenir la température des composants en dessous de la limite imposée (55°C). C'est dans cet objectif que ce travail de thèse a été mené au sein du laboratoire FEMTO-ST en collaboration avec le service R&D de France Télécom à Lannion. Le refroidissement par changement de phase est favorisé pour maintenir la température de fonctionnement du système stable et pour être utilisé dans les systèmes à haute densité de puissance. Les boucles diphasiques sont des systèmes de refroidissement pour le contrôle thermique et fonctionnent passivement sans pompage mécanique du fluide caloporteur. Après une étude bibliographique sur les boucles de refroidissement diphasiques et leurs applications, on a constaté que les boucles thermosiphons sont particulièrement adaptées aux applications où le faible coût, l'efficacité énergétique et la fiabilité d'entretien sont souhaités. Cette étude a été conduite en suivant un cahier de charge proposé par France Télécom qui consiste à : (i) développer un modèle numérique permettant de modéliser les transferts échangés entre l'armoire de télécommunication et le milieu ambiant, (ii) mener une étude expérimentale en vue de concevoir une boucle thermosiphon pour le refroidissement d'armoires de télécommunication.Le mémoire de cette thèse montre la limitation des systèmes de refroidissement classiques utilisant des écoulements d'air en convection forcée ou autre fluides sans changement de phase. Un modèle numérique est développé afin de permettre la prédiction des températures à l'entrée des boitiers chauffants pour différentes conditions climatiques. Le choix est porté sur l'utilisation d'une modélisation par réseau nodal. La modélisation est effectuée en tridimensionnel et en régime transitoire. Nous avons également modélisé le rayonnement solaire auquel est soumise l'armoire de télécommunication. Le modèle développé a été validé en effectuant une comparaison entre les résultats issus de la modélisation et ceux obtenus à partir des expériences menées au laboratoire et à la plateforme CLIMA chez France Télécom. Les essais sont effectués en régime transitoire en imposant une puissance électrique et en faisant varier la température ambiante ou la densité de flux thermique solaire. L'ensemble des résultats obtenus ont permis de constituer une base de données. Le deuxième objectif fixé dans le cadre de ce travail de thèse est la conception d'un système de refroidissement sous forme d'une boucle thermosiphon. La contrainte principale qui a guidée cette conception était le fait que la boucle doit refroidir l'armoire et assurer une température d'air à l'entrée des équipements inférieure à la limite imposée par la norme ETSI. Ceci nous a mené à concevoir un prototype de boucle thermosiphon dont la puissance thermique qu'il doit dissiper est imposée. On a montré que ce prototype permet de dissiper des puissances thermiques allant jusqu'à 470 W en utilisant une petite charge de npentane. Nous avons effectué des essais sur le refroidissement du prototype d'armoire de télécommunication en utilisant la boucle thermosiphon légèrement modifiée. On montre que les performances thermiques obtenues en utilisant un mode de refroidissement en boucle thermosiphon sont meilleures. Les boucles thermosiphons semblent intéressantes pour un refroidissement passif de matériels déployés dans un réseau de télécommunication...