• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • 11
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 33
  • 33
  • 9
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

EVALUATING POTENTIAL EXPOSURE TO HEXAVALENT CHROMIUM (Cr(VI) AMONG MAINTENANCE MECHANIC WELDERS

PENNLINE, CARA MARIE 08 October 2007 (has links)
No description available.
2

Adsorpční procesy Cr(VI) v syntetické směsi půdních minerálů / Cr(VI) adsorption to synthetic mixture of soil minerals

Pehová, Edita January 2016 (has links)
Due to its toxicity, the Cr(VI) is known as a substance with negative effects on the environment. Understanding of Cr mobility, speciation and its toxicity helps to prevent negative impacts of this contaminant in soils, natural waters and atmosphere. This diploma thesis deals with a mechanism of Cr(VI) adsorption on to mixture of selected soil minerals as quartz, kaolinite and ferrihydrite based on mineralogical and chemical composition of the real contaminated soil. Main goal of diploma thesis is to test the selected surface complexation model, the DLM (diffuse layer model), which could be able to capture the process of Cr(VI) adsorption in natural heterogenic systems like soils. Component additivity approach (CA) was tested. The adsorption experiments were performed with three different concentrations of Cr(VI) (10-4, 10-5, 10-6) as a function of pH at different ionic strengths. Obtained data were used for modelling of adsorption edges and for DLM testing. Results confirmed, that Cr(VI) adsorption in synthetic mixture of enlarged soil minerals, is controlled mainly by presence of Fe-(oxy)hydroxides. The mechanistic surface complexation models used for modelling of Cr(VI) adsorption onto synthetic mineral mixtures, based on real mixed ratios of representative mineral phases in soils, can be useful for prediction of processes responsible for transport and retention of the Cr(VI) in soils.
3

Estudo da adsorção de cromo hexavalente em altas concentrações

Oliveira, Renata Farias January 2013 (has links)
A preocupação com a contaminação dos recursos hídricos proveniente do lançamento de efluentes industriais contendo metais pesados, como o cromo hexavalente, é crescente devido a sua toxicidade agregada. Neste contexto, o desenvolvimento de processos de tratamento de efluentes com viabilidade técnica é fundamental. Assim, o objetivo do presente trabalho consiste em avaliar a técnica de adsorção aplicada à remoção de Cr (VI) em batelada com efluente sintético e industrial e, posteriormente, em coluna de leito fixo. Para isso, foi avaliada a eficiência de diferentes sólidos sorventes na remoção de cromo hexavalente via adsorção. Foram realizados ensaios em batelada com efluente sintético contendo 5 mg.L-1 de Cr (VI) variando o pH de 2 a 6 em 30 minutos. O sólido escolhido para continuação dos ensaios foi carvão ativado granular. Com a finalidade de estudar os parâmetros ótimos de processo, a concentração de sólido adsorvente e o tempo de agitação também foram testados em solução aquosa com 20 mg.L-1 de Cr (VI), em concentração de sólido entre 2,5 e 15 g.L-1 e tempo de contato entre 3 e 180 minutos. A concentração de sólido adsorvente com maior eficiência de remoção foi de 10 g.L-1 e tempo de contato de 50 minutos. O modelo de isoterma de adsorção que melhor se ajustou aos dados experimentais foi o modelo da isoterma de Freundlich. Para os ensaios com efluente real, as condições que se obteve melhores resultados foi em pH sem ajuste e 40 g.L-1 de concentração de carvão ativado. Os testes de adsorção em coluna de leito fixo foram realizados para preavaliar a possibilidade de utilizar este sistema como alternativa de remoção de Cr (VI) para aplicação em estação de tratamento de efluentes de indústria galvânica. Foi avaliado o tempo de ruptura, sendo analisadas as concentrações de Cr (VI) residuais na corrente de saída da planta de adsorção. Os ensaios de adsorção em batelada serviram como base para estes experimentos. Para a condição inicial de pH 2, massa de 5 g de carvão ativado, concentração inicial de Cr (VI) da corrente de alimentação de 100 mg.L-1 e vazão de 20 mL.min-1, o tempo de saturação foi de aproximadamente 135 minutos para o Ensaio 1 e de 150 minutos para o Ensaio 2. A máxima remoção foi de 92,6 %. / The concern about the contamination of water resources from the release of industrial effluents containing heavy metals such as hexavalent chromium, is increasing due to its toxicity aggregate. In this context , the development of wastewater treatment processes with technical feasibility is critical. Hence, the objective of this study is to evaluate the adsorption efficiency technique applied on removal of Cr (VI) in batch with synthetic and industrial wastewater, and later in fixed-bed column. Sorption experiments were carried out with different sorbents aiming to find the best solid for hexavalent chromium removal. Experimental conditions were: 5 mg.L- 1 of Cr (VI), pH between 2 and 6 and 30 minutes of residence time. Activated carbon was chosen for further studies. Process parameters were studied in aqueous solution with 20 mg.L-1 of Cr (VI), 2.5 and 15 g.L-1 concentration of sorbent, 3 and 180 minutes contact time and pH 2 and 10 were also tested. The concentration of adsorbent with higher removal efficiency was 10 g.L-1 and contact time of 50 minutes. The adsorption isotherm model that showed best fit to the experimental data was the model of Freundlich. For assays with industrial effluent, the best conditions were unadjusted pH and 40 g.L-1 concentration of activated carbon. Experiments using fixed bed column were conducted to preview the possibility of using this system as an alternative to galvanic industry. It was evaluated the rupture time and analyzed the concentrations of residual Cr (VI) output current plant adsorption. The batch adsorption experiments were the basis for these experiments. For the initial condition of pH 2, mass of 5 g of activated carbon, the initial concentration of Cr (VI) feed stream 100 mg.L-1 and a flow rate of 20 mL.min-1 rupture time was approximately 135 minutes for Assay 1 and 150 minutes for Assay 2. The maximum removal was 92.6 %.
4

Hexavalent Chromium Removal Using Ultraviolet Photocatalytic Reactor

January 2013 (has links)
abstract: Hexavalant chromium (Cr(VI)) poses an emerging concern in drinking water treatment with stricter regulations on the horizon. Photocatalytic reduction of Cr(VI) was investigated as an engineering scale option to remove hexavalent chromium from drinking or industrial waters via a UV/titanium dioxide (TiO2) process. Using an integrated UV lamp/ceramic membrane system to recirculate TiO2, both hexavalent and total chromium levels were reduced through photocatalytic processes without additional chemicals. Cr(VI) removal increased as a function of higher energy input and TiO2 dosage, achieving above 90% removal for a 1g/L dose of TiO2. Surface analysis of effluent TiO2 confirmed the presence of chromium species. / Dissertation/Thesis / M.S. Engineering 2013
5

Estudo da adsorção de cromo hexavalente em altas concentrações

Oliveira, Renata Farias January 2013 (has links)
A preocupação com a contaminação dos recursos hídricos proveniente do lançamento de efluentes industriais contendo metais pesados, como o cromo hexavalente, é crescente devido a sua toxicidade agregada. Neste contexto, o desenvolvimento de processos de tratamento de efluentes com viabilidade técnica é fundamental. Assim, o objetivo do presente trabalho consiste em avaliar a técnica de adsorção aplicada à remoção de Cr (VI) em batelada com efluente sintético e industrial e, posteriormente, em coluna de leito fixo. Para isso, foi avaliada a eficiência de diferentes sólidos sorventes na remoção de cromo hexavalente via adsorção. Foram realizados ensaios em batelada com efluente sintético contendo 5 mg.L-1 de Cr (VI) variando o pH de 2 a 6 em 30 minutos. O sólido escolhido para continuação dos ensaios foi carvão ativado granular. Com a finalidade de estudar os parâmetros ótimos de processo, a concentração de sólido adsorvente e o tempo de agitação também foram testados em solução aquosa com 20 mg.L-1 de Cr (VI), em concentração de sólido entre 2,5 e 15 g.L-1 e tempo de contato entre 3 e 180 minutos. A concentração de sólido adsorvente com maior eficiência de remoção foi de 10 g.L-1 e tempo de contato de 50 minutos. O modelo de isoterma de adsorção que melhor se ajustou aos dados experimentais foi o modelo da isoterma de Freundlich. Para os ensaios com efluente real, as condições que se obteve melhores resultados foi em pH sem ajuste e 40 g.L-1 de concentração de carvão ativado. Os testes de adsorção em coluna de leito fixo foram realizados para preavaliar a possibilidade de utilizar este sistema como alternativa de remoção de Cr (VI) para aplicação em estação de tratamento de efluentes de indústria galvânica. Foi avaliado o tempo de ruptura, sendo analisadas as concentrações de Cr (VI) residuais na corrente de saída da planta de adsorção. Os ensaios de adsorção em batelada serviram como base para estes experimentos. Para a condição inicial de pH 2, massa de 5 g de carvão ativado, concentração inicial de Cr (VI) da corrente de alimentação de 100 mg.L-1 e vazão de 20 mL.min-1, o tempo de saturação foi de aproximadamente 135 minutos para o Ensaio 1 e de 150 minutos para o Ensaio 2. A máxima remoção foi de 92,6 %. / The concern about the contamination of water resources from the release of industrial effluents containing heavy metals such as hexavalent chromium, is increasing due to its toxicity aggregate. In this context , the development of wastewater treatment processes with technical feasibility is critical. Hence, the objective of this study is to evaluate the adsorption efficiency technique applied on removal of Cr (VI) in batch with synthetic and industrial wastewater, and later in fixed-bed column. Sorption experiments were carried out with different sorbents aiming to find the best solid for hexavalent chromium removal. Experimental conditions were: 5 mg.L- 1 of Cr (VI), pH between 2 and 6 and 30 minutes of residence time. Activated carbon was chosen for further studies. Process parameters were studied in aqueous solution with 20 mg.L-1 of Cr (VI), 2.5 and 15 g.L-1 concentration of sorbent, 3 and 180 minutes contact time and pH 2 and 10 were also tested. The concentration of adsorbent with higher removal efficiency was 10 g.L-1 and contact time of 50 minutes. The adsorption isotherm model that showed best fit to the experimental data was the model of Freundlich. For assays with industrial effluent, the best conditions were unadjusted pH and 40 g.L-1 concentration of activated carbon. Experiments using fixed bed column were conducted to preview the possibility of using this system as an alternative to galvanic industry. It was evaluated the rupture time and analyzed the concentrations of residual Cr (VI) output current plant adsorption. The batch adsorption experiments were the basis for these experiments. For the initial condition of pH 2, mass of 5 g of activated carbon, the initial concentration of Cr (VI) feed stream 100 mg.L-1 and a flow rate of 20 mL.min-1 rupture time was approximately 135 minutes for Assay 1 and 150 minutes for Assay 2. The maximum removal was 92.6 %.
6

Estudo da adsorção de cromo hexavalente em altas concentrações

Oliveira, Renata Farias January 2013 (has links)
A preocupação com a contaminação dos recursos hídricos proveniente do lançamento de efluentes industriais contendo metais pesados, como o cromo hexavalente, é crescente devido a sua toxicidade agregada. Neste contexto, o desenvolvimento de processos de tratamento de efluentes com viabilidade técnica é fundamental. Assim, o objetivo do presente trabalho consiste em avaliar a técnica de adsorção aplicada à remoção de Cr (VI) em batelada com efluente sintético e industrial e, posteriormente, em coluna de leito fixo. Para isso, foi avaliada a eficiência de diferentes sólidos sorventes na remoção de cromo hexavalente via adsorção. Foram realizados ensaios em batelada com efluente sintético contendo 5 mg.L-1 de Cr (VI) variando o pH de 2 a 6 em 30 minutos. O sólido escolhido para continuação dos ensaios foi carvão ativado granular. Com a finalidade de estudar os parâmetros ótimos de processo, a concentração de sólido adsorvente e o tempo de agitação também foram testados em solução aquosa com 20 mg.L-1 de Cr (VI), em concentração de sólido entre 2,5 e 15 g.L-1 e tempo de contato entre 3 e 180 minutos. A concentração de sólido adsorvente com maior eficiência de remoção foi de 10 g.L-1 e tempo de contato de 50 minutos. O modelo de isoterma de adsorção que melhor se ajustou aos dados experimentais foi o modelo da isoterma de Freundlich. Para os ensaios com efluente real, as condições que se obteve melhores resultados foi em pH sem ajuste e 40 g.L-1 de concentração de carvão ativado. Os testes de adsorção em coluna de leito fixo foram realizados para preavaliar a possibilidade de utilizar este sistema como alternativa de remoção de Cr (VI) para aplicação em estação de tratamento de efluentes de indústria galvânica. Foi avaliado o tempo de ruptura, sendo analisadas as concentrações de Cr (VI) residuais na corrente de saída da planta de adsorção. Os ensaios de adsorção em batelada serviram como base para estes experimentos. Para a condição inicial de pH 2, massa de 5 g de carvão ativado, concentração inicial de Cr (VI) da corrente de alimentação de 100 mg.L-1 e vazão de 20 mL.min-1, o tempo de saturação foi de aproximadamente 135 minutos para o Ensaio 1 e de 150 minutos para o Ensaio 2. A máxima remoção foi de 92,6 %. / The concern about the contamination of water resources from the release of industrial effluents containing heavy metals such as hexavalent chromium, is increasing due to its toxicity aggregate. In this context , the development of wastewater treatment processes with technical feasibility is critical. Hence, the objective of this study is to evaluate the adsorption efficiency technique applied on removal of Cr (VI) in batch with synthetic and industrial wastewater, and later in fixed-bed column. Sorption experiments were carried out with different sorbents aiming to find the best solid for hexavalent chromium removal. Experimental conditions were: 5 mg.L- 1 of Cr (VI), pH between 2 and 6 and 30 minutes of residence time. Activated carbon was chosen for further studies. Process parameters were studied in aqueous solution with 20 mg.L-1 of Cr (VI), 2.5 and 15 g.L-1 concentration of sorbent, 3 and 180 minutes contact time and pH 2 and 10 were also tested. The concentration of adsorbent with higher removal efficiency was 10 g.L-1 and contact time of 50 minutes. The adsorption isotherm model that showed best fit to the experimental data was the model of Freundlich. For assays with industrial effluent, the best conditions were unadjusted pH and 40 g.L-1 concentration of activated carbon. Experiments using fixed bed column were conducted to preview the possibility of using this system as an alternative to galvanic industry. It was evaluated the rupture time and analyzed the concentrations of residual Cr (VI) output current plant adsorption. The batch adsorption experiments were the basis for these experiments. For the initial condition of pH 2, mass of 5 g of activated carbon, the initial concentration of Cr (VI) feed stream 100 mg.L-1 and a flow rate of 20 mL.min-1 rupture time was approximately 135 minutes for Assay 1 and 150 minutes for Assay 2. The maximum removal was 92.6 %.
7

Cr(VI) reduction by Fe(II)-dissolved organic matter complexes and the characterization of pore water dissolved organic matter from a coastal wetland in the Laurentian Great Lakes

Agrawal, Sheela G. January 2008 (has links)
No description available.
8

Comportamento de corrosão de camadas isentas de cromo hexavalente e sem enxágue aplicadas sobre superfícies eletrozincadas produzidas em linhas contínuas. / Corrosion behavior of layers free hexavalent chromium no rinse applied on eletrozincs surfaces produced in lines continuing.

Pérez Hernández, Victor Ernesto 15 December 2014 (has links)
A preocupação com o desenvolvimento sustentável tem levado a indústria e os órgãos controladores do meio ambiente a reavaliarem o emprego em larga escala de procedimentos industriais que, embora eficientes, são prejudiciais à saúde humana e ao meio ambiente. Em concordância com estas novas tendências, as indústrias de tratamento de superfícies de metais e instituições de pesquisa têm empregado grandes esforços no sentido de encontrar substitutos eficientes para procedimentos de proteção contra a corrosão que contenham íons de cromo hexavalente, os quais são muito eficientes, mas apresentam o inconveniente de não serem ambientalmente corretos devido ao caráter cancerígeno e poluente do íon Cr(VI) já reconhecido por diversas agências de proteção ambiental. Com a finalidade de aumentar a proteção contra a corrosão, em linhas industriais contínuas de eletrogalvanização por eletrodeposição, as peças produzidas são protegidas por uma camada de passivação obtida em banho de conversão contendo sais de Cr(VI) e, na maioria dos casos, não passa pelo processo de enxágue após sua produção. Neste trabalho o comportamento de corrosão do aço eletrogalvanizado protegido com camadas de passivação obtidas a partir de banhos de conversão contendo sais de Cr(III) e Co(II) ou uma emulsão de um copolímero de etileno, sem enxágue, foi avaliado por técnicas eletroquímicas, especificamente, acompanhamento do potencial de circuito aberto, curvas de polarização potenciodinâmica anódicas e catódicas, e espectroscopia de impedância eletroquímica (EIS), em soluções com diferentes concentrações de NaCl. Adicionalmente foi avaliado o comportamento de corrosão por ensaios em câmara de névoa salina, realizados de acordo com a norma ASTM B117-11. Como referência, os resultados foram comparados com aqueles apresentados por amostras protegidas por camada de passivação produzida a partir de banho contendo íons de Cr(VI). Para melhor compreender a influência da microestrutura sobre o mecanismo de corrosão, as amostras foram caracterizadas por microscopia eletrônica de varredura antes e após imersão nos diferentes eletrólitos. A análise microestrutural foi complementada por ensaios de difração de raios-X. 7 Os resultados dos ensaios eletroquímicos realizados após tempos curtos de imersão mostraram melhor desempenho para as amostras protegidas com a camada de passivação produzida a partir de banho contendo íons Cr(VI). Entretanto os ensaios de EIS após tempos mais longos de imersão nos diferentes eletrólitos ensaio, bem como os ensaios de névoa, evidenciaram que as amostras protegidas com a camada passiva obtida a partir do banho contendo íons de Cr(III) e Co(II) podem apresentar desempenho semelhante àquelas protegidas com camada de conversão de Cr(VI). Para esta condição, a análise microestrutural e o ajuste dos diagramas de EIS com circuitos equivalentes indicaram um papel importante dos produtos de corrosão no comportamento anticorrosivo das amostras protegidas com a camada de passivação de Cr(III) e Co(II). Em nenhuma das condições estudadas as amostras protegidas com o copolímero de etileno apresentaram desempenhos comparáveis aos das outras duas camadas de passivação estudadas. / Recent concerns with sustainable development have led industries and environment regulatory agencies to reassess the use at large scale of industrial procedures that, although efficient, are harmful to human health and the environment. In accordance with these new tendencies, surface treatment industries and research institutes have expended great efforts to find efficient substitutes for corrosion protection procedures that employ hexavalent chromium ions (Cr(VI)). They are very effective but have the drawback of not being environmentally friendly due to the carcinogenic and pollutant properties of Cr(VI) ions, already recognized by several environmental protection agencies. Aiming to increase the corrosion protection, in industrial continuous lines of galvanizing by electroplating, the parts produced are protected with a passivation layer obtained from a conversion bath containing Cr(VI). These parts are not rinsed after the final production step. In this work the corrosion behavior of electroplated galvanized steel protected with passivation layers from conversion baths containing Cr(III) and Co(II) ions or an ethylene copolymer emulsion was evaluated by means of electrochemical techniques, specifically, open circuit potential measurements, anodic and cathodic potentiodynamic polarization curves and electrochemical impedance spectroscopy (EIS). The tests were performed in sodium chloride solutions of different concentrations. Additionally, the corrosion behavior was evaluated by salt spray tests performed according the ASTM B117-11 standard. For reference, the results were compared with those presented by samples protected by passivation layers produced from conversion baths containing Cr (VI) ions. Aiming to better understand the influence of microstructure on the corrosion mechanism, the samples were characterized by scanning electron microscopy before and after immersion in the different electrolytes. Microstructure analysis was complemented by X-ray diffraction. The results of electrochemical tests performed after short immersion times showed better corrosion performance for samples protected with the passivation layer produced from conversion baths containing Cr(VI) ions. However, the EIS tests performed after longer immersion times in the different electrolytes, as well as the 9 salt spray tests, showed that samples protected with the passive layer obtained from the bath containing Cr (III) and Co (II) ions may present similar performance to those protected with the Cr (VI) conversion layer. The microstructural analysis and fitting of the EIS diagrams with equivalent circuits indicated an important role of corrosion products in the anti-corrosive performance of the samples protected with the passivation layer of Cr (III) and Co (II). In the studied conditions, the samples protected with the ethylene copolymer did not showed comparable performance to the other two passivation layers investigated in the present study.
9

Fotocatálise heterogênea no polimento de efluentes sintéticos de curtume: alternativa para minimizar impactos ambientais

Pascoal, Salomão de Andrade 23 February 2006 (has links)
Made available in DSpace on 2015-05-07T14:49:30Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 971027 bytes, checksum: d7b9e301ff511c4ffe34d7076926030e (MD5) Previous issue date: 2006-02-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The industry is a section of the contemporary society with great pollutant potential of the environment, especially of the aquatic ecosystems. The tanning industries are big producing of dejections with significant amounts of organic matter and of chrome. The conventional processes of treatment applied those dejections, not always they possess good effectiveness. Actuality, the Advanced Oxidation Processes represent an excellent alternative of tertiary treatment. In the present study, the application of the heterogeneous photocatalysis was evaluated, being used a photocatalyst (TiO2) immobilized, in the tertiary treatment of synthetic liquid effluents representative of tanning industries. It was aimed at to remove Cr(VI) and organic matter. The photocatalytic reactor was of the type Fixed Bed of Fine Film, built with a plate of glass arrayed for the fixation of TiO2. It was adopted as radiation sources, the sun and lamps issuing of UV radiation (λ= 250 nm). The smallest values of removal effectiveness for Cr(VI) they were of 62% and 51% and of DOC they were from 60% and 53% to the experiments done with radiation UV originating from of the sun and of lamps, respectively. The results of the parameters related to the reduction phases and oxidation of the heterogeneous photocatalysis, they showed that the exhibition in the sun, he/she has effectiveness of larger relative removal than the exhibition to UV lamps. The data of relative removal of Cr(VI) and of DOC and the constants kinetics of these parameters, they indicated that the adopted experimental configurations optimized the phase of reduction of the heterogeneous photocatalysis. / A indústria é um setor da sociedade contemporânea com grande potencial poluidor do meio ambiente, especialmente dos ecossistemas aquáticos. As indústrias de curtume são grandes produtoras de dejetos com significativas quantidades de material orgânico e de cromo. Os processos convencionais de tratamento aplicados a esses dejetos, nem sempre possuem boa eficácia. Atualmente, os Processos Oxidativos Avançados representam uma excelente alternativa de tratamento terciário. No presente estudo, avaliou-se a aplicação da fotocatálise heterogênea, usando-se um fotocatalisador (TiO2) imobilizado, no tratamento final de efluentes líquidos sintéticos representativos de indústrias de curtume. Objetivou-se remover Cr(VI) e matéria orgânica. O fotorreator foi do tipo Leito Fixo de Filme Fino, construído com uma placa de vidro jateado para a fixação do TiO2. Adotou-se como fontes de radiação, o sol e lâmpadas germicidas emissoras de radiação UV (λ= 250 nm). Os menores valores de eficácia de remoção para Cr(VI) foram de 62% e 51% e de DQO foram de 60% e 53% para os experimentos feitos com radiação UV oriundas do sol e de lâmpadas, respectivamente. Os resultados dos parâmetros relacionados às fases de redução e oxidação da fotocatálise heterogênea, mostraram que a exposição ao sol, tem eficácia de remoção relativa maior do que a exposição à lâmpadas UV. Os dados de remoção relativa de Cr(VI) e de DQO e as constantes cinéticas destes parâmetros, indicaram que as configurações experimentais adotadas otimizaram a fase de redução da fotocatálise heterogênea.
10

Utilização de escamas do peixe corvina para adsorção de Cr(VI) em meio aquoso - cinética e termodinâmica por calorimetria isotérmica contínua

Moura, Karine Oliveira 18 February 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Adsorption has become a key process for the removal of very low amounts of undesirable components from waters and wastewaters and in the sense for being environmental friendly as well. This work has as aim the study of some properties of scales of Corvina fish (Micropogonias furnieiri) as a new adsorbent to remove Cr(VI) from aqueous solutions. The Corvina scales were characterized by thermogravimetry, Fourier transformed infrared spectroscopy, scanning electron microscopy with energydispersive electron probe X-ray analysis, X-ray diffraction and pH of point of zero charge. The characterization results have suggested that the Corvina scales present two main structural phases, one being rich in type I collagen and one rich in apatites. Sorption studies of Cr(VI) using the batch methodology have indicated that Cr(VI) sorption increased when both initial Cr(VI) concentration in solution and temperature increase. Calorimetric measurements of scales water wetting have pointed out slightly exothermic results and degrees of wetting from 30.8 to 45.3 %. The kinetic data of Cr(VI) sorption were best fitted to the Avrami exponential model. The equilibrium data of Cr(VI) sorption were best fitted to both the Langmuir-Freundlich and the Sips models. Indirect thermodynamic determinations have indicated that the sorption of Cr(VI) is endothermic (ΔH = 31,21 kJ mol-1), spontaneous (ΔG < 0), with positive entropies (ΔS = 0,14 kJ mol-1 K-1). Calorimetric measurements have suggested that the interactions of Cr (VI) with the surface sorption sites of Corvina scales are exothermic in nature. It also was found that the presence of an anionic surfactant can increase Cr(VI) sorption on Corvina scales due to a dynamic equilibrium between monomers and micelles. The initial analysis of Cr(VI) desorption from Corvina scales has shown the release of about 30% of sorbed chromium in alkaline medium. It has been noted that the scales of Corvina fish present important characteristics to be used as a new adsorbent for removal of Cr(VI) from aqueous solutions. / A sorção tem se tornado um método muito atrativo, pois permite extrair compostos tóxicos em níveis muito baixos e não gerar subprodutos tóxicos em efluentes aquosos. O presente trabalho avaliou a utilização de escamas de peixe Corvina (Micropogonias furnieri) como um novo adsorvente para remoção do Cr(VI) de soluções aquosas. As escamas foram caracterizadas por termogravimetria, espectroscopia na região do infravermelho, microscopia eletrônica de varredura com medidas de energia dispersiva, difratometria de raios-X e determinação do pH do ponto de carga zero. Os resultados indicaram que as escamas são formadas, predominantemente, de uma fase orgânica rica em colágeno tipo I e outra rica em apatitas. Testes calorimétricos de molhação das escamas apontaram energias de molhação exotérmicas e graus de molhação entre 30,8-45,3%. Estudos cinéticos mostraram aumento da capacidade de remoção das escamas com o aumento da concentração inicial de Cr(VI) em solução e da temperatura. Estudos de cinética de sorção de Cr(VI) por batelada e por calorimetria em solução apontaram melhores ajustes matemáticos utilizando-se o modelo exponencial de Avrami. Estudos de sorção no equilíbrio indicaram melhor ajustes aos modelos de Langmuir-Freundlich e Sips. Determinações termodinâmicas indiretas indicaram que os processos de sorção são endotérmicos (ΔH = 31,21 kJ mol-1), espontâneos (ΔG < 0), e com aumento de entropia após os processos de sorção (ΔS = 0,14 kJ mol-1 K-1). Medidas calorimétricas em solução indicaram que as interações de Cr(VI) com os sítios de sorção mais externos são processos exotérmicos. A presença de surfactante aniônico na solução de Cr(VI) pode aumentar a sorção de Cr(VI) pelas escamas devido a um equilíbrio dinâmico entre monômeros e micelas. Testes iniciais de dessorção de Cr(VI) indicaram liberação de cerca de 30% do crômio sorvido, em meio básico. Observou-se que as escamas de Corvina apresentam excelentes perspectivas como um novo material para remoção de Cr(VI) de soluções aquosas.

Page generated in 0.0326 seconds