1

Localização de faltas em alimentadores de distribuição de energia elétrica usando medições esparsas de tensões /

Pereira, Rodrigo Aparecido Fernandes. January 2007 (has links)
Orientador: José Roberto Sanches Mantovani / Banca: Antonio Padilha Feltrin / Banca: Rubén Augusto Romero Lázaro / Banca: Denis Vinicius Coury / Banca: Walmir de Freitas Filho / Resumo: Neste trabalho, é proposto um algoritmo para localização de faltas em alimentadores radiais aéreos de distribuição de energia elétrica. A técnica proposta aplica-se a alimentadores trifásicos com cargas desequilibradas, que podem possuir ramais laterais trifásicos, bifásicos e monofásicos. As equações da rede que compõem esta técnica foram desenvolvidas com base nos métodos de fluxo de potência do tipo varredura (backward/forward sweep), o que a torna uma ferramenta eficiente e de baixo esforço computacional. No desenvolvimento da mesma, considera-se que haja disponibilidade de medições de tensões no nó inicial do alimentador e também medições esparsas de tensão em alguns pontos ao longo do alimentador de distribuição. Esta técnica apresenta algumas vantagens quando comparada com as técnicas convencionais para localização de faltas que utilizam o deslocamento do local da falta na rede. Nela eliminam-se, dos possíveis locais de falta, os pontos que estão em ramais laterais geograficamente distantes do verdadeiro local da falta e que poderiam ser indicados pelos métodos convencionais de localização da faltas. Adicionalmente à técnica para localização de faltas, é proposto um modelo matemático de programação binária para fazer a alocação otimizada de medidores esparsos de tensões ao longo do alimentador com o propósito de melhorar a precisão do algoritmo desenvolvido, a partir da técnica proposta para a localização de faltas. Neste modelo matemático, busca-se manter a melhor relação custo-benefício para as empresas de energia, em termos de investimentos, custos operacionais e melhorias dos seus índices de confiabilidade, com a localização eficiente de faltas em suas redes de distribuição. Para a solução deste modelo matemático, propõe-se... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: An algorithm for fault location on overhead and radial electric power distribution feeders is proposed in this work. The proposed technique is able to be applied to three-phase feeders containing unbalanced loads. Also, the proposed technique has the ability to deal with feeders which has three-, two- or single-phase laterals. Equations that describe the network are derived based on the backward/forward sweep load flow methods. This characteristic makes the proposed fault location technique an efficient and fast computational tool. In order to develop this technique, it was considered that voltage measurements are available at the sending node of the feeder, as well sparse voltage measurements at some places on the feeder. Thus, this technique presents some advantages in comparison to the traditional technique for fault location which finds the faulty point by means of sliding the analyzed point on the network. By using traditional techniques, points located geographically far from the actual faulty point can be indicated as a faulty point. The proposed technique eliminates these points from the results. Additionally to the proposed technique, a binary programming model is presented for carrying out the optimized placement of voltage measurement devices along the feeder. The goal of this binary programming model is to enhance the accuracy of the proposed algorithm for fault location. This mathematical model is aimed at keeping the best costbenefit rate for the electric utilities, in terms of operational costs and improvements of reliability indices by means of an efficient fault location. A dedicated genetic algorithm is proposed for solving the optimization model. Results and simulation analyses are presented in order to validate the efficiency... (Complete abstract click electronic access below) / Doutor
2

Localização de faltas em alimentadores de distribuição de energia elétrica usando medições esparsas de tensões

Pereira, Rodrigo Aparecido Fernandes [UNESP] 02 March 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:52Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-03-02Bitstream added on 2014-06-13T19:40:20Z : No. of bitstreams: 1 pereira_raf_dr_ilha.pdf: 1085197 bytes, checksum: 8d25137a551ef06a95af7c5112ebbaf6 (MD5) / Fundação de Ensino Pesquisa e Extensão de Ilha Solteira (FEPISA) / Neste trabalho, é proposto um algoritmo para localização de faltas em alimentadores radiais aéreos de distribuição de energia elétrica. A técnica proposta aplica-se a alimentadores trifásicos com cargas desequilibradas, que podem possuir ramais laterais trifásicos, bifásicos e monofásicos. As equações da rede que compõem esta técnica foram desenvolvidas com base nos métodos de fluxo de potência do tipo varredura (backward/forward sweep), o que a torna uma ferramenta eficiente e de baixo esforço computacional. No desenvolvimento da mesma, considera-se que haja disponibilidade de medições de tensões no nó inicial do alimentador e também medições esparsas de tensão em alguns pontos ao longo do alimentador de distribuição. Esta técnica apresenta algumas vantagens quando comparada com as técnicas convencionais para localização de faltas que utilizam o deslocamento do local da falta na rede. Nela eliminam-se, dos possíveis locais de falta, os pontos que estão em ramais laterais geograficamente distantes do verdadeiro local da falta e que poderiam ser indicados pelos métodos convencionais de localização da faltas. Adicionalmente à técnica para localização de faltas, é proposto um modelo matemático de programação binária para fazer a alocação otimizada de medidores esparsos de tensões ao longo do alimentador com o propósito de melhorar a precisão do algoritmo desenvolvido, a partir da técnica proposta para a localização de faltas. Neste modelo matemático, busca-se manter a melhor relação custo-benefício para as empresas de energia, em termos de investimentos, custos operacionais e melhorias dos seus índices de confiabilidade, com a localização eficiente de faltas em suas redes de distribuição. Para a solução deste modelo matemático, propõe-se... / An algorithm for fault location on overhead and radial electric power distribution feeders is proposed in this work. The proposed technique is able to be applied to three-phase feeders containing unbalanced loads. Also, the proposed technique has the ability to deal with feeders which has three-, two- or single-phase laterals. Equations that describe the network are derived based on the backward/forward sweep load flow methods. This characteristic makes the proposed fault location technique an efficient and fast computational tool. In order to develop this technique, it was considered that voltage measurements are available at the sending node of the feeder, as well sparse voltage measurements at some places on the feeder. Thus, this technique presents some advantages in comparison to the traditional technique for fault location which finds the faulty point by means of sliding the analyzed point on the network. By using traditional techniques, points located geographically far from the actual faulty point can be indicated as a faulty point. The proposed technique eliminates these points from the results. Additionally to the proposed technique, a binary programming model is presented for carrying out the optimized placement of voltage measurement devices along the feeder. The goal of this binary programming model is to enhance the accuracy of the proposed algorithm for fault location. This mathematical model is aimed at keeping the best costbenefit rate for the electric utilities, in terms of operational costs and improvements of reliability indices by means of an efficient fault location. A dedicated genetic algorithm is proposed for solving the optimization model. Results and simulation analyses are presented in order to validate the efficiency... (Complete abstract click electronic access below)
3

Modelo estocástico de programação matemática de alocação de medidores de tensão em alimentadores radiais de distribuição de energia elétrica para localização de faltas e monitoramento do perfil de tensão

Bíscaro, André do Amaral Penteado [UNESP] 18 February 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-02-18Bitstream added on 2014-06-13T18:49:30Z : No. of bitstreams: 1 biscaro_aap_me_ilha.pdf: 1057545 bytes, checksum: feb928c10ad58cb9fc7bef33003e6afc (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Neste trabalho é proposta uma técnica de otimização para alocar medidores dispersos de tensão em alimentadores radiais aéreos de distribuição baseada na metaheurística Greedy Randomized Adaptive Search Procedure (GRASP), com o objetivo de melhorar o desempenho de algoritmos de localização de faltas que utilizam informações esparsas de tensão e, simultaneamente, fazer o controle em tempo real do nível de tensão do alimentador operando sob diferentes cenários. No modelo de programação proposto para alocar os medidores considera-se a natureza estocástica das variáveis envolvidas no problema relacionado com o estudo de contingências em sistemas de energia elétrica, ou seja: carregamento dos transformadores da rede no instante de ocorrência da falta, impedância de falta, probabilidade de falhas e erros de medição dos medidores dispersos de tensão, probabilidade de ocorrer qualquer um dos tipos de faltas possíveis, entre outros. O modelo da função objetivo contempla a localização de faltas com boa precisão para qualquer algoritmo que utiliza medições esparsas de tensão e os menores valores de magnitudes de tensão no alimentador, operando em condições normais ou sob contingências. Apresentam-se resultados de testes com a metodologia proposta para dois alimentadores reais de distribuição de energia elétrica. O primeiro alimentador é de médio porte, tensão nominal de 13,8 kV e possui 134 barras. O segundo alimentador é de grande porte, tensão nominal de 11,4 kV e possui 3287 barras. / This work proposes an optimization technique to allocate voltage measurement devices on radial overhead electric power distribution feeders based on Greedy Randomized Adaptive Search Procedure (GRASP) metaheuristic, aiming at improving the performance of algorithms for fault location using sparse voltage information, while making the real time control of the feeder’s operating voltage under different scenarios. The proposed programming model to allocate the devices considers the nature of the stochastic variables involved in the problem with the study of contingencies in electric power systems: loading of the network transformers at time of occurrence of failure, fault impedance, probability of failures and errors of measurement of dispersed voltage devices, likelihood that any of the possible types of faults occur, among others. The model's objective function includes the faults location procedure with good precision for any algorithm that uses sparse measurements of voltage and the lowest values of the magnitudes of voltage feeder, operating under normal conditions or contingencies. Test results with the proposed methodology applied to simulated data of two real life feeders are presented. The first feeder is medium size, rated voltage of 13.8 kV and has 134 bars. The second feeder is large, rated voltage of 11.4 kV and has 3287 bars.
4

Modelo estocástico de programação matemática de alocação de medidores de tensão em alimentadores radiais de distribuição de energia elétrica para localização de faltas e monitoramento do perfil de tensão /

Bíscaro, André do Amaral Penteado. January 2009 (has links)
Orientador: José Roberto Sanches Mantovani / Banca: Jozué Vieira Filho / Banca: Arturo Suman Bretas / Resumo: Neste trabalho é proposta uma técnica de otimização para alocar medidores dispersos de tensão em alimentadores radiais aéreos de distribuição baseada na metaheurística Greedy Randomized Adaptive Search Procedure (GRASP), com o objetivo de melhorar o desempenho de algoritmos de localização de faltas que utilizam informações esparsas de tensão e, simultaneamente, fazer o controle em tempo real do nível de tensão do alimentador operando sob diferentes cenários. No modelo de programação proposto para alocar os medidores considera-se a natureza estocástica das variáveis envolvidas no problema relacionado com o estudo de contingências em sistemas de energia elétrica, ou seja: carregamento dos transformadores da rede no instante de ocorrência da falta, impedância de falta, probabilidade de falhas e erros de medição dos medidores dispersos de tensão, probabilidade de ocorrer qualquer um dos tipos de faltas possíveis, entre outros. O modelo da função objetivo contempla a localização de faltas com boa precisão para qualquer algoritmo que utiliza medições esparsas de tensão e os menores valores de magnitudes de tensão no alimentador, operando em condições normais ou sob contingências. Apresentam-se resultados de testes com a metodologia proposta para dois alimentadores reais de distribuição de energia elétrica. O primeiro alimentador é de médio porte, tensão nominal de 13,8 kV e possui 134 barras. O segundo alimentador é de grande porte, tensão nominal de 11,4 kV e possui 3287 barras. / Abstract: This work proposes an optimization technique to allocate voltage measurement devices on radial overhead electric power distribution feeders based on Greedy Randomized Adaptive Search Procedure (GRASP) metaheuristic, aiming at improving the performance of algorithms for fault location using sparse voltage information, while making the real time control of the feeder's operating voltage under different scenarios. The proposed programming model to allocate the devices considers the nature of the stochastic variables involved in the problem with the study of contingencies in electric power systems: loading of the network transformers at time of occurrence of failure, fault impedance, probability of failures and errors of measurement of dispersed voltage devices, likelihood that any of the possible types of faults occur, among others. The model's objective function includes the faults location procedure with good precision for any algorithm that uses sparse measurements of voltage and the lowest values of the magnitudes of voltage feeder, operating under normal conditions or contingencies. Test results with the proposed methodology applied to simulated data of two real life feeders are presented. The first feeder is medium size, rated voltage of 13.8 kV and has 134 bars. The second feeder is large, rated voltage of 11.4 kV and has 3287 bars. / Mestre