• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Contribution à la modélisation des défauts de bobinages des machines électriques et à leur détection par des mesures au rotor / Contribution à la modélisation des défauts de bobinages des machines électriques et à leur détection par des mesures au rotor

Rouached, Bouali 21 June 2021 (has links)
Ce travail de thèse traite de la détection des défauts de bobinages au stator dans les machines électriques contenant une structure d'amortissement. Les courts-circuits entre spires d'un même enroulement sont souvent la prémisse de l'apparition d'autres défauts de bobinages dont les conséquences sont plus sévères. La précocité de détection est donc essentielle pour préserver les machines et leur environnement humain ou matériel. Dans cet ouvrage, nous proposons une solution innovante de discrimination des courts-circuits basée sur la redondance de signaux mesurés au rotor. Pour définir celle-ci, une modélisation d'ordre élevé combinant l'approche des éléments finis et celle des circuits couplés a été employée. La première est utilisée pour déterminer les paramètres (couplages magnétiques) exploités par la seconde qui n'est autre que le modèle comportemental. Comme l'inconvénient de cette combinaison d'approches est le temps utile à l'identification des couplages magnétiques et sachant que diverses configurations de bobinage doivent être modélisées, une nouvelle méthodologie d'identification a été développée. Après une première identification (éléments finis) à temps réduit, celle-ci offre la possibilité d'estimer les paramètres d'une configuration de bobinage souhaitée sans réutilisation de la résolution par éléments finis. En plus de son exploitation pour mettre en œuvre le procédé de détection présenté, cette méthodologie d'identification est un générateur de paramètres utiles pour des détections basées sur « l'estimation paramétrique ». La modélisation des circuits couplés présente un excellent rapport précision/temps de calcul et une bonne efficacité dans la représentation des phénomènes spatiotemporels. L'intégration d'un défaut de bobinage nécessite de faire évoluer les équations de circuits du modèle. À des fins d'atteindre l'objectif de cette thèse, la structure du modèle a été modifiée pour introduire les courts-circuits entre spires au stator. En dehors de l'application présentée, l'association de la méthode d'identification avec le modèle comportemental permet la reproduction rapide de forme d'onde multiple, notamment exploitable dans les approches de détection orientée « signal ». Enfin, à partir de l'outil résultant des travaux précédents, le procédé de diagnostic a pu être déterminé. La sensibilité de détection est le critère principal pour la définition de la technique instrumentale et des traitements de signaux du procédé. L'influence des conditions de fonctionnement sur la sensibilité de détection est évaluée et est considérée pour le choix des solutions retenues. Ce procédé a été validé expérimentalement sur un alternateur synchrone à rotor bobiné de 5.4KVA. / Ce travail de thèse traite de la détection des défauts de bobinages au stator dans les machines électriques contenant une structure d'amortissement. Les courts-circuits entre spires d'un même enroulement sont souvent la prémisse de l'apparition d'autres défauts de bobinages dont les conséquences sont plus sévères. La précocité de détection est donc essentielle pour préserver les machines et leur environnement humain ou matériel. Dans cet ouvrage, nous proposons une solution innovante de discrimination des courts-circuits basée sur la redondance de signaux mesurés au rotor. Pour définir celle-ci, une modélisation d'ordre élevé combinant l'approche des éléments finis et celle des circuits couplés a été employée. La première est utilisée pour déterminer les paramètres (couplages magnétiques) exploités par la seconde qui n'est autre que le modèle comportemental. Comme l'inconvénient de cette combinaison d'approches est le temps utile à l'identification des couplages magnétiques et sachant que diverses configurations de bobinage doivent être modélisées, une nouvelle méthodologie d'identification a été développée. Après une première identification (éléments finis) à temps réduit, celle-ci offre la possibilité d'estimer les paramètres d'une configuration de bobinage souhaitée sans réutilisation de la résolution par éléments finis. En plus de son exploitation pour mettre en œuvre le procédé de détection présenté, cette méthodologie d'identification est un générateur de paramètres utiles pour des détections basées sur « l'estimation paramétrique ». La modélisation des circuits couplés présente un excellent rapport précision/temps de calcul et une bonne efficacité dans la représentation des phénomènes spatiotemporels. L'intégration d'un défaut de bobinage nécessite de faire évoluer les équations de circuits du modèle. À des fins d'atteindre l'objectif de cette thèse, la structure du modèle a été modifiée pour introduire les courts-circuits entre spires au stator. En dehors de l'application présentée, l'association de la méthode d'identification avec le modèle comportemental permet la reproduction rapide de forme d'onde multiple, notamment exploitable dans les approches de détection orientée « signal ». Enfin, à partir de l'outil résultant des travaux précédents, le procédé de diagnostic a pu être déterminé. La sensibilité de détection est le critère principal pour la définition de la technique instrumentale et des traitements de signaux du procédé. L'influence des conditions de fonctionnement sur la sensibilité de détection est évaluée et est considérée pour le choix des solutions retenues. Ce procédé a été validé expérimentalement sur un alternateur synchrone à rotor bobiné de 5.4KVA. / This thesis deals with the detection of stator winding faults in electrical machines containing a damping structure. Short-circuits between turns of the same winding are often the premise for the appearance of other winding faults, the consequences of which are more severe. Early detection is therefore essential to preserve machines and their human or material environment. In this book, we propose an innovative solution to short-circuit discrimination based on the redundancy of signals measured at the rotor. To define this, high-order modelling combining the finite element approach and that of coupled circuits was used. The first is used to determine the parameters (magnetic couplings) exploited by the second which is none other than the behavioural model. As the downside of this combination of approach is the time taken to identify magnetic couplings and the knowledge that various coil configurations must be modelled, a new identification methodology was developed. After an initial identification (finite elements) at short notice, this offers the possibility of estimating the parameters of a desired winding configuration without reusing the finite element resolution. In addition to its use to implement the detection method presented, this identification methodology is a generator of useful parameters for detections based on "parametric estimation". The modelling of coupled circuits presents an excellent precision / calculation time ratio and a good efficiency in the representation of spatial-temporal phenomena. Integrating a winding fault requires changing the model's circuit equations. In order to achieve the objective of this thesis, the structure of the model has been modified to introduce the short circuits between turns at the stator. Apart from the application presented, the association of the identification method with the behavioural model allows the rapid production of multiple waveforms, particularly usable in "signal" oriented detection approaches. Finally, from the tool resulting from the previous work, the diagnostic process could be determined. The detection sensitivity is the main criterion for the definition of the instrumental technique and the signal processing of the process. The influence of the operating conditions on the detection sensitivity is evaluated and is considered for the choice of the solutions adopted. This process has been validated experimentally on a synchronous alternator with wound rotor of 5.4KVA. / This thesis deals with the detection of stator winding faults in electrical machines containing a damping structure. Short-circuits between turns of the same winding are often the premise for the appearance of other winding faults, the consequences of which are more severe. Early detection is therefore essential to preserve machines and their human or material environment. In this book, we propose an innovative solution to short-circuit discrimination based on the redundancy of signals measured at the rotor. To define this, high-order modelling combining the finite element approach and that of coupled circuits was used. The first is used to determine the parameters (magnetic couplings) exploited by the second which is none other than the behavioural model. As the downside of this combination of approach is the time taken to identify magnetic couplings and the knowledge that various coil configurations must be modelled, a new identification methodology was developed. After an initial identification (finite elements) at short notice, this offers the possibility of estimating the parameters of a desired winding configuration without reusing the finite element resolution. In addition to its use to implement the detection method presented, this identification methodology is a generator of useful parameters for detections based on "parametric estimation". The modelling of coupled circuits presents an excellent precision / calculation time ratio and a good efficiency in the representation of spatial-temporal phenomena. Integrating a winding fault requires changing the model's circuit equations. In order to achieve the objective of this thesis, the structure of the model has been modified to introduce the short circuits between turns at the stator. Apart from the application presented, the association of the identification method with the behavioural model allows the rapid production of multiple waveforms, particularly usable in "signal" oriented detection approaches. Finally, from the tool resulting from the previous work, the diagnostic process could be determined. The detection sensitivity is the main criterion for the definition of the instrumental technique and the signal processing of the process. The influence of the operating conditions on the detection sensitivity is evaluated and is considered for the choice of the solutions adopted. This process has been validated experimentally on a synchronous alternator with wound rotor of 5.4KVA.
2

Développement d'algorithmes de détection de défauts pour la maintenance prédictive de générateurs hydroélectriques

Cyr, Charles 11 April 2018 (has links)
Les arrêts de production dus à des défauts de l'équipement sont coûteux dans les centrales hydroélectriques. Ces arrêts peuvent être causés par un mauvais asservissement de la vitesse des générateurs. L'utilisation d'un système de monitoring des performances de régulation permet de connaître à intervalle rapproché l'état de l'asservissement de vitesse des générateurs. Les méthodes de détection de défauts développées et appliquées aux générateurs déterminent la probabilité d'occurrence d'un arrêt de production engendré par une instabilité. L'utilisation des méthodes classiques de supervision des procédés intégrées à l'aide de l'analyse par composantes principales permet d'obtenir une détection et une localisation des défauts présents dans les régulateurs et les générateurs hydroélectriques. Les résultats obtenus sont présentés sous forme de graphiques aisément interprétables.
3

Single phase to ground fault detection and location in compensated network

Loos, Matthieu 05 November 2013 (has links)
This work takes place in the context of distribution power system protection and tries to improve the detection and location of earth faults. The protection problem is vast and many ideas emerge every year to enhance the reliability of the grid. The author has focused his energy into the compensated and isolated network protection in the specific case of single phase earth fault. This PhD thesis is divided in two main parts that might be considered as independent. The first part studies the detection of single phase earth fault and the second analyzes the fault location of such fault.<p><p>Pragmatism was asked during these three years because a product development was necessary especially regarding the fault detection problem. The first part of the thesis took 18 months of research and development to obtain a prototype of transient protection able to detect single phase earth fault in compensated and isolated network. The sensitivity of the algorithm has been emphasized regarding the fault impedance and to detect earth fault up to 5 kOhm depending on the network characteristic. The fault location problem has been much more theoretical although the problem links to the accuracy of the algorithm and its robustness regarding wrong fault location indication has been strongly considered.<p><p>Compensated networks and in some conditions isolated networks are distribution from 12 kV up to 110 kV mostly used in East and North Europe but also in China. Others areas also work with such networks but they also have others systems and they do not use them on all the territory. These networks have the particularity to obtain very small fault current in case of single phase earth fault. Low current means the difference between a faulty and a sound feeder is not significant. Therefore classic overcurrent protection is completely useless to protect the network, forcing the development of more complex algorithm. A possibility to overcome the problem of the small fault current is to develop a transient protection. The transient occurring at the beginning of the fault has strong information to distinguish a faulty from a sound feeder. In this work I have chosen to use not only the transient but also the steady state to get the best sensitivity.<p><p>Then the fault location has been investigated but the small information coming from the faulty feeder is not sufficient to have a precise enough position of the fault. Therefore, active system has been suggested to be implemented in the grid to increase the faulty current and have enough power for a precise location. Different existing algorithms based on the steady state at the nominal frequency are compared using a tool developed during this work. Recommendations are then made depending on the topology, the network parameters, the measurements precision, etc. Due to the complexities of the problem, a simulator has been coded in Matlab .The user of a possible fault location must then use this tool to understand and see the future fault location precision that he could obtain from different algorithm on his network. / Doctorat en Sciences de l'ingénieur / info:eu-repo/semantics/nonPublished
4

Finite element and electrical circuit modelling of faulty induction machines: Study of internal effects and fault detection techniques / Modélisation par éléments finis et par équations de circuits des machines asynchrones en défaut: Etude des effets internes et techniques de détection de défauts

Sprooten, Jonathan 21 September 2007 (has links)
This work is dedicated to faulty induction motors. These motors are often used in industrial applications thanks to their usability and their robustness. However, nowadays optimisation of production becomes so critical that the conceptual reliability of the motor is not sufficient anymore. Motor condition monitoring is expanding to serve maintenance planning and uptime maximisation. Moreover, the use of drive control sensors (namely stator current and voltage) can avoid the installation and maintenance of dedicated sensors for condition monitoring.<p><p>Many authors are working in this field but few approach the diagnosis from a detailed and clear physical understanding of the localised phenomena linked to the faults. Broken bars are known to modulate stator currents but it is shown in this work that it also changes machine saturation level in the neighbourhood of the bar. Furthermore, depending on the voltage level, this change in local saturation affects the amplitude and the phase of the modulation. This is of major importance as most diagnosis techniques use this feature to detect and quantify broken bars. For stator short-circuits, a high current is flowing in the short-circuited coil due to mutual coupling with the other windings and current spikes are flowing in the rotor bars as they pass in front of the short-circuited conductors. In the case of rotor eccentricities, the number of pole-pairs and the connection of these pole-pairs greatly affect the airgap flux density distribution as well as the repartition of the line currents in the different pole-pairs.<p><p>These conclusions are obtained through the use of time-stepping finite element models of the faulty motors. Moreover, circuit models of faulty machines are built based on the conclusions of previously explained fault analysis and on classical Park models. A common mathematical description is used which allows objective comparison of the models for representation of the machine behaviour and computing time.<p><p>The identifiability of the parameters of the models as well as methods for their identification are studied. Focus is set on the representation of the machine behaviour using these parameters more than the precise identification of the parameters. It is shown that some classical parameters can not be uniquely identified using only stator measurements.<p><p>Fault detection and identification using computationally cheap models are compared to advanced detection through motor stator current spectral analysis. This last approach allows faster detection and identification of the fault but leads to incorrect conclusions in low load conditions, in transient situations or in perturbed environments (i.e. fluctuating load torque and unideal supply). Efficient quantification of the fault can be obtained using detection techniques based on the comparison of the process to a model.<p><p>Finally, the work provides guidelines for motor supervision strategies depending on the context of motor utilisation. / Doctorat en Sciences de l'ingénieur / info:eu-repo/semantics/nonPublished

Page generated in 0.1405 seconds