1 |
An investigation of the selective oxidation of NHâ†3 to Nâ†2 by Alâ†2Oâ†3-supported metal oxide catalysts using oxidising conditionsAmblard, Matthieu January 1999 (has links)
No description available.
|
2 |
The surface organometallic chemistry of rhodium and palladium supported on inorganic oxidesBurnaby, Daryl January 2000 (has links)
No description available.
|
3 |
The reactivity of magnesium oxide surfaces towards methane and other moleculesAulton, Simon Philip January 1999 (has links)
No description available.
|
4 |
Desenvolvimento de método analítico rápido de cefalexia na forma pó para suspensão oral por espectroscopia no infravermelho / Development of rapid analytical method of cephalexin in oral suspension powder by infrared spectroscopyOkamoto, Rogerio Takao 28 March 2014 (has links)
A cefalexina é um dos antibióticos mais prescritos no Brasil e a sua disponibilidade nas instituições de saúde é de extrema importância para o tratamento adequado e seguro dos pacientes. Porém a distribuição dos medicamentos é prejudicada pela dificuldade de liberação pelos laboratórios de controle de qualidade que utilizam métodos convencionais como: o biológico (Difusão em Ágar) e o cromatográfico (Cromatografia Líquida de Alta Eficiência), que demandam tempo de análise e não permitem a obtenção de resultados em tempo real. O maior desafio dos centros produtivos é desenvolver métodos capazes de realizarem as análises dos produtos de forma rápida e eficaz durante as fases mais críticas da produção. As técnicas espectroscópicas por infravermelho são alternativas aos métodos convencionais, tendo como vantagens a rapidez, a capacidade de análise de amostras nas suas formas físico-químicas originais e a possibilidade de projetar a sua utilização na Tecnologia Analítica de Processos (PAT). Com esse propósito foi desenvolvido um método por espectroscopia no infravermelho médio (MID) por reflectância difusa (DRIFTS) combinado à técnica de regressão múltipla por mínimos quadrados parciais (PLS) para análise de cefalexina na forma pó para suspensão oral. A avaliação da eficácia do método desenvolvido foi feita mediante cálculo da precisão e exatidão do método e posteriormente os resultados experimentais foram submetidos à análise estatística. A verificação da equivalência dos métodos foi feita utilizando análise de variância (ANOVA) e, para finalizar o trabalho, foi determinado o intervalo de tolerância (δ) do método. O método espectroscópico apresentou significativa variabilidade de resultados, porém uma técnica padronizada de preparo das amostras de calibração capaz de produzir misturas homogêneas do fármaco com placebo, aliado à seleção criteriosa das regiões espectrais e tratamento espectral adequado, foi determinante para o desenvolvimento de um método equivalente aos convencionais, atendendo aos requisitos da PAT. Portanto, este trabalho pode servir de ferramenta para o avanço da PAT pelos produtores e agência regulatória no Brasil (ANVISA). / Cephalexin is the most prescribed antibiotics in Brazil and its availability in health institutions is of utmost importance for the proper and safe treatment of patients. But the distribution of drugs is hindered to difficulty of release by quality control laboratories using conventional methods such as biological (Agar Diffusion) and HPLC (High Performance Liquid Chromatography), which require analysis time and not allow to obtain results in real time. The biggest challenge of manufacturing centers is to develop analytical methods to perform quickly and effectively analyzes of the products during the most critical phases of production. The infrared spectroscopic technique is alternative to conventional methods, with the advantages of speed, the ability to analyze samples in their original physical-chemical forms and the possibility to use in designing the Process Analytical Technology (PAT). For this purpose, a method was developed in the mid-infrared spectroscopy (MID) by diffuse reflectance (DRIFTS) combined to technique of partial least squares (PLS) regression for cephalexin analysis in oral suspension product. Assessing the effectiveness of the method was done by calculation of precision and of the method and then the experimental results were subjected to statistical analysis. The equivalence of methods was verified using analysis of variance (ANOVA) and, to complete the work, the tolerance interval (δ) was determined. The spectroscopic method showed significant variability in results, but a standardized technique for preparation of calibration samples able to produce homogeneous mixtures of the drug with placebo, combined to careful selection of spectral regions and appropriate spectral treatment, was crucial for the development of an equivalent method to conventional, meeting the requirements of PAT. Therefore, this work can serve as a tool for advancing the PAT by manufacturers and regulatory agency in Brazil (ANVISA).
|
5 |
Estudo da redução do NO pelo CO usando catalisadores de ródio suportado em óxido misto de cério e zircônio e óxido misto derivado de hidrotalcita / Study of the reduction of NO by CO using Rh supported on cerium and zirconium mixed oxides and hydrotalcite-like mixed oxides.Daniela Meyer Fernandes Alves 10 December 2013 (has links)
Esta tese teve como objetivo avaliar o desempenho de catalisadores de Rh suportados
em cério-zircônio (CZ) e em óxido misto de magnésio e alumínio (HT) derivado de
hidrotalcita na reação de redução do NO pelo CO em meio estequiométrico. Os suportes puros
e impregnados com Rh foram nomeados CZ, RhCZ, HT e RhHT. Os suportes foram
preparados por coprecipitação e o metal nobre foi adicionado no teor de 0,15% (m/m) por
impregnação a seco. Foram realizados testes de caracterização como fisissorção de N2, DRX,
TPR, espectroscopia Raman, DRIFTS, TGA-DTA e TPD-CO/NO. Para a avaliação catalítica,
foi utilizada uma mistura de 1%NO + 1%CO em He e a atividade e seletividade foram
expressas através das concentrações dos gases envolvidos ao longo de uma rampa de
temperatura desde a temperatura ambiente até 500C. Os resultados de caracterização
indicaram nítidas diferenças estruturais e físico-químicas entre os dois tipos de catalisadores
nas isotermas de adsorção de N2, nos perfis de redução e nos difratogramas, já dando indícios
de que os mecanismos de reação seriam diferentes. Pelas análises de DRIFTS identifica-se a
presença de bandas características de espécies de CO adsorvidas no Rh somente para o
catalisador RhCZ a baixa temperatura, ressaltando a interação Rh-CZ, também evidenciadas
pelos resultados de Raman, mas que provavelmente não ocorrem com o óxido misto de Al e
Mg. Observou-se que o suporte de CZ foi mais ativo a baixas temperaturas que o suporte de
HT, porém o catalisador RhHT foi mais seletivo a N2 a 350C e emitiu menos N2O ao longo
da faixa de temperatura avaliada do que o catalisador RhCZ. Resultados de TPD de NO e
comparações de curvas experimentais e teóricas envolvendo as concentrações de CO, CO2 e
NOx durante os testes catalíticos, acompanhados também pelas análises de DRIFTS nas
mesmas condições, indicam que a redução do Rh e a afinidade do catalisador pelo NO são
importantes para favorecer a maior seletividade da reação de redução do NO pelo CO a N2. / The aim of this work was to evaluate the catalytic performance of cerium-zirconium
and hydrotalcite-like Mg-Al mixed oxide as supports in the reduction of NO by CO catalyzed
by rhodium. The pure supports and metallic catalysts were named CZ, RhCZ, HT and RhHT.
The supports were prepared by coprecipitation and were impregnated with 0,15% wt. of Rh.
Characterization tests such as N2 fisisorption, XRD, TPR, Raman spectroscopy, DRIFTS,
TGA-DTA and NO/CO TPD were performed. To measure the catalytic activity, a gas mixture
containing 1% NO + 1% CO in He was used. Activity and selectivity were expressed by
means of the gas concentrations measured all over a temperature range, from room
temperature to 500C. The characterization results clearly indicated structural and physicochemical
differences between the two supports in N2 adsorption isotherms, XRD and TPR
profiles and therefore, they would work through different mechanisms. DRIFTS analyses
indicated the presence of bands resulting from the adsorption of CO on Rh at low
temperatures on RhCZ catalyst, evidencing the great synergy between Rh and CZ, already
indicated by Raman results. This synergic effect probably did not occur in RhHT catalyst. The
CZ support was more active at low temperatures than HT, however, RhHT catalyst was more
selective to N2 at 350 C and emitted less N2O than RhCZ through the evaluated temperature
range.The NO TPD results and the comparison of theoretical and experimental CO, CO2 and
NOx curves during catalytic tests, also followed by DRIFTS, indicate that Rh reduction and
the affinity with NO are important parameters to achieve higher selectivity to N2 in the
reduction of NO by CO.
|
6 |
Estudo da redução do NO pelo CO usando catalisadores de ródio suportado em óxido misto de cério e zircônio e óxido misto derivado de hidrotalcita / Study of the reduction of NO by CO using Rh supported on cerium and zirconium mixed oxides and hydrotalcite-like mixed oxides.Daniela Meyer Fernandes Alves 10 December 2013 (has links)
Esta tese teve como objetivo avaliar o desempenho de catalisadores de Rh suportados
em cério-zircônio (CZ) e em óxido misto de magnésio e alumínio (HT) derivado de
hidrotalcita na reação de redução do NO pelo CO em meio estequiométrico. Os suportes puros
e impregnados com Rh foram nomeados CZ, RhCZ, HT e RhHT. Os suportes foram
preparados por coprecipitação e o metal nobre foi adicionado no teor de 0,15% (m/m) por
impregnação a seco. Foram realizados testes de caracterização como fisissorção de N2, DRX,
TPR, espectroscopia Raman, DRIFTS, TGA-DTA e TPD-CO/NO. Para a avaliação catalítica,
foi utilizada uma mistura de 1%NO + 1%CO em He e a atividade e seletividade foram
expressas através das concentrações dos gases envolvidos ao longo de uma rampa de
temperatura desde a temperatura ambiente até 500C. Os resultados de caracterização
indicaram nítidas diferenças estruturais e físico-químicas entre os dois tipos de catalisadores
nas isotermas de adsorção de N2, nos perfis de redução e nos difratogramas, já dando indícios
de que os mecanismos de reação seriam diferentes. Pelas análises de DRIFTS identifica-se a
presença de bandas características de espécies de CO adsorvidas no Rh somente para o
catalisador RhCZ a baixa temperatura, ressaltando a interação Rh-CZ, também evidenciadas
pelos resultados de Raman, mas que provavelmente não ocorrem com o óxido misto de Al e
Mg. Observou-se que o suporte de CZ foi mais ativo a baixas temperaturas que o suporte de
HT, porém o catalisador RhHT foi mais seletivo a N2 a 350C e emitiu menos N2O ao longo
da faixa de temperatura avaliada do que o catalisador RhCZ. Resultados de TPD de NO e
comparações de curvas experimentais e teóricas envolvendo as concentrações de CO, CO2 e
NOx durante os testes catalíticos, acompanhados também pelas análises de DRIFTS nas
mesmas condições, indicam que a redução do Rh e a afinidade do catalisador pelo NO são
importantes para favorecer a maior seletividade da reação de redução do NO pelo CO a N2. / The aim of this work was to evaluate the catalytic performance of cerium-zirconium
and hydrotalcite-like Mg-Al mixed oxide as supports in the reduction of NO by CO catalyzed
by rhodium. The pure supports and metallic catalysts were named CZ, RhCZ, HT and RhHT.
The supports were prepared by coprecipitation and were impregnated with 0,15% wt. of Rh.
Characterization tests such as N2 fisisorption, XRD, TPR, Raman spectroscopy, DRIFTS,
TGA-DTA and NO/CO TPD were performed. To measure the catalytic activity, a gas mixture
containing 1% NO + 1% CO in He was used. Activity and selectivity were expressed by
means of the gas concentrations measured all over a temperature range, from room
temperature to 500C. The characterization results clearly indicated structural and physicochemical
differences between the two supports in N2 adsorption isotherms, XRD and TPR
profiles and therefore, they would work through different mechanisms. DRIFTS analyses
indicated the presence of bands resulting from the adsorption of CO on Rh at low
temperatures on RhCZ catalyst, evidencing the great synergy between Rh and CZ, already
indicated by Raman results. This synergic effect probably did not occur in RhHT catalyst. The
CZ support was more active at low temperatures than HT, however, RhHT catalyst was more
selective to N2 at 350 C and emitted less N2O than RhCZ through the evaluated temperature
range.The NO TPD results and the comparison of theoretical and experimental CO, CO2 and
NOx curves during catalytic tests, also followed by DRIFTS, indicate that Rh reduction and
the affinity with NO are important parameters to achieve higher selectivity to N2 in the
reduction of NO by CO.
|
7 |
Desenvolvimento de método analítico rápido de cefalexia na forma pó para suspensão oral por espectroscopia no infravermelho / Development of rapid analytical method of cephalexin in oral suspension powder by infrared spectroscopyRogerio Takao Okamoto 28 March 2014 (has links)
A cefalexina é um dos antibióticos mais prescritos no Brasil e a sua disponibilidade nas instituições de saúde é de extrema importância para o tratamento adequado e seguro dos pacientes. Porém a distribuição dos medicamentos é prejudicada pela dificuldade de liberação pelos laboratórios de controle de qualidade que utilizam métodos convencionais como: o biológico (Difusão em Ágar) e o cromatográfico (Cromatografia Líquida de Alta Eficiência), que demandam tempo de análise e não permitem a obtenção de resultados em tempo real. O maior desafio dos centros produtivos é desenvolver métodos capazes de realizarem as análises dos produtos de forma rápida e eficaz durante as fases mais críticas da produção. As técnicas espectroscópicas por infravermelho são alternativas aos métodos convencionais, tendo como vantagens a rapidez, a capacidade de análise de amostras nas suas formas físico-químicas originais e a possibilidade de projetar a sua utilização na Tecnologia Analítica de Processos (PAT). Com esse propósito foi desenvolvido um método por espectroscopia no infravermelho médio (MID) por reflectância difusa (DRIFTS) combinado à técnica de regressão múltipla por mínimos quadrados parciais (PLS) para análise de cefalexina na forma pó para suspensão oral. A avaliação da eficácia do método desenvolvido foi feita mediante cálculo da precisão e exatidão do método e posteriormente os resultados experimentais foram submetidos à análise estatística. A verificação da equivalência dos métodos foi feita utilizando análise de variância (ANOVA) e, para finalizar o trabalho, foi determinado o intervalo de tolerância (δ) do método. O método espectroscópico apresentou significativa variabilidade de resultados, porém uma técnica padronizada de preparo das amostras de calibração capaz de produzir misturas homogêneas do fármaco com placebo, aliado à seleção criteriosa das regiões espectrais e tratamento espectral adequado, foi determinante para o desenvolvimento de um método equivalente aos convencionais, atendendo aos requisitos da PAT. Portanto, este trabalho pode servir de ferramenta para o avanço da PAT pelos produtores e agência regulatória no Brasil (ANVISA). / Cephalexin is the most prescribed antibiotics in Brazil and its availability in health institutions is of utmost importance for the proper and safe treatment of patients. But the distribution of drugs is hindered to difficulty of release by quality control laboratories using conventional methods such as biological (Agar Diffusion) and HPLC (High Performance Liquid Chromatography), which require analysis time and not allow to obtain results in real time. The biggest challenge of manufacturing centers is to develop analytical methods to perform quickly and effectively analyzes of the products during the most critical phases of production. The infrared spectroscopic technique is alternative to conventional methods, with the advantages of speed, the ability to analyze samples in their original physical-chemical forms and the possibility to use in designing the Process Analytical Technology (PAT). For this purpose, a method was developed in the mid-infrared spectroscopy (MID) by diffuse reflectance (DRIFTS) combined to technique of partial least squares (PLS) regression for cephalexin analysis in oral suspension product. Assessing the effectiveness of the method was done by calculation of precision and of the method and then the experimental results were subjected to statistical analysis. The equivalence of methods was verified using analysis of variance (ANOVA) and, to complete the work, the tolerance interval (δ) was determined. The spectroscopic method showed significant variability in results, but a standardized technique for preparation of calibration samples able to produce homogeneous mixtures of the drug with placebo, combined to careful selection of spectral regions and appropriate spectral treatment, was crucial for the development of an equivalent method to conventional, meeting the requirements of PAT. Therefore, this work can serve as a tool for advancing the PAT by manufacturers and regulatory agency in Brazil (ANVISA).
|
8 |
Valorisation catalytique de produits oxygénés issue des biorafinneries de lingo-cellulose / Catalytic upgrading of oxygenated building blocks in lignocellulose based biorefineriesZhang, Yu 19 January 2017 (has links)
Cette thèse porte sur l'hydrogénation en phase gazeuse du furfural sur des oxydes de fer et de magnésium. De nombreux catalyseurs avec différents ratio molaires en fer et magnésium ont été préparés par des méthodes de co-précipitation ou d'imprégnation. Ils ont été ensuite testés lors de la réduction du furfural (FU) en utilisant du méthanol comme donneur d'hydrogène. L'alcool furfurylique (FAL) et le 2-methyl furfural (MFU) étaient les principaux produits obtenus démontrant alors que les systèmes Mg/Fe/O peuvent favoriser les réactions d'hydrogénation séquentielles et d'hydrogénolyse. Les catalyseurs imprégnés se sont révélés plus actif et sélectif vis-à-vis des MFU que ceux préparés par co-précipitation. Les données rapportées ont montré que la distribution du produit était fortement influencée par la teneur en fer et par l'acide résultant, ainsi que les propriétés d'oxydoréduction du matériau. En effet, l'introduction de fer à la surface d'oxyde basique a conduit à l'addition d'acidité de Lewis et de potentiel d'oxydoréduction dans le système, améliorant significativement la conversion de FU et la production de MFU. L'activation des différentes espèces à la surface du catalyseur a été étudié in-situ par DRIFTS et FTIR. Les résultats révèlent que la basicité du MgO favorise l'activation du méthanol et que le potentiel d'oxydoréduction du FeOx pourrait être responsable de l'hydrogénolyse de l'alcool furfurylique / This PhD project is focused on the gas phase hydrogenation of furfural over iron and magnesium oxides. Numerous catalysts with different iron and magnesium molar ratios, were prepared by co-precipitation or impregnation methods and were tested for the reduction of furfural (FU) using methanol as hydrogen donor. Furfuryl alcohol (FAL) and 2-methyl furfural (MFU) were the main products obtained, demonstrating that Mg/Fe/O systems can promote sequential hydrogenation and hydrogenolysis reactions. Impregnated catalysts demonstrated to be more active and selective towards MFU than co-precipitated ones. Reported data demonstrated that product distribution was strongly influenced by the iron content and from the resulting acid and redox properties of the material. As a matter of fact, the introduction of iron on the surface of the basic oxide led to the addition of Lewis acidity and redox capacity in the system, significantly enhancing FU conversion and MFU production. The activation of different species on the catalyst surface has been studied by in situ DRIFTS and FTIR. The results reveal that the MgO basicity favors methanol activation and FeOx redox capacity might be the responsible of furfuryl alcohol hydrogenolysis
|
9 |
Acidity Characterization And Adsorption Characteristics Of Cobalt And Lead Doped Sba-15 Mesoporous MaterialsGuner, Ozge 01 September 2007 (has links) (PDF)
In this study, the surface acidity of Co and/or Pb doped SBA15 mesoporous catalysts were investigated by both diffuse reflectance fourier transform (DRIFT) infrared spectroscopy and transmission mode fourier transform infrared spectroscopy. Pyridine was used to identify the Brø / nsted and Lewis acid sites of the surface, at room temperature. From the DRIFT spectrum typical stretching vibrations of isolated terminal silanol (Si-OH) groups were observed for all the catalysts. These silanol group bands dissappeared after pyridine adsorption, indicating that these silanol groups are acidic and serve as chemical adsorption sites for pyridine. Pyridine adsorption on these catalysts revealed that while monometallic additions did not influence the overall acidity of SBA15, in the bimetallic system, characteristic bands due to pyridine adsorption on Co2+ ions were observed.
|
10 |
Diffraction imaging of sediment drifts in the Canterbury Basin, New ZealandAl-Hadab, Salah Ahmad 25 April 2013 (has links)
Analysis of scattered, or diffraction energy (the seismic response of small-scale
objects) in the seismic data from Canterbury Basin, New Zealand reveals additional
geological information about depositional patterns in sedimentary deposits. Diffrac-
tion images from the seismic response for Canterbury Basin provide complementary
interpretation tools to the conventional specular reflection images. To image diffrac-
tions for a dataset from Canterbury Basin, I take the following steps: First, I attenuate
multiples using a surface multiple prediction algorithm to predict multiples and apply
regularized nonstationary regression to adaptively subtract the predicted multiples.
Next, I separate diffractions using the plane-wave destruction method. The plane-
wave destruction method removes conventional reflected energy in order to enhance
the diffracted energy. I then apply a velocity continuation method on diffraction data
to estimate migration velocities and then migrate the data using Kirchhoff migration
in the dip-angle-gather domain. The resultant conventional and diffraction images are
improved images suitable for geological interpretation of prograding sediment drifts. / text
|
Page generated in 0.0285 seconds