• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • Tagged with
  • 14
  • 14
  • 13
  • 11
  • 8
  • 7
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Desenvolvimento de metodologias indicativas de estabilidade para medicamentos que atuam no diabetes mellitus tipo II / Development of stability indicating methods for drugs that are used in diabetes mellitus 2

Galdos, Angel Arturo Gaona 23 November 2012 (has links)
O diabetes mellitus (DM) é uma síndrome na qual o metabolismo de hidratos de carbono, gorduras e proteínas está alterado, por falta de secreção de insulina ou por diminuição da sensibilidade tissular a este hormônio. O DM pode ser do tipo I, também denominado diabetes mellitus insulinodependente (DMID), caracterizado pela falta de secreção da insulina, e do tipo II, também denominado diabetes mellitus não insulinodependente (DMNID), caracterizado pela menor sensibilidade dos tecidos efetores às ações metabólicas da insulina. Embora ainda não haja cura definitiva, há vários tratamentos disponíveis que proporcionam qualidade de vida para o paciente portador, como a administração de hipoglicemiantes orais. Nesta pesquisa, objetivou-se desenvolver métodos indicativos de estabilidade para a glibenclamida e o cloridrato de metformina. Assim, foram desenvolvidos métodos de rastreamento ortogonais utilizando a cromatografia líquida de alta eficiência (HPLC) e a eletroforese capilar (CE), metodologias que foram desafiadas com os estudos da degradação forçada. Realizou-se, também, a identificação do principal produto de degradação da glibenclamida utilizando a cromatografia líquida acoplada à espectrometria de massa (LC-MS). O método por HPLC teve o melhor desempenho no monitoramento dos produtos de degradação da glibenclamida, apresentando boa linearidade nas concentrações entre 0,210 e 0,360 mg/mL; com coeficiente de correlação maior de 0,99. A precisão calculada como desvio padrão relativo (DPR) foi menor de 3%, exatidão do método comprovada mediante teste de recuperação, obtendo-se valores de 100±3,0%. No teste de especificidade, foram detectados três potenciais produtos de degradação, com os seguintes tempos de retenção relativos (TRR) de 0,33; 0,46 e 0,83. O método CZE teve o melhor desempenho no monitoramento dos produtos de degradação do cloridrato de metformina, apresentando boa linearidade nas concentrações entre 0,210 e 0,360 mg/mL, com coeficiente de correlação maior de 0,99. A precisão, calculada como DPR, foi menor do que 5%, exatidão do método comprovada mediante o teste de recuperação, obtendo-se valores de 100±3,5%. No teste de especificidade, foram detectados cinco potenciais produtos de degradação com os seguintes TRRs de 0,90; 1,14; 1,35; 1,45 e 1,56. / Diabetes mellitus (DM) is a syndrome which alters the metabolism of carbohydrates, fats and proteins by lack of insulin secretion or a decrease in tissue sensitivity to insulin. Type 1 DM is also known as insulin-dependent diabetes mellitus is characterized by lack of insulin secretion. The second type of diabetes known as Type II, also called non-insulin dependent, is characterized by the reduced sensitivity of target tissues to the metabolic actions of insulin. Although there is no definitive cure, there are several treatments available that provide quality of life for the patient how treatment with oral hypoglycemic agents. This study had as objective to developed stability-indicating methods for glibenclamide and metformin hydrochloride. Thus, the techniques used in this study involved high performance liquid chromatography (HPLC) and capillary electrophoresis (CE), and both were challenged with forced degradation studies. The identification of degradation products of glibenclamide was also performed, utilizing the mass spectrometry (MS) technique. However, the HPLC technique had the best performance for monitoring the degradation products of glibenclamide, which showed a good linearity in concentrations between 0.210 - 0.360 mg/ml, with a correlation coefficient greater than 0.99. The precision was calculated as a relative standard deviation (RSD) which was less than 3%; the accuracy of the method calculated as the percent recovery was obtained with the following values: 100 ± 3.0%. On the specificity were detected three potential products of degradation utilizing forced degradation, with the following relative retention times (RRT) 0.33, 0.46 and 0.83. The CZE method had the best performance to monitoring the degradation products of metformin hydrochloride, which showed good linearity of concentrations between 0.210 and 0.360 mg/ml, with a correlation coefficient greater than 0.99. The intra-day and inter-day precision calculated as DPR was less than 5%, and an accuracy of this method was achieved using the values of 100 ± 3.5%. In the specificity were five potential degradation products were detected with the following TRRS: 0.90, 1.14, 1.35, 1.45 and 1.56.
12

Desenvolvimento de metodologias indicativas de estabilidade para medicamentos que atuam no diabetes mellitus tipo II / Development of stability indicating methods for drugs that are used in diabetes mellitus 2

Angel Arturo Gaona Galdos 23 November 2012 (has links)
O diabetes mellitus (DM) é uma síndrome na qual o metabolismo de hidratos de carbono, gorduras e proteínas está alterado, por falta de secreção de insulina ou por diminuição da sensibilidade tissular a este hormônio. O DM pode ser do tipo I, também denominado diabetes mellitus insulinodependente (DMID), caracterizado pela falta de secreção da insulina, e do tipo II, também denominado diabetes mellitus não insulinodependente (DMNID), caracterizado pela menor sensibilidade dos tecidos efetores às ações metabólicas da insulina. Embora ainda não haja cura definitiva, há vários tratamentos disponíveis que proporcionam qualidade de vida para o paciente portador, como a administração de hipoglicemiantes orais. Nesta pesquisa, objetivou-se desenvolver métodos indicativos de estabilidade para a glibenclamida e o cloridrato de metformina. Assim, foram desenvolvidos métodos de rastreamento ortogonais utilizando a cromatografia líquida de alta eficiência (HPLC) e a eletroforese capilar (CE), metodologias que foram desafiadas com os estudos da degradação forçada. Realizou-se, também, a identificação do principal produto de degradação da glibenclamida utilizando a cromatografia líquida acoplada à espectrometria de massa (LC-MS). O método por HPLC teve o melhor desempenho no monitoramento dos produtos de degradação da glibenclamida, apresentando boa linearidade nas concentrações entre 0,210 e 0,360 mg/mL; com coeficiente de correlação maior de 0,99. A precisão calculada como desvio padrão relativo (DPR) foi menor de 3%, exatidão do método comprovada mediante teste de recuperação, obtendo-se valores de 100±3,0%. No teste de especificidade, foram detectados três potenciais produtos de degradação, com os seguintes tempos de retenção relativos (TRR) de 0,33; 0,46 e 0,83. O método CZE teve o melhor desempenho no monitoramento dos produtos de degradação do cloridrato de metformina, apresentando boa linearidade nas concentrações entre 0,210 e 0,360 mg/mL, com coeficiente de correlação maior de 0,99. A precisão, calculada como DPR, foi menor do que 5%, exatidão do método comprovada mediante o teste de recuperação, obtendo-se valores de 100±3,5%. No teste de especificidade, foram detectados cinco potenciais produtos de degradação com os seguintes TRRs de 0,90; 1,14; 1,35; 1,45 e 1,56. / Diabetes mellitus (DM) is a syndrome which alters the metabolism of carbohydrates, fats and proteins by lack of insulin secretion or a decrease in tissue sensitivity to insulin. Type 1 DM is also known as insulin-dependent diabetes mellitus is characterized by lack of insulin secretion. The second type of diabetes known as Type II, also called non-insulin dependent, is characterized by the reduced sensitivity of target tissues to the metabolic actions of insulin. Although there is no definitive cure, there are several treatments available that provide quality of life for the patient how treatment with oral hypoglycemic agents. This study had as objective to developed stability-indicating methods for glibenclamide and metformin hydrochloride. Thus, the techniques used in this study involved high performance liquid chromatography (HPLC) and capillary electrophoresis (CE), and both were challenged with forced degradation studies. The identification of degradation products of glibenclamide was also performed, utilizing the mass spectrometry (MS) technique. However, the HPLC technique had the best performance for monitoring the degradation products of glibenclamide, which showed a good linearity in concentrations between 0.210 - 0.360 mg/ml, with a correlation coefficient greater than 0.99. The precision was calculated as a relative standard deviation (RSD) which was less than 3%; the accuracy of the method calculated as the percent recovery was obtained with the following values: 100 ± 3.0%. On the specificity were detected three potential products of degradation utilizing forced degradation, with the following relative retention times (RRT) 0.33, 0.46 and 0.83. The CZE method had the best performance to monitoring the degradation products of metformin hydrochloride, which showed good linearity of concentrations between 0.210 and 0.360 mg/ml, with a correlation coefficient greater than 0.99. The intra-day and inter-day precision calculated as DPR was less than 5%, and an accuracy of this method was achieved using the values of 100 ± 3.5%. In the specificity were five potential degradation products were detected with the following TRRS: 0.90, 1.14, 1.35, 1.45 and 1.56.
13

Desenvolvimento de metodologias indicativas de estabilidade para medicamentos utilizados como diuréticos / Development of stability-indicating assay for diuretics drugs.

Aline de Souza 11 December 2015 (has links)
Os diuréticos aumentam o fluxo urinário e a excreção de sódio e são utilizados para ajustar o volume e/ou a composição dos líquidos corporais em uma variedade de situações clínicas. A furosemida é um agente diurético potente que induz uma poderosa diurese. É utilizada no tratamento de edema associado com o coração e doenças renais. Nesta pesquisa objetivou-se desenvolver métodos indicativos de estabilidade para a furosemida, por eletroforese capilar em solução livre (FSCE) e cromatografia liquida de alta eficiência (CLAE). O método por FSCE utilizou um capilar de sílica fundida com comprimento total de 30,2 cm x 50,0 µm d.i. O tampão utilizado foi tetraborato de sódio 2,0 mmol L-1 e 10% de metanol, injeção hidrodinâmica 0,5 psi/5s, tensão aplicada +25 kV, detecção em 273 nm e temperatura a 25ºC. O tempo de migração da furosemida foi de 1,8 minutos. O método obteve boa linearidade no intervalo de 70,0 a 130,0 µg.mL-1 com coeficiente de correlação maior de 0,99. Os limites de detecção e de quantificação foram 6,2 µg.mL-1 e 20,6 µg.mL-1, respectivamente. A precisão do sistema foi inferior a 2,0%. A repetibilidade e precisão intermediária foram inferiores a 5,0%. A recuperação média foi de 102,1 %. No teste de especificidade, foram detectados três potenciais produtos de degradação com os seguintes tempos de retenção 1,3 2,0 e 2,2 min. O método por CLAE utilizou uma coluna Shim-pack CLC-ODS(M)® (250mm x4.6mm, 5µm). A fase móvel era constituída de acetonitrila:água (50:50) com 0,1% de ácido fórmico. O fluxo foi de 1.0 mL min-1 e detecção em 273 nm e temperatura a 30 ± 1 ºC. O método apresentou boa linearidade nas concentrações entre 7,0 e 13 µg.mL-1; com coeficiente de correlação maior de 0,99. E tempo de retenção para furosemida foi de 4,9 minutos. Os limites de detecção e de quantificação foram 0,6 µg.mL-1 e 1,9 µg.mL-1, respectivamente. A precisão do sistema foi inferior a 1,0%. A repetibilidade e precisão intermediária foram inferiores a 3,0%. A recuperação média foi de 105,1 %. No teste de especificidade, foram detectados três potenciais produtos de degradação com os seguintes tempos de retenção 2,4, 3,1 e 3,8 min. / Diuretics increase urine flow and sodium excretion and are used to adjust volume and / or composition of body fluids in a variety of clinical situations. Furosemide is a potent diuretic agent that induces a strong diuresis. It is used in the treatment of edema associated with heart and kidney disease. This research aimed to develop stability indicative methods for furosemide, by capillary electrophoresis in free solution (FSCE) and high-performance liquid chromatography (HPLC). The method FSCE used a fused silica capillary with a total length of 30.2 cm x 50.0 um di The buffer used was sodium tetraborate 2.0 mmol L-1 and 10% methanol, hydrodynamic injection 0.5 psi / 5s, +25 kV applied voltage, detection at 273 nm and 25 °C. The furosemide migration time was 1.8 minutes. The method achieved good linearity in the range of 70.0 to 130.0 µg.mL-1 with correlation coefficient higher of 0.99. The limits of detection and quantification were 6.2 and 20.6 µg.mL-1 µg.mL-1, respectively. The system accuracy was less than 2.0%. The repeatability and intermediate precision were less than 5.0%. The average recovery was 102.1%. The specificity test detected three potential degradation products with the following retention times 1.3, 2.0 and 2.2 min. The HPLC method used a Shim-pack CLC-ODS (M)® column (250mm x 4.6mm, 5µm). The mobile phase consisted of acetonitrile: water (50:50) with 0.1% formic acid. The flow rate was 1.0 mL min-1, detection at 273 nm and temperature at 30 ± 1°C. The method showed good linearity in concentrations between 7.0 and 13.0 µg.mL-1; with correlation coefficient higher of 0.99. Retention time for furosemide was 4.9 minutes. The limits of detection and quantification were 0.6 µg.mL-1 and 1.9 µg.mL-1, respectively. The system accuracy was less than 1.0%. The repeatability and intermediate precision were less than 3.0%. The average recovery was 105.1%. The specificity test detected three potential degradation products of the following retention times of 2.4, 3.1 and 3.8 min.
14

Análise por RMN de produtos de degradação forçada em fármacos / NMR analysis of forced degradation products in drugs

Isler, Ana Cristina, 1981- 10 January 2014 (has links)
Orientador: Alviclér Magalhães / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-27T01:53:53Z (GMT). No. of bitstreams: 1 Isler_AnaCristina_M.pdf: 9031624 bytes, checksum: 46ef4af84056b43b2f82f7756c9e1ae7 (MD5) Previous issue date: 2014 / Resumo: A degradação forçada ou teste de estresse é uma boa estratégia para demonstrar as rotas de degradação e os produtos formados durante a estocagem do fármaco ou do produto formulado. O principal objetivo desse teste é demonstrar a especificidade dos métodos indicativos de estabilidade. Tratam-se de ensaios que visam desafiar e confirmar a especificidade e seletividade da metodologia analítica empregada na quantificação do princípio ativo presente no medicamento e na manutenção dessas característica ao longo do estudo de estabilidade. É comum o emprego de métodos cromatográficos na indústria farmacêutica para análise de impurezas que trabalham através da co injeção de padrões de referência. Esta é uma tarefa simples quando se tratam de produtos de degradação conhecidos e disponíveis em suas formas puras. Entretanto, quando se trata de um medicamento novo, com perfil de degradação ainda não estabelecido, a técnica de ressonância magnética nuclear (RMN) pode facilitar essa investigação por sua versatilidade em relação aos meios utilizados nas análises e ao preparo da amostra. Considerando que o meio reacional de degradação de um fármaco deve consistir de uma mistura de compostos, esse trabalho foi realizado na tentativa de elucidar estruturalmente o fármaco Rosuvastatina e seus produtos de degradação em diferentes meios de reação, resolvendo sempre que possível e necessário o problema de sobreposição de sinais, através de espectros bidimensionais e sequências de pulso para detecção seletiva, aumentando a sensibilidade e resolução espectral / Abstract: Forced degradation or stress testing is a good strategy to show the routes of degradation and products formed during storage of the drug or the formulated product. The main objective of this test is to demonstrate the specificity of indicative methods of stability. These are tests that aim to challenge and confirm the specificity and selectivity of the analytical methodology used to quantify the active ingredient present in the product and maintenance of the characteristic along the stability study. It is common to use chromatographic methods in the pharmaceutical industry for the analysis of impurities working through co injection of assay standards. This is a simple task when dealing with known and available degradation products in their pure forms. However, when it comes to a new product with degradation profile is not yet established, the technique of nuclear magnetic resonance (NMR) can facilitate such research for their versatility on the resources used in the analysis and sample preparation. Whereas the reaction medium of degradation of a drug should consist of a mixture of compounds, this work was undertaken in an attempt to elucidate the structural of rosuvastatin drug degradation products in different reaction media, whenever was possible and necessary two-dimensional spectra and pulse sequences with selective detection were used to solve the problem of overlapping signals, increase sensitivity and spectral resolution / Mestrado / Quimica Organica / Mestra em Química

Page generated in 0.0647 seconds