• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 28
  • 20
  • 1
  • Tagged with
  • 49
  • 49
  • 49
  • 17
  • 16
  • 16
  • 11
  • 9
  • 8
  • 8
  • 8
  • 8
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Photoelastic analysis of stress distribution around external hexagon and morse taper implants in different immediate loading systems = Análise fotoelástica da distribuição de tensões ao redor de implantes hexágono externo e cone Morse em diferentes sistemas de carga imediata / Análise fotoelástica da distribuição de tensões ao redor de implantes hexágono externo e cone Morse em diferentes sistemas de carga imediata

Odo, Caroline Hanada, 1987- 22 August 2018 (has links)
Orientador: Mauro Antônio de Arruda Nóbilo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T01:43:18Z (GMT). No. of bitstreams: 1 Odo_CarolineHanada_M.pdf: 1232143 bytes, checksum: 6ae3560319ddd48973319b39e8cbe764 (MD5) Previous issue date: 2013 / Resumo: Dentre diversos fatores que determinam o sucesso da osseointegração e da reabilitação protética, a biomecânica se destaca como fator fundamental. Utilizando a técnica da fotoelasticidade, o objetivo neste estudo foi avaliar as tensões geradas ao redor de implantes cone morse e hexágono externo osseointegrados após carregamento distal em diferentes técnicas de carga imediata: barra distal, fundição e solda a Laser. Três infraestruturas similares (uma para cada técnica) foram confeccionadas, sobre uma matriz metálica simulando um arco mandibular edêntulo. Cinco implantes foram dispostos de maneira a simular a distribuição clínica para protocolo inferior convencional. Análogos de mini pilares foram fixados na matriz metálica e após procedimento de transferência e obtenção de modelo em gesso especial, foram confeccionadas as infraestruturas protéticas. Estas foram utilizadas em novo procedimento de transferência e posteriormente, instaladas em modelo fotoelástico confeccionado com resina epóxi flexível (GIV, Polipox Indústria e Comércio Ltda - São Paulo - SP - Brasil). Foi realizado um carregamento pontual de 4,9N na região de primeiro molar inferior direito e, posteriormente primeiro molar inferior esquerdo. Foram avaliados cinco pontos pré-determinados ao longo do implante e as imagens foram analisadas no programa Fringes® de maneira qualitativa e quantitativa através da verificação das ordens de franjas ao redor dos implantes osseointegrados. A média dos valores foi submetida à análise de variância para dados com dois fatores de estudo, seguidos pelo teste de Tukey para comparação entre as médias. Os resultados não apresentaram diferença significativa entre as infraestruturas, porém apresentou diferença significativa entre os tipos de conexões. A partir dos resultados obtidos conclui-se que não há diferença na distribuição de tensão entre as técnicas de obtenção de infraestruturas, porém quando observados os tipos de conexão, o implante Cone Morse apresentou melhores resultados em relação à distribuição de tensão / Abstract: The objective of this study was to evaluate the stresses generated around morse taper and external hexagon osseointegrated implants after distal loading in different immediate loading techniques: distal bar, casting and laser welding. Three similar infrastructures (one for each technique) were fabricated on a metal matrix simulating an edentulous mandible arch. Five implants were arranged to simulate the clinical distribution of conventional lower protocol. Analogs of the implants were fixed in a metal matrix and a transfer procedure was made. After obtaining a special plaster model, the prosthetic infrastructures were fabricated. These were used on a new transfer procedure and subsequently installed in a photoelastic model made with flexible epoxy resin (GIV Polipox Industry and Commerce Ltd - São Paulo - SP - Brazil). A load application of 4.9N was performed at the region of lower right first molar and subsequently lower left first molar. Five predetermined points along the implant were evaluated and the images were analyzed in Fringes ® program in qualitative and quantitative way by checking the orders of the fringes around the dental implants. The mean values were statistically analyzed using a 2-Way analysis of variance and Tukey test. The results showed no significant difference between the infrastructure obtaining techniques, but significant difference was seen between the types of connection. From the results obtained it is concluded that the Morse taper implant showed better results in terms of stress distribution / Mestrado / Protese Dental / Mestra em Clínica Odontológica
22

"Estudo comparativo de dois métodos utilizados na fundição de titânio cp" / Comparative study of two cp Ti casting methods.

Rodrigues, Renata Cristina Silveira 29 April 2005 (has links)
Ao longo da última década, vários trabalhos têm destacado as vantagens do titânio e suas ligas e estudado a possibilidade de utilização para a confecção de estruturas metálicas de prótese parcial removível. Apesar das vantagens, o processo de fundição ainda apresenta problemas, limitando o uso do titânio. O objetivo deste estudo foi avaliar a influência de dois métodos de fundição, sobre microestrutura, microdureza, porosidade e força de retenção de grampos de PPR, fundidos em Co-Cr (controle) e titânio comercialmente puro (Ti cp). Foram utilizados os seguintes métodos: 1- arco voltaico (plasma) sob vácuo e pressão de argônio, com injeção do metal fundido por vácuo-pressão, e 2- indução sob vácuo e atmosfera de argônio, com injeção do metal fundido por centrifugação. Para análise da força de retenção foram confeccionadas estruturas metálicas com grampos circunferenciais sob retenção de 0,25; 0,50 e 0,75 mm, submetidas a ciclos de inserção/remoção simulando o uso por um período de 5 anos. Previamente ao ensaio de simulação, os corpos-de-prova foram radiografados em unidade laboratorial de raios X. Para o ensaio de microdureza Vickers e microestrutura foram confeccionados discos, com 5 mm de diâmetro e 2 mm de espessura, polidos metalograficamente. Os resultados mostraram que os métodos de fundição interferem nas características dos materiais estudados. As peças em titânio cp fundidas por plasma/vácuo-pressão apresentaram maior número de porosidades (50%) do que as fundidas por indução/centrifugação (16,66%). Para as peças fundidas em liga de Co-Cr, segundo a metodologia empregada, não foi possível observar a ocorrência de porosidades. As peças fundidas por plasma/vácuo-pressão apresentaram maior flexibilidade e as fundidas por indução/centrifugação apresentaram maior rigidez. Conseqüentemente, as forças de retenção foram, em geral, maiores para os corpos-de-prova obtidos por indução/centrifugação do que para aqueles obtidos por plasma/vácuo-pressão, com exceção da condição experimental de retenção 0,75 mm. Os corpos-de-prova fundidos por indução/centrifugação apresentaram, tanto para o Ti cp quanto para a liga de Co-Cr, maiores valores de microdureza Vickers do que os fundidos por plasma/vácuo-pressão. O Ti cp fundido pelo método de indução/centrifugação resultou em microestrutura de aspecto Widmanstätten, enquanto quando fundido pelo método de plasma/vácuo-pressão tem aspecto metalográfico tipo feather-like. Para a liga de Co-Cr, ambos os métodos resultaram em microestrutura dendrítica, mais fina para o método de plasma/vácuo-pressão. O Ti cp e a liga de Co-Cr, parecem ser afetados pela velocidade de resfriamento associada ao equipamento utilizado. Na análise química não foram detectadas alterações de composição dos materiais que indicassem contaminação resultante dos métodos de fundição utilizados. Assim, embora ainda apresentem problemas técnicos a serem resolvidos, ambos os métodos de fundição, indução/centrifugação e plasma/vácuo-pressão, permitem a obtenção de resultados satisfatórios na produção de estruturas metálicas de PPR em Ti cp. / Along the last decade, several jobs have been highlighting the advantages of titanium and titanium alloys and studied the possible utilization for removable partial dentures (RPD) metal frameworks confection. Although advantages, the cast process still presents problems, limiting the titanium use. The objective of this study was to evaluate the influence of two casting methods, on microstructure, microhardness, porosity and retention force of RPD clasps, casted in Co-Cr alloy (control) and commercially pure titanium (cp Ti). The cast methods used were: 1- voltaic arc (plasma) under vacuum and argon pressure, with molten metal injection by vacuum-pressure, and 2- induction under vacuum and argon atmosphere, with molten metal injection by centrifugation. For retention force analysis were made metal frameworks with circumferential clasps under retention of 0.25; 0.50 and 0.75 mm, submitted to insertion/removal cycles, simulating a 5 years use of a metal framework. Previously to the simulation test, the samples were radiographed in a laboratorial unit to verify the porosities occurrence. For Vickers microhardness test and microstructure analysis, disks with 5mm diameter and 2 mm thickness were made. The results showed that the casting methods interfere in the characteristics of studied materials. The cp Ti pieces casted by plasma/vacuum-pressure presents larger porosities number (50%) than that casted by induction/centrifugation (16.66%). For the pieces casted in Co-Cr alloy, according to the used methodology, wasn't possible to observe the occurrence of porosities. The pieces casted by plasma/vacuum-pressure presents larger flexibility and that casted by induction/centrifugation present larger rigidity. Consequently, the retention forces were, in general, larger for the samples obtained by induction/centrifugation than for those obtained by plasma/vacuum-pressure, except for the experimental condition with 0.75 mm retention. The samples casted by induction/centrifugation present, as for cp Ti as for Co-Cr alloy, larger Vickers microhardness values Vickers than that casted by plasma/vacuum-pressure. The cp Ti casted by induction/centrifugation method resulted in Widmanstätten microstructural aspect, while when casted by plasma/vacuum-pressure method has feather-like aspect. For Co-Cr alloy, both methods resulted in dendritic microstructure, finer for plasma/vacuum-pressure method. The cp Ti and Co-Cr alloy seem to be affected by the cooling rate associate to the used equipment. In the chemical analysis weren't detected materials composition alterations that indicate resultant contamination for the used casting methods. Thus, however still present technical problems to be solved, both casting methods, induction/centrifugation and plasma/vacuum-pressure, allow the obtainment of satisfactory results in the RPD metal frameworks production in cp Ti.
23

Efeito de um revestimento com processamento rápido para fundição de titânio na camada de reação, porosidade interna, fluidez, rugosidade superficial e adaptação marginal de Copings /

Nogueira, Fabiane. January 2009 (has links)
Orientador: Gelson Luis Adabo / Banca: Renata Garcia Fonseca / Banca: Ricardo Faria Ribeiro / Resumo: A aplicação do titânio e ligas de titânio para implantes dentários e próteses têm crescido nos últimos anos devido às suas excelentes propriedades físicas e mecânicas. No entanto, o titânio tem alto ponto de fusão (1668ºC) e sob elevadas temperaturas, reage com elementos do ar atmosférico (oxigênio, nitrogênio, hidrogênio) e com componentes de diversos revestimentos. As reações entre o metal fundido e alguns elementos de revestimentos, principalmente fosfatados ou à base de sílica, resultam na formação de uma zona de contaminação superficial denominada "α-case". Para minimizar este problema, revestimentos contendo óxidos menos reativos, tais como Al2O3, MgO, ZrO2 e CaO, têm sido desenvolvidos. Os revestimentos especiais para fundição de titânio à base de sílica, de MgO, alumina e espinélio apresentam um tempo de processamento bastante longo (8 a 10 horas). Recentemente, foi desenvolvido um revestimento à base espinélio com processamento acelerado (Trinell - Dentaurum, Ispringen, Germany) que permite a utilização de uma técnica de secagem em forno de microondas e temperatura de aquecimento inicial do forno de 400 ºC, diminuindo o tempo de processamento para cerca de 5 horas. No entanto, não existem estudos que comprovem a eficiência deste novo revestimento. O propósito deste estudo foi avaliar o efeito do novo material Trinell (TR) na camada de reação, porosidade interna, fluidez, rugosidade superficial e adaptação marginal de estruturas fundidas em titânio, quando comparado a dois revestimentos convencionais para fundição de titânio: um revestimento fosfatado, Rematitan Plus (RP) - controle negativo e outro à base de espinélio Rematitan Ultra (RU) - controle positivo. A camada de reação foi avaliada por meio de ensaio dureza Vickers; a medida da porosidade interna foi determinada por exame radiográfico; a rugosidade superficial... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The use of titanium and titanium alloys in dental implant and prosthesis has increased in the past few years because of their excellent physical and mechanical properties. However, titanium has a high melting point (1668 ºC) and inherent reactivity with elements of atmospheric air (oxygen, nitrogen, hydrogen) and with components of several investment materials under high temperatures. The reactions between molten metal and some of the elements of phosphate-bonded and other silica-based investment materials result in the development of a surface contamination zone called "α-case". To minimize this problem, new investment materials containing less reactive oxides, such as Al2O3, MgO, ZrO2 and CaO have been developed. The commercial silica-, MgO-, Al2O3 - and spinel-based investments especially formulated to titanium casting demand a processing time in a range of 8 to 10 hours. Recently, a new short-cycle spinel-based investment (Trinell - Dentaurum, Ispringen, Germany) was developed. It has a reduced processing time - 5 hours in the furnace- because of an investment drying technique into microwaves oven followed by an initial heating in furnace at 400 °C. However, there are not studies which verify the efficiency of this new investment. The aim of this study was to evaluate the reaction layer, the internal porosity, the surface roughness, the castability and the marginal misfit of titanium castings performed with the new material, Trinell (TR), in comparison to two conventional investments for titanium castings: phosphate-bonded Rematitan Plus (RP) - negative control, and the spinel-based Rematitan Ultra (RU) - positive control. The reaction layer was evaluated by Vickers hardness; the measure of the internal porosity was determined by radiographic test; the surface roughness was measured with a surface-test analyzer, the castability was determined by the percentage of completely... (Complete abstract click electronic access below) / Mestre
24

Determination of the dimensional accuracy of epoxy resin and polyurethane dental die materials a thesis submitted in partial fulfillment ... prosthodontics ... /

Luke, Joseph T. January 1988 (has links)
Thesis (M.S.)--University of Michigan, 1988.
25

Aluminum alloy in prosthetic dentistry technics and applications : a thesis submitted in partial fulfillment ... denture prosthesis ... /

Robinson, Lucius L. January 1966 (has links)
Thesis (M.S.)--University of Michigan, 1966.
26

Determination of the dimensional accuracy of epoxy resin and polyurethane dental die materials a thesis submitted in partial fulfillment ... prosthodontics ... /

Luke, Joseph T. January 1988 (has links)
Thesis (M.S.)--University of Michigan, 1988.
27

Comparative study of silver and copper dies from elastic impression materials a thesis submitted in partial fulfillment ... crown and bridge prosthesis /

Luna, Cristóbal. January 1959 (has links)
Thesis (M.S.)--University of Michigan, 1959.
28

The accuracy of master casts fabricated from transfer impressions using the Branemark Osseointegrated Implant System a thesis submitted in partial fulfillment ... prosthodontics ... /

Humphries, Robert M. January 1988 (has links)
Thesis (M.S.)--University of Michigan, 1988.
29

Corrosion behaviour of dental casting alloys some palladium-containing alloy developments : een wetenschappelijke proeve op het gebied van de geneeskunde en tandheelkunde /

Mezger, Peter Richard. January 1989 (has links)
Thesis (doctoral)--Katholieke Universiteit te Nijmegen, 1989.
30

Corrosion behaviour of dental casting alloys some palladium-containing alloy developments : een wetenschappelijke proeve op het gebied van de geneeskunde en tandheelkunde /

Mezger, Peter Richard. January 1989 (has links)
Thesis (doctoral)--Katholieke Universiteit te Nijmegen, 1989.

Page generated in 0.089 seconds