• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 5
  • 5
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeito de um revestimento com processamento rápido para fundição de titânio na camada de reação, porosidade interna, fluidez, rugosidade superficial e adaptação marginal de Copings /

Nogueira, Fabiane. January 2009 (has links)
Orientador: Gelson Luis Adabo / Banca: Renata Garcia Fonseca / Banca: Ricardo Faria Ribeiro / Resumo: A aplicação do titânio e ligas de titânio para implantes dentários e próteses têm crescido nos últimos anos devido às suas excelentes propriedades físicas e mecânicas. No entanto, o titânio tem alto ponto de fusão (1668ºC) e sob elevadas temperaturas, reage com elementos do ar atmosférico (oxigênio, nitrogênio, hidrogênio) e com componentes de diversos revestimentos. As reações entre o metal fundido e alguns elementos de revestimentos, principalmente fosfatados ou à base de sílica, resultam na formação de uma zona de contaminação superficial denominada "α-case". Para minimizar este problema, revestimentos contendo óxidos menos reativos, tais como Al2O3, MgO, ZrO2 e CaO, têm sido desenvolvidos. Os revestimentos especiais para fundição de titânio à base de sílica, de MgO, alumina e espinélio apresentam um tempo de processamento bastante longo (8 a 10 horas). Recentemente, foi desenvolvido um revestimento à base espinélio com processamento acelerado (Trinell - Dentaurum, Ispringen, Germany) que permite a utilização de uma técnica de secagem em forno de microondas e temperatura de aquecimento inicial do forno de 400 ºC, diminuindo o tempo de processamento para cerca de 5 horas. No entanto, não existem estudos que comprovem a eficiência deste novo revestimento. O propósito deste estudo foi avaliar o efeito do novo material Trinell (TR) na camada de reação, porosidade interna, fluidez, rugosidade superficial e adaptação marginal de estruturas fundidas em titânio, quando comparado a dois revestimentos convencionais para fundição de titânio: um revestimento fosfatado, Rematitan Plus (RP) - controle negativo e outro à base de espinélio Rematitan Ultra (RU) - controle positivo. A camada de reação foi avaliada por meio de ensaio dureza Vickers; a medida da porosidade interna foi determinada por exame radiográfico; a rugosidade superficial... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The use of titanium and titanium alloys in dental implant and prosthesis has increased in the past few years because of their excellent physical and mechanical properties. However, titanium has a high melting point (1668 ºC) and inherent reactivity with elements of atmospheric air (oxygen, nitrogen, hydrogen) and with components of several investment materials under high temperatures. The reactions between molten metal and some of the elements of phosphate-bonded and other silica-based investment materials result in the development of a surface contamination zone called "α-case". To minimize this problem, new investment materials containing less reactive oxides, such as Al2O3, MgO, ZrO2 and CaO have been developed. The commercial silica-, MgO-, Al2O3 - and spinel-based investments especially formulated to titanium casting demand a processing time in a range of 8 to 10 hours. Recently, a new short-cycle spinel-based investment (Trinell - Dentaurum, Ispringen, Germany) was developed. It has a reduced processing time - 5 hours in the furnace- because of an investment drying technique into microwaves oven followed by an initial heating in furnace at 400 °C. However, there are not studies which verify the efficiency of this new investment. The aim of this study was to evaluate the reaction layer, the internal porosity, the surface roughness, the castability and the marginal misfit of titanium castings performed with the new material, Trinell (TR), in comparison to two conventional investments for titanium castings: phosphate-bonded Rematitan Plus (RP) - negative control, and the spinel-based Rematitan Ultra (RU) - positive control. The reaction layer was evaluated by Vickers hardness; the measure of the internal porosity was determined by radiographic test; the surface roughness was measured with a surface-test analyzer, the castability was determined by the percentage of completely... (Complete abstract click electronic access below) / Mestre
2

Comparação da desadaptação marginal de infra-estruturas metálicas obtidas com variações na técnica de fundição, revestimentos e material para obtenção dos padrões /

Zequetto, Michele Marques. January 2005 (has links)
Orientador: Eulália Maria Martins da Silva / Banca: Wirley Gonçalves Assunção / Banca: Maria da Glória Chiarello de Mattos / Resumo: O presente trabalho avaliou a desadaptação marginal de infra-estruturas metálicas de coroas metalo-cerâmicas obtidas com técnicas de fundição convencional (T1) e rápida (T2), utilizando para inclusão os revestimentos: aglutinado por fosfato Termocast (R1) e a base de cerâmica granulada Micro Fine 1700 (R2), confeccionando padrões em cera escultura Galileo (P1) e padrões em resina acrílica Duralay (P2), com n=56, sobre um troquel metálico. Para a construção dos padrões, utilizou-se uma matriz de silicone e realizou-se a fundição com liga de Ni-Cr. Verificou-se a desadaptação marginal por meio de um microscópio comparador digital Mitutoyo em 12 diferentes pontos de cada infra-estrutura. Os dados obtidos foram submetidos à análise de variância (ANOVA) e teste de Tukey com p<0.05, demonstrando os menores valores de desadaptação marginal e, estatisticamente similares (p<0.05), em ordem crescente, para os grupos: P2R2T2 (55,4æm), P2R1T2 (55,6æm), P2R1T1 (57,4æm), P1R2T2 (59,4æm), P1R2T1 (86æm), P1R1T1(104,4æm); e os maiores valores para P1R1T2 (166,9æm) e P2R2T1 (185,3æm). Os resultados obtidos permitiram concluir que as infra-estruturas metálicas obtidas com padrões, tanto de cera quanto de resina acrílica, apresentaram valores aceitáveis em ambas as técnicas de fundição realizadas, desde que as interações e recomendações dos fabricantes dos revestimentos sejam respeitadas. / Abstract: The present study evaluated the marginal unfit of metallic infrastructures of metallic-ceramic crowns obtained through the conventional (T1) and accelerated (T2) casting techniques, using for investing the investments: agglutinated by phosphate Termocast (R1) and the base of granulated ceramic Micro Fine 1700 (R2), making patterns in sculpture wax Galileo (P1) and patterns in acrylic resin Duralay (P2), with n=56, on a metallic die with shoulder in chamfer. For the construction of the patterns, a matrix of silicone was used and the casting was made with Ni-Cr alloy. The marginal unfit was verified through the comparing microscope Mitutoyo in 12 different points of each infrastructure. The values obtained were submitted to analysis of variance (ANOVA) and Tukey’s test with p<0.05, showed smaller values and statistically similar, in increasing order, for the groups: P2R2T2 (55,4ìm), P2R1T2 (55,6ìm), P2R1T1 (57,4ìm), P1R2T2 (59,4ìm), P1R2T1 (86ìm), P1R1T1(104,4ìm); and the largest values for P1R1T2 (166,9ìm) and P2R2T1 (185,3ìm). Taking obtained results into account, it was possible to conclude that the metallic infrastructures obtained from patterns, of wax as well as of acrylic resin, presented acceptable values of marginal fit in both casting techniques, providing the interactions and the recommendations of the investments manufacturers are respected. / Mestre
3

Avaliação da desadaptação marginal de estruturas metálicas obtidas com variações quanto aos tipos de cera e às técnicas de inclusão e fundição /

Marchiori, André Vinícius. January 2004 (has links)
Orientador: Eulália Maria Martins da Silva / Resumo: O objetivo deste trabalho foi observar o comportamento de ceras para fundições, utilizando a técnica de fundição convencional, comparando-a a técnica de fundição rápida; utilizando em ambas a expansão higroscópica de um revestimento fosfatado (All Therm, CNG Soluções Protéticas). Utilizamos duas ceras: Cera para imersão GALILEO Dip Pot Wax (Talladium Inc.) e Cera Azul para fresagem (CNG Soluções Protéticas), que foram submetidas às duas técnicas de fundição propostas. Cada grupo experimental foi composto por 12 corpos de prova e, a verificação do desajuste marginal foi realizada através de um microscópio comparador digital Mitutoyo. Cada corpo de prova foi medido em quatro pontos pré-determinados no troquel metálico. A análise dos resultados demonstrou que, com a metodologia empregada, a técnica de fundição rápida apresentou desempenho favorável, quando comparado com a técnica convencional para ambas as ceras; e a cera Azul para fresagem, na técnica rápida, foi a que apresentou menor valor médio de desadaptação (sub-adaptação). Concluímos que utilizar a expansão higroscópica do revestimento fosfatado foi uma forma de viabilizar a técnica de fundição rápida, obtendo resultados favoráveis com ambas as ceras. / Abstract: The purpose of this investigation was to observe and evaluate the behavior of dental casting wax in conventional and accelerated casting techniques, both using hygroscopic expansion of phosphate bonded investment, in order to determine which material or technique would provide better results about cervical fitting in the obtained metallic structure. The two casting waxes used, GALILEO Dip Pot Wax (Talladium Inc.) and Blue Wax of milling (CNG Soluções Protéticas), were submitted to both proposed casting techniques. Each experimental group was consisted of twelve specimens and, the assessment of marginal fitting was performed by means of a Mitutoyo comparator microscope. Each specimen was measured by using four pre-established points in stainless steel master die as references. From the employed methodology the analysis of the results showed that accelerated casting technique presented superior fitting in comparison with the conventional technique for both types of waxes. Besides, in the accelerated casting technique the Blue Wax of milling presented smaller mean value of unadaptation (underadaptation). We conclude that the use of the hygroscopic expansion of phosphate bonded investment was a way to viable the accelerated casting technique, obtaining favorable results with both casting waxes. / Mestre
4

O efeito da técnica de inclusão para fundição de titânio CP na fluidez, rusogidade, camada de reação e desajuste marginal /

Pieralini, Anelise Rodolfo Ferreira. January 2009 (has links)
Resumo: Esse estudo avaliou o efeito da tecnica de inclusao de revestimentos fosfatados nafluidez, rugosidade de superficie, camada de reacao (α-case) e adaptacao marginal de copings fundidos em Ti cp. Os padroes foram incluidos de forma convencional ou pela tecnica de inclusao experimental, na qual os padroes foram cobertos comRematitan Ultra - RU previamente a inclusao. Os revestimentos fosfatados estudados foram: Rematitan Plus (RP), Rema Exakt (RE), Castorit Super C (CA) e o revestimento a base de espinelio Rematitan Ultra (RU) foi o grupo controle. Sete grupos experimentais foram constituidos: G1: RU (controle); G2: RP; G3: RP e RU; G4: RE; G5: RE e RU; G6: CA; G7: CA e RU. Para fluidez foram feitos corpos-de-prova quadrados (15 mm X 15 mm X 0.3 mm) e a area (mm2) foi medida por um sistema analisador de imagens (n=8). Para a rugosidade de superficie as medidas (Ra) foram feitas em rugosimetro Mitutoyo (Mitutoyo SJ 400, Kanagawa, Japan) em corpos-de-prova quadrados (12 mm x 12 mm x 2 mm) n =8. A camada de reacao foi analisada por dureza Vickers, micro-analise por energia dispersiva (EDX), microscopia optica e a composicao dos revestimentos. Para dureza Vickers as medidas foram feitas em corpos-de-prova cilindricos (obtidos a partir dos sprues fundidos nos copos-de-prova para o teste de fluidez) em profundidades de 25, 50, 100, 150, 200 e 300Wm da superficie para o centro, em durometro Micromet 2100 (Buehler, Lake Bluff, Illinois, EUA) n= 8. Para a micro-analise por energia dispersiva (EDX) um equipamento EDX LINK ANALYTICAL, modelo QX 2000, com microscopio eletronico LEO (Zeiss - Germany) e detector OXFORD (Oxford Instrumentos de nano-analises Halifax Alta Rotacao WycombeBucks-HP12 3SE, UK) foram feitas em tres areas da camada de reacao (25 Wm, 75Wm e 150 Wm). Para a microscopia optica, as amostras foram polidas e limpas com solucao acida de Kroll por 20 segundos e observadas em Microscopio... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect investing technique with phosphate-bonded investment on the castability, surface of roughness, reaction layer (α-case) and marginal coping fit of CP titanium. For all analysis the specimen were coated with Rematitan Ultra - RU (experimental technique), previously to the inclusion (conventional technique) and invested into the phosphate-bonded investments: Rematitan Plus (RP), Rema Exakt (RE), Castorit Super C (CA). The seven groups studied were: G1: RU (control), G2: RP; G3: RP and RU; G4: RE; G5: RE and RU; G6: CA; G7: CA and RU. For castability, square patterns (15 mm X 15 mm X 0.3 mm) were made. The castability area (mm2) was measured by an image analysis system (n=8). The surface roughness was measured (Ra) with a rugosimeter Mitutoyo (Mitutoyo SJ 400, Kanagawa, Japan) in square resin patterns (12 mm x 12 mm x 2 mm) n =8. The reaction layer was analyzed by Vicker's hardness, Energy Dispersive X-ray microanalysis (EDX), optical microscopy and the investments composition were studied by X ray diffraction (XRD). The Vicker's hardness measurements were made sprue of castability test in cross - section at depths of 25, 50, 100, 150, 200 and 300Wm from the surface to the interior, using a durometer Micromet 2100 (Buehler, Lake Bluff, Illinois, EUA) n= 8. For Energy Dispersive X-ray microanalysis (EDX) was used an equipment EDX Link Analytical, model QX 2000, with Microscopy Electronic LEO (Zeiss - Germany) with detector Oxford (Oxford Instruments-Nano Analysis Halifax Road High WycombeBucks-HP12 3SE, UK) in three areas of reaction layer (25 Wm, 75Wm e 150 Wm). For the optical microscopy the samples were polished, cleaned and acid etched with the Kroll solution for 20 seconds and observed in an optical microscope Quimis (200 X) attached to an image analyzer Leika Qwin. For the study of the investments composition, samples with... (Complete abstract click electronic access below) / Orientador: Gelson Luís Adabo / Coorientador: Ricardo Faria Ribeiro / Banca: Sicknan Soares da Rocha / Banca: Renata Crisrina Silviera Ferracioli / Banca: João Neudenir Arioli Filho / Banca: Carlos Alberto dos Santos Cruz / Doutor
5

Cantilever em Próteses : análise da deformação de estruturas metálicas em NiCr, com diferentes configurações, em função da carga aplicada /

Alves, Luciana Mara Negrão. January 2010 (has links)
Orientador: Humberto Gennari Filho / Banca: Maria Cristina Rosifini Alves Rezende. / Banca: Ricardo Shibayama / Resumo: O êxito clínico nos tratamentos com próteses fixas implanto-suportadas com cantilever é determinado pela maneira como o estresse mecânico é transferido ao implante e ao tecido ósseo circundante sem gerar forças de grande magnitude e pelo estado de saúde dos tecidos adjacentes. Nestes tratamentos, as tensões oclusais se concentram nas extensões distais havendo uma maior incidência de fratura da estrutura, na união entre a prótese e o implante mais distal. Reconhecendo a influência do desenho da estrutura do cantilever sobre os implantes, bem como a necessidade dessas terem formatos que facilitem a higienização e manutenção do tecido periimplantar, o objetivo desse estudo será analisar a relação entre a força aplicada e a deformação ocorrida em barras para cantilever, com áreas de secção transversal em forma de triangulo, quadrada, semi lua, em L e I, através de uma Máquina de Ensaio Universal "EMIC". Serão confeccionadas 25 barras, em liga de NiCr, divididas em 5 grupos, um para cada formato de barra, com 5 corpos de prova cada um. Uma carga vertical de 200N será aplicada na extremidade do segmento de 15 mm, com velocidade de 0,5mm por minuto. As barras que suportaram uma maior carga foram as em formato quadrado, seguida pela meia lua, L, triangular sendo a em formato de I a que suporta menor força de mordida. Houve diferenças estatisticamente significantes quando comparadas as em formato quadrado em relação às outras formas e as em meia lua também com as outras formas, sendo que as em formato de L, I e triangular não apresentaram diferenças estatisticamente significantes. É importante definirmos corretamente o formato da secção transversal da barra do cantilever de uma prótese, em função de sua relação com a classe de prótese antagônica, para que não haja deformação durante a função proporcionando estruturas leves, confortáveis e com espaço suficiente para higienização / Abstract: The clinical success in treatment with implant-supported fixed prostheses with cantilever is determined by how the mechanical stress is transferred to the implant and the surrounding bone without generating forces of great magnitude and the health of tissues. In these treatments, the occlusal stress focus on the distal extensions and a higher incidence of fracture of the structure, the bond between the prosthesis and the most distal implant. Recognizing the influence of the cantilever design of the structure on implants, and the need to have these formats to facilitate the cleaning and maintenance of peri-implant tissue, the aim of this study will examine the relationship between the applied force and deformation occurred in bars for cantilever with areas of cross section in the shape of triangle, square, half moon, L and I, through a Universal Testing Machine "EMIC". 25 bars will be made in NiCr, divided into five groups, one for each bar shape, with five specimens each. 200N of a vertical load is applied at the end of the segment of 15mm with a speed of 0.5 mm per minute. The bars that bore a greater burden were square in shape, then the half moon, L, and the triangular-shaped supports that I less bite force. There were statistically significant differences when comparing the square in shape relative to other forms and in a half-moon also with other forms, and the L-shaped, triangle and I did not show statistically significant differences. It is important to properly define the shape of the cross section bar of the cantilever of a prosthesis, because of its relationship with the class of prosthesis antagonistic, so that no deformation during function, providing lightweight structures, comfortable with enough space for cleaning / Mestre

Page generated in 0.1321 seconds