Spelling suggestions: "subject:"soldagem alimentaria."" "subject:"soldagem complementaria.""
1 |
Verificação da dureza de gessos em função da compatibilidade com materiais de moldagem à base de borrachaAraujo, Rosehelene Marotta [UNESP] January 1986 (has links) (PDF)
Made available in DSpace on 2014-11-10T11:10:01Z (GMT). No. of bitstreams: 0
Previous issue date: 1986Bitstream added on 2014-11-10T11:57:18Z : No. of bitstreams: 1
000023121.pdf: 1889129 bytes, checksum: 7d413d7d31d94f2b417c51acb5fba4e0 (MD5) / O material mais empregado atualmente na construção de modelos é o gesso, que a par de técnica simples reúne condições bastante satisfatórias com relação às propriedades mecânicas, físicas e químicas. Porém, a compatibilidade relativa dos gessos com os materiais de moldagem pode comprometer as qualidades da superfície do modelo. Em nosso trabalho, estudamos a Dureza de dois tipos de gessos: tipo III (gesso pedra) e tipo IV (gesso pedra melhorado), bem como a influência do contacto com três tipos de materiais de moldagem: silicone polimerizada por condensação (Xantopren), polissulfeto (Permlastic) e silicone polimerizada por adição (Provil). Como parâmetro de comparação foi utilizado o gesso reagindo em contacto com uma superfície de vidro...... ( (Resumo completo , clicar acesso eletrônico abaixo) / Currently the most widespread material used in dies is gypsum that together with its simple technique has very satisfactory mechanical, chemical and physical properties. However, its compactibility with the impression materials can compromise the die surface quality. In our work, we studies the hardness of the two gypsum types: Type III (die stone) and type IV (improved die stone), as well as the influence of the contact with three types of impression materials: polymerized silicone for condensation (Xantopren), polysulfide (Permlastic) and polymerized silicone by addition (Provil). As comparison parameter gypsum was used in contact with a glass surface…(Complete abstract click electronic access below)
|
2 |
Verificação da dureza de gessos em função da compatibilidade com materiais de moldagem à base de borracha /Araujo, Rosehelene Marotta. January 1986 (has links)
Orientador: Francisco Pedro Monteiro da Silva Filho / Resumo: O material mais empregado atualmente na construção de modelos é o gesso, que a par de técnica simples reúne condições bastante satisfatórias com relação às propriedades mecânicas, físicas e químicas. Porém, a compatibilidade relativa dos gessos com os materiais de moldagem pode comprometer as qualidades da superfície do modelo. Em nosso trabalho, estudamos a Dureza de dois tipos de gessos: tipo III (gesso pedra) e tipo IV (gesso pedra melhorado), bem como a influência do contacto com três tipos de materiais de moldagem: silicone polimerizada por condensação (Xantopren), polissulfeto (Permlastic) e silicone polimerizada por adição (Provil). Como parâmetro de comparação foi utilizado o gesso reagindo em contacto com uma superfície de vidro...... ( (Resumo completo , clicar acesso eletrônico abaixo) / Abstract: Currently the most widespread material used in dies is gypsum that together with its simple technique has very satisfactory mechanical, chemical and physical properties. However, its compactibility with the impression materials can compromise the die surface quality. In our work, we studies the hardness of the two gypsum types: Type III (die stone) and type IV (improved die stone), as well as the influence of the contact with three types of impression materials: polymerized silicone for condensation (Xantopren), polysulfide (Permlastic) and polymerized silicone by addition (Provil). As comparison parameter gypsum was used in contact with a glass surface…(Complete abstract click electronic access below) / Mestre
|
3 |
Precisão das técnicas de moldagem para implantes angulados em maxilaVasconcelos, Juliano de Alencar [UNESP] 25 January 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0
Previous issue date: 2013-01-25Bitstream added on 2014-06-13T19:05:08Z : No. of bitstreams: 1
vasconcelos_ja_dr_arafo.pdf: 1259674 bytes, checksum: 4d4d70b38548e7cbd453a20c728f9d71 (MD5) / O assentamento passivo é um dos pré-requisitos mais importantes na reabilitação oral sobre implantes com carga imediata e na manutenção da osseointegração. Devido à importância da obtenção de passividade no sucesso de reabilitações protéticas sobre implantes, da não observância de consenso sobre as técnicas de moldagens e da ausência de trabalhos que avaliem a moldagem em reabilitações baseadas no conceito “All-on-4 - Standard”, o presente estudo analisou “in vitro” a precisão de diferentes técnicas de moldagem em reabilitações protéticas sobre implantes angulados instalados em um modelo anatômico metálico de maxila desdentada. Materiais e Métodos: Foram fatores de avaliação: tipo de moldeira (Metálica, Plástica e Guia Multifuncional); técnica de moldagem (Aberta e Fechada); métodos de união dos transferentes quadrados (sem união, unidos com bastões de resina Pattern pré-fabricados e com bastões metálicos unidos com cianoacrilato e resina Pattern); índex e índex transpalatino. Após a obtenção dos moldes (ExpressTM XT - 3M/ESPE), os modelos foram produzidos com gesso tipo IV (Fuji-Rock EP – GC America Inc. USA) sob espatulação mecânica a vácuo. Uma estrutura metálica confeccionada sobre o modelo mestre com assentamento passivo foi parafusada nos modelos obtidos. Foi utilizada uma lupa LEICA (100X) acoplada a uma câmera de vídeo colorida para captura das fendas formadas entre a infraestrutura e os análogos. Um programa (Leica QWin) foi utilizado para mensuração das fendas. Os corpos de prova foram produzidos por um pesquisador calibrado 01 e a leitura randomizada foi realizada por um pesquisador calibrado 02 (Cego). Resultados e Conclusões: O índex e índex transpalatino apresentaram as menores desadaptações. A técnica de moldeira aberta com transferentes quadrados unidos com metal... / The passivity of prosthetic components is one of the most important prerequisites in oral implant rehabilitation for maintenance of osseointegration. Due to the importance of obtaining passivity in the success of prosthetic rehabilitation on implants, nonobservance of consensus on the techniques of molding and the absence of studies assessing the molding rehabilitations based on the concept All-on-4 - Standard. This study analyzed in vitro the accuracy of different molding techniques in prosthetic rehabilitation on angled implants installed in an anatomical model of metallic edentulous maxilla. Materials and Methods: Evaluation factors were: type of tray (Metal, Plastic and Multifunctional Guide); molding technique (Open and Closed); joining methods of transferees squares (Non-union, united with canes Pattern prefabricated resin and metal sticks together with cyanoacrylate resin and Pattern resin) index and index transpalatal. After obtaining the molds (ExpressTM XT - 3M/ESPE), the models were produced with type IV gypsum (Fuji-Rock EP - GC America Inc. USA) mechanical mixing under vacuum. A metal structure fabricated on the master settlement liability was screwed with models obtained. We used a magnifying glass LEICA (100X) coupled to a color video camera to capture the cracks formed between the infrastructure and the like. A program (Leica QWin) was used to measure the cracks. The specimens were produced by a researcher calibrated 01 and randomly reading was conducted by a researcher calibrated 02 (Blind). Results and Conclusions: The index and the index showed minor transpalatal desadaptações. The technique of open tray with transferees squares together with metal, acrylic resin and cyanoacrylate provides equal results regardless of the type of mold used. There is a direct correlation between the method of union square transferees and type of tray... (Complete abstract click electronic access below)
|
4 |
Precisão das técnicas de moldagem para implantes angulados em maxila /Vasconcelos, Juliano de Alencar. January 2013 (has links)
Orientador: Francisco de Assis Mollo Junior / Coorientador: Gelson Luiz Adabo / Banca: João Neudenir Arioli filho / Banca: Eduardo Bresciani / Banca: Luiz Antonio Borelli Barros / Banca: Mauro Antonio de Arruda Nóbilo / Resumo: O assentamento passivo é um dos pré-requisitos mais importantes na reabilitação oral sobre implantes com carga imediata e na manutenção da osseointegração. Devido à importância da obtenção de passividade no sucesso de reabilitações protéticas sobre implantes, da não observância de consenso sobre as técnicas de moldagens e da ausência de trabalhos que avaliem a moldagem em reabilitações baseadas no conceito "All-on-4 - Standard", o presente estudo analisou "in vitro" a precisão de diferentes técnicas de moldagem em reabilitações protéticas sobre implantes angulados instalados em um modelo anatômico metálico de maxila desdentada. Materiais e Métodos: Foram fatores de avaliação: tipo de moldeira (Metálica, Plástica e Guia Multifuncional); técnica de moldagem (Aberta e Fechada); métodos de união dos transferentes quadrados (sem união, unidos com bastões de resina Pattern pré-fabricados e com bastões metálicos unidos com cianoacrilato e resina Pattern); índex e índex transpalatino. Após a obtenção dos moldes (ExpressTM XT - 3M/ESPE), os modelos foram produzidos com gesso tipo IV (Fuji-Rock EP - GC America Inc. USA) sob espatulação mecânica a vácuo. Uma estrutura metálica confeccionada sobre o modelo mestre com assentamento passivo foi parafusada nos modelos obtidos. Foi utilizada uma lupa LEICA (100X) acoplada a uma câmera de vídeo colorida para captura das fendas formadas entre a infraestrutura e os análogos. Um programa (Leica QWin) foi utilizado para mensuração das fendas. Os corpos de prova foram produzidos por um pesquisador calibrado 01 e a leitura randomizada foi realizada por um pesquisador calibrado 02 (Cego). Resultados e Conclusões: O índex e índex transpalatino apresentaram as menores desadaptações. A técnica de moldeira aberta com transferentes quadrados unidos com metal... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The passivity of prosthetic components is one of the most important prerequisites in oral implant rehabilitation for maintenance of osseointegration. Due to the importance of obtaining passivity in the success of prosthetic rehabilitation on implants, nonobservance of consensus on the techniques of molding and the absence of studies assessing the molding rehabilitations based on the concept "All-on-4 - Standard". This study analyzed "in vitro" the accuracy of different molding techniques in prosthetic rehabilitation on angled implants installed in an anatomical model of metallic edentulous maxilla. Materials and Methods: Evaluation factors were: type of tray (Metal, Plastic and Multifunctional Guide); molding technique (Open and Closed); joining methods of transferees squares (Non-union, united with canes Pattern prefabricated resin and metal sticks together with cyanoacrylate resin and Pattern resin) index and index transpalatal. After obtaining the molds (ExpressTM XT - 3M/ESPE), the models were produced with type IV gypsum (Fuji-Rock EP - GC America Inc. USA) mechanical mixing under vacuum. A metal structure fabricated on the master settlement liability was screwed with models obtained. We used a magnifying glass LEICA (100X) coupled to a color video camera to capture the cracks formed between the infrastructure and the like. A program (Leica QWin) was used to measure the cracks. The specimens were produced by a researcher calibrated 01 and randomly reading was conducted by a researcher calibrated 02 (Blind). Results and Conclusions: The index and the index showed minor transpalatal desadaptações. The technique of open tray with transferees squares together with metal, acrylic resin and cyanoacrylate provides equal results regardless of the type of mold used. There is a direct correlation between the method of union square transferees and type of tray... (Complete abstract click electronic access below) / Doutor
|
5 |
Avaliação da adaptação marginal de copings cerâmicos obtidos por diferentes métodos de moldagem /Pinto, Tatiana Saretta Ferreira. January 2018 (has links)
Orientador: Rodrigo Máximo de Araújo / Banca: Vinícius Anéas Rodrigues / Banca : Eduardo Galera da Silva / Resumo: O objetivo desse estudo foi avaliar a adaptação marginal de copings cerâmicos obtidos pelos métodos de moldagem convencional e escaneamento. Os modelos foram separados em 3 grupos para avaliação e todas as coroas foram confeccionadas sobre um modelo mestre previamente fabricado em CoCr. Grupo 1: Com o auxílio de uma moldeira individual cilíndrica de acrílico foram reproduzidas 10 moldagens com silicona de adição (Panasil) no modelo mestre pela técnica de moldagem dupla e replicados dez modelos físicos em gesso pedra Fuji Rock.Sobre esses modelos foi realizado o enceramento dos copings, confecção dos sprues de cera e sobre eles foi realizada a injeção da cerâmica Grupo 2: foram realizadas 10 moldagens diretas com scanner extraoral (Swing Dental Scanner) no modelo mestre. As imagens foram obtidas através do software Exocad e copings em IPS-Emax CAD foram confeccionados em fresadora (Ceramill Motion 2) para posterior sinterização da cerâmica. Grupo 3: foram realizadas 10 moldagens diretas com scanner intraoral (CEREC Bluecam) no modelo mestre. As imagens foram obtidas através do software Exocad. Copings em IPS-Emax CAD foram confeccionados em fresadora (Ceramill Motion 2) para posterior sinterização da cerâmica. Os copings de cerâmica não foram cimentados no modelo mestre, apenas posicionados e mantidos com pressão constante de 1,4 a 1,5 kg durante a medição, com a ajuda de um delineador adaptado para esse trabalho, onde oito pontos eletivos foram usados como referência para med... (Resumo completo, clicar acesso eletrônico abaixo) / The objective of the study was to evaluate the marginal adaptation of ceramic crowns obtained by conventional molding and scanning methods. The models were separated into 3 groups for evaluation and all the crowns were made on a master model previously manufactured in CoCr. For group 1: With the aid of a single cylindrical acrylic tray the master model was molded 10 times with Panasil in the master model by the technique of double molding and replicated ten physical models in stone gypsum Fuji Rock. On these models was done the waxing of the copings, making the sprues of wax and on them was carried out the injection of the ceramics In group 2, 10 direct impressions were performed with the Swing Dental Scanner (Korea) extra oral scanner in the master model. The images were obtained through the software Exocad (GmbH) and copings in IPS-Emax CAD were made in the Ceramill Motion 2 (Amanngirrbach) mill for subsequent sintering of the ceramics. In group 3, 10 direct impressions were performed with the CEREC Bluecam intraoral scanner (Sirona Dental Systems) in the master model. The images were obtained through the Exocad (GmbH) software. IPS-Emax CAD copings were made in the Ceramill Motion 2 (Amanngirrbach) mill for subsequent sintering of the ceramic. Ceramic copings were not cemented in the master model, only positioned and maintained with a constant pressure of 1.4 to 1.5 kg during the measurement, with the aid of an eyeliner adapted for this work, where eight elective points were used as reference to measure the vertical distance between the end line of the master model and the end line of the copings. The margin at each point was measured 3 times with stereo microscope Discovery V20 (ZEISS). The mean was calculated and submitted to the ANOVA variance test "with a significance level of 5% and the following results were obtained: 66.15μm for group 1; 67.48μm for group ...(Resumo completo, clicar acesso eletrônico abaixo) / Mestre
|
6 |
Avaliação da desadaptação marginal de estruturas metálicas obtidas com variações quanto aos tipos de cera e às técnicas de inclusão e fundição /Marchiori, André Vinícius. January 2004 (has links)
Orientador: Eulália Maria Martins da Silva / Resumo: O objetivo deste trabalho foi observar o comportamento de ceras para fundições, utilizando a técnica de fundição convencional, comparando-a a técnica de fundição rápida; utilizando em ambas a expansão higroscópica de um revestimento fosfatado (All Therm, CNG Soluções Protéticas). Utilizamos duas ceras: Cera para imersão GALILEO Dip Pot Wax (Talladium Inc.) e Cera Azul para fresagem (CNG Soluções Protéticas), que foram submetidas às duas técnicas de fundição propostas. Cada grupo experimental foi composto por 12 corpos de prova e, a verificação do desajuste marginal foi realizada através de um microscópio comparador digital Mitutoyo. Cada corpo de prova foi medido em quatro pontos pré-determinados no troquel metálico. A análise dos resultados demonstrou que, com a metodologia empregada, a técnica de fundição rápida apresentou desempenho favorável, quando comparado com a técnica convencional para ambas as ceras; e a cera Azul para fresagem, na técnica rápida, foi a que apresentou menor valor médio de desadaptação (sub-adaptação). Concluímos que utilizar a expansão higroscópica do revestimento fosfatado foi uma forma de viabilizar a técnica de fundição rápida, obtendo resultados favoráveis com ambas as ceras. / Abstract: The purpose of this investigation was to observe and evaluate the behavior of dental casting wax in conventional and accelerated casting techniques, both using hygroscopic expansion of phosphate bonded investment, in order to determine which material or technique would provide better results about cervical fitting in the obtained metallic structure. The two casting waxes used, GALILEO Dip Pot Wax (Talladium Inc.) and Blue Wax of milling (CNG Soluções Protéticas), were submitted to both proposed casting techniques. Each experimental group was consisted of twelve specimens and, the assessment of marginal fitting was performed by means of a Mitutoyo comparator microscope. Each specimen was measured by using four pre-established points in stainless steel master die as references. From the employed methodology the analysis of the results showed that accelerated casting technique presented superior fitting in comparison with the conventional technique for both types of waxes. Besides, in the accelerated casting technique the Blue Wax of milling presented smaller mean value of unadaptation (underadaptation). We conclude that the use of the hygroscopic expansion of phosphate bonded investment was a way to viable the accelerated casting technique, obtaining favorable results with both casting waxes. / Mestre
|
7 |
Avaliação das alterações dimensionais em modelos de gesso para protese total por meio de medição tridimensional em função de materiais e tecnicas de moldagem / Avaliation of dimensional changes in complete dentures stone cast by means of tri-dimensional measurements, in relation to materials and impression methodsMonteiro, Wildes da Costa 16 May 2005 (has links)
Orientador: Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T11:55:19Z (GMT). No. of bitstreams: 1
Monteiro_WildesdaCosta_D.pdf: 6985087 bytes, checksum: dab5ef3ae95601eac48a0d542f0cf87f (MD5)
Previous issue date: 2005 / Resumo: O objetivo deste estudo foi analisar por meio de medições tridimensionais, as alterações dimensionais que ocorrem nos modelos de gesso utilizados na confecção de prótese total, em função de diferentes materiais para moldagem: silicone, alginato e godiva equalizada com alginato. Foram confeccionados 45 modelos de gesso tipo IV, (n=15) construídos a partir de moldes obtidos de um modelo padrão metálico de alumínio, onde foram colocados 7 parafusos com 3,5 mm de diâmetro, para estabelecer pontos referenciais das distâncias a serem mensuradas. Esses pontos referenciais permitiram criar segmentos para o cálculo do volume e da área gerados nas figuras representativas dos modelos de gesso, permitindo avaliar a estabilidade dimensional dos modelos em gesso por meio de medições tridimensionais. No CETEF os modelos de gesso foram submetidos às medições tridimensionais no aparelho Mitutoyo, modelo BLN 710, equipado com cabeça de medição Renishaw PH9 e apalpador TP200 com esfera de 1mm de diâmetro, para as seguintes etapas: 1- transferência das coordenadas tridimensionais para o programa Mechanical Desktop; realização dos desenhos bidimensionais; medição dos seguimentos que compõem cada figura desenhada de cada desenho; realização dos desenhos tridimensionais; cálculo do volume e da área projetada utilizando a malha de elementos finitos e confecção de uma planilha de cálculo para cada material de moldagem; tratamento estatístico dos dados e determinação matemática das variações e das coordenadas x, y e z dos comprimentos de cada um dos segmentos, dos perímetros e das áreas de cada figura dos quarenta e cinco modelos. 2- lançamento dos dados nas planilhas de cálculo; tratamento estatístico dos dados e determinação matemática das variações e das coordenadas x, y e z dos comprimentos de cada um dos segmentos, dos perímetros e das áreas de cada figura. 3- apresentação tridimensional das variações dimensionais encontradas nos modelos; transferência das variações das coordenadas do grupo de modelos de cada material, em relação ao modelo padrão, para o software de desenho 3D ¿ Mechanical Desktop; geração das figuras para visualização das variações e elaboração de relatório técnico. Os resultados foram submetidos à média matemática simples da dispersão ou variação dos dados, que é o grau no qual os dados numéricos da amostra tendem a dispersar-se em torno de um valor médio. Foi utilizado neste trabalho o cálculo do desvio padrão simples. Os moldes feitos com silicone por adição produziram modelos com menor variação dimensional (capacidade de repetitibilidade) quando comparados aos modelos obtidos com moldes de alginato e godiva equalizada com alginato. O alginato produziu modelos com grande fidelidade de cópias em função da matriz metálica / Abstract: The purpose of this study was to analyze, through three-dimensional measurements, the dimensional changes in casts of stone used to make complete dentures, in function of different materials for impression: addition reaction silicone, alginate and impression compound reline with alginate. The casts of stone type IV were made from molds obtained from a metallic standard die of aluminum. In this metallic die were put seven screws with 3,5mm diameter, to establish referential points of the measured distances. The referential points allowed creating segments
for the calculation of the area and volume in the representative drawings generated for the stone casts. The procedure allows evaluating the dimensional stability through three-dimensional measurements. In CETEF the stone die were measured with three-dimensional equipment Mitutoyo, model BLN 710, equipped with measurement head Renishaw PH9 and feeler TP200 with sphere of 1mm of diameter, for the stages: 1- Transfer of the three-dimensional coordinates for the program Mechanical Desktop; generation of the two-dimensional drawings; measurement of the segments that compose each drawing; generation of the three-dimensional drawings; projected area determination and volume calculation using the finite elements net; making of a calculation spread sheet for each impression material; statistical treatment of the data and mathematical determination of the variations in the x, y and z coordinates in the lengths of each segments, in the perimeters and in the areas of each drawing of the forty five casts. 2 - Insertion of the data in the calculation spread sheets; statistical treatment of the data and mathematical determination of the variations and in the x, y and z coordinates in the lengths of each one of the segments, in the perimeters and of the areas of each drawing. 3 - Three-dimensional presentation of the dimensional variations found in the models; transfer of the variations of the coordinates of the group of models of each material, for the software of 3D drawing ¿ Mechanical Desktop; generation of the drawings for visualization of the variations and elaboration of technical report. The results were submitted to the simple mathematics medium of the dispersion or variation of the data, that it is the degree, in which the numeric data of the sample tend to disperse around a medium value. It was used in this work the calculation of the simple standard deviation. The molds made with addition reaction silicone produced casts with smaller dimensional variation, when compared to the casts obtained with alginate or impression compound reline with alginate. The silicone presented larger capacity to repeat generated copies of the molds, from the standard die. The cast made with addition reaction silicone presented small variation among themselves when compared to the standard metallic die / Doutorado / Protese Dental / Doutor em Clínica Odontológica
|
8 |
Avaliação da desadaptação marginal de estruturas metálicas obtidas com variações quanto aos tipos de cera e às técnicas de inclusão e fundiçãoMarchiori, André Vinícius [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0
Previous issue date: 2004Bitstream added on 2014-06-13T20:18:36Z : No. of bitstreams: 1
marchiori_av_me_araca.pdf: 946522 bytes, checksum: ed4cd9e55e14d7d9431de58e44b8da02 (MD5) / Cng Solucoes Proteticas / Talladium do Brasil / O objetivo deste trabalho foi observar o comportamento de ceras para fundições, utilizando a técnica de fundição convencional, comparando-a a técnica de fundição rápida; utilizando em ambas a expansão higroscópica de um revestimento fosfatado (All Therm, CNG Soluções Protéticas). Utilizamos duas ceras: Cera para imersão GALILEO Dip Pot Wax (Talladium Inc.) e Cera Azul para fresagem (CNG Soluções Protéticas), que foram submetidas às duas técnicas de fundição propostas. Cada grupo experimental foi composto por 12 corpos de prova e, a verificação do desajuste marginal foi realizada através de um microscópio comparador digital Mitutoyo. Cada corpo de prova foi medido em quatro pontos pré-determinados no troquel metálico. A análise dos resultados demonstrou que, com a metodologia empregada, a técnica de fundição rápida apresentou desempenho favorável, quando comparado com a técnica convencional para ambas as ceras; e a cera Azul para fresagem, na técnica rápida, foi a que apresentou menor valor médio de desadaptação (sub-adaptação). Concluímos que utilizar a expansão higroscópica do revestimento fosfatado foi uma forma de viabilizar a técnica de fundição rápida, obtendo resultados favoráveis com ambas as ceras. / The purpose of this investigation was to observe and evaluate the behavior of dental casting wax in conventional and accelerated casting techniques, both using hygroscopic expansion of phosphate bonded investment, in order to determine which material or technique would provide better results about cervical fitting in the obtained metallic structure. The two casting waxes used, GALILEO Dip Pot Wax (Talladium Inc.) and Blue Wax of milling (CNG Soluções Protéticas), were submitted to both proposed casting techniques. Each experimental group was consisted of twelve specimens and, the assessment of marginal fitting was performed by means of a Mitutoyo comparator microscope. Each specimen was measured by using four pre-established points in stainless steel master die as references. From the employed methodology the analysis of the results showed that accelerated casting technique presented superior fitting in comparison with the conventional technique for both types of waxes. Besides, in the accelerated casting technique the Blue Wax of milling presented smaller mean value of unadaptation (underadaptation). We conclude that the use of the hygroscopic expansion of phosphate bonded investment was a way to viable the accelerated casting technique, obtaining favorable results with both casting waxes.
|
9 |
Influencia do conteudo volumetrico das particulas de cargas nas propriedades mecanicas de diferentes materiais de moldagem / Mechanical properties of impression materials by volumetric filler contentCarlo, Hugo Lemes 24 July 2008 (has links)
Orientadores: Mario Alexandre Coelho Sinhoreti, Carlos Jose Soares / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-11T16:18:48Z (GMT). No. of bitstreams: 1
Carlo_HugoLemes_D.pdf: 4484901 bytes, checksum: b6c246e6e05cdf7633210adfa7b73c84 (MD5)
Previous issue date: 2008 / Resumo: Baseado no entendimento incompleto de como o conteúdo de partículas de carga influencia nas propriedades mecânicas dos materiais de moldagem este estudo avaliou quantitativa e qualitativamente o conteúdo de partículas de carga inorgânicas presente em cinco marcas comerciais de alginatos (Jeltrate; Jeltrate Plus, Jeltrate Chromatic Ortho, Hydrogum e Ezact Krom) e nove marcas comerciais de siliconas de adição e/ou condensação nas consistências massa e/ou fluida (Clonage, Elite HD+ Light Body, Express Light Body, Flexitime, Optosil P Confort/Xantopren VL Plus, Oranwash L, Reprosil A+, Silon 2 APS e Virtual Extra Light Body). Foram realizados testes para determinar recuperação elástica e deformação sob compressão dos alginatos e dos elastômeros e estabelecer, dessa forma, uma correlação entre os resultados para partículas de carga e os testes mecânicos. O conteúdo volumétrico das partículas de carga foi determinado pesando-se as amostras submersas em água antes e após a queima das mesmas durante 3h a 450°C (alginatos) e a 600°C (siliconas). Quantidades determinadas de materiais não polimerizados foram lavadas em acetona e clorofórmio e recobertas com ouro para avaliação da morfologia e tamanho das partículas em M.E.V. A composição foi determinada por EDX. A recuperação elástica e a deformação sob compressão foram determinadas de acordo as especificações ? 1563 (alginatos) e 4823 (elastômeros) da ISO. O alginatos Jeltrate e Jeltrate Plus apresentaram os maiores valores médios para quantidade volumétrica de partículas de carga (%) enquanto o material Hydrogum apresentou os menores valores. A silicone de adição Flexitime Easy Putty apresentou os maiores valores de quantidade volumétrica de partículas, enquanto que a silicone de condensação Xantopren VL Plus apresentou os menores. As partículas de carga dos alginatos apresentaram-se, de forma geral, como objetos esféricos e com perfurações. O material Hydrogum apresentou forma de bastões cilíndricos e perfurados. As siliconas apresentaram morfologias variadas ¿ partículas trituradas, esféricas, esferóides, bastões cilíndricos perfurados e bastões misturados a partículas
usinadas. O alginato Ezact Krom apresentou os maiores valores médios de tamanho de partícula, enquanto que o alginato Hydrogum as menores. A silicone de condensação Clonage massa apresentou os maiores valores médios de tamanho de partícula, enquanto a silicone de adição Elite HD os menores. A análise da composição das partículas apresentou o silício como o elemento em maior quantidade. Com relação aos resultados de recuperação elástica, o alginato Ezact Krom e as siliconas Reprosil A+ massa e Flexitime fluida apresentaram os maiores valores de recuperação elástica, enquanto o alginato Jeltrate Plus e as siliconas Optosil P Confort e Clonage fluida apresentaram os menores. Os resultados de deformação sob compressão foram maiores para o alginato Jeltrate
Plus e para as siliconas Silon 2 APS massa e fluida. Os menores resultados foram apresentados pelo alginato Ezact Krom e as siliconas Reprosil A+ massa e Xantopren VL Plus. Todos os materiais estão em conformidade com a norma ISO ?1563, mas nem todos estão em relação à norma ?4823 / Abstract: Based on the incomplete understanding on how filler features influence the properties of elastomeric impression materials, the purpose of this study was to determine the inorganic filler fraction and size of five commercially available alginates (Jeltrate; Jeltrate Plus, Jeltrate Chromatic Ortho, Hydrogum e Ezact Krom) and nine addition/condensation silicones using the putty/light consistence (Clonage, Elite HD+ Light Body, Express Light Body, Flexitime, Optosil P Confort/Xantopren VL Plus, Oranwash L, Reprosil A+, Silon 2 APS e Virtual Extra Light Body). A SEM/EDX analysis was done to qualitatively characterize the materials. Soon afterwards elastic recovery and strain in compression of the alginates and some the silicones was carried. The inorganic particles volumetric fractions were accessed by weighing a previously determined mass of each material in water before and after burning samples for 3 hours at 450ºC (alginates) and 600ºC (silicones). Unsettled materials were soaked in acetone and chloroform and sputter-coated with gold for SEM evaluation of fillers¿ morphology and size. The filler composition was determined by EDX. Elastic recovery and strain in compression tests were conducted according to ISO specification number 1563 and 4823. Jeltrate and Jeltrate Plus presented the highest mean values of percentage content of inorganic particles in volume, while Jeltrate Chromatic Ortho presented the lowest values. Flexitime Easy Putty was the silicone with the highest mean value, while Xantopren VL Plus had the lowest value. The alginate fillers presented a circular appearance with helical form and various perforations. Hydrogum fillers looked like cylindrical, perforated sticks. SEM pictures of the silicone inorganic particles showed numerous morphologies ¿ lathe-cut, spherical, spherical-like, sticks, and sticks mixed to lathe-cut powder. Ezact Krom was the alginate with the highest values for diameter size, while Hydrogum had the lowest. Clonage Putty showed the highest values, while Elite HD+ Light Body presented the lowest
values. The component in higher concentration in the materials is silicon. The alginate Ezact Krom, and the addition cure silicones Reprosil A+ putty and Flexitime Correct Flow had the highest mean values of elastic recovery, while the alginate Jeltrate Plus and the condensation cured silicones Optosil P Confort and Clonage Putty presented the lowest values. Strain in compression test showed the alginate Jeltrate Plus and the condensation cured silicones Silon 2APS Putty and Fluid as the materials with the highest values. The alginate Ezact Krom and the silicones Reprosil A+ Putty and Xantopren VL Plus had lowest values. All materials are in conformity with the requirements of ISO specification number 1563, but not all materials are in conformity with the requirements of ISO specification number 4823 / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
|
Page generated in 0.331 seconds