• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • Tagged with
  • 18
  • 18
  • 18
  • 17
  • 16
  • 16
  • 10
  • 9
  • 7
  • 7
  • 7
  • 6
  • 6
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

"Estudo comparativo de dois métodos utilizados na fundição de titânio cp" / Comparative study of two cp Ti casting methods.

Rodrigues, Renata Cristina Silveira 29 April 2005 (has links)
Ao longo da última década, vários trabalhos têm destacado as vantagens do titânio e suas ligas e estudado a possibilidade de utilização para a confecção de estruturas metálicas de prótese parcial removível. Apesar das vantagens, o processo de fundição ainda apresenta problemas, limitando o uso do titânio. O objetivo deste estudo foi avaliar a influência de dois métodos de fundição, sobre microestrutura, microdureza, porosidade e força de retenção de grampos de PPR, fundidos em Co-Cr (controle) e titânio comercialmente puro (Ti cp). Foram utilizados os seguintes métodos: 1- arco voltaico (plasma) sob vácuo e pressão de argônio, com injeção do metal fundido por vácuo-pressão, e 2- indução sob vácuo e atmosfera de argônio, com injeção do metal fundido por centrifugação. Para análise da força de retenção foram confeccionadas estruturas metálicas com grampos circunferenciais sob retenção de 0,25; 0,50 e 0,75 mm, submetidas a ciclos de inserção/remoção simulando o uso por um período de 5 anos. Previamente ao ensaio de simulação, os corpos-de-prova foram radiografados em unidade laboratorial de raios X. Para o ensaio de microdureza Vickers e microestrutura foram confeccionados discos, com 5 mm de diâmetro e 2 mm de espessura, polidos metalograficamente. Os resultados mostraram que os métodos de fundição interferem nas características dos materiais estudados. As peças em titânio cp fundidas por plasma/vácuo-pressão apresentaram maior número de porosidades (50%) do que as fundidas por indução/centrifugação (16,66%). Para as peças fundidas em liga de Co-Cr, segundo a metodologia empregada, não foi possível observar a ocorrência de porosidades. As peças fundidas por plasma/vácuo-pressão apresentaram maior flexibilidade e as fundidas por indução/centrifugação apresentaram maior rigidez. Conseqüentemente, as forças de retenção foram, em geral, maiores para os corpos-de-prova obtidos por indução/centrifugação do que para aqueles obtidos por plasma/vácuo-pressão, com exceção da condição experimental de retenção 0,75 mm. Os corpos-de-prova fundidos por indução/centrifugação apresentaram, tanto para o Ti cp quanto para a liga de Co-Cr, maiores valores de microdureza Vickers do que os fundidos por plasma/vácuo-pressão. O Ti cp fundido pelo método de indução/centrifugação resultou em microestrutura de aspecto Widmanstätten, enquanto quando fundido pelo método de plasma/vácuo-pressão tem aspecto metalográfico tipo feather-like. Para a liga de Co-Cr, ambos os métodos resultaram em microestrutura dendrítica, mais fina para o método de plasma/vácuo-pressão. O Ti cp e a liga de Co-Cr, parecem ser afetados pela velocidade de resfriamento associada ao equipamento utilizado. Na análise química não foram detectadas alterações de composição dos materiais que indicassem contaminação resultante dos métodos de fundição utilizados. Assim, embora ainda apresentem problemas técnicos a serem resolvidos, ambos os métodos de fundição, indução/centrifugação e plasma/vácuo-pressão, permitem a obtenção de resultados satisfatórios na produção de estruturas metálicas de PPR em Ti cp. / Along the last decade, several jobs have been highlighting the advantages of titanium and titanium alloys and studied the possible utilization for removable partial dentures (RPD) metal frameworks confection. Although advantages, the cast process still presents problems, limiting the titanium use. The objective of this study was to evaluate the influence of two casting methods, on microstructure, microhardness, porosity and retention force of RPD clasps, casted in Co-Cr alloy (control) and commercially pure titanium (cp Ti). The cast methods used were: 1- voltaic arc (plasma) under vacuum and argon pressure, with molten metal injection by vacuum-pressure, and 2- induction under vacuum and argon atmosphere, with molten metal injection by centrifugation. For retention force analysis were made metal frameworks with circumferential clasps under retention of 0.25; 0.50 and 0.75 mm, submitted to insertion/removal cycles, simulating a 5 years use of a metal framework. Previously to the simulation test, the samples were radiographed in a laboratorial unit to verify the porosities occurrence. For Vickers microhardness test and microstructure analysis, disks with 5mm diameter and 2 mm thickness were made. The results showed that the casting methods interfere in the characteristics of studied materials. The cp Ti pieces casted by plasma/vacuum-pressure presents larger porosities number (50%) than that casted by induction/centrifugation (16.66%). For the pieces casted in Co-Cr alloy, according to the used methodology, wasn't possible to observe the occurrence of porosities. The pieces casted by plasma/vacuum-pressure presents larger flexibility and that casted by induction/centrifugation present larger rigidity. Consequently, the retention forces were, in general, larger for the samples obtained by induction/centrifugation than for those obtained by plasma/vacuum-pressure, except for the experimental condition with 0.75 mm retention. The samples casted by induction/centrifugation present, as for cp Ti as for Co-Cr alloy, larger Vickers microhardness values Vickers than that casted by plasma/vacuum-pressure. The cp Ti casted by induction/centrifugation method resulted in Widmanstätten microstructural aspect, while when casted by plasma/vacuum-pressure method has feather-like aspect. For Co-Cr alloy, both methods resulted in dendritic microstructure, finer for plasma/vacuum-pressure method. The cp Ti and Co-Cr alloy seem to be affected by the cooling rate associate to the used equipment. In the chemical analysis weren't detected materials composition alterations that indicate resultant contamination for the used casting methods. Thus, however still present technical problems to be solved, both casting methods, induction/centrifugation and plasma/vacuum-pressure, allow the obtainment of satisfactory results in the RPD metal frameworks production in cp Ti.
2

Influência das técnicas de cimentação, fundição em monobloco e brasagem na adaptação de componentes protéticos de próteses sobre implantes fundidos em Cr-Co

AQUINO, Elane Barroso de 29 May 2006 (has links)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-02-13T14:48:36Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_InfluenciaTecnicasCimentacao.pdf: 2231302 bytes, checksum: 96c5275eff5e84fbcf6c5e6cf2618bd6 (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2014-04-28T15:19:51Z (GMT) No. of bitstreams: 2 Dissertacao_InfluenciaTecnicasCimentacao.pdf: 2231302 bytes, checksum: 96c5275eff5e84fbcf6c5e6cf2618bd6 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2014-04-28T15:19:51Z (GMT). No. of bitstreams: 2 Dissertacao_InfluenciaTecnicasCimentacao.pdf: 2231302 bytes, checksum: 96c5275eff5e84fbcf6c5e6cf2618bd6 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Previous issue date: 2006 / O presente estudo avaliou a adaptação da interface implante/componente protético, utilizando pilares Micro-Units com seus respectivos copings acrílicos (Conexão Sistemas de Prótese – São Paulo – SP – Brasil) e UCLAs (Conexão Sistemas de Prótese – São Paulo – SP – Brasil), por meio de três diferentes técnicas: cimentação (grupo 1), fundição em monobloco (grupo 2) e fundição e brasagem (grupo 3). Foram confeccionados 20 corpos - de- prova, cada corpo apresentava 3 componentes protéticos e duas barras que os unia. Foram utilizados 30 componentes protéticos Micro-Units, 30 copings acrílicos dos Micro-Units (Conexão Sistemas de Prótese – São Paulo – SP – Brasil) e 30 UCLAs (Conexão Sistemas de Prótese – São Paulo – SP – Brasil). Também foram usadas 40 barras cilíndricas de 2mm de diâmetro, obtidas a partir de uma matriz. Cada grupo tinha 10 corpos-de-prova. Os corpos-deprova foram divididos inicialmente em dois grupos. No grupo 1 foram utilizados componentes protéticos Micro-Units e seus respectivos copings acrílicos, os quais foram fundidos em Cr-Co, parafusados e cimentados sobre os Micro-Units. No grupo 2 os componentes protéticos calcináveis (UCLA), foram fundidos em monobloco utilizando-se Cr-Co. Posteriormente foi realizada a separação das peças em monobloco do grupo 2, o qual passou a ser chamado de grupo 3, sendo então submetido à brasagem. Todos os grupos foram mensurados em um estereomicroscópio (SZX12, Olympus, Japan) com aumento de 60X em relação à adaptação, antes e após os procedimentos para a obtenção das estruturas, através de cada técnica. Os resultados mostraram que o grupo 1 apresentou uma adaptação estatisticamente superior, inicial (0,000μm) e final (3,588μm), em relação aos grupos 2 (9,252μm e 325,259μm) e 3 (0,874μm e 121,592μm). O grupo 3 apresentou uma melhora significativa em relação ao grupo 2. A técnica com melhor adaptação foi a cimentação. / The present study evaluated the adaptation from the interface implant/abutment using Micro-Units, with their acrylic copings (Conexão Sistemas de Prótese – São Paulo – SP – Brasil), and UCLAs (Conexão Sistemas de Prótese – São Paulo – SP – Brasil) pillars throw three different techniques: cementation (group 1), one-piececasting (group 2) and casting plus brazing (group 3). It was made 20 specimens; each one had three abutments jointed by two bars. It was used 30 Micro-Units , 30 acrylic copings of Micro-Units (Conexão Sistemas de Prótese – São Paulo – SP – Brasil) and 30 UCLAs (Conexão Sistemas de Prótese – São Paulo – SP – Brasil). Also were used 40 cylindrical bars with 2mm of diameter, obtained from one matrix. Each group had 10 specimens. The specimens were initially divided in two groups. Group 1 used Micro-Units abutments, with their acrylic copings which were casting in cr-co, screwed and cemented over Micro-Units. Group 2 had abutments UCLA in plastic, which were made in one-piece casting using Cr-Co. Group 2 afterwards, was cute and was called group 3, than was brazing. All groups were measured for adaptation, with stereomicroscope (SZX12, Olympus, Japan), 60X increase, before and after the procedures to obtain the structures, by each technique. The results show that group 1 is statistically superior in adaptation, at first (0,000μm) and at last (3,588μm), in relation to group 2 (9,52μm e 325,259μm) and 3 (0,874μm e 121,592μm). Group 3 shows a significant improvement in relation to group 2. The cementation technique shows the best adaptation.
3

O efeito da técnica de inclusão para fundição de titânio CP na fluidez, rusogidade, camada de reação e desajuste marginal

Pieralini, Anelise Rodolfo Ferreira [UNESP] 24 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-24Bitstream added on 2014-06-13T19:05:05Z : No. of bitstreams: 1 pieralini_arf_dr_arafo.pdf: 663939 bytes, checksum: 42cf2061e12d479c5f2e5d6d6429b27f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Esse estudo avaliou o efeito da tecnica de inclusao de revestimentos fosfatados nafluidez, rugosidade de superficie, camada de reacao (α-case) e adaptacao marginal de copings fundidos em Ti cp. Os padroes foram incluidos de forma convencional ou pela tecnica de inclusao experimental, na qual os padroes foram cobertos comRematitan Ultra – RU previamente a inclusao. Os revestimentos fosfatados estudados foram: Rematitan Plus (RP), Rema Exakt (RE), Castorit Super C (CA) e o revestimento a base de espinelio Rematitan Ultra (RU) foi o grupo controle. Sete grupos experimentais foram constituidos: G1: RU (controle); G2: RP; G3: RP e RU; G4: RE; G5: RE e RU; G6: CA; G7: CA e RU. Para fluidez foram feitos corpos-de-prova quadrados (15 mm X 15 mm X 0.3 mm) e a area (mm2) foi medida por um sistema analisador de imagens (n=8). Para a rugosidade de superficie as medidas (Ra) foram feitas em rugosimetro Mitutoyo (Mitutoyo SJ 400, Kanagawa, Japan) em corpos-de-prova quadrados (12 mm x 12 mm x 2 mm) n =8. A camada de reacao foi analisada por dureza Vickers, micro-analise por energia dispersiva (EDX), microscopia optica e a composicao dos revestimentos. Para dureza Vickers as medidas foram feitas em corpos-de-prova cilindricos (obtidos a partir dos sprues fundidos nos copos-de-prova para o teste de fluidez) em profundidades de 25, 50, 100, 150, 200 e 300Wm da superficie para o centro, em durometro Micromet 2100 (Buehler, Lake Bluff, Illinois, EUA) n= 8. Para a micro-analise por energia dispersiva (EDX) um equipamento EDX LINK ANALYTICAL, modelo QX 2000, com microscopio eletronico LEO (Zeiss - Germany) e detector OXFORD (Oxford Instrumentos de nano-analises Halifax Alta Rotacao WycombeBucks-HP12 3SE, UK) foram feitas em tres areas da camada de reacao (25 Wm, 75Wm e 150 Wm). Para a microscopia optica, as amostras foram polidas e limpas com solucao acida de Kroll por 20 segundos e observadas em Microscopio... / This study evaluated the effect investing technique with phosphate-bonded investment on the castability, surface of roughness, reaction layer (α-case) and marginal coping fit of CP titanium. For all analysis the specimen were coated with Rematitan Ultra - RU (experimental technique), previously to the inclusion (conventional technique) and invested into the phosphate-bonded investments: Rematitan Plus (RP), Rema Exakt (RE), Castorit Super C (CA). The seven groups studied were: G1: RU (control), G2: RP; G3: RP and RU; G4: RE; G5: RE and RU; G6: CA; G7: CA and RU. For castability, square patterns (15 mm X 15 mm X 0.3 mm) were made. The castability area (mm2) was measured by an image analysis system (n=8). The surface roughness was measured (Ra) with a rugosimeter Mitutoyo (Mitutoyo SJ 400, Kanagawa, Japan) in square resin patterns (12 mm x 12 mm x 2 mm) n =8. The reaction layer was analyzed by Vicker’s hardness, Energy Dispersive X-ray microanalysis (EDX), optical microscopy and the investments composition were studied by X ray diffraction (XRD). The Vicker’s hardness measurements were made sprue of castability test in cross – section at depths of 25, 50, 100, 150, 200 and 300Wm from the surface to the interior, using a durometer Micromet 2100 (Buehler, Lake Bluff, Illinois, EUA) n= 8. For Energy Dispersive X-ray microanalysis (EDX) was used an equipment EDX Link Analytical, model QX 2000, with Microscopy Electronic LEO (Zeiss - Germany) with detector Oxford (Oxford Instruments-Nano Analysis Halifax Road High WycombeBucks-HP12 3SE, UK) in three areas of reaction layer (25 Wm, 75Wm e 150 Wm). For the optical microscopy the samples were polished, cleaned and acid etched with the Kroll solution for 20 seconds and observed in an optical microscope Quimis (200 X) attached to an image analyzer Leika Qwin. For the study of the investments composition, samples with... (Complete abstract click electronic access below)
4

Efeito de um revestimento com processamento rápido para fundição de titânio na camada de reação, porosidade interna, fluidez, rugosidade superficial e adaptação marginal de Copings

Nogueira, Fabiane [UNESP] 19 April 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-04-19Bitstream added on 2014-06-13T20:38:34Z : No. of bitstreams: 1 nogueira_f_me_arafo.pdf: 1910245 bytes, checksum: 7a7c489d94c9295fab7ae06242bdc5e4 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A aplicação do titânio e ligas de titânio para implantes dentários e próteses têm crescido nos últimos anos devido às suas excelentes propriedades físicas e mecânicas. No entanto, o titânio tem alto ponto de fusão (1668ºC) e sob elevadas temperaturas, reage com elementos do ar atmosférico (oxigênio, nitrogênio, hidrogênio) e com componentes de diversos revestimentos. As reações entre o metal fundido e alguns elementos de revestimentos, principalmente fosfatados ou à base de sílica, resultam na formação de uma zona de contaminação superficial denominada “α-case”. Para minimizar este problema, revestimentos contendo óxidos menos reativos, tais como Al2O3, MgO, ZrO2 e CaO, têm sido desenvolvidos. Os revestimentos especiais para fundição de titânio à base de sílica, de MgO, alumina e espinélio apresentam um tempo de processamento bastante longo (8 a 10 horas). Recentemente, foi desenvolvido um revestimento à base espinélio com processamento acelerado (Trinell - Dentaurum, Ispringen, Germany) que permite a utilização de uma técnica de secagem em forno de microondas e temperatura de aquecimento inicial do forno de 400 ºC, diminuindo o tempo de processamento para cerca de 5 horas. No entanto, não existem estudos que comprovem a eficiência deste novo revestimento. O propósito deste estudo foi avaliar o efeito do novo material Trinell (TR) na camada de reação, porosidade interna, fluidez, rugosidade superficial e adaptação marginal de estruturas fundidas em titânio, quando comparado a dois revestimentos convencionais para fundição de titânio: um revestimento fosfatado, Rematitan Plus (RP) - controle negativo e outro à base de espinélio Rematitan Ultra (RU) - controle positivo. A camada de reação foi avaliada por meio de ensaio dureza Vickers; a medida da porosidade interna foi determinada por exame radiográfico; a rugosidade superficial... / The use of titanium and titanium alloys in dental implant and prosthesis has increased in the past few years because of their excellent physical and mechanical properties. However, titanium has a high melting point (1668 ºC) and inherent reactivity with elements of atmospheric air (oxygen, nitrogen, hydrogen) and with components of several investment materials under high temperatures. The reactions between molten metal and some of the elements of phosphate-bonded and other silica-based investment materials result in the development of a surface contamination zone called “α-case”. To minimize this problem, new investment materials containing less reactive oxides, such as Al2O3, MgO, ZrO2 and CaO have been developed. The commercial silica-, MgO-, Al2O3 - and spinel-based investments especially formulated to titanium casting demand a processing time in a range of 8 to 10 hours. Recently, a new short-cycle spinel-based investment (Trinell - Dentaurum, Ispringen, Germany) was developed. It has a reduced processing time - 5 hours in the furnace- because of an investment drying technique into microwaves oven followed by an initial heating in furnace at 400 °C. However, there are not studies which verify the efficiency of this new investment. The aim of this study was to evaluate the reaction layer, the internal porosity, the surface roughness, the castability and the marginal misfit of titanium castings performed with the new material, Trinell (TR), in comparison to two conventional investments for titanium castings: phosphate-bonded Rematitan Plus (RP) - negative control, and the spinel-based Rematitan Ultra (RU) - positive control. The reaction layer was evaluated by Vickers hardness; the measure of the internal porosity was determined by radiographic test; the surface roughness was measured with a surface-test analyzer, the castability was determined by the percentage of completely... (Complete abstract click electronic access below)
5

Comparação da adaptação cervical de estruturas metálicas para metalo-cerâmica obtidas através de técnica de fundição rápida e convencional, utilizando três revestimentos comerciais /

Yamaguti, Paulo Fukashi. January 2002 (has links)
Orientador: Eulália Maria Martins da Silva / Banca: Paulo Martins Ferreira / Banca: Humberto Gennari Filho / Resumo: Rotineiramente, o processo de fundição odontológica envolve um tempo de espera de até três horas, porém, os novos revestimentos permitem que este seja realizado em aproximadamente 40 minutos, inclusive com ganho de qualidade. Um destes revestimentos é aglutinado por fosfato melhorado e outro é cerâmico. Pelo fato de não encontrarmos dados comparativos a respeito destes novos materiais, realizamos um estudo, verificando a sua eficácia frente à técnica de fundição rápida e a técnica de fundição convencional, comparando qual proporciona melhores resultados de adaptação cervical das estruturas metálicas obtidas. Utilizamos três revestimentos: Termocast (Polidental), Heat Shock (Polidental) e o Micro Fine 1700 (Talladium Inc.), que foram submetidos às duas técnicas propostas e cada grupo experimental foi composto por 5 corpos de prova. A verificação do desajuste cervical foi realizada através de um microscópio comparador digital. Cada corpo de prova foi medido em 4 pontos pré-determinados (V, L, M e D). A análise dos resultados demonstrou que a técnica de fundição rápida apresentou desempenho desfavorável, quando comparados com a técnica convencional para um mesmo revestimento, e a melhor adaptação; tanto na técnica de fundição convencional, como na rápida, foi a do revestimento cerâmico. Concluímos que a técnica de fundição rápida é viável para o revestimento cerâmico, mas é preciso obter resultados favoráveis também aos outros revestimentos, antes de se abandonar a técnica de fundição convencional. / Abstract: Routinely, an up to three hours of waiting time is expected for dental casting process, however, new investments materials allow that this process may be performed in approximately forty minutes besides the improvement in the quality. One of the investments is agglutinated with improved phosphate and the other with ceramics. Due to the scarcity of comparative data regarding to these new materials, this study was performed to verify their behavior in accelerated and conventional casting techniques with the aim of finding out which material would provide better results of cervical fitting in the obtained metallic infra-structure. Three investments, Termocast (Polidental), Heat Shock (Polidental) and Micro Fine 1700 (Talladium, Inc.), were used, which were submitted to both casting techniques. Each experimental group was constituted by five specimens. The assessment of cervical fitting was performed by means of a comparator microscope. Each specimen was measured by using four pre-established points (V, L, M and D) as references. The results analysis showed that, for the same investment, accelerated casting technique presented worst fitting in comparison with the conventional technique, and best fitting, in both the conventional and accelerated techniques, was showed by ceramics investment. We conclude that the accelerated technique is viable for ceramic investment, but favorable results are needed with regard to other investments before the substitution of the conventional technique by the accelerated one. / Mestre
6

"Estudo comparativo de dois métodos utilizados na fundição de titânio cp" / Comparative study of two cp Ti casting methods.

Renata Cristina Silveira Rodrigues 29 April 2005 (has links)
Ao longo da última década, vários trabalhos têm destacado as vantagens do titânio e suas ligas e estudado a possibilidade de utilização para a confecção de estruturas metálicas de prótese parcial removível. Apesar das vantagens, o processo de fundição ainda apresenta problemas, limitando o uso do titânio. O objetivo deste estudo foi avaliar a influência de dois métodos de fundição, sobre microestrutura, microdureza, porosidade e força de retenção de grampos de PPR, fundidos em Co-Cr (controle) e titânio comercialmente puro (Ti cp). Foram utilizados os seguintes métodos: 1- arco voltaico (plasma) sob vácuo e pressão de argônio, com injeção do metal fundido por vácuo-pressão, e 2- indução sob vácuo e atmosfera de argônio, com injeção do metal fundido por centrifugação. Para análise da força de retenção foram confeccionadas estruturas metálicas com grampos circunferenciais sob retenção de 0,25; 0,50 e 0,75 mm, submetidas a ciclos de inserção/remoção simulando o uso por um período de 5 anos. Previamente ao ensaio de simulação, os corpos-de-prova foram radiografados em unidade laboratorial de raios X. Para o ensaio de microdureza Vickers e microestrutura foram confeccionados discos, com 5 mm de diâmetro e 2 mm de espessura, polidos metalograficamente. Os resultados mostraram que os métodos de fundição interferem nas características dos materiais estudados. As peças em titânio cp fundidas por plasma/vácuo-pressão apresentaram maior número de porosidades (50%) do que as fundidas por indução/centrifugação (16,66%). Para as peças fundidas em liga de Co-Cr, segundo a metodologia empregada, não foi possível observar a ocorrência de porosidades. As peças fundidas por plasma/vácuo-pressão apresentaram maior flexibilidade e as fundidas por indução/centrifugação apresentaram maior rigidez. Conseqüentemente, as forças de retenção foram, em geral, maiores para os corpos-de-prova obtidos por indução/centrifugação do que para aqueles obtidos por plasma/vácuo-pressão, com exceção da condição experimental de retenção 0,75 mm. Os corpos-de-prova fundidos por indução/centrifugação apresentaram, tanto para o Ti cp quanto para a liga de Co-Cr, maiores valores de microdureza Vickers do que os fundidos por plasma/vácuo-pressão. O Ti cp fundido pelo método de indução/centrifugação resultou em microestrutura de aspecto Widmanstätten, enquanto quando fundido pelo método de plasma/vácuo-pressão tem aspecto metalográfico tipo feather-like. Para a liga de Co-Cr, ambos os métodos resultaram em microestrutura dendrítica, mais fina para o método de plasma/vácuo-pressão. O Ti cp e a liga de Co-Cr, parecem ser afetados pela velocidade de resfriamento associada ao equipamento utilizado. Na análise química não foram detectadas alterações de composição dos materiais que indicassem contaminação resultante dos métodos de fundição utilizados. Assim, embora ainda apresentem problemas técnicos a serem resolvidos, ambos os métodos de fundição, indução/centrifugação e plasma/vácuo-pressão, permitem a obtenção de resultados satisfatórios na produção de estruturas metálicas de PPR em Ti cp. / Along the last decade, several jobs have been highlighting the advantages of titanium and titanium alloys and studied the possible utilization for removable partial dentures (RPD) metal frameworks confection. Although advantages, the cast process still presents problems, limiting the titanium use. The objective of this study was to evaluate the influence of two casting methods, on microstructure, microhardness, porosity and retention force of RPD clasps, casted in Co-Cr alloy (control) and commercially pure titanium (cp Ti). The cast methods used were: 1- voltaic arc (plasma) under vacuum and argon pressure, with molten metal injection by vacuum-pressure, and 2- induction under vacuum and argon atmosphere, with molten metal injection by centrifugation. For retention force analysis were made metal frameworks with circumferential clasps under retention of 0.25; 0.50 and 0.75 mm, submitted to insertion/removal cycles, simulating a 5 years use of a metal framework. Previously to the simulation test, the samples were radiographed in a laboratorial unit to verify the porosities occurrence. For Vickers microhardness test and microstructure analysis, disks with 5mm diameter and 2 mm thickness were made. The results showed that the casting methods interfere in the characteristics of studied materials. The cp Ti pieces casted by plasma/vacuum-pressure presents larger porosities number (50%) than that casted by induction/centrifugation (16.66%). For the pieces casted in Co-Cr alloy, according to the used methodology, wasn't possible to observe the occurrence of porosities. The pieces casted by plasma/vacuum-pressure presents larger flexibility and that casted by induction/centrifugation present larger rigidity. Consequently, the retention forces were, in general, larger for the samples obtained by induction/centrifugation than for those obtained by plasma/vacuum-pressure, except for the experimental condition with 0.75 mm retention. The samples casted by induction/centrifugation present, as for cp Ti as for Co-Cr alloy, larger Vickers microhardness values Vickers than that casted by plasma/vacuum-pressure. The cp Ti casted by induction/centrifugation method resulted in Widmanstätten microstructural aspect, while when casted by plasma/vacuum-pressure method has feather-like aspect. For Co-Cr alloy, both methods resulted in dendritic microstructure, finer for plasma/vacuum-pressure method. The cp Ti and Co-Cr alloy seem to be affected by the cooling rate associate to the used equipment. In the chemical analysis weren't detected materials composition alterations that indicate resultant contamination for the used casting methods. Thus, however still present technical problems to be solved, both casting methods, induction/centrifugation and plasma/vacuum-pressure, allow the obtainment of satisfactory results in the RPD metal frameworks production in cp Ti.
7

Análise da técnica de fundição rápida segundo a adaptação cervical de infra-estrutura de liga à base de Ni-Cr e expansões de presa e térmica de quatro revestimentos / Analysis of accelerated casting technique in accordance with marginal adaptation of Ni-Cr crown and curing expansion and thermal expansion of four investments

Yamaguti, Paulo Fukashi 10 September 2007 (has links)
Estudos recentes têm demonstrado que o aprimoramento dos revestimentos odontológicos para o uso da técnica de fundição rápida pode ser considerado uma realidade no seu uso diário no laboratório de prótese. Desta forma, obtêm-se peças metálicas fundidas em menor tempo, produz-se mais em pouco tempo e, diminuem-se os custos sem perda da qualidade. Mesmo assim, ainda há incógnitas sobre como estes revestimentos se expandem. Imagina-se que para obter a melhor adaptação cervical é necessária a maior expansão total do revestimento, mas alguns estudos têm demonstrado que outros fatores podem ser determinantes para obter a melhor adaptação cervical. O objetivo deste trabalho foi averiguar a adaptação cervical de infra-estruturas metálicas à base de Ni-Cr obtidas com quatro revestimentos odontológicos para a técnica de fundição rápida e analisar as expansões de presa e térmica dos mesmos. De cada revestimento foram obtidos 10 corpos de prova. Na análise da expansão de presa e térmica utilizou-se 3 corpos de prova de cada revestimento. Para a análise estatística, utilizou-se o ANOVA e o Teste de Tukey. Estas análises demonstraram que o uso do revestimento Heat Shock resultou na melhor adaptação cervical, seguido do Flash, Bellavest SH e Micro-Fine 1700. Na expansão de presa, no período de 15 minutos após a inclusão, nenhum dos revestimentos havia completado a sua total expansão. Na expansão térmica, dentro do forno no período de 20 minutos, todos os revestimentos apresentaram a expansão completada dentro de 15 minutos. Conclui-se que todos os revestimentos têm o potencial a oferecer peças fundidas com adaptação cervical adequada e que a obtenção da mesma não depende apenas da maior expansão total, mas também do comportamento da expansão de presa e da expansão térmica. Há também indícios de que a resistência à compressão do revestimento desempenha importância considerável. / With the improvement of dental investments for accelerated casting technique, recent studies have demonstrated that the procedure can be considered safe for daily use in the dental laboratory. Thus, cast pieces can be obtained in less time, the prosthetic work as a whole can be speed up and costs are cut with no quality compromise. Even though, there are still unanswered questions on how investments expand. It is thought that to reach the best cervical adaptation the greatest investment total expansion is needed, but some studies have demonstrated that other factors can be determining. The aim of this study was to verify the cervical adaptation of nickelchromium crowns cast using four dental investments for the accelerated casting technique and to analyze the curing and thermal expansion of such investments. For each investment, ten samples were obtained. For thermal expansion analysis three samples of each investment were used. For statistical purposes ANOVA and Tukey tests were used. The use of Heat Shock yielded the best results of cervical adaptation, followed by Flash, Bellavest SH and Micro-Fine 1700. For thermal expansion, 15 minutes after investment, none of the investments had reached their complete expansion. After 20 minutes inside the oven all investments had completed their expansion. It was concluded that all investments tested are suitable to offer cast pieces with adequate cervical adaptation. Adaptation depends not only of the greatest total expansion, but also of the curing and thermal expansion. There are indications that investment compression strength plays an important role on the technique.
8

O efeito da técnica de inclusão para fundição de titânio CP na fluidez, rusogidade, camada de reação e desajuste marginal /

Pieralini, Anelise Rodolfo Ferreira. January 2009 (has links)
Resumo: Esse estudo avaliou o efeito da tecnica de inclusao de revestimentos fosfatados nafluidez, rugosidade de superficie, camada de reacao (α-case) e adaptacao marginal de copings fundidos em Ti cp. Os padroes foram incluidos de forma convencional ou pela tecnica de inclusao experimental, na qual os padroes foram cobertos comRematitan Ultra - RU previamente a inclusao. Os revestimentos fosfatados estudados foram: Rematitan Plus (RP), Rema Exakt (RE), Castorit Super C (CA) e o revestimento a base de espinelio Rematitan Ultra (RU) foi o grupo controle. Sete grupos experimentais foram constituidos: G1: RU (controle); G2: RP; G3: RP e RU; G4: RE; G5: RE e RU; G6: CA; G7: CA e RU. Para fluidez foram feitos corpos-de-prova quadrados (15 mm X 15 mm X 0.3 mm) e a area (mm2) foi medida por um sistema analisador de imagens (n=8). Para a rugosidade de superficie as medidas (Ra) foram feitas em rugosimetro Mitutoyo (Mitutoyo SJ 400, Kanagawa, Japan) em corpos-de-prova quadrados (12 mm x 12 mm x 2 mm) n =8. A camada de reacao foi analisada por dureza Vickers, micro-analise por energia dispersiva (EDX), microscopia optica e a composicao dos revestimentos. Para dureza Vickers as medidas foram feitas em corpos-de-prova cilindricos (obtidos a partir dos sprues fundidos nos copos-de-prova para o teste de fluidez) em profundidades de 25, 50, 100, 150, 200 e 300Wm da superficie para o centro, em durometro Micromet 2100 (Buehler, Lake Bluff, Illinois, EUA) n= 8. Para a micro-analise por energia dispersiva (EDX) um equipamento EDX LINK ANALYTICAL, modelo QX 2000, com microscopio eletronico LEO (Zeiss - Germany) e detector OXFORD (Oxford Instrumentos de nano-analises Halifax Alta Rotacao WycombeBucks-HP12 3SE, UK) foram feitas em tres areas da camada de reacao (25 Wm, 75Wm e 150 Wm). Para a microscopia optica, as amostras foram polidas e limpas com solucao acida de Kroll por 20 segundos e observadas em Microscopio... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect investing technique with phosphate-bonded investment on the castability, surface of roughness, reaction layer (α-case) and marginal coping fit of CP titanium. For all analysis the specimen were coated with Rematitan Ultra - RU (experimental technique), previously to the inclusion (conventional technique) and invested into the phosphate-bonded investments: Rematitan Plus (RP), Rema Exakt (RE), Castorit Super C (CA). The seven groups studied were: G1: RU (control), G2: RP; G3: RP and RU; G4: RE; G5: RE and RU; G6: CA; G7: CA and RU. For castability, square patterns (15 mm X 15 mm X 0.3 mm) were made. The castability area (mm2) was measured by an image analysis system (n=8). The surface roughness was measured (Ra) with a rugosimeter Mitutoyo (Mitutoyo SJ 400, Kanagawa, Japan) in square resin patterns (12 mm x 12 mm x 2 mm) n =8. The reaction layer was analyzed by Vicker's hardness, Energy Dispersive X-ray microanalysis (EDX), optical microscopy and the investments composition were studied by X ray diffraction (XRD). The Vicker's hardness measurements were made sprue of castability test in cross - section at depths of 25, 50, 100, 150, 200 and 300Wm from the surface to the interior, using a durometer Micromet 2100 (Buehler, Lake Bluff, Illinois, EUA) n= 8. For Energy Dispersive X-ray microanalysis (EDX) was used an equipment EDX Link Analytical, model QX 2000, with Microscopy Electronic LEO (Zeiss - Germany) with detector Oxford (Oxford Instruments-Nano Analysis Halifax Road High WycombeBucks-HP12 3SE, UK) in three areas of reaction layer (25 Wm, 75Wm e 150 Wm). For the optical microscopy the samples were polished, cleaned and acid etched with the Kroll solution for 20 seconds and observed in an optical microscope Quimis (200 X) attached to an image analyzer Leika Qwin. For the study of the investments composition, samples with... (Complete abstract click electronic access below) / Orientador: Gelson Luís Adabo / Coorientador: Ricardo Faria Ribeiro / Banca: Sicknan Soares da Rocha / Banca: Renata Crisrina Silviera Ferracioli / Banca: João Neudenir Arioli Filho / Banca: Carlos Alberto dos Santos Cruz / Doutor
9

Análise da técnica de fundição rápida segundo a adaptação cervical de infra-estrutura de liga à base de Ni-Cr e expansões de presa e térmica de quatro revestimentos / Analysis of accelerated casting technique in accordance with marginal adaptation of Ni-Cr crown and curing expansion and thermal expansion of four investments

Paulo Fukashi Yamaguti 10 September 2007 (has links)
Estudos recentes têm demonstrado que o aprimoramento dos revestimentos odontológicos para o uso da técnica de fundição rápida pode ser considerado uma realidade no seu uso diário no laboratório de prótese. Desta forma, obtêm-se peças metálicas fundidas em menor tempo, produz-se mais em pouco tempo e, diminuem-se os custos sem perda da qualidade. Mesmo assim, ainda há incógnitas sobre como estes revestimentos se expandem. Imagina-se que para obter a melhor adaptação cervical é necessária a maior expansão total do revestimento, mas alguns estudos têm demonstrado que outros fatores podem ser determinantes para obter a melhor adaptação cervical. O objetivo deste trabalho foi averiguar a adaptação cervical de infra-estruturas metálicas à base de Ni-Cr obtidas com quatro revestimentos odontológicos para a técnica de fundição rápida e analisar as expansões de presa e térmica dos mesmos. De cada revestimento foram obtidos 10 corpos de prova. Na análise da expansão de presa e térmica utilizou-se 3 corpos de prova de cada revestimento. Para a análise estatística, utilizou-se o ANOVA e o Teste de Tukey. Estas análises demonstraram que o uso do revestimento Heat Shock resultou na melhor adaptação cervical, seguido do Flash, Bellavest SH e Micro-Fine 1700. Na expansão de presa, no período de 15 minutos após a inclusão, nenhum dos revestimentos havia completado a sua total expansão. Na expansão térmica, dentro do forno no período de 20 minutos, todos os revestimentos apresentaram a expansão completada dentro de 15 minutos. Conclui-se que todos os revestimentos têm o potencial a oferecer peças fundidas com adaptação cervical adequada e que a obtenção da mesma não depende apenas da maior expansão total, mas também do comportamento da expansão de presa e da expansão térmica. Há também indícios de que a resistência à compressão do revestimento desempenha importância considerável. / With the improvement of dental investments for accelerated casting technique, recent studies have demonstrated that the procedure can be considered safe for daily use in the dental laboratory. Thus, cast pieces can be obtained in less time, the prosthetic work as a whole can be speed up and costs are cut with no quality compromise. Even though, there are still unanswered questions on how investments expand. It is thought that to reach the best cervical adaptation the greatest investment total expansion is needed, but some studies have demonstrated that other factors can be determining. The aim of this study was to verify the cervical adaptation of nickelchromium crowns cast using four dental investments for the accelerated casting technique and to analyze the curing and thermal expansion of such investments. For each investment, ten samples were obtained. For thermal expansion analysis three samples of each investment were used. For statistical purposes ANOVA and Tukey tests were used. The use of Heat Shock yielded the best results of cervical adaptation, followed by Flash, Bellavest SH and Micro-Fine 1700. For thermal expansion, 15 minutes after investment, none of the investments had reached their complete expansion. After 20 minutes inside the oven all investments had completed their expansion. It was concluded that all investments tested are suitable to offer cast pieces with adequate cervical adaptation. Adaptation depends not only of the greatest total expansion, but also of the curing and thermal expansion. There are indications that investment compression strength plays an important role on the technique.
10

Propriedades mecânicas do titânio comercialmente puro e da liga Ti-6Al-4V fundidos em diferentes ambientes / Mechanical properties of commercially pure titanium and Ti-6Al-4V alloys casting in different environments

Bauer, José Roberto de Oliveira 05 October 2007 (has links)
Problema: O emprego do titânio e ligas de titânio para aplicações médicas e odontológicas tem aumentado nas últimas décadas, porém, o alto custo do material desestimula o seu uso rotineiro. Objetivos: Avaliar o efeito da pureza do argônio nas propriedades mecânicas, microestrutura e modo de fratura do titânio comercialmente puro (Grau I) e da liga Ti-6Al-4V. Material e Métodos: As fundições para cada liga foram realizadas em uma máquina de indução eletromagnética com um argônio de alta pureza (99,999%) e um argônio conhecido como industrial (99,98%). Os testes de resistência à tração, limite de proporcionalidade e alongamento foram realizados em máquina de ensaio universal sob velocidade de 1 mm/min. Os espécimes fraturados foram embutidos em resina fenólica (baquelite) e polidas para a realização da microdureza Vickers (100g/15s), a a 25, 50, 100, 200 e 500?m da borda do corpo-de-prova. A microestrutura das ligas também foi analisada em alguns espécimes, com o objetivo de avaliar a superfície fraturada dos espécimes alguns foram submetidos à microscopia eletrônica de varredura. Análise estatística: Os dados provenientes de cada teste mecânico foram submetidos a uma análise de variância (tipo de titânio vs. pureza do argônio) e teste de Tukey (? = 0,05). Os dados de microdureza Vickers foram submetidos a uma análise de variância de medidas repetidas (fatores principais: liga e argônio) e medida repetida: distância e teste de Tukey para o contraste entre médias (? = 0,05). Resultados: O grau de pureza do gás não influenciou os valores do limite de proporcionalidade, da resistência à tração e alongamento, assim como a microdureza Vickers, microestrutura e padrão de fratura. A liga Ti-6Al-4V apresentou alto valores de resistência à tração, limite de proporcionalidade e microdureza Vickers, e baixo alongamento. A microdureza dos materiais foi alta nas proximidades da borda, mas a pureza do argônio não teve influência alguma. Conclusões: O argônio industrial pode ser utilizado para realizar as fundições do Ti CP e Ti-6Al-4V sem prejuízos nas suas propriedades. / Background: Although CP titanium and titanium alloys have been used for medical and dental applications, their high cost has not stimulated their current use. Objective: The purpose of this study was to evaluate the effect of argon purity on the mechanical properties, microstructure and fractography of CP Ti (Grade I) and Ti-6Al- 4V cast alloys. Material and Methods: The castings for each alloy were made in a centrifugal casting machine using either a high-purity (99.999%) and or an industrial argon gas (99.98%). The ultimate tensile strength (UTS), proportional limit (PL) and elongation (EL) were evaluated in a universal testing machine at a crosshead speed of 1 mm/min. The fractured specimens were embedded in phenolic resin and polished down for Vicker\'s microhardness (VHN) measurement (100g, 15s) from 25 ?m below the cast surface, then at 50?m, 100?m, 200?m and 500?m. The microstructures of the alloys were also revealed. Scanning electron microscopy fractography was undertaken for the fractured surfaces after tensile testing. The data from the mechanical tests and hardness were subjected to a two-way ANOVA and Tukey\'s test (? = 0.05). Results: The mean values of UTS, PL, EL and VHN were not affected by the argon gas purity. Higher UTS, PL and VHN and lower EL was observed for Ti-6Al-4V. The microhardness values of both alloys were higher at the surface layers and it was not influenced by the argon gas purity. Conclusions: It was concluded that the industrial argon gas can be safely used to cast CP Ti and Ti-6Al- 4V, since it does not alter the mechanical properties of the studied alloys.

Page generated in 0.1153 seconds