81 |
Avaliação da resistência de união de reparos em resinas compostas convencionais e bulkfill / Repair bond strength evaluation in conventional composite resins and bulkfillTrevisan, Tamara Carolina [UNESP] 08 April 2016 (has links)
Submitted by Tamara Carolina Trevisan null (tatatct@hotmail.com) on 2016-05-11T16:56:37Z
No. of bitstreams: 1
DISSERTAÇÃO Tamara final.pdf: 952564 bytes, checksum: ebb18de0dbf1a31f23929f75262d327d (MD5) / Rejected by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo:
O arquivo submetido está sem a ficha catalográfica. Lembramos que a versão submetida por você é considerada a versão final da dissertação/tese, portanto não poderá ocorrer qualquer alteração em seu conteúdo após a aprovação.
Corrija esta informação e realize uma nova submissão contendo o arquivo correto.
Agradecemos a compreensão.
on 2016-05-13T16:10:54Z (GMT) / Submitted by Tamara Carolina Trevisan null (tatatct@hotmail.com) on 2016-05-16T22:27:11Z
No. of bitstreams: 1
DISSERTAÇÃO Tamara Final Biblioteca.pdf: 1025909 bytes, checksum: 4723250559375bfac2090cfb75b0314b (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-05-17T18:48:39Z (GMT) No. of bitstreams: 1
trevisan_tc_me_arafo.pdf: 1025909 bytes, checksum: 4723250559375bfac2090cfb75b0314b (MD5) / Made available in DSpace on 2016-05-17T18:48:39Z (GMT). No. of bitstreams: 1
trevisan_tc_me_arafo.pdf: 1025909 bytes, checksum: 4723250559375bfac2090cfb75b0314b (MD5)
Previous issue date: 2016-04-08 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Técnicas de reparos de restaurações vêm sendo amplamente utilizadas como um tratamento alternativo e conservador á substituição de restaurações defeituosas. O conhecimento do material a ser reparado e de um protocolo ideal, permitiria uma melhor relação biomecânica entre dente e material restaurador e possibilitaria técnicas eficazes e menos invasivas. O objetivo do presente estudo foi avaliar a resistência de união de reparo de diferentes resinas compostas, sob a influência de tratamentos de superfície, especialmente em relação a uma nova proposta comercial denominada de resinas "bulk fill". Para isso, foram confeccionados corpos de prova com diâmetro de 8mm por 4mm de altura, de diferentes classes de resinas compostas: Z350XT, Z250XT, Grandio, Epricord, Tetric Bulkfill, Xtra Fill e Sonic Fill (n=15). Estes passaram por processo de envelhecimento artificial, realizado por meio de armazenamento em estufa com saliva artificial por 3 meses, sendo realizada a troca da saliva semanalmente, e finalizado com termociclagem 5o e 55ºC por 20 segundos em água para 1000 ciclos. Foram distribuídos aleatoriamente em três subgrupos, de acordo com o tratamento de superfície (n=5): G1- Controle- sem tratamento prévio; G2- Jateamento óxido alumínio; G3- Jateamento óxido de sílica. Após a aplicação dos respectivos tratamentos de superfície, cada espécime foi reparado com resina composta Z100 em incrementos de aproximadamente 2mm e fotopolimerizado em um aparelho de fotopolimerização convencional (Bluephase, Ivoclar Vivadent, Liechtenstein) até obtenção 4 mm de altura. A seguir os espécimes foram submetidos a novo ciclo de envelhecimento artificial por uma semana em estufa com saliva artificial, e termociclagem 5o e 55ºC por 20 segundos em água para 1000 ciclos. As amostras foram seccionadas em seu longo eixo em máquina de corte (Isomet 1000, Buehler Ltd, Lake Bluff, IL, EUA), a fim de se obter espécimes no formato de paralelepípedo, com a linha de união localizada centralmente. Cada espécime foi individualmente fixado em máquina de microtração Micro Tensile Tester- MTT (BISCO, Inc. 1100 W. Irving Park Rd. Schaumburg, IL 60193 USA 1- 800-247-3368), e submetido a teste de microtração com velocidade de 0,5 mm/min e célula de carga de 500N. Realizou-se análise de variância para avaliar a influência dos diferentes materiais e tratamentos de superfície na resistência de união de reparos. O padrão de fratura observado nos reparos foi analisado por meio do teste de qui-quadrado( 2 ), para uma com significância estatística de 5%. A análise de variância mostrou que existe diferença estatisticamente significativa (p=0,001) entre a resistência coesiva dos materiais, e para interação material e tratamento de superfície sobre a resistência de união dos reparos (p=0,001). O teste de quiquadrado( 2 ) também mostrou que existe associação entre o tipo de fratura e as variáveis materiais e tratamentos de superfície (p=0.001). Concluindo que, as diferentes classes de resinas compostas testadas respondem de maneira diferente frente aos tratamentos de superfície aplicados, não sendo possível estabelecer um protocolo clínico ideal para procedimentos de reparo. Além disso, as resinas bulkfill testadas possuem resistência de união aceitável, semelhante às demais classes de resinas compostas, demonstrando que procedimentos de reparo são indicados para esses materiais. / Restoration repair techniques have been widely used as an alternative and conservative treatment for replacement of defective restorations. The knowledge of the material to be repaired and an ideal protocol would allow a better biomechanical relationship between tooth and restorative material and would allow techniques effective and less invasive. The aim of this study was to evaluate the repair's bond strength of different composite resins under the influence of surface treatments, especially in relation to a new commercial proposal called Bulk-fill Resin-based Composites. For this, specimens were prepared with 8 mm diameter by 4 mm in height, of different classes of composite resins: Z350XT, Z250XT, Grandio, Epricord, Tetric Bulkfill, Xtra Fill e Sonic Fill (n=15). These were submitted to artificial aging process by storing in an oven with artificial saliva for 3 months, and their exchange performed weekly and finished 5 o and 55°C thermocycling for 1000 cycles. They were randomly divided into three subgroups, according to the surface treatment (n=5): Control group- without treatment (G1), Aluminum oxide blasting (G2), Silica oxide blasting (G3). After applying the respective surface treatments, each specimen was repaired with composite resin (Z-100, 3M ESPE) in increments of 2mm, approximately, and light cured in a conventional light-curing unit (Bluephase, Ivoclar Vivadent, Liechtenstein) to obtain 4 mm height. Then specimens were subjected to a new cycle of artificial aging for one week incubated in artificial saliva and thermal cycling 5 and 55°C for 1000 cycles. The samples were sectioned in their long axis in a cutting machine (Isomet 1000, Buehler Ltd, Lake Bluff, IL, USA) in order to obtain the specimens in parallelepiped shape with union line centrally located. Each specimen was individually set at a micro-tensile machine Micro Tensile Tester - MTT (BISCO, Inc. 1100 W. Irving Park Rd. Schaumburg, IL 60193 USA 1-800-247-3368), and submitted to micro-tensile test at 0.5 mm/min speed with a 500 N load cell. It was performed variance analysis for there is influence of different materials and surface treatments on the bond strength of repair. The fracture pattern observed in repairs was analyzed using the chi-square test ( 2 ) with 5% statistical significance level. Analysis of Variance showed that there was a statistically significant difference (p=0.001) between the tensile strength of materials, and for interaction materials and surface treatment on bond strength of repair (p=0.001). There was association between the type of fracture and the variables material and surface treatments (p=0.001). It can be concluded that the different classes of composites tested respond differently compared to the applied surface treatment and it is not possible to establish a clinical protocol for repair procedures. Moreover, the tested bulk fill resins have acceptable bond strength, similar to other classes of composites, demonstrating that these materials are suitable for repair procedures.
|
82 |
Resistência à fratura de diferentes núcleos de preenchimento com compósitos bulk fill em dentes com extensa destruição coronária /Oliveira, Carlos Rangel de Moura January 2019 (has links)
Orientador: José Maurício dos Santos Nunes Reis / Resumo: Este estudo objetivou avaliar a resistência máxima e o padrão de fratura de diferentestécnicas para núcleo preenchimento associados a pinos de fibra de vidro em incisivoslaterais inferiores bovinos com extensa destruição coronária. Quarenta dentes forampreparados endodonticamente, divididos aleatoriamente em 4 grupos experimentais(n=10) e um pino de fibra de vidro (Whitepost DC0,5) foi cimentado com LuxaCore Zpara todos os grupos. A confecção dos núcleos de preenchimento foi realizada, apósobtenção de férula cervical de 1,0 mm, com: FOBF-Filtek One Bulk Fill; FZ350- FiltekZ350 XT; FBFF-Filtek Bulk Fill Flow; e LCZ-LuxaCore Z. Coroas totais de zircônia (YTZP) produzidas em CAD/CAM foram cimentadas com RelyX U200. Apósarmazenamento em água destilada a 37°C por 48 h, os corpos-de-prova foramsubmetidos a ciclos térmicos (10.000 ciclos, 5-55ºC, banhos de 30s) e, posteriormente,ao ensaio mecânico de resistência à fratura por força compressiva aplicada (1,0mm/min) em 135º ao longo eixo do dente em máquina eletromecânica (EMIC DL2000).A força máxima suportada por cada espécime foi registrada em Newton. O modo defratura foi classificado por meio de análise em lupa estereomicroscópica (30X). Osdados de resistência à fratura foram analisados pelo teste não paramétrico de KruskalWallis, seguido pelo post-hoc teste de Dunn. Os dados dos padrões de fratura foramanalisados pelo teste exato de Fisher (α=0,05). Não foram observadas diferençassignificativas (p>0... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study aimed to evaluate the ultimate fracture strength and failure modes of different core techniques associated with intraradicular fiberpost in bovine mandibular lateral incisors with extensive coronary destruction. Forty teeth were prepared endodontically, randomly divided into 4 experimental groups (n=10) and a fiberpost (Whitepost DC0.5) was cemented with LuxaCore Z for all groups. The core was confeccioned, after obtaining a 1.0 mm cervical ferrule, with: FOBF-Filtek One Bulk Fill; FZ350- Filtek Z350 XT; FBFF-Filtek Bulk Fill Flow; and LCZ-LuxaCore Z. Total zirconia crowns (Y-TZP) produced by CAD/CAM were cemented with RelyX U200. After storage in distilled water at 37ºC for 48 h, the specimens were submitted to thermal cycling (10,000 cycles, 5- 55ºC, 30 s dwell time) and, afterwards, to the mechanical test of compressive strength fracture (1.0 mm / min) at 135º along the tooth axis in electromechanical machine (EMIC DL2000). The ultimate load supported by each specimen was recorded in Newton. The fracture mode was classified by means of stereomicroscopic loupe analysis (30X). The fracture strength data were analyzed by the non-parametric Kruskal-Wallis test, followed by the post-hoc Dunn test. The data of the fracture modes were analyzed by Fisher's exact test (α=0.05). No significant differences (p>0.05) were observed among the FOBF, FZ350 and FBFF groups (mean ranks= 20.30, 12.20 and 23.20, respectively). LCZ (mean rank= 26.30) produced similar results to those... (Complete abstract click electronic access below) / Mestre
|
83 |
Brilho, rugosidade e integridade da superfície de resinas compostas = efeito do polimento e escovação / Bright, roughness and integrity of the surface of composite resin : effect of polishing and brushingCarrilho Neto, Antonio, 1962- 18 August 2018 (has links)
Orientadores: Lourenço Correr Sobrinho, Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T20:46:54Z (GMT). No. of bitstreams: 1
CarrilhoNeto_Antonio_D.pdf: 8464064 bytes, checksum: 16996840d4c6ac4cececfc832c5f7e73 (MD5)
Previous issue date: 2011 / Resumo: O objetivo neste estudo foi avaliar a influência de sistemas de polimento e escovação mecânica simulada, sobre o brilho, rugosidade e integridade da superfície de materiais restauradores estéticos. Quatro compósitos foram avaliados: Filtek Z350 XT - 3M ESPE, Charisma Opal - Heraeus Kulzer, Amelogen Plus - Ultradent, Tetric N-Ceram - Ivocler Vivadent. Vinte amostras cilíndricas padronizadas foram obtidas para cada material e separadas aleatoriamente em 2 grupos (n=10), sendo que cada grupo foi submetido a um dos dois procedimentos de polimento (Sof-Lex - 3M ESPE e PoGo - Dentsply Caulk). Em seguida, todas as amostras foram submetidas às avaliações de brilho, mensurado com medidor (Zehntner ZGM 1120 Glossmeter) e a rugosidade com rugosímetro (Surfcorder SE1700 - Kosaka Lab) e submetidas a 30000 ciclos mecânicos de escovação simulada, utilizando solução de dentifrício (Colgate) e água destilada. Na seqüência da escovação, as mensurações de brilho e rugosidade foram repetidas. Em seguida, as amostras foram submetidas aos procedimentos de polimento, seguidos das avaliações de brilho e rugosidade. Os dados foram submetidos à ANOVA para medidas repetidas e teste de Tukey (p?0,05). Adicionalmente, amostras iniciais, escovadas e polidas foram examinadas em microscopia eletrônica de varredura (5600LV - Jeol) para avaliação qualitativa da integridade da superfície. Com base nos resultados de Rugosidade Média encontrados após a escovação simulada, pode-se concluir que a resina nanoparticulada apresentou menor rugosidade pela escovação mecânica (0,275 ?m) e maior brilho por ambos os métodos de polimento (PoGo 71,78 GU e Sof-Lex 70,64 GU); A escovação mecânica aumentou os valores médios de rugosidade e diminuiu o brilho dos compósitos; Os sistemas de polimento não foram capazes de recuperar a lisura quando comparados à fase inicial; Ambos os sistemas de polimento melhoraram o brilho deixado pela escovação, com exceção do compósito Amelogem Plus. Com base nas análises das imagens do MEV, foi possível observar que o sistema de polimento de múltiplos passos (Sof-Lex - 3M ESPE) favorece a presença de sulcos profundos / Abstract: The purpose in this study was to evaluate the influence of polishing systems and simulated mechanical toothbrushing, about gloss, rugosity and integrity on surfaces of esthetic restorative materials. Four composites were evaluated: Filtek Z350 Supreme (tem que colocar "supreme" no ingles?) XT (3M ESPE), Charisma Opal (Heraeus Kulzer), Amelogen Plus (Ultradent) and Tetric NCeram (Ivoclair Vivadent). Twenty cylindrical standardized specimens, for each material, were fabricated and ramdomly divided in two groups (n=10), each group being submitted to one of the two polishing protocols (Sof-Lex - 3M ESPE; POGO Dentsply Caulk). After, all specimens were submitted to the following evaluations, surface optical gloss was determined using a glossmeter (ZGM 1120 Glossmeter - Zehntner) and surface roughness was measured with a surface profilometer ( Surfcorder SE 1700 -Kosaka Lab.), and specimens were submitted to 30,000 mechanical simulated brushing cycles, with a dentifrice-water slurry (Colgate) and distilled water. Following brushing, gloss and roughness measurements were evaluated again. Then, specimens were submitted to the polishing process, followed by gloss and roughness evaluations. Data were submitted to ANOVA statistical analysis for repeated measures and Tukey Test (p?0,05). Additionally, initial specimens, brushed and polished, were evaluated under scanning electron microscopy (5600 LV-Jeol) for qualitative surface integrity. Based on the middle rugosity results found after simulated brushing, could be concluded that nanometric composites showed lower rugosity when submitted to mechanical simulated toothbrushing (0,275 ?m) and higher gloss with both polishing protocols (PoGo 71,78 GU e Sof-Lex 70,64 GU); mechanical tooth brushing increased the rugosity middle values and decreased the composite gloss; The polishing systems were not capable to recover smoothness when compared to the initial phase (polyester matrix); both polishing system improved gloss given by brushing, exceptionally for the Amelogen Plus composite. Based on MEV image analysis, was observed that the multiple step polishing system (Sof-Lex - 3M ESPE) favors the presence o deep sulcus / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
|
84 |
Influência da estabilidade de cor, rugosidade superficial e resistência de união em diferentes materiais restauradores CAD/CAM /Lorenzetti, Camila Cruz. January 2019 (has links)
Orientador: José Roberto Cury Saad / Resumo: Com o avanço dos materiais cerâmicos e dos sistemas adesivos, aliados a alta exigência estética dos pacientes, restaurações cerâmicas têm sido cada vez mais utilizadas clinicamente. Restaurações cerâmicas realizadas pelo CAD/CAM aliam alta tecnologia com praticidade, especialmente os blocos que não requerem fase de cristalização em forno, obtendo resultados satisfatórios em curto tempo. Este estudo teve como objetivo avaliar a estabilidade de cor, rugosidade superficial e resistência de união de diferentes materiais restauradores do sistema CAD/CAM e uma resina composta. Foram utilizados os blocos cerâmicos na cor A2: Celtra Duo- ZL (Dentsply/Sirona), Enamic - HC (Vita), Lava Ultimate - NC (3M) e Resina Composta Filtek Z350XT- CR (3M). Para os estudos 1 e 2, foram realizados 2 tipos de procedimentos de polimento: borrachas Ceramisté - Standard, Ultra e Ultra II (Shofu); borrachas Ceramisté + pasta porcelize (Cosmedent) + discos de feltro Flexibuff (Cosmedent) e posteriormente realizadas imersões em saliva artificial(S1), café(2) e coca-cola(3). Espécimes para cada grupo (n=10), foram imersos em cada solução armazenada em estufa a 37ºC por 60 dias. As leituras de cor (E) foram realizadas nos tempos inicial, 30 dias, 60 dias e repolimento. As leituras de rugosidade superficial (Ra) foram realizadas inicialmente antes das imersões, após 30 dias e após 60 dias de imersão. Estudo 3 avaliou diferentes técnicas de adesão (acido fluorídrico+silano+adesivo; acido fluorídrico+adesivo u... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Considering the advancement of ceramic materials and adhesive systems, allied to the high esthetic requirement of patients, ceramic restorations have been increasingly used clinically. Ceramic restorations performed by CAD / CAM combine high technology with practicality, especially the blocks that do not require crystallization phase in the oven, obtaining satisfactory results in a short time. This study aimed to evaluate the color stability, surface roughness and bond strength of different CAD / CAM system restorative materials and a composite resin. The ceramic blocks in the A2 color were: Celtra Duo- ZL (Dentsply / Sirona), Enamic-HC (Vita), Lava Ultimate-NC (3M) and Filtek Z350XTCR (3M) Composite Resin. For studies 1 and 2, two types of polishing procedures were performed: Ceramisté - Standard, Ultra and Ultra II rubbers (Shofu); Ceramisté rubbers + paste porcelain (Cosmedent) + Flexibuff felt discs (Cosmedent) and subsequently immersed in artificial saliva (S1), coffee (2) and coke (3). Specimens for each group (n = 10) were immersed in each solution stored in an oven at 37ºC for 60 days. Color readings (E) were performed at the initial, 30 days, 60 days and repolder times. Surface roughness readings (Ra) were performed before immersion, after 30 days and after 60 days of immersion. Study 3 evaluated different adhesion techniques (hydrofluoric acid + silane + adhesive, hydrofluoric acid + universal adhesive, silica sandblasting + silane + adhesive, silica sandblasting + ... (Complete abstract click electronic access below) / Doutor
|
85 |
Avaliação da resistência à fratura de próteses fixas provisórias implanto-suportadas variando o comprimento do cantilever e o tipo de fibra: fibras de vidro e fibras de poli(aramida) / Evaluation of the resistance to the fracture of temporary fixed prostheses implant-supported varying the extension of the cantilever and the fiber type: glass fibers and poliaramid fibersColán Guzmán, Paola del Rosario 01 March 2007 (has links)
No tratamento reabilitador oral as restaurações provisórias são de suma importância. A resistência e a longevidade dos materiais utilizados em sua execução são críticas, principalmente em tratamentos prolongados e em espaços desdentados extensos. O objetivo deste trabalho foi avaliar a resistência e o modo de fratura de espécimes que simularam uma prótese fixa de três elementos variando o comprimento do cantilever (7, 14 e 21mm), confeccionadas em resina acrílica poli(metilmetacrilato) (PMMA) autopolimerizável, com e sem reforço em seu interior, construídos sobre componentes para implantes. Os reforços utilizados foram: fibras de vidro (Fibrante® - Ângelus®, Londrina, PR, Brasil) e fibras de poli(aramida) (Kevlar® - Du Pont®, USA). Os grupos foram constituídos de 10 espécimes cada, incluindo um grupo controle, sem reforço. Os espécimes foram submetidos à carga compressiva até a fratura. A análise dos resultados (ANOVA, p < 0,05), para o teste de resistência, mostrou não haver diferença estatística entre os grupos com respeito ao tipo de reforço, sendo que houve diferença estatística significante no que respeita ao comprimento do cantilever. Quando o comprimento do cantilever foi de 7mm todos os grupos apresentaram os valores médios de resistência a fratura, em N, significativamente maiores que os apresentados pelos grupos com 14 e 21mm de comprimento. Em relação ao modo de fratura os grupos reforçados apresentaram fraturas mais favoráveis ao reparo, tendo sido do tipo Parcial. / In the oral rehabilitator treatment, the provisory restorations have extremely importance. The resistance and durability of materials used in the execution are critical, especially in extended treatments and in vast toothless spaces. The goal of this work was to demonstrate the resistance and the types of fracture of specimens that simulate a fixed prosthesis of three elements changing the extension of cantilever (7, 14 e 21mm), made of acrylic resin polymethylmethacrylate (PMMA) autopolymer, with and without reinforcement in its interior, built over implant components. The reinforcements used were: fiberglass (Fibrante® - Angelus®, Londrina, PR, Brazil) and poliaramid fiber (Kevlar® - Du Pont®, USA). The groups have 10 specimens each, including a group of control, without reinforcement. The specimens were submitted to a compressor charge until its fracture. The analysis of results (ANOVA, p < 0,05) for the test of resistance, showed that there is no statistic difference between the groups regarding the type of reinforcement; however, there is a significant statistic difference regarding the cantilever extension. When the extension of cantilever was 7mm, all groups showed medium values of resistance to fractures, in N, significant more than the showed by the groups with 14 and 21mm of extension. In relation with the types of fracture, the reinforcement groups show fractures more favorable to be repaired, even when they were partially fractured.
|
86 |
Influência do ultra-som na resistência à abrasão e na rugosidade de superfície dos cimentos de ionômero de vidro submetidos à escovação / Influence of the ultrasound in the abrasion resistance and in superficial roughness of the glass ionomer cements submitted to toothbrushLouro, Renata Loureiro 30 March 2007 (has links)
O objetivo deste estudo foi avaliar o desgaste à abrasão decorrente da escovação simulada de cimentos de ionômero de vidro sonificados, por análise da alteração de massa e da textura superficial. Os materiais avaliados foram: Fuji II LC (GC América), Resiglass (Biodinâmica), Vitro Fil LC (DFL), Fuji IX (GC América), Ketac Molar (3M ESPE), Vitro Molar (DFL), Bioglass (Biodinâmica), Vitro Fil (DFL), que foram manipulados conforme instruções do fabricante, constituindo-se no grupo controle, e um grupo submetido ao ultra-som EMS FT-081 DN Mini PIEZON (EMS, Nyon, Geneva, Switzerland), constituindo-se no grupo experimental. Os corpos-deprova foram confeccionados em uma matriz de dente bovino, com um orifício central com dimensões de 5mm de diâmetro e 3mm de espessura. Foram confeccionados 10 corpos-de-prova para cada material e cada grupo (experimental e controle). O teste de simulação da escovação foi realizado numa máquina automática para simulação de escovação (M.N. São Carlos - Brasil). A alteração de massa foi verificada pela diferença entre a massa inicial (antes da escovação) e final (após a escovação), em balança de precisão (cap. 210g, sens. 0,0001g mod. Mark 210A LICiT-Bel/Proc. Italian), com precisão de quatro casas decimais. A análise da rugosidade superficial em Ra foi determinada pela diferença entre as médias de cinco leituras, iniciais e finais, com um rugosímetro Hommel Tester T1000 (Hommelwerke, GmbH, Alte Tuttinger Strebe 20. D-7730 VS-Schwenningen). Os resultados obtidos foram submetidos à análise de ANOVA a dois critérios e Tukey (p<0,05). Quanto à perda de massa não houve diferença estatisticamente significante em relação à aplicação do ultra-som (p=0,403). No entanto, houve diferença estatisticamente significante para os diferentes Ionômeros estudados, onde p<0,001, mais precisamente do Resiglass e do Vitro Molar com os demais materiais. No que se refere à alteração de rugosidade houve diferença estatisticamente significante para a condição utilização ou não do ultra-som (p=0,043), mas não para os diferentes materiais estudados, onde p=0,264. A excitação ultra-sônica durante a presa inicial piora a rugosidade de superfície e não apresenta nenhuma influência na perda de peso. / The purpose of this work was to evaluate abrasion resistance, by means of weight loss, and surface roughness (SR) of GIC, using ultrasonic excitation as a command set. The materials tested were Fuji II LC and Fuji IX (GC Corporation), Ketac Molar (3M ESPE), Resiglass and Bioglass (Biodinâmica), Vitro Fil LC, Vitro Molar and Vitro Fil (DFL). Twenty specimens of each GIC brand were evaluated, being half submitted to ultrasound (US) (Piezon - EMS, Switzerland). The materials were placed in bovine tooth matrix (5mm inner diameter and 3mm of thickness). Initial weight was carried out by means of a digital balance (210A LICiT/Italian). The initial SR was quantitatively assessed by measuring the surface roughness using Hommel Tester T1000 (Hommelwerke, Germany) determined by the average of 5 random measurements in each sample. The specimens were submitted to brushing abrasion test. Weight loss and surface roughness, for each specimen were calculated based on the difference between the initial and final weight and surface roughness means, respectively. Weight loss (g) varied between 0,0001 and 0,0090 with US and 0,0001 and 0,0123 without US. Surface roughness (µm) varied between 0,0770 and 0,4330 with US and -0,0270 and 0,3520 without US. The results, analyzed by two way ANOVA and Tukey\'s test (p<0,05), presented statistically significant difference in the surface roughness when the GIC was submitted or not to US (p=0,043) while no statistical difference was observed among the GIC brands (p=0,264). The weight loss presented statistically significant difference between the tested GIC brands (p<0,010), while no influence on the weight loss by the use of US was observed (p=0,403). Ultrasonic excitation during initial cure does not improve surface roughness of GIC, and does not present any influence on weight loss.
|
87 |
Avaliação da relação entre o desajuste vertical em interfaces pilar/cilindro protético fundido e sobrefundido e a perda de torque de parafusos protéticos de titânio / Evaluation of the relationship between vertical misfit in abutment / casting and pre-machined prosthetic cylinder joint and loosening of prosthetic titanium screwsFalcão Filho, Hilmo Barreto Leite 15 December 2005 (has links)
Este estudo foi desenvolvido com o objetivo de avaliar os níveis de desajustes em interfaces pilar / cilindros protéticos obtidos a partir de cilindros calcináveis e pré-usinados fundidos em duas diferentes ligas metálicas, e a perda de torque em parafusos protéticos de titânio utilizados para fixar estas interfaces, analisando a relação entre estas variáveis. Os parafusos protéticos foram submetidos a análises de microscopia eletrônica de varredura antes e após o aperto. Os valores de torque foram aferidos por um torquímetro digital, os valores de desajustes registrados por um microscópio óptico e foram registradas imagens dos corpos-de-prova por uma câmera digital acoplada a outro microscópio óptico. Todos os valores de desajustes e perda de torque foram submetidos a testes de freqüência e analisados pelos testes T e Mann-Whitney para comparação entre os grupos, e pelo teste Spearman para a verificação da correlação entre as variáveis. Os resultados evidenciaram diferenças estatisticamente significantes (p ≤ 0,05) para os diferentes tipos de cilindros utilizados quanto ao desajuste (p = 0,000), e não foram evidenciadas diferenças estatísticas significantes (p ≤ 0,05) entre os cilindros quanto à perda de torque (p = 0,052) nem entre as diferentes ligas quanto ao desajuste (p = 0,615) e perda de torque (p = 0,811). A análise estatística confirmou a correlação (p ≤ 0,05) entre as variáveis desajuste e perda do torque (p = 0,017). Foram verificadas alterações nas superfícies das roscas dos parafusos após o torque e defeitos de fundição em alguns cilindros protéticos, especialmente nos cilindros fundidos a partir de cilindros calcináveis. De acordo com os resultados, a metodologia empregada e as limitações deste estudo, concluiu-se que os cilindros pré-usinados proporcionam níveis de desajustes mais favoráveis do que os cilindros calcináveis, existe correlação entre os desajustes nas interfaces pilar / cilindro protético e perda de torque nos parafusos de titânio, e defeitos de fundição podem influenciar nos desajustes. / This study was developed with the objective to evaluate the levels of misfit in abutment / coping joint obtained from casting and pre-machined copings in two different alloys and the torque loosening in prosthetic titanium screws used to connect this joint, analyzing the relation between the two variable. The prosthetic screws were submitted to analyses on scanning electron microscopy before and after the torque. The values of torque were checked by one digital torque meter, the values of misfits were registered by an optic microscope and images of the samples were registered by an digital camera connected to another optic microscope. All the values of misfits and torque loosening was submitted to frequency tests and analyzed by the T and Mann-Whitney tests for the comparison between the groups, and by the Spearman test for the verification of the correlation between the two variable. The results had evidenced significant statistical differences (p ≤ 0,05) for the different types of copings used about misfit (p = 0,000), and had not been evidenced significant statistical differences (p ≤ 0,05) between the copings about the torque loosening (p = 0,052), neither for the different alloys about misfit (p = 0,615) and torque loosening (p = 0,811). The statistical Spearman test analysis confirmed the correlation between the misfit and torque loosening (p = 0,017). It was verified alterations in the surfaces of the threads of the screws after the torque and casting defects in some prosthetic cylinders, especially in the casting cylinders. In accordance with the results, the employed methodology and the limitations of this study, it has been concluded that the pre-machined copings provide more favorable levels of misfits than the casting copings, there is correlation between misfits in the abutment / coping joints and torque loosening in the titanium screws, and casting defects should influence in the misfits.
|
88 |
Incidência de fraturas em próteses fixas: estudo retrospectivo. Análise da sobrevivência de próteses metalocerâmicas após um período mínimo de quatro anos em função / Fractures Incidence on fixed prostheses: a retrospective studyAzevedo, Fabiola Pontes 09 August 2017 (has links)
As próteses metalocerâmicas ainda são apontadas como o tratamento de escolha em reabilitação oral por apresentarem altas taxas de sobrevivência, mesmo que o fator estético possa ser comprometido devido às propriedades óticas relacionadas à infraestrutura metálica. Além disso, há pouca informação na literatura científica sobre os fatores que levam às fraturas das próteses fixas metalocerâmicas. Com isso, o presente estudo teve como objetivo avaliar se a quantidade de elementos que compõe uma prótese, se a quantidade de elementos por retentor, se o tipo de prótese, se o tipo de pilar, se a localização da prótese, se o bruxismo e se a utilização de placa miorrelaxante influenciam na incidência de fraturas em próteses fixas metalocerâmicas. Para este estudo, foram selecionados 16 pacientes, totalizando 74 próteses metalocerâmicas, instaladas entre 2000 e 2010, que tiveram um acompanhamento mínimo de 4 anos. Foram coletados dados, como: gênero, idade, data de instalação das próteses e sistema cerâmico utilizado. Foi realizada a avaliação clínica considerando integridade da prótese, características do elemento antagonista e coleta da história odontológica em caso de fratura, além de um questionário para identificar provável ou possível bruxismo. Foram determinadas as taxas de sucesso, insucesso e sobrevivência da mesma. Os resultados mostraram que a taxa de sucesso das próteses metalocerâmicas instaladas foi de 87,8% e a taxa de sobrevivência foi de 89,1%. Além disso, a taxa de sucesso não foi influenciada pela idade (p=0,903), tempo de instalação (p=0,830), número de próteses na boca (p=0,872), número de elementos (p=0,937) e número de pilares (p=0,064). Para as variáveis qualitativas também não houve diferença estatística significante (p>0,05) entre as proporções das taxas de sucesso e insucesso. Contudo, os resultados mostraram que pacientes que não usavam placa miorrelaxante tiveram taxa maior de sucesso que os pacientes usuários de placa (p=0,004). Assim, pode-se concluir que as próteses metalocerâmicas apresentam altas taxas de sucesso e sobrevida garantindo a longevidade desse tipo de reabilitação. / Metal-ceramic prosthesis are still the treatment choice in oral rehabilitation because they present high survival rates, even if the aesthetic can be compromised due to optical properties related to metallic infrastructure. In addition, there is little information on scientific literature about factors that lead to fractures of fixed metalceramic prosthesis. The purpose of this study was to evaluate if prosthesis elements number, number of elements per prosthetic abutment, type of prosthesis, type of prosthetic abutment, the prosthesis location, bruxism and myorelaxant plaque influences on incidence of fractures in fixed metal-ceramic prosthesis. For this study, 16 patients were selected totaling 74 metal-ceramic dentures installed between 2000 and 2010 with a follow-up of at least 4 years. Data were collected, such as: gender, age, prosthesis installation date and the ceramic system used. Besides a questionnaire to identify probable or possible bruxism, a clinical evaluation was performed to evaluate prosthesis integrity, antagonist element characteristics and dental history in case of fracture. Success, failure and survival rates were determined. The results showed that the success rate of metal-ceramic prosthesis was 87.8% and the survival rate was 89.1%. In addition, the success rate was independent of age (p=0.903), installation time (p=0.830), number of prosthesis (p=0.872), elements (p=0.937) and abutments (p=0.064). The qualitative variables also did not show significant statistical results (p> 0.05) between success and failure rates. However, the results showed that patients who did not use myorelaxant plaque had a higher success rate than plaque users (p=0.004). Thus, it can be concluded that the metal-ceramic prosthesis has high success and survival rates, ensuring longevity of this type of rehabilitation.
|
89 |
Resistência à corrosão de amálgamas e de liga à base de gálio, sem e com adesivos, através do método de perda de peso e análise da rugosidade de superfície.Abreu, Paulo Humaitá de 10 May 2002 (has links)
Avaliou-se a resistência à corrosão pelos testes de perda de peso em imersão alternada (solução-ar) e as conseqüentes alterações produzidas nas superfícies dos três materiais restauradores (os amálgamas Dispersalloy e Tytin Plus, ambos de alto conteúdo de cobre, respectivamente do tipo fase dispersa e do tipo partícula única, assim como a liga à base de gálio Galloy), não ou associados a dois sistemas adesivos (All-Bond 2 e PAAMA-2), observadas através da medição da rugosidade de superfície. Confeccionou-se dez corpos-de-prova, para cada condição específica, a partir de uma matriz metálica de aço inoxidável contendo cinco cavidades cilíndricas, com 10,7 mm de diâmetro por 3,0 mm de altura cada uma. Após o polimento, como é feito no caso de análises metalográficas, os espécimes foram pesados e levados ao rugosímetro para realizar as medições imediatamente. Estes foram submetidos à imersão alternada, na solução de sulfeto de sódio a 5 %, por um período de 24 horas e novamente foi realizada a pesagem e obtidos os valores de perda de peso. Depois da pesagem, os corpos-de-prova foram levados novamente ao rugosímetro para obtenção dos valores médios de rugosidade de superfície. Os resultados foram registrados e submetidos à análise de variância, a dois critérios, e ao teste de contrastes de Tukey-Kramer. Dos resultados obtidos, conclui-se que todos os espécimes perderam peso e tiveram sua rugosidade de superfície aumentada após a imersão em solução corrosiva; a liga Galloy mostrou valores maiores, tanto no método de perda de peso como no de rugosidade de superfície, quando comparada aos dois amálgamas; a liga Tytin Plus alcançou os melhores resultados; houve diferença estatisticamente significante entre os materiais restauradores, mas não entre os sistemas adesivos utilizados, mostrando comportamentos diferentes dependendo da combinação desses fatores. / The resistance to the corrosion was evaluated through weight loss to an alternated immersion (solution-air) and its consequent changes on the surface of three restoring materials (them amalgams Dispersalloy and Tytin Plus, both with high copper content, respectively dispersion phase and unique particle, as well as the alloy gallium base Galloy), associated or not to two adhesive systems (All-Bond 2 and PAAMA-2), observed by measuring the surface roughness. Ten bodies-of-test were made, for each specific condition, in a metallic matrix os stainlesss steel with five cilindrical cavities, measuring 10,7 mm in diameter and 3,0 mm thickness each one. After polishing, as in the metalographic anal ysis, the specimens were weighed and submitted to the roughness measurer to measuring inicial. These were submitted to an alternated immersion in 5 % sodium sulfide solution, for 24 hours and then the second weighting was performed and obtained the average values of weight loss. A second measure of the surface roughness was then performed. The results were registered and submitted to the variance analysis, to two approaches, and to the test of contrasts of Tukey-Kramer. From the obtained results, it was concluded that all specimens lost weight and there was an increasing roughness surface after immersion in corrosive solution; Galloy showed higher values, both weight loss test and the rougness surface, compared to two amalgams; the alloy Tytin Plus obtained better results; there was significant statistical difference among the restoring materials, but not among adhesive systems, showing different behaviors according to arrangement of these factors.
|
90 |
"Estudo da interface adesiva em restaurações que combinam resinas com diferentes módulos de elasticidade" / Evaluation of the adhesive interface of restorations combining composite resins with different elastic modulusKenshima, Silvia 11 December 2001 (has links)
O objetivo deste estudo foi o de avaliar uma técnica teste para inserção de resinas compostas combinadas e duas técnicas convencionais, quanto à qualidade da interface adesiva, em restaurações classe V realizadas em dentes bovi nos. Foram utilizadas as resinas compostas (Z-250 e Durafill VS) com o sistema adesivo (Single Bond) em 30 preparos confeccionados nas superfícies vestibulares dos dentes (fator C= 3). Portanto, foram analisadas seis técnicas r estauradoras com 5 repetições: incremental vertical (Z-v e D-v), incremental oblíqua (Z-o e D-o), e teste [Z-t e D-t (forramento das paredes cavitárias com uma resina e preenchimento com a outra)]. Os espécimes foram armazenado s por 24 h em água a '37 GRAUS'C e secionados no sentido V-L, originando 4 superfícies para obtenção de dados por espécime, as quais foram condicionadas (ácido fosfórico a 37%, por 3s) e coradas (azul de metileno a 0,5%, por 2s ). Para mensurar o comprimento (c) e a largura (l) dos gaps, a interface adesiva foi examinada por microscopia ótica (400X). A largura média ('mü'm) dos gaps foi calculada através da equação lm = 'sigma' ('c IND. n' x 'l IND. n ') / 'sigma' 'c IND. n'. Os resultados obtidos pelo tratamento estatístico dos dados (ANOVA para Medidas Repetidas) mostraram que somente a Técnica e a Superfície de leitura foram significativas (p < 0,05). Concluiu-se com base n estes resultados que a técnica teste apresentou qualidade de interface inferior, ou seja, gaps mais largos e que, a largura média dos gaps relativa à seção central foi maior que a das superfícies externas medidas / The objective of this study was to evaluate the quality of the adhesive interface of an experimental placement technique, which combines different composite resins, and two conventional techniques used in class V restorations i n bovine teeth. Two composite resins were applied in this study (Z-250 and Durafill VS) with the adhesive system (Single Bond) in 30 cavity preparations made on the labial surface of the teeth (C-factor = 3). So, six restorativ e techniques were applied with 5 samples each: incremental vertical (Z-v e D-v), incremental oblique (Z-o e D-o), and experimental [Z-e and D-e (lining the cavity walls with one of the resins and bulk filling with the other)]. After 24-hour-storage in water (37° C), each specimen was sectioned (LB) generating 4 surfaces for gap assessment that were previously acid etched (phosphoric acid 37% for 3s) and stained (metilene blue 0.5% for 2s). The adhesi ve interface was examined by optic microscopy at 400X and both length (l) and width (w) of gaps were measured (´mü´m). The mean gap widths were calculated by the equation w = ´sigma´ (´c IND.n´ x ´l IND.n´) / ´sigma´ ´c IND. n´ . The results obtained from the data's statistical analysis (ANOVA for Repeated Measurements) showed that only Technique and Surface were significant (p < 0,05). Based in this results it was concluded that the experimental techni que showed the worst interface quality, which means that gap widths were larger and that the gap width means of the central section were higher than the measured external ones
|
Page generated in 0.2696 seconds