• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 39
  • 8
  • 1
  • Tagged with
  • 48
  • 48
  • 34
  • 32
  • 23
  • 15
  • 13
  • 12
  • 12
  • 12
  • 11
  • 11
  • 11
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A clinical study of a resilient denture lining material

Hoke, James A. January 1976 (has links)
Thesis (M.S.)--University of Michigan, Ann Arbor, 1976. / Typescript (photocopy). Includes bibliographical references (leaves 48-49). Also issued in print.
2

A clinical study of a resilient denture lining material

Hoke, James A. January 1976 (has links)
Thesis (M.S.)--University of Michigan, Ann Arbor, 1976. / Typescript (photocopy). eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references (leaves 48-49).
3

Viscoelastic properties of soft liners and tissue conditioners a thesis submitted in partial fulfillment ... in dental materials ... /

Duran, Ricardo. January 1978 (has links)
Thesis (M.S.)--University of Michigan, 1978.
4

A clinical evaluation of resilient liners for dentures thesis submitted in partial fulfillment ... in denture prosthesis ... /

Aronis, Constantine B. January 1962 (has links)
Thesis (M.S.)--University of Michigan, 1962.
5

Padronização da metodologia para análise de sorção de água e solubilidade de materiais resilientes temporários para  base de prótese / Standardization of methodology for water sorption and solubility analysis of temporary resilient denture liners

Maciel, Janaina Gomes 08 June 2016 (has links)
Não existem normas internacionais que determinem limites aceitáveis de sorção de água e solubilidade para os materiais resilientes temporários para base de prótese, além de haver divergências metodológicas nos estudos. Objetivou-se avaliar de forma padronizada essas propriedades físicas para materiais macios de curta duração ao longo de sua vida útil. Corpos de prova (50mm x 0,5mm/ ISO-10139-2) de 7 condicionadores teciduais (Coe-Comfort-CC, Softone-ST, Rite-Line-RL, Dura Conditioner-DC, Hydro-Cast-HC, DentusoftDS e Visco-gel-VG) e 2 reembasadores resilientes temporários (Trusoft-TS e Coe-Soft-CS) foram individualmente confeccionados e submetidos à dessorção até estabilização das massas. Então, foram imersos em água destilada a 37oC por 3, 5, 7 ou 14 dias (n=10) para depois serem pesados, dessecados e pesados novamente. Os dados foram obtidos em porcentagens de sorção/solubilidade e analisados estatisticamente por ANOVA 2 fatores e teste de Tukey HSD (&#x3B1;=0,05). Em todos os períodos, VG (12,06±0,93 a 16,62±0,87%) apresentou a maior sorção de água dentre os materiais testados, sendo as menores porcentagens observadas para CC (2,23±0,53 a 2,99±0,49%) (P<0,05). CC, CS e TS não apresentaram alteração significativa da sorção de água ao longo de 14 dias (P>0,05). Já os demais materiais exibiram um aumento significativo da sorção de água entre os períodos de 7 e 14 dias (P<0,05). Para a solubilidade, valores médios inferiores e estatisticamente semelhantes foram apresentados pelos materiais DC, HC, DS, TS, RT e CS (0,28±0,30 a 2,13±0,23%) (P>0,05). ST (4,09±1,60 a 8,80±1,15%) demonstrou maior solubilidade que CC (1,89±0,30 a 3,35±0,70%), mas os mais altos valores percentuais dentre os materiais testados foram observados para VG (20,30±4,26 a 23,59±20,24%) (P<0,05). CC, DC, DS, HC, RT, TS e CS não apresentaram alterações na solubilidade percentual média ao longo dos 14 dias de avaliação. Já os condicionadores teciduais VG e ST exibiram aumento dos valores médios apenas aos 14 dias de imersão em água. Conclui-se que, ao longo da vida útil média de um condicionador tecidual (7 dias), os materiais CC, DC, HC, DS, RL, CS e TS apresentaram comportamento in vitro satisfatório em relação à sorção de água e solubilidade. De acordo com os resultados obtidos, os materiais CC, TS e CS foram considerados os mais indicados dentre os testados para reembasamento de próteses em até 14 dias. / There are no international standards that determine acceptable limits of water sorption and solubility for the temporary resilient liners, besides the differences in the methodology of the studies. It was aimed to evaluate in a standardized manner these physical properties of short-term soft materials throughout their lifespan. Specimens (50mm x 0.5mm/ ISO-10139-2) of 7 tissue conditioners (Coe-Comfort-CC, Softone- ST, Rite-Line-RL, Dura Conditioner-DC, Hydrocast-HC, Dentusoft-DS and Visco-gel- VG) and 2 temporary resilient liner (Trusoft-TS e Coe-Soft-CS) were individually prepared and submitted to desorption until mass stabilization. Afterwards, they were immersed in distilled water at 37oC for 3, 5, 7, or 14 days (n=10) to then be weighed, dried and reweighed. The data were obtained in percentages of sorption/solubility and statistically analyzed by 2-way ANOVA and Tukeys test (&#x3B1;=0.05). In all periods, VG (12.06±0.93 to 16.62±0.87%) showed the highest water sorption among the tested materials, with the lowest percentages observed for CC (2.23±0.53 to 2.99±0.49%) (P<0.05). CC, CS and TS showed no significant changes in water sorption over 14 days (P>0.05). The other materials exhibited a significant increase in water sorption between the periods of 7 and 14 days (P<0.05). For the solubility, lower (and statistically similar to each other) values were presented by DC, HC, DS, TS, RT, and CS materials (0.28±0.30 to 2.13±0.23%) (P>0.05). ST (4.09±1.60 to 8.80±1.15%) showed higher solubility than CC (1.89±0.30 to 3.35± 0,70%), but the highest percentages among tested materials were observed for VG (20.30±4.26 to 23.59±20.24%) (P<0.05). CC, DC, DS, HC, RT, TS, and CS showed no changes in the mean percentage solubility throughout the 14-day trial. The tissue conditioners VG and ST exhibited increased average values only at 14 days of water immersion. It was concluded that, over the lifespan of a tissue conditioner (7 days), the materials CC, DC, HC, DS, RL, CS, and TS presented suitable in vitro performance with respect to water sorption and solubility. According to the results, the materials CC, TS, and CS were considered best suited among the tested materials for denture relining of up to 14 days.
6

A clinical evaluation of silicone rubber as a denture base lining material a thesis submitted in partial fulfillment ... denture prosthesis ... /

Sauer, John L. January 1964 (has links)
Thesis (M.S.)--University of Michigan, 1964.
7

A clinical evaluation of silicone rubber as a denture base lining material a thesis submitted in partial fulfillment ... denture prosthesis ... /

Sauer, John L. January 1964 (has links)
Thesis (M.S.)--University of Michigan, 1964.
8

Efeito das técnicas de desinfecção sobre a dureza e rugosidade superficial dos materiais reembasadores

Pavan, Sabrina [UNESP] 18 February 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:55Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-02-18Bitstream added on 2014-06-13T19:16:52Z : No. of bitstreams: 1 pavan_s_me_arafo.pdf: 776969 bytes, checksum: 2a333e8745a98776862d0b115402f9c3 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste estudo foi avaliar o efeito de técnicas de desinfecção utilizando soluções de glutaraldeído 2%, hipoclorito de sódio 5%, clorexidina 5% e energia por microondas sobre a dureza e rugosidade de superfície dos materiais reembasadores macios Ufi Gel , Molloplast-B, Eversoft e Mucopren soft. Quarenta corpos-de-prova de cada material com dimensões de 36x7x6 mm foram processados em muflas plásticas para microondas e polimerizados de acordo com as recomendações dos fabricantes. As amostras foram divididas em grupos (n=10) e submetidas à desinfecção por 10 minutos nas soluções químicas e, em forno de microondas doméstico por período de 3 minutos à 500W. As leituras de dureza e rugosidade foram realizadas 24 horas após a confecção dos corpos de prova e após aplicação do 1° e 2° ciclo de desinfecção, respectivamente. As leituras de dureza foram realizadas sobre uma das faces do corpo de prova com auxílio de durômetro Shore A. Sobre a face oposta foram realizadas as leituras de rugosidade com rugosímetro Surf-Corder SE 1700. Os dados obtidos foram submetidos à análise de variância e teste de Tukey ao nível de significância de 1%. Conclui-se que a aplicação de dois ciclos de desinfecção não produziu alterações na dureza dos materiais utilizados. Porém, houve diminuição na rugosidade após o primeiro ciclo de desinfecção. A técnica de desinfecção com solução de glutaraldeído 2% promoveu os maiores valores de dureza nos materiais Molloplast-B, Mucopren soft e Ufi Gel. Já o material Eversoft não apresentou alteração nos valores de dureza e rugosidade de superfície em nenhuma das técnicas de desinfecção. / The aim of this study was to assess the effect of disinfections with 2% glutaraldehyde, 5% sodium hypoclorite, 5% chlorhexidine solution and microwave oven on hardness and roughness of soft denture liners Ufi Gel, Molloplast-B, Eversoft and Mucopren soft. Forty samples (36x7x6 mm) of each material were processed in special microwave flasks according to manufacturers' recommendation. Ten specimens of each material were immersed in each disinfectant solution for ten minutes or placed in a microwave oven for 3 minutes at 500W. The surface roughness and hardness values were recorded after 24 hours (control), and also at each two cycles of disinfection. Hardness readings were made on the sample surface with Shore A durometer according to the ASTM D-2240 specifications. The surface roughness was verified on the other surface using a Surf-Coder SE 1700 perfilometer. Data were submitted at analysis of variance and Tukey's test to 1% of level. The application of two disinfection cycles did not change the hardness values significantly. However, after the first cycle of disinfection, means of surface roughness were lower than those observed for the control. The glutaraldehyde solution promoted the highest values of hardness on Molloplast-B, Mucopren soft and Ufi Gel materials. The Eversoft did not show changes in hardness and surface roughness independent of disinfection technique.
9

Efeito do tempo e da desinfecção por micro-ondas no desempenho clínico e na quantificação de micro-organismos de um reembasador rígido /

Ribeiro, Roberta Chuqui. January 2009 (has links)
Resumo: Este estudo avaliou o efeito da desinfecção por micro-ondas sobre o desempenho clínico e a quantificação de micro-organismos de um reembasador rígido em diferentes intervalos de tempo. Foram selecionados 40 pacientes de ambos os sexos com idade entre 30 e 75 anos, utilizando prótese total superior com necessidade de reembasamento. Essas próteses foram reembasadas com o material Tokuyama Rebase II. Logo após o reembasamento, foi avaliado o escoamento e a lisura do material, classificando-os em satisfatório ou insatisfatório. Em seguida, a amostra foi separada em dois grupos: grupo GC (controle) - os pacientes higienizaram sua prótese três vezes ao dia por meio de escovação com sabão de coco. Além disso, a prótese foi retirada durante a noite, ficando imersa em água e grupo GD (desinfecção por micro-ondas) - nesse grupo, além da escovação com escova dental macia e sabão de coco, foi realizada a desinfecção da prótese por micro-ondas uma vez por semana utilizando a potência de 650W e o tempo de 3 minutos. No período noturno, a prótese também foi imersa em água. O material reembasador foi avaliado por dois profissionais treinados trabalhando separadamente após 7 dias, 15 dias, 1 mês, 3 meses, 6 meses, 9 meses e 1 ano. Foram analisadas as seguintes características: estabilidade de cor, brilho, descoloração ou manchamento, irritação dos tecidos orais, separação ou fratura do material e rugosidade superficial. Além disso, foi realizada a quantificação de micro-organismos presentes na superfície interna da prótese em todos os períodos experimentais. Os dados obtidos foram analisados por análise de variância e pelos testes de Tukey e Friedman, ao nível de significância de 5%. O material apresentou lisura e escoamento satisfatórios em todas as análises após o reembasamento. As próteses reembasadas submetidas à desinfecção... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of disinfection method on the clinical performance and quantification of microbial of a hard chairside reline resin after 1-year service period. Forty adult patients aged between 30 and 75 years, who required denture reline treatment, participated in this study. Tokuyama Rebase II was used to reline complete maxillary dentures. Immediately after the reline, assessment of the flow and smoothness was rated by the clinician as satisfactory and unsatisfactory. The edentulous subjects were randomly divided into 2 groups (n=20) and dentures were cleansed according to two methods: CG (control group)- brushing with coconut soap and soft toothbrush; DG (disinfection group)-brushing according to previous methods and microwave disinfection once a week for 3 min at 650W. Furthermore, all dentures were immersed in water at night. Evaluations were conducted by two examiners working separately. Color stability, gloss, staining or material discoloration, irritation to oral tissue, detachment or frature of material and surface roughness were assessed at 7 and 15 days, 1, 3, 6 and 9 months and 1 year post-placement. Quantitative microbial cultures were taken from the tissue side of each maxillary denture at all experimental periods. The data were analyzed by ANOVA and Friedman and Tukey tests. A 95% confindence level was used. Flow and smoothness of the material during relining were considered to be good or satisfactory in all the cases. Values color alterations of DG were significantly lower than those of CG (P<0.05). Color change observed after 15 days are greater than values obtained at 7 days recall (P<0.05). All color changes observed for the CG were considered noticeable (between 1.5 and 3.0 NBS). In disinfection group, color change was slight (between 0.5 and 1.5 NBS). There were statistically significant... (Complete abstract click electronic access below) / Orientador: Eunice Teresinha Giampaolo / Coorientador: Carlos Eduardo Vergani / Banca: Ana Cláudia Pavarina / Banca: Ana Lúcia Machado / Banca: Helena de Freitas Oliveira Paranhos / Banca: Marcelo Ferraz Mesquita / Doutor
10

Avaliação dos elementos finitos de tensões no tecido ósseo peri-implantar durante a osseointegração / Finite element analysis of stresses in peri-implant bone tissue during osseointegration

Santos, Mateus Bertolini Fernandes dos, 1985- 02 September 2011 (has links)
Orientador: Rafael Leonardo Xediek Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T13:50:15Z (GMT). No. of bitstreams: 1 Santos_MateusBertoliniFernandesdos_D.pdf: 5044188 bytes, checksum: b81a4d5dccdc37cad705fb6ddaf4b97c (MD5) Previous issue date: 2011 / Resumo: Forças aplicadas por próteses totais a implantes submersos durante o período deosseointegração podem, em alguns casos, levar ao insucesso clínico. Até o momento não existe trabalho na literatura que quantifique e/ou verifique a distribuição das forças mastigatórias em implantes submersos durante a ação mastigatória de próteses totais convencionais usadas provisoriamente durante o período de osseointegração. Dessa forma, neste trabalho foram avaliadas as tensões geradas no tecido ósseo subjacente a implantes recém-colocados, em diferentes situações, durante a ação mastigatória em próteses totais convencionais provisórias inferiores, por meio da metodologia dos elementos finitos. Com software de modelagem 3-D (SolidWorks 2010, SolidWorks Corp., Concord, Massachusetts, EUA) foram confeccionados modelos tridimensionais de mandíbula simulando diferentes situações clínicas: (1) implantes submersos, próteses totais convencionais e próteses reembasadas com diferentes materiais reembasadores macios; (2) diferentes níveis de altura de exposição dos cicatrizadores (submerso, nível gengival, 1,5 mm exposto no meio bucal); e (3) diferentes espessuras e comparação entre reembasamento na base da prótese inteira ou somente na região dos implantes. As análises foram realizadas em software específico (ANSYS Workbench 12, Ansys Inc., Canonsburg, Pennsylvania, EUA) e para cada modelo foram simuladas duas situações, com aplicação de carga mastigatória em canino inferior direito (35N) e primeiro molar inferior direito (50N). Todas as análises foram realizadas em tensão máxima principal, em MPa. Os resultados obtidos demonstraram que o reembasamento da prótese com material macio reduziu a concentração de tensões no tecido ósseo peri-implantar, sendo a concentração de tensão diretamente relacionada com a maciez do material. Os cicatrizadores submersos foram os que apresentaram menor valor de concentração de tensões. A espessura e área de reembasamento estão relacionadas à transmissão de tensões ao osso peri-implantar, quando o reembasamento da região dos implantes com espessura de 3 mm apresentou melhores resultados. Comparando-se os resultados mostrados nas diferentes simulações conclui-se que a situação que promoveu menor concentração de tensões no osso peri-implantar foi com implantes submersos, reembasamento realizado somente na região dos implantes, espessura de 3 mm e material macio. / Abstract: Forces applied to submerged implants from complete dentures during the osseointegration period can, in some cases, lead to clinical failure. To date there is no study in the literaturethat quantifies and/or verifies the stress distribution of occlusal forces in submerged implants during the masticatory function of conventional complete dentures used on an interim basis during the period of osseointegration. Thus, this study evaluated the stresses in the bone adjacent to newly placed implants during the masticatory function in conventional complete dentures through the finite element methodology. Using a 3-D modeling software (SolidWorks 2010, SolidWorks Corp., Concord, Massachussets, EUA) it were made tridimensional models of a mandible simulating different clinical situations: (1) submerged implants, conventional complete dentures and relined ones with different soft liner materials; (2) different height levels of exposure to the oral environment (submerged, gingival level and 1.5mm of exposure to the oral environment); and (3) different thickness and comparation between relining the entire base or only in the region near the implants. The analysis were made in a specific software (ANSYS Workbench 12, Ansys Inc., Canonsburg, Pennsylvania, EUA) and for each model it were simulated two situations with masticatory load in inferior right canine (35N) and inferior right first molar (50N). All the analysis were made in maximum principal stress, in MPa. The obtained results showed that relined dentures with soft liner material reduced the stress concentration in the peri-implant bone tissue, being the stress concentration directly related to the softness of the material. Submerged implants presented the lowest values of stress concentration in the peri-implant bone tissue. The thickness and the area of reline are related to the transmission of stress to the peri-implant bone tissue, when relining the denture only in the region of the implants with a 3-mm thick layer of soft liner material presented better results. Comparing the results obtained from the different simulations it is possible to conclude that the situation which promoted fewer stress concentration in the peri-implant bone was with submerged implants, relining made only in the implants region, thicker layer (3 mm) of reline and softer material. / Doutorado / Protese Dental / Doutor em Clínica Odontológica

Page generated in 0.0519 seconds