• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • 1
  • Tagged with
  • 20
  • 20
  • 12
  • 10
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Aplicação de técnicas de elementos finitos para mapeamento de campos elétricos sobre cavidades internas a isoladores poliméricos de 13.8 KV

SILVA, Suelen Holder de Morais e 21 June 2013 (has links)
Submitted by Daniella Sodre (daniella.sodre@ufpe.br) on 2015-04-17T13:50:00Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) DISSERTAÇÃO Suelen Holder de Morais e Silva.compressed.pdf: 3104256 bytes, checksum: c6c60b6a54b82f4cb45a7ce2e70088ad (MD5) / Made available in DSpace on 2015-04-17T13:50:00Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) DISSERTAÇÃO Suelen Holder de Morais e Silva.compressed.pdf: 3104256 bytes, checksum: c6c60b6a54b82f4cb45a7ce2e70088ad (MD5) Previous issue date: 2013-06-21 / CNPq / Um dos problemas relacionados com a interrupção do fornecimento de energia elétrica é o colapso do sistema de isolamento das linhas de distribuição. Com o avanço tecnológico foram adotados novos materiais, como o polímero, que possuem características superiores aos já utilizados. No entanto, esses isoladores, em seu processo de fabricação, vêm apresentando cavidades em seu interior. Essas cavidades podem ser responsáveis pelo desgaste prematuro do isolador, já que, no interior delas podem ocorrer descargas parciais. Com o objetivo de identificar a possibilidade do surgimento dessas descargas foi analisada uma amostra de 85 isoladores poliméricos na classe de tensão de 15 kV, os quais apresentam cavidades internas. As análises foram realizadas utilizando-se resultados de ensaios de raios X para dimensionamento das cavidades e software de elementos finitos para mapeamento dos campos elétricos. Essas análises tiveram como objetivo a classificação da amostra em dois grupos, sendo o primeiro relacionado com os que apresentam condições propícias ao surgimento de descargas, e o segundo associado a isoladores nos quais as condições impostas não se apresentam propícias ao surgimento das mesmas. Com base nesta classificação e utilizando como dados registros de ultrassom obtidos em laboratório, seria desenvolvido um novo processo de diagnóstico, com o auxílio de técnica de reconhecimento de padrões, no entanto os resultados obtidos indicaram que os campos elétricos impostos às cavidades não são suficientes para iniciar descargas parciais internas, inviabilizando a concepção do processo de diagnóstico.
2

[en] A STUDY RELATED WITH THE ISOLATION CONDITION OF HIGH TENSION ROTATING ELECTRIAL MACHINES / [pt] ESTUDO SOBRE O ESTADO DO ISOLAMENTO DE MÁQUINAS ELÉTRICAS ROTATIVAS DE ALTA TENSÃO

HELIO DE PAIVA AMORIM JUNIOR 14 December 2005 (has links)
[pt] O Monitoramento do Sistema de Isolamento em Máquinas Elétricas de Alta Tensão representa um avanço no que diz respeito ao planejamento operacional de uma indústria. Com posse de dados on-line referentes às condições apresentadas pelos isolamentos, as devidas precauções podem ser tomadas, evitando danos maiores. O trabalho apresentado tem como objetivo principal analisar um sistema de monitoramento desenvolvido pela CEA (Canadian Electrical Association), com suporte técnico da Ontario Hydro. O sistema chamado PDA (Partial Discharge Analyzer) mede, através de acopladores permanentes ou portáteis (capacitores), as Descargas Parciais nos enrolamentos estatóricos de grande máquinas de alta tensão. A quantificação exata das Descargas Parciais são indicadas das reais condições do isolamento. A análise do aparelho foi realizada em conjunção aos dados obtidos, tendo como referência a Companhia Siderúrgica Nacional (CSN). A partir de tais dados, é possível demostrar em que estágio atual de aproveitamento estamos em relação à utilização de tal aparelho e quais são os passos futuros para melhor compreensão das medidas. / [en] The Monitoring of te Isolation System in High Tension Electrical Machines represents na advance in what concerns the operational planning of na industry. Knowing the on- line data referring to the conditions presented by the isolations, the necessary cautions can be taken, avoiding bigger damages. This work has as the main aim to analyze a monitoring system developed by the CEA (Canadian Electrical Association). The system is called PDA ( Partial Discharge Analyzer) and measures, through permanent or portable couplers (capacitors), the Partial Discharges is indicator of the isolation real conditions. The appliance analyses was made with the obtained data, having as reference the CSN. With this data, it is possible to show in what profiting stage of appliance and which are the future steps for a better comprehension of the measures.
3

Estudo dos piezoeletretos na detecção de descargas parciais em transformadores / Study of piezoelectrets for detecting partial discharge in transformers

Gutnik, Yvan 25 April 2014 (has links)
A detecção de descargas parciais em transformadores consiste em importante metodologia de manutenção preventiva e preditiva. Neste contexto, a proposta desta pesquisa com o uso de sensores acústicos de piezoeletreto apresenta-se como um tema original e altamente relevante no desenvolvimento da tecnologia brasileira. A multidisciplinaridade do tema exigiu a realização de uma extensa pesquisa bibliográfica envolvendo os temas descargas parciais, métodos de detecção das descargas, piezeletricidade, eletretos, piezoeletretos, técnicas de manufatura do piezoeletreto proposto para a detecção de descargas e ferramentas de processamento de sinais, sendo a principal a deconvolução homomórfica. O Trabalho evoluiu para a elaboração de um primeiro protótipo laboratorial, constituído basicamente de um sensor piezoeletreto e um circuito amplificador, ambos abrigados em um invólucro metálico para assegurar uma blindagem eletromagnética. Os primeiros ensaios, em face da característica \"sui generis\" do protótipo, apontaram para a necessidade de novos circuitos e aprimoramento das metodologias desses ensaios laboratoriais, as quais também fazem parte do escopo deste trabalho. O desenvolvimento de um sistema de alta tensão autônomo, eletromagneticamente blindado e gerador de descargas elétricas impulsivas é um exemplo dos circuitos mencionados. A nova metodologia de testes buscou apresentar a evolução do comportamento acústico de uma descarga em diferentes ambientes, isto é, desde sinais sem ecos até sinais carregados com ecos e distorcidos pelo meio. Finalizando o trabalho, outra contribuição importante foi a decisão de analisar os sinais acústicos das descargas parciais pela deconvolução homomórfica, que mostrou ser essencial na remoção de ecos e na reconstrução do sinal acústico original. / Partial discharges acoustic detection is a very important preventive and predictive maintenance tool for transformers. In this research, a new acoustic piezoelectric sensor, based in Brazilian technology, was presented. However, before the construction of the prototype, an extensive literature was analyzed, including partial discharge, methods of discharges detection, piezoelectricity, electrets, piezoelectrets, manufacturing of the piezoelectret proposed to detection of discharges and signal processing tools, in special the homomorphic deconvolution. Basically, the prototype developed consists of a piezoelectret sensor and an amplifier circuit, assembled in a special metallic box, to shield any electromagnetic interference. During the tests, it was detected the need to create new circuits and to improve laboratory methodologies. A new impulse high-voltage generator electromagnetically shielded can be cited as an example of these circuits here developed. The new testing methodology aimed to present the evolution of the acoustic behavior of a discharge in different environments, in other words, from signals without echoes to signals containing echoes and distorted by the environment. In the processing signals context, another important contribution was the decision to analyze the acoustic signals of partial discharges by homomorphic deconvolution, which has allowed the reconstruction of the original acoustic signal without echo.
4

Estudo dos piezoeletretos na detecção de descargas parciais em transformadores / Study of piezoelectrets for detecting partial discharge in transformers

Yvan Gutnik 25 April 2014 (has links)
A detecção de descargas parciais em transformadores consiste em importante metodologia de manutenção preventiva e preditiva. Neste contexto, a proposta desta pesquisa com o uso de sensores acústicos de piezoeletreto apresenta-se como um tema original e altamente relevante no desenvolvimento da tecnologia brasileira. A multidisciplinaridade do tema exigiu a realização de uma extensa pesquisa bibliográfica envolvendo os temas descargas parciais, métodos de detecção das descargas, piezeletricidade, eletretos, piezoeletretos, técnicas de manufatura do piezoeletreto proposto para a detecção de descargas e ferramentas de processamento de sinais, sendo a principal a deconvolução homomórfica. O Trabalho evoluiu para a elaboração de um primeiro protótipo laboratorial, constituído basicamente de um sensor piezoeletreto e um circuito amplificador, ambos abrigados em um invólucro metálico para assegurar uma blindagem eletromagnética. Os primeiros ensaios, em face da característica \"sui generis\" do protótipo, apontaram para a necessidade de novos circuitos e aprimoramento das metodologias desses ensaios laboratoriais, as quais também fazem parte do escopo deste trabalho. O desenvolvimento de um sistema de alta tensão autônomo, eletromagneticamente blindado e gerador de descargas elétricas impulsivas é um exemplo dos circuitos mencionados. A nova metodologia de testes buscou apresentar a evolução do comportamento acústico de uma descarga em diferentes ambientes, isto é, desde sinais sem ecos até sinais carregados com ecos e distorcidos pelo meio. Finalizando o trabalho, outra contribuição importante foi a decisão de analisar os sinais acústicos das descargas parciais pela deconvolução homomórfica, que mostrou ser essencial na remoção de ecos e na reconstrução do sinal acústico original. / Partial discharges acoustic detection is a very important preventive and predictive maintenance tool for transformers. In this research, a new acoustic piezoelectric sensor, based in Brazilian technology, was presented. However, before the construction of the prototype, an extensive literature was analyzed, including partial discharge, methods of discharges detection, piezoelectricity, electrets, piezoelectrets, manufacturing of the piezoelectret proposed to detection of discharges and signal processing tools, in special the homomorphic deconvolution. Basically, the prototype developed consists of a piezoelectret sensor and an amplifier circuit, assembled in a special metallic box, to shield any electromagnetic interference. During the tests, it was detected the need to create new circuits and to improve laboratory methodologies. A new impulse high-voltage generator electromagnetically shielded can be cited as an example of these circuits here developed. The new testing methodology aimed to present the evolution of the acoustic behavior of a discharge in different environments, in other words, from signals without echoes to signals containing echoes and distorted by the environment. In the processing signals context, another important contribution was the decision to analyze the acoustic signals of partial discharges by homomorphic deconvolution, which has allowed the reconstruction of the original acoustic signal without echo.
5

Contribuição para o desenvolvimento de um sistema de monitoração via satélite do estado de poluição de cadeias de isoladores de alta tensão

LIMA, Ricardo Ataíde de 31 January 2010 (has links)
Made available in DSpace on 2014-06-12T17:36:05Z (GMT). No. of bitstreams: 2 arquivo2529_1.pdf: 5942799 bytes, checksum: 7fec93a7eb63a4c46adc5d5195e570a4 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2010 / Fundação de Amparo à Ciência e Tecnologia do Estado de Pernambuco / O presente trabalho relata algumas contribuições para o desenvolvimento de um sistema completo de monitoração em tempo real do estado de poluição de cadeias de isoladores de linhas de transmissão de alta tensão. Essa condição é inferida indiretamente pelo sistema com base na contagem de descargas parciais ocorrendo na superfície dos isoladores, bem como no nível de umidade e temperatura ambiente. O sistema é composto por um sensor óptico conectado a uma fibra óptica, um módulo de processamento microcontrolado, um sistema de alimentação fotovoltaico e um sistema de comunicação via satélite. É verificado se a corrente de fuga excedeu um dos quatro limiares estabelecidos que são de 5 ,10, 20 e 40 mA e a taxa com que isso ocorre, além dos valores de temperatura e umidade relativa. As informações obtidas são processadas e armazenadas pelo microcontrolador PIC 16F877A e transmitidas pelo sistema de comunicação via satélite. É realizado o download das informações transmitidas para um banco de dados relacional e essas informações disponibilizadas em uma página web, e representadas graficamente ou em formato tabular. Seis sistemas foram instalados em torres de alta tensão da CHESF para a realização de estudos de correlação entre os parâmetros registrados e o grau de poluição, este obtido a partir de inspeções nos pontos de monitoramento por parte dos técnicos de manutenção da empresa. As contribuições específicas do presente trabalho incluem estudos dos efeitos degradantes da poluição no desempenho de isoladores de alta tensão, o projeto e implementação do módulo de processamento e do protocolo de comunicação por satélite do sistema, bem como a análise do desempenho do sistema e dos parâmetros medidos nos seis sistemas instalados em pontos da rede de transmissão da CHESF
6

Método espectral para localização de múltiplas descargas parciais na parte dielétrica de bobinas de hidrogeradores

MODESTO, Jonathas Felippe Morais 18 August 2014 (has links)
Submitted by Hellen Luz (hellencrisluz@gmail.com) on 2017-10-02T17:32:40Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_MetodoEspectralLocalizacao.pdf: 36751428 bytes, checksum: 91ff2c96311b8efad399a416dbaad775 (MD5) / Rejected by Edisangela Bastos (edisangela@ufpa.br), reason: on 2017-10-10T17:02:37Z (GMT) / Submitted by Hellen Luz (hellencrisluz@gmail.com) on 2017-10-16T14:15:49Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_MetodoEspectralLocalizacao.pdf: 36751428 bytes, checksum: 91ff2c96311b8efad399a416dbaad775 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-11-13T15:52:43Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_MetodoEspectralLocalizacao.pdf: 36751428 bytes, checksum: 91ff2c96311b8efad399a416dbaad775 (MD5) / Made available in DSpace on 2017-11-13T15:52:44Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_MetodoEspectralLocalizacao.pdf: 36751428 bytes, checksum: 91ff2c96311b8efad399a416dbaad775 (MD5) Previous issue date: 2014-08-18 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Neste trabalho, é estabelecida uma metodologia baseada em análise espectral para localização de múltiplas descargas parciais na região dielétrica de bobinas de hidrogeradores. Esta localização de várias descargas objetiva viabilizar diagnóstico preventivo da região isolante da bobina. É concebido um modelo computacional utilizando-se o método das diferenças finitas no domínio do tempo para solucionar numericamente as equações de Maxwell, o qual é validado experimentalmente. O campo elétrico transitório associado a descargas parciais que ocorrem em diferentes posições da bobina é registrado e seu espectro, após processamento e análise estatística, é utilizado para realizar o diagnóstico. Em aproximadamente 90% das simulações realizadas, estimativas precisas da localização das descargas foram obtidas. Um novo método de injeção de sinais de descargas parciais também foi desenvolvido neste trabalho. / A methodology based on spectral analysis is established for performing localization of multiple partial discharges in dielectric region of hydro-generators coils. This pinpointing of multiple discharges aims to provide means for performing preventive diagnosis of the insulating region of the referred coil. A computer model of the structure was conceived by using the finite-difference time-domain method (FDTD-3D) to numerically solve Maxwell’s equations, which is experimentally validated. The transient electric field associated with partial discharges that occur at different positions of the coil is calculated and its spectrum, after processing and statistical analysis, is used to perform the diagnosis. In approximately 90% of simulations, accurate estimates of simultaneous discharges location were obtained. Transient numerical results are in agreement with literatures measurements performed experimentally. A new method of injection of partial discharge signals was also developed in this work.
7

[en] A DIAGNOSTICS SYSTEM OF HIGH VOLTAGE POWER APPARATUS BASED IN PARTIAL DISCHARGES OCURRENCE / [pt] UM SISTEMA DE DIAGNÓSTICO DE EQUIPAMENTOS ELÉTRICOS DE ALTA TENSÃO COM BASE NA OCORRÊNCIA DE DESCARGAS PARCIAIS

HELIO DE PAIVA AMORIM JUNIOR 13 December 2001 (has links)
[pt] Os equipamentos elétricos de alta tensão são peças fundamentais na produção industrial. Porém, os sistemas de isolamento são os que mais apresentam problemas ao longo da vida útil dos nossos equipamentos. Suas propriedades dielétricas são alteradas ao longo do tempo e, desta forma devem ser monitoradas. Dentre as principais anomalias acometidas aos sistemas de isolamento, estão as Descargas Parciais (DP).Elas são resultado do rompimento da rigidez dieétrica do material isolante submetido a um intensivo campo elétrico . Até alguns anos atrás, em virtude da existência dos mecanismos de medição que possibilitassem o armazernamento de dados, muito pouco se efetuava para o acompanhamento das condições apresentadas pelos sistemas de isolamento.Com advento de sistemas digitais,esta limitação foi vencida. No entanto, a obtenção de dados reais e sua posterior avaliação são mecanismos que ainda carecem de um bom número de anos de experiência para sua elucidação. Esse fato advém,principalmente, da dificuldade em obtê-los .Como forma de contornar problema de falta de dados reais, foram desenvolvidas as célualas que têm como características simular os principais tipos de defeitos existentesnos sistemas de isolamento de alta tensão.Essas células são isoladas por materiais dielétricos idênticos ao que são usados em equipamentos elétricos reais. Dessa forma, foi possível a simulação de defeitos e a posterior aquisição, através do método eletromagnético de medição de DP, de um número suficiente de dados. Esses dados foram,então, aplicados no ajuste do sistema de reconhecimento de padrões de DP, onde se faz uso da teoria fractal, como um mecanismo de compactação de dados, por meio das grandezas fractais denominadas de dimensão fractal e lacunaridade, e também das redes neurais artificiais, com a utilização de um algoritmo supervisionado através do modo de treinamento back-propagation.Essa etapa,denominada de laboratorial, foi de fundamental importância para obtenção de conhecimento experimental bastante útil para a aplicação em ambientes reais.Outra fonte de informação também foi disponibilizada e se refere aos níveis de gases encontrados nas amostras de óleo colhidas junto aos transformadores de potência. Esta análise, conhecida como análise cromatográfica,baseia-se na existência de determinados tipos de gases para apontar o tipo de anomalia acometida ao sistema de isolamento do equipamento elétrico.Embora existam alguns métodos capazes de realizar tal diagnóstico, a tese fez uso das informações de um especialista.Essas afirmações foram então empregadas em um sistema neuro-fuzzy hierárquico, que tem como fundamento a extração de regras que relacionam os níveis de gases obtidos pela cromatografia gasosa com o tipo de anomalia existente no sistema de isolamento .Após esse processo um conjunto de transformadores de potência reais foi monitorado através de técnicas de cromatografia e do método eletromagnético.As duas técnicas, portanto, são usadas para estimar a ocorrência de DP nos sistemas de isolamento e, cosequentemente, o nível de degradação dos mesmos.Desta forma, a tese apresenta um sistema de diagnóstico que se utilizada de dados internos ao sistema de isolamento dos equipamentos elétricos baseados na ocorrência de DP. Esse sistema indica, ao seu final, um conceito sobre o atual estado operativo do mesmo, podendo este ser utilizado em um planejamento mais adequado que previna perdas intempestivas. A avaliação de desempenho do modelo, tanto laboratorial quanto em campo, apresentou ídices elevados, culminando em uma confirmação visual interna de um equipamento real, que comprova a eficiência e a importãncia do sistema. / [en] High voltage (HV) power apparatus are fundamental parts in the industrial process. It is also well Known that electrical insulation systems are the parts that present more problems through the life cycle of an HV apparatus. The dielectric properties of materials are altered during operation time and for this reason they should be monitored. Among the main anomalies that can affect the insulation systems are the Partial Discharges (PD). They are result of a partial failure of the dielectric rigidity of the insulating material submitted to an intense electric field.Until recently, probably due to the inexistence of measurement mechanisms that made possible the storage of data, very a little could be done to accompany the actual condition of insulation systems. With the coming of digital systems, this limitation was overcome.However, the obtention of real data and their subsequent evaluation are mechanisms that still will demand a good number of years of experience to perfect . This fact occurs, mainly, due to the difficulty in obtaining those data .As a way to the problem of lack of real data, special cells development with the purpose of simulating the principal types of defects that occur in HV insulation equipment . In that way, it was possible to do both the simulation of the defects and the measurement and acquisition, through the electromagnetic measurement method, of an expressive number of data. Those data were used to adjust a system of pattern recognition of PD, using artificial neural networks, where it is also made use of the fractal theory, as a mechanism of data compression, by measures of fractal dimension and lacunarity. That stage, denomited laboratory, was of fundamental importance to the obtention of experimental . Knowledge very useful to the development of real operating systems .Another source of information that was also available refers to the levels of gases found in oil samples from the interior of power transformers. This analysis, known as analysis of dissolved gases or chromatography, is based on the existence of certain types of gases as an indication of the type of anomaly on the electrical insulation system. Although some mehods exist, capable of accomplishing such diagnosis, the thesis made use of a specialist`s information. Those statements were used then in a hierarchical neuro-fuzzy model, designed method, with the type of anomaly existent in the insulation system. After that process, a real sample of operating HV power apparatus was monitored using the two analysis techniques, the chromatography and the electromagnetic method of PD measurement.Therefore these two techniques, are used to estimate the PD activity in the insulation systems and, consequently, their level of degradation . In resume the thesis presents a diagnosis system that makes use of internal data from the electrical insulation system with base in the PD occurrence. That system indicates, at the end, a concept of its current operative state, being able to be used in a more appropriate planning in order to prevent inopportune losses. The evaluation of the model, as much of simulating as in field, present high indexes and a visual confirmation intern of a real equipment, that proves the efficiency and the importance of system.
8

Detecção acústica de descargas parciais com transdutor piezoelétrico / Acoustic detection of partial discharges with piezoelectrets transducers

Palitó, Thamyres Tâmulla Cavalcante 12 March 2015 (has links)
Os equipamentos elétricos instalados em linhas de transmissão e distribuição de energia são normalmente submetidos a condições anormais e intensos campos elétricos, que, eventualmente, levam, entre outros fenômenos, as descargas parciais (DPs). Estas descargas têm sido apontadas como uma das principais causas de falhas de equipamentos e envelhecimento precoce. Portanto, detectar DPs se tornou uma questão importante na busca de uma energia elétrica eficiente e confiável. No que se refere a detecção de DPs existem vários sensores que podem ser aplicados, a exemplos: óptico, magnético ou acústico, e cada um deles apresentando vantagens particulares e limitações. Uma das desvantagens de tais sensores é o custo elevado, o que restringe o monitoramento de DPs no âmbito da distribuição de energia mais especificamente em transformadores de potência. Embora, se o foco do monitoramento é apenas detectar a ocorrência de DPs, uma nova classe de sensores acústicos implementados com piezoeletretos pode ser uma alternativa econômica viável. Deste modo, nesta dissertação, foi investigado o comportamento acústico de tais transdutores expostos a diferentes condições de DPs, onde o sensor piezoelétrico foi utilizado na detecção de DPs produzidas por uma configuração de eletrodos ponta - ponta separados por diferentes gaps de ar (único ou múltiplo) e excitado por altas tensões alternadas. As amplitudes dos sinais registrados foram correlacionadas com a distância do gap e com a amplitude da tensão aplicada. A partir dos resultados obtidos foi possível observar que a intensidade do som das DPs, capturado com o transdutor piezoelétrico, está relacionada com o tamanho do gap e da amplitude da tensão, como relatado na literatura. / Electrical equipment installed in power transmission and distribution lines are usually subjected to abnormal conditions and intense electric fields, which eventually lead, among others phenomena, to partial discharges (PDs). These discharges have been pointed as one of the main causes of equipment failures and premature aging. Therefore, detect PDs became an important issue in the prospect of efficient and reliable electric energy. Concerning PD detection there are several sensors that can be employed e.g. optical, magnetic or acoustic, and each of them presenting particular advantages and limitations. One of the drawback of such sensors is their elevated cost, which restricts the PD monitoring within the distribution of energy more specifically in power transformers. Although, if the intention of monitoring is only to detect the PD occurrence a new class of acoustic sensors implemented with piezoelectrets may be a feasible economic alternative. Therefore, in this work was investigated the acoustic behavior of such transducers exposed to different PD conditions, for instance, the piezoelectret sensor was employed on the detection of PD produced by a single or multiple point-to-point electrode setup with different air gaps excited by high AC voltages. The recorded signals amplitudes were correlated with the gap distance and voltage amplitude applied. Based on the results obtained it was observed that the intensity of the DPs sound, captured with the piezoelectric transducer, is related to the size of the gap and voltage amplitude, as reported in the literature.
9

Sistema inteligente para localização de descargas parciais em transformadores de potência / Intelligent system for location of partial discharge in power transformers

Costa, Paulo Izidio da 27 November 2015 (has links)
O crescente aumento na demanda de energia elétrica nacional, associada às alterações regulamentares do setor, em que o tempo que um equipamento permanece indisponível para o sistema, aguardando manutenção significa perda de receita para as companhias de energia, motivou a busca por diagnósticos precisos e utilização de técnicas não invasivas que possam ser aplicadas em transformadores em serviço. Assim, o foco desta pesquisa foi o desenvolvimento de uma arquitetura de sistema inteligente baseado em Redes Neurais Artificiais, que a partir de características extraídas de sinais de emissão acústicas provenientes de sensores distribuídos espacialmente no tanque de transformadores de potência, possa identificar internamente o local de ocorrência das descargas parciais e fornecer as distâncias estimadas entre os sensores e o ponto dessa descarga, e com essas distâncias, utilizando técnicas numéricas de triangulação, o sistema fornece também a coordenada espacial da falha auxiliando no diagnostico de defeito do transformador e no processo de tomada de decisões. / The increasing in the demand for national electrical energy coupled with alterations in the regulation of the sector, where the time which a piece of the electrical system equipment stays out of service means loss of income for the electrical companies, has motivated the search for correct diagnostics and usage of non-invasive technics that can be used in tranformers which are in operation. Therefore, the aim of this research was to develop the design of an intelligent system based on Artificial Neural Nets, which through the characteristics extracted from the acoustic emission signals coming from the sensors spatially distributed in the power transformer tank can identify internally the place of the occourrence of the partial discharges and provide the estimate distances between the sensors and the discharges point, so with these distances using triangle technical analysis the system will also provide the spatial coordinate of the flaw for diagnosing the problem with the transformer and help the process of decision making.
10

Descargas parciais em barras estatóricas de hidrogeradores: modelagem por guia de onda e análise de um acoplador

KAWAKATSU, Williams Massayuki 23 October 2009 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2013-01-31T22:33:14Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_DescargasParciaisBarras.pdf: 3427699 bytes, checksum: a71966ca427addcbc8a353532f39f9c0 (MD5) / Approved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2013-02-06T15:05:55Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_DescargasParciaisBarras.pdf: 3427699 bytes, checksum: a71966ca427addcbc8a353532f39f9c0 (MD5) / Made available in DSpace on 2013-02-06T15:05:55Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_DescargasParciaisBarras.pdf: 3427699 bytes, checksum: a71966ca427addcbc8a353532f39f9c0 (MD5) Previous issue date: 2009 / Neste trabalho, tem-se como objetivo modelar as barras estatóricas de hidrogeradores por guias de onda multicamadas e estudar a aplicabilidade de um acoplador (sensor) para monitoramento das ocorrências de descargas parciais no interior dessas barras (mais precisamente, na sua camada isolante). Para isso, inicia-se por uma abordagem conceitual do fenômeno de descargas parciais, na qual é mostrada a importância do monitoramento das mesmas para identificar os sintomas de fragilidade dielétrica dos materiais isolantes dessas barras. Posteriormente, realiza-se uma apresentação sobre os métodos de monitoramento das descargas parciais, analisam-se os sinais de pulsos elétricos produzidos por elas e seus parâmetros típicos. Em seguida, estudam-se os modos de propagação de ondas eletromagnéticas produzidas pelas descargas parciais nas barras estatóricas de hidrogeradores, modelando-as por meio de guias de onda multicamadas. Para finalizar, apresenta-se um modelo de acoplador eletromagnético ou sensor, formado por uma linha de microfita, enfocando a sua aplicabilidade no sistema de monitoramento dessas ondas eletromagnéticas.

Page generated in 0.3754 seconds