• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudos voltametricos de eletrodos quimicamente modificados a base de pasta de carbono e silica gel funicionalizada para determinação de cobre e prata

Ferreira, Keila Schutzer Mendes 25 July 2018 (has links)
Orientador: Luiz Manoel Aleixo / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-25T23:49:56Z (GMT). No. of bitstreams: 1 Ferreira_KeilaSchutzerMendes_D.pdf: 1507384 bytes, checksum: 9edb54e09b29802661d84e7315e8b1bc (MD5) Previous issue date: 1998 / Doutorado
2

Estudo de liberação das fases minerais em minérios de ferro.

Ferreira, Rodrigo Fina January 2013 (has links)
Programa de Pós-Graduação em Engenharia Mineral. Departamento de Engenharia de Minas, Escola de Minas, Universidade Federal de Ouro Preto. / Submitted by Maurílio Figueiredo (maurilioafigueiredo@yahoo.com.br) on 2014-08-06T18:19:01Z No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) DISSERTAÇÂO_EstudoLiberaçãoFases.pdf: 15254406 bytes, checksum: 4ebb7ded22f16eb517bd836d227a21d9 (MD5) / Approved for entry into archive by Gracilene Carvalho (gracilene@sisbin.ufop.br) on 2014-08-07T19:12:57Z (GMT) No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) DISSERTAÇÂO_EstudoLiberaçãoFases.pdf: 15254406 bytes, checksum: 4ebb7ded22f16eb517bd836d227a21d9 (MD5) / Made available in DSpace on 2014-08-07T19:12:57Z (GMT). No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) DISSERTAÇÂO_EstudoLiberaçãoFases.pdf: 15254406 bytes, checksum: 4ebb7ded22f16eb517bd836d227a21d9 (MD5) Previous issue date: 2013 / O presente trabalho teve por objetivo estudar a liberação das fases minerais em duas amostras de itabirito do Quadrilátero Ferrífero/MG, itabiritos friável (IF) e compacto (IC), e avaliar a possibilidade de definição de uma rotina de análises que permita estimar as tendências com relação à liberação mineral. Para tanto as amostras foram fragmentadas em diversos tamanhos (britagem em 1,0 mm e moagem com P95 em 0,210 mm, 0,150 mm, 0,105 mm, 0,075 mm e 0,045 mm), sendo determinados o espectro de liberação e o grau de liberação do quartzo para cada produto de cominuição. As análises foram efetuadas através de dois métodos: microscopia ótica de luz refletida (MOLR) e QEMSCAN®. Realizaram-se também ensaios de flotação em bancada para confirmação das estimativas realizadas com base no estudo mineralógico. Os resultados evidenciaram diferenças significativas entre os itabiritos no âmbito da liberação. O IF apresenta características que facilitam a liberação, como elevada porosidade e maior tamanho dos cristais, o que implica na tendência de individualização satisfatória das fases minerais em malhas granulométricas mais grossas. O IC apresenta textura e associações minerais mais complexas, com baixa porosidade e ocorrência de cristais menores, sendo necessário aplicar moagem em malhas mais finas para obter liberação satisfatória. Os espectros de liberação mostraram que a moagem com P95 em 0,210 mm para o IF, e com P95 em 0,045 mm para o IC deve resultar em liberação satisfatória para posterior concentração. Os ensaios de flotação em bancada confirmaram as malhas de moagem definidas, tendo-se obtido concentrados com qualidade adequada a partir dos minérios moídos nos tamanhos supracitados. Verificou-se que o grau de liberação do quartzo por fração granulométrica do produto britado a 1,0 mm apresenta boa correlação exponencial com o top size de cada fração granulométrica. O parâmetro numérico K da equação de regressão pode ser utilizado como parâmetro representativo das tendências do minério com relação à liberação das fases minerais. As constatações do estudo conduziram à proposta de uma rotina para estudos de liberação em itabiritos, a qual permite a definição da malha de moagem ideal para um grande número de amostras a partir de agrupamentos das mesmas, tendo como critério de agrupamento o parâmetro numérico K anteriormente citado. O QEMSCAN® mostrou-se uma excelente ferramenta para estudos de liberação mineral, fornecendo uma gama considerável de informações úteis. No comparativo entre QEMSCAN® e MOLR verificou-se diferença significativa nos resultados das medições de grau de liberação, sendo que a microscopia ótica tende a superestimar o parâmetro, devido principalmente ao viés estereológico, corrigido no QEMSCAN®. Assim sendo, as malhas de liberação definidas através dos resultados do MOLR seriam mais grossas quando comparadas às malhas definidas por meio de análises no QEMSCAN®. __________________________________________________________________________________________ / ABSTRACT: This research work aimed to study the mineral liberation in two itabirite samples from Ferriferous Quadrangle (Minas Gerais), friable itabirite (FI) and compact itabirite (CI), and evaluate the possibility of defining an analysis routine that allows estimating mineral liberation trends. The samples have been comminuted in several sizes (crushed in 1.0 mm and ground in 0.210 mm, 0.150 mm, 0.105 mm, 0.075 mm and 0.045 mm), and the quartz liberation spectrum have been measured for each comminution product. The samples have been analyzed by two methods: reflected light optical microscopy and QEMSCAN®. Laboratory flotation tests have been carried out to confirm the mineralogical study. The results showed significant differences between the two types of itabirite regarding mineral liberation. The FI sample presents features which facilitates liberation, as high porosity and larger crystals. The CI sample features complex texture and mineral assemblages with low porosity and fine crystals. The mineral liberation spectrums have showed that grinding at 0.210 mm for FI sample, and 0.045 mm for the CI sample should result in satisfactory liberation between the mineral phases for further concentration. The flotation tests have confirmed the grinding sizes defined by the mineralogical study, yielding adequate quality concentrates from the ore samples ground in the sizes given above. It was found that the degree of liberation by size fraction of the 1.0 mm crushed sample has a good exponential correlation with the top size of each size fraction. The numerical parameter K of the regression equation may be used as representative parameter for mineral liberation trends. The findings from this study led to the proposal of a routine for mineral liberation studies on itabirites, which lets the grinding size determination for a large number of samples, by the clustering of the samples according to the numerical parameter K aforementioned. QEMSCAN® has proved to be an excellent tool for mineral liberation studies, providing a considerable range of useful information. Comparing QEMSCAN and optical microscopy degree of liberation measurements, one has found significant differences between the results. The optical microscopy trends to overestimate the parameter, mainly due to the stereological bias.
3

Determinação de cádmio e cromo em amostras lipídicas por espectrometria de obsorção atômica de alta resolução com fonte contínua e atomização em forno de grafite

Silva, Mauana Schneider da January 2016 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas, Programa de Pós-Graduação em Química, 2016 / Made available in DSpace on 2016-09-20T04:51:51Z (GMT). No. of bitstreams: 1 340438.pdf: 853567 bytes, checksum: 3d9bac67d304ff6231a4b50fb4febf7a (MD5) Previous issue date: 2016 / O presente trabalho trata sobre um método simples para a determinação de cádmio e cromo em amostras de óleo de peixe por espectrometria de absorção atômica de alta resolução e fonte continua em forno de grafite. As amostras foram preparadas pela diluição em 1-propanol. Foram utilizados tubos de grafite recobertos de platina e adição de paládio como modificador químico para a determinação de cádmio enquanto para a determinação de cromo não foi utilizado modificador químico permanente ou em solução. A exatidão do método foi avaliada pela comparação entre os resultados obtidos por digestão assistida em micro-ondas, apresentando resultados concordantes com este método alternativo de preparo de amostra. Além de amostras de óleo de peixe, foram quantificadas as concentrações de cádmio e cromo em outras matrizes lipídicas como manteiga de leite e manteiga de cacau. Para cádmio, os limites de detecção e quantificação foram de 0,5 pg e 1,5 pg, respectivamente, a faixa de trabalho foi de 1,5 a 330 pg de cádmio com um coeficiente linear de 0,998. Para cromo, os limites de detecção e quantificação para o método proposto foram de 7 pg e 23 pg, respectivamente; a faixa linear foi de 23 a 1080 pg de cromo, com um coeficiente linear de 0,999.<br> / Abstract: This work presents a simple method to determine cadmium and chromium in fish oil samples in graphite furnace by high-resolution continuum source atomic absorption spectrometry. The samples were prepared by dilution with 1-propanol. For cadmium determination a platinum coated graphite tube and palladium as chemical modifier were used. For chromium determination, no chemical permanent modifier or in solution was employed. The method was evaluated by the comparison with microwave-assisted digested samples, showing a good agreement with this alternative sample preparation. In addition, the concentrations of cadmium and chromium in butter and cocoa butter were measured. For cadmium, the limits of detection and quantification for the developed method were 0.5 pg and 1.5 pg respectively, the working range was 1.5 to 330 pg cadmium with a linear coefficient of 0.998. For chromium, the limits of detection and quantification for the developed method were 7 pg and 23 pg respectively, the working range was 23 to 1080 pg chromium with a linear coefficient of 0.999.
4

Estudos potenciometricos das interações do cobre (II) com ligantes de ocorrencia natural

Gimenez, Sonia Maria Nobre 14 July 2018 (has links)
Orientador : Wilson de Figuiiredo Jardim / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-14T17:49:53Z (GMT). No. of bitstreams: 1 Gimenez_SoniaMariaNobre_M.pdf: 2866211 bytes, checksum: a095abcde6bfe6337b55fb36b9731e29 (MD5) Previous issue date: 1986 / Mestrado

Page generated in 0.0823 seconds