• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Modelos para planejamento de redes convergentes considerando a integração de aspectos de infraestrutura e de negócios

GUIMARÃES, Almir Pereira 09 December 2013 (has links)
Submitted by João Arthur Martins (joao.arthur@ufpe.br) on 2015-03-12T18:23:58Z No. of bitstreams: 2 Tese Almir Guimaraes.pdf: 2829320 bytes, checksum: eb091480cddf819a75f703273675417b (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-12T18:23:58Z (GMT). No. of bitstreams: 2 Tese Almir Guimaraes.pdf: 2829320 bytes, checksum: eb091480cddf819a75f703273675417b (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2013-12-09 / Nos dias atuais, as redes convergentes têm se tornado uma ferramenta essencial para os indivíduos, empresas e governos e têm mudado significativamente a maneira como eles se relacionam. Além disso, estas redes proporcionam o meio de transporte para uma grande variedade de serviços e desta forma, desempenham uma importância considerável para as atividades diárias dos indivíduos e para as receitas das empresas. Questões relativas à prevenção e tratamento de falhas, bem como a garantia de desempenho satisfatório, são assim, de fundamental importância para a permanência nos negócios por parte das empresas. Desta maneira, o projeto da infraestrutura de redes convergentes deve considerar também os aspectos de negócios. A utilização de modelos formais vem sendo constantemente aplicada em diferentes abordagens para a descrição de sistemas computacionais. Este trabalho propõe conjuntamente modelos, métricas e uma metodologia para proporcionar suporte tanto para a escolha do melhor projeto com relação a uma infraestrutura em particular, quanto para uma análise comparativa e objetiva entre diferentes soluções, considerando-se formalmente aspectos de dependabilidade, desempenho e de negócios. Os modelos de infraestrutura consideraram as vantagens de redes de Petri estocásticas e de diagramas de blocos de confiabilidade em uma abordagem hierárquica. Foram ainda definidas métricas para o suporte à escolha do melhor projeto em conformidade com os negócios da empresa, assim como para proporcionar uma análise comparativa e objetiva entre as diferentes soluções de projetos. Por fim, os resultados mostraram a eficácia da aplicação desta metodologia ao reduzir significativamente o número de projetos analisados
2

Assessment to support the planning of sustainable data centers with high availability

CALLOU, Gustavo Rau de Almeida 12 November 2013 (has links)
The advent of services such as cloud computing, social networks and e-commerce has led to an increased demand for computer resources from data centers. Prominent issues for data center designers are sustainability, cost, and dependability, which are significantly affected by the redundant architectures required to support these services. Within this context, models are important tools for designers when attempting to quantify these issues before implementing the final architecture. This thesis proposes a set of models for the integrated quantification of the sustainability impact, cost, and dependability of data center power and cooling infrastructures. This is achieved with the support of an evaluation environment which is composed of ASTRO, Mercury and Optimization tools. The approach taken to perform the system dependability evaluation employs a hybrid modeling strategy which recognizes the advantages of both stochastic Petri nets and reliability block diagrams. Besides that, a model is proposed to verify that the energy flow does not exceed the maximum power capacity that each component can provide (considering electrical devices) or extract (assuming cooling equipment). Additionally, an optimization method is proposed for improving the results obtained by Reliability Block Diagrams, Stochastic Petri nets and Energy Flow models through the automatic selection of the appropriate devices from a list of candidate components. This list corresponds to a set of alternative components that may compose the data center architecture. Several case studies are presented that analyze the environmental impact and dependability metrics as well as the operational energy cost of real-world data center power and cooling architectures. / Submitted by João Arthur Martins (joao.arthur@ufpe.br) on 2015-03-12T18:54:10Z No. of bitstreams: 2 Tese Gustavo Callou.pdf: 4626749 bytes, checksum: 336a34ffc39f6ac623fa1144de2a66bf (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-12T18:54:10Z (GMT). No. of bitstreams: 2 Tese Gustavo Callou.pdf: 4626749 bytes, checksum: 336a34ffc39f6ac623fa1144de2a66bf (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2013-11-12 / O surgimento de servi¸cos como computa¸c˜ao nas nuvens, redes sociais e com´ercio eletrˆonico tem aumentado a demanda por recursos computacionais dos data centers. Preocupa¸c˜oes decorrentes para os projetistas de data center s˜ao sustentabilidade, custo, e dependabilidade, os quais s˜ao significativamente afetados pelas arquiteturas redundantes requeridas para suportar tais servi¸cos. Nesse contexto, modelos s˜ao ferramentas importantes para projetistas quanto a tentativa de quantificar esses problemas antes mesmo de implementar a arquitetura final. Nessa tese, um conjunto de modelos ´e proposto para a quantifica¸c˜ao integrada do impacto na sustentabilidade, custo e dependabilidade das infraestruturas de refrigeramento e potˆencia de data centers. Isso ´e obtido com o suporte do ambiente de avalia¸c˜ao que ´e composto pelas ferramentas ASTRO, Mercury e o m´odulo de otimiza¸c˜ao. A avalia¸c˜ao de dependabilidade faz uso de uma estrat´egia de modelagem h´ıbrida que usa as vantagens tanto das redes de Petri estoc´asticas como dos diagramas de blocos de confiabilidade. Al´em disso, um modelo ´e proposto para realizar a verifica¸c˜ao se fluxo de energia n˜ao excede a capacidade m´axima de potˆencia que cada equipamento pode prover (considerando dispositivos el´etricos) ou extrair (assumindo equipamentos de refrigera¸c˜ao). Adicionalmente, um m´etodo de otimiza¸c˜ao ´e proposto para melhorar os resultados obtidos atrav´es dos diagramas de blocos de confiabilidade, das redes de Petri estoc´asticas e do modelo de fluxo de energia pela sele¸c˜ao autom´atica dos dispositivos apropriados a partir da lista de componentes candidatos. Essa lista corrresponde a um conjunto de componentes que podem ser utilizados para compor a arquitetura de data center. V´arios estudos de casos s˜ao apresentados para analisar o impacto ambiental, a dependabilidade e o custo operacional de energia el´etrica de arquiteturas reais de potˆencia e refrigera¸c˜ao de data centers.
3

PROJETO DE CONTROLADORES PARA CONVERSORES CC-CC PELA ABORDAGEM DO DESACOPLAMENTO DE ESTADOS / DESIGN OF CONTROLLERS FOR DC-DC CONVERTERS FOR APPROACH OF THE DISMANTLING OF

Gomes, Evandro de Carvalho 11 September 2009 (has links)
Made available in DSpace on 2016-08-17T14:53:05Z (GMT). No. of bitstreams: 1 Evandro de Carvalho Gomes.pdf: 6042842 bytes, checksum: 26caa437e6eddbd118b3278d1421a757 (MD5) Previous issue date: 2009-09-11 / In this work, we propose to analyze the controller design of a classical dc-dc converter in a different manner. Instead of the traditional mathematics transfer function analysis, we will describe the block diagram of the plant to be controlled using Space-State Averaging, decoupling the states effects one acts each other and designing the controllers individually. With this technique, we can obtain first order transfer function allowing easier synthesis and design of the involved controllers. Outcomes are compared to controllers based on K-factor approach which are entirely applicable in academy and industry environment. / Neste trabalho propomos analisar o projeto de controladores para conversores cc-cc clássicos de uma forma diferente da tradicional análise matemática da função de transferência, descrevendo o diagrama de blocos da planta a ser controlada, desacoplando os efeitos que um estado exerce sobre o outro e projetando os controladores individualmente. Com essa técnica, obtêm-se funções de transferências de primeira ordem o que permite um projeto e síntese mais fácil dos controladores envolvidos. Os resultados são comparados com os controladores baseados na abordagem do fator K, por se tratar de uma abordagem amplamente aplicada no meio acadêmico e industrial.

Page generated in 0.0601 seconds