• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

PROCEDIMENTO VOLTAMÉTRICO OTIMIZADO PARA DETERMINAÇÃO DE Ni2+ EM AMOSTRAS PRÉ-TRATADAS DE BIODIESEL, USANDO ELETRODO MODIFICADO COM FILME DE MERCÚRIO / PROCEDURE OPTIMIZED VOLTAMMETRIC FOR DETERMINATION OF Ni2 + IN PRE-TREATED SAMPLES OF BIODIESEL, USING MODIFIED ELECTRODE WITH FILM OF MERCURY

Nobre, Eva Michelly Carvalho Santana 04 July 2011 (has links)
Made available in DSpace on 2016-08-19T12:56:36Z (GMT). No. of bitstreams: 1 dissertacao Eva.pdf: 1581206 bytes, checksum: 1aebd130343ea1ba16d040c34b337e22 (MD5) Previous issue date: 2011-07-04 / The presence of metals in biodiesel can be related to raw material, the process used to obtain biodiesel or its storage and can cause reactions of oxidation, corrosion and clogging engines, besides causing risks to human health and the environment. In this paper, we propose a procedure based on voltammetric experimental conditions suitable for the determination of Ni2+ ion in biodiesel (B100) through Square Wave Adsorptive Stripping Voltammetry, using the mercury film electrode prepared ex situ. First, the mercury film was prepared and then was conducted the analysis of a biodiesel pre-treated (digested) sample. The sample digestion was performed with microwave oven in a closed system in the presence of ultra-pure nitric acid and hydrogen peroxide. After this, ammonia buffer 0.01 mol L-1 pH 9.23 and NaOH 0.46 mol L-1 was added into the cell to adjust the pH of the sample to a final value of approximately 9.2. Finally, the chelator dimethylglyoxime (DMG) 0.01 mol L-1 was added, which acts as a complexing element to capture the Ni2+ ion. Next, several voltammetric experiments, in the absence and presence of increasing aliquots of biodiesel and standard solution of the metallic ion, were performed to optimize the analysis conditions. The results indicate that the Square Wave Adsorptive Stripping Voltammetry (VAdRSWV) appeared suitable for measurements of trace metal in Biodiesel (B100) in concentrations up to 10-8 mol L-1. The experiments carried out by successive addition of aliquots of a standard solution of Ni2+ ions provided a linear response of peak current with the concentration of metal ion. Each sample of biodiesel was analyzed in triplicate, with very satisfactory results from the analytical point of view, once we were dealing with trace element analysis, especially in terms of accuracy (recovery 105%) and precision (RSD 9.61%) for the Ni2+ metal ion, using a confidence limit of 98%. / A presença de metais no biodiesel pode estar relacionada com a matéria-prima, com o processo utilizado para a obtenção do biodiesel ou com sua estocagem e pode provocar reações de oxidação, corrosão e entupimento em motores, além de causar riscos à saúde humana e ao meio ambiente. Neste trabalho, é proposto um procedimento voltamétrico com base em condições experimentais adequadas para a determinação do íon Ni2+ em biodiesel (B100) por Voltametria Adsortiva de Redissolução no modo Onda Quadrada, usando o eletrodo de Filme de Mercúrio preparado no modo ex situ. Inicialmente, o filme de mercúrio foi preparado e a seguir realizaram-se as análises com amostra de biodiesel pré-tratada (digerida). A digestão da amostra foi realizada com forno de micro-ondas em sistema fechado, na presença de ácido nítrico ultra-puro e peróxido de hidrogênio. Após essa etapa, foi adicionado tampão amônia 0,01 mol L-1 pH 9,23 e NaOH 0,46 mol L-1 na célula para ajustar o pH da amostra para um valor final de aproximadamente 9,2. Por fim, foi adicionado o quelante dimetilglioxima (DMG) 0,01mol L-1 que funciona como complexante para captura do íon Ni2+. Após esta etapa, vários experimentos voltamétricos, na ausência e presença de alíquotas crescentes de biodiesel e solução padrão do íon metálico foram realizados para otimizar as condições de análise. Os resultados obtidos indicam que a Voltametria Adsortiva de Redissolução no modo Onda Quadrada (VAdRSWV) apresentou resultado satisfatório para medidas do metal traço em Biodiesel (B100), em concentrações de até 10-8 mol L-1. Os experimentos realizados pela adição sucessiva de alíquotas de uma solução padrão do íon Ni2+ proporcionaram uma resposta linear da corrente de pico com a concentração do íon metálico. Cada amostra de biodiesel foi analisada em triplicata, apresentando resultados bastante satisfatórios do ponto de vista analítico por se tratar de análise de elementos traços, principalmente, em termos de exatidão (recuperação de 105 %) e precisão (DPR de 9,61%), para o íon metálico Ni2+, utilizando um limite de confiança de 98%.
2

Determinação de Cu e Fe em Biodiesel por Espectrometria de Absorção Atômica com Atomização Eletrotérmica e Estudo do Efeito Catalítico destes Metais sobre a Estabilidade Oxidativa do Biodiesel / Determination of Cu and Fe in Biodiesel by Absorption Spectrometry Electrothermal atomic and Study of the Effect of Catalytic Metals on the Oxidative Stability of Biodiesel

Ghisi, Mirela 16 May 2011 (has links)
Made available in DSpace on 2016-08-19T12:56:36Z (GMT). No. of bitstreams: 1 MIRELA GHISI.pdf: 1324849 bytes, checksum: 5d9ca5c5a49c366f3bf4959e2e942a14 (MD5) Previous issue date: 2011-05-16 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / The metals content in biodiesel is directly related with the raw material used and also with the utilized biodiesel production method. In this work, an evaluation of the main metals present in biodiesel samples from different sources was done. The qualitative analysis of the metal content was assessed using the Inductively Coupled Plasma Mass Spectrometry technique after sample digestion in microwave oven. The main metals identified in the analyzed biodiesel samples were Al, Cr, Cu, Fe, Mg, Mn, Ni, Pb, Sr and Zn. Metals like Ag, As, Ba, Cd, Co, Tl and V have not significant presence in the samples. Among these, Cu and Fe were selected due to their relevance and importance in oxidative process of biodiesel, to the development of an analytical methodology to be used in the determination by Electrothermal Atomic Absorption Spectrometry, and also evaluate the effect of these metals over the oxidative stability of the soy biodiesel. The samples were prepared with tetramethylammonium hydroxide (TMAH), and the pyrolysis and atomization temperatures were optimized pyrolysis and atomization curves. The high pyrolysis temperature adopted, 1000 oC, certainly minimized potential interferences, but calibration had to be carried out with aqueous standard solutions in the presence of the TMAH. The detection limits in the sample (3s, n=10), were quite low 15 ng g-1 and 24 ng g-1 for Cu and Fe, respectively. Seven biodiesel samples, produced from different raw materials, including vegetable seed, waste frying oil and animal fat were analyzed. Accuracy was validated by applying the recovery test (recoveries from 105% to 120%) and through comparison with the obtained results by High Resolution Continuum Source Electrothermal Atomic Absorption Spectrometry. The precision, expressed by the relative standard deviation, was better than 3% for Cu and than 7% for Fe. Copper could be quantified in two and Fe in three of the seven samples. The biodiesel sample from fodder turnip was especially rich in the analytes in comparison to the other samples. The influence of metals Cu and Fe on soy biodiesel oxidative stability was evaluated by Rancimat method through induction period, according with the Standard EN 14112. The metals Cu2+ and Fe3+ were added to the biodiesel samples in the form of theirs salts, and different storage times of the samples were evaluated. Due to the catalytic behaviour of these metals, the oxidative stability of the samples was affected, even under low metal concentrations. Compared to Cu2+, the effect over the biodiesel stability was higher when Fe3+ was added. / A presença de metais no biodiesel está diretamente relacionada com a matéria-prima utilizada e também com o processo utilizado para a obtenção do biodiesel. Neste trabalho realizou-se uma avaliação dos principais metais presentes em amostras de biodiesel provenientes de diferentes fontes. A análise semi-quantitativa nas amostras de biodiesel foi realizada utilizando a técnica de Espectrometria de Massa com Plasma Indutivamente Acoplado após a digestão das amostras em micro-ondas. Os principais metais identificados nas amostras de biodiesel analisadas são Al, Cr, Cu, Fe, Mg, Mn, Ni, Pb, Sr e Zn. Metais como Ag, As, Ba, Cd, Co, Tl e V não estão presentes em concentrações significativas nessas amostras. Em função de sua relevância e importância em processos oxidativos do biodiesel, selecionou-se Cu e Fe para o desenvolvimento de uma metodologia analítica para a determinação destes por Espectrometria de Absorção Atômica com Atomização Eletrotérmica e também a avaliação do efeito destes metais sobre a estabilidade oxidativa do biodiesel de soja. As amostras foram preparadas com hidróxido de tetrametilamônio (TMAH), e as temperaturas de pirólise e atomização foram otimizadas através de curvas de pirólise e atomização. A alta temperatura de pirólise adotada, 1000 oC, certamente ajudou a minimizar possíveis interferências; porém, a calibração teve de ser realizada com padrões aquosos na presença de TMAH. Os limites de detecção (3s, n = 10), na amostra, foram baixos, 15 ng g-1 e 24 ng g-1 para Cu e Fe, respectivamente. Sete amostras de biodiesel, produzidas de diferentes matérias-primas, incluindo óleos vegetais, óleo de fritura e gordura animal foram analisadas. A exatidão foi avaliada através do teste de recuperação (recuperações de 105% a 120%) e através da comparação com os resultados obtidos por Espectrometria de Absorção Atômica de Alta Resolução com Fonte Contínua e Atomização Eletrotérmica. A precisão, expressa pelo desvio padrão relativo foi melhor que 3% para Cu e que 7% para Fe. Cobre pôde ser quantificado em duas e Fe em três das sete amostras. A amostra de biodiesel proveniente do nabo forrageiro era especialmente rica nos analitos comparada às outras amostras. A influência dos metais Cu e Fe sobre a estabilidade oxidativa do biodiesel de soja foi avaliada pelo método Rancimat através do período de indução, de acordo com a Norma EN 14112. Os metais Cu2+ e Fe3+ foram adicionados nas amostras de biodiesel na forma de seus sais, e foram avaliados diferentes tempos de armazenamento das amostras. Devido ao efeito catalítico destes metais, a estabilidade oxidativa das amostras analisadas foi reduzida mesmo na presença de baixas concentrações dos metais. O efeito do Fe3+ sobre a estabilidade do biodiesel foi significativamente maior quando comparado ao Cu2+.

Page generated in 0.0532 seconds