• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 35
  • 13
  • 2
  • 2
  • 1
  • Tagged with
  • 56
  • 56
  • 33
  • 13
  • 9
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Influência de diferentes meios de digitalização de radiografias na avalição de cáries proximais / Comparative performance of indirect digitized radiographs for detecting approximal caries

Claudio Roberto Gaião Xavier 26 October 2007 (has links)
Avaliar a influência no diagnóstico de cáries proximais das imagens geradas por dois escâneres e quatro máquinas fotográficas digitais, em formato JPEG e TIFF, e comparar o desempenho destes equipamentos ao das radiografias convencionais em relação à presença e profundidade de lesões de cárie proximais. 56 dentes extraídos foram radiografados com filme Kodak Insight em um aparelho de raios X Yoshida Kaycor, operando com 70kv e 7mA, com tempo de exposição de 0,40s. As radiografias resultantes foram digitalizadas pelos escaneres CanonScan e Genius ColorPage, e máquinas fotográficas digitais Canon Powershot G2, Canon RebelXT, Nikon Coolpix 8700 e Nikon D70s, nos formatos JPEG e TIFF. As radiografias convencionais e as imagens digitais obtidas foram avaliadas por três examinadores em duas sessões de observação. Classificaram a presença de acordo com uma escala de três níveis e a profundidade de acordo com uma escala de três níveis, quando julgassem que havia lesão. Os dentes foram seccionados no sentido mésiodistal e observados ao microscópio em luz polarizada com aumento de 10x, para a verificação da presença e profundidade da lesão de cárie. Foram determinados concordância intra e interexaminadores, probabilidade de não diagnóstico, sensibilidade, especificidade e acurácia para cada equipamento, em ambos os formatos, e para as radiografias convencionais. Os resultados foram submetidos à análise de variância a dois critérios, demonstrando que não houve diferenças estatisticamente significantes entre os formatos. A concordância intraexaminadores foi de moderada a satisfatória, e a interexaminadores de regular a moderada. A probabilidade de não diagnóstico variou de 1,34% (Convencional) a 52,83% (Escaner CanonScan/JPEG). A sensibilidade variou de 0,24 (Canon RebelXT/JPEG) a 0,53 (Convencional), a especificidade de 0,93 (Nikon Coolpix/JPEG; Canon Powershot/TIFF; Cânon RebelXT/JPEG e TIFF) a 0,97 (Escaner CanonScan/TIFF e JPEG), e a acurácia variou de 0,82 (Canon RebelXT/JPEG) a 0,91 (Escaner CanonScan/JPEG). O teste de proporções indicou diferenças estatisticamente significantes para o Escaner CanonScan, para ambos os formatos, quando comparado aos demais equipamentos e à radiografia convencional. Foi possível concluir que os formatos não influenciaram o desempenho no diagnóstico de cárie para qualquer equipamento usado. O Escaner CanonScan apresentou o pior desempenho e não se mostrou adequado para digitalização de radiografias para o diagnóstico de lesões de cárie. / To evaluate the performance of conventional and indirect digital radiography and the effect of JPEG and TIFF file formats for detecting proximal surface caries. Fifty-six extracted teeth were mounted in blocks and radiographed with Insight conventional film. Films were digitized by two flatbed scanners (Canon CanonScan and Genius ColorScan) and four digital cameras (Canon Powershot G2, Canon Rebel XT, Nikon Coolpix 8700 and Nikon D70), in both JPEG and TIFF file formats. Three observers recorded the presence and depth of caries on 112 proximal surfaces for the conventional and digitized radiographs. They scored lesion presence in a 3-point confidence scale and depth on another 3-point scale. Radiographs were evaluated twice. The observer\'s scores were compared with the results from a histological examination. Intra-observer agreement was moderate to good and interobserver agreement was fair to moderate. Sensitivities varied from 0.24 (Canon RebelXT/JPEG) to 0.53 (Convencional) and specificities from 0.93 (Nikon Coolpix/JPEG; Canon Powershot/TIFF; Canon RebelXT/JPEG e TIFF) to 0.97 (Escaner CanonScan/TIFF e JPEG). The accuracy varied from 0.82 (Canon RebelXT/JPEG) to 0.91 (Escaner CanonScan/JPEG). Images from CanonScan, both JPEG and TIFF, showed significant statistically differences compared with digital radiographs from the others devices and conventional film radiographs. File formats did not influences the detection of proximal caries. Digitizing conventional radiographs using the scanner CanonScan did not produce images of diagnostic quality.
22

Avaliação radiográfica da movimentação do segundo molar inferior após a exodontia do terceiro molar

Gabriel Fiorelli Bernini 25 March 2009 (has links)
Muitos pacientes submetidos à exodontia de terceiros molares relatam, no pósoperatório, que percebem alterações na oclusão. Por isso é interessante avaliar se realmente existe esta possível movimentação para distal dos segundos molares inferiores após a exodontia dos terceiros molares. Os objetivos deste trabalho foram analisar e verificar se existe variação da angulação do longo eixo do segundo molar em relação ao longo eixo do primeiro molar por meio de tomadas radiográficas periapicais digitais pelo sistema Digora®. A amostra constituiu-se de 20 pacientes entre 15 e 25 anos de idade que possuíam terceiros molares inferiores não irrompidos, bilateralmente, com indicação para extração e que se apresentavam de maneira simétrica com relação ao seu posicionamento. Os dentes foram extraídos, sendo um dos lados mantido apenas o coágulo (grupo controle) e o outro lado (grupo experimental) recebeu o enxerto do material proposto e membrana de cortical óssea bovina desmineralizada (Gen-derm). No Adobe Photoshop 7.0 foi possível realizar os traçados dos longos eixos dos primeiros e segundos molares inferiores e a intersecção entre eles. O programa ImageJ 1.41 foi responsável pela obtenção dos valores das angulações. Os exames foram realizados utilizando medidas em imagens obtidas no controle pós-operatório imediato, de 2, 6 e 24 meses nos dois grupos estudados. Os resultados mostraram que não houve diferença estatisticamente significante entre os grupos experimental e controle, e também não houve diferença ao longo do tempo, sugerindo que não existe movimentação para distal dos segundos molares inferiores após a extração dos terceiros molares e alterações na oclusão. Unitermos: Terceiro molar, Radiografia digital, Movimentação dentária. / Many patients submitted to the extraction of third molars, report, postoperatively, that they feel alterations in their occlusion. Thus, it is interesting to assess whether this possible movement to the distal of lower second molars, following the removal of third molars, really exists. This work aimed at analyzing and verifying, through digital periapical radiographies of the Digora® System, whether the angulation of the second molar´s long axis varies in relation to that of the first molar. The sample was comprised of 20 patients between 15 and 25 yrs, who presented non-erupted lower third molars, bilaterally, referred to extraction and in a symmetrical manner, in relation to their position. The teeth were extracted, being maintained, in one of the sides, only the clot (control group), while the other side (experimental group) received the graft of the proposed material and demineralized cortical bone bovine membrane (Gen-derm). In the Adobe Photoshop 7.0, it was possible to perform the outlining of the long axes of lower first and second molars and the intersection between them. The 1.41 ImageJ Program allowed the angulations values, and the exams were performed by utilizing measures in images obtained in the immediate postoperative control of 2, 6 and 24 months, in the groups studied. No statistically significant difference was seen between the experimental and control groups, as there was no difference as time passed, suggesting that there is no movement towards the distal of lower second molars, following the extraction of third molars and alterations in the occlusion.
23

"Validação das ferramentas de calibragem de medidas em três sistemas de radiografia digital" / Assessment of calibration tools of three digital radiography systems

José Raul Girondi 30 March 2006 (has links)
O desenvolvimento tecnológico busca fatores que possibilitem uma menor exposição do paciente e profissional aos raios ionizantes, maior agilidade no atendimento ao paciente e maior auxilio no desenvolvimento do diagnóstico final. Assim a associação entre informática e radiologia básica, traduzidas como radiologia digital, fez-se conseguir os fatores buscados. Uma ferramenta dos sistema digitais é a calibração prévia às medidas. Com essas observações avaliamos tais ferramentas de três sistemas de radiografias digitais, objetivando validar e comprovar sua eficácia nas metodologias dos trabalhos presentes e futuros. Para tanto utilizamos 20 dentes humanos secos provindos do Banco de Dentes Permanentes da FOUSP, os quais foram radiografados com o auxílio de três sistemas de radiografia digital, direto e semidireto (Digora, RVG Trophy e Visualix). O padrão ouro das medidas dos dentes foi a verificação das dimensões dos dentes por meio de um paquímetro digital e posteriormente comparados os seus padrões de medidas com os softwares dos respectivos sistema. Os resultados foram analisados estatisticamente pelo ANOVA (métodos de Tukey e Dunnett), chegando às seguintes conclusões: existe diferença significante entre os aparelhos p<0,001; a média das medidas obtidas houve diferença significante (p<0,001) com o aparelho Digora foi menor que as médias obtidas com os aparelhos das marcas Visualix e RVG; considerando-se o padrão A e o padrão B de calibragem, não existe diferença estatística significante entre os avaliadores; considerando-se a calibragem sem padrão, um dos avaliadores obteve média mais elevada que os demais avaliadores no caso das medidas realizadas com o aparelho Digora, porém este fato não se repetiu quando da utilização dos outros aparelhos; comparando-se as medidas de referência (paquímetro) observa-se que mais uma vez o aparelho Digora (padrão A, padrão B e sem padrão) apresentou diferença significativa; os aparelhos das marcas Visualix e RVG não mostraram diferenças significativas quando comparados com o valor de referência. / Technological development aims at reducing exposure of both the professional and the patient to ionizing radiation, improving patient treatment and aiding final diagnosis. The combination of computer technology and radiology, i.e. digital radiography, has made this possible. One of the tools of digital radiography systems is calibration prior to measurement. The purpose of this study was to assess the calibration tools of three digital radiography systems to verify their efficacy. Twenty human teeth obtained from the Human Teeth Bank of the School of Dentistry, University of São Paulo, were used. The dry teeth were radiographed using three different direct digital radiography systems Digora, RVG Trophy and Visualix. The measurements of the teeth obtained with a digital caliper were considered the gold standard. These measurements were later compared with those obtained using the digital systems. The results were submitted to ANOVA (methods of Tukey and Dunnett), and the following conclusions were drawn: there was a significant difference between the systems used (p < 0.001); the averages of the measurements obtained with the three systems were significantly different (p<0,001). Visualix and RVG were more accurate than Digora considering A and B calibration standards, no significant difference was observed between the examiners; when there was no calibration standard and the Digora system was used, one examiner obtained more high averages measurements than the others; when there was no calibration standard and Visualix or RVG systems were used, no differences were observed between the examiners; the measurements obtained with Digora system (standards A, B or no standard) were statistically different from the gold standard the measurements obtained with Visualix and RVG systems presented no significant difference when compared with the gold standard.
24

Influência dos meios de apresentação da imagem digital no diagnóstico e tratamento da cárie proximal realizado por alunos da graduação em Odontologia / Influence of the media presentation of digital imaging in the diagnosis and treatment of proximal caries performed by undergraduate students

Barbosa, Vera Lúcia Sales de Araújo 05 June 2011 (has links)
Made available in DSpace on 2015-09-25T12:18:22Z (GMT). No. of bitstreams: 1 Vera Lucia Sales de Araujo Barbosa.pdf: 906152 bytes, checksum: 9d151c05eda7ec83b62804ab3fd0e88c (MD5) Previous issue date: 2011-06-05 / The aim of this study was to assess the influence of the different digital radiographic display means on proximal caries detection and the consequent treatment decision chosen by undergraduates. 40 digital images of human extracted teeth were obtained. The proximal surfaces of those teeth were evaluated for the presence of proximal caries by 36 dentistry undergraduates, divided in three groups base on their degree of knowledge. For each surface, the chosen therapeutic treatment should also be indicated. The evaluations were done on a laptop and on printed digital images using a negatoscope. The accuracy of the display means for incipient caries detection was evaluated by the means of the areas under ROC curve (Az) and its effect by mixed linear regression. For the chosen therapeutic treatment sediment analyses was done to verify its adequacy to the diagnosis. There was no significant effect neither for the display modality (p=0.058), nor to the student groups (p=0.991). The mean area under the ROC curve for the printed images was 0.539 and 0.516 digital images. Treatment decision was consistent with the chosen diagnosis. The accuracy of proximal caries detection on digital images viewed in a laptop was comparable to printed images. The therapeutic decision was not affected by the digital radiographic image display modalities. The undergraduate progression on dentistry program does not enhance their precision to detect proximal caries. / O objetivo do presente estudo foi investigar a influência do meio de apresentação da imagem radiográfica digital no diagnóstico da cárie proximal e na decisão de tratamento dele decorrente, realizado por alunos de graduação. Foram obtidas 40 imagens digitais de dentes humanos extraídos. As superfícies proximais dos dentes foram avaliadas quanto à presença de cárie proximal por 36 estudantes de odontologia, distribuídos em três grupos de acordo com o nível de formação. Para cada superfície foi também indicada a terapêutica considerada mais adequada. As avaliações foram efetuadas em um laptop e em imagens impressas com o auxílio do negatoscópio. A acurácia dos meios de apresentação quanto à detecção de cárie incipiente foi avaliada pela média das áreas sob as curvas ROC e seu efeito por uma análise de regressão linear mista. Para a tomada de decisão terapêutica foi realizada uma análise de resíduos para verificar sua adequação ao diagnóstico. Não houve efeito significativo nem para a modalidade de visualização (p=0.058) e nem para os grupos de alunos (p=0.991). A média das áreas sob as curvas Roc para o filme foi de 0.539 e de 0.516 para laptop. A decisão de tratamento foi condizente com o diagnóstico efetuado. A acurácia do diagnóstico da cárie proximal realizado em tela de laptop é comparável ao realizado em negatoscópio. A tomada de decisão terapêutica não foi afetada pelo meio de apresentação da imagem radiográfica digital. A progressão do aluno no curso não melhora a precisão diagnóstica da cárie proximal.
25

Avaliação de tres metodos radiograficos - periapical, panoramico e sistema digital - no diagnostico de lesões apicais produzidas artificialmente

Santos, Julio Cesar Bento dos 06 February 1999 (has links)
Orientador: Solange Maria Almeida / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T12:46:37Z (GMT). No. of bitstreams: 1 Santos_JulioCesarBentodos_M.pdf: 7612034 bytes, checksum: 606a68f5cabb358d723b7501b7c58c5b (MD5) Previous issue date: 1999 / Resumo: O presente estudo teve por finalidade avaliar três métodos radiográficos, radiografia periapical, radiografia panorâmica e sistema digital, no diagnóstico de lesões apicais produzidas artificialmente em mandíbulas maceradas. E se o tamanho das lesões interferem no diagnóstico radiográfico. Para tanto, as lesões apicais foram produzidas utilizando-se brocas esféricas com diâmetros diferentes, permitindo assim que o diâmetro das lesões sofresse alteração em tamanho conforme a broca utilizada. Assim, o estudo foi dividido em 04 fases: fase inicial ou 1, caracterizada pela ausência de lesão; fase 2, caracterizada pela lesão produzida com a broca 6 com medida da ponta ativa de 1,8mm; fase 3, caracterizada pela lesão produzida com a broca 8 com medida da ponta ativa de 2,3mm; fase 4, caracterizada pela lesão produzida com a broca 10 com medida da ponta ativa de 2,7mm; e fase cortical ou 5, quando a lesão atingia as corticais ósseas. Todas as fases foram, realizadas em 04 regiões da mandíbula: incisivo, canino, pré-molares e molares. As radiografias foram obtidas após cada fase e, posteriormente, foram analisadas por 04 radiologistas. Houve diferença estatisticamente significante na fase broca 6 (R) nos incisivos a favor do sistema digital. O mesmo ocorreu na fase cortical (LI) na região de pré-molares. Na região dos molares houve uma diferença etatisticamente significante na fase broca 10 (D) para a radiografia panorâmica e na fase cortical esta técnica foi a menos eficaz. Nas demais fases e regiões não houve uma diferença estatisticamente significante / Abstract: The aim of this study was to evaluate three radiographys techniques: periapical radiography, panoramic and digital radiography, about diagnostic accuracy of artificially produced bony lesions in human jaw dry. The periapical diseases were done using burs numbers 6, 8 and 10 thus allowing the lesions diameter to incresing according to burs size. Therefore, the study was dividided in four phases: phase 1 without periapical disease, phase 2 periapical disease made by bur number 6, phase 3 periapical disease made by bur number 8, phase 4 periapical disease made by bur number 10 and phase 5 periapical disease touchs junction area of the cortex. The phases were in four regions in the jaw, anterior, canine, premolar and molar. The radiographies were evaluated by four oral radiologists observers. The results showed that in the anterior region there was a significant statistically difference only at phase 2, that is the lesion was produced with bur 6, the digital radiography was more successfull and it was also observed in the premolar region in the cortical phase. In the molar region there was a false true result during the inicial phase, without lesion. During phase 4 (burn 10 ) and cortical phase there was a statistically significant difference in favor of the panoramic radiography / Mestrado / Radiologia / Mestre em Odontologia
26

[en] A SPINE 3D MODELING SYSTEM BASED ON X-RAY IMAGES / [pt] UM SISTEMA DE MODELAGEM 3D DE COLUNA VERTEBRAL BASEADO EM IMAGENS DE RAIOS-X

PEDRO SAMPAIO VIEIRA 13 January 2010 (has links)
[pt] Nos dias atuais, pesquisas envolvendo a computação gráfica e a área médica, têm contribuído muito para a evolução tecnológica de exames e diagnósticos. Uma vertente desses trabalhos está relacionada diretamente à reconstrução 3D de estruturas anatômicas do corpo humano, em específico a coluna vertebral. O sedentarismo e a alta dependência dos computadores vêm aumentando e agravando os problemas posturais das pessoas. Por esse motivo, novas técnicas de reconstrução 3D baseada em exames de tomografia computadorizada (TC), ressonância magnética (RM) e raios-x são desenvolvidas, tornando as avaliações clínicas cada vez mais precisas. Neste trabalho é proposto um sistema de modelagem 3D baseado em radiografias digitais com a finalidade de recriar a coluna vertebral em um ambiente virtual. A recuperação das informações tridimensionais de cada vértebra ajuda a melhorar a avaliação feita atualmente com base apenas em imagens 2D. A técnica utilizada no desenvolvimento do método se baseia na estereoradiografia. E a utilização de radiografias, em relação à TC, reduz consideravelmente o tempo de exposição do paciente à radiação, além de ser mais acessível à população pelo seu menor custo. Os resultados obtidos apresentaram uma boa precisão do sistema. Além do mais, o método proposto atingiu resultados bem próximos aos de pesquisas baseadas em TC e RM, onde os dados de entrada são bem mais legíveis do que as imagens de raiosx. / [en] Research involving computer graphics and laboratory exams has contributed much to the quality of the Medical diagnose. One aspect of these researches is directly related to 3D reconstruction of anatomical structures of the human body, especially the spine. The sedentary lifestyle and the high dependence of computers have increased the postural problems of the population. Therefore, new techniques for 3D reconstruction based on Computed tomography (CT), magnetic resonance imaging (MRI) and x-ray images are required, in order to make the clinical evaluation increasingly accurate. This work proposes a 3D modeling system based on x-ray images that yields a virtual spine model. The recovery of three-dimensional information of each vertebra helps improve the assessment currently made using only 2D images. The technique used here is based on stereo radiographic. The use of x-ray images instead of CT, significantly reduces the exposure time of the patient to radiation, and is more useful to the general population due to its lower cost. The results presented here show good accuracy despite its lower cost. The proposed method has achieved results very close to those based on expensive CT or MRI, where the input image is better than x-ray images.
27

Cephalometric regional superimpositions -- digital vs. analog accuracy and precision : 3. the cranial base

Shaw, Douglas 01 January 2014 (has links)
Objective. To assess the accuracy and precision in measurement of pairwise implant displacement across three methods of cranial base superimposition. Background. Cephalometric superimposition is the principal radiographic method used to evaluate changes within the craniofacial skeleton. Many studies have examined the accuracy of software intended to produce cephalometric superimposition. Such studies have utilized anatomic landmarks, selected by the respective software manufacturers, as registration points for constructing superimpositions and their analysis. As a result, these studies are only as accurate as the stability and validity of anatomic registration landmarks used. To our knowledge, no other study has utilized metallic implants to critically assess digital vs. analog cephalometric cranial base superimposition. Methods. Serial cephalograms from twenty-two patients across three time points containing metallic implants were obtained from the Mathews Acquisition Group. Each of the sixty-six cephalograms was traced by hand and digitally. Cranial base superimpositions were completed according to the analog structural method proposed by Björk and Skieller, and Johnston, and then by Dolphin version 11.5 and Quick Ceph Studio V3.2.8 digital software according to manufactures instructions. Total displacement measurements of selected implants across paired time points were recorded for both digital methods and analog method of superimposition with analog serving as the reference. Results: There were no statistically significant contrasts of mean total displacement of implants by superimposition method (p = 0.999). No significant differences are reported in mean implant displacement when comparing digital to analog superimposition methods for contrasts by time, structure, or implant location. Conclusions: The results show that there are no significant differences in accuracy and precision of digital and analog cranial base superimposition. The results of this study suggest that cranial base superimpositions on S-Na that are registered on S may be a good approximation of the structural method of cranial base superimposition. There are many methodological differences between digital and analog cranial base superimposition and future research examining such differences is recommended.
28

Technical Note: Impact on detective quantum efficiency of edge angle determination method by International Electrotechnical Commission methodology for cardiac x-ray image detectors

Gislason-Lee, Amber J., Tunstall, C.M., Kengyelics, S.K., Cowen, A.R., Davies, A.G. 02 July 2015 (has links)
No / Purpose: Cardiac x-ray detectors are used to acquire moving images in real-time for angiography and interventional procedures. Detective quantum efficiency (DQE) is not generally measured on these dynamic detectors; the required “for processing” image data and control of x-ray settings have not been accessible. By 2016, USA hospital physicists will have the ability to measure DQE and will likely utilize the International Electrotechnical Commission (IEC) standard for measuring DQE of dynamic x-ray imaging devices. The current IEC standard requires an image of a tilted tungsten edge test object to obtain modulation transfer function (MTF) for DQE calculation. It specifies the range of edge angles to use; however, it does not specify a preferred method to determine this angle for image analysis. The study aimed to answer the question “will my choice in method impact my results?” Four different established edge angle determination methods were compared to investigate the impact on DQE. Methods: Following the IEC standard, edge and flat field images were acquired on a cardiac flat-panel detector to calculate MTF and noise power spectrum, respectively, to determine DQE. Accuracy of the methods in determining the correct angle was ascertained using a simulated edge image with known angulations. Precision of the methods was ascertained using variability of MTF and DQE, calculated via bootstrapping. Results: Three methods provided near equal angles and the same MTF while the fourth, with an angular difference of 6%, had a MTF lower by 3% at 1.5 mm−1 spatial frequency and 8% at 2.5 mm−1; corresponding DQE differences were 6% at 1.5 mm−1 and 17% at 2.5 mm−1; differences were greater than standard deviations in the measurements. Conclusions: DQE measurements may vary by a significant amount, depending on the method used to determine the edge angle when following the IEC standard methodology for a cardiac x-ray detector. The most accurate and precise methods are recommended for absolute assessments and reproducible measurements, respectively. / Funded by Philips Healthcare, NL, and a University of Leeds Career Development Bursery.
29

Avaliação da reabsorção radicular externa em dentes tratados endodonticamente após tratamento ortodôntico por meio de análise comparativa de métodos radiográficos / Evaluation of the external root resorption in endodontically treated teeth after orthodontic treatment by comparative analysis of radiographic methods

Chavez, Janet Elizabeth Romero La Fuente 23 April 2009 (has links)
Esta pesquisa teve por objetivo avaliar a reabsorção radicular externa em dentes tratados endodonticamente após tratamento ortodôntico, por meio de análise das imagens das radiografias panorâmica final digitalizada, convencional periapical digitalizada e digital direta, como também comparar os métodos radiográficos empregados. Foram selecionados, após uma avaliação de 2.130 documentações ortodônticas 20 dentes de pacientes com documentação ortodôntica completa, boas condições de saúde, faixa etária entre 25 a 50 anos de ambos os sexos e com dentes anteriores (incisivo central ou lateral) tratados endodonticamente antes da realização do tratamento ortodôntico. De cada documentação ortodôntica completa foi selecionada a radiografia panorâmica inicial e final e, posteriormente, foram obtidas duas radiografias periapicais atuais de cada dente, uma pela técnica convencional e outra digital direta. Após a obtenção e identificação das radiografias, as imagens da panorâmica final digitalizada, radiografia periapical convencional digitalizada e digital direta foram analisadas na tela do computador por três especialistas (endodontista, ortodontista e radiologista). Estes avaliaram se a reabsorção radicular externa estava presente ou ausente no dente tratado endodonticamente após tratamento ortodôntico, bem como compararam os métodos empregados verificando sua confiabilidade. Os seguintes parâmetros foram observados: a) lesão periapical, b) espaço pericementário e c) limite do tratamento endodôntico. As observações foram submetidas à análise estatística chegando-se às seguintes conclusões: 1) A maioria dos ortodontistas não utiliza radiografias periapicais para avaliar os dentes tratados endodonticamente antes do tratamento ortodôntico, o que pode comprometer o andamento e o resultado final do tratamento, visto que a reabsorção radicular não apresenta um caráter sintomatológico no seu diagnóstico; 2) Quanto à reabsorção radicular externa, os examinadores apontaram que houve um incremento desta, na maioria do tipo suave e localizada na região apical, e que a radiografia digital direta foi o método radiográfico mais eficiente na determinação deste diagnóstico. / In this research, the assessment of the external root resorption was carried out in endodontically treated teeth after orthodontic treatment, through the analysis of the image of the digital panoramic radiography, the digital periapical conventional and direct digital; as well as the employed methods were comparatively appraised. It was selected, after an evaluation of 2,130 orthodontic records from two centres of orthodontic studies, 20 teeth of patients with complete orthodontic records, good health conditions, age group between 25 and 50 years-old of both sexes and with front teeth (central or lateral incisor) endodontically treated before the accomplishment of the orthodontic treatment. An initial and final panoramic radiography were selected from each orthodontic record, and, later two current radiographies were obtained from each patient, one by conventional technique and the other by direct digital. After the obtaining and identification of the radiographies, the images of the digital panoramic of the digital conventional and of the direct digital were analyzed on the computer screen by three experts (an endodontist, an orthodontist and a radiologist) who evaluated whether the external root resorption was present or absent in the endodontically treated tooth after the orthodontic treatment and comparatively assessed the employed methods, verifying their reliability; they also observed the following parameters: a) periapical lesion, b) pericemental space, and c) limits of the endodontical treatment. The observations were submitted to a statistical analysis, reaching the following conclusions: 1) most of the orthodontists don\'t use periapical radiographies to evaluate endodontically treated teeth. Before the orthodontic treatment, what can compromise its course and its final results, once the root resorption doesn\'t present a symptomatology in its diagnosis; 2) as for the external root resorption, examiners claimed that there was an increment in it, most in the soft type and located in the apical area, and that the evaluation of the effectiveness of the resorption diagnosis, as well as of the other appraised parameters, indicated that the direct digital radiography obtained better outcomes regarding its identification and its classification.
30

Über die Optimierung von Waveletalgorithmen für die verlustbehaftete Kompression digitaler Röntgenbilddaten

Ricke, Jens 29 May 2001 (has links)
Ziel: Eine Optimierung medizinischer Bilddatenkompression. Evaluation des Einflusses unterschiedlicher Filter auf die Bildqualität waveletkomprimierter Röntgenbilder. Material und Methode: Im Rahmen von Vorstudien Optimierung der digitalen Bildbefundung anhand von ROC-Analysen. Auswahl geeigneter Kompressionsverfahren durch methodischen und ROC-gestützten Vergleich von Wavelet- mit fraktaler und JPEG-Kompression. Im Rahmen der Hauptstudie ROC-basierter und statistischer Vergleich von 4 unterschiedlichen Waveletfiltern verschiedener Komplexität mittels Prüfkörper für niedrigfrequente, gemischt-frequente und hochfrequente Bildinformation im schwellenwertnahen Bereich. Ergebnisse: Durch Einsatz unterschiedlicher Filter insbesondere im Niedrigfrequenzbereich entstehen signifikante Unterschiede des Rekonstruktionsergebnisses der Röntgenbilder. Trotz eines partiell uneinheitlichen Ergebnisses der visuellen Analyse fanden sich Vorteile für komplexere Filter. Für Details im hochfrequenten Bereich finden sich kaum signifikante Unterschiede. Schlußfolgerungen: Die durch die ROC-Analyse erhobenen Ergebnisse korrelierten in keiner Weise mit den gleichzeitig mathematisch erhobenen PSNR-Werten. Ursache hierfür ist, daß die Reduktion des Bildrauschens durch die Waveletkompression in der PSNR als negative Einflußgröße abgebildet wird. Bei medizinischen Röntgenbildern führt jedoch die Minimierung des Bildrauschens zu einer erhöhten Erkennbarkeit von Details insbesondere im schwellenwertnahen Bereich. Entsprechend verbesserten sich die Ergebnisse der schwellenwertnah durchgeführten ROC-Analyse ungleichsinnig zu den PSNR-Werten. Eine detaillierte Beschreibung des Einflusses der Komplexität von Waveletfiltern auf die Rekonstruktionsqualität medizinsicher Bilder findet sich im Diskussionsteil der Studie. / Aim: Optimisation of medical image compression. Evaluation of wavelet-filters for wavelet-compression. Materials and methods: Optimisation of image review applying ROC analysis. Analysis of medical image compression methods comparing wavelet-compression, fractal compression and JPEG by ROC analysis. Evaluation of 4 different wavelet-filters with different complexity applying phantoms for low frequency, high and mixed frequency information. Results: Application of filters with different complexity results in significant variations in the quality of image reconstruction after compression specifically in low frequency informatiin. Filters of high complexity proved to be advantagous despite of heterogenous results during visual analysis. For high frequency details, complexity of filters did not prove to be of significant impact on image quality after reconstruction. Conclusions: Results of ROC analysis did not correspond with PSNR values. Reduction of image noise in reconstructed images by wavelet-filtering is expressed negatively in PSNR values. In medical images, reduction of image noise enhances detection specifically of low contrast details. A detailed discussion of the influence of filter complexity on the reconstruction quality of medical images can be found in the discussion section of the study.

Page generated in 0.0753 seconds