• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

AvaliaÃÃo da eficiÃncia antimicrobiana das soluÃÃes sanitizantes usadas na higienizaÃÃo de um entreposto de pescado. / Evaluation of the antimicrobial efficiency of sanitizing solutions used in cleaning of fishery industry.

Artamizia Maria Nogueira Montezuma 28 February 2013 (has links)
Os MÃtodos da DiluiÃÃo de Uso (MDU) e da SuspensÃo da AOAC sÃo oficialmente aceitos no Brasil na avaliaÃÃo da eficiÃncia antimicrobiana de desinfetantes, para fim de registro comercial. O estudo teve como objetivo determinar a eficiÃncia antimicrobiana das soluÃÃes de hipoclorito de sÃdio nas concentraÃÃes 5, 100 e 200mg/L e de cloreto de benzalcÃnio a 77 e 10.000mg/L e avaliar os processos de higienizaÃÃo das mÃos e botas dos manipuladores e das caudas de lagosta, como matÃria-prima, em um Entreposto de Pescado na cidade de Fortaleza-CE. Os testes aplicados aos desinfetantes foram MDU (INCQS/POP No65.3210.007) que utiliza as cepas padrÃo Staphylococcus aureus, Salmonella Choleraesuis e Escherichia coli e SuspensÃo (AOAC 960.09) que testa os desinfetantes contra S. aureus e E.coli. Foi verificada a eficÃcia dos procedimentos de higienizaÃÃo das mÃos e botas dos manipuladores e das caudas de lagostas atravÃs da reduÃÃo decimal (RD) das bactÃrias heterotrÃficas cultivÃveis (BHC), de amostras colhidas durante o processamento. Procedeu-se a contagem bacteriana atravÃs do mÃtodo de Contagem PadrÃo em Placas (CPP) pelas tÃcnicas pour plate (mÃos e botas) e spreadplate (caudas), utilizando-se Ãgar Extrato Glicose Triptona (TGEA), e os resultados foram expressos em UFC/mÃo, UFC/cm2 e UFC/cauda. As soluÃÃes de hipoclorito de sÃdio foram reprovadas pelo MDU nas concentraÃÃes 5, 100 e 200 mg/L e aprovadas (RD > 5 ciclos logarÃtmicos) em pelo menos uma repetiÃÃo para o teste da SuspensÃo. As soluÃÃes do cloreto de benzalcÃnio foram aprovadas nos dois testes apresentando melhor eficiÃncia microbiolÃgica para o teste de suspensÃo (RD >5 ciclos logarÃtmicos) na concentraÃÃo 10.000 mg/L. As RD das mÃos e das botas dos manipuladores e das caudas de lagosta foram respectivamente < 0,8,< 0,6 e < 0,6 ciclo logarÃtmico. O MDU e o MÃtodo da SuspensÃo mostraram concordÃncia parcial na aprovaÃÃo antimicrobiana das soluÃÃes tendo esse Ãltimo maior nÃmero de aprovaÃÃes. A carga microbiana inicial definiu a boa eficiÃncia do processo de higienizaÃÃo para a matÃria-prima e mÃos e a ineficiÃncia para as botas no Entreposto de Pescado. As RD encontradas para as cepas padrÃo (Staphylococcus aureus e Escherichia coli), analisadas pelo mÃtodo da SuspensÃo testando hipoclorito de sÃdio e cloreto de benzalcÃnio foram maiores do que aquelas RD encontradas para BHC apÃs o processo de higienizaÃÃo das mÃos, botas e caudas de lagosta. / The AOAC use-dilution method (UDM) and suspension method are officially accepted in Brazil for the evaluation of the antibacterial efficiency of disinfectants when applying for product registration. The purpose of this study was to determine the antibacterial efficiency of solutions of sodium hypochlorite at 5, 100 and 200mg/L and benzalkonium chloride at 77 and 10,000mg/L, and to evaluate the procedures employed to disinfect raw material (lobster tails) and the hands and boots of handlers at a seafood processing facility in Fortaleza city. The disinfectants were tested with UDM (INCQS/POP No65.3210.007) using standard strains of Staphylococcus aureus, Salmonella Choleraesuis and Escherichia coli, and with the suspension method (AOAC 960.09) using S. aureus and E. coli. The hygienization procedures for hands, boots and raw material were evaluated by decimal reduction (DR) of aerobic mesophiles in samples collected during processing. The bacteria were quantified by standard plate count (pour platefor hands and boots; spread plate for tails) in Tryptone Glucose Extract agar, and results were expressed as CFU/hand, CFU/cm2 and CFU/tail. The sodium hypochlorite solutions failed the UDM test at all concentrations, but were approved (DR >5) in the suspension test for at least one repetition. The benzalkonium chloride solutions were approved with both methods, with the best performance observed for the suspension method (DR >5log) at 10.000 mg/L. DR values were <0.8 (hands), <0.6 (boots) and <0.6 (tails). The two methods (UDM and Suspension) were in partial agreement regarding the approval of solutions, but the latter method yielded a greater number of approvals. Due to differences in the initial bacterial load, the hygienization procedures were efficient for hands and lobster tails but inefficient for boots. DR values were significantly higher for standard strains (S. aureus and E. coli) tested with the suspension method using sodium hypochlorite and benzalkonium chloride than for aerobic mesophiles following the hygienization of hands, boots and lobster tails sampled at the seafood processing facility.
2

ESTUDO EXPLORATÃRIO DA SOLDAGEM MIG/MAG COM DUPLO ARAME EMPREGANDO CORRENTE ALTERNADA / Exploratory Study of tandem GMA welding applying alternating current

Edson Frota Pessoa 25 June 2007 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / Este trabalho teve como objetivo o estudo exploratÃrio do processo MIG/MAG-DA-PI utilizando corrente alternada. Os ensaios foram executados em simples deposiÃÃo na posiÃÃo plana em chapas de aÃo baixo carbono com espessura de 3 mm utilizando arame eletrodo de 1,2 mm de diÃmetro. Foram realizados estudos sobre o nÃvel de corrente, tipo de onda aplicado em corrente alternada (CA-CP e CA-CC), a porcentagem de corrente alternada com o eletrodo na polaridade negativa (% CAEN), o sentido de deslocamento do eletrodo em relaÃÃo ao tipo de onda. Foi realizado tambÃm um estudo comparativo entre as soldagens realizadas em corrente alternada com corrente pulsada e sobre a disposiÃÃo dos eletrodos em relaÃÃo à direÃÃo de soldagem (âtandemâ e lado a lado). Foram avaliados os efeitos destes estudos nas caracterÃsticas geomÃtricas (penetraÃÃo, reforÃo e largura), na diluiÃÃo, na taxa de fusÃo do arame eletrodo, no aspecto superficial do cordÃo de solda e na microestrutura resultante na regiÃo de grÃos grossos da zona afetada pelo calor. Foi constatado que o aumento no nÃvel de corrente promove o aumento nas caracterÃsticas geomÃtricas, da diluiÃÃo e da taxa de fusÃo. A aplicaÃÃo de corrente alternada na soldagem MIG/MAG-DA-PI promoveu o aumento da taxa de fusÃo do arame, do reforÃo com a diminuiÃÃo da diluiÃÃo e da largura do cordÃo de solda. O aumento da % CAEN resultou no aumento do reforÃo, da taxa de fusÃo do arame, reduÃÃo da largura, da diluiÃÃo da solda e no refino da microestrutura. A aplicaÃÃo de corrente alternada no eletrodo anterior promoveu a reduÃÃo da diluiÃÃo com o aumento do reforÃo. Em comparaÃÃo com o uso da corrente pulsada, aplicaÃÃo de corrente alternada no processo MIG/MAG-DA-PI, para um mesmo nÃvel de corrente eficaz, resultou no aumento do reforÃo, da taxa de fusÃo do arame com a diminuiÃÃo da largura e da diluiÃÃo da solda. / The use of alternating current (or variable polarity) on the tandem GMAW process was investigated experimentally. Bead-on-plate test, in flat position, were carried out using a 1.2 mm diameter on mild steel sheet (3mm-thick). The level of welding current, waveform type applied in alternating current tandem GMAW: alternating-continuous current (AC-CC) and alternating-pulsed current (AC-PC), the percentage of alternating current in the negative polarity (% DCEN), the displacement direction of electrode applied related to waveform type. It was also carried out a comparative study between variable polarity and pulsed current in tandem GMAW and, a comparative study about the arrangement of electrodes in respect to the welding direction (tandem and side-by-side). The effects on welding geometric characteristics (penetration, reinforcement and width), weld dilution, electrode fusion rate and microstructure on coarsened grain heat affected zone (CG-HAZ) were evaluated. The experiments revealed that as current level increase, the geometrics characteristics, dilution and electrode fusion rate increased accordingly. The application of variable polarity in tandem GMAW process resulted in an increase on electrode fusion rate, reinforcement and, reduction of dilution and width of weld bead. Increasing % DCEN resulted in increase reinforcement and electrode fusion rate, reduction of dilution and width and, a refinement of microstructure. By applying variable polarity waveform on the trailing electrode, dilution is reduced and reinforcement is increased. Comparing welds made with pulsed current, the use of variable polarity in tandem GMAW process resulted in increase of reinforcement, electrode fusion rate and, reduction of width and dilution.

Page generated in 0.0231 seconds