• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 60
  • 1
  • Tagged with
  • 61
  • 61
  • 27
  • 20
  • 15
  • 14
  • 12
  • 10
  • 10
  • 10
  • 10
  • 10
  • 9
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação e caracterização da biodistribuição de nanopartículas magnéticas pelo encéfalo de ratos, pelo sistema BAC

Moretto, Gustavo Morlin. January 2017 (has links)
Orientador: José Ricardo de Arruda Miranda / Resumo: A barreira hematoencefálica é o principal obstáculo para que drogas possam chegar até o cérebro e realizar o tratamento de neuropataologias. Além disso, as doenças ligadas ao Sistema Nervoso Central (SNC) são a segunda categoria de doenças potencialmente fatais, ficando atrás apenas de problemas ligados ao sistema cardiovascular. Devido à baixa eficácia que os tratamentos comuns apresentam, o uso de nanomateriais para o tratamento e diagnóstico deste tipo de patologia tem ganhado grande interesse da área acadêmica. Este estudo buscou elucidar parâmetros relacionados à nanopartículas magnéticas (NPMs) no cérebro, assim como os efeitos do manitol – fármaco conhecido por sua ação diurética e grande uso no tratamento de anormalidades na pressão intracraniana - em parâmetros como o tempo de meia-vida das NPMs (T1/2), acúmulo em diferentes órgãos, intensidade máxima de sinal, entre outros. Foram utilizados três grupos de animais que receberam NPMs, sendo que em dois deles a administração das NPMs ocorreu 15 minutos e 30 minutos após a administração do manitol. Os resultados apresentaram diferentes intensidades máximas para cada grupo, assim como um diferente acúmulo de NPMs no baço e no sangue para animais que receberam manitol, indicando alterações causadas por este fármaco em sistemas biológicos. O sistema BAC se mostrou eficaz na detecção de NPMs no cérebro, assim como na posterior análise da biodistribuição destas em organimos vivos. Além disso, os resultados de biodistribuição... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The blood-brain barrier is the main obstacle for drugs to reach the brain and treat neuropathologies. In addition, diseases linked to the Central Nervous System (CNS) are the second category of potentially fatal diseases, behind only problems related to the cardiovascular system. Due to the low effectiveness that common treatments present, the use of nanomaterials for the treatment and diagnosis of this type of pathology has gained great interest in the academic area. This study sought to elucidate parameters related to magnetic nanoparticles (NPMs) in the brain, as well as the effects of mannitol - drug known for its diuretic action and great use in the treatment of abnormalities in intracranial pressure - in parameters such as the half-life time of NPMs (T1 / 2), accumulation in different organs, maximum signal intensity, among others. Three groups of animals that received NPMs were used, and in two of them the administration of the NPMs occurred 15 minutes and 30 minutes after the administration of mannitol. The results presented different maximum intensities for each group, as well as a different accumulation of NPMs in the spleen and blood for animals that received mannitol, indicating changes caused by this drug in biological systems. The BAC system proved to be effective in the detection of NPMs in the brain, as well as in the subsequent analysis of the biodistribution of these into living organism. In addition, the results of biodistribution and time of circulation fo... (Complete abstract click electronic access below) / Mestre
2

Estudo exploratório da soldagem MIG/MAG com duplo arame empregando corrente alternada / Exploratory study of tandem gma welding applying alternating current

Pessoa, Edson Frota 27 June 2007 (has links)
PESSOA, E. F. Estudo exploratório da soldagem MIG/MAG com duplo arame empregando corrente alternada. 2007. 137 f. Dissertação (Mestrado em Ciência de Materiais) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2007. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2016-03-31T13:57:08Z No. of bitstreams: 1 2007_dis_efpessoa.pdf: 10723066 bytes, checksum: 50216704fc33512373c196e96a7beb3e (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2016-04-01T19:08:44Z (GMT) No. of bitstreams: 1 2007_dis_efpessoa.pdf: 10723066 bytes, checksum: 50216704fc33512373c196e96a7beb3e (MD5) / Made available in DSpace on 2016-04-01T19:08:44Z (GMT). No. of bitstreams: 1 2007_dis_efpessoa.pdf: 10723066 bytes, checksum: 50216704fc33512373c196e96a7beb3e (MD5) Previous issue date: 2007-06-27 / The use of alternating current (or variable polarity) on the tandem GMAW process was investigated experimentally. Bead-on-plate test, in flat position, were carried out using a 1.2 mm diameter on mild steel sheet (3mm-thick). The level of welding current, waveform type applied in alternating current tandem GMAW: alternating-continuous current (AC-CC) and alternating-pulsed current (AC-PC), the percentage of alternating current in the negative polarity (% DCEN), the displacement direction of electrode applied related to waveform type. It was also carried out a comparative study between variable polarity and pulsed current in tandem GMAW and, a comparative study about the arrangement of electrodes in respect to the welding direction (tandem and side-by-side). The effects on welding geometric characteristics (penetration, reinforcement and width), weld dilution, electrode fusion rate and microstructure on coarsened grain heat affected zone (CG-HAZ) were evaluated. The experiments revealed that as current level increase, the geometrics characteristics, dilution and electrode fusion rate increased accordingly. The application of variable polarity in tandem GMAW process resulted in an increase on electrode fusion rate, reinforcement and, reduction of dilution and width of weld bead. Increasing % DCEN resulted in increase reinforcement and electrode fusion rate, reduction of dilution and width and, a refinement of microstructure. By applying variable polarity waveform on the trailing electrode, dilution is reduced and reinforcement is increased. Comparing welds made with pulsed current, the use of variable polarity in tandem GMAW process resulted in increase of reinforcement, electrode fusion rate and, reduction of width and dilution. / Este trabalho teve como objetivo o estudo exploratório do processo MIG/MAG-DA-PI utilizando corrente alternada. Os ensaios foram executados em simples deposição na posição plana em chapas de aço baixo carbono com espessura de 3 mm utilizando arame eletrodo de 1,2 mm de diâmetro. Foram realizados estudos sobre o nível de corrente, tipo de onda aplicado em corrente alternada (CA-CP e CA-CC), a porcentagem de corrente alternada com o eletrodo na polaridade negativa (% CAEN), o sentido de deslocamento do eletrodo em relação ao tipo de onda. Foi realizado também um estudo comparativo entre as soldagens realizadas em corrente alternada com corrente pulsada e sobre a disposição dos eletrodos em relação à direção de soldagem (“tandem” e lado a lado). Foram avaliados os efeitos destes estudos nas características geométricas (penetração, reforço e largura), na diluição, na taxa de fusão do arame eletrodo, no aspecto superficial do cordão de solda e na microestrutura resultante na região de grãos grossos da zona afetada pelo calor. Foi constatado que o aumento no nível de corrente promove o aumento nas características geométricas, da diluição e da taxa de fusão. A aplicação de corrente alternada na soldagem MIG/MAG-DA-PI promoveu o aumento da taxa de fusão do arame, do reforço com a diminuição da diluição e da largura do cordão de solda. O aumento da % CAEN resultou no aumento do reforço, da taxa de fusão do arame, redução da largura, da diluição da solda e no refino da microestrutura. A aplicação de corrente alternada no eletrodo anterior promoveu a redução da diluição com o aumento do reforço. Em comparação com o uso da corrente pulsada, aplicação de corrente alternada no processo MIG/MAG-DA-PI, para um mesmo nível de corrente eficaz, resultou no aumento do reforço, da taxa de fusão do arame com a diminuição da largura e da diluição da solda.
3

Otimização e aperfeiçoamento BAC pra estudos envolvendo o trato gastrintestinal

Agostinho, Marcelo Rodrigues [UNESP] 27 July 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-07-27Bitstream added on 2014-06-13T20:13:53Z : No. of bitstreams: 1 agostinho_mr_me_botib.pdf: 487460 bytes, checksum: e3edd62113cd3612c5b439f526eb253b (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A utilização de técnicas não invasivas, de baixo custo e inócuas ao indi-víduo proporcionam um grande desafio para o estudo do trato gastrintestinal. Métodos biomagnéticos como a BAC trazem todas essas vantagens e incluem a possibilidade de expansão para novos estudos, arranjos instrumentais e mo-delos biológicos. A consolidação dessa técnica nos últimos anos permitiu a ampliação dos estudos na área farmacêutica, avaliações após alterações nas condições fisiológicas e mesmo após administração de drogas, fornecendo subsídios para uma melhor interpretação dos parâmetros motores do trato gas-trintestinal. As imagens de traçadores e marcadores magnéticos no trato gas-trintestinal proporcionadas pela BAC foi um importante aspecto explorado, no entanto, houve a necessidade de aperfeiçoar a instrumentação para obter me-lhores e também novos resultados. A proposta de implementação de algumas melhorias nesta instrumentação através de implementação de novo arranjo de bobina excitadora, cancelamento de ruído respiratório e nova eletrônica de de-tecção permitiram que os dados in vitro e in vivo refletiram numa melhor quali-dade de sinais e imagens obtidos por este técnica. A BAC multi-sensores é uma ferramenta valiosa com vasta aplicabilidade para aplicação em tecnologia farmacêutica e em fisiologia do trato gastrintestinal / The use of non-invasive techniques, at low cost and harmless to the indi-vidual, provides a great challenge for the study of the gastrointestinal tract. Biomagnetic methods such as the BAC have all these advantages and also include the possibility of expanding to new studies, to instrumental ar-rangements and to biological models. The consolidation of this technique in re-cent years allowed the extension of studies in the pharmaceutical field, after rating changes in physiological conditions and even after drug administration, supporting a better interpretation of the motor parameters of the gastrointestinal tract. The images of tracers and magnetic markers in the gastrointestinal tract offered by the BAC was an important aspect explored. However, there was a necessity of improving the equipment in order to obtain new and better re-sults. The proposal to implement some improvements in this equipment through implementation of the new exciter coil arrangement, the cancellation of the noise of breathing, and the new electronics of detection have allowed that the data in vitro and in vivo reflected a better quality of signals and images obtained by this technique. The BAC multi-sensors is a valuable tool with wide applica-bility to pharmaceutical technology and physiology of the gastrointestinal tract
4

Uma contribuição ao estudo do motor de indução linear acionado por inversor (VSI) com corrente controlada

Serni, Paulo Jose Amaral 26 July 2018 (has links)
Orientador: Carlos Rodrigues de Souza / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-26T08:51:21Z (GMT). No. of bitstreams: 1 Serni_PauloJoseAmaral_M.pdf: 11751304 bytes, checksum: 5dae0b4541157756bfda0065af05606d (MD5) Previous issue date: 1999 / Resumo: Este trabalho objetiva avaliar o desempenho de um Motor de Indução Linear (MIL) Trifásico de Disco e um MIL em Arco, quando acionados por um Inversor de Freqüência Variável. Um Inversor Trifásico, com atuação especialmente concebida, é construído para que a corrente imposta pelo inversor ao motor seja mantida senoidal e com valor eficaz constante. São levantados dados relativos à força propulsora destes motores, em função da freqüência de acionamento. Os resultados obtidos através de simulação, utilizando um modelo unidimensional e um circuito elétrico equivalente corrigido quanto aos efeitos de extremidades, são comparados com os determinados experimentalmente. Análises da forma de onda da corrente nas fases do motor são executadas, para a determinação do seu conteúdo espectral / Abstract: The behavior of. a disc rotor induction motor and an arc stator induction motor (sector motor) is analyzed in this work as a result of feeding these machines with an inverter. The machines developed thrust as a function of the slip is obtained for different input frequencies. An equivalent circuit is used for the simulations. This circuit is obtained through the application of the one-dimensional theory to the modeling and accounts for the end effects always present in these machines. The phase curent wavefoms are analyzed for their harmonic contents. Experiment results were obtainded in laboratory and are presented for comparison with the simulations / Mestrado / Automação / Doutor em Engenharia Elétrica
5

Projeto via programação matematica e implementação de conversores CC-CA de frequencia variavel

Moreira, Julio Cesar, 1957- 14 July 2018 (has links)
Orientador : Celso Pascoli Bottura / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-14T19:54:32Z (GMT). No. of bitstreams: 1 Moreira_JulioCesar_M.pdf: 5681799 bytes, checksum: 64132c11cca7e4d071994682dc57ec5e (MD5) Previous issue date: 1983 / Mestrado / Mestre em Ciências
6

Biosusceptometria de corrente alternada para avaliação de esvaziamento gástrico e trânsito gastrintestinal

Quini, Caio César [UNESP] 27 July 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-07-27Bitstream added on 2014-06-13T21:01:41Z : No. of bitstreams: 1 quini_cc_me_botib.pdf: 604874 bytes, checksum: 6395053c8e32771be0353a9c71b35966 (MD5) / O trato gastrintestinal (TGI) constitui um grupo de importantes atividades motoras, es-sencial à vida. Uma série de metodologias é empregada no estudo dessas atividades e das patologias a elas associadas. No entanto, estas técnicas são geralmente invasivas, requerem cirurgia, inserção do cateter, ou, para a construção de um modelo temporal destas funções, demandam o sacrifício de uma série de animais na obtenção dos dados necessários. A Biosusceptometria de Corrente Alternada (BAC) é uma técnica biomagnética de baixo custo, portá-til, não-invasiva, livre de radiação ionizante, que pode ser utilizada para avaliar as proprieda-des do TGI pelo monitoramento da posição e concentração de materiais ferromagnéticos, usa-dos como marcadores magnéticos. O objetivo desta dissertação foi, através de um sistema BAC associado a marcadores magnéticos, apresentar uma nova forma de analisar propriedades do trato gastrintestinal, co-mo o esvaziamento gástrico e tempo de trânsito gastrointestinal, de alimentos sólidos e líqui-dos em modelos animais de pequeno porte. Um sistema dedicado foi construído para analisar estas propriedades. A instrumenta-ção consiste em dois pares de bobinas, um de referência e outro para a detecção. Cada par é composto por uma bobina de excitação e uma detecção. Uma linha de base fixa separa os pa-res de detecção e referência, e funciona também como suporte para a instrumenta-ção. Também é importante ressaltar que as bobinas de detecção são dispostas em uma confi-guração gradiométrica. Seu princípio de funcionamento baseia-se em um transformador de fluxo magnético, que o par (excitação e detecção), localizado mais distante da amostra magnética funciona co-mo uma referência para o sistema. Assim, quando se aproxima um material magnético... / The gastrointestinal tract (GIT) motor activities constitute an important group, essen-tial to life. A series of methodologies is employed in the study of these activities and its asso-ciated pathologies. However, these techniques are generally invasive, require surgery, catheter insertion or, in the temporal model construction issue, require the sacrifice of a series of ani-mals to record the necessary data. The Biosusceptometry of Alternate Current (BAC) is a low cost biomagnetic technique, portable, non-invasive and radiation free, which can be used to evaluate GIT properties by monitoring position and concentration of ferromagnetic materials when used as magnetic markers. The objective of this dissertation was to present a new way to measure GIT properties like gastric emptying and gastrointestinal transit time of both solid and liquid food in small animal models, using the BAC system associated with magnetic markers. A dedicated biosusceptometry system was constructed to analyze these particular properties. The instrumentation is constituted of two coil pairs, one for reference and another for detection. Each pair consists of an excitation coil and a detection one. A fixed baseline separates the detection and reference pairs, and works also as support to the instrumentation. It is also important to point that the detection coils are arranged in a gradiometric connection. Its working principle is based on a magnetic flux transformer, which the pair (excita-tion and detection) located farther from the sample works as a reference. Thus, when ap-proaching a magnetic material to the sensor, the balance created between the two faces of the sensor will be broken. This imbalance can be measured, digitalized and acquired. The mag-netic tracer used in the liquid transit determination was a commercial... (Complete abstract, click electronic access below)
7

Avaliação multinstrumental em modelo animal das atividades contráteis do estômago e do intestino delgado

Zandona, Ednaldo Alexandre. January 2017 (has links)
Orientador: José Ricardo de Arruda Miranda / Resumo: Atividades motoras gástricas e intestinais representam um complexo grupo de funções essenciais à vida, sendo o estudo de suas características objeto de grande interesse da comunidade científica. Estudos sobre essas atividades foram intensificados em decorrência da elevada prevalência de indivíduos com sintomas atribuíveis às anormalidades dessas funções. Além disso, uma vez que os mecanismos das disfunções motoras do trato gástrico e intestinal ainda não se acham plenamente esclarecidos, faz-se necessária a busca de novas abordagens. Várias metodologias têm sido empregadas na avaliação dos parâmetros contráteis da motilidade gástrica e intestinal – uso de strain gage, métodos barométricos, elétricos e cintilográficos. A biosusceptometria de corrente alternada é um método alternativo eficaz e que apresenta grandes vantagens em relação aos demais e nesse trabalho foi comparada a técnicas consideradas padrão na avaliação da oscilação tônica do estômago e dos diferentes trechos do intestino delgado. Os resultados apresentaram valores fortemente correlacionados e concordantes entre si, permitindo quantificar a atividade tônica e o espectro de frequências predominantes nos diferentes segmentos do intestino delgado. Este trabalho aplicou uma metodologia eficiente na avaliação da oscilação tônica do estômago e do espectro de frequências predominantes no duodeno, jejuno e íleo. / Doutor
8

Aprendizagem de conceitos físicos relacionados com circuitos elétricos em regime de corrente alternada com uso da placa Arduino

Dröse Neto, Breno January 2013 (has links)
O objetivo deste trabalho foi investigar as dificuldades encontradas pelos alunos na aprendizagem de circuitos elétricos em regime de corrente alternada (CA). Especificamente investigamos: i) dificuldades de aprendizagem em relação aos conceitos de reatância e impedância presentes em circuitos RLC de CA; ii) a contribuição da visualização da diferença de fase entre a tensão no capacitor/indutor e a tensão da fonte de CA na compreensão dos processos físicos envolvidos nesses elementos do circuitos e iii) a contribuição da análise da tensão nos elementos presentes em circuitos elétricos (resistivos, RC, RL e RLC) em tempo real através da placa Arduino para o entendimento do comportamento desses em regime de corrente contínua e alternada. Para tanto foi desenvolvido, amparado na Teoria da Aprendizagem Significativa de Ausubel, um material didático constituído por: i) um aparato experimental que, por meio de uma placa Arduino conectada a um computador, fornece gráficos em tempo real do comportamento da tensão em função do tempo nos diferentes tipos de circuitos trabalhados; ii) questionários online, para a determinação do conhecimento prévio dos alunos, cujas respostas serviram para o professor orientar a sua exposição em aula, à semelhança do que ocorre na estratégia de “Ensino sob Medida” (EsM) e iii) e guias de atividades para que os alunos, trabalhando em aula em pequenos grupos com a metodologia “Predizer, Interagir e Explicar” (P.I.E.), explorassem os circuitos elétricos que construíam com a placa Arduino. O equipamento experimental foi utilizado pelo professor em pequenas demonstrações e, especialmente, pelos alunos em todas as atividades realizadas em pequenos grupos, na etapa Interagir do P.I.E. Foram realizados dois estudos: o primeiro, do tipo piloto e duração de 9h, com alunos do curso de licenciatura em Física da UNIPAMPA teve o objetivo de testar e melhor material didático desenvolvido; já o segundo, um estudo de caso exploratório com alunos da Física (Bacharelado e Licenciatura) da UFRGS matriculados na disciplina de Eletrônica básica, com duração de 6 horas, teve o objetivo de responder às questões propostas na pesquisa. Em ambos os estudos todos os alunos já haviam cursado a disciplina de Física III, Eletromagnetismo, tendo os conhecimentos básicos necessários para a aprendizagem dos conceitos de impedância e reatância. Os resultados da nossa análise qualitativa mostram que os estudantes eram capazes de argumentar sobre a diferença de fase entre a tensão nos elementos constituintes do circuito RLC de CA, inclusive dois meses após o término das atividades. De modo geral, para os aprendizes o capacitor/indutor não é um agente capaz de restringir a corrente elétrica em um circuito de CA, assim como ignoram a contribuição do resistor para a impedância. Os resultados apontam que a visualização da diferença de fase entre a tensão no capacitor/indutor seja um agente facilitador da aprendizagem dos processos físicos envolvidos nesses elementos, bem como auxiliam no entendimento e argumentação sobre a fase existente entre os componentes do circuito RLC de CA. A principal contribuição da análise através da placa Arduino foi seu rápido feedback e fácil manuseio, que aliado à metodologia adotada auxiliaram no entendimento das questões propostas aos alunos. Entretanto, salientamos que os resultados são preliminares e que mais esforços deverão ser envidados para subsidiar as conclusões da presente pesquisa. / The purpose of this study is to investigate the difficulties related to the learning of basic concepts of alternating current circuits. In particular, we investigated: i) learning difficulties associated with the concepts of reactance and impedance in RLC circuits (AC); ii) the contribution of real-time graphical visualization of phase’s difference between the voltage on the capacitor/inductor and on the AC source to understand the physical processes involved in the electric elements the circuits and iii) the contribution of a real-time voltage analysis using an Arduino board to compare the behavior of electrical elements in a circuit whether with direct or alternating current source. To answer our research questions a didactical material was developed based on Ausubel's Meaningful Learning Theory and it consists of: i) an experimental setup (Arduino board connected to a computer); ii) online questionnaires to detect the student’s misconceptions and iii) student’s activity guides using the "Predict, Interact and Explain" methodology to explore electrical circuits mounted on a protoboard. The experimental equipment was used by the teacher in short demonstrations, and by the students while developing experimental activities in small groups. A pilot study was conducted with undergraduate Physics students to test and improve the developed instructional material. This study was conducted at the Federal University of Pampa (UNIPAMPA-Brazil) and lasted 9 hours. Then an exploratory case study to answer the research questions was conducted with undergraduate physics majors at the Federal University of Rio Grande do Sul (UFRGS-Brazil) enrolled in a basic electronics course. This study lasted 6 hours. In both studies, all students had the basic knowledge needed for learning the concepts of impedance and reactance. The qualitative results show that students were able to argue on the phase difference between the voltages on the elements of the AC RLC circuit, even two months after the end of the activities. In general, the apprentices considered that the capacitor/inductor does not restrict the electric current in an AC circuit, as well as ignore the resistor's contribution to the impedance. The results suggest that the real-time graphical visualization of the voltage on the capacitor/inductor helps the students to understand the physical processes involved in these elements and, specifically, to understand the phase’s difference between the components of the AC RLC circuit. The main contribution of the Arduino board is related to its quick feedback and easy handling. This, combined with the didactical methodology we used, helped to foster students’ understanding. However, our results are preliminary and more efforts should be made to support the conclusions of this research.
9

Tomografia por biosusceptometria de corrente alternada

Fonseca Filho, Paulo Roberto da [UNESP] 03 February 2014 (has links) (PDF)
Made available in DSpace on 2015-05-14T16:53:14Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-03Bitstream added on 2015-05-14T16:59:09Z : No. of bitstreams: 1 000822024_20160203.pdf: 74282 bytes, checksum: 81fcaba4dabd99298046b62189ca92be (MD5) Bitstreams deleted on 2016-02-03T15:35:12Z: 000822024_20160203.pdf,. Added 1 bitstream(s) on 2016-02-03T15:35:53Z : No. of bitstreams: 1 000822024.pdf: 798249 bytes, checksum: cf24aa6eedaa8b219d13e0e5cf032c2e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A busca por novos métodos de imagens, principalmente os livres de radiação ionizante, são importantes tanto pelas instrumentações, quanto para as finalidades. A Biosusceptometria de |Corrente Alternada (BAC) possui versatilidade, sensibilidade, baixo custo e têm sido amplamente utilizada na aquisição de imagens para estudos nas áreas de gastrenterologia, fisiologia, farmacologia e farmácia. O objetivo deste trabalho foi caracterizar sistemas de BAC na produção de imagens tomográficas de objetos simuladores, propondo a viabilidade da técnica de tBAC - tomografia por biosusceptometria de Corrente Alternada. Para tanto, os gradiômetros de dois sistemas BAC com 13 e 37 canais com compensação de campo de excitação foram avaliados quanto à sua sensibilidade e resolução para produzir imagens de simuladores de barras e cilíndri-cos. Foi possível reconstruir imagens de todos os objetos com boa correlação entre a imagem e as caracte-rísticas físicas dos objetos (forma e concentração de traçador magnético). As melhores imagens foram pro-duzidas quando foi utilizada aquisição multicanal no sistema de BAC com 37 sensores utilizando compen-sação de campo, os quais possuem menores diâmetros. Dessa forma verificou-se que os sistemas BAC podem ser empregados com sucesso para produzir imagens tomográficas de objetos com pequena quanti-dade de traçador magnético, o que viabiliza sua aplicação futura em pequenos animais, farmacotecnia ou ainda ensaios não destrutivos / The development of new imaging methods, especially those that are free of ionizing radiation, constitute a very important topic because for both instrumentation development and its applications. The Alternating Current Biosusceptometry (ACB) has versatility, sensibility and low cost and has been widely used on image acquisition on gastroenterology, physiology, pharmaceutics and pharmacology researches. The aim of this project was to characterize ACB systems to produce tomographic images of simulating objects ver-ifying the technical viability of the AC Biosusceptometry Tomography (ACBT). The capability of ACB gradiometers of 13 and 37 channel systems with compensation field to reconstruct images of bars and cy-lindrical phantoms were evaluated, especially sensibility and resolution. It was possible to reconstruct im-ages from all objects with good correlation between the image and the phantom (geometry and magnetic tracer concentration). Better results were observed while using multichannel acquisition on 37-channel sys-tem with active excitation magnetic field. Therefore we verified that ACB systems can be successfully used on tomographic imaging of objects with small quantities of magnetic tracer, which is viable to future ap-plication on small animal physiology, pharmaceutics or non-destructive evaluation research
10

Tomografia por biosusceptometria de corrente alternada /

Fonseca Filho, Paulo Roberto da. January 2014 (has links)
Orientador: José Ricardo de Arruda Miranda / Banca: Oswaldo Baffa Filho / Banca: Roberto Morato Fernandez / Banca: Fernando Gomes Romeiro / Banca: Valmir Fadel / Resumo: A busca por novos métodos de imagens, principalmente os livres de radiação ionizante, são importantes tanto pelas instrumentações, quanto para as finalidades. A Biosusceptometria de |Corrente Alternada (BAC) possui versatilidade, sensibilidade, baixo custo e têm sido amplamente utilizada na aquisição de imagens para estudos nas áreas de gastrenterologia, fisiologia, farmacologia e farmácia. O objetivo deste trabalho foi caracterizar sistemas de BAC na produção de imagens tomográficas de objetos simuladores, propondo a viabilidade da técnica de tBAC - tomografia por biosusceptometria de Corrente Alternada. Para tanto, os gradiômetros de dois sistemas BAC com 13 e 37 canais com compensação de campo de excitação foram avaliados quanto à sua sensibilidade e resolução para produzir imagens de simuladores de barras e cilíndri-cos. Foi possível reconstruir imagens de todos os objetos com boa correlação entre a imagem e as caracte-rísticas físicas dos objetos (forma e concentração de traçador magnético). As melhores imagens foram pro-duzidas quando foi utilizada aquisição multicanal no sistema de BAC com 37 sensores utilizando compen-sação de campo, os quais possuem menores diâmetros. Dessa forma verificou-se que os sistemas BAC podem ser empregados com sucesso para produzir imagens tomográficas de objetos com pequena quanti-dade de traçador magnético, o que viabiliza sua aplicação futura em pequenos animais, farmacotecnia ou ainda ensaios não destrutivos / Abstract: The development of new imaging methods, especially those that are free of ionizing radiation, constitute a very important topic because for both instrumentation development and its applications. The Alternating Current Biosusceptometry (ACB) has versatility, sensibility and low cost and has been widely used on image acquisition on gastroenterology, physiology, pharmaceutics and pharmacology researches. The aim of this project was to characterize ACB systems to produce tomographic images of simulating objects ver-ifying the technical viability of the AC Biosusceptometry Tomography (ACBT). The capability of ACB gradiometers of 13 and 37 channel systems with compensation field to reconstruct images of bars and cy-lindrical phantoms were evaluated, especially sensibility and resolution. It was possible to reconstruct im-ages from all objects with good correlation between the image and the phantom (geometry and magnetic tracer concentration). Better results were observed while using multichannel acquisition on 37-channel sys-tem with active excitation magnetic field. Therefore we verified that ACB systems can be successfully used on tomographic imaging of objects with small quantities of magnetic tracer, which is viable to future ap-plication on small animal physiology, pharmaceutics or non-destructive evaluation research / Doutor

Page generated in 0.1039 seconds