Análise de proteção de linhas de transmissão através de relés numéricos e uso de models externos no ATP (Alternative Transient Program)

Fabián Espinoza, Renzo Grover [UNESP] 18 February 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-02-18Bitstream added on 2014-06-13T19:08:07Z : No. of bitstreams: 1 fabianespinoza_rg_me_ilha.pdf: 869619 bytes, checksum: 3c82572569bc2349669cb3765fb65c95 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Ensino Pesquisa e Extensão de Ilha Solteira (FEPISA) / Neste trabalho apresenta-se uma metodologia para obter um ambiente interativo de simulação com ferramentas que permitam fazer análises de sistemas de proteção como estudos de coordenação e analises pós falta. As ferramentas estão baseadas no programa de simulação de transitórios eletro- magnéticos EMTP/ATP e na linguagem de programação ANSI C, sobre a plataforma de software livre GNU/Linux. Esta metodologia pode ser implementada, da mesma forma, em qualquer plataforma Windows sobre a qual possa funcionar o EMTP/ATP e o pacote ATP/MingW. Assim, implementou- se um relé de distância numérico através de modelos externos (“foreign models”). Ilustra-se também como usar arquivos no formato COMTRADE na análise com EMTP/ATP. Dessa forma foi possível analisar o comportamento do relé implementado tendo como entradas os sinais de tensões e correntes correspondentes aos eventos reais. Os sinais de disparo, assim como os demais componentes do relé, foram testados usando um sistema teste de referência do Power System Relaying Committee da PES-IEEE e os sinais de faltas reais do Sistema Elétrico Interligado da Colômbia. Por fim, foi feito um estudo de coordenação. Os resultados são apresentados e discutidos. A metodologia proposta pode ser usada para desenvolver qualquer componente ou elemento de controle dentro de um sistema elétrico, onde haja a necessidade de usar o EMTP/ATP para simular condições específicas de operação do sistema elétrico, complementando a simplicidade da linguagem MODELS com a portabilidade e potencialidade da linguagem C / This work presents the methodology to obtain an environment of interactive simulation with tools to perform analysis of protection systems, coordination studies and analysis post fault. These tools are based on the program for electromagnetic transients EMTP/ATP and in ANSI C programming language used in the free GNU/Linux software platform. The same methodology can be followed to be used on any Windows Operating System that can run EMTP/ATP and the package ATP/MingW. Then, for this, a numerical distance relay was implemented by means of foreign models using C programming language. It also shows how to use COMTRADE files in analysis with EMTP / ATP. Thus it was possible to analyze the behavior of the implemented relay with voltage and current signals of real events as inputs. The trip signals, like the other components of the relay, were tested using a testing reference system of Power System Relaying Committee of PES-IEEE and the signals of real faults of Inter- connected Electric System of Colombia. Finally, a coordination study was made. The results are presented and discussed. This methodology could also be used to develop any component or control element within an electrical system that one may need for a particular use; therefore, compensating the simplicity of the language MODELS with the flexibility and portability of C programming language
12

Algoritmo de alto desempenho para proteção numérica de linhas de transmissão imune a oscilações de potência / High-performance algorithm for numerical protection of transmission lines immune to power swings

Morais, Adriano Peres de 04 May 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This Doctoral Thesis proposes a new methodology for transmission line protection tolerant to power swings. The algorithm developed has the ability to detect, classify and locate all fault types with and without power swings, including those that produce high values of fault resistance. In a first step, it is proposed a fault distance estimator based on the leastsquare curve fitting. The fault locator, for protection proposes, was modeled by a series R-L circuit and differential equations. In a second step, the main causes and consequences of power swings in transmission lines distance relays are introduced. Also in this context, techniques to minimize these effects are presented. Besides, computer simulations of power swings, with different fault scenarios, were carried out to realize comparative analyses between the methods. The results show that none of the methods is efficient in all scenarios. Hence, there is still some concern about the performance of the protection methods against power swings. In a third step, it was developed an algorithm for numerical protection in transmission lines immune to power swings. The detection and classification steps are based on Mathematical Morphology. In order to obtain a safer operation of the relay, especially in the boundaries of threshold set, a counting strategy was developed. The main innovation of the work is based on difference of behavior of the exponentially decaying component (dc component) during a fault and during a power swing. The dc component, obtained by means of morphological filter, is used as a tripping criterion. Finally, in order to evaluate the algorithm performance, tests with different fault and power swings scenarios were performed. The results show that the technique has the speed and safety required even during power swings due to the simplicity of the algorithm used in mathematical operations. / Neste trabalho propõe-se uma nova metodologia de proteção de linhas de transmissão, tolerante as oscilações de potência. O algoritmo desenvolvido tem a capacidade de detectar, classificar e localizar todos os tipos de faltas, com e sem a presença de oscilações de potência, inclusive aquelas que produzem altos valores de resistência de falta. Em uma primeira etapa com o emprego do método de ajuste de curvas por mínimos quadrados desenvolve-se um estimador para localizar a posição das faltas. Para fins de proteção, este é modelado por meio de um circuito R-L série representado por suas equações diferenciais. Em uma segunda etapa são apresentadas as principais causas das oscilações de potência, bem como suas consequências para os relés de distância de linhas de transmissão. Ainda neste contexto, são apresentadas, analisadas e comparadas algumas técnicas destinadas a minimizar estes efeitos. Essas técnicas foram testadas por meio de simulações computacionais, sob condições de oscilação de potência com e sem a presença de curtos-circuitos, considerando-se diversos valores de carregamento e frequências de oscilação. Os resultados mostraram que nenhum método é totalmente eficiente para todos os cenários. Desse modo, ainda há algumas incertezas sobre o desempenho das técnicas de proteção contra as oscilações de potência existentes. Em uma terceira etapa, foi desenvolvido um algoritmo para proteção numérica de linhas de transmissão imune as oscilações de potência. A metodologia faz uso da Morfologia Matemática nas etapas de detecção e classificação das faltas. De modo a se obter uma maior segurança na operação do relé, especialmente na região próxima ao limiar de operação, incorporou-se uma estratégia de contagem diferente das tradicionais. A principal contribuição do trabalho relaciona-se com a análise da diferença comportamental da componente exponencial decrescente (componente dc) para uma situação de falta e de oscilação de potência. Ou seja, a componente dc, obtida por meio de um filtro morfológico, é utilizada como critério de disparo do relé de distância. Para avaliar o desempenho do algoritmo desenvolvido, uma série de testes com diferentes cenários de faltas com e sem a presença de oscilações de potência foram realizadas. Devido à simplicidade das operações matemáticas utilizadas no algoritmo, a técnica apresenta segurança e velocidade na sua operação, mesmo durante oscilações de potência.
13

Performance Evaluation Of Distance Relays For FACTS Compensated Transmission Lines

Maturu, Suresh 03 1900 (has links) (PDF)
With limited enhancement or expansion of the transmission infrastructure, the contemporary power systems are operating under more stressed conditions. It becomes important to fully utilize the existing transmission system to supply load demand as much as possible, thus eliminating or reducing the need for new transmission investment. Flexible AC Transmission System (FACTS) technology provides an alternative to fully utilize the existing transmission lines as well as new and upgraded lines, by controlling power and also enhancing the power transfer capability of transmission lines. However, the implementation of FACTS controllers in the transmission system has introduced new power system dynamics that must be addressed in the area of power system protection, such as rapid changes in line impedance, power angle, line currents, transients introduced by the occurrence of fault and associated control action of the FACTS controller. Therefore, the performance of the protection system must be carefully analyzed in the presence of FACTS controllers. The thesis aims at evaluating the performance of distance relays when different types of FACTS controllers, in particular Voltage Source Converter (VSC) based FACTS controllers, are incorporated at the midpoint of the transmission system to achieve voltage profile improvement and power transfer capability. The detailed models of these controllers and their control strategies are described. The presence of FACTS controllers in the loop affects both steady state and transient components of voltage and current signals. The rapid response of FACTS controllers to different power system configurations significantly affects the apparent impedance seen by distance relays. The apparent impedance seen by distance relays would be different from that of the system without FACTS controller. Due to this, the distance relay may malfunction, resulting in unreliable operation of the power system during faults. Furthermore, the effect of FACTS controllers on distance relay operation depends on the type of FACTS controller used, the application for which it has been installed and its location in the power system. The distance relay is evaluated for different loading conditions and for various fault conditions. Simulation studies are carried out using PSCAD/EMTDC based transient simulation package.
14

The impacts of series compensated EHV lines on distance protection, and a proposed new mitigation solution

Shah, Syed Arif Ullah January 2017 (has links)
Series compensation is extensively applied to the transmission lines to increase the power transfer capability of transmission lines, reduce transmission losses, improve voltage profiles, and improve power oscillation damping and transient stability of power systems. But it modifies the apparent impedance of the transmission lines during fault conditions and might cause the distance protection of transmission lines to encounter directional discrimination issues and reach problems. The non-linear characteristic of metal oxide varistor in series compensation model creates further complexity to the fault analysis and might affects the performance of conventional distance protection scheme. The distance protection issues in the series compensated lines need to be addressed for the reliable and sustainable operation of power system.The directional discrimination issues related to current inversion and voltage inversion phenomenon, and reach problems related to sub-synchronous oscillation phenomenon are addressed in this thesis report. This report aims to analyse the impacts of series compensation on the performance of conventional distance relays, and proposes a new protection solution to mitigate the shortcomings of distance relays in the series compensated lines. The proposed new protection solution includes: new tripping characteristic of quadrilateral distance relays to cope with the steady-state reach problems due to current or voltage inversion, and a new high-pass filtering technique to handle the transient reach problems due to SSO.The proposed new protection algorithm is developed in MATLAB. The performance of new protection algorithm is evaluated by simulating a 500 kV two-source power system with a 200 km series compensated line in EMTDC/ PSCAD (Manitoba Hydro). The proposed new protection solution is found to be beneficial. / Seriekompensation tillämpas i stor utsträckning på överföringsledningarna för att öka överföringsförmågan hos överföringsledningar, minska överföringsförluster, förbättra spänningsprofiler och förbättra effektdämpning och övergående stabilitet hos elsystem. Men det ändrar transmissionslinjernas uppenbara impedans under felförhållanden och kan orsaka att distansskydd för överföringsledningarna stöter på diskrimineringsproblem och uppnår problem. Den icke-linjära egenskapen hos metalloxidvaristor i seriekompensationsmodell skapar ytterligare komplexitet för felanalysen och kan påverka prestandan hos konventionella distansskyddssystem. Distansskydd problemen i seriekompenserade linjer måste lösas för en pålitlig och hållbar drift av elsystemet. De riktningsdiskrimineringsproblem som är relaterade till det aktuella inversions- och spänningsinversionsfenomenet och uppnår problem relaterade till subsynkron oscillationsfenomen tas upp i denna avhandlingsrapport. Denna rapport syftar till att analysera effekterna av seriekompensation för prestanda hos konventionella distansreläer och föreslår en ny skyddslösning för att mildra bristerna i distansreläerna i seriekompenserade linjer. Den föreslagna nya skyddslösningen innefattar: Ny utlösningskaraktäristik för fyrsidig distansreläer för att klara avståndet med stillastående / räckvidden på grund av ström- eller spänningsinversion och en ny högpassfiltreringsteknik för hantering av övergående över- Nå problem på grund av SSO. Den föreslagna nya skyddsalgoritmen har utvecklats i MATLAB. Utförandet av den nya skyddsalgoritmen utvärderas genom simulering av ett 500 kV två-källa kraftverk med en 200 km serie kompenserad linje i EMTDC / PSCAD (Manitoba Hydro). Den föreslagna nya skyddslösningen har visat sig vara fördelaktig.
15

Distanční ochrana využívající digitální vstupní data / Distance Protection Design Using Digital Input Data

Wannous, Kinan Hasan Wafaa January 2020 (has links)
Standard IEC 61850-9-2 definuje přenos vzorkovaných měřených hodnot (sampled measured values, SMV) prostřednictvím sítě Ethernet a využití SMV získaných ze slučovacích jednotek nebo přístrojových transformátorů. Implementace IEC 61850-9-2 závisí na vlastnostech datového souboru, jakými jsou časová synchronizace, počet vzorků a časový interval. Dizertační práce je zaměřena na algoritmy chránění a analýzu vlivu standardu IEC61850-9-2LE na fyzická zařízení ochran s analogově/digitálními vstupními daty o proudu a napětí. S ohledem na narůstající míru interakce mezi fyzickými zařízeními a komunikačními prvky byl navržen test pro analýzu komunikace pro rozvodnu využívající konvenční metody (analogové vstupy) a metody digitální založené na standardu IEC 61850-9-2. Práce dále popisuje funkci slučovací jednotky využívající standard IEC61850-9-2LE. Navržená metoda definuje zdroj SMV a analyzuje přenos dat. V rámci práce byl za využití softwaru Matlab naprogramován algoritmus ochrany. Vytvořený model je schopen vyhodnotit vliv harmonického zkreslení na funkci digitálních ochran a vliv přesycení proudového transformátoru na distanční ochranu. V práci jsou zhodnoceny i možnosti zrychlení testování systémů chránění s využitím neuronové sítě. Závěrečná kapitola se zabývá aplikacemi v reálném čase, využívajícími data z rozvodny v blízkosti Vysokého učení technického v Brně. K přenosu dat z rozvodny do univerzitní laboratoře je zde využíváno SMV přenášených optickým kabelem o délce 16 km. Aplikace je vytvořena v programu Matlab a je schopna číst data z ethernetového portu, dekódovat je, převést z formátu ASCII do desítkové soustavy a poté vykreslit průběhy proudu a napětí. Mezi vlastnosti aplikace se řadí jednoduchost použití, schopnost implementace funkcí distanční ochrany, výpočet RMS hodnot proudu a napětí a harmonického zkreslení, harmonická analýza prostřednictvím rychlé Fourierovy transformace a výpočet impedance poruchové smyčky. Všechny výpočty běží v reálném čase a provedena je i citlivostní analýza modelu.