• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 97
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • Tagged with
  • 99
  • 60
  • 33
  • 27
  • 26
  • 23
  • 22
  • 21
  • 19
  • 16
  • 16
  • 15
  • 15
  • 15
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

"Avaliação dimensional da região palatina em modelos de revestimento, após duplicação dos modelos de gesso para a confecção da estrutura metálica da prótese parcial removível, em função dos materiais duplicadores, revestimentos e da profundidade da abóbada palatina" / Dimensional evaluation of the palatal area in investment casts after the duplication of stone casts for removable partial denture framework construction in relation to the duplicating materials, investments and depth of the palatal vault.

Calamita, Marcelo Alexandre 03 February 2005 (has links)
O objetivo deste estudo foi avaliar a região palatina em modelos de revestimento, após duplicação do modelo de gesso para a confecção da estrutura metálica da prótese parcial removível, em função dos materiais duplicadores, revestimentos e da profundidade da abóbada palatina. Foram utilizados 12 modelos mestres de gesso com duas diferentes profundidades da abóbada palatina, sendo seis de palato raso e seis de palato profundo. Os métodos de uplicação utilizados foram: A) Hidrocolóide reversível com revestimento aglutinado por sílica (GEL_SIL); B) Hidrocolóide reversível com revestimento aglutinado por fosfato (GEL_FOS) e C) Silicone de adição com revestimento aglutinado por fosfato (ADI_FOS). Assim, a partir de cada modelo mestre foi obtido um modelo de revestimento para cada um dos métodos descritos acima, sendo os 48 modelos resultantes aferidos com o aparelho de medição tridimensional de coordenadas e os dados analisados estatisticamente pelo método split-plot. Avaliando-se os resultados obtidos concluiu-se que: 1) Todos os métodos de duplicação produziram algum grau de imprecisão nos locais avaliados; 2) O método GEL_FOS apresentou mínimas diferenças médias em relação ao modelo mestre; 3) O método GEL_SIL apresentou diferenças médias positivas em relação ao modelo mestre, não estatisticamente significativas em relação ao método GEL_FOS; 4) O método ADI_FOS apresentou diferenças médias negativas em relação ao modelo mestre, estatisticamente significativas em relação aos métodos GEL_FOS e GEL_SIL e 5) A profundidade da abóbada palatina não influenciou significativamente os resultados obtidos. / The aim of this study was to evaluate the palatal area in investment casts after the duplication of stone casts in relation to the duplicating materials, investments and the depth of the palatal vault. Twelve master stone casts were used with two different palatal vault depths, six with a shallow palatal vault and six with a deep palatal vault. The duplicating methods used were: A) Reversible hydrocolloid with silica bonded investment (GEL_SIL); B) Reversible hydrocolloid with phosphate bonded investment (GEL_FOS), and C) Addition silicone with phosphate bonded investment (ADI_FOS). Thus, one investment cast was obtained from each master cast for each of the methods described above. The 48 resulting models were measured with a three-dimensional coordinate measurement machine, and the data were analyzed by the split-plot method. After evaluating the results we concluded that: 1) All investment casts showed some degree of distortion in the areas measured; 2) The GEL_FOS method showed the smallest average differences in relation to the master cast; 3)The GEL_SIL method showed positive, not statistically significant average differences in relation to the GEL_FOS method; 4) The ADI_FOS method showed negative, and statistically significant differences in relation to the GEL_FOS and GEL_SIL methods, and 5) The depth of the palatal vault did not influence the results significantly.
22

Uso de pseudomedidas em estimador de estados para cálculo de distorção harmônica em sistemas elétricos

Pulz, Lucas Tupi Caldas January 2017 (has links)
A maior presença de correntes harmônicas no sistema de distribuição, principalmente devido à geração distribuída, tem chamado atenção sobre suas possíveis consequências. O trabalho apresenta um método para a avaliação de harmônicas em um sistema elétrico através de um estimador de estados. A proposta é um método de supervisão da rede de distribuição utilizando o menor número de medidores possível. Isso foi feito identificando topologias de rede que viabilizam o uso de pseudomedidas no lugar de medidores. O método é aplicado a um estudo de caso baseado no modelo IEEE 13 barras e os resultados do estimador de estados foram comparados a uma simulação. Também é feita uma análise de sensibilidade do código, observando os resultados quando se adicionam erros sobre as medidas e sobre os parâmetros das linhas do sistema. / The growth of harmonic currents in distribution system, mainly due the distributed generation, is calling attention of the specialists to its possible consequences. This work presents a method to assessment of harmonics in an electric power system through a state estimator. The proposal is a method to monitor the distribution network using as few measurement devices as possible. It was performed identifying network topologies where a pseudomeasurement can replace a measurement device. The method was applied to a study case based on the IEEE 13 buses model and its results were compared to a simulation. A sensitivity analysis of the code also was performed, errors were added to measurements and lines parameters to assess the errors in the state estimator results.
23

Análise das relações entre resistividade elétrica, vazão e parâmetros físico-químicos para o aquífero livre na região de Corumbataí (SP) /

Rosa, Fernanda Teles Gomes. January 2017 (has links)
Orientador: César Augusto Moreira / Banca: Fábio Braz Machado / Banca: Andresa Oliva / Resumo: A água subterrânea quando objeto de consumo humano obedece a parâmetros de qualidade, determinados por órgãos responsáveis em cada região. Poços do tipo cacimba, de escavação manual, e por vezes não regulamentados, podem sofrer da alteração dos parâmetros geoquímicos e como consequência a diminuição da qualidade da água. Sob a problemática de alta salinidade evidenciada por parte dos moradores nos municípios de Corumbataí e Rio Claro no interior do estado de São Paulo, foram realizadas aquisições de dados geofísicos por meio do método eletrorresistivo e coletados dados físico-químicos das águas dos poços. A captação de água subterrânea nestes poços é sob a unidade geológica da Formação Corumbataí marcada pela presença de siltitos e argilitos. A quantificação de parâmetros como os sólidos totais dissolvidos, condutividade elétrica, pH e Eh e vazão, são determinantes para caracterização do ambiente hidrogeológico. Para este trabalho, foram coletados dados geoquímicos de 18 poços e realizadas aquisições geofísicas com a técnica de tomografia elétrica concomitantes, com o intuito de possível correlação entre os parâmetros. Em uma análise geral nos dados físico-químicos é possível notar que os dados referentes aos parâmetros de sólidos totais dissolvidos e condutividade elétrica medidos nos poços, são correlacionados diretamente, devido a facilidade ao trânsito de corrente elétrica em soluções salinas. O resultado do processamento das aquisições geofísicas foi divido em quatro grupos distintos, que variam de acordo com as características quanto ao parâmetro físico de resistividade. Com a realização de três arranjos de campo distintos, Schlumberger, Wenner e Dipolo-dipolo, a resposta geofísica é diferente para cada arranjo. Em determinadas linhas ocorrem diferenças entre as três seções para mesmo ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Groundwater when subject to human consumption obeys quality parameters, determined by responsible bodies in each region. cacimba wells, manually excavated, and sometimes unregulated, can suffer from the alteration of the geochemical parameters and as a consequence the decrease of water quality. Under the problem of high salinity evidenced by the residents in the municipalities of Corumbataí and Rio Claro in the interior of the state of São Paulo, geophysical data were acquired through the eletrorresistivo method and physicochemical data were collected from well water. The abstraction of groundwater in these wells is under the geological unit of the Corumbataí Formation marked by the presence of siltstones and argillites. The quantification of parameters such as total dissolved solids, electrical conductivity, pH and Eh and flow rate are determinant for characterization of the hydrogeological environment. For this work, geochemical data were collected from 18 wells and geophysical acquisitions were carried out using the concomitant electrical tomography technique, with the aim of possible correlation between the parameters. In a general analysis of the physicochemical data it is possible to observe that the data concerning the parameters of total dissolved solids and electrical conductivity measured in the wells are directly correlated due to the ease of electric current transit in salt solutions. The result of the processing of the geophysical acquisitions was divided into four distinct groups, which vary according to the characteristics of the physical parameter of resistivity. With the realization of three distinct field arrangements, Schlumberger, Wenner and Dipole-dipole, the geophysical response is different for each arrangement. In certain lines there are differences between the three sections for the same geological environment, this effect is due to the arrangement ... (Complete abstract click electronic access below) / Mestre
24

O impacto da topologia de conexão de transdutores na obtenção de indicadores de qualidade de energia. / The impact of transducers conection type in power quality measurements.

Alex Almeida Pignatti 19 October 2012 (has links)
A Agência Nacional de Energia Elétrica (ANEEL) deverá estabelecer a regulamentação para distúrbios de qualidade de energia em um futuro próximo. Há ainda questões em aberto sobre os procedimentos de medição e limites máximos para os indicadores de qualidade de energia. Este trabalho aborda uma dessas questões, que é a conexão de transdutores e os impactos nos índices de qualidade de energia associados. Simulações em ATPDraw e campanhas de medição foram realizadas de modo a identificar o comportamento dos indicadores de distorção harmónica sob as duas configurações possíveis de conexão de transdutores: dois equipamentos com ligação entre fases ou três com ligação fase-neutro. Os resultados das simulações e os valores medidos mostram grandes discrepâncias entre ambas as configurações, e as diferenças tornam-se ainda mais significativas com o incremento do desequilíbrio do sistema elétrico. As causas subjacentes deste fenômeno são investigadas e discutidas / The Brazilian electricity regulatory agency (ANEEL) is expected to establish a legal framework for quality disturbances in the near future. There are still some open questions regarding metering procedures and maximum limits for Power Quality indicators. This work addresses one of such issues, namely the connection of the associated transducers and its impact on PQ indexes. Simulations in ATPDraw and on-field measurement campaigns were carried out so as to identify the behavior of harmonic distortion indicators under the two possible transducer configurations: two phase-to-phase or three phase-to-neutral transducers. Simulation results and measured values show large discrepancies between both configurations, and the differences become more significant as the electrical systems unbalance increases. The underlying causes of this phenomenon are investigated and discussed.
25

Estudo de controladores aplicados a inversores para UPS com operação ilhada /

Guillardi Júnior, Hildo. January 2013 (has links)
Orientador: Paulo José Amaral Serni / Banca: Flávio Alessandro Serrão Gonçalves / Banca: José Antenor Pomílio / Resumo: Esta dissertação apresenta o projeto, simulação e ensaio dos protótipos da etapa de saída de uma Fonte de Alimentação Ininterrupta (UPS - Uninterruptible Power Supply) monofásica de tensão igual a 127V e trifásica com tensões 220/127V a 4 fios, ambas de frequência 60Hz e potência nominal igual a 1kVA para uso em operação ilhada. validação da metodologia de projeto foi realizada primeiramente em simulação, e depois, experimentalmente utilizando-se diferentes tipos de cargas tipicamente encontradas em instalações elétricas e diferentes tipos de controladores clássicos: PI (Controlador Proporcional Integral), Ressonante e composição dos dois. Os ensaios experimentais consistiram em duas etapas, regime e transitório, na primeira sendo avaliado o comportamento estático do conversor com parâmetros como valor eficaz (RMS - Root Mean Square) e a Distorção Harmônica Total (THD - Total Harmonic Ditortion) da tensão de saída e, na segunda, o comportamento frente à entrada e saída de cargas, evidenciando a estabilidade do controle. Nas duas etapas foram aplicados procedimentos normatizados de ensaios e os resultados foram comparados com os requisitos das normas aplicáveis a esse tipo de conversor. Como dispositivo de controle utilizou-se um Processador Digital de Sinais (DSP - Digital Signal Processing) de ponto fixo, responsável pelo cálculo do algoritmo de controle e leitura dos sinais de tensões e correntes do inversor; sendo avaliada sua capacidade de processamento frente à manutenção da qualidade e da frequencia do sinal de saída. O projeto aponta a necessidade do controle multimalhas, ou seja, controle da tensão mais corrente, devido à instabilidade criada em sua função de transferência ao alimentar as cargas não resistivas. Também é mostrada, em simulação, a possibilidade de trabalho da interface de potência do protótipo em outros propósitos: Retificar com Alto Fator de Potência (para recarga... / Abstract: This dissertation presents the design, simulation and testing of the prototype os the stage of output of a UPS (Uninterruptible Power Supply) single-phase with voltage equal to 127V and three-phase with voltage equal to 127V and three-phase with voltage equal to 220/127V four-wired, both with 60Hz and nominal power of 1kVA to use in inslanded mode. The validation of the methodology of the project was realized first in simulation, and subsequently, experimentally using different kinds different kinds of loads typically found in electrical installations and, different kinds of classical controllers: PI (Proportional Integrative Controller), Resonant and composition of both. The testing has consisted of 2 stages: steady state and transitory state, in the first stage, it has been measured the RMS (Root Mean Square) value and THD (Total Harmonic Distortion) of the voltage of the output and, in the second stage, the behavior in relation to the loads step in and step out, highlighting the stability of the control. The standardized procedures of the test have been applied in the two stage and the results were compared to the requirements of the applicable standards to this kind of power converter. It has been used a fixed point DSP (Digital Signal Processing) as a device of control, which was responsible for the calculation of the control algorithm and for the signal sampling of voltages and currents of the inverter; being measured its processing capacity in relation to the conservation of power quality and the signal frequency of output. The project has indicated the necessary of the multi-loop control, i.e, voltage plus current controller, due to the instability generated in its transfer function when supplying non-resistive loads. It has been also demonstrated in simulation, the possibility of the power interface works in others functionalities: Rectifier with Power Factor Correction (to battery recharge), Current Source Inverter... / Mestre
26

Retificador multipulso com baixa distorção de corrente na rede e isolamento em alta frequência através de estágio SEPIC /

Lourenço, Angelo César January 2016 (has links)
Orientador: Falcondes José Mendes de Seixas / Resumo: A utilização de conversores com baixa distorção harmônica na corrente de entrada melhora significativamente o fator de potência de equipamentos e instalações elétricas. Este trabalho apresenta a proposta de desenvolvimento de um conversor multipulso com estágio CC-CC SEPIC, que apresenta baixa distorção na corrente de entrada, regulação da tensão na saída, podendo ainda apresentar isolamento em alta frequência. Propõe-se a utilização do conversor proposto em aplicações industriais em inversores para acionamento de máquinas elétricas de corrente alternada, em substituição aos retificadores convencionais, técnica conhecida como retrofit, em barramentos CC regulados, fontes de tensão CC, entre outras aplicações. O conversor é baseado em um autotransformador não isolado de 18 pulsos, que disponibiliza três saídas trifásicas independentes e apresenta reduzido peso e volume quando comparados com os tradicionais transformadores isolados. Este conversor já apresenta significativa melhoria no fator de potência, porém não possibilita a regulação da tensão na saída, que dependerá unicamente da tensão de entrada, estando sujeita às variações que nela ocorram. As saídas independentes, após retificação, devem ser conectadas para poder alimentar a carga. A forma mais comum de possibilitar essa conexão é utilizando elementos magnéticos adicionais, chamados de transformadores interfase (IPTs). A utilização de conversores CC-CC é outra forma de realizar a conexão, resultando em um estágio CC-C... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Converters with low harmonic distortion of input current can improve significantly the power factor at electrical equipment and plants. This work proposes the development of a multipulse converter with DC-DC SEPIC stage, with low distortion in the input current, and may also provide high frequency isolation. It could be used in industrial applications to replace conventional rectifiers in Adjustable Speed Drives (ASDs), a technique known as retrofit. It can be used also in regulated DC bus, DC voltage power supply, among other applications. The converter is based on a non-isolated 18-pulse autotransformer that provides three independent three-phase outputs and has reduced weight and size. The autotransformer improves the power factor, but does not allow the regulation of the load voltage output. The independent outputs must be connected to the load. The most common way of providing this connection is by using additional magnetic elements, called interphase transformer (IPTs). The use of DC-DC converters is another way to perform the outputs connections, resulting in a DC-DC stage that control the voltage and current, thus enabling parallel connect loads. In this work, the SEPIC converter was selected, because it can be used with few modifications to the original structure. SEPIC converter can easily be isolated, allowing the use of multipulse converters in applications that require isolation between power supply and load. Prototypes with isolated and non-isolated SEPIC conver... (Complete abstract click electronic access below) / Doutor
27

Uso de pseudomedidas em estimador de estados para cálculo de distorção harmônica em sistemas elétricos

Pulz, Lucas Tupi Caldas January 2017 (has links)
A maior presença de correntes harmônicas no sistema de distribuição, principalmente devido à geração distribuída, tem chamado atenção sobre suas possíveis consequências. O trabalho apresenta um método para a avaliação de harmônicas em um sistema elétrico através de um estimador de estados. A proposta é um método de supervisão da rede de distribuição utilizando o menor número de medidores possível. Isso foi feito identificando topologias de rede que viabilizam o uso de pseudomedidas no lugar de medidores. O método é aplicado a um estudo de caso baseado no modelo IEEE 13 barras e os resultados do estimador de estados foram comparados a uma simulação. Também é feita uma análise de sensibilidade do código, observando os resultados quando se adicionam erros sobre as medidas e sobre os parâmetros das linhas do sistema. / The growth of harmonic currents in distribution system, mainly due the distributed generation, is calling attention of the specialists to its possible consequences. This work presents a method to assessment of harmonics in an electric power system through a state estimator. The proposal is a method to monitor the distribution network using as few measurement devices as possible. It was performed identifying network topologies where a pseudomeasurement can replace a measurement device. The method was applied to a study case based on the IEEE 13 buses model and its results were compared to a simulation. A sensitivity analysis of the code also was performed, errors were added to measurements and lines parameters to assess the errors in the state estimator results.
28

Determinação do momento crítico de flambagem lateral com distorção em vigas mistas contínuas de aço e concreto com perfis de alma senoidal

Oliveira, Janaina Pena Soares de 09 May 2014 (has links)
Submitted by Maykon Nascimento (maykon.albani@hotmail.com) on 2015-07-27T17:02:11Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Determinação do momento crítico de flambagem lateral com distorção em vigas mistas contínuas de aço e concreto com perfis de alma senoidal.pdf: 9284566 bytes, checksum: e957b385d314e7f881f9d416a404996b (MD5) / Approved for entry into archive by Patricia Barros (patricia.barros@ufes.br) on 2015-08-11T16:28:37Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Determinação do momento crítico de flambagem lateral com distorção em vigas mistas contínuas de aço e concreto com perfis de alma senoidal.pdf: 9284566 bytes, checksum: e957b385d314e7f881f9d416a404996b (MD5) / Made available in DSpace on 2015-08-11T16:28:37Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Determinação do momento crítico de flambagem lateral com distorção em vigas mistas contínuas de aço e concreto com perfis de alma senoidal.pdf: 9284566 bytes, checksum: e957b385d314e7f881f9d416a404996b (MD5) Previous issue date: 2014 / As vigas mistas de aço e concreto estão sendo largamente utilizadas em construções de edifícios e pontes. Ao se combinar o aço com o concreto obtêm-se estruturas mais econômicas, uma vez que se tira proveito das melhores características de cada material. Nas regiões de momento negativo de uma viga mista contínua, a mesa inferior e parte da alma estão comprimidas, se a alma do perfil não tiver rigidez suficiente para evitar a flexão lateral, ela distorcerá gerando um deslocamento lateral e um giro na mesa comprimida, caracterizando um modo de flambagem denominado flambagem lateral com distorção (FLD). O procedimento de verificação à FLD da EN 1994-1-1:2004 originou o método de cálculo da ABNT NBR 8800:2008, entretanto a EN 1994-1-1:2004 não fornece expressão para o cálculo do momento crítico elástico, enquanto a ABNT NBR 8800:2008 prescreve uma formulação proposta por Roik, Hanswille e Kina (1990) desenvolvida para vigas mistas com perfis de alma plana. Embora as normas prescrevam um método de verificação à FLD para vigas mistas com perfis de alma plana, poucos estudos têm sido feitos sobre esse estado-limite. Além disso, tanto a ABNT NBR 8800:2008 quanto as normas internacionais não abordam perfis de alma senoidal. Neste trabalho, foram implementadas análises de flambagem elástica, com auxílio do software ANSYS 14.0 (2011), em modelos de elementos finitos que retratem o comportamento à FLD de vigas mistas de aço e concreto com perfis de alma plana e senoidal. Os modelos numéricos foram constituídos pelo perfil de aço, por uma mola rotacional que restringe parcialmente o giro da mesa superior e uma restrição ao deslocamento lateral, ao longo de todo o comprimento da viga. Os resultados numéricos são comparados com os obtidos pelas formulações de Roik, Hanswille e Kina (1990) e de Hanswille (2002), adaptadas para levar em consideração a corrugação da alma do perfil de aço. Para avaliação das formulações supracitadas e da consistência da modelagem numérica adotada, o momento crítico elástico foi determinado para vigas mistas com perfis de aço de alma plana. Como resultado, um método para o cálculo do momento crítico elástico de vigas mistas de alma senoidal é proposto. / The composite steel-concrete beams have been widely used in the constructions of buildings and bridges. The interaction between the steel and concrete leads to economic structures, because it is possible to take out the best of what each material can offer. In the negative moment region of continuous composite beams, the bottom flange and part of the web are compression. If the web of the steel profile doesn’t have enough stiffness to avoid the lateral flexural, the flange will displaced laterally. This instability is known as distortional lateral buckling. The procedure for verification the distortional lateral buckling of EN 1994-1-1:2004 originated the calculation method of ABNT NBR 8800:2008. But the EN 1994-1-1:2004 do not offer the expression to determine the elastic critical moment while the ABNT NBR 8800:2008 prescribes a formulation proposed by Roik, Hanswille e Kina (1990) developed for composite beams with plane web profiles. Even though the standards prescribe the verification of distortional lateral buckling for the composite beams with plane web profiles, few studies have been made about this limit state. Moreover, the ABNT NBR 8800:2008 and international standards do not approach about sinusoidal-web profiles. In this paper, was implemented elastic buckling analysis in finite element models using the software ANSYS 14.0 (2011). These models describe the behavior of distortional lateral buckling of composite beams with plane web and sinusoidalweb profiles. The numeric models were composed by steel profile, rotational spring and lateral restraint, both applied along the beam span to restrain the steel top flange. The numerical results are compared with the formulation of Roik, Hanswille e Kina (1990) and Hanswille (2002), adapted to consider the corrugation of the sinusoidal-web profile. To evaluate the formulations and consistency of the numerical model, the elastic critical moment was determined for composite beams with plane web profile. Finally, a procedure for determining elastic critical moment of composite beams with sinusoidal-web profile is proposed.
29

Transtorno de ansiedade social e insatisfação com a imagem corporal em estudantes de medicina: prevalência e fatores associados / Social Anxiety Disorder and Body Image Disatisfaction in Medical Students: Prevalence and Associated Factors

Regis, Jacqueline Maria de Oliveira [UNESP] 17 August 2015 (has links) (PDF)
Made available in DSpace on 2016-01-13T13:26:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-08-17. Added 1 bitstream(s) on 2016-01-13T13:32:14Z : No. of bitstreams: 1 000854658.pdf: 1674345 bytes, checksum: f11bd92734e04030411cea431e54abf6 (MD5) / Introdução: Estudos sugerem que a prevalência de Fobia Social (FS) ou Transtorno de Ansiedade Social (TAS) em estudantes universitários é alta, assim como a prevalência de insatisfação com a imagem corporal (IIC). As manifestações clínicas destes quadros podem causar muito sofrimento e interferir negativamente na vida dos estudantes, tanto em suas relações interpessoais quanto no seu desempenho acadêmico. Objetivos: Estimar a prevalência e avaliar a gravidade de manifestações de TAS e de IIC em estudantes de medicina de uma universidade pública do Estado de São Paulo, assim como os fatores associados a estes dois desfechos. Método: Estudo de corte transversal avaliou 479 estudantes do primeiro ao sexto ano do curso médico da Faculdade de Medicina de Botucatu - UNESP (taxa de resposta: 88,1%) por meio dos seguintes instrumentos de autopreenchimento: Questionário sobre características sociodemográficas e aspectos de vida acadêmica dos alunos, Inventário de Fobia Social - Social Phobia Inventory (SPIN), Questionário de Insatisfação com a Imagem Corporal - Body Shape Questionnaire (BSQ) e Inventário de Depressão de Beck - Beck Depression Inventory (BDI). Foi feita análise estatística descritiva, seguida de análise bivariada entre os desfechos de interesse (provável TAS e IIC) e variáveis explanatórias, pelo teste de qui-quadrado para variáveis categoriais e de Mann Whitney para variáveis quantitativas. O tamanho de efeito das associações foi descrito como razão de chances (odds ratios) com intervalos de confiança (IC) de 95% para variáveis categóricas e D de Cohen para variáveis quantitativas. Por fim, foram construídos três modelos de regressão logística (para provável TAS, IIC e os dois desfechos associados), incluindo as variáveis explanatórias que foram significativas (p < 0,05) na análise bivariada, para controle de confundidores e obtenção de odds ratios (OR) e IC... / Introduction: Previous studies described high prevalence rates of Social Anxiety Disorder (SAD) (or Social Phobia) and of body image dissatisfaction (BID) in college students. Manifestations of these clinical problems may cause much suffering and negatively interfere in the students' life, both in their interpersonal relationships and academic performance. Objectives: To estimate the prevalence and severity of SAD and BID manifestations in medical students of a public university in São Paulo state, Brazil, as well as to investigate the characteristics associated with these outcomes. Method: A cross-sectional study with 479 students from the first to the sixth year of the medical course at Botucatu Medical School - UNESP (response rate: 88.1%), using the following assessment instruments: a questionnaire to obtain data on demographics and social and academic life,, the Social Phobia Inventory (SPIN), the Body Shape Questionnaire (BSQ), and the Beck Depression Inventory (BDI). A descriptive analysis was conducted, followed by a bivariate analysis between the outcomes (probable SAD and BID) and all explanatory variables, using the chi - square test for categorical variables and the Mann-Whitney test for quantitative variables. The effect sizes of the associations were described as odds ratios (OR) with 95% confidence intervals (CI) for categorical variables, and Cohen's D for quantitative variables. Then, three logistic regression models (for probable SAD, BID and both outcomes combined) were built, including, in each of them, the explanatory variables that were significant (p<0.05) in the bivariate analysis to control for confounders and obtain adjusted ORs. Results: The median age of the students (58.7% female, 99.0% single) was 22.5 years (SD±2.6). The prevalence of probable SAD (SPIN ≥ 19) was 36.3% (95%CI 32.0-40.6), and some BID (BSQ > 81) was found in 34.7% (95%CI 30.4-38.9) of the students. Relevant depressive symptoms ...
30

Estudo de controladores aplicados a inversores para UPS com operação ilhada

Guillardi Júnior, Hildo [UNESP] 18 December 2013 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:45Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-12-18Bitstream added on 2014-12-02T11:21:42Z : No. of bitstreams: 1 000746210.pdf: 6245568 bytes, checksum: bdf740a9e0ec90838ebde8f31ea0e16e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Esta dissertação apresenta o projeto, simulação e ensaio dos protótipos da etapa de saída de uma Fonte de Alimentação Ininterrupta (UPS - Uninterruptible Power Supply) monofásica de tensão igual a 127V e trifásica com tensões 220/127V a 4 fios, ambas de frequência 60Hz e potência nominal igual a 1kVA para uso em operação ilhada. validação da metodologia de projeto foi realizada primeiramente em simulação, e depois, experimentalmente utilizando-se diferentes tipos de cargas tipicamente encontradas em instalações elétricas e diferentes tipos de controladores clássicos: PI (Controlador Proporcional Integral), Ressonante e composição dos dois. Os ensaios experimentais consistiram em duas etapas, regime e transitório, na primeira sendo avaliado o comportamento estático do conversor com parâmetros como valor eficaz (RMS - Root Mean Square) e a Distorção Harmônica Total (THD - Total Harmonic Ditortion) da tensão de saída e, na segunda, o comportamento frente à entrada e saída de cargas, evidenciando a estabilidade do controle. Nas duas etapas foram aplicados procedimentos normatizados de ensaios e os resultados foram comparados com os requisitos das normas aplicáveis a esse tipo de conversor. Como dispositivo de controle utilizou-se um Processador Digital de Sinais (DSP - Digital Signal Processing) de ponto fixo, responsável pelo cálculo do algoritmo de controle e leitura dos sinais de tensões e correntes do inversor; sendo avaliada sua capacidade de processamento frente à manutenção da qualidade e da frequencia do sinal de saída. O projeto aponta a necessidade do controle multimalhas, ou seja, controle da tensão mais corrente, devido à instabilidade criada em sua função de transferência ao alimentar as cargas não resistivas. Também é mostrada, em simulação, a possibilidade de trabalho da interface de potência do protótipo em outros propósitos: Retificar com Alto Fator de Potência (para recarga... / This dissertation presents the design, simulation and testing of the prototype os the stage of output of a UPS (Uninterruptible Power Supply) single-phase with voltage equal to 127V and three-phase with voltage equal to 127V and three-phase with voltage equal to 220/127V four-wired, both with 60Hz and nominal power of 1kVA to use in inslanded mode. The validation of the methodology of the project was realized first in simulation, and subsequently, experimentally using different kinds different kinds of loads typically found in electrical installations and, different kinds of classical controllers: PI (Proportional Integrative Controller), Resonant and composition of both. The testing has consisted of 2 stages: steady state and transitory state, in the first stage, it has been measured the RMS (Root Mean Square) value and THD (Total Harmonic Distortion) of the voltage of the output and, in the second stage, the behavior in relation to the loads step in and step out, highlighting the stability of the control. The standardized procedures of the test have been applied in the two stage and the results were compared to the requirements of the applicable standards to this kind of power converter. It has been used a fixed point DSP (Digital Signal Processing) as a device of control, which was responsible for the calculation of the control algorithm and for the signal sampling of voltages and currents of the inverter; being measured its processing capacity in relation to the conservation of power quality and the signal frequency of output. The project has indicated the necessary of the multi-loop control, i.e, voltage plus current controller, due to the instability generated in its transfer function when supplying non-resistive loads. It has been also demonstrated in simulation, the possibility of the power interface works in others functionalities: Rectifier with Power Factor Correction (to battery recharge), Current Source Inverter...

Page generated in 0.033 seconds