• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 330
  • 190
  • 18
  • 10
  • 9
  • 7
  • 6
  • 4
  • 3
  • 1
  • 1
  • Tagged with
  • 647
  • 647
  • 288
  • 282
  • 259
  • 226
  • 198
  • 160
  • 148
  • 141
  • 133
  • 124
  • 122
  • 117
  • 110
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Desafios e perspectivas da energia solar fotovoltaica no Brasil : geração distribuída vs geração centralizada /

Pereira, Narlon Xavier January 2019 (has links)
Orientador: Antonio Cesar Germano Martins / Resumo: Nos últimos anos a energia solar fotovoltaica tem mostrado forte crescimento dentre as fontes renováveis em várias partes do mundo. O Brasil vem discutindo mais intensamente desde 2012 formas de incentivo para a inserção da energia solar fotovoltaica bem como a adequação do modelo centralizado e distribuído na matriz elétrica nacional. Para contribuir com esta discussão, neste trabalho foi realizado um levantamanto de informações a respeito destes dois modelos a partir de consultas à livros, artigos, periódicos, sites e reportagens. Os resultados dessas pesquisas foram agrupados e consolidados em gráficos, tabelas e quadros que permitiram a avaliação das perspectivas da energia solar fotovoltaica no Brasil, identificando os principais aspectos dos dois modelos de geração, levando-se em consideração suas características distintas e relacionadas à geração, distribuição e consumo salientando-se as vantagens e desvantagens segundo critérios ambientais, econômicos; sociais e técnicos. As análises dos materiais constituintes da pesquisa denotam que, no caso do Brasil, os dois modelos progridem de maneira complementar, porém necessitam de políticas governamentais mais eficazes para as suas implementações de forma ampla e significativa na matriz energética nacional. / Mestre
102

Utilização de unidades de microgeração fotovoltaica para regulação centralizada de tensão

Godoy, Lívia Lisandro Judice January 2017 (has links)
A Geração Distribuída no Brasil tem crescido ao longo dos anos, especialmente na fonte fotovoltaica e na categoria que a ANEEL denomina microgeração distribuída, que são centrais geradoras de energia elétrica com potência instalada menor ou igual a 75 kW e conectada na rede de distribuição por meio de instalações de unidades consumidoras. Apesar dos problemas tradicionais que podem ocorrer com a inserção em larga escala, como maiores perdas e desvios de tensão, as placas fotovoltaicas, conectadas à rede de distribuição por meio de um inversor, trazem a possibilidade de controlar a tensão no ponto de conexão, manipulando-se o fator de potência de saída do inversor, controlando a potência reativa. Neste contexto, considerando o uso dos inversores inteligentes com possibilidade de envio de sinal remotamente ao operador e a possibilidade de criação de Centros de Despacho de Geração Distribuída (CDGD), este trabalho tem por objetivo propor uma metodologia de regulação de tensão centralizada utilizando unidades de microgeração fotovoltaicas, em redes de distribuição com larga inserção. A metodologia proposta utiliza o conceito de despacho de potência reativa e fluxo de potência reativa ótimo, por meio de uma abordagem centralizada da rede, utilizando-se o software OpenDSS e MatLab, equipado com Algoritmo Genético (AG) para solucionar o problema de otimização. Para avaliar o desempenho do modelo, foram feitos estudos de caso no sistema IEEE 123 barras e em uma rede real em Alegrete. Os resultados obtidos validam a abordagem proposta, demonstra a aplicabilidade e limitações em casos reais. / The distributed generation in Brazil has increased in the past years, specially in photovoltaic power generation, at the category that Brazilian Electric Regulator ANEEL classifies as "distributed micro-generation", i.e., generation units in which the active power capacity is equal or bellow 75kW and conected on distribution network by the consumers. Despite the traditional problems that might occur due to high penetration of the units, e.g., higher losses and voltage sags and swells, they are conected to the network through an inverter that can be controlled in order to provide or consume reactive power, providing voltage regulation. In that context, considering the use of intelligent inverters that can be remotely operated by a centralized utility operator, this work aims to propose a centralized voltage regulation methodology using distributed micro-generation in distribution networks. The proposed methodology uses the concept of reactive power dispatch and optimal power flow, from a centralized view of the network, using the software MatLab and OpenDSS with Genetic Algorithm to solve the optimization problem. To evaluate the model, simulations were performed with the IEEE 123 bus system and with a real distribution network from the Alegrete city, in the Brazilian state of Rio Grande do Sul. The results show the proposed is valid, despite some limitations on real cases.
103

Analyses of Energy Infrastructure Serving a Dense Urban Area: Opportunities and Challenges for Wind Power, Building Systems and Distributed Generation

Waite, Michael B. January 2016 (has links)
This dissertation describes methodologies for evaluating a set of anticipated and recommended energy infrastructure changes essential to achieving deep greenhouse gas emissions reductions in a dense urban area: Deep penetration of grid-connected wind power, widespread adoption of electric heat pumps, multiple potential services from extensive deployment of distributed generation, and increasing focus on auxiliary energy in heating and cooling systems as cities continue to grow in population and height. The focus of the research presented here was New York City and the surrounding New York State electricity supply infrastructure. After developing a wind power model based on an NREL model wind data set, a linear program model showed that after passing a low-curtailment threshold of 10 GW, energy-related wind power curtailment is driven largely by continuous operation of baseload generation and misalignment of winter wind power peaks and existing summer electricity demand peaks. Separate analyses showed the potential for increase wind-generated electricity utilization through increased use of heat pumps in New York City. A suite of models was developed to assess the zonal effects in New York City of deep statewide penetration of wind power and widespread adoption of electric heat pumps in New York City. New York City was found to have highly fluctuating net loads in deep wind penetration scenarios. Further, with large amounts of existing space heating demand replaced by heat pumps, the increased winter electricity demand peaks occurred infrequently enough that the additional generation capacity required to meet those loads would have a capacity factor well less than 1%. Small-scale, natural gas-fueled internal combustion engines deployed as distributed generation were shown to improve the ability of the system to respond to load fluctuations, to be a more economical option than new large centralized generators at the low capacity factor, and to reduce overall system gas usage due to mitigating part-load effects and startup fuel requirements. This distributed generation, which could in reality also include combined heat and power systems as well as battery storage standing alone, connected to rooftop solar or in electric vehicles, also has potential system resilience benefits. The last research effort described here included long-term monitoring of a high-rise mixed use building’s hydronic system before and after a retrofit of hydraulic equipment. Significant annual reductions of 40% energy usage for pumping were computed, primarily due to part-load flow control effects. Analysis of the monitoring data, as well as computations related to theoretical performance of hydraulic networks, showed that this approach also has potential to reduce peak loads, particularly in high-rise buildings.
104

Impact of hybrid distributed generation allocation on short circuit currents in distribution systems

Afifi, Sara Nader January 2017 (has links)
The rapid development in renewable generation technologies and flexible distribution networks requires current infrastructure to be modified and developed to adapt high penetration levels of distributed generation. Existing distribution networks were not initially designed and anticipated to accommodate generators on large scale. Short circuit studies ensure the effectiveness of protection equipment settings and coordination is maintained in case of short circuit, despite any additional distributed generation is connected to the distribution network. This research aims to study and compare the different network fault situations for wind energy systems with induction generators, photovoltaic energy systems, and diesel generators connected to distribution networks. The simulation study will be conducted on the existing IEEE case study systems including 13 bus and 30 bus distribution test systems, using ETAP software. Short circuit analysis will be performed twice to include the ANSI/IEEE and the IEC methods for short circuit currents calculation. Simulated results showed that the wind energy systems have significant impact on the short circuit currents, whereas the photovoltaic energy systems are found to have inconsequential effect. The most moderate solution is found to be a distributed generation mix.
105

Uma avaliaÃÃo de viabilidade financeira no uso da energia solar fotovoltaica apoiada pela resoluÃÃo ANEEL 482/2012 sobre geraÃÃo distribuÃda no setor elÃtrico do Brasil. / An assessment of financial viability in the use of photovoltaic solar energy supported by ANEEL Resolution 482/2012 on distributed generation in the electricity sector in Brazil.

Francisco Ivanhoel Aguiar de Carvalho 03 July 2014 (has links)
nÃo hà / A presente dissertaÃÃo analisa a viabilidade financeira de implantaÃÃo de projetos de geraÃÃo de energia fotovoltaica na perspectiva do consumidor. AtravÃs da ResoluÃÃo Normativa ANEEL 482/2012, que estabelece as condiÃÃes gerais para o acesso de microgeraÃÃo e minigeraÃÃo conferidas aos sistemas de distribuiÃÃo de energia elÃtrica por meio do mÃtodo de compensaÃÃo do referido produto energÃtico. Para tanto, a pesquisa foi realizada sobre os Sistemas Fotovoltaicos Conectados à Rede â SFCR, atravÃs da construÃÃo de dois cenÃrios: (i) proposta de auto-suficiÃncia em geraÃÃo fotovoltaica, pagando o custo de disponibilidade da distribuidora e os impostos devidos e (ii) onde o intuito à utilizar a energia fotovoltaica de forma a anular o âhorÃrio de solâ na geraÃÃo alternativa, tambÃm arcando com custos de disponibilidade e impostos devidos. As simulaÃÃes utilizaram o painel KD140SX-UPU, por seu custo benefÃcio e vida Ãtil, tomando por base a tarifa do consumidor residencial B1 homologada pela ANEEL para a COELCE atravÃs da ResoluÃÃo HomologatÃria 1.711/2014, que à de 0,35922 R$/kWh. O resultado da anÃlise econÃmica para o consumidor mostrou-se atrativa apenas no cenÃrio (ii) uma vez que a Taxa Interna de Retorno foi maior que a Taxa MÃnima de Atratividade e o tempo mÃdio de Payback calculado de 9,92 anos. Acerca de efeitos para a concessionÃria de energia, as discussÃes indicaram que a adesÃo de potenciais consumidores, provavelmente da ultima faixa de consumo (maior que 220 kWh) poderia ocasionar impactos econÃmicos na Receita Operacional Liquida, o que pode ser objeto de pesquisas futuras, mas que a rede elÃtrica seria afetada de forma positiva, uma vez que a carga descentralizada traria uma reduÃÃo de perdas, estabilidade de tensÃo de fornecimento e a possibilidade de postergaÃÃo dos investimentos na ampliaÃÃo da rede de distribuiÃÃo. A pesquisa conclui que a implementaÃÃo plena da ResoluÃÃo ANEEL 482/2012 torna-se viÃvel com modificaÃÃes regulatÃrias, regras claras no aspecto tÃcnico, maior participaÃÃo governamental na concessÃo de incentivos financeiros e em linhas especiais de financiamento. Por estas implementaÃÃes, benefÃcios tarifÃrios poderiam refletir de forma positiva para o consumidor cativo, uma vez a energia excedente injetada na rede, acarretaria um melhor planejamento de engenharia das empresas, dimensionando melhor os equipamentos elÃtricos, otimizando, assim, os Ãndices de aproveitamento destes bens, aumentando sua vida Ãtil e contribuindo para a modicidade tarifÃria. / This dissertation analyzes the financial viability deployment of photovoltaic power generation projects from a consumer perspective. By ANEEL Normative Resolution 482/2012, which establishes the general conditions for micro-generation access and minigeneration granted to electricity distribution systems via the compensation method of that energy product. Therefore, the survey was conducted on Photovoltaic Systems Connected to Network - SFCR through the construction of two scenarios: (i) proposal for self-sufficiency in photovoltaic generation, paying the cost of distribution and availability taxes due and (ii ) where the aim is to use photovoltaics in order to cancel the "sun hours" in alternative generation, also bearing availability and costs owed taxes. The simulations used the KD140SX-UPU panel for his money and life, based on the residential user tariff B1 approved by ANEEL for COELCE through Ratifying Resolution 1,711 / 2014, which is US $ 0.35922 / kWh . The outcome of the economic analysis for the consumer proved to be attractive only in the scenario (ii) since the internal rate of return was higher than the Minimum Rate of Attractiveness and the average time calculated Payback 9.92 years. About effects on power utility, the discussions indicated that the accession of potential consumers, probably the last track consumption (greater than 220 kWh) could cause economic impacts in Net Operating Revenue, which can be further research object, but that the grid would be affected in a positive way, since the decentralized load would bring a reduction of losses, supply voltage stability and the possibility of postponement of investments in the expansion of the distribution network. The research concludes that the full implementation of ANEEL Resolution 482/2012 becomes feasible with regulatory changes, clear rules on the technical side, greater government involvement in financial incentives and special lines of credit. For these implementations, tariff benefits could reflect positively to the captive consumers, as surplus energy injected into the network, would lead to better planning engineering companies, better sizing electrical equipment, thus optimizing the utilization rates of these goods , increasing its life and contributing to the low tariffs
106

Proteção adaptativa anti-ilhamento de geradores síncronos distribuídos / Adaptive anti-islanding protection of distributed synchronous generators

Sérgio Oliveira Pitombo 02 July 2010 (has links)
A expansão de geração distribuída nos sistemas de distribuição e de subtransmissão de energia elétrica em todo o mundo tem sua origem na reestruturação do setor elétrico, na necessidade de aproveitamento de diferentes fontes primárias de energia, nos avanços tecnológicos, nos incentivos governamentais e na maior conscientização sobre conservação ambiental. Com tal expansão, surge a necessidade de avaliar os impactos dessa forma de geração na operação das redes elétricas, principalmente das redes de distribuição, as quais foram inicialmente projetadas para operar considerando apenas a subestação de distribuição como fonte de energia. Entre esses impactos, um importante item a co0nsiderar é a detecção de ilhamento. Tal ocorrência é altamente indesejada pelas concessionárias distribuidoras de energia elétrica as quais estabelecem que os proprietários de geradores distribuídos devem instalar um sistema de proteção capaz de detectar ilhamentos. Dentre os métodos empregados para detecção de ilhamento os mais comuns para este propósito são os relés baseados em medidas de freqüência (relé de sub/sobrefreqüência, relé de taxa de variação de freqüência). Tais dispositivos são fortemente dependentes do desbalanço de potência ativa na rede ilhada e podem falhar caso esses desbalanços sejam pequenos. Ressalta-se que o comportamento variável da carga em sistemas de distribuição e a possibilidade de formação de diversas ilhas podem originar diferentes níveis de desbalanço de potência ativa e reativa. Conseqüentemente, pode haver vários cenários de operação em que os relés previamente citados falharão em detectar ilhamento. Neste contexto, esta dissertação de Mestrado propõe metodologias de proteção adaptativa anti-ilhamento aplicadas a relés baseados em medidas de freqüência, que visem a proteção do sistema elétrico e do gerador distribuído na maioria das condições de desbalanço de potência ativa e reativa que possam ocorrer na rede elétrica. Os geradores distribuídos a serem analisados são do tipo síncrono devido a sua grande utilização em pequenas centrais hidroelétricas e térmicas. São propostas duas metodologias: uma baseada em simulações dinâmicas e outra baseada em fórmulas analíticas. Os resultados obtidos foram satisfatórios para vários cenários de operação de um gerador distribuído conectado em uma rede de distribuição. Além disso, as vantagens e limitações de cada método são apresentadas e discutidas. / Distributed generation expansion worldwide has been caused by the de-regulamentation of the electricity sector, by the necessity to explore different energy resources, by technological advances, by government incentives and by environmental concerns associated with energy production. Such expansion brings the necessity to assess he impacts caused by distributed generators on the distribution systems, which were designed to operate considering the utility substation as the only power source. Among these impacts, on that deserves major attention is islanding detection. Utilities recommend that distributed generators\' owners provide efficient anti-islanding protection installed at the point of common coupling between the generator and the grid. Common anti-islanding protection schemes are composed by frequency-based relays (standard frequency relay and/or rate of change of frequency relay). These devices are strongly dependent on the active power imbalance in the islanded system and they can fail to detect an islanding condition if such power imbalance is small. Therefore, it is worth pointing that the variable power consumption of the distribution system\'s loads and the possibility of creating several energized islands can originate different power imbalance levels. Consequently, there may be various operating scenarios in which the frequency-based relays will fail to detect islanding. In this context, this work proposes adaptive methods to adjust frequency-based relays in order to provide effective anti-islanding protection considering different power imbalance levels. Synchronous generators are studied, since their wide application in distributed generation plants, such as small hydro and thermal power plants. Two methods are proposed: one is a simulation-based method and the other is based on analytical formulas. Both methods presented good results considering all the operating scenarios tested with a distributed generator connected to a distribution system. Furthermore, their advantages and limitations are presented and discussed.
107

Detecção de ilhamento de geradores síncronos distribuídos por correlações da mineração complexa de dados / Islanding detection of distributed synchronous generators by complex data-mining correlations

Eduardo Augusto Pereira Gomes 31 August 2016 (has links)
Um dos principais problemas que podem ocorrer em sistemas de distribuição ou de subtransmissão de energia elétrica com geração distribuída (GD) é o ilhamento. O ilhamento ocorre quando um ou mais geradores distribuídos alimentam uma porção do sistema que se encontra eletricamente isolada do restante do sistema elétrico. Logo, geradores distribuídos têm de ser equipados com esquema de proteção anti-ilhamento, pois a operação ilhada pode colocar em risco a segurança das pessoas e equipamentos e pode deteriorar a qualidade da energia elétrica suprida aos consumidores locais. Este trabalho está inserido no contexto de proteção de sistemas elétricos de distribuição com GD e propõe uma nova técnica passiva-inteligente de proteção anti-ilhamento para geradores síncronos distribuídos. O método proposto utiliza a mineração de dados do Data Mining of Code Repositories (DAMICORE), o qual possui grandes potencialidades para descobrir correlações em dados complexos. Para realizar essa tarefa, três algoritmos são executados em sequência. São eles: o Normalized Compression Distance (NCD) para calcular a matriz de distância do conjunto de dados; o Neighbor-Joining (NJ) para construir as árvores filogenéticas; e por fim o Fast Newman (FN) para buscar grupos na árvore filogenética nos quais os dados apresentam alto grau de independência. O método de detecção de ilhamento nesta dissertação utiliza 10 características importantes dos sinais de tensão e corrente trifásicas no ponto de acoplamento comum (PAC). Essas 10 características são utilizadas como entrada ao DAMICORE para formular um algoritmo baseado em mineração de dados capaz de detectar ilhamento e de diferenciá-los de outros tipos de distúrbios. Os resultados mostram que o método identifica o ilhamento corretamente, detectando-o rapidamente, especialmente nos casos em que a detecção do ilhamento por relés baseados em medidas de frequência falha ou é lenta. / One of the main issues that can occur into distribution power systems with distributed generation is islanding. Islanding occurs when one or more distributed generators feed a portion of the distribution system that becomes electrically isolated from the rest of the power system. Thus, distributed generators have to be equipped with anti-islanding protection schemes, because the islanded operation may put at risk the safety of people and the equipment. It can also deteriorate the power quality supplied to local consumers. This work is in the context of the protection schemes for distribution power systems with distributed generation and it proposes a new intelligent passive anti-islanding protection scheme for distributed synchronous generators. The scheme is based on the Data Mining of Code Repositories (DAMICORE), which finds the similarity within complex data sets. This task is performed by computing the following algorithms, in sequence: the Normalized Compression Distance (NCD) to calculate a distance matrix among the data sets; the Neighbor-Joining (NJ) to build the phylogenetic trees; and the Fast Newman (FN) to find clusters with high degree of independence by using the phylogenetic trees. The proposed method comprises the extraction of 10 important features of the three-phase voltages and currents measured at the point of common coupling of the distributed generator. These 10 features are then used as input to the DAMICORE in order to formulate a data mining-based algorithm capable of detecting islanding and of distinguishing it from other disturbances. The results show that the method identifies the islanding correctly, detecting it quickly, especially where the detection of islanding by frequency-based relays are slow.
108

Análise da influência de motores de indução sobre o comportamento dinâmico de um DFIG conectado a um sistema de distribuição / Analysis of the influence of induction motors under the dynamic behavior of a DFIG connected to a distribution system

Rafael Cruz Borges 24 March 2017 (has links)
Com o advento da geração distribuída, a operação do sistema de distribuição tem se modificado. Características dinâmicas que antes eram observadas somente no sistema de transmissão agora também podem estar presentes em sistemas de distribuição, como por exemplo, problemas relacionados às oscilações eletromecânicas. Devido à perspectiva de crescimento de conexões de geradores eólicos, fica evidente a possibilidade do aumento na produção de energia elétrica através de geradores assíncronos distribuídos. No sistema de distribuição estão presentes vários tipos de cargas, sendo uma das mais representativas, as cargas do tipo motor de indução. Este tipo de carga, na ocorrência de curto-circuitos no sistema pode provocar atraso na recuperação da tensão do sistema, conhecido como problema Fault Induced Delayed Voltage Recovery (FIDVR). Depois que a falta é eliminada, a tensão pode permanecer em níveis significativamente reduzidos durante vários segundos. Esse atraso de tempo é geralmente causado pela alta concentração de motores de indução. Portanto, torna-se necessária a realização de estudos para analisar os impactos que esse tipo de fonte de energia pode trazer para o sistema elétrico bem como o impacto das cargas sobre o gerador eólico. Assim, este trabalho faz uma análise da influência de cargas do tipo motor de indução sobre o comportamento dinâmico de um DFIG conectado a um sistema de distribuição. Um gerador síncrono convencional também foi utilizado para fazer uma comparação com o DFIG. Como os dois geradores estão atuando com regulação de tensão, seria intuitivo pensar que as respostas dos dois na presença de cargas do tipo motor de indução, fossem semelhantes. No entanto, este trabalho mostra que diante do mesmo cenário, as máquinas têm comportamentos diversos e a reação é diferente dependendo do tipo de carga conectada ao sistema. Foi verificado que, quando existe o problema FIDVR devido à presença de cargas do tipo motor de indução, as oscilações na velocidade do DFIG são amplificadas. Já para o gerador síncrono, a carga do tipo motor de indução possui pouca influência nas oscilações eletromecânicas. / With the advent of distributed generation, the operation of the distribution system has been modified. Dynamic characteristics that were previously observed only in the transmission system can now also be present in distribution systems, such as problems related to electromechanical oscillations. Due to growth prospects of wind generator connections, it is evident the possibility of increasing the production of electricity through asynchronous distributed generators. In the distribution system several types of loads are present, being one of the most representative the loads of type induction motor. This type of load, the occurrence of short-circuits in the system can cause delay in the recovery of the system voltage, known as Fault Induced Delayed Voltage Recovery (FIDVR) problem. After the fault is eliminated, the voltage can remain at significantly reduced levels for several seconds. This time delay is usually caused by the high concentration of induction motors. So, it is necessary to perform studies to analyze the impacts that this type of energy source can bring to the electrical system as well as the impact of the loads on the wind generator. Thus, this thesis makes an analysis of the influence of induction motor loads on the dynamic behavior of a DFIG connected to a distribution system. A conventional synchronous generator was also used to make a comparison with the DFIG. As the two generators are working with voltage regulation, it would be intuitive to think that the responses of the two in the presence of induction motor loads would be similar. However, this thesis shows that in the same scenario, the machines have different behaviors and the reaction is different according to the type of load connected to the system. It was verified that when there is the FIDVR problem due to the presence of the induction motor, the oscillations in the speed of the DFIG are amplified. For the synchronous generator, the induction motor has little influence on the electromechanical oscillations.
109

Avaliação do impacto da geração distribuída sobre o sistema de proteção de sobrecorrente de uma rede de distribuição operando em ilhamento intencional / Impact assessment of the distributed generation on the overcurrent protection system of a distribution network operating in intentional islanding

Robson Roberto Sguaçabia 26 March 2015 (has links)
O crescente número de geradores distribuídos conectados em redes de distribuição de energia elétrica é uma realidade dos sistemas elétricos de todo o mundo. Embora a política atual seja desconectar os geradores distribuídos do sistema elétrico de potência (SEP) caso ocorra uma falha na rede da concessionária, conforme preconizam os principais guias técnicos nacionais e internacionais, o módulo 3 dos Procedimentos de Distribuição de Energia Elétrica no Sistema Elétrico Nacional (PRODIST) mostra-se favorável à operação ilhada, pois afirma que este tipo de operação pode ser realizado em comum acordo entre as centrais geradoras de energia e o Operador Nacional do Sistema Elétrico (ONS), permitindo alcançar uma maior disponibilidade no fornecimento de energia. No entanto, para que a operação ilhada seja possível e possa ser praticada de forma segura, o ilhamento intencional precisa superar alguns desafios, dentre os quais estão aqueles relacionados ao sistema de proteção da rede de distribuição, tais como: coordenação indevida de dispositivos de proteção, perda da sensibilidade da proteção, abertura inadequada de fusíveis e religamentos automáticos fora de sincronismo. Portanto, este trabalho avalia o impacto da geração distribuída (GD) sobre o sistema de proteção de sobrecorrente de uma rede de distribuição operando ilhada. A ideia principal é dividir a rede em regiões delimitadas pelos dispositivos de proteção existentes, para em seguida, adequá-los à nova situação operacional, certificando se os ajustes propostos atendem ao comportamento síncrono e estável do sistema de geração por meio de uma análise de estabilidade transitória. Propõe-se então um conjunto de procedimentos para tomada de ações que permitam readequar o sistema de proteção de sobrecorrente existente à operação ilhada. Os resultados obtidos demonstram que a inibição do religamento automático e da curva de atuação instantânea acrescida de reajustes nas curvas temporizadas dos relés e religadores, melhoraram a coordenação e seletividade da rede operando ilhada. / The growing number of distributed generators connected to electricity distribution networks is a reality of electrical systems throughout the world. Although the current policy is to disconnect the distributed generators from the electric power system (EPS) in the event of loss of mains, as required by main national and international technical guides, the module 3 of the Procedures for Electric Power Distribution in the Electric National System (PRODIST) shows itself in favor of islanded operation, it states that this type of operation can be carried out in agreement between power generation plants and the National Electric System Operator (ONS), allowing achieve larger availability in energy supply. However, to make the islanded operation possible and safe, the intentional islanding must overcome some challenges, among which are those related to the protection system of the distribution network, such as improper coordination of protective devices, loss of protection sensitivity, inadequate opening of fuses and automatic reclosing out of synchronism. Therefore, this work evaluates the impact of distributed generation (DG) on the overcurrent protection system of a distribution network operating islanded. The main idea is to divide the network into regions bounded by existing protection devices, to then adapt them to the new operational situation, making sure that the proposed adjustments meet the synchronous and stable behavior of the generation system by means of a transient stability analysis. Thus, a set of procedures is proposed to indicate actions that allow readjusting the existing overcurrent protection system to the islanded operation. The results demonstrate that the inhibition of automatic restart and of the instantaneous operating curve plus adjustments in time delay curves of relays and reclosers, improved the coordination and selectivity of the network operating islanded.
110

Projeto e SimulaÃÃo de Filtros L e LCL para InterconexÃo de Inversor NPC TrifÃsico à Rede / Design and Simulation of L and LCL Filters for the Interconnection of a Three Phase NPC Inverter to the Grid

Romulo Diniz Araujo 05 March 2012 (has links)
Este trabalho apresenta o estudo de um inversor NPC de 6 kW e 380 V, trifÃsico, para interconexÃo de sistemas de geraÃÃo distribuÃda à rede elÃtrica. O inversor à estudado nas frequÃncias de chaveamento de 3, 4 e 6 kHz, sendo interligado à rede elÃtrica atravÃs dos filtros L e LCL. Para identificar qual filtro passivo, L ou LCL, se adequa melhor ao inversor em estudo foram realizadas simulaÃÃes numÃricas para diferentes situaÃÃes, validando o projeto do inversor e a modelagem vetorial desenvolvida. A resposta do controle à satisfatÃria, pois o inversor à capaz de controlar o fluxo de potÃncia ativa e reativa entregues à rede elÃtrica. Diante dos resultados obtidos percebeu-se que o filtro LCL apresentou um menor conteÃdo harmÃnico para as trÃs frequÃncias estudadas em relaÃÃo ao filtro L. Ambos os filtros atenderam aos requisitos da norma Std IEEE 1543, no entanto o filtro L à o mais indicado para o inversor em estudo, pois alÃm de atender a norma, o mesmo apresenta um menor custo quando comparado ao filtro LCL. / This paper presents the study of a 6 kW, 380 V, three phase NPC inverter for interconnecting distributed generation unit to the grid. The inverter is studied with switching frequency of 3, 4 and 6 kHz, and it is interconnected to the grid through L and LCL filters. To identify which passive filter, L or LCL, is best suited to the inverter under study, a mathematical model has been proposed and several numerical simulations have been carried out to validate the design of the inverter and vector model developed. The control response is satisfactory, since the inverter is able to control the flow of active and reactive power delivered to the grid. Based on these results it was noticed that the LCL filter showed a lower harmonic content for the three frequencies studied in relation to the filter L. Both filters met the requirements of the standard IEEE Std 1543, however the filter L is the most suitable for the inverter under study, because the filter L not only meet the standard but also it presents a lower cost when compared to the LCL filter.

Page generated in 0.1016 seconds