Spelling suggestions: "subject:"distributed 1generation"" "subject:"distributed 4egeneration""
271 |
A Proposed Rule For The Interconnection Of Distributed Generation And Its Economic JustificationGezer, Dogan 01 December 2009 (has links) (PDF)
Distributed generation (DG) is electricity generation by small generating units, which are interconnected at distribution level with capacity less than 50 MW. Environmental concerns and the idea of using cheap and domestic renewable resources increased the popularity of DG following the developments in equipment technology. In Turkey, interconnection of DG is realized through the distribution busbars of 154/36 kV substation. The interconnection of DG at 36 kV feeders is not allowed by distribution system authority. This thesis proposes an interconnection rule which includes technical analyses to be conducted before the permission of interconnection of DG at 36 kV feeders. Moreover, the protection functions and operational requirements needed for the proper and safe operation of distribution system in presence of DG are introduced. A sample distribution system with relevant parameters is used for the simulation studies in Digsilent software. In order to determine the operational reserve requirement against the variations in wind generation, a statistical method including Weibull distribution, standard deviation and monthly average wind speeds is used. Convenience of hydropower plants&rsquo / response for being backup generation against the fluctuations in wind generation is analyzed by a mid-term dynamic model of the power system. A secondary control mechanism for the integration of wind power is suggested. Finally, an economic comparison between the interconnection alternatives of hydropower and photovoltaic power plants at the distribution busbar of the 154/36 kV substation and the 36 kV feeder is done by present worth analysis using the up to date power plant costs and incentives.
|
272 |
An analysis of DC distribution systemsAjitkumar, Rohit 05 April 2011 (has links)
The Master's Thesis research focuses on analyzing the possibilities of using Direct Current distribution systems to distribute power to end users. Considering the shift in load types in the past few decades and also a growing demand of distributed generation, DC distribution can potentially offer higher efficiencies and cost savings to utilities. The incorporation of DC distribution offers the opportunity to eliminate multiple conversion stages for devices which are powered using DC electricity. The integration of power sources such as photovoltaics and fuel cells, which produce DC power, offer further incentives to consider the use of DC systems. Using DC systems can help eliminate the conversion losses associated with rectifiers and inverters which would be part of the infrastructure if AC distribution was used. In the literature, the study of DC distribution has been limited to customized systems. The objective of this research is to analyze DC distribution when applied to systems based on standard IEEE test feeder systems. The IEEE 13 node test feeder and the IEEE 37 node test feeder will be used as the basis for the analysis. Issues such as associated costs, protection and integration of appliances will also be addressed.
|
273 |
System Studies and Simulations of Distributed Photovoltaics in SwedenWidén, Joakim January 2010 (has links)
Grid-connected photovoltaic (PV) capacity is increasing worldwide, mainly due to extensive subsidy schemes for renewable electricity generation. A majority of newly installed systems are distributed small-scale systems located in distribution grids, often at residential customers. Recent developments suggest that such distributed PV generation (PV-DG) could gain more interest in Sweden in the near future. With prospects of decreasing system prices, an extensive integration does not seem impossible. In this PhD thesis the opportunities for utilisation of on-site PV generation and the consequences of a widespread introduction are studied. The specific aims are to improve modelling of residential electricity demand to provide a basis for simulations, to study load matching and grid interaction of on-site PV and to add to the understanding of power system impacts. Time-use data (TUD) provided a realistic basis for residential load modelling. Both a deterministic and a stochastic approach for generating different types of end-use profiles were developed. The models are capable of realistically reproducing important electric load properties such as diurnal and seasonal variations, short time-scale fluctuations and random load coincidence. The load matching capability of residential on-site PV was found to be low by default but possible to improve to some extent by different measures. Net metering reduces the economic effects of the mismatch and has a decisive impact on the production value and on the system sizes that are reasonable to install for a small-scale producer. Impacts of large-scale PV-DG on low-voltage (LV) grids and on the national power system were studied. Power flow studies showed that voltage rise in LV grids is not a limiting factor for integration of PV-DG. Variability and correlations with large-scale wind power were determined using a scenario for large-scale building-mounted PV. Profound impacts on the power system were found only for the most extreme scenarios. / Felaktigt tryckt som Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology 711
|
274 |
OPTIMAL DISTRIBUTED GENERATION SIZING AND PLACEMENT VIA SINGLE- AND MULTI-OBJECTIVE OPTIMIZATION APPROACHESDarfoun, Mohamed 09 July 2013 (has links)
Numerous advantages attained by integrating Distributed Generation (DG) in distribution systems. These advantages include decreasing power losses and improving voltage profiles. Such benefits can be achieved and enhanced if DGs are optimally sized and located in the systems. In this thesis, the optimal DG placement and sizing problem is investigated using two approaches. First, the optimization problem is treated as single-objective optimization problem, where the system’s active power losses are considered as the objective to be minimized. Secondly, the problem is tackled as a multi-objective one, focusing on DG installation costs. These problems are formulated as constrained nonlinear optimization problems using the Sequential Quadratic Programming method. A weighted sum method and a fuzzy decision-making method are presented to generate the Pareto optimal front and also to obtain the best compromise solution. Single and multiple DG installation cases are studied and compared to a case without DG, and a 15-bus radial distribution system and 33-bus meshed distribution system are used to demonstrate the effectiveness of the proposed methods.
|
275 |
Maximum power point tracking algorithm for photovoltaic home power supply.Nkashama, Cedrick Lupangu. January 2011 (has links)
Solar photovoltaic (PV) systems are distributed energy sources that are an environmentally friendly
and renewable source of energy. However, solar PV power fluctuates due to variations in radiation
and temperature levels. Furthermore, when the solar panel is directly connected to the load, the power
that is delivered is not optimal. A maximum peak power point tracker is therefore necessary for
maximum efficiency.
A complete PV system equipped maximum power point tracking (MPPT) system includes a solar
panel, MPPT algorithm, and a DC-DC converter topology. Each subsystem is modeled and simulated
in a Matlab/Simulink environment; then the whole PV system is combined with the battery load to
assess the overall performance when subjected to varying weather conditions.
A PV panel model of moderate complexity based on the Shockley diode equation is used to predict
the electrical characteristics of the cell with regard to changes in the atmospheric parameter of
irradiance and temperature.
In this dissertation, five MPPT algorithms are written in Matlab m-files and investigated via
simulations. The standard Perturb and Observe (PO) algorithm along with its two improved versions
and the conventional Incremental Conductance (IC) algorithm, also with its two-stage improved
version, are assessed under different atmospheric operating conditions. An efficient two-mode MPPT
algorithm combining the incremental conductance and the modified constant voltage methods is
selected from the five ones as the best model, because it provides the highest tracking efficiencies in
both sunny and cloudy weather conditions when compared to other MPPT algorithms.
A DC-DC converter topology and interface study between the panel and the battery load is performed.
This includes the steady state and dynamic analysis of buck and boost converters and allows the
researcher to choose the appropriate chopper for the current PV system. Frequency responses using
the state space averaged model are obtained for both converters. They are displayed with the help of
Bode and root locus methods based on their respective transfer functions. Following the simulated
results displayed in Matlab environment for both choppers, an appropriate converter is selected and
implemented in the present PV system. The chosen chopper is then modeled using the Simulink
Power Systems toolbox and validates the design specifications.
The simulated results of the complete PV system show that the performances of the PV panel using
the improved two-stage MPPT algorithm provides better steady state and fast transient characteristics
when compared with the conventional incremental conductance method. It yields not only a reduction
in convergence time to track the maximum power point MPP, but also a significant reduction in
power fluctuations around the MPP when subjected to slow and rapid solar irradiance changes. / Thesis (M.Sc.Eng)-University of KwaZulu-Natal, Durban, 2011.
|
276 |
Power quality and inverter-generator interactions in microgridsPaquette, Andrew Donald 22 May 2014 (has links)
This research addresses some of the difficulties faced when operating voltage controlled inverters with synchronous generators in microgrids. First, an overview of microgrid value propositions is provided, and the problems faced when attempting to use microgrids to provide improved power quality are discussed. Design considerations for different types of microgrids are provided to enable microgrids to deliver the desired functionality without adding unnecessary cost. The main body of this research investigates the poor transient load sharing encountered between voltage controlled inverters and synchronous generators in islanded operation. Poor transient load sharing results in high peak inverter rating requirements and high cost. The tradeoff between power quality and power sharing is highlighted, and methods to improve transient load sharing are proposed. The use of current limiting to protect inverters during faults and overloads is also investigated. Stability problems are identified when using simple inverter current limiting methods when operating in parallel with synchronous generators. Virtual impedance current limiting is proposed to improve transient stability during current limiting. The methods proposed in this thesis for mitigating inverter overloads and faults will allow for more reliable and cost effective application of inverter based distributed energy resources with synchronous generators in microgrids.
|
277 |
Totara Valley micro-hydro development : a thesis presented in partial fulfillment of the requirements for the degree of Master of Applied Science in Renewable Energy Engineering, Massey University, Palmerston North, New ZealandDonnelly, David Ronald Unknown Date (has links)
This study focuses on the design, construction and operation of a distributed generation system based on micro-hydro technology. The project is sited in the Totara Valley, a small rural community approximately 70km from the Massey University, Turitea campus, Palmerston North. The Massey University Centre for Energy Research (MUCER) has a long history of renewable energy research within the Totara Valley community. This project complements these existing schemes and provides a foundation for future research into distributed generation technologies. The project encompasses the following objectives: - to gain practical experience in the design, engineering and implementation of a distributed generation system in rural New Zealand; - to evaluate contemporary micro-hydro technology and compare the performance of this equipment in a theoretical and practical context; - to identify barriers that hinder the widespread adoption of micro-hydro systems in rural New Zealand; - to develop a spreadsheet based life cycle costing tool. The results from this study demonstrate that economic considerations are the fundamental aspect to be considered when assessing the long-term viability of these projects. The viability of micro-hydro projects are primarily determined by four factors: - the volume and head (height) of water available above the turbine site; - the length and therefore the cost of the pipeline required for transporting water to the turbine; - the legal and administrative costs involved in obtaining a resource consent to maintain access to the water resources; - the prices received and paid for electricity. Considerable charges were payable to the local authority to secure and maintain the right to harness the water resources at this site. This cost contributed considerable risk to the project and creates a significant barrier to establishing similar systems at other sites. The reduction of resource consent charges to levels that fairly reflect the negligible environmental impacts of these projects would encourage the adoption of this technology and deliver benefits to rural New Zealand communities.
|
278 |
Totara Valley micro-hydro development : a thesis presented in partial fulfillment of the requirements for the degree of Master of Applied Science in Renewable Energy Engineering, Massey University, Palmerston North, New ZealandDonnelly, David Ronald Unknown Date (has links)
This study focuses on the design, construction and operation of a distributed generation system based on micro-hydro technology. The project is sited in the Totara Valley, a small rural community approximately 70km from the Massey University, Turitea campus, Palmerston North. The Massey University Centre for Energy Research (MUCER) has a long history of renewable energy research within the Totara Valley community. This project complements these existing schemes and provides a foundation for future research into distributed generation technologies. The project encompasses the following objectives: - to gain practical experience in the design, engineering and implementation of a distributed generation system in rural New Zealand; - to evaluate contemporary micro-hydro technology and compare the performance of this equipment in a theoretical and practical context; - to identify barriers that hinder the widespread adoption of micro-hydro systems in rural New Zealand; - to develop a spreadsheet based life cycle costing tool. The results from this study demonstrate that economic considerations are the fundamental aspect to be considered when assessing the long-term viability of these projects. The viability of micro-hydro projects are primarily determined by four factors: - the volume and head (height) of water available above the turbine site; - the length and therefore the cost of the pipeline required for transporting water to the turbine; - the legal and administrative costs involved in obtaining a resource consent to maintain access to the water resources; - the prices received and paid for electricity. Considerable charges were payable to the local authority to secure and maintain the right to harness the water resources at this site. This cost contributed considerable risk to the project and creates a significant barrier to establishing similar systems at other sites. The reduction of resource consent charges to levels that fairly reflect the negligible environmental impacts of these projects would encourage the adoption of this technology and deliver benefits to rural New Zealand communities.
|
279 |
Totara Valley micro-hydro development : a thesis presented in partial fulfillment of the requirements for the degree of Master of Applied Science in Renewable Energy Engineering, Massey University, Palmerston North, New ZealandDonnelly, David Ronald Unknown Date (has links)
This study focuses on the design, construction and operation of a distributed generation system based on micro-hydro technology. The project is sited in the Totara Valley, a small rural community approximately 70km from the Massey University, Turitea campus, Palmerston North. The Massey University Centre for Energy Research (MUCER) has a long history of renewable energy research within the Totara Valley community. This project complements these existing schemes and provides a foundation for future research into distributed generation technologies. The project encompasses the following objectives: - to gain practical experience in the design, engineering and implementation of a distributed generation system in rural New Zealand; - to evaluate contemporary micro-hydro technology and compare the performance of this equipment in a theoretical and practical context; - to identify barriers that hinder the widespread adoption of micro-hydro systems in rural New Zealand; - to develop a spreadsheet based life cycle costing tool. The results from this study demonstrate that economic considerations are the fundamental aspect to be considered when assessing the long-term viability of these projects. The viability of micro-hydro projects are primarily determined by four factors: - the volume and head (height) of water available above the turbine site; - the length and therefore the cost of the pipeline required for transporting water to the turbine; - the legal and administrative costs involved in obtaining a resource consent to maintain access to the water resources; - the prices received and paid for electricity. Considerable charges were payable to the local authority to secure and maintain the right to harness the water resources at this site. This cost contributed considerable risk to the project and creates a significant barrier to establishing similar systems at other sites. The reduction of resource consent charges to levels that fairly reflect the negligible environmental impacts of these projects would encourage the adoption of this technology and deliver benefits to rural New Zealand communities.
|
280 |
Totara Valley micro-hydro development : a thesis presented in partial fulfillment of the requirements for the degree of Master of Applied Science in Renewable Energy Engineering, Massey University, Palmerston North, New ZealandDonnelly, David Ronald Unknown Date (has links)
This study focuses on the design, construction and operation of a distributed generation system based on micro-hydro technology. The project is sited in the Totara Valley, a small rural community approximately 70km from the Massey University, Turitea campus, Palmerston North. The Massey University Centre for Energy Research (MUCER) has a long history of renewable energy research within the Totara Valley community. This project complements these existing schemes and provides a foundation for future research into distributed generation technologies. The project encompasses the following objectives: - to gain practical experience in the design, engineering and implementation of a distributed generation system in rural New Zealand; - to evaluate contemporary micro-hydro technology and compare the performance of this equipment in a theoretical and practical context; - to identify barriers that hinder the widespread adoption of micro-hydro systems in rural New Zealand; - to develop a spreadsheet based life cycle costing tool. The results from this study demonstrate that economic considerations are the fundamental aspect to be considered when assessing the long-term viability of these projects. The viability of micro-hydro projects are primarily determined by four factors: - the volume and head (height) of water available above the turbine site; - the length and therefore the cost of the pipeline required for transporting water to the turbine; - the legal and administrative costs involved in obtaining a resource consent to maintain access to the water resources; - the prices received and paid for electricity. Considerable charges were payable to the local authority to secure and maintain the right to harness the water resources at this site. This cost contributed considerable risk to the project and creates a significant barrier to establishing similar systems at other sites. The reduction of resource consent charges to levels that fairly reflect the negligible environmental impacts of these projects would encourage the adoption of this technology and deliver benefits to rural New Zealand communities.
|
Page generated in 0.1307 seconds