361

Análise de alternativas de proteção anti-ilhamento de geradores síncronos distribuídos / Analyzes of alternatives of anti-slanding protection of distributed synchronous generators

Mota, Igor Lopes 18 September 2015 (has links)
Submitted by JÚLIO HEBER SILVA (julioheber@yahoo.com.br) on 2017-03-24T19:57:30Z No. of bitstreams: 2 Dissertação - Igor Lopes Mota - 2015.pdf: 2620143 bytes, checksum: c895dad8e571f14172d9b7e9506f3d94 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-03-28T11:35:07Z (GMT) No. of bitstreams: 2 Dissertação - Igor Lopes Mota - 2015.pdf: 2620143 bytes, checksum: c895dad8e571f14172d9b7e9506f3d94 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-03-28T11:35:07Z (GMT). No. of bitstreams: 2 Dissertação - Igor Lopes Mota - 2015.pdf: 2620143 bytes, checksum: c895dad8e571f14172d9b7e9506f3d94 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2015-09-18 / In this dissertation, we present a detailed study of techniques for islanding detection of distribution systems in the presence of distributed generators in various forms of access and connection. The aim is to set up protection system solutions capable of ensuring the detection of the islanding based on local passive techniques, which have lower costs with respect to remote techniques, for example, the transfer trip. The objective of this work is to achieve through the association of several islanding detection techniques in order to achieve adequate reliability of distributed synchronous generators protection system. Among the existing techniques, the protection functions studied were the overfrequency and underfrequency (ANSI 81 o/u), rate of change of frequency (ROCOF or ANSI 81 df/dt), vector jump (ANSI 78) and directional reactive power (ANSI 32Q). It was found that the 32Q function for loads with inductive power factor less than one complements the functions based on frequency precisely in the range where these are insensitive to islanding, wherein the threshold for operation of this relay depends on the equivalent load power consumed locally. For cases of islanding caused the intentional opening of the distribution feeder, the islanding detection for loads with a inductive power factor can be guaranteed with the use of passive local techniques without the need to burden the installation of synchronous generators protection systems distributed. Although in practice it is very unlikely a distribution circuit has a unity power factor, the association of these protective functions arises as a good solution for the detection of islanding of distributed synchronous generators. / Nesta dissertação de mestrado apresenta-se um estudo das principais técnicas de detecção de ilhamento de geradores distribuídos considerando dados reais de 3 acessantes com diferentes capacidades de geração e diferentes tensões de conexão com o sistema interligado. Visa definir soluções de composição de sistemas de proteção capazes de garantir a detecção do ilhamento baseados em técnicas locais passivas, que apresentam custos mais reduzidos com relação às técnicas remotas, como por exemplo, a teleproteção. O objetivo deste trabalho é alcançar, por meio de associação de várias técnicas de detecção de ilhamento, um grau de confiabilidade adequado do sistema de proteção de geradores síncronos distribuídos. Dentre as técnicas existentes, foram estudadas as funções de proteção de sub e sobrefrequência (ANSI 81 o/u), taxa de variação de frequência (ROCOF ou ANSI 81 df/dt), salto de vetor (ANSI 78) e direcional de potência reativa (ANSI 32Q). Constatouse que a função 32Q, para cargas com fator de potência indutivo e menor que um, complementa as funções baseadas em frequência justamente na faixa onde estas são insensíveis a ilhamentos, sendo que o limite para a operação deste relé depende da potência equivalente da carga consumida localmente. Para os casos de ilhamento provocado pela abertura intencional do alimentador de distribuição, a detecção de ilhamento para cargas com fator de potência indutivo poderá ser garantida com a utilização das técnicas locais passivas sem a necessidade de se onerar a instalação dos sistemas de proteção de geradores síncronos distribuídos. Apesar de que na prática é muito improvável um circuito de distribuição possuir um fator de potência unitário, a associação das referidas funções de proteção surge como uma boa solução para a detecção de ilhamentos de geradores síncronos distribuídos.
362

Desenvolvimento de metodologias de análise sistêmica de sistemas de distribuição de energia elétrica com geração ultra-dispersa / Development of methods for systemic analysis of electric power distribution systems with ultra-dispersed generation

Borges, Ricardo Torquato, 1989- 26 August 2018 (has links)
Orientador: Walmir de Freitas Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-26T08:13:15Z (GMT). No. of bitstreams: 1 Borges_RicardoTorquato_M.pdf: 3452590 bytes, checksum: db90e4d373020ef903f89b6b280df04a (MD5) Previous issue date: 2014 / Resumo: Os impactos causados pela instalação de geradores trifásicos de médio porte (? 1 MVA) diretamente em redes primárias de distribuição de energia elétrica (com tensão ? 10 kV) têm sido intensivamente investigados nos últimos 10 anos. Por conseguinte, atualmente, práticas de análise, operação e proteção são relativamente bem definidas e aceitas. No período de amadurecimento dessa mudança de paradigma em relação à geração de energia elétrica, de forma geral os engenheiros das concessionárias analisam uma solicitação de um novo acessante por vez, emitindo um relatório sobre as necessidades ou não de alteração do projeto. Contudo, com a publicação da Resolução Normativa #482 e outras ações, verifica-se o interesse do governo brasileiro em incentivar a conexão de geração distribuída baseada em fontes renováveis (sobretudo geradores fotovoltaicos) em redes secundárias de forma intensa e extensa. Isso produz um cenário diferente do previamente investigado na maioria dos projetos de pesquisa realizados nos últimos 10 anos, criando a necessidade de novos estudos e metodologias de análise. Neste contexto, esta dissertação de mestrado apresenta uma metodologia de análise probabilística que utiliza simulações Monte Carlo para identificar o impacto agregado de múltiplos geradores fotovoltaicos. São apresentadas técnicas para modelar todas as incertezas do problema, as quais estão relacionadas principalmente com a potência produzida pelos geradores e consumida pelas cargas em cada instante do dia. São desenvolvidas também duas aplicações práticas do método de análise proposto. A primeira aplicação consiste no desenvolvimento de índices técnicos capazes de estimar de forma simples e rápida (sem realizar nenhuma simulação) a potência máxima que pode ser injetada em redes secundárias sem a ocorrência de violações técnicas. A segunda aplicação consiste em uma técnica para estimar o impacto futuro da geração fotovoltaica em determinado alimentador da concessionária, de forma a auxiliar os engenheiros no planejamento da expansão das redes de distribuição. O método de análise e as aplicações apresentadas neste trabalho podem auxiliar na redução do número de barreiras existentes para a conexão de geradores distribuídos fotovoltaicos / Abstract: Impacts caused by the connection of three-phase, medium size generators (? 1 MVA) directly to primary distribution networks (with voltage ? 10 kV) have been intensively investigated over the last 10 years. As a consequence, analysis, operation and protection practices are relatively well defined and accepted. During the maturation of this paradigm change on the electric energy generation, in general, utility engineers used to evaluate new connection requests individually, providing a report with possible requirements for project modifications. However, with the publication of Normative Resolution #482 and other actions, one may notice the interest of Brazilian government on encouraging the connection of renewable-based distributed generation (mainly photovoltaic generation) to secondary distribution networks. Such fact leads to a new scenario, different from the one investigated over the last 10 years, creating the need for new studies and analysis methodologies. In such context, this M.Sc. dissertation presents a probabilistic analysis methodology that adopts Monte Carlo simulations to identify the aggregated impact of multiple photovoltaic generators. Modelling techniques are presented for all problem uncertainties, which are mainly related to the power produced by generators and consumed by loads at each instant of the day. Two practical applications of the proposed method are also developed. The first application consists in developing technical indices that provide a simple and quick estimate (without performing any simulation) of the maximum power that may be injected into secondary networks without the occurrence of technical violations. The second application consists in a technique to estimate the future impact of photovoltaic generation on a utility feeder, in order to support engineers on the expansion planning of distribution networks. The analysis methodology and applications presented in this work can help to overcome the barriers for the interconnection of photovoltaic distributed generators / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
363

Metodologia para reposição de serviço e gestão de carga em microrredes inteligentes / Methodology for service reestablishment in smart microgrid by load shedding

Jacondino, Anderson Lopes 31 August 2016 (has links)
This work presents the development of a methodology to service replacement and management loads in islanded smart grid by load shedding, supported by Distributed Generation, to avoid or reduce violations of continuity indicators, subject to penalties for infringement, established in Module 8 of PRODIST, ANEEL (2015a). To adjust the power demanded by the load to the power generated during the islanding of microrrede specifies to the best loads to be rejected by Multicriteria Methodology Analytic Hierarchy Process - AHP. In applying of methodology it was considered as criteria the continuity indicators that generate compensation to consumers for violation, and also it was considered the priority of continuity of supply to loads. Thus, for the formation of the island, is obtained as a preliminary result, a classification of loads in order of need for service. The best loads classified will be reconnected to microrrede until that GD units do not support new loads or that they violate any of the restrictions, being the remaining loads rejected. In continuously, they was made a reassessment in every pre-set period of time in order to identify new possible loads shedding to be made. This revaluation occurs in two distinct scenarios, both for typical day as for critical day. Any Violations of system constraints are checked by software of load flow calculation. Thus, obtained as final result a whole of loads to be served during replacement or continuity of the service. / Este trabalho apresenta o desenvolvimento de uma metodologia para reposição de serviço e gestão de cargas em microrrede inteligente ilhada, suportada por unidades de Geração Distribuída, a fim de evitar ou atenuar violações dos indicadores de continuidade, passíveis de penalidades por violação, estabelecidos no Módulo 8 dos Procedimentos de Rede da Agência Nacional de Energia Elétrica PRODIST, ANEEL (2015a). Para adequar a potência demandada pelas cargas à potência gerada, durante o ilhamento da microrrede, definem-se as melhores cargas a serem rejeitadas, por meio da Metodologia Multicritério Analytic Hierarchy Process AHP. Na aplicação da metodologia foram considerados como critérios os indicadores de continuidade passíveis de compensações aos consumidores por violação, e também, foi considerada a prioridade de continuidade do fornecimento às cargas. Assim, para a formação da ilha, obtém-se como resultado preliminar, uma classificação das cargas em ordem de necessidade de atendimento. As cargas melhores classificadas são reconectadas à microrrede até que as unidades de GD não suportem novas cargas ou que ocorra a violação de alguma das restrições, sendo as demais cargas rejeitadas. De forma contínua, são feitas reavaliações a cada período de tempo pré-definido de forma a identificar novas possíveis rejeições ou reconexões de carga a serem realizados durante o ilhamento. Esta reavaliação ocorre em dois cenários distintos, tanto para dia típico como para dia crítico. Eventuais violações das restrições do sistema são verificadas por meio de software para cálculo de fluxo de carga. Desta forma, obtém-se como resultado final um conjunto de cargas a serem atendidas durante a reposição ou continuidade do serviço.
364

Modelo para a análise econômica e financeira em projetos para geração distribuída de energia com fontes alternativas / Model for the economic and financial analysis of distributed energy generation projects with alternative sources

Wottrich, Breno 27 September 2010 (has links)
The implementation of distributed generation (DG) offers many benefits to the society, the electrical sector where they operate, and the consumers connected to the network especially due to their electricity self-production. For this case, proponents normally fight against costs estimation problems in projects of DG. In this way, low-cost and quality pre-feasibility studies are crucial when choosing the best financial and economical option. This Master thesis works on a specific methodology, with the software HOMER®, to the economic and financial (as well technical) prefeasibility study of projects with several small DG sources connected to middle voltages. A case study is also implemented with input data collected in the region of the Federal University of Santa Maria (UFSM). Therefore, it is developed a structure enclosing the general and interdisciplinary context of the projects. It helps the decision making process concerning the best-cost criterion option to advance to a more detailed viability study. As a result, this analysis of small DG systems proved to be very insightful, aligning its general objectives with the preciseness of pointing out promising technologies (wind turbines and microturbines fuelled by biogas) for further detailed studies. / O incremento de geração distribuída (GD) oferece uma série de benefícios para a sociedade, ao setor elétrico no qual estão inseridas e aos consumidores conectados a rede - em especial através da auto-produção de energia. Sobretudo para esta última situação, proponentes buscam solucionar problemas de estimação de custos em projetos de GD realizando estudos de pré-viabilidade de qualidade. Estes são de baixo custo e críticos para auxiliar a descartar projetos que não fazem sentido financeiro e econômico. Esta dissertação de mestrado aborda uma análise, através de metodologia específica, utilizando o software HOMER®, para o estudo de pré-viabilidade econômica e financeira (assim como técnica) de projetos envolvendo uma ampla gama de fontes distribuídas de pequeno porte conectadas à média tensão, com estudo de caso envolvendo a Universidade Federal de Santa Maria RS (UFSM). Assim, desenvolve-se uma estrutura contemplando o contexto geral e interdisciplinar de projetos, para auxiliar a tomada de decisões referentes à melhor opção em custos para prosseguir a um estudo mais detalhado de viabilidade. Como resultado, a proposta para análises de sistemas com GD de pequeno porte provou uma robustez interessante, aliando os objetivos gerais da abordagem desenvolvida com a precisão de apontar indícios tangíveis de viabilidade de tecnologias (turbinas eólicas e microturbinas a biogás) para estudos futuros mais detalhados.
365

Metodologia para análise da tarifa branca e da geração distribuída de pequeno porte nos consumidores residenciais de baixa tensão / Methodology for analysis of distributed generation and electricity tariff for residential consumers in lv network

Santos, Laura Lisiane Callai dos 28 February 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This Master s Dissertation presents the development of a methodology that analyzes the impact of the White Tariff considering the distributed generation to low voltage residential consumers. The White Tariff has the aim of encouraging the reduction of energy consumption during the time of highest system load by consumers. Besides the low-voltage distributed generation aims the energy efficiency, the use of distributed generation and energy management by consumer. Considering this, the proposed methodology considers electricity tariffs, typical load curves ranged by consumption levels, natural resources and different of technologies for distributed generation. This database, combined with the software Hybrid Optimization Model for Electric Renewables (HOMER), presents as the main result the technical and economic feasibility for the use of distributed generation together with the white tariff, without changing the spending habits of consumers. The use of distributed generation is prioritized during the peak time, shifting the consumption from the electric power network to off-peak periods, where the white electricity tariff is shiper. The current costs of installation and operation of the distributed generation are high, but there is a tendency to their reduction due to an increase of its application and providers. It is emphasized that these analyzes, never seen before aim more efficient energy use of energy by both the application of white tariff and the encouragement to use of distributed generation. / Esta dissertação apresenta o desenvolvimento de uma metodologia para analisar o impacto da Tarifa Branca considerando a inserção de geração distribuída (GD) nos consumidores residenciais de baixa tensão. A Tarifa Branca visa incentivar os consumidores de baixa tensão a reduzirem o consumo de energia elétrica no horário de maior carregamento do sistema. A geração distribuída permite o gerenciamento da energia por parte do consumidor. Neste sentido, a metodologia proposta considera tarifas de energia, curvas de carga típicas por faixa de consumo, recursos naturais e tipos de tecnologias para geração distribuída. Esta base de dados, aliada ao software Hybrid Optimization Model for Eletric Renewables (HOMER), tem como principal resultado a viabilidade técnica e econômica quanto à utilização da geração distribuída explorando a Tarifa Branca, sem que haja mudança nos hábitos de consumo dos consumidores. A utilização da geração distribuída é priorizada para o horário de ponta, de modo que a utilização da rede de energia elétrica se concentre nos horários fora-ponta, onde o preço da Tarifa Branca é menor. Os custos atuais de instalação e operação das GD são elevados, porém a tendência é a redução dos preços em função de um aumento no seu uso e na quantidade de fornecedores. Ressalta-se que tais análises são inéditas e visam o uso mais eficiente de energia tanto pelo emprego da Tarifa Branca como pelo incentivo para uso da geração distribuída.
366

Contribuições ao estudo de conexão de geração eólica à rede elétrica / Contributions to study of wind farm connection to the utility

Jaskulski, Igor Weide 24 August 2007 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / Distribution systems have not been designed to receive distributed generation (DG) units. The electric energy injection in these systems is safe and reliable if the characteristics regarding of DG interconnection in distribution power systems are considered: (i) Protection; (ii) Stability; (iii) Electric energy market; (iv) Quality of energy. In this work, aspects regarding of quality of energy and protection are studied. In the quality of energy aspect, converters with legs in parallel are approached. To demonstrate the power capability increase with converters with legs in parallel, the capabilities power curves of the converter are derived. Furthermore, a procedure to design an inductive filter from the distortion factor and limits of current harmonics is described. It is shown that converters with legs in parallel can be used to decrease the current harmonic content in the output of the DG and to increase the power curve capability of the converter. In the protection aspect, the stability analysis of an islanding detection method (IDM) based in positive feedback that has not Non-Detection-Zone (NDZ) is shown. A complete and a reduced dynamic model are derived. The results demonstrated that the reduced dynamic model is valid for the proposed analysis. Furthermore, a stable operation of an islanded utility section is demonstrated. However, if the IDM is added in the DG control system, it is possible a stable operation when the main utility is connected and an unstable operation when the DG unity is operating in islanding condition. Besides, the addition of a limiter in the output of the MDI can represent a limit cycle that induces a voltage oscillation in the islanded section that can be useful to under/over voltage relays coordination. Finally, a three phase converter with two legs per phase in parallel is used to validate the analyses. / Sistemas de distribuição não foram projetados para receber unidades de Geração Distribuída (GD). Para que a inserção de energia elétrica nesses sistemas ocorra de forma segura e com qualidade, as seguintes características relacionadas à conexão de GD a redes de distribuição devem ser consideradas: (i) Proteção; (ii) Estabilidade; (iii) Mercado de Energia; e (iv) Qualidade de Energia. Neste trabalho são estudados aspectos referentes à qualidade de energia e à proteção. No aspecto qualidade de energia, conversores com pernas em paralelo são abordados. Para demonstrar o aumento da capacidade de processamento de potência com conversores com pernas em paralelo, curvas de capabilidade de conversores são derivadas. Além disso, o procedimento de projeto de filtro indutivo a partir do fator de distorção e limites máximos de harmônicos de corrente é elaborado. Demonstra-se que essa abordagem de conversores permite a minimização do conteúdo harmônicos das correntes de saída da GD e a maximização das curvas de capabilidade do conversor. No aspecto proteção, é abordada a análise de estabilidade de método de detecção de ilhamento (MDI) local ativo, baseado na técnica com malha de realimentação positiva que não possui Zona de Não Detecção (ZND). Um modelo dinâmico completo e outro reduzido são derivados. Durante a análise, é demonstrado que o modelo dinâmico reduzido é válido para a análise do MDI. Além disso, é mostrado que uma operação estável é possível mesmo que a rede principal esteja desconectada. No entanto, ao adicionar o MDI, é possível ter uma operação estável quando a rede principal está presente e uma operação instável quando a unidade de GD está operando em condição ilhada. Ainda, a inserção da não-linearidade do limitador no MDI pode representar um ciclo limite, que induz uma oscilação na tensão no sistema ilhado que pode ser útil para a coordenação dos relés de sub/sobre tensão que detectam a ultrapassagem dos limites de tensões induzidas pelo MDI. Finalmente, um conversor trifásico com duas pernas por fase em paralelo é utilizado para validar as análises realizadas.
367

Low carbon technologies in low voltage distribution networks : probabilistic assessment of impacts and solutions

Navarro Espinosa, Alejandro January 2015 (has links)
The main outcome of this research is the development of a Probabilistic Impact Assessment methodology to comprehensively understand the effects of low carbon technologies (LCTs) in low voltage (LV) distribution networks and the potential solutions available to increase their adoption. The adoption of LCTs by domestic customers is an alternative to decreasing carbon emissions. Given that these customers are connected to LV distribution networks, these assets are likely to face the first impacts of LCTs. Thus, to quantify these problems a Monte Carlo-based Probabilistic Impact Assessment methodology is proposed in this Thesis. This methodology embeds the uncertainties related to four LCTs (PV, EHPs, µCHP and EVs). Penetration levels as a percentage of houses with a particular LCT, ranging from 0 to 100% in steps of 10%, are investigated. Five minute time-series profiles and three-phase four-wire LV networks are adopted. Performance metrics related to voltage and congestion are computed for each of the 100 simulations per penetration level. Given the probabilistic nature of the approach, results can be used by decision makers to determine the occurrence of problems according to an acceptable probability of technical issues. To implement the proposed methodology, electrical models of real LV networks and high resolution profiles for loads and LCTs are also developed. Due to the historic passive nature of LV circuits, many Distribution Network Operators (DNOs) have no model for them. In most cases, the information is limited to Geographic Information Systems (GIS) typically produced for asset management purposes and sometimes with connectivity issues. Hence, this Thesis develops a methodology to transform GIS data into suitable computer-based models. In addition, thousands of residential load, PV, µCHP, EHP and EV profiles are created. These daily profiles have a resolution of five minutes. To understand the average behaviour of LCTs and their relationship with load profiles, the average peak demand is calculated for different numbers of loads with and without each LCT.The Probabilistic Impact Assessment methodology is applied over 25 UK LV networks (i.e., 128 feeders) for the four LCTs under analysis. Findings show that about half of the studied feeders are capable of having 100% of the houses with a given LCT. A regression analysis is carried out per LCT, to identify the relationships between the first occurrence of problems and key feeder parameters (length, number of customers, etc.). These results can be translated into lookup tables that can help DNOs produce preliminary and quick estimates of the LCT impacts on a particular feeder without performing detailed studies. To increase the adoption of LCTs in the feeders with problems, four solutions are investigated: feeder reinforcement, three-phase connection of LCTs, loop connection of LV feeders and implementation of OLTCs (on-load tap changers) in LV networks. All these solutions are embedded in the Probabilistic Impact Assessment. The technical and economic benefits of each of the solutions are quantified for the 25 networks implemented.
368

Análise de técnicas de detecção de ilhamento ativas em sistemas de geração distribuída baseados em inversores fonte de tensão / Analysis of active islanding detection techniques in distributed generation systems based on voltage source inverters

Marina Silva Camillo de Carvalho 23 March 2017 (has links)
A abordagem principal desse trabalho é o estudo de técnicas anti-ilhamento ativas com realimentação positiva em um sistema de Geração Distribuída (GD) composto por um Inversor Fonte de Tensão (VSI,do inglês Voltage Source Inverter) e com cargas locais conectadas em paralelo. Na literatura são encontrados dois grupos de técnicas empregadas como proteção anti-ilhamento: as ativas e as passivas. Os métodos de detecção de ilhamento ativos são utilizados, pois possuem menores zonas de não detecção em comparação às técnicas passivas, porém injetam distúrbios contínuos no sistema de GD. Esses distúrbios degradam a qualidade de energia elétrica fornecida pelo conversor eletrônico. Nesse contexto, como escopo dessa dissertação, é realizado o estudo da estrutura de controle empregada no sistema de GD conectado com a rede de distribuição, com o intuito de avaliar o funcionamento do gerenciamento de tensão e de potência ativa e reativa. E em seguida, são discutidas técnicas de detecção de ilhamento ativas em frequência e tensão, ambas, com realimentação positiva e ganho fixo com o objetivo de investigar o desempenho das mesmas em relação ao tempo de detecção e a injeção de distúrbios no sistema de controle da GD. A partir dessa análise, são desenvolvidas técnicas anti-ilhamento com intuito de reduzir a injeção de distúrbios em diferentes pontos de operação da GD e garantir uma eficiência semelhante aos métodos tradicionais em casos de difícil detecção. Essas técnicas são baseadas na implementação do cálculo de um ganho com realimentação positiva variável inversamente proporcional a variação de potência ativa ou reativa entregue a rede. Para validação das propostas presentes nesta dissertação, são obtidos resultados em simulações computacionais e, posteriormente são adquiridos resultados práticos através de uma bancada experimental compatível com o sistema de GD simulado. / The main approach of this thesis is the study of active anti-islanding techniques with positive feedback in a Distributed Generation (DG) system composed by a Voltage Source Inverter (VSI) and local loads. In literature two groups of techniques are used as anti-island protection: the active and the passive techniques. The active islanding detection methods are preferably used because of the smaller non-detection zones compared to passive techniques, however they inject continuous disturbances in the DG system, reducing the power quality provided by the VSI. In this context, as the scope of this dissertation, it is firstly carried out the study of control structures employed in grid-tied distribution system, to evaluate the operation of the voltage control loops, and the active-and reactive power managements. Additionally, we discuss active islanding detection techniques in frequency and voltage with positive feedback and constant gain, based on the classical, with the objective of investigating their performance in relation to the detection time and the injection of disturbances in the DG system. From this analysis, antiislanding techniques are developed to guarantee efficiency similar to the traditional methods in cases of small-power flow through the grid and minimize disturbances. These techniques are based on the calculation of the positive feedback variable gain inversely proportional to the deviation of active or reactive power delivered or absorbed from the grid. To validate this proposal, the results are obtained through computational simulations and experimental analysis, as well.
369

Možnosti provozu sítě se zdroji rozptýlené výroby v ostrovním provozu / Options of network operation with distributed generation sources in island operation

Mareček, Tomáš January 2018 (has links)
This diploma thesis presents managing of the island mode using distributed generation. In the theoretical part of the thesis, the power system of the Czech Republic is described, together with its future development, and future development of installed capacity of distributed generation. Types of distributed generation are also mentioned. Next part of this work is focused on technological parts of islanding operation and its requirements. The following part describes components of the smart grids and mentions some of its functionalities. The practical part of the thesis describes the created models of components in PSCAD programme. From those components two slightly different grid models are created. On those grid models, simulations are made, during which island mode is created. Some of the grid functionalities are tested during those simulations, for example; reaction of the island mode for load increase, load decrease and others.
370

[pt] AVALIAÇÃO DINÂMICA DE ILHAMENTO DE SUBSISTEMAS ELÉTRICOS COM GERAÇÃO DISPERSA INTERLIGADOS À REDE DE TRANSMISSÃO / [en] DYNAMIC ASSESSMENT OF POWER SUBSYSTEMS ISLANDING WITH DISPERSED GENERATION INTERCONNECTED TO THE TRANSMISSION NETWORK

17 July 2017 (has links)
[pt] A topologia do sistema elétrico de potência vem se modificando devido à inserção da chamada Geração Distribuída ou Geração Dispersa, permitindo o atendimento da demanda crescente e, muitas vezes, mais próxima aos centros de consumo. Este tipo de geração tem sido explorado especialmente a partir de fontes renováveis não convencionais, como a eólica e a solar. Esta nova configuração do sistema traz questões de operação, controle e proteção. As ferramentas computacionais atualmente aplicadas nas análises dinâmicas terão que ser revistas de forma a incluir modelos que contemplem o comportamento estático e dinâmico dos novos elementos e seu impacto na rede interligada. Esta dissertação estuda, através de simulação dinâmica, o impacto da geração eólica, no comportamento dos esquemas de detecção de ilhamento diante de contingências que geram condições adversas na sub-rede ilhada com a geração dispersa. Para tanto, os geradores são modelados, considerando seus respectivos controles, de forma a aumentar a acurácia nas simulações dinâmicas dos sistemas com geração dispersa em situações de ilhamento, tendo em conta a seletividade e coordenação dos dispositivos de proteção. Finalmente, o trabalho propõe novas técnicas de implantação dos esquemas de detecção para este novo cenário nos sistemas elétricos. / [en] The typical electric power system topology has been changing as the so-called Distributed or Dispersed Generation, often located closer to the load centers, has been inserted into the power grid in order to meet the power demand growth. Some renewable sources, such as wind power and photovoltaic panels, are the most representative types of Dispersed Generation in this scenario. However, this new system configuration brings up operation, control and protection issues. The computer tools currently applied in dynamic studies will have to be revised in order to include models that represent correctly the steady state and the dynamic behavior of these new elements and their impact on the interconnected power system. This dissertation assesses, through dynamic simulation, the impact of dispersed generation, including wind power, on the islanding detection scheme behavior for events that generate adverse conditions on an islanded sub-grid with dispersed generation. The generators are modeled with their controllers in order to improve the dynamic simulation accuracy of the system in islanding situations taking into account the protection devices selectivity and coordination. Additionally, the work proposes a set of new techniques for the implementation of detection schemes applied in this new power system scenario.