• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Modèles intégrés pour l'évaluation des actions territoriales de réduction des émissions de gaz à effet de serre. Application aux réseaux de chaleur : Application aux réseaux de chaleur : HeatGrid, un modèle de simulation énergétique pour un management stratégique / Integrated models for evaluation of local actions for the reduction of greenhouse gases emissions : HeatGrid, an energy simulation model for a strategic management of district heating networks

Marguerite, Charlotte 24 March 2014 (has links)
Du fait de la flexibilité énergétique qu'ils offrent et de leur potentiel de diminution des émissions de GES et de polluants, les réseaux de chaleur (RdC) sont un des leviers d'actions des politiques énergétiques locales en constante progression. Leur déploiement et/ou rénovation n'est pas qu'une question technico-économique classique, dans la mesure où ils sont au cœur d'un ensemble d'acteurs interconnectés, aux objectifs spécifiques, tous parties prenantes des politiques énergétiques locales. Dans ce contexte, les outils permettant à ces différents acteurs l'évaluation des actions liées aux RdC sont très importants. Ils doivent permettre l'évaluation de scénarios de conception, d'actions de rénovation, de performance et de suivi... Parmi les outils permettant ces évaluations, les approches par modélisation sont souvent trop spécifiques à une situation, un type de réseau un acteur... Le travail réalisé consiste à développer un outils de modélisation de RdC, offrant la flexibilité recherchée. "HeatGrid" permet de modéliser des architectures de réseaux variées. A chaque pas de temps, le fonctionnement du réseau est simulé grâce au formalisme de la programmation linéaire. Cet outil peut être utilisé en phase de conception ou d'exploitation d'un réseau. L'approche de modélisation permet d'évaluer et de comparer sous les aspects économiques, énergétiques et techniques d'un RdC sous différents scénarios. Plusieurs exemples sont simulés et analysés dans le but d'illustrer le potentiel du modèle. / Because of the energy flexibility that they offer and their potential to reduce GHG emissions, disctrict heating (DH) networks are a tool of local energy policies in constant progression. Their develpment and/or renovation is not only a classic technico-economical question, insofar as interconnected stakeholders of local energy policies, taking into account specific objectives, are concerned by DH networks. In this context, tools which enable these different stakeholders to evaluate actions related to DH networks are essential. They must be helpful for the assessment of renovation actions, the monitoring and the evaluation of performances....Among the tools that allow theses evaluations, the modelling approaches are often too specific to a situation, a type of network, a stakeholder... The work of the thesis consists in developing a DH modeling tool that has this desired flexibility. The proposed tool "HeatGrid" can model various network architectures. At each time step, the network running is simulated via linear programming formalism. This tool can be applied either at the design stage of a DH or at the operating stage. The model based approach enables the evaluation and comparison of economic, energy and technical aspects of the DH system in different scenarios. Several examples are simulated and analyzed in order to illustrate the potential of the model.
2

Development of evaluation tools as an approach to pre-design district energy systems : Qualitative modeling and performance simulation using OpenModelica

Faramarzi, Ghazal, Torestam, Malin January 2020 (has links)
Cities and districts contribute to a large fraction of the total energy consumption in Sweden. The residential- and service sector accounted for almost 40% of the total energy consumption in 2018. The increasing urbanization also puts more importance on the energy supply, distribution and consumption in these areas. One way of planning an energy system in urban areas is to have integrated energy systems where synergies between different technologies and energy carriers are utilized. Such a solution can increase the flexibility of the energy system and thus help integrate more intermittent renewable energy sources. The aim of this study was to suggest tools for planning energy systems in districts. This was done by performing a literature review regarding the design of energy systems and the identification of barriers and opportunities for the integration of different production- and distribution technologies. The focus was on systems for heating, cooling and electricity. The proposed tools are three Excel-based modules. The first module is a qualitative model that presents the reviewed technologies and their connections. It also includes synergies between different energy carriers and sectors for consumption and production. The second module is qualitative model related to market mechanisms, juridical, organizational and institutional aspects. The third module is a table containing the barriers and opportunities. Furthermore, relevant stakeholders are identified to be district heating companies, building owners, joint associations, municipalities, district cooling companies and photovoltaic plant owners. The proposed tools can be used in the first stage of planning when the technologies are selected. To show how the suggested tools can be applied, a case study was performed. The study case is a district being planned in Stockholm, Sweden. For the analysis, a model for a hypothetical heating system was required. Two models were developed for the heat supply system using the modelling environment OpenModelica. The main objective of the case study was to compare the techno-economic and environmental performance of different scenarios. Three different scenarios were considered for covering the total heating demand in the district. In the first scenario the total heating demand is covered only by local heat pumps. In the second scenario the space heating demand is covered by heat pump(s) coupled with a thermal energy storage (hot water tank). An electric boiler is used as backup. In the third scenario, the electric boiler is replaced by district heating as backup. A sensitivity analysis was included for different numbers of heat pumps and different sizes of thermal energy storage in the two last scenarios. The economic and environmental results in this study were strongly dependent on the assumptions regarding prices and emission factors. The result of the case study indicates that the third scenario causes the lowest CO2 emissions. An increased size of the thermal energy storage causes a higher compressor electricity consumption thus more emissions. However the total emissions from the system depends on the backup component. For this result, the emission factor related to Swedish electricity mix and the emission factor stated by a district heating company in Stockholm was used. The cheapest alternative in terms of annual operational cost of energy is the first scenario with only heat pumps. However, from the scenarios which also includes thermal energy storage, the second scenario with three heat pumps and a 100 m3 large thermal energy storage, presents the lowest cost. This system design in scenario 2 is only 0.6% more expensive than the first scenario. For the energy prices, the assumption for electricity is based on hourly values from Nordpol and for heat, the values presented in a normal price list from a district heating company is assumed. Regarding the technical performance of the system the result indicates that the contribution from the thermal energy storage as it is modelled in this case study is not significant on anannual basis. However it is observed that a larger thermal energy storage unit covers a higher fraction of the power demand during the hours it is utilized. / Städer och stadsdelar står för en stor del av totala energikonsumtionen i Sverige. Bostads- och servicesektor stod för ungefär 40% av totala energikonsumtionen under 2018. Den ökande urbaniseringen lägger också mer vikt vid energiproduktion, distribution och konsumtionen i dessa områden. Ett alternativ för planering av energisystem i urbana områden är att ha integrerade energisystem där synergier mellan olika teknologier och energibärare kan utnyttjas. Den typen av system skulle kunna öka flexibiliteten i energisystemet och därför förenkla integrering av oförutsägbara förnybara energikällor. Syftet med denna studie var att föreslå verktyg för planering av energisystem i stadsdelar. Detta gjordes genom en litteraturstudie angående utformningen av olika energisystem samt identifiera hinder och möjligheter för att integrera olika produktions- och distributions teknologier. Fokus låg på systemen för värme, kyla och elektricitet. Det föreslagna verktygen är tre Excel baserade moduler. Den första modulen är en qualitative modell som presenterar de studerade teknologier och deras kopplingar. Den innehåller också synergier mellan de olika energibärarna och konsumtions- och produktionssektorn. Den andra modulen är en qualitative modell, men relaterad till marknad mekanismer, juridiska, organisatoriska och institutionella aspekter. Den tredje modulen är en tabell som beskriver hinder och möjligheter för några av teknologierna. Utöver det de relevanta aktörerna identifierades. För värme-, kyla- och elektricitet marknaden är de fjärrvärmeföretagen, fastighetsägare, samfälligheter, kommuner, fjärrkyla företagen, solcells ägare. De föreslagna verktyget kan användas för planering av energisystem i ett första skede när teknologier ska väljas.  En fallstudie genomfördes för att visa hur det föreslagna verktyget kan användas. Fallstudien en stadsdel som planeras i Stockholm, Sverige. För att genomföra en analys behövdes en modell för ett hypotetiskt värmesystem. Två modeller utvecklades för värmesystemet genom att använda modelleringsmiljön OpenModelica. Det huvudsakliga målet med fallstudien var att jämföra den teknoekonomiska- och miljöinriktade prestandan för olika scenarierna. Tre olika scenarier övervägdes för att täcka totala värmebehovet i stadsdelen. I det första scenariot täcks det totala värmebehovet endast av lokala värmepumpar. I andra scenariot täcks värmebehovet för uppvärmning av värmepump(ar) kopplade till en värmelagrings komponent (ackumulatortank). En elpanna användes för reserveffekt. I tredje scenariot är elpannan ersatt av fjärrvärme. En känslighetsanalys var utförd för olika antal värmepumpar kopplade till olika storlekar av värmelagrings-komponenten i de två sista scenarierna. De ekonomiska och miljörelaterade resultatet i den här studien är starkt beroende av antaganden gällande priser och utsläppsfaktorer. Resultatet indikerar att det tredje scenariot har de lägsta CO2 utsläppen. Ökad värmelagringsstorlek bidrar till att värmepumpen förbrukar mer elektricitet och därför ökar de relaterade utsläppen. Däremot beror de totala utsläppen i systemet på vilken reservkraft som används. För dessa resultat användes utsläppsfaktorn för svensk elmix samt utsläppsfaktorn från ett fjärrvärme företag i Stockholm. Den billigaste alternativet gällande årlig driftsenergikostnad är det första scenariot med endast värmepumpar. Däremot, bland de scenarion som innehåller värmelagring, har det andra scenariot med tre värmepumpar och 100m3 stor värmelagringsenhet den lägsta kostnaden. Detta system är endast 0.6% dyrare än det första scenariot. För energipriser har timvärden från Nordpol antagits för elektricitet och för värme har normalprislistan från ett fjärrvärmebolag i Stockholm antagits. Angående den tekniska systemprestandan, indikerar resultatet att bidraget från värmelagringsenheten som den är modellerad i den här fallstudien inte är signifikant på årsbasis. Det observeras emellertid att en större värmelagringsenhet täcker en större andel av effektbehovet under de timmar som enheten används.

Page generated in 0.0853 seconds