• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação ecocardiográfica modo-B, modo-M e Dopplerfluxométrica em Chelonoidis carbonaria (SPIX,1824) / Echocardiographic evaluation B-mode, M-mode and Dopplerfluxometric in Chelonoidis carbonaria (SPIX, 1824)

Bonatelli, Shayra Peruch [UNESP] 16 February 2017 (has links)
Submitted by SHAYRA PERUCH BONATELLI null (shayrabonatelli@gmail.com) on 2017-02-24T23:49:47Z No. of bitstreams: 1 Dissertação Repositório.pdf: 1006643 bytes, checksum: 238b25a3d3559dba4417f37e5c5bda4d (MD5) / Approved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-03-06T18:04:26Z (GMT) No. of bitstreams: 1 bonatelli_sp_me_bot.pdf: 1006643 bytes, checksum: 238b25a3d3559dba4417f37e5c5bda4d (MD5) / Made available in DSpace on 2017-03-06T18:04:26Z (GMT). No. of bitstreams: 1 bonatelli_sp_me_bot.pdf: 1006643 bytes, checksum: 238b25a3d3559dba4417f37e5c5bda4d (MD5) Previous issue date: 2017-02-16 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Os animais da espécie Chelonoidis carbonaria (Spix,1824) tem grande importância na questão conservacionista e vêm se tornando cada vez mais comuns como animais de estimação. O diagnóstico das diversas doenças em quelônios é um desafio para o clínico, pois a presença de casco e plastrão impede um exame físico detalhado com ausculta e palpação. A ecocardiografia tem se tornado valiosa no diagnóstico de diferentes afecções cardíacas. Este estudo teve como objetivo realizar a avaliação ecodopplercardiográfica em indivíduos Chelonoidis carbonaria (Spix,1824) a fim de estabelecer referências de normalidade que poderão auxiliar futuros diagnósticos de cardiopatias nestes animais. Ao modo-B observou-se um coração composto por três câmaras e duas válvulas atrioventriculares e em todos os animais observou-se fluído pericárdico. A Dopplerfluxometria revelou um padrão de onda de baixo fluxo na via de saída no ventrículo com velocidade média de pico sistólico de 34,10cm/s. O fluxo de preenchimento ventricular se mostrou bifásico, sendo que a razão entre o pico diastólico inicial e final mostrou-se menor que 1, tendo média de 0,66. A fração de encurtamento foi calculada por dois métodos, um atrial e outro ventricular, apresentando médias de 34,47% para o átrio direito, 46,90% para o esquerdo e 29,46% para o ventrículo, mantendo-se próximo à faixa de normalidade da fração de encurtamento ventricular conhecida para cães. Esta técnica ultrassonográfica se mostra de alta eficácia para avaliação cardíaca em animais da espécie Chelonoidis carbonaria, submetidos à anestesia geral. / The animals of the Chelonoidis carbonaria (Spix, 1824) specie have great importance in the conservacionist issue and are becoming increasingly common as pet. Diagnosis of various diseases in chelonian is a challenge for the clinician. The presence of shell and plastron avoid a detailed physical examination with auscultation and palpation. Echocardiography is very useful for diagnosis of different cardiac diseases. This study aimed to perform an echodopplercardiographic evaluation in Chelonoidis carbonaria (Spix, 1824) individuals to establish reference value, providing information for the future diagnosis of heart disease in these animals. At B-mode evaluation, we observed a heart consisted of three cameras and two atrioventricular valves and all the animals presented pericardial fluid. The Doppler ultrasound revealed a low flow wave pattern in the ventricular outflow with mean velocity of systolic peak of 34,10cm/s. The atrioventricular filling flow revealed a biphasic wave pattern, being the ratio between the diastolic and sistolic peak lower than one with mean value of 0,66. Shortening fraction was calculated by two methods, one atrial and another ventricular, with mean value of 34,47% for the right atrium, 46,90% for the left and 29,46% for the ventricle, remaining near the range of the ventricular shortening fraction already known for dogs. This sonographic technique shows high efficiency for the cardiac evaluation in animals of the Chelonoidis carbonaria (Spix, 1824) specie submitted to general anesthesia. / CNPq: 134265/2015-7
2

Avaliação ecocardiográfica modo-B, modo-M e Dopplerfluxométrica em Chelonoidis carbonaria (SPIX,1824)

Bonatelli, Shayra Peruch. January 2017 (has links)
Orientador: Maria Jaqueline Mamprim / Resumo: Os animais da espécie Chelonoidis carbonaria (Spix,1824) tem grande importância na questão conservacionista e vêm se tornando cada vez mais comuns como animais de estimação. O diagnóstico das diversas doenças em quelônios é um desafio para o clínico, pois a presença de casco e plastrão impede um exame físico detalhado com ausculta e palpação. A ecocardiografia tem se tornado valiosa no diagnóstico de diferentes afecções cardíacas. Este estudo teve como objetivo realizar a avaliação ecodopplercardiográfica em indivíduos Chelonoidis carbonaria (Spix,1824) a fim de estabelecer referências de normalidade que poderão auxiliar futuros diagnósticos de cardiopatias nestes animais. Ao modo-B observou-se um coração composto por três câmaras e duas válvulas atrioventriculares e em todos os animais observou-se fluído pericárdico. A Dopplerfluxometria revelou um padrão de onda de baixo fluxo na via de saída no ventrículo com velocidade média de pico sistólico de 34,10cm/s. O fluxo de preenchimento ventricular se mostrou bifásico, sendo que a razão entre o pico diastólico inicial e final mostrou-se menor que 1, tendo média de 0,66. A fração de encurtamento foi calculada por dois métodos, um atrial e outro ventricular, apresentando médias de 34,47% para o átrio direito, 46,90% para o esquerdo e 29,46% para o ventrículo, mantendo-se próximo à faixa de normalidade da fração de encurtamento ventricular conhecida para cães. Esta técnica ultrassonográfica se mostra de alta eficácia para avaliaçã... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre

Page generated in 0.0478 seconds