• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Durabilité de faisceaux électriques - approche multi-échelle des phénomènes de corrosion associés aux connexions entre câbles en alliage d'aluminium 1370 et éléments de connectique en cuivre / Durability of wiring harnesses - multiscale approach of local corrosion phenomena occurring in an aluminium alloy wire/copper connector assembly

Gravina, Rosanne 12 October 2016 (has links)
Cette thèse s'inscrit dans un programme de développement technologique de la Société LEONI. Ce programme de recherche a pour principal objectif de disposer, à l'issue des trois années de l'étude, d'un panel de connaissances scientifiques le plus pertinent possible relatif à la durabilité des faisceaux électriques, et plus particulièrement aux cinétiques de corrosion associées aux assemblages entre des câbles électriques en alliage d'aluminium AA1370 et des pièces de connectique en cuivre pur. La société LEONI souhaite également maîtriser les différentes étapes de fabrication de ces composants. En effet, les propriétés du câble, qui est constitué de fils en alliage d’aluminium AA1370, sont conditionnées par chacune des étapes du procédé de mise en forme de ces fils. Ainsi les travaux réalisés dans le cadre de cette thèse ont eu pour premier objectif d’analyser et de quantifier l’influence des différentes étapes de ce procédé de mise en forme sur le comportement en corrosion de l’alliage AA1370 sur la base d’une caractérisation précise de la microstructure du matériau aux différentes étapes du procédé. Les résultats mettent en évidence un couplage « résistance à la corrosion / paramètres microstructuraux critiques » à prendre en considération dans chacune des étapes de fabrication d’un câble en alliage AA1370. Ensuite, le comportement en corrosion d’un câble électrique a été étudié : les processus de corrosion mis en jeu au sein d’un câble constitué d’un nombre important de fils ont ainsi été identifiés, avec en particulier la problématique du confinement de l’électrolyte entre les différents fils du câble. Ces résultats montrent que la connaissance des processus électrochimiques se produisant sur un fil en alliage AA1370 ne suffit pas pour comprendre le comportement en corrosion d’un câble constitué de ces mêmes fils. La géométrie du produit final est un paramètre du 1er ordre. Enfin, le comportement en corrosion d’un assemblage entre un câble en alliage AA1370 et une pièce de connectique en cuivre pur a été étudié à l’aide de techniques de microscopie et d’électrochimie locale afin d’identifier les processus de corrosion mis en jeu lors du couplage galvanique Al/Cu en prenant en compte la géométrie particulière de l’assemblage. L’influence de l’agressivité du milieu sur la durabilité de ces assemblages a été étudiée en combinant l’ensemble des résultats avec ceux obtenus lors d’essais de corrosion industriels. L’étude dans son ensemble a permis de générer des avancées significatives dans la compréhension des mécanismes de corrosion à l’échelle de l’alliage AA1370 sélectionné mais également à l’échelle de l’assemblage. / This work was performed in the framework of a technological development program with LEONI. The aim of this research program was to provide technical skills and scientific knowledge on the durability in automotive harness environment of a wiring harness; it was focused on the corrosion behavior of an assembly between a AA1370 wire and pure Cu connector. Automotive wires are constituted of small diameter strands which are manufactured following a multistep forming process. Thus, the first objective of this work was to analyze the influence of each step of the forming process on the corrosion behavior of AA1370 alloy. The results show that a « microstructural parameters – corrosion resistance » relationship can be established and must be taken into account in each step of the forming process of a AA1370 strand arm. Then, the electrochemical processes occurring when the wire was exposed to an aqueous environment were investigated using electrochemical impedance measurements. The results show that the corrosion behavior of the wire was controlled by the formation of a confined electrolyte between the strand arms. Therefore the knowledge of the electrochemical processes occurring for AA1370 alloy strands was not sufficient to explain the corrosion behavior of a wire made of the same strands. The investigation of wire specific corrosion behavior showed the benefits to work with a representative geometry of the final product instead of testing single strand alone. Then, the corrosion behavior of the assembly between a AA1370 wire and pure Cu connector was also investigated coupling electrochemical measurements and microscope observations, to identify the corrosion processes involved during Al/Cu galvanic coupling, considering a representative geometry of the assembly. Finally, the results from laboratory tests were compared to those from industrials validation tests in order to study the influence of the environment aggressiveness on the assembly durability. The study led to significant advances in the understanding of the corrosion mechanisms at the alloy scale and also at the assembly scale.
2

Trvanlivost alkalicky aktivovaných systémů / Durability of alkali-activated systems

Šafář, Martin January 2015 (has links)
Alkali activated binders have the potential to become an alternative construction material to ordinary portland cement binders. This thesis concentrates on durability testing of alkali activated blast furnace slag and fly ash based concrete. The chosen aspects of durability included sulfate resistance, acid resistance, carbonation, freeze-thaw resistance, frost-salt resistance and porosity. Microstructural changes and formation of new crystalline phases were observed using XRD and SEM-EDX analysis. Potential application of the tested material from the durability point of view was evaluated by comparison with a reference ordinary portland cement based concrete.
3

Vývoj lepicí hmoty pro instalaci čedičových prvků na silikátový podklad v náročných expozičních podmínkách / Development of adhesive material for the installation of basalt elements on silicate foundations under severe exposure conditions

Bergerová, Kamila January 2019 (has links)
The diploma thesis deals with research and subsequent development of a new adhesive material for the installation of nonabsorbent basalt elements on silicate foundations under severe exposure conditions. For commercially produced tile adhesives, only primary raw materials are used as fillers. The purpose of this work is to evaluate the possibility of utilization of secondary raw materials as fillers in the tile adhesive. The thesis is mainly focused on the durability of these materials after exposure to the aggressive environment.

Page generated in 0.1095 seconds