Velocidades e frações de vazio em escoamentos ar-agua e ar-xantana, padrão pistonado, atraves de duto anular, com variação da inclinação

Andrade Junior, Paulo Hora de 17 April 1995 (has links)
Orientadores: Antonio Carlos Bannwart, Edson Yoshihito Nakagawa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-21T01:57:43Z (GMT). No. of bitstreams: 1 AndradeJunior_PauloHorade_M.pdf: 39117178 bytes, checksum: 0cf9d815238538a88d4db6a4c0f9cca4 (MD5) Previous issue date: 1995 / Resumo: Foi pesquisado o escoamento ascendente, concorrente, padrão pistonado de ar com água e de ar com goma xantana, através de duto de seção anular concêntrica, nas posições horizontal, vertical e em cinco outras inclinações. O objetivo foram as medição das velocidades das bolhas de Taylor e a comparação como modelo de Zuber & Findlay. Um aparato foi projetado e construído. Consiste de um trecho de 4,5 m de dutos, limitado por duas válvulas esfera, formando a seção de testes. Esta faz parte de um duto anular concêntrico de 9 m de comprimento, formado por um tubo exterior ("casing") com diâmetro interno de 77,2 mm e por um tubo interior ("tubing") com 42,2 mm de diâmetro externo O aparato pode ser inclinado e fixado em várias diferentes posições, de acordo com o ângulo desejado. As velocidades superficiais das fases líquida e gasosa, assim como as frações de vazio, são medidas e plotadas no gráfico de Zuber & Findlay. Os coeficientes angulares Co, oriundos das retas de ajuste, são expostos em função da inclinação e tais curvas são comparadas com algumas publicações. É testada também a correlação de Hewitt, para o cálculo da fração de vazio a partir das velocidades superficiais e das propriedades das fases. Foram usadas as mesmas faixas de velocidades superficiais, nos escoamentos ar-água e ar-xantana, em cada uma das inclinações, possibilitando assim, a comparação dos resultados e a observação da influência das propriedades reológicas. Os resultados obtidas na inclinação vertical são comparados com a correlação de Khatib & Richardson / Abstract: Air-water and air-Xanthum Gum mixture in upward co-current slug flow through concentric annuli are experimentally studied in horizontal, vertical and five other inclinations. The goal is the determination of Taylor bubble velocity using electrical resistivity sensors for direct measurements and quick-closing ball valves for indirect measurements. A flow system consisting of a 4,5 m long test section, limited by two ball valves was designed and built. It is part of a 9 m long concentric annulus with 77,2 mm inside diameter casing (external pipe) and 42,2 mm outside diameter tubing (internal pipe). The whole system can be fixed in several positions, according to the inclination angle desired. The superficial velocities for air and liquid phases are controlled, the volumetric void fractions are measured and the slug veiocities are calculated and plotted against the mixture superficial velocities and compared with Zuber & Findlay mode!. The slop coefficients Co, found by linear regressions, are studied as a function of the inclination and compared with other publications. Hewitt's correlation for the void fraction as a function of the superficial velocities and the fluid properties is tested. For each inclination angle, tests were run both with air-water and air-Xanthum Gum solution using the same superficial velocity ranges, for comparison purposes and identification of the influence of rheological properties. For vertical flow, Khatib & Richardson correlation is compared with the results / Mestrado / Mestre em Engenharia de Petróleo
2

Estudo experimental de escoamento multifásico em duto anular de grande diâmetro / Experimental study of multiphase flow in large annular duct

Colmanetti, Alex Roger Almeida 29 September 2016 (has links)
Escoamentos gás-líquido assim como escoamento líquido-líquido-gás em duto de geometria anular estão presentes em muitas aplicações industriais, por exemplo, em poços de petróleo direcionais. No entanto, até mesmo características globais de escoamento gás-líquido nessa geometria, como os padrões de escoamento ou gradiente de pressão, não são ainda totalmente compreendidas. E ainda, informações são escassas quando se refere a escoamento trifásico nessa geometria, cuja aplicação está relacionada ao fenômeno de inversão de fase, que é de extrema importância não apenas para ao setor petrolífero, como para a indústria alimentícia. O presente estudo experimental tem como objetivo avaliar o escoamento líquido-gás, apresentar dados inéditos de escoamento gás-líquido para três viscosidades de óleo, além de avaliar o fenômeno de inversão de fase em escoamento ascendente vertical em duto anular de grande diâmetro. Um aparato experimental inclinável com 10,5 m de comprimento foi projetado e construído para este trabalho. As dimensões radiais do duto anular estão em escala real, conforme se verifica em poços de petróleo e gás. A investigação em escoamento gás-líquido foi conduzida utilizando água, óleo e ar comprimido como fluidos de trabalho em escoamento ascendente vertical em duas geometrias: (i) um tubo com diâmetro de 95 mm e (ii) um duto de configuração anular e concêntrico, com diâmetro hidráulico de valor igual ao diâmetro do tubo. A avaliação do fenômeno de inversão de fase em escoamento trifásico foi conduzida em condições equivalentes em três geometrias: (i) tubo vertical menor com diâmetro de 50 mm, (ii) tubo com diâmetro de 95 mm e (iii) um duto anular concêntrico. Padrões de escoamento, queda de pressão e fração volumétrica de fase foram obtidos para ambos os escoamentos gás-líquido e líquido-líquido-gás. Os dados coletados nesse trabalho são de grande importância para o desenvolvimento de novas correlações de fechamento, que são essenciais para o projeto otimizado de poços de petróleo. Dados inéditos de escoamento bifásico óleo-gás são apresentados, bem como um estudo pioneiro em inversão de fase em escoamento trifásico com velocidade superficial de gás e viscosidade do óleo elevadas. / Two-phase flows as well as three-phase flow in annular geometry are present in many industrial applications, for example in oil directional wells. However, even global characteristics of gas-liquid flow in this geometry, such as flow patterns and pressure gradient are not fully understood. Moreover, information is scarce when it refers to three-phase flow in this geometry, which application is related to the phase inversion phenomenon, which is of extreme importance and not only for the oil industry. This experimental study aims to evaluate the liquid-gas flow, present new data from gas-liquid flow for three oil viscosities and evaluate the phase inversion phenomenon in vertical upward flow in large diameter annular duct. An experimental apparatus with 10.5 m length was designed and built for this work. The radial dimensions of the annular duct are similar to full scale, as observed in oil and gas wells. The investigation into gas-liquid flow was conducted using water, oil and compressed air as working fluids in an ascending vertical flow in two geometries: (i) a tube with 95 mm diameter and (ii) a concentric annular duct with hydraulic diameter equivalent to the tube internal diameter. The evaluation of the phase inversion phenomenon in three-phase flow was conducted under equivalent conditions for three geometries: (i) smaller vertical tube with 50 mm of internal diameter, (ii) tube with 95 mm of internal diameter and (iii) concentric annular duct with hydraulic diameter of 95 mm. Flow patterns, pressure drop and volumetric phase fraction were obtained for both gas-liquid and gas-liquid-liquid flows. The data collected in this study are of great importance for the development of new closing correlations, which are essential for the optimized design of oil wells. New two-phase flow data for three oil viscosities, not found in the literature, are presented as well as a pioneer study in three-phase-flow phase inversion with high oil viscosity and high superficial gas velocity.
3

Estudo experimental de escoamento multifásico em duto anular de grande diâmetro / Experimental study of multiphase flow in large annular duct

Alex Roger Almeida Colmanetti 29 September 2016 (has links)
Escoamentos gás-líquido assim como escoamento líquido-líquido-gás em duto de geometria anular estão presentes em muitas aplicações industriais, por exemplo, em poços de petróleo direcionais. No entanto, até mesmo características globais de escoamento gás-líquido nessa geometria, como os padrões de escoamento ou gradiente de pressão, não são ainda totalmente compreendidas. E ainda, informações são escassas quando se refere a escoamento trifásico nessa geometria, cuja aplicação está relacionada ao fenômeno de inversão de fase, que é de extrema importância não apenas para ao setor petrolífero, como para a indústria alimentícia. O presente estudo experimental tem como objetivo avaliar o escoamento líquido-gás, apresentar dados inéditos de escoamento gás-líquido para três viscosidades de óleo, além de avaliar o fenômeno de inversão de fase em escoamento ascendente vertical em duto anular de grande diâmetro. Um aparato experimental inclinável com 10,5 m de comprimento foi projetado e construído para este trabalho. As dimensões radiais do duto anular estão em escala real, conforme se verifica em poços de petróleo e gás. A investigação em escoamento gás-líquido foi conduzida utilizando água, óleo e ar comprimido como fluidos de trabalho em escoamento ascendente vertical em duas geometrias: (i) um tubo com diâmetro de 95 mm e (ii) um duto de configuração anular e concêntrico, com diâmetro hidráulico de valor igual ao diâmetro do tubo. A avaliação do fenômeno de inversão de fase em escoamento trifásico foi conduzida em condições equivalentes em três geometrias: (i) tubo vertical menor com diâmetro de 50 mm, (ii) tubo com diâmetro de 95 mm e (iii) um duto anular concêntrico. Padrões de escoamento, queda de pressão e fração volumétrica de fase foram obtidos para ambos os escoamentos gás-líquido e líquido-líquido-gás. Os dados coletados nesse trabalho são de grande importância para o desenvolvimento de novas correlações de fechamento, que são essenciais para o projeto otimizado de poços de petróleo. Dados inéditos de escoamento bifásico óleo-gás são apresentados, bem como um estudo pioneiro em inversão de fase em escoamento trifásico com velocidade superficial de gás e viscosidade do óleo elevadas. / Two-phase flows as well as three-phase flow in annular geometry are present in many industrial applications, for example in oil directional wells. However, even global characteristics of gas-liquid flow in this geometry, such as flow patterns and pressure gradient are not fully understood. Moreover, information is scarce when it refers to three-phase flow in this geometry, which application is related to the phase inversion phenomenon, which is of extreme importance and not only for the oil industry. This experimental study aims to evaluate the liquid-gas flow, present new data from gas-liquid flow for three oil viscosities and evaluate the phase inversion phenomenon in vertical upward flow in large diameter annular duct. An experimental apparatus with 10.5 m length was designed and built for this work. The radial dimensions of the annular duct are similar to full scale, as observed in oil and gas wells. The investigation into gas-liquid flow was conducted using water, oil and compressed air as working fluids in an ascending vertical flow in two geometries: (i) a tube with 95 mm diameter and (ii) a concentric annular duct with hydraulic diameter equivalent to the tube internal diameter. The evaluation of the phase inversion phenomenon in three-phase flow was conducted under equivalent conditions for three geometries: (i) smaller vertical tube with 50 mm of internal diameter, (ii) tube with 95 mm of internal diameter and (iii) concentric annular duct with hydraulic diameter of 95 mm. Flow patterns, pressure drop and volumetric phase fraction were obtained for both gas-liquid and gas-liquid-liquid flows. The data collected in this study are of great importance for the development of new closing correlations, which are essential for the optimized design of oil wells. New two-phase flow data for three oil viscosities, not found in the literature, are presented as well as a pioneer study in three-phase-flow phase inversion with high oil viscosity and high superficial gas velocity.
4

Modelo de mistura aplicado para a previsão de Holdup e gradiente de pressão bifásico em duto anular de grande diâmetro / Drift-flux model applied to predict holdup and two-phase pressure gradient in large annular duct

Carvalho, Sávider Conti 21 March 2013 (has links)
O escoamento bifásico é muito importante para vários ramos industriais. As misturas bifásicas podem escoar em diversas configurações, as quais são chamadas de padrões de escoamento, e que, ao longo dos anos, receberam diversas classificações. Neste trabalho foi estudado o padrão bolhas dispersas em duto anular. Os trabalhos sobre escoamento bifásico em geometria anular são mais escassos, especialmente quando se trata de dutos anulares de grande dimensão. Dentre os modelos existentes para a modelagem do escoamento bifásico, trabalhamos com o modelo de mistura (Drift Flux), pois, apesar das altas velocidades superficiais, o escoamento em bolhas não possui um comportamento homogêneo, já que a fase gasosa ainda escoa na região central e com uma velocidade maior do que a velocidade da mistura. Foi utilizado o modelo de mistura unidimensional para a modelagem do escoamento bifásico água-ar, pois, além de bastante preciso, é de baixo custo computacional e fácil implementação. Neste trabalho empregamos, a princípio, equações elaboradas para dutos circulares, as quais foram adaptadas para a geometria anular fazendo-se uso do conceito de diâmetro hidráulico. As equações foram implementadas no software Mathematica® e as previsões para o holdup e queda de pressão foram comparadas com dados experimentais próprios. O trabalho experimental foi realizado no laboratório de escoamentos multifásicos do Núcleo de Engenharia Térmica e de Fluidos (NETeF) da EESC-USP, o qual conta com uma instalação experimental em estado operacional para a simulação de escoamentos bifásicos vertical e inclinados em duto anular. Foram colhidas medidas de holdup e queda de pressão bifásica. A concordância entre os dados experimentais e as previsões foi muito satisfatória. / Two-phase flow is present in a wide range of industrial processes. Such flows occur in many geometrical configurations known as flow patterns. In this work is presented a study about bubbly flow in annular duct. Works on two-phase flow in large annular geometry are very scarce. Among the existing models for modeling two-phase flow we chose the drift flux model because the bubbly flow does not behave as a homogeneous mixture, despite of the high superficial velocities, since the gas phase flows faster in the core region in comparison with the mixture velocity. The onedimensional drift flux model besides to be accurate is of low computational cost and easy implementation. The goal of this work is to analyze the prediction of holdup and pressure drop in annular ducts of large diameter. The set of equations used was adapted from those of circular ducts by using the hydraulic diameter concept. The equations were implemented in Mathematica software and holdup and pressure drop prediction were compared with experimental data taken in the experimental facility of the Thermal-fluids Engineering Laboratory of EESC-USP. It was collected measure of holdup and pressure drop. The agreement between experimental data and model predictions is encouraging.
5

Modelo de mistura aplicado para a previsão de Holdup e gradiente de pressão bifásico em duto anular de grande diâmetro / Drift-flux model applied to predict holdup and two-phase pressure gradient in large annular duct

Sávider Conti Carvalho 21 March 2013 (has links)
O escoamento bifásico é muito importante para vários ramos industriais. As misturas bifásicas podem escoar em diversas configurações, as quais são chamadas de padrões de escoamento, e que, ao longo dos anos, receberam diversas classificações. Neste trabalho foi estudado o padrão bolhas dispersas em duto anular. Os trabalhos sobre escoamento bifásico em geometria anular são mais escassos, especialmente quando se trata de dutos anulares de grande dimensão. Dentre os modelos existentes para a modelagem do escoamento bifásico, trabalhamos com o modelo de mistura (Drift Flux), pois, apesar das altas velocidades superficiais, o escoamento em bolhas não possui um comportamento homogêneo, já que a fase gasosa ainda escoa na região central e com uma velocidade maior do que a velocidade da mistura. Foi utilizado o modelo de mistura unidimensional para a modelagem do escoamento bifásico água-ar, pois, além de bastante preciso, é de baixo custo computacional e fácil implementação. Neste trabalho empregamos, a princípio, equações elaboradas para dutos circulares, as quais foram adaptadas para a geometria anular fazendo-se uso do conceito de diâmetro hidráulico. As equações foram implementadas no software Mathematica® e as previsões para o holdup e queda de pressão foram comparadas com dados experimentais próprios. O trabalho experimental foi realizado no laboratório de escoamentos multifásicos do Núcleo de Engenharia Térmica e de Fluidos (NETeF) da EESC-USP, o qual conta com uma instalação experimental em estado operacional para a simulação de escoamentos bifásicos vertical e inclinados em duto anular. Foram colhidas medidas de holdup e queda de pressão bifásica. A concordância entre os dados experimentais e as previsões foi muito satisfatória. / Two-phase flow is present in a wide range of industrial processes. Such flows occur in many geometrical configurations known as flow patterns. In this work is presented a study about bubbly flow in annular duct. Works on two-phase flow in large annular geometry are very scarce. Among the existing models for modeling two-phase flow we chose the drift flux model because the bubbly flow does not behave as a homogeneous mixture, despite of the high superficial velocities, since the gas phase flows faster in the core region in comparison with the mixture velocity. The onedimensional drift flux model besides to be accurate is of low computational cost and easy implementation. The goal of this work is to analyze the prediction of holdup and pressure drop in annular ducts of large diameter. The set of equations used was adapted from those of circular ducts by using the hydraulic diameter concept. The equations were implemented in Mathematica software and holdup and pressure drop prediction were compared with experimental data taken in the experimental facility of the Thermal-fluids Engineering Laboratory of EESC-USP. It was collected measure of holdup and pressure drop. The agreement between experimental data and model predictions is encouraging.
6

Estudo experimental, simulação numérica e modelagem fenomenológica da separação gravitacional de gás no fundo de poços direcionais / Experimental study, numerical simulation and phenomenological modeling of gravitational separation of gas in down-hole directional wells

Mendes, Fernando Augusto Alves 30 August 2012 (has links)
Propõe-se o estudo do separador gravitacional de fundo de poço do tipo shroud invertido para poços direcionais e horizontais. A geometria inovadora é observada pela inclinação imposta, solução que transforma um escoamento vertical descendente, veloz e caótico, num escoamento inclinado e segregado em canal livre. Com a inclinação, minimizasse a incorporação de gás, no impacto do escoamento em superfície livre contra a interface de líquido formada pelo nível do anular interno (NAI), e a segregação é incrementada devido ao gradiente de velocidades e ao aparecimento da componente da gravidade na direção radial do poço de petróleo. O trabalho experimental tem como uma de suas metas o levantamento da eficiência de separação em função das vazões de líquido e gás, do ângulo de inclinação e o grau de interferência do escoamento no duto anular formado entre o separador e a parede do poço de petróleo, chamado neste trabalho de anular externo. Foi feito um trabalho de semelhança dimensional e foram detectados os números adimensionais pertinentes ao problema. Constatou-se que a vazão de gás e o escoamento no anular externo não interferem na eficiência de separação. Além disso, foi realizado um trabalho de caracterização dos padrões do escoamento gás-líquido em duto anular, através de visualização e análise no domínio do tempo e da frequência do sinal dinâmico da queda de pressão. Também são propostos dois modelos matemáticos, um modelo fenomenológico baseado em princípios físicos fundamentais, que foi capaz de prever com eficácia a região de máxima eficiência do separador shroud invertido, e um modelo numérico, que reproduziu a fenomenologia do processo de separação do gás. / This research project proposes the study of the inverted-shroud gravitational gas separator for directional and horizontal wells. The innovative geometry is observed by the inclination that transforms a vertical, fast and chaotic downward flow into an inclined and segregated free channel flow. Due to inclination, the incorporation of gas at the internal gasliquid interface (NAI) is minimized; the segregation is increased due to the velocity gradient and the gravitational term that arises in the radial direction of the oil well. One of the aims of the experimental work is the obtaining of new data of gas separation efficiency as a function of the flow of liquid and gas, inclination angle and the evaluation of the degree of interference of the external annular duct flow. A dimensional analysis was undertaken to identify the relevant dimensionless numbers. It was found that the gas flow and the flow pattern in the external annular duct do not interfere in the separation efficiency. A flow pattern characterization was carried out through visualization and time and frequency domain analysis of differential pressure signature signal. Two mathematical models are proposed, a phenomenological model based on fundamental physical principles, which was able to predict with good accuracy the region of maximum separation efficiency, and a numerical model, which reproduced the phenomenology of the gas separation process.
7

Investigação da distribuição de tamanho de bolhas em um separador gás-líquido do tipo shroud invertido / Investigation of bubble-diameter distribution in a gas-liquid inverted-shroud separator

Barbosa, Marcel Cavallini 13 November 2015 (has links)
Operações de produção de petróleo, que utilizam sistemas de bombeamento centrífugo submerso, constantemente encontram a presença de gás livre nos poços, o que pode gerar ou agravar problemas como cavitação e falhas dinâmicas, quando o gás é succionado pela bomba. O separador gravitacional do tipo shroud invertido é uma solução possível para este problema nos casos de operação em poços direcionais de petróleo. O trabalho tem como objetivo apresentar um estudo do diâmetro das bolhas que ocorrem no interior de um separador gravitacional gás-líquido do tipo shroud invertido. A finalidade é o aprimoramento de um modelo fenomenológico do funcionamento deste tipo de separador, aplicado à indústria petrolífera, sendo que o modelo fenomenológico garante total separação de gás, fornecidas determinadas condições. O modelo prevê, através do cálculo da energia cinética turbulenta, o tamanho médio das bolhas carregadas para o seio do líquido por aeração no duto anular. Partindo de estudos anteriores, uma verificação do modelo fenomenológico foi feita utilizando um aparato experimental com misturas bifásicas ar-água e ar-óleo em três diferentes inclinações. O aparato possui dimensões radiais reais de um poço de petróleo offshore. Foi utilizado um sensor 3D ORM para a medição do tamanho médio (sauter) das bolhas arrastadas pelo líquido até a entrada do tubo de produção, em diversas combinações de vazões da mistura água-ar. Esta medição permite o ajuste das correlações que regem o modelo fenomenológico, no que diz respeito às equações dependentes do diâmetro teórico de bolhas arrastadas pela fase líquida. As descobertas provenientes deste estudo foram implementadas em um código computacional que será utilizado pela PETROBRAS, financiadora do projeto, para suas operações de bombeamento. / Oil mining operations powered by centrifugal submersible pumping systems suffer constant setbacks due to the presence of free gas in wells. Decompression in the reservoir liberates this gas in the form of bubbles that, upon reaching the suction end of the pump, cause cavitation and dynamic failures resulting in production and equipment losses. The Inverted-shroud gravitational separator is a possible solution to this problem. This work presents a study on diameters of bubbles that occur inside this separator. The goal is the improvement of the understanding of this kind of separator as well as the enhancement of a previously reported phenomenological model, which ensures total gas separation when the separator is installed in directional wells and under specific operational conditions. Empirically adjusted correlations are used to ensure that all entrained bubbles do not reach the pump. The model was tested for two-phase flows of water-air and oil-air mixtures using three different inclinations. Tests were performed with an experimental apparatus that simulates a pilot-scale well casing with an inverted-shroud separator installed. A 3D ORM particle-size sensor was employed in order to measure the average (sauter) diameter of entrained bubbles that are dragged by the liquid flow towards the end of the production tube. This investigation will be used to improve the reliability of the phenomenological model and reduce its dependency on a theoretical prediction of the bubble size. The findings were incorporated to the final version of an in-house gas separator design software developed at the request of PETROBRAS, the project funder and Inverted-shroud patent holder, for usage on its oil mining operations.
8

Separação gravitacional de gás em um duto anular inclinado: estudo experimental e modelagem fenomenológica / Gravitational gas separation in an inclined annular channel: experimental study and phenomenological modeling

Vidal, Luis Enrique Ortiz 22 April 2010 (has links)
O presente trabalho apresenta um estudo associado à separação de gás para escoamento gás-líquido em um duto anular inclinado. Esse tipo de escoamento e geometria são encontrados em separadores de gás do tipo shroud invertido na indústria de petróleo quando utilizadas técnicas de bombeamento para a exploração de poços. A presença de gás livre a montante da bomba é uma das maiores limitações dos sistemas de bombeamento, por acarretar cavitação e falhas dinâmicas nos equipamentos. O presente estudo tem por objetivo garantir a separação total de gás livre a montante da bomba através da proposição de um separador do tipo shroud invertido em tubulação inclinada para aplicação na exploração de petróleo em poços direcionais. Um estudo experimental com ar e água como fluidos de trabalho a pressão quase atmosférica foi desenvolvido visando a compreensão da fenomenologia do separador shroud invertido. Foram observados escoamentos em duto anular do tipo: bifásico gás-líquido ascendente, monofásico em canal livre e bifásico gás-líquido descendente devido ao fenômeno de aeração; foram coletados também dados de eficiência de separação em função do ângulo de inclinação, vazão do líquido e queda de pressão entre o shroud e a saída do tubo de produção. Encontrou-se uma variável de extrema importância no fenômeno de separação até agora não reportada na literatura: o nível do anular interno do shroud (NAI). Um modelo fenomenológico que prevê a separação total do gás foi desenvolvido a partir da interpretação dos fenômenos físicos observados experimentalmente. Uma correlação inédita para a modelagem do fenômeno de dissipação de energia cinética turbulenta vinculado à separação do gás é proposta. O modelo foi validado qualitativamente com dados da literatura e ajustado com os dados coletados neste trabalho, mostrando boa concordância. / This paper presents a study associated with gas separation in an inclined gas-liquid annular-duct flow. This type of flow and geometry are found in shroud-inverted gas separators applied to petroleum industries when using pumping technique for oil production. High void fraction at the pump suction of is one of the most important limitations of the SCP technique, causing cavitation and dynamics failures in the equipment. The present study aims to provide a solution for the total gas separation through the use of an innovative inclined inverted-shroud separator for directional wells. An experimental study, where air and water at near atmospheric pressure constituted the working fluids, was carried out to understand the phenomenology of the inclined inverted-shroud separator. Different annular-duct flows were observed: upward gas-liquid flow, single-phase open channel flow, downward gas-liquid flow due to the phenomenon of aeration; also new data of separation efficiency were collected as a function of inclination angle, liquid flow rate and pressure drop between the shroud and production pipe outlet. One of the most significant findings is that the liquid level of the inner annular channel (NAI) of the shroud is a very important variable in the phenomenon of separation; so far this was not reported in the literature. Based on the observations, a phenomenological model that predicts total gas separation is proposed. A new correlation for the modeling of the dissipation of turbulent kinetic energy associated with the gas separation is presented. The model was qualitatively compared with available data from the literature and quantitatively adjusted against the new experimental data obtained in this work, and the agreement was quite good.
9

Separação gravitacional de gás em um duto anular inclinado: estudo experimental e modelagem fenomenológica / Gravitational gas separation in an inclined annular channel: experimental study and phenomenological modeling

Luis Enrique Ortiz Vidal 22 April 2010 (has links)
O presente trabalho apresenta um estudo associado à separação de gás para escoamento gás-líquido em um duto anular inclinado. Esse tipo de escoamento e geometria são encontrados em separadores de gás do tipo shroud invertido na indústria de petróleo quando utilizadas técnicas de bombeamento para a exploração de poços. A presença de gás livre a montante da bomba é uma das maiores limitações dos sistemas de bombeamento, por acarretar cavitação e falhas dinâmicas nos equipamentos. O presente estudo tem por objetivo garantir a separação total de gás livre a montante da bomba através da proposição de um separador do tipo shroud invertido em tubulação inclinada para aplicação na exploração de petróleo em poços direcionais. Um estudo experimental com ar e água como fluidos de trabalho a pressão quase atmosférica foi desenvolvido visando a compreensão da fenomenologia do separador shroud invertido. Foram observados escoamentos em duto anular do tipo: bifásico gás-líquido ascendente, monofásico em canal livre e bifásico gás-líquido descendente devido ao fenômeno de aeração; foram coletados também dados de eficiência de separação em função do ângulo de inclinação, vazão do líquido e queda de pressão entre o shroud e a saída do tubo de produção. Encontrou-se uma variável de extrema importância no fenômeno de separação até agora não reportada na literatura: o nível do anular interno do shroud (NAI). Um modelo fenomenológico que prevê a separação total do gás foi desenvolvido a partir da interpretação dos fenômenos físicos observados experimentalmente. Uma correlação inédita para a modelagem do fenômeno de dissipação de energia cinética turbulenta vinculado à separação do gás é proposta. O modelo foi validado qualitativamente com dados da literatura e ajustado com os dados coletados neste trabalho, mostrando boa concordância. / This paper presents a study associated with gas separation in an inclined gas-liquid annular-duct flow. This type of flow and geometry are found in shroud-inverted gas separators applied to petroleum industries when using pumping technique for oil production. High void fraction at the pump suction of is one of the most important limitations of the SCP technique, causing cavitation and dynamics failures in the equipment. The present study aims to provide a solution for the total gas separation through the use of an innovative inclined inverted-shroud separator for directional wells. An experimental study, where air and water at near atmospheric pressure constituted the working fluids, was carried out to understand the phenomenology of the inclined inverted-shroud separator. Different annular-duct flows were observed: upward gas-liquid flow, single-phase open channel flow, downward gas-liquid flow due to the phenomenon of aeration; also new data of separation efficiency were collected as a function of inclination angle, liquid flow rate and pressure drop between the shroud and production pipe outlet. One of the most significant findings is that the liquid level of the inner annular channel (NAI) of the shroud is a very important variable in the phenomenon of separation; so far this was not reported in the literature. Based on the observations, a phenomenological model that predicts total gas separation is proposed. A new correlation for the modeling of the dissipation of turbulent kinetic energy associated with the gas separation is presented. The model was qualitatively compared with available data from the literature and quantitatively adjusted against the new experimental data obtained in this work, and the agreement was quite good.
10

Estudo experimental, simulação numérica e modelagem fenomenológica da separação gravitacional de gás no fundo de poços direcionais / Experimental study, numerical simulation and phenomenological modeling of gravitational separation of gas in down-hole directional wells

Fernando Augusto Alves Mendes 30 August 2012 (has links)
Propõe-se o estudo do separador gravitacional de fundo de poço do tipo shroud invertido para poços direcionais e horizontais. A geometria inovadora é observada pela inclinação imposta, solução que transforma um escoamento vertical descendente, veloz e caótico, num escoamento inclinado e segregado em canal livre. Com a inclinação, minimizasse a incorporação de gás, no impacto do escoamento em superfície livre contra a interface de líquido formada pelo nível do anular interno (NAI), e a segregação é incrementada devido ao gradiente de velocidades e ao aparecimento da componente da gravidade na direção radial do poço de petróleo. O trabalho experimental tem como uma de suas metas o levantamento da eficiência de separação em função das vazões de líquido e gás, do ângulo de inclinação e o grau de interferência do escoamento no duto anular formado entre o separador e a parede do poço de petróleo, chamado neste trabalho de anular externo. Foi feito um trabalho de semelhança dimensional e foram detectados os números adimensionais pertinentes ao problema. Constatou-se que a vazão de gás e o escoamento no anular externo não interferem na eficiência de separação. Além disso, foi realizado um trabalho de caracterização dos padrões do escoamento gás-líquido em duto anular, através de visualização e análise no domínio do tempo e da frequência do sinal dinâmico da queda de pressão. Também são propostos dois modelos matemáticos, um modelo fenomenológico baseado em princípios físicos fundamentais, que foi capaz de prever com eficácia a região de máxima eficiência do separador shroud invertido, e um modelo numérico, que reproduziu a fenomenologia do processo de separação do gás. / This research project proposes the study of the inverted-shroud gravitational gas separator for directional and horizontal wells. The innovative geometry is observed by the inclination that transforms a vertical, fast and chaotic downward flow into an inclined and segregated free channel flow. Due to inclination, the incorporation of gas at the internal gasliquid interface (NAI) is minimized; the segregation is increased due to the velocity gradient and the gravitational term that arises in the radial direction of the oil well. One of the aims of the experimental work is the obtaining of new data of gas separation efficiency as a function of the flow of liquid and gas, inclination angle and the evaluation of the degree of interference of the external annular duct flow. A dimensional analysis was undertaken to identify the relevant dimensionless numbers. It was found that the gas flow and the flow pattern in the external annular duct do not interfere in the separation efficiency. A flow pattern characterization was carried out through visualization and time and frequency domain analysis of differential pressure signature signal. Two mathematical models are proposed, a phenomenological model based on fundamental physical principles, which was able to predict with good accuracy the region of maximum separation efficiency, and a numerical model, which reproduced the phenomenology of the gas separation process.