• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Årsvärmefaktor för bergvärmepumpar i Norden : En undersökande studie av prestanda enligt EU:s standard för energimärkning / Seasonal Performance Factor for ground source heat pumps in Scandinavia : An investigative study of performance according to the energy labeling standard

Kvist, Jessica January 2018 (has links)
Europeiska Unionen, EU, har som mål att år 2020 skall minst 20 % av energianvändningen i medlemsstaterna vara från förnyelsebar energi. En stor del av energianvändningen idag är för uppvärmning av hus och vatten. Samtidigt som allt sker strålar solen energirika strålar mot jordklotet. En metod för uppvärmning är att använda en bergvärmepump. Bergvärmepumpen kräver el till sin kompressor. För en energieffektiv samt god lösning ur ett förnyelsebart energi-perspektiv kan bergvärmepumpen drivas av el som genererats från solceller. Idag redovisas bergvärmepumpars effektivitet med nyckeltalen SCOP och hwh som visar hur effektivt bergvärmepumpen jobbar när den tillgodoser rumsuppvärmningsbehov respektive varmvattenberedning. Årsvärmefaktorn är en kombination av dessa två. SCOP och hwh beräknas idag enligt en 4 stycken standarder som EU framtagit. För att värmepumpsleverantörer ska få sälja bergvärmepumpar inom EU måste de ha beräknat SCOP och hwh enligt dessa standarder. Standarderna utgår från relativt konstanta yttre förutsättningar. Denna studien ska undersöka hur årsvärmefaktorn påverkas då dessa yttre förutsättningar varierar. Faktorerna som kommer undersökas är framledningstemperatur, tappvarmvattensbehov, dimensionerande värmebehov och geografisk placering. Resultatet visar att samtliga av de undersökta faktorerna har mer eller mindre en påverkan på årsvärmefaktorn. I en undersökning på en bergvärmepump var årsvärmefaktorn 4,5 för den systemlösning som standarden går efter. För samma bergvärmepump men med varierade yttre förutsättningar kunde årsvärmefaktorn variera mellan 1,2 till 6,3. Systemlösningen med den årsvärmefaktor 1,2 hade i förhållande till standardens systemlösning högre tappvarmvattensbehov samt var underdimensionerad. Systemlösningen med årsvärmefaktor 6,3 hade i förhållande till standardens systemlösning inget tappvarmvattensbehov, var överdimensionerad, hade lägre framledningstemperatur samt var placerad på en ort med kallare klimat. Resultatet tyder på att tappvarmvattensbehovet har den största påverkan på årsvärmefaktorn. / The European Union, EU, aims to achieve a minimum of 20% renewable energy. A large share of the energy use today is for the heating of houses and water, while at the same time, the sun provides a steady supply of energy-rich sunrays. A method for heating is to use a heat pump, which requires electricity for its compressor. In an energy efficient and sustainable solution, the heat pump could be driven by electricity generated by solar panels. Heat pumps performances are measured by the key value; annual heat factor. The annual heat factor indicates the total efficiency of the heat pump measured over the whole year. Today, the efficiency of heat pumps is indicated by the use of two key values; SCOP and hwh, which respectively shows the efficiency of the heat pump while fulfilling the room heating requirement and the DHW requirement. The annual heating factor is a combination of these key values. SCOP and hwh are calculated according to four standards developed by the EU. In order to be able to sell heat pumps, manufacturers in the EU have to follow these standards for calculating SCOP and hwh.  The standards assume relatively constant external conditions. This study investigates how the annual heating factor is affected when these external conditions are allowed to vary. The factors that will be investigated are the temperature of the flow line temperature, domestic hot water needs, dimensioning heating demand and geographic location. The results present that all of the investigated factors more or less affects the annual heating factor. In one investigation of a ground source heat pump the annual heating factor was 4,5 for the system solution that was based on the standard calculations. For the same heat pump but with external conditions that were allowed to vary the annual heating factor was estimated to vary between 1,2 and 6,3. The system solution with the annual heating factor of 1,2 had in relation to the EU standard system solution a larger domestic water demand and it was undersized. The system solution with an annual heating factor of 6,3 had in relation to the EU standard system solution no domestic water demand, was oversized, had a lower flow line temperature and was placed in a colder climate. The results imply that the domestic water demand has the biggest impact on the annual heating factor.
2

Automated Control System for Dust Concentration Measurements Using European Standard Reference Method / Design och implementation av regulator förbestämning av masskoncentrationer av stoft enligt europeiskstandard

Marstorp, Gustav January 2021 (has links)
Most companies that have any type of combustion or other pollution process via emission to air needs to measure their emissions to ensure they are within legal boundaries. Among the different types of pollution measurements, one of the most common is dust concentration, also known as particle concentration. An important factor in dust concentration measurements is to ensure that the concentration of the measured dust is representative to the dust concentration in the emissions. This is measured in isokinetic deviation, defined as (vn 􀀀 vd)=vd, where vn is the velocity in the entry nozzle and vd the velocity in the duct. Methods of dust concentration measurements used today are dependent on manual tuning and sensor readings, and the isokinetic deviation is calculated after a test. The focus of this project was therefore to investigate how the process of dust concentration measurements using standard reference methods could be automated in the way that isokinetic sampling is controlled and regulated by an automated control system in real time. Pressures, temperatures and sampled gas volume were quantized. A PIDcontroller was designed, implemented and tested. The PID-controller took the differential pressure between the inside of the entry nozzle and the duct, called zero pressure, as input. The system was tested in a laboratory environment by letting a radial fan create a flow, and thus create a zero pressure of -60 Pa, meaning that the pressure in the duct was 60 Pa greater than the pressure inside the entry nozzle. The PID-controller was then enabled and ran for five minutes. The result showed that the PID-controller managed to control the system to the reference point in less than 50 seconds for entry nozzles of diameters 6 mm, 8 mm, 10 mm and 12 mm. The results of the isokinetic deviations were -12 %, -5 %, -6 % and -4 % for entry nozzles with diameters 6 mm, 8 mm, 10 mm and 12 mm respectively. This is higher than the accepted values according to the European standard, which allows deviations in the interval -5%to 15%. However, these tests ran for relatively short time periods and started with large deviations which made it difficult to reach an isokinetic deviaiton in the accepted interval. Possible improvements could be to include the real time isokinetic deviation in the PID-controller, this would make it possible to change the reference value of the zero pressure in real time and guarantee isokinetic deviations in the accepted interval, even in extraordinary situations. / EU-regler ställer krav på anläggningar att kontrollera och begränsa sina utsläpp av stoft enligt EU standard 13284-1:2017. Vid en stoftmätning måste det tas hänsyn till många parametrar, där en av de viktigaste parametrarna är att provtagningen ska utföras isokinetiskt. Isokinetisk provtagning innebär att hastigheten i kanalen (skorstenen) är samma som i sonden där provgasen sugs ut. Dagens metoder för stoftmätning förlitar sig på manuella inställningar och den isokinetiska avvikelsen beräknas efter ett test. Det resulterade i frågeställnigen hur en automatiserad metod för bestämning av masskoncentration av stoft kan utformas så att den isokinetiska avvikelsen beräknas i realtid. Tryck, temperatur och gasvolym kvantiserades från analoga sensorer och kommunicerades till en mikrokontroller med det seriella protokollet I2C. En PID-reglator designades, implementerades och testades. PID-regulatorn tog tryckskillnaden mellan kanal och sond som insignal. Utsignalen från PID-regulatorn var en spänning som via en motordriven ventil kontrollerade inflödet i munstycket. Systemet testades i laborativ miljö genom att låta en fläkt skapa ett flöde tills den uppmätta tryckskillnaden mellan sond och kanal var -60 Pa. Därefter aktiverades PID-regulatorn och testet pågick sedan i fem minuter. Testet utfördes för munstycken med diameterna 6 mm, 8 mm, 10 mm och 12 mm. Resultatet visade att PID-regulatorn styrde systemet till referenspunkten på mindre än 50 sekunder för samtliga diametrar på munstyckena. De isokinetiska avvikelserna (skillnaden i hastighet mellan munstycke och kanal) beräknades till -12 %, -5 %, -6 % och -4 % för munstyckena 6 mm, 8 mm, 10 mm och 12 mm. I två av fallen var det högre än det accepterade värdet enligt EU standarden som tillåter avvikelser inom intervallet -5 % till 15 %. Det kan förklaras av att testen utfördes under en relativ kort tidsperiod och startades med stora avvikelser. Regulatorn skulle dock kunna förbättras genom att använda testets aktuella isokinetiska avvikelse och med den informationen bestämma systemets referenspunkt. Det skulle göra det möjligt att kompensera för tidigare avvikelser och på det sättet uppnå isokinetiska avvikelser inom tillåtet intervall även för extremfall.

Page generated in 0.0337 seconds