• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 61
  • 7
  • Tagged with
  • 68
  • 68
  • 48
  • 41
  • 37
  • 20
  • 20
  • 18
  • 14
  • 14
  • 14
  • 12
  • 10
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Modélisation du comportement de l'azote dans un système de traitement individuel d'épuration

Bernier, Jean 16 April 2018 (has links)
L'objectif de ce travail est d'étudier et de modéliser le comportement de l'azote pour un procédé de traitement résidentiel d'eau usée. Une unité pilote d'un système BionestMD traitant des eaux grises et noires installée dans les locaux de la compagnie produisant le procédé a été étudiée. Celle-ci comportait une fosse septique ainsi qu'un réacteur biologique à support fixe, dont une partie est aérée. La sortie de ce réacteur était en partie recirculée vers l'entrée de la fosse. Un suivi sur plusieurs semaines de plusieurs paramètres (DCO, NH₃/NH₄⁺, O₂...) a été effectué quotidiennement et/ou hebdomadairement sur chaque entrée et sortie ainsi que dans chaque étape du traitement. Le suivi a été réalisé à la fois en fonctionnement normal, en surcharge ainsi qu'en fonctionnement sans recirculation. La modélisation est quant à elle réalisée à l'aide du logiciel de simulation GPS-XTM. Les différentes étapes du traitement réel y sont représentées par un décanteur primaire (fosse) ainsi qu'un réacteur hybride, permettant la croissance fixe et suspendue (réacteur). Une étude de sensibilité a été réalisée pour cerner quels paramètres influencent le plus les prédictions du modèle. Celui-ci a par la suite été calé en comparant les résultats obtenus sur le pilote sous différents régimes à ceux simulés. Les résultats obtenus montrent que le système étudié élimine habituellement totalement l'azote ammoniacal, hormis lors des journées où la charge à traiter est particulièrement élevée. Les mesures de DCO ainsi que des MES effectuées à l'effluent du système ont également toujours été très faibles avec des moyennes de 16 et 3 mg/L (valeurs maximales de 58 et 6 mg/L), malgré des valeurs moyennes à l'entrée de 260 mg/L et 207 mg/L respectivement. Le modèle construit et calé montre également une bonne fidélité par rapport aux valeurs mesurées sur le pilote en sortie de chaque étape du traitement, avec une précision un peu moins bonne pour les nitrates. La modélisation semble donc pour le moment être un bon outil pour faciliter la compréhension et l'étude des performances d'un système de traitement résidentiel des eaux usées.
22

Adsorption et désorption d'ions phosphate et nitrate par des matériaux mésoporeux à base de silice fonctionnalisés avec des groupements ammonium

Saad, Rabih 13 April 2018 (has links)
Les impacts environnementaux majeurs de l'agriculture sont associés à l'eutrophisation des eaux de surface causée par un enrichissement excessif en nutriments (azote et phosphore) et à la contamination des eaux souterraines par les ions nitrate. L'objectif principal de ce projet de doctorat est l'utilisation de matériaux mésoporeux fonctionnalisés à base de silice pour l'adsorption des ions phosphate et nitrate contenus dans des solutions acqueuses synthétiques simulant les effluents d'origine agricole. Trois matériaux mésoporeux (MCM-41, MCM-48 et SBA -15) fonctionnalisés avec des groupements ammonium par la technique de greffage et de co-condensation ont été synthétisés, caractérisés puis testés en mode discontinu. Les conditions opératoires ont été optimisées aussi en mode discontinu. L'équilibre et la cinétique d'adsorption ont été modélisés. Finalement, l'adsorption des ions nitrate et phosphate a été menée en mode d'écoulement continu pour simuler les conditions opératoires à l'échelle industrielle.
23

Removal of nitrate from water and wastewater by ammonium-functionalized sba-16 mesoporous silica

Bui, Thi Hai Linh 19 April 2018 (has links)
La présence de composés azotés en excès peut conduire à la pollution de l'environnement et des problèmes de santé. Les ions nitrates sont les composés azotés les plus couramment rencontrés dans les eaux usées issues des activités humaines telles que l'agriculture. Par conséquent, l'élimination des ions nitrate dans les eaux souterraines et les eaux de surface ainsi que dans les eaux usées est d'une importance capitale. Actuellement, les principales méthodes appliquées pour l'élimination des ions nitrate, comprennent les méthodes biologiques et physico-chimiques. Cependant, ces traitements présentent des lacunes et des limites, telles que des conditions de réalisations coûteuses et complexes. Le procédé d'adsorption est considéré comme meilleur que les autres technologies de traitement des eaux usées, car sa conception est simple et son opération facile et économique, en plus de permettre de récupérer les ions nitrate. La technologie d'adsorption a été pratiquée avec succès dans l'élimination des ions nitrate avec divers matériaux comme adsorbants. Dans cette thèse, la silice mésoporeuse SBA-16 fonctionnalisée avec des groupements ammonium a été synthétisée et utilisée comme adsorbant potentiel pour l'élimination des ions nitrate dans l'eau potable et les eaux usées. Ceci est principalement dû à leur grande surface spécifique, leur méso-structure ordonnée et leur capacité de fonctionnalisation par différents groupes fonctionnels de surface. Le processus de fonctionnalisation de la SBA-16 avec des groupements amines (des groupes mono-, di- et tri-ammonium) peut être réalisé par deux méthodes: le procédé de greffage post-synthèse et par co-condensation. L'influence du pH de la solution, de la température d'adsorption, des ions compétitifs, de la charge en adsorbant et du rapport molaire organoalkoxysilane / silice a été étudiée par une série d'expériences d'adsorption en mode discontinu. Comme indiqué par les résultats de cette étude, la SBA-16 fonctionnalisée par greffage post-synthèse montre de meilleures performances en termes de pourcentage d'élimination des polluants et de capacité d'adsorption. La capacité d'adsorption maximale a été de 70,46 mg NO3-/ g d'adsorbant à une température de 5 ° C. Le processus d'adsorption a été très rapide et le temps d'équilibre a été atteint en moins de 5 minutes. La capacité d'adsorption a été augmentée en même temps la concentration initiale. L'enlèvement maximal pour les ions nitrate a été observé à pH 3 et au-delà de pH = 3, il n'y'a pas d'effet significatif sur cette élimination. La capacité d'adsorption augmente avec la modification du type d'amine, en passant du mono-, di - et tri-ammonium. En outre, les modèles d’adsorption tels que Freundlich, Temkin et Langmuir ont été appliqués aux isothermes obtenus. Les données d'équilibre d'adsorption sont en bon accord avec les modèles de Langmuir et de Temkin. De plus, les paramètres thermodynamiques ont été évalués pour le processus d'adsorption des ions nitrate. Les valeurs négatives des paramètres tels que l'enthalpie (AH °) et l'entropie (ΔSo) constatées pour l'ensemble des modèles d'isotherme, indiquent respectivement que la réaction est exothermique, et que la disposition aléatoire de l'adsorbat est en baisse à l'interface solide / liquide. / The presence of excess nitrogen (N) compounds can lead to environment pollutions and healthy problems. Also, nitrate ions are the commonly encountered N compounds in wastewater through human activities such as agriculture and human wastes. Therefore, removal of nitrate to diminish the concentration of nitrate in groundwater, surface water as well as in wastewaters is of prime importance. Normally, the major methods that have been applied for nitrate removal include biological and physicochemical technologies. However, current available treatments for nitrate removal have shortcomings and limitations such as high costs and complex operations. The adsorption process is considered better among other wastewater treatment technologies because of the simple design, easy and economical operation as well as allowing nitrate recovery. Adsorption technology has been found successful in nitrate removal by using various materials as adsorbents. In this thesis, ammonium-functionalized SBA-16 mesoporous silica was synthesized and used as potential adsorbent for nitrate removal in water and wastewater, which is due mainly to their large specific surface area, ordered meso-structure, and their functionalization ability by different surface functional groups. The functionalized SBA-16 process with amine groups (mono-, di- and tri ammonium silane) can be carried out through two methods: post synthesis grafting and co-condensation. The influence of solution pH, temperature, competitive ions, adsorbent loading and molar ratio organoalkoxysilane/silica was investigated by a series of batch adsorption experiments. As the results of this study, the mesoporous functionalized SBA-16 via post-synthesis grafting method exhibited higher performances in terms of percentage pollutant removal and adsorption capacities. The maximum adsorption capacity was found to be 70.46 mg NO3-/g adsorbent at temperature of 5oC. The adsorption was rapid at early stages of the treatment and the equilibrium was reached within 5 minutes. The capacity of adsorbent was increased with initial concentration. The maximum removal for nitrate was observed at pH of 3. The adsorption capacity increased with changing the amine type from mono-, di - to tri- ammonium silane groups. In addition, the parameters of adsorption process such as equilibrium adsorption isotherm and thermodynamic were investigated. The Freundlich, Langmuir and Temkin isotherm models were investigated. The adsorption equilibrium data were in good agreement with the Langmuir and Temkin isotherm models. The negative values of enthalpy (ΔH°) and entropy (ΔSo) were found for all of isotherm models. This indicates the exothermic character of nitrate adsorption process as well as the decrease in randomness at the solid/solution interface during the adsorption.
24

Opération adaptative des systèmes d'eau potable par le suivi de l'absorbance UV afin de minimiser l'exposition aux sous-produits de la désinfection

Beauchamp, Nicolas 10 July 2019 (has links)
Le suivi règlementaire des sous-produits de la désinfection (SPD) dans l’eau potable fournit généralement aux opérateurs des usines de production d’eau potable un portrait partiel de la performance du traitement en termes de SPD, étant donné la basse fréquence d’échantillonnage exigée. Une rétroaction plus fréquente sur les concentrations de SPD permettrait une optimisation des paramètres d’opération susceptible d’influencer l’enlèvement des précurseurs de SPD et la désinfection. Il importe alors d’avoir une méthode de suivi simple, rapide, et à fréquence élevée, voire en continu, des concentrations de SPD dans l’eau potable. L’absorbance UV différentielle (ΔA) est une méthode d’estimation des concentrations de SPD à coût faible, pouvant être effectuée rapidement et fréquemment, qui consiste à utiliser la différence entre une mesure de l’absorbance UV avant la chloration et une mesure de l’absorbance UV après la chloration pour prédire les concentrations de SPD. L’objectif de cette thèse est de développer une stratégie de suivi en continu de la formation des SPD par l’absorbance UV différentielle en usine afin de permettre une opération préventive et adaptative lors du traitement de l’eau. Cet objectif est divisé en deux sous-objectifs: comprendre pourquoi les relations SPD-ΔA ne sont pas universelles et identifier les stratégies favorisant leur généralisation et leur application à l’échelle réelle, et développer une stratégie d’opération adaptative et préventive du procédé de coagulation-floculation, utilisant comme rétroaction l’absorbance UV-visible, afin de réduire les concentrations de SPD à l’usine et en réseau. À cette fin, un premier essai a été fait afin de vérifier la possibilité d’établir des relations SPD-ΔA valide à l’échelle réelle. Ensuite, une stratégie de coagulation à l’échelle réelle utilisant l’absorbance UV à 254 nm des eaux brutes et décantées a été testée. En parallèle, une série de jar-tests et d’essais de chloration faits sur 8 eaux brutes différentes a permis de construire une base de données sur la coagulation de la matière organique et des précurseurs des SPD, permettant de comparer les résultats obtenus en laboratoire à ceux obtenus à l’échelle réelle. Cette même base de données a aussi servi à établir des relations SPD-ΔA plus largement applicables et à formuler des recommandations sur l’approche à adopter pour généraliser et utiliser ces relations. Les résultats des essais à l’échelle réelle montrent qu’il est possible d’établir des relations SPD-ΔA autant pour des sous-produits règlementés (trihalométhanes (THM) et acides haloacétiques (AHA)) que pour des sous-produits émergents (haloacétonitriles (HAN), halocétone (HK), et chloropicrine (CPK)) en utilisant l’absorbance UV différentielle à une seule longueur d’onde (272 nm), mais que ces relations varient dans le temps en fonction des paramètres physico-chimiques de l’eau brute et des paramètres d’opération des procédés. L’absorbance UV avant chloration demeure malgré tout un bon indicateur de la concentration de précurseurs de SPD. Ainsi, une stratégie de coagulation basée sur une dose stœchiométrique d’alun par rapport à l’absorbance UV à 254nm de l’eau brute (dose d’alun/UV254 de l’eau brute) a été développée à l’échelle réelle. Les résultats de l’essai de la stratégie à l’échelle réelle et des jar-tests concordent et confirment que l’utilisation d’une dose stœchiométrique d’alun définie permet de maximiser l’enlèvement de l’absorbance UV et des précurseurs dans une situation de qualité de l’eau variable quotidiennement et saisonnièrement. L’utilisation de l’absorbance UV différentielle à plusieurs longueurs d’onde, en plus de l’utilisation de l’absorbance avant chloration, permet d’améliorer les prédictions des relations empiriques SPD-ΔA et de généraliser leur application. En effet, les résultats des jar-tests et des essais de chloration ont montré que ces relations sont applicables à des eaux chlorées ayant des caractéristiques physico-chimiques variées. Spécifiquement, les concentrations de THM semblent mieux prédites en utilisant l’absorbance avant chloration à 270 nm, ΔA à 270 nm et ΔA à 425 nm, l’acide dichloroacétique en utilisant l’absorbance avant chloration à 250nm, ΔA à 250 nm et ΔA à 425 nm, et l’acide trichloroacétique en utilisant l’absorbance avant chloration à 255 nm, ΔA à 255nm et ΔA à 425 nm. L’utilisation de l’absorbance différentielle à plusieurs longueurs d’onde devra être expérimentée à l’échelle réelle dans des recherches futures, entre autres en utilisant des sondes de mesure de l’absorbance en continu. / Regulatory sampling of drinking water for the control of disinfection by-products (DBPs) gives a partial depiction of the performance of a drinking water system in terms of DBPs, given the usually low sampling frequency required. A more frequent feedback on DBP concentrations would allow optimisation of the operation of the treatment processes responsible for the removal of DBP precursors. It is therefore important to develop a simple, rapid and high frequency or even continuous monitoring method for DBPs. Differential UV absorbance (ΔA) is a method, consisting of the use of the difference between the absorbance of a sample before chlorination and after chlorination to predict DBP concentrations that can provide such a feedback rapidly and frequently. The main goal of this thesis is to develop a continuous DBP monitoring strategy using differential UV absorbance in order to achieve a preventive and adaptive operation of water treatment processes. This goal is divided into two sub-objectives : to understand why DBP-ΔA relationships are not universal and to identify ways to generalize their application in full-scale water treatment facilities, and to develop a preventive and adaptive operation strategy of the coagulation-flocculation process, using UV absorbance as a feedback, in order to reduce DBP concentrations at the plant and in the distribution network. To reach these goals, atrial was made to assess the possibility of establishing DBP-ΔA relationships at a full-scale treatment plant. Then, a coagulation strategy using UV absorbance at 254 nm of the raw and settled waters was tested to assess its capacity to reduce DBP concentrations. At the same time, jar-tests and chlorination experiments were conducted on 8 different water sources to build a database on the coagulation of DBP precursors. These results were compared with the full-scale coagulation strategy. The database was also used to establish DBP-ΔA relationships applicable to waters with a wide range of physicochemical characteristics and to formulate recommendations on the approach to take to generalize and use these relationships. The results of the full-scale trials show that it is possible to establish DBP-ΔA relationships for both regulated (trihalomethanes (THM) and haloacetic acids (HAAs)) and unregulated (haloacetonitriles (HANs), haloketones (HKs) and chloropicrin (CPK)) DBPs using differential UV absorbance at one wavelength (272 nm), but that these relationships vary with the raw water physicochemical characteristics and with the operation parameters of the treatment process. Nonetheless, UV absorbance before chlorination remains a good surrogate of the concentration of DBP precursors. A coagulation strategy based on a stoichiometric alum dose related to UV absorbance at 254 nm (alum/UV254) was therefore developed at full-scale. Results from the full-scale trials and the jar-tests are coherent and confirm that using a stable stoichiometric dose maximises the removal of UV absorbance and DBP precursors despite daily and seasonal variations of raw water quality and natural organic matter content. The use of differential UV absorbance at multiple wavelength made it possible to improve the predictive capacity of empirical DBP-ΔA relationships and to generalize their application. Indeed, results from the jar-tests and chlorination experiments showed that these relationships are applicable to chlorinated waters with very different physicochemical characteristics. Specifically, THM concentrations seem to be better predicted using pre-chlorination absorbance at 270nm, ΔA at 270nm and ΔA at 425nm, dichloroacetic acid using pre-chlorination absorbance at 250nm, ΔA at 250nm and ΔA at 425nm, and trichloroacetic acid using pre-chlorination absorbance at 255nm, ΔA at 255nm and ΔA at 425nm. The use of differential absorbance at multiple wavelengths, especially using online absorbance probes, should be tried in a full-scale water treatment facility in future research.
25

Suivi de systèmes de décantation à flocs lestés

Mpode Nkoum, Franck Dieudonné 17 April 2018 (has links)
Pour différentes raisons dont l'amélioration de la santé publique et un souci économique, il est important d'optimiser le fonctionnement des usines de production d'eau potable. Les présents travaux avaient pour objectif l'optimisation d'un système de coagulation, floculation et décantation à flocs lestés qui constitue la première étape de nombreux systèmes conventionnels de traitement d'eau actuels. Le premier sous-objectif de ce projet a porté sur le test d'un outil expérimental, le jartest, réalisé avec du microsable. Cette étude a été réalisée à l'usine de traitement d'eau (UTE) de Québec secteur centre. Le second objectif a visé le suivi ainsi que le développement d'outils d'analyse de données et de performance de deux (2) systèmes réels de décantation à flocs lestés. Dans la première partie de l'étude, les résultats obtenus montrent que les absorbances UV (Abs. UV) des eaux décantées (ED) mesurées en jartests représentent bien les performances en usine mais que cela n'est pas le cas en termes de turbidite. Ces résultats montrent aussi que la reproductibilité des jartests est bonne en termes d'Abs. UV mais qu'elle est mauvaise en termes de turbidite. L'intérêt pratique de tels jartests est donc pour l'instant limité. La seconde étude a été un suivi des systèmes de décantation des UTE de Québec secteur centre et de Charny pendant environ un an. L'analyse des données collectées révèle que l'abattement de la turbidite à l'ED dépend de la turbidite à l'eau brute (EB). qui varie très significativement pendant l'année. Le suivi des comptes de bactéries sporulantes aérobies (BSA) montre que la décantation à flocs lestés permet un abattement des BSA d'environ 1 log, ce qui indique un enlèvement significatif des parasites dans cette première étape de traitement. D'autre part, une modélisation par réseaux neuronaux qui permet une prédiction du dosage d'alun et de chaux a été réalisée. Cet outil pourrait, dans le futur, assister les opérateurs dans les ajustements de dosages de produits chimiques. Une approche pour mesurer la robustesse d'un système de traitement d'eau est également proposée. Cette approche est basée sur un indicateur de performance existant qui est mis en relation avec un nouvel indicateur qui caractérise la variabilité de la qualité de l'affluent. Ce dernier indicateur permet aussi de comparer différentes sources d'eau. Cette approche d'évaluation de la robustesse est appliquée et testée sur l'abattement de la turbidite dans les décanteurs à flocs lestés des deux UTE considérées dans la présente étude.
26

Perceptions des goûts et des odeurs dans un système de distribution d'eau potable

Garemi, Laurence 11 April 2018 (has links)
Le traitement de l'eau permet à tout un chacun d'avoir de l'eau potable simplement en ouvrant le robinet. Pourtant, un nombre grandissant de consommateurs préfère boire de l'eau embouteillée. Les raisons de ce choix sont essentiellement esthétiques et en lien étroit avec les goûts et les odeurs. Cette préférence se manifeste notamment parmi les citoyens de Sainte-Foy, ville dont le réseau est alimenté par le fleuve Saint-Laurent. La présente étude a pour objectifs de comprendre ce qui peut engendrer ces problèmes organoleptiques. Pour ce faire, un suivi des paramètres physicochimiques et un profil des qualités esthétiques de l'eau ont été effectués, au moyen d'un groupe témoin de dégustation (panel), en plusieurs points du réseau de la ville de Sainte-Foy ainsi qu'à l'usine de traitement. Or, les principaux problèmes qui ont été retenus résident dans les goûts et les odeurs de chlore. Par conséquent, la mise en relation des pôles analyses et perceptions devait permettre de comprendre pourquoi ces problèmes étaient présents et comment ils évoluaient. Ainsi, de cette opération, la seule certitude mise en lumière se retrouve en début de réseau où il est nettement clair que l'acide hypochloreux est responsable des odeurs de chlore, et ce, durant toute l'année. En ce qui concerne les autres points du réseau, des composés autres que ceux étudiés dans cette recherche interviendraient de 40 à 50 % dans la responsabilité de ces odeurs de chlore. Le reste se partage entre l'acide hypochloreux et la trichloramine. En conséquence, les problèmes de goût et d'odeur seraient dus à une contribution partagée entre plusieurs composés présents dans l'eau. Cependant, tous ces composés n'ont pas fait l'objet de cette recherche.
27

Développement d'un système de traitement des eaux de ruissellement routier par marais épurateur adapté et lit filtrant réactif

Morteau, Bertrand 20 April 2018 (has links)
Les eaux de ruissellement routier constituent une problématique due principalement à la circulation routière. Dans certains pays des sels de déglaçage sont répandus sur les routes pendant l’hiver et ceci ajoute d’autres contaminants à cette problématique. Pour traiter ces eaux de ruissellement il a été proposé d’utiliser un marais épurateur construit (MEC) couplé à un lit filtrant. Étant donné le taux de salinité élevé de ces eaux, il a également été suggéré de se servir d’espèces halophytes (plantes qui accumulent les sels) pour le MEC. Le lit filtrant serait composé de calcite, un minéral qui adsorbe le phosphore. L’un des objectifs de cette étude est de déterminer la faisabilité d’un traitement par MEC avec des espèces halophytes en évaluant d’abord les conditions optimales nécessaires pour la croissance des espèces sélectionnées (Atriplex patula, Salicornia europaea, Spergularia canadensis, Typha augustifolia), et leur capacité d’accumulation des sels. Des essais-pilotes menés en serres sont ensuite réalisés à partir des valeurs optimales de ces facteurs. L’autre objectif est d’étudier la capacité d’adsorption par la calcite en fonction de la concentration de phosphore initiale, du temps et de la présence ou non de métaux dans l’eau. Ces caractéristiques nous permettent de définir les paramètres d’essais d’adsorption menés dans des colonnes qui nous permettront de formuler des recommandations quant à la conception du lit filtrant. Les essais-pilotes ont permis d’atteindre des taux d’enlèvement de chlorure et de sodium allant jusqu’à 97 % selon l’espèce halophyte considérée. Les plus hauts taux d’enlèvement ont été constatés dans le cas des unités pilotes d’Atriplex patula. Il a été observé que les adsorptions de phosphore par la calcite ont atteint 1,7 mg P/g de calcite. Les résultats des essais en colonne ont présenté des réductions des concentrations allant jusqu’à 64 %. Cependant le traitement pourrait être meilleur à grande échelle. Des suggestions de recherches futures pour l’amélioration de ces traitements sont présentées en conclusion. / Road runoff is a worldwide problematic, mainly due to metals and hydrocarbon released by cars. Certain Nordic countries like Canada add other contaminants to this chemical mixture by spreading de-icing salts on their roads during winter. With the goal of treating high salt concentration road runoff, it has been proposed to use a constructed wetland coupled with a packed bed filter. Halophytic plants (plants able to accumulate salts) have been suggested as the constructed wetland vegetation. The packed bed filter would be filled with calcite, a phosphorus adsorbant material. The first objective of this thesis was to determine the feasibility of a treatment by constructed wetlands with halophytic plants. Our methodology consisted in evaluating the optimal conditions (1) for the growth of the selected species (Atriplex patula, Salicornia europaea, Spergularia canadensis and Typha augustifolia) and (2) for NaCl accumulation. Those results have been used to design 16 pilot tests by our laboratory. The second objective was to study the phosphorus adsorption capability of calcite as a function of the initial phosphorus concentration, time, temperature and the presence of metals. Adsorption was then tested in column tests. Constructed wetland pilots resulted in chloride and sodium reduction rates from 0 to 97 % depending on the species. The calcite presented adsorptions of active phosphorus up to 1.7 P/g mg of calcite. The results of the column tests allowed a 64 % removal of phosphorus. Saturation of calcite has been reached in a few hours. Treatment could be improved on a large scale device. It is recommended to place the packed bed filter after the MECA and to the follow the design parameters: 1) nutrition complement in the substrate, 2) water level close to the soil surface, 3) a residence time of one week and 4) different basins to be able to optimize the phytoremediation capabilities of the selected species. Packed bed filter should have a residence time of two hours and a calcite of 0.317 cm granulometry. Suggestions for future research to improve treatment system are presented in the conclusion section.
28

Développement d'une démarche pour améliorer la désinfection secondaire et la qualité de l'eau potable au Nunavik : projet pilote à Kangiqsualujjuaq

Garcia Sanchez, Cristian Ruben 14 September 2022 (has links)
La population des villages du Nunavik, au nord du Québec, a généralement accès à l'eau potable municipale à partir de réservoirs domestiques. L'eau brute, qui vient généralement d'une source de surface, est amenée à l'usine de traitement municipale pour être traitée avec des rayons ultraviolets et du chlore, puis distribuée à la communauté par des camions citernes. Une campagne d'échantillonnage de l'eau réalisée en 2019 dans trois villages du Nunavik a mis en évidence que la désinfection par chloration n'est pas suffisante pour assurer une protection adéquate pendant la distribution et le stockage domestique de l'eau. L'objectif de ce mémoire de maîtrise a été de développer une stratégie pour améliorer la désinfection secondaire de l'eau par chloration au Nunavik, en utilisant comme étude de cas le village de Kangiqsualujjuaq. Pour ce faire, un portrait de la qualité de l'eau entre la source et les robinets a été dressé, avec une emphase sur le chlore résiduel et les sous-produits de désinfection. Avec ce portrait, une démarche a été mise au point pour identifier les quantités adéquates de chlore permettant d'obtenir des concentrations de désinfectant résiduel répondant aux standards internationaux, tout en limitant la génération de sous-produits de désinfection. Ces doses adéquates ont été obtenues à l'aide simulations de chloration en laboratoire réalisées avec des eaux de la communauté collectées en 2020 et en 2021. Avec les informations obtenues sur le terrain et dans les expériences de laboratoire, une base de données d'aide à la décision a été développée pour permettre aux responsables de la communauté de faire des choix éclairés quant à l'application du chlore pour la désinfection secondaire de l'eau. / The inhabitants of the villages of Nunavik, in northern Quebec, have generally access to municipal water stored in their domestic tanks. Municipal drinking water is commonly produced in a treatment plant supplied by a surface source, where ultraviolet light and chlorination are applied. Treated water is then distributed to the community by tanker trucks. A water sampling campaign conducted in 2019 in three Nunavik villages highlighted that secondary disinfection by chlorination is not sufficient to ensure adequate protection during water distribution and storage. The objective of this project was to develop a strategy to improve the secondary disinfection by chlorination, using the village of Kangiqsualujjuaq as case study. A profile of the water quality from source to tap was drawn up, with an emphasis on residual chlorine and disinfection by-products. Based on this portrait, a strategy was implemented to identify adequate chlorine doses to achieve disinfectant residual concentrations that meet international standards, while limiting the generation of disinfection by-products. These adequate doses were obtained using laboratory simulations of chlorination performed with community waters collected in 2020 and 2021. Based on the collected information, a decision support database was developed to allow community managers to make informed choices about the application of chlorine for secondary disinfection of water.
29

Capture passive du phosphore d'une eau usée municipale en contexte de biofiltration

Roy-Dumesnil, Gabriel 24 April 2018 (has links)
En concentration excessive, le phosphore rejeté à l'environnement favorise la croissance anormalement rapide de la flore aquatique. Des efforts doivent donc être faits pour développer des traitements qui permettront d'abaisser la concentration des rejets à des valeurs pouvant être aussi basses que 0,3 mgPtot/L. En ce sens, des travaux de recherche ont été réalisés. La méthodologie utilisée est basée sur l'utilisation d'un média filtrant constitué de broyure de bois activée imprégnée d'hydroxyde de fer à sa surface. Des essais en colonne ont été réalisés à partir de ce média filtrant. Opérées en immersion durant plus de 250 jours, des colonnes ont été alimentées avec une eau synthétique dopée en phosphore. Par ces essais, il a été mis en évidence que les colonnes opérées en milieu anaérobie sont plus efficaces que les colonnes opérées en aérobie. L'absence d'oxygène entraine une chute progressive du potentiel d'oxydoréduction. Lorsqu'il atteint des valeurs de l'ordre de -100mV, le fer en surface de la broyure se réduit et passe de la forme Fe³⁺ à la forme Fe²⁺. La forme Fe²⁺ étant plus soluble que la forme Fe³⁺, il y a donc une augmentation de la concentration en fer dissout. Appelé dissolution réductive, ce phénomène lent permet la complexation du fer solubilisé avec les ions phosphates en solution. C'est la combinaison de l'adsorption et de la complexation du fer qui permet d'obtenir un média performant. Sur une période de 291 jours, la colonne opérée en anaérobie a permis de maintenir à 85% l'enlèvement du phosphore. Puisque le phénomène de dissolution réductive entraine des relargages de fer et de phosphate ferrique à la sortie de la colonne, le contrôle de ces relargages par l'ajout d'une zone aérobie permet une hausse de la performance globale d'enlèvement du phosphore pour un % d'enlèvement global de 95%.
30

Propriétés des membranes homogènes composées de SPEEK/PI pour la séparation de la vapeur d'eau

Ceperkovic, Olivera 12 April 2018 (has links)
Des membranes homogènes et danses préparées à partir d'un mélange de différents pourcentages massiques en polyéther-éther-cétone solfoné (SPEEK) et pollyimide (PI) puis de SPEEK-Na et PI ont été étudiées. Ces membranes ont montré une augmentation de la capacité d'absorption de l'acide acétique et surtout de l'eau. Cette augmentation de l'absorption est suivie d'une augmentation importante de la séparation acide acétique et eau en phase vapeur et d'une légère baisse de la perméabilité due à une diffusion du coefficient de diffusion par rapport aux membranes fabriquée avec du PI pur. Les résultats obtenus montrent que la teneur en composés organiques (matière carbonée) peut être réduite à moins de 140 ppm dans le perméat, ce qui correspond à une pureté de l'eau de 99,6 du perméat après la séparation membranaire. Il a été découvert que les propriétés physiques et séparatives de ces membranes dépendent du degré de sulfonation du SPEEK. Les membranes ont été caractérisées au moyen d'analyse élémentaires, de méthodes thermogravimétriques (DSC et DTG), de FTIR et par SEM.

Page generated in 0.1209 seconds