• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Composés pharmaceutiques et eaux usées urbaines. I, Analyse bibliographique. II, Effet de deux antibiotiques de type macrolide sur les boues activées / Pharmaceutical substances and urban wastewater. I, Literature survey. II, Effect of two macrolide antibiotics on activated sludge

Alighardashi, Abolghasem 06 November 2007 (has links)
Les principaux points de dispersion des composés pharmaceutiques dans l’environnement sont les stations d’épuration des eaux usées. A partir de l’analyse de la base de données constituée au cours de ce travail, les quantités de ces composés trouvées dans ces installations peuvent être directement liées à celles de médicaments consommés. La situation, quant à leur élimination de la phase liquide, est contrastée. Ainsi certaines hormones sont éliminées avec des rendements importants mais d’autres ne le sont pas du tout. Les produits radio-contrastants à base d’halogènes et notamment d’iode, soupçonnés d’être cancérogènes, sont majoritairement non biodégradables. Les effets d’antibiotiques sur les boues activées ont été plus particulièrement étudiés du fait de leur consommation, de leur présence dans les milieux aquatiques et de leur action spécifique sur les bactéries. Des expériences permettant d’évaluer la toxicité de ces principes actifs ont été conduites sur des boues activées en réacteur discontinu, avec un suivi de la morphologie des flocs par analyse d’images de microscopie optique. Il a été ainsi observé que, selon la concentration utilisée, l’érythromycine et la tylosine, macrolides largement utilisés respectivement en médecine humaine et vétérinaire, inhibent l’élimination de la pollution organique et dégradent l’ensemble de la biomasse. Ces antibiotiques ont également un effet néfaste sur le métabolisme de l’azote, qu’il s’agisse de l’ammonification, de la nitritation et de la nitratation / The main sources of dispersion of pharmaceutical substances in environment are wastewater treatment plants. Based on the analysis of the database built during this project, the amounts of pharmaceutical substances found in plants can be directly related to the amount consumed. Regarding their elimination from the liquid phase, the situation is very disparate. The elimination yield of hormones can be null or very large. Halogen-based X-ray contrast media (or AOX) are mainly non biodegradable. The effects of antibiotics on activated sludge have been especially investigated due to their consumption, presence in aquatic environment and specific action on bacteria. Batch tests have been performed to evaluate the toxicity of these active pharmaceutical ingredients on activated sludge. Sludge morphology was monitored by analysis of light microscopy images. Depending upon the applied dose, erythromycin and tylosin, two macrolides widely used for human and animal health care, inhibit the elimination of organic pollution and damage biomass. These antibiotics have a deleterious effect on ammonification, nitritation and nitratation
2

Relations entre la variabilité de la pollution des eaux usées urbaines et les contextes géographiques, socio-économiques et culturels au Bénin et en France / Relationship between the variability of urban wastewater pollution and the geographical, socio-economic and cultural contexts in Benin and France

Atinkpahoun, Nelly Chrystelle Houéfa 27 June 2018 (has links)
Le non traitement et/ou le traitement inadéquat des eaux usées constitue l’une des causes principales de la pollution des ressources en eau. Pour y remédier il importe de mettre en place des infrastructures d’assainissement fonctionnelles et d’optimiser leur performance. Améliorer les stratégies de contrôle est l’action principale de cette optimisation, et la modélisation en est l’un des défis à relever. Pour ce faire, les présents travaux visent à fournir des connaissances spécifiques sur la variabilité des eaux usées urbaines de Cotonou et du Grand-Nancy et de disposer de données expérimentales qui serviront à court ou moyen termes au développement de modèle de génération d’eaux usées virtuelles. Les travaux ont consisté à échantillonner pendant plusieurs mois des eaux usées urbaines de temps sec en entrée de STEP (quartier vie-nouvelle à Cotonou et commune de Maxéville dans le Grand-Nancy) à travers des prélèvements horaires sur 24 h. A Cotonou, des prélèvements ont été aussi faits dans les collecteurs. In-situ ont été prises les mesures du débit. Au laboratoire sont faites sur les échantillons des analyses spécifiques de dosage des polluants. Une simulation des variabilités des eaux usées est également faite au moyen de modèle de génération des eaux usées virtuelles. Des travaux, il ressort les constats ci-après : - les débits en entrée de STEP (Grand-Nancy) présentent une variabilité journalière avec trois pics respectivement vers 10 h, 14 h et 21 h les jours ouvrés et caractérisée pendant les jours de week-end par une diminution de 2% (les samedis) et 9% (les dimanches) avec un retard de 2 h dans l’apparition du premier pic de la journée ; - les eaux usées de Cotonou présentent une plus forte pollution par rapport aux eaux usées urbaines du Grand-Nancy bien que l’Equivalent Habitant raccordé à La STEP de Cotonou (≈ 1 200 EH) soit de loin plus faible que celui du Grand-Nancy (≈ 275 000 EH) ; - néanmoins on note une plus forte conductivité électrique des eaux usées du Grand-Nancy ainsi qu’un excès en Europium plus élevé comparativement à ceux des eaux usées de Cotonou ; - la variabilité journalière pour l’ensemble des paramètres dans les bassins est très prononcée, exception faite pour le pH qui présente une similarité dans les deux contextes géographiques ; - le modèle de génération des eaux usées virtuelle en développement intègre bien le mode de vie du bassin de collecte du Grand-Nancy et a montré des simulations des variations du débit et de la pollution similaires aux variations expérimentales réelles ; - les recherches et le développement du modèle se poursuivent pour étendre ce dernier aux métaux lourds et l’appliquer aux bassins de collecte. Le modèle permet de combler des lacunes de données, de donner des fréquences plus élevées à la dynamique des données, de créer divers scénarii de perturbation de variabilité des eaux usées en situation virtuelle et de faire des prédictions de situations réelles pour une amélioration des performances des STEP / Untreated and / or inadequate treatment of wastewater is one of the main causes of water resource pollution. To remedy this it is important to establish functional sanitation infrastructure and optimize their performance. Improving control strategies is the main action of this optimization, and modeling is one of the challenges. To do this, the present work aims to provide specific knowledge on the variability of urban wastewater of Cotonou and Grand Nancy and to have experimental data to be used for short or medium term for the development of a generation model of virtual wastewater. The work consisted in sampling for several months the urban wastewater at the entrance of STEP (« Vie-Nouvelle » city in Cotonou and Maxéville in Grand-Nancy) through hourly samples over 24 hours. In Cotonou, samples were also taken from the collectors. In-situ were taken measurements of the flow. In the laboratory are made on samples specific analyses of pollutant dosing. Simulation of wastewater variability is also done using a virtual wastewater generation model. From the works, the following observations emerge: - flows from STEP (Grand-Nancy) show daily variability with three peaks respectively at around 10 am, 2 pm and 9 pm on weekdays and characterized on weekend days by a 2% decrease (Saturdays) and 9% (Sundays) with a delay of 2 hours in the appearance of the first peak of the day ; - Wastewater of Cotonou exhibit greater pollution than urban wastewater of Grand-Nancy although Population Equivalent connected to the STEP of Cotonou (≈ 1,200 PE) is far lower than that of Grand-Nancy (≈ 275,000 PE) ; - Nevertheless, there is a higher electrical conductivity of wastewater from Greater Nancy and a higher excess of Europium compared to that of Cotonou wastewater ; - The daily variability for all the parameters in the catchments is very pronounced, except for the pH which has a similarity in the two geographical contexts ; - the virtual wastewater generation model is well integrated with the lifestyle of the Grand-Nancy catchment basin and showed simulations of flow and pollution variations similar to actual experimental variations ; - research and model development is continuing to extend the model to heavy metals and apply it to collection basins ; The model allows to bridge data gaps, giving higher frequencies to dynamic data, create various wastewater variability distubance scenarios in virtual situation and make real situations predictions for improved performance of WWTP
3

Etude d'un procédé d'ozonation catalytique pour l'élimination des micropolluants dans les effluents urbains / Etude d’un procédé d’ozonation catalytique pour l’élimination des micropolluants dans les effluents urbains

Crousier, Claire 10 December 2015 (has links)
Les travaux menés au cours de cette thèse ont pour objectif d’étudier l’applicabilité du procédé d’ozonation catalytique TOCCATA® au traitement avancé d’eaux résiduaires urbaines pour le contrôle des émissions en micropolluants. Ce travail couvre la détermination des propriétés physico-chimiques, structurelles et de réactivité de deux catalyseurs et l’optimisation de leur conditionnement pour le procédé d’ozonation catalytique. La caractérisation hydrodynamique du réacteur à co-courant ascendant triphasique en lit fixe utilisé pour la mise en œuvre du procédé a été également réalisée. Les processus élémentaires impliqués dans le procédé ont ensuite été étudiés séparément : transfert gaz-liquide, adsorption, ozonation simple et interaction ozone/matériau. Enfin l’ozonation catalytique a été étudiée vis-à-vis de l’élimination de la matière organique des eaux usées réelles. L’ozonation catalytique se montre moins sélective que l’ozonation simple et améliore le procédé en termes de transfert d’ozone et d’élimination du carbone organique. Des mécanismes et des lois cinétiques pour chacun des processus élémentaires ont été déterminés et une loi de vitesse globale de premier ordre pour le procédé d’ozonation catalytique est proposée. L’étude de l’influence de différentes variables opératoires a été effectuée en vue de l’optimisation du procédé. L’investigation a ensuite été élargie à l’élimination de micropolluants spécifiques (carbamazépine, diuron, kétoprofène, diclofénac, naphtalène) appliquée à des eaux synthétiques, ainsi qu’à des eaux résiduaires urbaines réelles. La plupart des composés sont dégradés après application d’une faible dose d’ozone par le procédé. L’étude de leurs propriétés et de leur affinité avec le système d’ozonation catalytique a permis d’expliquer leurs comportements. / This thesis aimed to study the application of the TOCCATA® catalytic process to urban wastewaters treatment in order to control micropolluant emissions. This work first focused on physico-chemical, structural and reactional properties of two catalysts and on the optimization of their conditioning for the use in the catalytic process. The hydrodynamic characterisation of the fixed bed triphasic co-current upflow reactor used for this study was realized. Elementary processes involved in the process were studied separately: gas-liquid transfer, adsorption, single ozonation, ozone/catalyst interactions. Catalytic ozonation was then investigated for the elimination of organic matter contained in real urban wastewaters. Catalytic ozonation appeared to be less selective than single ozonation and to improve the process in terms of ozone transfer and organic carbon removal efficiency. Mechanisms and kinetic laws were determined for each elementary process and a global first order kinetic law was proposed for catalytic ozonation. The study of various operating conditions (liquid and gas flows, ozone dose …) was conducted in order to optimize the process efficiency.Investigations were then extended towards specific micropollutants elimination (carbamazepine, diuron, ketoprofen, diclofenac, naphtalene) onto synthetic waters as well as real urban wastewaters. Most of the compounds were eliminated with low dose ozonation by the TOCCATA® catalytic ozonation process. The properties of the micropollutants and their affinities with the catalytic ozonation system were studied in order to explain their behaviours.

Page generated in 0.059 seconds